Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(14)2023 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-37514786

RESUMO

This paper describes the use of an optical instrument, the Fabry-Perot interferometer, adapted to measure very low pressures. The interferometer consists of two high-reflectance flat mirrors placed one in front of another. In addition, a metallic chamber contains air or a gas. In one of the faces of the chamber, a flexible thin silicone membrane is attached and, over it, one of the mirrors is glued. The other mirror rests in a fixed mechanical mounting. Light crosses both mirrors and, when it leaves them, forms an interference pattern consisting of concentric circular fringes. When the pressure is increased/decreased within the chamber, a displacement of the fringes is observed due to the movement of the glued mirror. By measuring the fringe displacement and knowing the pressure, a calibration plot can be made. Minimum pressure measurements of about tens of Pascals were achieved.

2.
Materials (Basel) ; 15(20)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36295406

RESUMO

Facial prosthetics are currently constructed of materials that are far from optimal; superior materials with a "skin-like" feel are required. In this study, the property changes brought about by the consecutive additions of hydrophobic- and uncoated nano-SiO2 to polydimethylsiloxane (PDMS) are assessed, and the alterations are compared with those observed for conventional submicron SiO2-filled materials. In sequence, 0%, 0.5%, 5%, 10%, and 15% by weight of each filler type were successively added to vinyl-terminated PDMS. Tensile, tear, Durometer hardness, translucency, and viscoelastic properties were assessed, and hardness and translucency were further measured after 3000 h of outdoor weathering. The results showed that 15% coated nano- SiO2-filled PDMS materials given the highest tensile strength, elastic modulus, storage modulus, loss modulus, tear strength, and durometer hardness (p < 0.05), whereas 15% submicron coated SiO2-filled materials displayed the highest failure strain and translucency parameter (p < 0.05). Only 10%- and 15%-filled submicron SiO2 PDMS materials were altered by outdoor weathering; nevertheless, the increases were assessed to be too small to be clinically perceptible. As increased filler levels provided protection against solar radiation, heat, and moisture, only unfilled and 0.5%-filled PDMS formulations discolored from weathering. 15%-filled superhydrophobic-coated nano- SiO2-filled PDMS was found to produce the strongest, most tear-resistant, and least translucent materials, but it also produced materials with limited stretchability and high hardness, which were regarded to be downsides for creating a "skin-like" feel.

3.
Polymers (Basel) ; 14(10)2022 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-35631994

RESUMO

Tailored ZnO surface functionalization was performed inside a polydimethyl-siloxane (PDMS) microchannel of a micro-optofluidic device (mofd) to modulate its surface hydrophobicity to develop a method for fine tuning the fluid dynamics inside a microchannel. The wetting behavior of the surface is of particular importance if two different phases are used for system operations. Therefore, the fluid dynamic behavior of two immiscible fluids, (i) air-water and (ii) air-glycerol/water in PDMS mofds and ZnO-PDMS mofds was investigated by using different experimental conditions. The results showed that air-glycerol/water fluid was always faster than air-water flow, despite the microchannel treatment: however, in the presence of ZnO microstructures, the velocity of the air-glycerol/water fluid decreased compared with that observed for the air-water fluid. This behavior was associated with the strong ability of glycerol to create an H-bond network with the exposed surface of the zinc oxide microparticles. The results presented in this paper allow an understanding of the role of ZnO functionalization, which allows control of the microfluidic two-phase flow using different liquids that undergo different chemical interactions with the surface chemical terminations of the microchannel. This chemical approach is proposed as a control strategy that is easily adaptable for any embedded micro-device.

4.
Materials (Basel) ; 14(6)2021 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-33809490

RESUMO

This study aims to establish whether the use of biomaterials, particularly polydimethylsiloxane (PDMS), for surgical reconstruction of the esophagus with templates, Montgomery salivary tube, after radical oncology surgery for malignant neoplasia is an optimal choice for patients' safety and for optimal function preservation and organ rehabilitation. Structural analysis by Raman spectrometry and biomechanical properties with dynamic mechanical analysis are performed for fatigue strength and toughness, essential factors in durability of a prosthesis in the reconstruction practice of the esophagus. Nanocomposites with silicone elastomers and nanoparticles used in implantable devices and in reconstruction surgery present risks of infection and fatigue strength when required to perform a mechanical effort for long periods of time. This report takes into account the effect of silver (Ag) nanoparticles on the fatigue strength using polydimethylsiloxane (PDMS) matrix, representative for silicon elastomers used in implantable devices. PDMS with 5% (wt) Ag nanoparticles of 100-150 nm during mechanical fatigue testing at shear strength loses elasticity properties after 400 loading-unloading cycles and up to 15% shear strain. The fatigue strength, toughness, maximum shear strength, as well as clinical properties are key issues in designing Montgomery salivary tube and derivates with appropriate biomechanical behavior for each patient. Prosthesis design needs to indulge both clinical outcomes as well as design methods and research in the field of biomaterials.

5.
Microsc Res Tech ; 82(2): 149-152, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30556275

RESUMO

To evaluate the fill of internal resorption cavities obturated with thermoplasticized gutta-percha and GuttaFlow2 using CT scan. Twenty human maxillary anterior teeth were selected and root canals were prepared using ProTaper system to size F3. Irrigation was performed with 5 ml of 2.5% sodium hypochlorite (NaOCl) and 5 ml of 17% ethylenediaminetetraacetic acid (EDTA). Each root was then sectioned horizontally into two halves and semicircular cavities were prepared around the periphery of the root canal opening of each root half, using a round bur. Both the root halves were then fixed using cyanoacrylate glue. All the specimens were subjected to preoperative CT scan analysis to determine the volume of internal cavities. The samples were then randomly divided into two groups. In Group 1, the specimens were obturated with thermoplasticized gutta-percha (E&Q system) and specimens in Group 2 were obturated using GuttaFlow2. All specimens were then subjected to postoperative CT scan analysis. The volume of voids in internal resorptive cavities were calculated, which was then used to estimate the amount of gutta-percha filled. There was no significant difference in volume of internal resorptive cavities between thermoplasticized gutta-percha and GuttaFlow2 groups before obturation (p = 0.466). However, after obturation there was a significant difference between both the groups, in which GuttaFlow2 demonstrated better fill (p = .014). Thermoplasticized gutta-percha filled 81% of internal resorptive cavity while GuttaFlow2 filled 91%, respectively. GuttaFlow2 showed better fill than thermoplasticized gutta-percha in the filling of internal resorptive cavities.


Assuntos
Restauração Dentária Permanente/métodos , Dimetilpolisiloxanos/administração & dosagem , Guta-Percha , Materiais Restauradores do Canal Radicular , Obturação do Canal Radicular/métodos , Humanos , Tomografia Computadorizada Espiral , Resultado do Tratamento
6.
J Biomed Mater Res B Appl Biomater ; 107(5): 1634-1644, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30332525

RESUMO

Composition and architecture of scaffolds are the most important factors determining the performance of skin substitutes. In this work, morphology induced unique physical and biological characteristics of compatibilized TPU-PDMS blend scaffolds at 90:10, 80:20, and 70:30 blend ratios of TPU and PDMS was studied. The fiber morphology, porosity, surface wettability, and mechanical properties of electrospun scaffolds were distinctly influenced by the presence of PDMS. Interestingly, the scaffold architecture varied from electrospun fibers to porous fibers and finally occurrence of unique porous beads noticed at 30% PDMS in the microstructure which was confirmed using FESEM. Micro-CT analysis revealed that the porosity of electrospun scaffolds was enhanced from 61% to 79% with 30 parts of PDMS addition. Moreover, MTT assay and cell proliferation were studied using human skin fibroblast cells and found to be significantly enhanced with the PDMS percentage. TPU-PDMS blends offer better overall performance at 70:30 blend ratio of TPU and PDMS (T70P30). Only 4% of hemolysis was observed for T70P30 blends, which establishes the hemocompatibility of the material. In comparison, the results reveal the potential of the cytocompatible T70P30 scaffold for the fabrication of skin substitutes for tissue engineering applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1634-1644, 2019.


Assuntos
Resinas Compostas/química , Dimetilpolisiloxanos/química , Nanoestruturas/química , Poliuretanos/química , Pele Artificial , Alicerces Teciduais/química , Linhagem Celular , Proliferação de Células/efeitos dos fármacos , Fibroblastos/citologia , Humanos , Porosidade , Pele/metabolismo , Propriedades de Superfície , Engenharia Tecidual
7.
J Biomed Mater Res B Appl Biomater ; 105(5): 1075-1082, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-26990909

RESUMO

Polydimethyl siloxane (PDMS) is an excellent implant material for biomedical applications, but often fails as it is prone to microbial colonization which forms biofilms. In the present study CuO, CTAB capped CuO, and ZnO nanoparticles were tested as nanofillers to enhance the antibiofilm property of PDMS against Staphylococcus aureus and Escherichia coli. In general S. aurues (Gram positive and more hydrophobic) favor PDMS surface than glass while E. coli (Gram negative and more hydrophilic) behaves in a reverse way. Incorporation of nanofillers renders the PDMS surface antibacterial and reduces the attachment of both bacteria. These surfaces are also not cytotoxic nor show any cell damage. Contact angle of the material and the cell surface hydrophobicity influenced the extent of bacterial attachment. Cell viability in biofilms was dependent on the antimicrobial property of the nanoparticles incorporated in the PDMS matrix. Simple regression relationships were able to predict the bacterial attachment and number of dead cells on these nanocomposites. Among the nanocomposites tested, PDMS incorporated with CTAB (cetyl trimethylammonium bromide)-capped CuO appears to be the best antibacterial material with good cyto-compatibility. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1075-1082, 2017.


Assuntos
Biofilmes/crescimento & desenvolvimento , Compostos de Cetrimônio , Cobre , Dimetilpolisiloxanos , Escherichia coli/fisiologia , Nanocompostos/química , Staphylococcus aureus/fisiologia , Animais , Aderência Bacteriana/efeitos dos fármacos , Linhagem Celular , Cetrimônio , Compostos de Cetrimônio/química , Compostos de Cetrimônio/farmacologia , Cobre/química , Cobre/farmacologia , Dimetilpolisiloxanos/química , Dimetilpolisiloxanos/farmacologia , Ratos
8.
Talanta ; 161: 450-458, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27769431

RESUMO

The polymer, polystyrene polydimethyl siloxane was loaded into the micropipette tip of the syringe system as an adsorbent to developed miniaturized solid phase microextraction. Standard solutions of arsenate and arsenite were passed through the adsorbent loaded in micropipette tip to check the adsorption behaviors. It was observed that arsenate adsorbed on the polystyrene polydimethyl siloxane in the pH rang of 6-8, while arsenite was directly passed through the micropipette tip of syringe system. The adsorbed arsenate in micropipette tip of syringe system were eluted by 1.0M hydrochloric acid. The total inorganic arsenic contents were obtained by the addition of oxidizing agent potassium permanganate into the studied samples before passing to the micropipette tip of syringe system. Arsenite concentration in water samples were measured by subtracting arsenate from total inorganic arsenic concentration. Different characteristics which effect the determination of arsenate specie like amount of adsorbent, adsorption capacity, pH, pulled and pushed cycles for adsorption and desorption, volume of sample, eluent type and it volume were also studied in detail. Enrichment factor and detection limit of arsenate by desired method were 218 and 6.9ngL-1 respectively. The relative standard deviation was 4.1% (n=10, C=0.12µgL-1). Accuracy of the desired technique was confirmed by analysis of the CRMs (Lake Ontario Water TM-28.3 and Riverine Water NRCC-SLRS-4). Desired technique was significantly useful for determination of the total arsenic, arsenate, and arsenite contents in different natural water samples.

9.
J Mech Behav Biomed Mater ; 46: 305-17, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25840121

RESUMO

Research on human skin interactions with healthcare and lifestyle products is a topic continuously attracting scientific studies over the past years. It is possible to evaluate skin mechanical properties based on human or animal experimentation, yet in addition to possible ethical issues, these samples are hard to obtain, expensive and give rise to highly variable results. Therefore, the design of a skin equivalent is essential. This paper describes the design and characterization of a new Epidermal Skin Equivalent (ESE). The material resembles the properties of epidermis and is a first approach to mimic the mechanical properties of the human skin structure, variable with the length scale. The ESE is based on a mixture of Polydimethyl Siloxane (PDMS) and Polyvinyl Alcohol (PVA) hydrogel cross-linked with Glutaraldehyde (GA). It was chemically characterized by XPS and FTIR measurements and its cross section was observed by macroscopy and cryoSEM. Confocal Microscope analysis on the surface of the ESE showed an arithmetic roughness (Ra) between 14-16 µm and contact angle (CA) values between 50-60°, both of which are close to the values of in vivo human skins reported in the literature. The Equilibrium Water Content (ECW) was around 33.8% and Thermo Gravimetric Analysis (TGA) confirmed the composition of the ESE samples. Moreover, the mechanical performance was determined by indentation tests and Dynamo Thermo Mechanical Analysis (DTMA) shear measurements. The indentation results were in good agreement with that of the target epidermis reported in the literature with an elastic modulus between 0.1-1.5 MPa and it showed dependency on the water content. According to the DTMA measurements, the ESE exhibits a viscoelastic behavior, with a shear modulus between 1-2.5MPa variable with temperature, frequency and the hydration of the samples.


Assuntos
Absorção Fisico-Química , Materiais Biomiméticos/química , Dimetilpolisiloxanos/química , Epiderme , Interações Hidrofóbicas e Hidrofílicas , Álcool de Polivinil/química , Água/química , Módulo de Elasticidade , Humanos , Propriedades de Superfície , Viscosidade
10.
J Biomed Mater Res A ; 102(4): 947-57, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23650270

RESUMO

This article reports the surface modification of electrospun polycarbonate urethane membrane with polydimethyl siloxane (PDMS) using plasma-induced grafting technique for biomedical applications. The nonwoven membranes were characterized for their structure, performance, and compatibility with cells. The surface modification was confirmed by means of attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and energy dispersive X-ray analysis (EDXA). ATR-FTIR and EDXA analyses displayed characteristic absorption peaks of PDMS for the membrane. The structure and morphology of the developed membranes were studied using scanning electron microscope and microcomputed tomography (µCT). Scanning electron microscopy and µCT revealed the fibrous morphology and percentage porosity of the membranes before and after plasma modification. Static mechanical tests showed that the tensile strength was greater than 8 MPa. Physical characterization of the membranes after immersion in hydrolytic and oxidative media supports their biostability. Cytotoxicity of the membrane was evaluated using L929 fibroblast cells, and the results indicated that the membrane is cytocompatible. Accordingly, these results highlight the potential of this fibrous membrane for biomedical applications.


Assuntos
Dimetilpolisiloxanos/química , Teste de Materiais/métodos , Fenômenos Mecânicos , Membranas Artificiais , Gases em Plasma/química , Cimento de Policarboxilato/química , Uretana/química , Animais , Morte Celular , Linhagem Celular , Sobrevivência Celular , Líquido Cefalorraquidiano/química , Camundongos , Microscopia Eletrônica de Varredura , Porosidade , Espectrometria por Raios X , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Molhabilidade
11.
J Biomed Mater Res A ; 102(5): 1361-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23733484

RESUMO

We have adapted our existing compression-induced fracture technology to cell culture studies by generating linear patterns on a complex cell culture well structure rather than on simple solid constructs. We present a simple method to create one-dimensional (1D), submicron, and linear patterns of extracellular matrix on a multilayer silicone material. We identified critical design parameters necessary to optimize compression-induced fracture patterning on the wells, and applied stresses using compression Hoffman clamps. Finite-element analyses show that the incorporation of the well improves stress homogeneity (stress variation = 25%), and, thus, crack uniformity over the patterned region. Notably, a shallow well with a thick base (vs. deeper wells with thinner bases) reduces out-of-plane deflections by greater than a sixth in the cell culture region, improving clarity for optical imaging. The comparison of cellular and nuclear shape indices of a neuroblast line cultured on patterned 1D lines and unpatterned 2D surfaces reveals significant differences in cellular morphology, which could impact many cellular functions. Because 1D cell cultures recapitulate many important phenotypical traits of 3D cell cultures, our culture system offers a simple means to further study the relationship between 1D and 3D cell culture environments, without demanding expensive engineering techniques and expertise.


Assuntos
Células/efeitos dos fármacos , Força Compressiva , Silicones/farmacologia , Estresse Mecânico , Animais , Forma do Núcleo Celular/efeitos dos fármacos , Forma Celular/efeitos dos fármacos , Células Cultivadas , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA