1.
Nano Lett ; 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39361544

RESUMO

Metasurfaces provide an ultrathin platform for compact, real-time polarimetry. However, their applications in polychromatic scenes are restricted by narrow operating bandwidths that causes spectral information loss. Here, we demonstrate full-color polarization imaging using an achromatic polarimeter consisting of four polarization-dependent metalenses. Leveraging an intelligent design scheme, we achieve effective arbitrary phase compensation and multiobjective matching with a limited database. This system provides broadband achromaticity across wavelengths from 450 to 650 nm, resulting in a relative bandwidth of approximately 0.364 for full Stokes imaging. Experimental reconstruction errors for wavelengths of 450, 550, and 650 nm are 7.5%, 5.9%, and 3.8%, respectively. Performance is evaluated based on both achromatic bandwidth and crosstalk, with our design achieving three times the performance of the current state-of-the-art. The full-color, full-polarization imaging capability of the device is further validated with a customized object. The proposed scheme advances polarization imaging for practical applications.

2.
J Biophotonics ; 17(9): e202400052, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38952197

RESUMO

A Mueller matrix polarimetry system at 532 nm wavelength is developed for noninvasive glucose sensing in turbid media such as human's fingertip. The system extracts mean absorbance and anisotropic properties, demonstrated numerically and experimentally with phantom glucose samples. It is found that mean absorbance ( A e ), depolarization index (Δ), and linear dichroism (LD) show linear variation with glucose concentration 100-500 mg/dL. In addition, LightTools simulations indicate proportional scaling of scattering effects with A e , Δ, and LD. Real-world tests on fingertip show a strong correlation between these properties and blood glucose levels with a mean absolute relative deviation (MARD) of 12.56% and a correlation coefficient (R2) of 0.875 in prediction by a neural network (NN) model, highlighting the advantages of Mueller matrix in extracting more parameters related to blood glucose.


Assuntos
Dedos , Humanos , Anisotropia , Glicemia/análise , Redes Neurais de Computação , Glucose , Absorção de Radiação
3.
Sci Rep ; 14(1): 17714, 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39085453

RESUMO

In recent years, handheld and portable terahertz instruments have been in rapid development for various applications ranging from non-destructive testing to biomedical imaging and sensing. For instance, we have deployed our Portable Handheld Spectral Reflection (PHASR) Scanners for in vivo full-spectroscopic imaging of skin burns in large animal models in operating room settings. In this paper, we debut the polarimetric version of the PHASR Scanner, and describe a generalized calibration technique to map the spatial and spectral dependence of the Jones matrix of an imaging scanner across its field of view. Our design is based on placement of two orthogonal photoconductive antenna (PCA) detectors separated by a polarizing beam splitter in the PHASR Scanner housing. We show that as few as three independent measurements of a well-characterized polarimetric calibration target are sufficient to determine the polarization state of the incident beam at the sample location, as well as to extract the Jones propagation matrix from the sample location to the detectors. We have tested the accuracy of our scanner by validating polarimetric measurements obtained from a birefringent crystal rotated to various angles, as compared to the theoretically predicted response of the sample. This new version of our PHASR scanner can be used for high-speed imaging and investigation of heterogeneity of polarization-sensitive samples in the field.

4.
Sensors (Basel) ; 24(13)2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39001044

RESUMO

The generation of terahertz radiation via laser-induced plasma from two-color femtosecond pulses in air has been extensively studied due to its broad emission spectrum and significant pulse energy. However, precise control over the temporal properties of these ultra-broadband terahertz pulses, as well as the measurement of their polarization state, remain challenging. In this study, we review our latest findings on these topics and present additional results not previously reported in our earlier works. First, we investigate the impact of chirping on the fundamental wave and the effect of manipulating the phase difference between the fundamental wave and the second-harmonic wave on the properties of generated terahertz pulses. We demonstrate that we can tune the time shape of terahertz pulses, causing them to reverse polarity or become bipolar by carefully selecting the correct combination of chirp and phase. Additionally, we introduce a novel technique for polarization characterization, termed terahertz unipolar polarimetry, which utilizes a weak probe beam and avoids the systematic errors associated with traditional methods. This technique is effective for detecting polarization-structured terahertz beams and the longitudinal component of focused terahertz beams. Our findings contribute to the improved control and characterization of terahertz radiation, enhancing its application in fields such as nonlinear optics, spectroscopy, and microscopy.

5.
Bioinformatics ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38830086

RESUMO

MOTIVATION: Imaging Mueller polarimetry has already proved its potential for biomedicine, remote sensing and metrology. The real-time applications of this modality require both video rate image acquisition and fast data post-processing algorithms. First, one must check the physical realizability of the experimental Mueller matrices in order to filter out non-physical data, ie to test the positive semi-definiteness of the 4 × 4 Hermitian coherency matrix calculated from the elements of corresponding Mueller matrix pixel-wise. For this purpose, we compared the execution time for the calculations of i) eigenvalues, ii) Cholesky decomposition, iii) Sylvester's criterion, and iv) coefficients of the characteristic polynomial (two different approaches) of the Hermitian coherency matrix, all calculated for the experimental Mueller matrix images (600 pixels × 700 pixels) of mouse uterine cervix. The calculations were performed using C ++ and Julia programming languages. RESULTS: Our results showed the superiority of the algorithm iv) based on the simplification via Pauli matrices over other algorithms for our dataset. The sequential implementation of latter algorithm on a single core already satisfies the requirements of real-time polarimetric imaging. This can be further amplified by the proposed parallelization (e.g., we achieve a 5-fold speed up on 6 cores). AVAILABILITY AND IMPLEMENTATION: The source codes of the algorithms and experimental data are available at https://github.com/pogudingleb/mueller_matrices.

6.
Micromachines (Basel) ; 15(6)2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38930764

RESUMO

Polarimetry is used to determine the Stokes parameters of a laser beam. Once all four S0,1,2,3 parameters are determined, the state of polarisation is established. Upon reflection of a laser beam with the defined S polarisation state, the directly measured S parameters can be used to determine the optical properties of the surface, which modify the S-state upon reflection. Here, we use polarimetry for the determination of surface anisotropies related to the birefringence and dichroism of different materials, which have a common feature of linear patterns with different alignments and scales. It is shown that polarimetry in the back-reflected light is complementary to ellipsometry and four-polarisation camera imaging; experiments were carried out using a microscope.

7.
Adv Mater ; 36(31): e2401392, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38821489

RESUMO

Anatomizing mixed-phases, referring to analyzing the mixing profiles and quantifying the phases' proportions in a material, which is of great significance in the genuine applications. Here, by using second-harmonic generation (SHG) polarimetry and piezoresponse force microscopy (PFM) techniques, this work elucidates the contributions and distributions of two different symmetric phases mixed in an archetype monoaxial molecular ferroelectric, diisopropylammonium chloride (DIPACl). The two competing phases are preferred in thermodynamics or kinetic process respectively, and this work evidences the switching behavior between the two competing phases facilitated by an external electrical field as opposed to a heating process. This research contributes novel insights into phase engineering in the field of molecular ferroelectrics and is poised to serve as a potent analytical tool for subsequent applications.

8.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732780

RESUMO

This contribution focuses on the detection of tracer particles within non-homogeneous bulk media, aiming to enhance insights into particulate systems. Polarimetric radar measurements are employed, utilizing cross-polarizing channels in order to mitigate interference from bulk media reflections. To distinguish the tracer particle in the measurements, a resonant cross-polarizing structure is constructed, facilitating the isolation of frequency signatures from the surrounding bulk clutter. In addition to characterizing the bulk and tracer components, this study provides a detailed presentation and discussion of the measurement setup, along with the employed signal processing methods. The effectiveness of the proposed methods is demonstrated through comprehensive measurements, where a tracer particle is systematically positioned at various locations. The results affirm the feasibility and efficacy of the approach, highlighting its applicability for enhanced dynamic monitoring in particulate systems within industrial processes.

9.
ACS Nano ; 18(20): 12771-12780, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38708928

RESUMO

Three-dimensional (3D) plasmonic metamaterials, featuring well-arranged subwavelength nanostructures, facilitate effective coupling between electrical dipoles and incident electromagnetic waves. This coupling allows for unique optical responses including localized surface plasmon resonance (LSPR) and quasi-bound states in the continuum (q-BIC). While 3D plasmonic metamaterials with LSPR and q-BIC have been independently explored for sensors, achieving simultaneous optical responses in the near-infrared region remains challenging. Here, we present 3D plasmonic metamaterials that integrate LSPR and q-BIC within a single π-shaped plasmonic structure, fabricated using a 3D aerosol nanoprinting technique. This printing technique controls the local electrostatic field to precisely position charged metallic nanoaerosols, enabling parallel printing of π-shaped plasmonic structures under ambient conditions. The printed π-shaped plasmonic structures exhibit two distinct optical modes: x-polarization-sensitive LSPR and transverse magnetic mode-sensitive q-BIC within the near-infrared region. Exploiting these dual optical responses, we demonstrate simultaneous polarization detection and incident angle analysis by integrating the π-shaped plasmonic structures into commercial Fourier-transform infrared spectroscopy, termed "numerical aperture-detective polarimetry". This approach holds promise for evaluating alignment in optical and imaging systems with light distribution analysis. Furthermore, the 3D aerosol nanoprinting technique provides an avenue for fabricating 3D plasmonic metamaterials with intricate geometries and optical properties, expanding their potential applications in nano-optics.

10.
Biosensors (Basel) ; 14(4)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38667201

RESUMO

Polarization imaging and sensing techniques have shown great potential for biomedical and clinical applications. As a novel optical biosensing technology, Mueller matrix polarimetry can provide abundant microstructural information of tissue samples. However, polarimetric aberrations, which lead to inaccurate characterization of polarization properties, can be induced by uneven biomedical sample surfaces while measuring Mueller matrices with complex spatial illuminations. In this study, we analyze the detailed features of complex spatial illumination-induced aberrations by measuring the backscattering Mueller matrices of experimental phantom and tissue samples. We obtain the aberrations under different spatial illumination schemes in Mueller matrix imaging. Furthermore, we give the corresponding suggestions for selecting appropriate illumination schemes to extract specific polarization properties, and then provide strategies to alleviate polarimetric aberrations by adjusting the incident and detection angles in Mueller matrix imaging. The optimized scheme gives critical criteria for the spatial illumination scheme selection of non-collinear backscattering Mueller matrix measurements, which can be helpful for the further development of quantitative tissue polarimetric imaging and biosensing.


Assuntos
Técnicas Biossensoriais , Imagens de Fantasmas , Humanos
11.
J Biomed Opt ; 29(5): 052916, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38328279

RESUMO

Significance: Quantitative optical polarimetry has received considerable recent attention owing to its potential for being an efficient diagnosis and characterizing tool with potential applications in biomedical research and various other disciplines. In this regard, it is crucial to validate various Mueller matrix (MM) decomposition methods, which are utilized to extract and quantify the intrinsic individual polarization anisotropy properties of various complex optical media. Aim: To quantitatively compare the performance of both polar and differential MM decomposition methods for probing the structural and morphological changes in complex optical media through analyzing their intrinsic individual polarization parameters, which are extracted using the respective decomposition algorithms. We also intend to utilize the decomposition-derived anisotropy parameters to distinguish among the cervical tissues with different grades of cervical intraepithelial neoplasia (CIN) and to characterize the healing efficiency of an organic crystal. Approach: Polarization MM of the cervical tissues with different grades of CIN and the different stages of the self-healing crystal are recorded with a home-built MM imaging setup in the transmission detection geometry with a spatial resolution of ≈400 nm. The measured MMs are then processed with both the polar and differential MM decomposition methods to extract the individual polarization parameters of the respective samples. The derived polarization parameters are further analyzed to validate and compare the performance of both the MM decomposition methods for probing and characterizing the structural changes in the respective investigated optical media through their decomposition-derived intrinsic individual polarization properties. Results: Pronounced differences in the decomposed-derived polarization anisotropy parameters are observed for cervical tissue sections with different grades of CIN. While a significant increase in the depolarization parameter (Δ) is obtained with the increment of CIN stages for both the polar [Δ=0.32 for CIN grade one (CIN-I) and Δ=0.53 for CIN grade two (CIN-II))] and differential (Δ=0.35 for CIN-I and Δ=0.56 for CIN-II) decomposition methods, a trend reversal is seen for the linear diattenuation parameter (dL), indicating the structural distortion in the cervical morphology due to the CIN disease. More importantly, with the differential decomposition algorithm, the magnitude of the derived dL parameter decreases from 0.26 to 0.19 with the progression of CIN, which was not being probed by the polar decomposition method. Conclusion: Our results demonstrate that the differential decomposition of MM holds certain advantages over the polar decomposition method to characterize and probe the structural changes in the cervical tissues with different grades of CIN. Although the quantified individual polarization parameters obtained through both the MM decomposition methods can be used as useful metrics to characterize various optical media, in case of complex turbid media such as biological tissues, incorporation of the differential decomposition technique may yield more efficient information. Also, the study highlights the utilization of MM polarimetry with an appropriate decomposition technique as an efficient diagnostic and characterizing tool in the realm of biomedical clinical research, and various other disciplines.


Assuntos
Diagnóstico por Imagem , Refração Ocular , Anisotropia , Análise Espectral
12.
Front Neurol ; 15: 1330440, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38379704

RESUMO

Introduction: This study tested whether multiple traumatic brain injuries (TBIs) alter the structure of the Henle fiber layer (HFL) and degrade cell-specific function in the retinas of human participants. Methods: A cohort of case participants with multiple TBIs and a cohort of pair-matched control participants were prospectively recruited. Directional optical coherence tomography and scanning laser polarimetry measured HFL thickness and phase retardation, respectively. Full-field flash electroretinography (fERG) assessed retinal function under light-adapted (LA) 3.0, LA 30 Hz, dark-adapted (DA) 0.01, DA 3.0, and DA 10 conditions. Retinal imaging and fERG outcomes were averaged between both eyes, and paired t-tests or Wilcoxon signed-rank tests analyzed inter-cohort differences. Results: Global HFL thickness was significantly (p = 0.02) greater in cases (8.4 ± 0.9 pixels) than in controls (7.7 ± 1.1 pixels). There was no statistically significant difference (p = 0.91) between the cohorts for global HFL phase retardation. For fERG, LA 3.0 a-wave amplitude was significantly reduced (p = 0.02) in cases (23.5 ± 4.2 µV) compared to controls (29.0 ± 8.0 µV). There were no other statistically significant fERG outcomes between the cohorts. Discussion: In summary, the HFL thickens after multiple TBIs, but phase retardation remains unaltered in the macula. Multiple TBIs may also impair retinal function, indicated by a reduction in a-wave amplitude. These results support the potential of the retina as a site to detect TBI-associated pathology.

13.
Lasers Med Sci ; 39(1): 59, 2024 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-38336913

RESUMO

Tissue polarimetry has been gaining importance in extracting useful diagnostic information from the structural attributes of tissues, which vary in response to the tissue health status and hence find great potential in cancer diagnosis. However, the complexities associated with cancer make it challenging to isolate the characteristic changes as the tumor progresses using polarimetry. This study attempts to experimentally characterize the polarimetric behavior in colon cancer associated with various stages of development. Bulk and unstained sections of normal and tumor colon tissue were imaged in the reflection and transmission polarimetry configurations at low and high imaging resolutions using an in-house developed Mueller polarimeter. Through this study, we observed that the information about the major contributors of scattering in colon tissue, manifesting in depolarization and retardance, can be obtained from the bulk tissue and unstained sections. These parameters aid in characterizing the polarimetric changes as the colon tumor progresses. While the unstained colon section best indicated the depolarization contrast between normal and tumor, the contrast through the retardance parameter was more pronounced in the bulk colon tissue. The results suggest that the polarimetric "digitally stained" images obtained by Mueller polarimetry are comparable with the bulk tissue counterparts, making it useful for characterizing colon cancer tissues across different stages of development.


Assuntos
Neoplasias do Colo , Humanos , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Análise Espectral , Coloração e Rotulagem
14.
Sensors (Basel) ; 24(2)2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-38257648

RESUMO

To achieve optimal operation of the polarimetry-based FOCS, the light polarisation state at the input of the sensing fibre part must be close to a linear one. In the case of a FOCS deployed on a tokamak, the Joint European Torus (JET) in the present work, the long fibre optics link between the laser source and the sensing fibre modifies the polarisation in an unpredictable way, making it unclear which source polarisation state is to be set. A method for performing the necessary polarisation adjustment in a systematic way is proposed based on the FOCS analysis. The method requires performing data acquisition at two different input polarisations. Based on these measurements, the optimal laser source polarisation can be found. The method was experimentally verified using laboratory set-up and then successfully demonstrated with the FOCS installed at JET.

15.
J Phys Condens Matter ; 36(15)2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38171024

RESUMO

We establish the sign of the linear magnetoelectric (ME) coefficient,α, in chromia, Cr2O3. Cr2O3is the prototypical linear ME material, in which an electric (magnetic) field induces a linearly proportional magnetization (polarization), and a single magnetic domain can be selected by annealing in combined magnetic (H) and electric (E) fields. Opposite antiferromagnetic (AFM) domains have opposite ME responses, and which AFM domain corresponds to which sign of response has previously been unclear. We use density functional theory (DFT) to calculate the magnetic response of a single AFM domain of Cr2O3to an applied in-plane electric field at zero kelvin. We find that the domain with nearest neighbor magnetic moments oriented away from (towards) each other has a negative (positive) in-plane ME coefficient,α⊥, at zero kelvin. We show that this sign is consistent with all other DFT calculations in the literature that specified the domain orientation, independent of the choice of DFT code or functional, the method used to apply the field, and whether the direct (magnetic field) or inverse (electric field) ME response was calculated. Next, we reanalyze our previously published spherical neutron polarimetry data to determine the AFM domain produced by annealing in combinedEandHfields oriented along the crystallographic symmetry axis at room temperature. We find that the AFM domain with nearest-neighbor magnetic moments oriented away from (towards) each other is produced by annealing in (anti-)parallelEandHfields, corresponding to a positive (negative) axial ME coefficient,α∥, at room temperature. Sinceα⊥at zero kelvin andα∥at room temperature are known to be of opposite sign, our computational and experimental results are consistent.

16.
J Biophotonics ; 17(1): e202300252, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37743627

RESUMO

This study investigates the polarimetric properties of skin, skeletal muscle, connective tissue, and fat using Mueller matrix imaging. It aims to compare the polarimetric characteristics of these tissues and explore how they evolve with wavelength. Additionally, the temporal evolution of certain tissues during meat aging is studied, providing insights into the dynamic behavior of polarimetric properties over time. The research employs back-scattering configuration and the differential decomposition analysis method of Mueller matrix images. Both in-vivo and ex-vivo experiments were conducted using a consistent instrument setup to ensure reliable analysis. The results reveal wavelength-dependent variations in tissue properties, including an increase in depolarization with wavelength. Significant differences in the polarimetric characteristics of meat tissues, particularly for skeletal muscle, are observed. Over a 24-h period, intensity, diattenuation, and retardation experience alterations, being the decreased retardation in skeletal muscle and the increased retardation in fat the most notable ones.


Assuntos
Diagnóstico por Imagem , Músculo Esquelético , Análise Espectral , Músculo Esquelético/diagnóstico por imagem , Pele/diagnóstico por imagem , Tecido Conjuntivo/diagnóstico por imagem
17.
J Biomed Opt ; 29(5): 052914, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38077501

RESUMO

Significance: Knowledge of fiber microstructure and orientation in the brain is critical for many applications. Polarized light imaging (PLI) has been shown to have potential for better understanding neural fiber microstructure and directionality due to the anisotropy in myelin sheaths surrounding nerve fibers of the brain. Continuing to advance backscattering based PLI systems could provide a valuable avenue for in vivo neural imaging. Aim: To assess the potential of backscattering PLI systems, the ability to resolve crossing fibers, and the sensitivity to fiber inclination and curvature are considered across different imaging wavelengths. Approach: Investigation of these areas of relative uncertainty is undergone through imaging potential phantoms alongside analogous regions of interest in fixed ferret brain samples with a five-wavelength backscattering Mueller matrix polarimeter. Results: Promising phantoms are discovered for which the retardance, diattenuation and depolarization mappings are derived from the Mueller matrix and studied to assess the sensitivity of this polarimeter configuration to fiber orientations and tissue structures. Conclusions: Rich avenues for future study include further classifying this polarimeter's sensitivity to fiber inclination and fiber direction to accurately produce microstructural maps of neural tissue.


Assuntos
Furões , Bainha de Mielina , Animais , Imagens de Fantasmas , Encéfalo/diagnóstico por imagem , Imagem Óptica/métodos
18.
J Biomed Opt ; 29(5): 052915, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38077502

RESUMO

Significance: Current treatment for stage III colorectal cancer (CRC) patients involves surgery that may not be sufficient in many cases, requiring additional adjuvant systemic therapy. Identification of this latter cohort that is likely to recur following surgery is key to better personalized therapy selection, but there is a lack of proper quantitative assessment tools for potential clinical adoption. Aim: The purpose of this study is to employ Mueller matrix (MM) polarized light microscopy in combination with supervised machine learning (ML) to quantitatively analyze the prognostic value of peri-tumoral collagen in CRC in relation to 5-year local recurrence (LR). Approach: A simple MM microscope setup was used to image surgical resection samples acquired from stage III CRC patients. Various potential biomarkers of LR were derived from MM elements via decomposition and transformation operations. These were used as features by different supervised ML models to distinguish samples from patients that locally recurred 5 years later from those that did not. Results: Using the top five most prognostic polarimetric biomarkers ranked by their relevant feature importances, the best-performing XGBoost model achieved a patient-level accuracy of 86%. When the patient pool was further stratified, 96% accuracy was achieved within a tumor-stage-III sub-cohort. Conclusions: ML-aided polarimetric analysis of collagenous stroma may provide prognostic value toward improving the clinical management of CRC patients.


Assuntos
Neoplasias Colorretais , Aprendizado de Máquina , Humanos , Prognóstico , Biomarcadores , Terapia Combinada , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia
19.
J Biomed Opt ; 29(5): 052913, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38089555

RESUMO

Significance: Phase retardation of circularly polarized light (CPL), backscattered by biological tissue, is used extensively for quantitative evaluation of cervical intraepithelial neoplasia, presence of senile Alzheimer's plaques, and characterization of biotissues with optical anisotropy. The Stokes polarimetry and Mueller matrix approaches demonstrate high potential in definitive non-invasive cancer diagnosis and tissue characterization. The ultimate understanding of CPL interaction with tissues is essential for advancing medical diagnostics, optical imaging, therapeutic applications, and the development of optical instruments and devices. Aim: We investigate propagation of CPL within turbid tissue-like scattering medium utilizing a combination of Jones and Stokes-Mueller formalisms in a Monte Carlo (MC) modeling approach. We explore the fundamentals of CPL memory effect and depolarization formation. Approach: The generalized MC computational approach developed for polarization tracking within turbid tissue-like scattering medium is based on the iterative solution of the Bethe-Salpeter equation. The approach handles helicity response of CPL scattered in turbid medium and provides explicit expressions for assessment of its polarization state. Results: Evolution of CPL backscattered by tissue-like medium at different conditions of observation in terms of source-detector configuration is assessed quantitatively. The depolarization of light is presented in terms of the coherence matrix and Stokes-Mueller formalism. The obtained results reveal the origins of the helicity flip of CPL depending on the source-detector configuration and the properties of the medium and are in a good agreement with the experiment. Conclusions: By integrating Jones and Stokes-Mueller formalisms, the combined MC approach allows for a more complete representation of polarization effects in complex optical systems. The developed model is suitable to imitate propagation of the light beams of different shape and profile, including Gaussian, Bessel, Hermite-Gaussian, and Laguerre-Gaussian beams, within tissue-like medium. Diverse configuration of the experimental conditions, coherent properties of light, and peculiarities of polarization can be also taken into account.


Assuntos
Dispositivos Ópticos , Espalhamento de Radiação , Análise Espectral , Anisotropia , Método de Monte Carlo
20.
Sensors (Basel) ; 23(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38067679

RESUMO

We report on a study of the temperature dependence of the response of a BSO crystal based polarimetric current sensor with spectral interrogation. Two possible interrogation schemes are discussed. The spectral dependence of the optical rotation along the crystal caused by temperature and current changes is investigated, and approximate dependences for the sensitivities to current SI and temperature ST are derived. A mixed term in the response with spectral interrogation is revealed, the elimination of which is achieved by tracking wavelength shifts Δλ1 and Δλ2 of two distinct extrema in the polarimetric response. A temperature independent second degree equation for the current changes ΔI as a function of the measured spectral shifts is derived and tested.