Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.447
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38915785

RESUMO

Endoscopic submucosal dissection (ESD) is a transformative advancement in the endoscopic management of superficial gastrointestinal lesions. Initially conceived for the treatment of early gastric cancer, ESD has demonstrated proficiency in achieving en-bloc resection of superficial gastrointestinal lesions. ESD has experienced widespread acceptance in Japan and East Asia; however, its adoption in the USA remains delayed. This initial hesitancy could be attributed to procedural complexity and training demands; nonetheless, recently, ESD has been gaining popularity in the USA. This is due to the advancements in endoscopic technology, tailored training programs, and cumulative evidence regarding the efficacy and safety of ESDs. This review aimed to deliberate the historical progress, current implementation, and prospective trajectory of ESDs in the USA. With ongoing clinical research, technological integration, and educational efforts, ESD is likely to become the gold standard for managing large gastrointesitinal lesions. This progress marks an imperative step toward less invasive, more precise, and patient-centric approaches regarding advanced therapeutic endoscopy in the USA.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39311943

RESUMO

BACKGROUND: Robotic-assisted surgical technique has been clinically available for decades, yet real-world adverse events (AEs) and complications associated with primary knee arthroplasty remain unclear. METHODS: In March 2023, we searched the FDA website and extracted AEs related to robotic assisted knee arthroplasty (RAKA) from the MAUDE database over the past 10 years. The "Brand Name" function queried major robotic platforms, including active and semi-active systems. The overall incidence of AEs was estimated based on annual surgical volume from the current American Joint Replacement Registry (AJRR). Two authors independently collected data on event date, event type, device problem, and patient problem. RESULTS: Of 839 eligible reports, device malfunction comprised mechanical failure (343/839, 40.88%) and software failure (261/839, 31.11%). For surgical complications, inappropriate bone resection (115/839, 13.71%) was most frequent, followed by bone/soft tissue damage (83/839, 9.89%). Notably, over-resection exceeding 2 mm (88/839, 10.49%), joint infection (25/839, 2.98%), and aseptic loosening (1/839, 0.12%) were major complications. Only two track pins related AEs were found. Moreover, the distribution of these AEs differed substantially between robot manufacturers. According to the AEs volume and AJRR data, the overall incidences of AEs related to RAKAs were calculated with 0.83% (839/100,892) between November 2010 and March 2023. CONCLUSION: Our analysis shows that while reported AEs might be increasing for RAKAs, the overall rate remains relatively low. Reassuringly, device malfunction was the most commonly AEs observed, with a minor impact on postoperative outcomes. Furthermore, our data provide a benchmark for patients, surgeons, and manufacturers to evaluate RAKA performance, though continued improvement in reducing serious AEs incidence is warranted.

3.
J Robot Surg ; 18(1): 345, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39311983

RESUMO

Gynecologic surgery with minimally invasive method using robotic or laparoscopic techniques has gained popularity for reducing perioperative discomfort and length of hospital stay. However, the debate over postoperative pain superiority between traditional laparoscopy and robotic surgery persist. This study compared the postoperative pain of patients within 24 h of robotic (RM) and laparoscopic myomectomy (LM). This retrospective cohort study included 24 and 53 patients who underwent RM and LM, respectively, between January 2019 and July 2023. The primary outcomes were the postoperative pain levels of patients within 24 h and the use and dosage of postoperative analgesia. Additional perioperative analgesia, including long-acting non-steroidal anti-inflammatory drugs (Dynastat) and abdominal nerve block, was also recorded. The secondary outcomes were blood loss and hospitalization duration. The patient characteristics were similar between the groups. Factors that could potentially increase pain, such as the number of ports (p < 0.0001), additional procedures (p = 0.0195), operative time (p < 0.0001), number of myomas (p = 0.0057), and the largest myoma size (p = 0.0086), were significantly higher in the RM group than in the LM group. However, there were no significantly different in the postoperative visual analog scale pain scores, use and dosage of ketorolac and opioid, and use of Dynastat and nerve block between the groups. Hospitalization duration and intraoperative blood loss were similar between the groups. RM and LM offer comparable postoperative pain outcomes, emphasizing the importance of patient-specific factors in decision-making regarding myomectomy techniques.


Assuntos
Laparoscopia , Dor Pós-Operatória , Procedimentos Cirúrgicos Robóticos , Miomectomia Uterina , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/etiologia , Miomectomia Uterina/métodos , Miomectomia Uterina/efeitos adversos , Feminino , Laparoscopia/métodos , Laparoscopia/efeitos adversos , Adulto , Pessoa de Meia-Idade , Neoplasias Uterinas/cirurgia , Estudos de Coortes , Duração da Cirurgia , Anti-Inflamatórios não Esteroides/uso terapêutico , Anti-Inflamatórios não Esteroides/administração & dosagem , Medição da Dor , Tempo de Internação/estatística & dados numéricos , Analgésicos Opioides/uso terapêutico , Analgésicos Opioides/administração & dosagem , Leiomioma/cirurgia , Perda Sanguínea Cirúrgica/estatística & dados numéricos
4.
J Robot Surg ; 18(1): 344, 2024 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-39312042

RESUMO

To compare perioperative outcomes of robot-assisted radical cystectomy (RARC) using a single-port (SP) or multi-port (MP) robotic platform. We conducted a comprehensive search of the PubMed, Web of Science, Scopus, and Google Scholar databases until June 2024. For a combined analysis of the data using random effects, Review Manager 5.4 was employed. To compare continuous and categorical variables, the weighted mean difference (WMD) and odds ratio (OR) were employed, respectively. Three original studies were included, comprising a total of 170 patients (SP-RARC: 73 versus MP-RARC: 93).Recovery of bowel function was faster in SP-RARC (WMD -1.02 days, 95% CI - 1.33 to - 0.17; p < 0.001), and lymph-node yield was lower than in MP-RARC patients (WMD - 6.32, 95% CI - 8.90 to - 3.75; p < 0.00001).There were no significant differences between the SP-RARC and MP-RARC groups in terms of other perioperative outcomes such as surgery duration, length of hospital stay, estimated blood loss, major complication rate, positive surgical margin rate, readmission rate, and recurrence rate. The SP robot offers a safe alternative surgical approach to RARC, providing similar postoperative outcomes compared to the MP robot. The SP system remains an attractive option that will require longer follow-up and cohort validation in the future.


Assuntos
Cistectomia , Tempo de Internação , Procedimentos Cirúrgicos Robóticos , Neoplasias da Bexiga Urinária , Cistectomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Humanos , Resultado do Tratamento , Neoplasias da Bexiga Urinária/cirurgia , Tempo de Internação/estatística & dados numéricos , Duração da Cirurgia , Recuperação de Função Fisiológica , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Perda Sanguínea Cirúrgica/estatística & dados numéricos
5.
Int J Colorectal Dis ; 39(1): 144, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39289218

RESUMO

PURPOSE: A novel robotic platform-Hugo™ RAS (robotic-assisted surgery) system-has been introduced with several innovations that may prove advantageous for surgeons, such as an open console and four interchangeable modular arms. Our study aims to evaluate this platform's safety, efficacy, and potential impact on the surgical treatment of colorectal pathology. METHODS: Patients underwent robotic-assisted colorectal procedures with the Hugo™ RAS system at the General University Hospital of Elche from October 2023 to July 2024. Patient characteristics, intraoperative and postoperative variables, and robotic technical issues were recorded. RESULTS: Forty consecutive patients were included (14 right, 13 left, and 8 rectum neoplasms; 4 left diverticulitis; and 1 ileocecal Crohn's disease). The patients' characteristics were as follows: median age, 69.5 years; 24 males and 16 females; 45% ASA III-IV; and Charlson Comorbidity Index > 5:42.5%. We recorded four medical (2 anemia, 1 phlebitis, and 1 admission to the intensive care unit) and three surgical (1 hematoma of the incision, 1 intestinal occlusion, and 1 dehiscence of the anastomosis) postoperative complications. We had no conversions neither open nor laparoscopic surgery. The average hospital stay was 3 days, with no mortality or readmission. CONCLUSIONS: The Hugo™ RAS system is safe and feasible for colorectal procedures. The modularity of the arms provides the versatility of configurations adjusted depending on the patient's body features and the surgeon's preferences and greater adaptability to operating rooms. The open console is highly comfortable and ergonomic for the surgeon, allowing communication with the operating room environment. TRIAL REGISTRATION: NCT06512480.


Assuntos
Procedimentos Cirúrgicos Robóticos , Centros de Atenção Terciária , Humanos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Feminino , Masculino , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Cirurgia Colorretal , Complicações Pós-Operatórias/etiologia , Idoso de 80 Anos ou mais , Tempo de Internação , Adulto
6.
CRSLS ; 11(2)2024.
Artigo em Inglês | MEDLINE | ID: mdl-39296515

RESUMO

Introduction: While vaginal agenesis most often occurs with an absent or rudimentary, nonfunctioning uterus, it may also occur with a fully developed uterine body. In these scenarios, anastomosis of the functional uterus to a neovagina allows for both egress of menstrual blood as well as potential preservation of fertility: case reports exist of spontaneous conception following creation of a neovagina. However, prior attempts at anastomosis have all included delayed surgery with anastomosis to the uterus several months following the creation of the neovagina. Case Description: The patient was a 17-year-old female who presented with amenorrhea several years after thelarche. After noting a blind ending vagina and a 46XX karyotype, ultrasound and MRI revealed an apparently normal uterus with questionable presence of a cervix, and polycystic appearing ovaries, which may have accounted for the patients minimal hematometra. A multidisciplinary team including gynecology, urology, plastic surgery, and colorectal surgery was organized for creation of a neovagina and attempted anastomosis to the normal appearing uterus. In a single staged robotic procedure, a peritoneal neovagina created in a modified Davydov technique was successfully connected to the uterus. A foley catheter was placed in the uterine cavity to allow for canalization. Diagnostic hysteroscopy six weeks after surgery confirmed a canal into the uterus, and the patient reported ongoing cyclical bleeding with the use of oral contraceptives several months after surgery. Conclusions: In vaginal agenesis with a functional upper reproductive tract, peritoneal neovaginas may be successfully anastomosed to the uterus in a single stage robotic approach.


Assuntos
Anastomose Cirúrgica , Útero , Vagina , Humanos , Feminino , Vagina/cirurgia , Vagina/anormalidades , Adolescente , Útero/anormalidades , Útero/cirurgia , Útero/diagnóstico por imagem , Anastomose Cirúrgica/métodos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Anormalidades Congênitas
7.
Surg Oncol ; 57: 102138, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39299027

RESUMO

BACKGROUND: Prostate cancer is the most common cancer in men with more than 52,000 cases diagnosed every year on average. With the introduction of robotic surgery, robotic assisted radical prostatectomy (RARP) has become a popular treatment option in recent years. Achieving oncological control, urinary continence and satisfactory erectile sexual function after RP is the main goal also known as "trifecta". All these outcomes are highly influenced by surgical experience and caseload. The main objective of this study is to analyze oncological and functional outcomes in RARP after 15 years of experience. METHODS: From 2008 until December 2023, 1790 RARP for localized prostate cancer were performed. A retrospective analysis was conducted based on prospectively collected data correlated with electronic medical records. RESULTS: Subgroup analyses were conducted in order to evaluate oncological and functional outcomes (n: 1400). Red blood cell transfusion and conversion to open surgery rate was 1.9 % and 0.1 %, respectively. Mean surgical time was 194 min. Mean follow-up time was 69.5 months, 23.8 % patients experienced biochemical recurrence and 1 % died, primarily due to disease progression. Estimated 10-year recurrence-free survival was 68.7 % (95 % CI 67.2-72.2) while estimated 10-year overall survival was 97.9 % (95 % CI 96.3-99.4). Overall urinary continence rate at 2 years was 86.9 % while satisfactory erectile function rate at 18 months was 56.8 %. CONCLUSIONS: Robotic-assisted radical prostatectomy has become a standard surgical technique in our urological practice for the management of clinically localized and locally advanced prostate tumors in selected cases. After 15 years since the inception of our robotic surgery program, we can conclude that our results are comparable to those published in the international literature, enabling patients to maintain satisfactory sexual function with a high continence rate within the first year of surgery.

8.
Artigo em Inglês | MEDLINE | ID: mdl-39299513

RESUMO

STUDY OBJECTIVE: Ob/Gyn resident experience with robotic gynecologic surgery has been evaluated at time of graduation, but no specific surgical procedures were identified to differentiate the experiences of residents at each level. This study proposes to determine which factors are correlated with more hands-on robotic surgery experience and resident satisfaction. DESIGN: An IRB-approved, 15-question survey was distributed electronically. 98 responses were received for a rate of 44%. Linear regression and ANOVA statistical analysis were performed. SETTING: Current residents at eight Ob/gyn residency programs in the US were surveyed. PATIENTS: N/A INTERVENTIONS: Survey administration MEASUREMENT AND MAIN RESULTS: The majority of respondents were satisfied (48%) or had neutral feelings (20%) with regard to their robotic surgery experience. All respondents reported experience with uterine manipulation or bedside assisting by PGY2. Earliest experience performing hysterectomy was most common in PGY2 or PGY3. Seventy-six percent of PGY3 or PGY4 residents report operating on the console for some or all major robotic surgeries, with 69% having participated in greater than 20 robotic surgery cases during residency. Only exposure to MIGS faculty is significantly associated with high robotic surgery experience (p=.022). Overall satisfaction with robotic surgery experience increased significantly with higher level of participation (p<.0001), particularly operating at the console during some or most of the surgery; longitudinal experiences with hysterectomy, myomectomy, and salpingectomy/oophorectomy (p<.05); but not with solely bedside assisting or vaginal cuff closure. Factors limiting robotic console experience included case time constraints, lack of first assists, case complexity, and attending comfort. CONCLUSIONS: Ob/Gyn resident satisfaction with training is significantly related to level and duration of robotic surgery participation. MIGS faculty contribute to more resident experience, and limiting factors include time constraints, case complexity and lack of first assists. These results can provide a framework for structuring resident training in robotic surgery.

9.
Neurocrit Care ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300038

RESUMO

BACKGROUND: Transcranial color Doppler (TCD) is currently the only noninvasive bedside tool capable of providing real-time information on cerebral hemodynamics. However, being operator dependent, TCD monitoring is not feasible in many institutions. Robotic assisted TCD (ra-TCD) was recently developed to overcome these constraints. The aim of this study was to evaluate the safety and feasibility of cerebral monitoring with a novel ra-TCD in acute neurovascular care. METHODS: This is a two-center prospective study conducted between August 2021 and February 2022 at Padua University Hospital (Padua, Italy) and Kepler University Hospital (Linz, Austria). Adult patients with conditions impacting cerebral hemodynamics or patients undergoing invasive procedures affecting cerebral hemodynamics were recruited for prolonged monitoring (> 30 min) of the middle cerebral artery with a novel ra-TCD (NovaGuide Intelligent Ultrasound, NeuraSignal, Los Angeles, CA). Manual TCD was also performed for comparison by an experienced operator. Feasibility and safety rates were recorded. RESULTS: A total of 92 patients (age: mean 68.5 years, range 36-91; sex: male 57 [62%]) were enrolled in the two centers: 54 in Padua, 38 in Linz. The examination was feasible in the majority of patients (85.9%); the head cradle design and its radiopacity hindered its use during carotid endarterectomy and mechanical thrombectomy. Regarding safety, only one patient (1.1%) reported a minor local edema due to prolonged probe pressure. Velocity values were similar between ra-TCD and manual TCD. CONCLUSIONS: This novel ra-TCD showed an excellent safety and feasibility and proved to be as reliable as manual TCD in detecting blood flow velocities. These findings support its wider use for cerebral hemodynamics monitoring in acute neurovascular care. However, further technical improvements are needed to expand the range of applicable settings.

10.
Cureus ; 16(8): e67446, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39314567

RESUMO

The right gastroepiploic artery (RGEA) is frequently used in coronary artery bypass grafting (CABG) for right coronary artery bypass requiring long-term patency. We experienced a case of upper-third advanced gastric cancer after CABG using RGEA. The absence of enlarged lymph nodes (LNs) or distant metastasis was confirmed through computed tomography (CT), and the RGEA graft remained patent according to coronary CT angiography. Based on these findings, the patient underwent robotic total gastrectomy while preserving the RGEA graft without infra-pyloric LN dissection. We suggested that caution should be exercised to avoid injury to the graft during gastrectomy, and robotic surgery could contribute to safely preserving the RGEA. We should consider the decision to dissect the infra-pyloric LN for the patient's safety and curability.

11.
J Vasc Surg Cases Innov Tech ; 10(6): 101605, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39314857

RESUMO

Pulmonary arteriovenous malformations create continuous shunting of unoxygenated blood through the lungs into the systemic circulation. These malformations are asymptomatic if small, but cause serious symptoms as they grow in size. Treatment primarily consists of endovascular embolization; lobectomy is preserved for recurring or endovascularly untreatable cases. We describe a case of a 24-year-old man who was first treated with coil embolization 10 years previously, with complete symptom resolution. However, more recently he noted recurrent exercise intolerance, with shortness of breath and hypoxemia. After repeat re-embolization, a computed tomography scan noted some persistent flow. Given the patient's young age, we considered resection as a definite therapy. The patient underwent an uncomplicated robot-assisted right lower lobectomy. Afterward, his symptoms resolved completely. In selected cases, robotic lobectomy for pulmonary arteriovenous malformation is feasible and safe.

12.
Eur Urol Open Sci ; 69: 1-4, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39314913

RESUMO

Over the past two decades, robotic surgery has seen substantial advances, with significant growth in novel platforms, particularly since 2019. As a high-volume center experienced with various robotic systems, we share our initial impressions of the new da Vinci 5 platform for robot-assisted radical prostatectomy. Key improvements include enhanced console ergonomics, more precise operative imaging, and the integration of smart commands for streamlined surgical control. Notably, force feedback instruments offer the potential for reduced tissue trauma, although further studies are needed to evaluate long-term outcomes and cost effectiveness. Our early experiences suggest that surgeons familiar with previous da Vinci models, particularly the Xi platform, will find the transition to the da Vinci 5 seamless, with minimal learning curve adjustments. Using propensity score matching, we compared perioperative outcomes for 50 da Vinci 5 RARP procedures (performed after the learning curve) with 150 da Vinci Xi cases. In our experience, optimal performance and perioperative outcomes were obtained with both models. Further studies are needed to identify any clinically significant advantages of one platform over the other. Patient summary: We compared outcomes for patients undergoing removal of the prostate using two different surgical robots (da Vinci Xi and da Vinci 5). Optimal operative outcomes were obtained with both robots, but further studies are needed to evaluate whether one robot is clinically superior to the other.

13.
Int J Med Robot ; 20(5): e2674, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39315572

RESUMO

BACKGROUND: We have previously reported a saline-linked bipolar clamp-crush technique as a novel robotic liver resection method. Herein, we present the surgical techniques and outcomes of robotic left hepatectomy using the Glissonean approach and our liver transection technique. METHODS: The key procedures included the following: (1) encircling the left Glissonean pedicle using the Tip-Up fenestrated grasper, (2) dissecting the liver parenchyma using the saline-linked bipolar clamp-crush technique, (3) moving the endoscope one trocar to the right to facilitate visualisation of the liver transection plane, and (4) stapling the left pedicle and left hepatic vein. Seven robotic left hepatectomies were performed. RESULTS: The median operative time and estimated blood loss were 395 min and 50 mL, respectively. The median length of postoperative hospital stay was 9 days. Pneumothorax was the only severe postoperative complication. CONCLUSIONS: Robotics left hepatectomy using the Glissonean approach and the saline-linked bipolar clamp-crush technique appears safe and feasible.


Assuntos
Hepatectomia , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Hepatectomia/métodos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fígado/cirurgia , Perda Sanguínea Cirúrgica/prevenção & controle , Neoplasias Hepáticas/cirurgia , Tempo de Internação , Adulto , Resultado do Tratamento , Instrumentos Cirúrgicos
14.
Clin Biomech (Bristol, Avon) ; 120: 106350, 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39317133

RESUMO

BACKGROUND: Restoring medial knee pivot kinematics post-total knee arthroplasty is widely recognized to enhance patient satisfaction. Our study investigates the kinematics of patients who received posterior stabilized implants via robotic-arm assisted surgery, specifically analyzing effects of implant alignment and soft tissue balance on pivot location. METHODS: Twelve high-functioning patients with unilateral posterior stabilizing knee implants underwent CT-guided robotic-arm assisted surgery. We then evaluated their knee kinematics using stereo radiography during gait, stair descent, lunge, seated knee extension and leg press. Femoral low-point condylar kinematics were used to calculate the transverse center of rotation, or pivot, using principal component analysis. Linear mixed effects regression was used to identify surgical parameters that influence pivot location across a flexion range. FINDINGS: Across all five activities a central pivot pattern emerged as the primary pivot location (40 %) followed by medial (25 %), no pivot (22 %) and lateral (14 %). Tibial medial resection depth and Tibial implant flexion-extension placement were significantly associated with shifting the pivot location laterally prior to cam-post engagement. Femoral implant external-internal implant placement, and medial compartment laxity in extension were significantly associated with shifting the pivot location laterally during the cam-post engagement, while femoral distal-lateral resection depth was associated with a medial shift. INTERPRETATION: Central and medial pivot locations are predominant in patients with posterior stabilized total knee arthroplasty, facilitated by robotic-arm assisted surgery. Despite significant associations between surgical parameters such as tibial medial resection depth and lateral compartment laxity with medial pivot, these variables explained a small portion of the variability in pivot location. This suggests that while surgical precision influences pivot kinematics, individual patient factors may play a more critical role, suggesting a need for further research into patient-specific biomechanics to optimize post-surgical outcomes.

15.
Artigo em Inglês | MEDLINE | ID: mdl-39317561

RESUMO

This study compared a multimodal image-guided robot and three-dimensionally (3D) printed templates for implanting iodine-125 (I125) radioactive seeds in patients with malignant tumours in the skull base and deep facial region. Seventeen patients who underwent I125 radioactive seed implantation between December 2018 and December 2019 were included. The operation time, intraoperative blood loss, and accuracy of seed implantation were compared between the multimodal image-guided robot-assisted implantation (experimental) group (n = 7) and 3D-printed template-assisted implantation (control) group (n = 10). In total, 291 seeds were implanted in the experimental group and 436 in the control group; the mean error of seed implantation accuracy was 1.95 ± 0.13 mm and 1.90 ± 0.08 mm, respectively (P = 0.309). The preparation time was 26.13 ± 5.28 min in the experimental group and 0 min in the control group, while the average operation time was 34.44 ± 6.39 min versus 43.70 ± 6.06 min, respectively. The intraoperative blood loss was 4.96 ± 1.76 ml (experimental) versus 8.97 ± 2.99 ml (control) (P = 0.123). Multimodal image-guided robot-assisted I125 radioactive seed implantation met the clinical requirements for treating malignant tumours in the skull base and deep facial regions.

16.
Surg Endosc ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39317908

RESUMO

INTRODUCTION: Many surgical fellowship programs incorporate robotic surgery, yet not all residency programs offer robotic training for residents. Given the variability of pre-fellowship robotic exposure, the goal of this study was to explore whether standardized robotic skills assessment would be useful to fellows at the start of their training. METHODS: In partnership with the Fellowship Council, we surveyed current fellows of accredited Thoracic, Colorectal, HPB, and Advanced GI/MIS/Bariatrics/Foregut Fellowship programs. Main outcome measurements included amount of robotic exposure during residency, fellows' robotic skills at the start of fellowship, and fellows' attitudes towards a standardized skills assessment. RESULTS: In total, 78 fellows completed the survey. Mean percentage of cases performed robotically during fellowship was 38.1% (SD ± 32.25%). From our respondents, 46% had no robotic curriculum during residency and 86.9% felt a standardized robotic curriculum during residency would have been beneficial. When asked if they started fellowship with adequate robotic skills to operate autonomously, 31% strongly agreed, but 24.4% strongly disagreed. The majority of fellows reported their fellowship program did not conduct an assessment of their robotic skills (71.5%), or provide a specific robotic curriculum (75.6%). On the other hand, 73.3% felt a formal proficiency assessment at the start of fellowship would be helpful for individualized support and training. CONCLUSIONS: Given the significant variability in resident exposure to robotic surgery, a standardized robotic curriculum during residency would likely be beneficial. Additionally, a robotic skills assessment at the start of fellowship could help provide a tailored training experience for fellows interested in this skillset.

17.
Updates Surg ; 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39297928

RESUMO

PURPOSE: Transabdominal preperitoneal (TAPP) ventral hernia repair requires incising the peritoneum from within the abdominal cavity, developing a flap, and placing a reinforcing mesh after fascial closure from the preperitoneal space. We present a novel adaptation to this technique that allows placement of preperitoneal mesh without entering the abdominal cavity. The robotic totally extra- and preperitoneal (R-PeTEP) access for ventral hernia repair is best suited for small to moderate sized ventral hernias with concomitant diastasis recti. METHODS: Our study is a retrospective review of all patients who underwent R-PeTEP from December 2022 to November 2023. A comprehensive description of the surgical technique is included. Patient demographics, hernia characteristics, as well as clinical outcomes are described. RESULTS: A total of 25 patients underwent R-PeTEP for ventral hernia repair with diastasis recti plication. The median age was 55 years (IQR 43.5-63) and 92% (n = 23) were male. The median ASA score was 2 (IQR 1-2) and the median BMI was 30.4 (IQR 29.3-32.8) with 64% (n = 16) percent having a BMI ≥ 30. Median hernia width was 3 cm (IQR 3-4), with a median diastasis recti width of 4 cm (IQR 2.6-4) and length of 15 cm (IQR 11.8-16). The median operative time was 120 min (IQR 116-134). All repairs were reinforced with permanent mesh. Sixty-eight percent of the patients (n = 17) were discharged on the same day. With a median follow-up of 30 days (IQR 16-107), 8% (n = 2) seromas, 16% (n = 4) developed clinically insignificant hematomas, and one patient (4%) developed ileus that was managed conservatively. CONCLUSION: This study establishes the feasibility and safety of R-PeTEP, which provides direct access to the preperitoneal space, avoiding disruption to the posterior rectus sheath, possibly reducing neurovascular bundle injuries, and omitting entry to the abdominal cavity. R-PeTEP facilitates wide flap creation for prosthetic overlap and allows for posterior plication of diastasis recti with little to no mesh fixation with overall excellent preliminary clinical outcomes.

18.
Cureus ; 16(8): e67262, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39301383

RESUMO

Minimally invasive liver surgery, particularly hepatectomy, has evolved significantly with the advent of laparoscopic and robotic techniques. These approaches offer potential benefits over traditional open surgery, including reduced postoperative pain, shorter hospital stays, faster recovery, and improved cosmetic outcomes. This comprehensive review aims to compare the operative efficiency and postoperative recovery outcomes of robotic and laparoscopic hepatectomy. It seeks to provide an in-depth analysis of the advantages and limitations of each technique, assess their cost-effectiveness, and explore emerging trends and future directions in minimally invasive liver surgery. A comprehensive literature search was conducted to identify studies comparing robotic and laparoscopic hepatectomy. The review includes an analysis of operative time, intraoperative blood loss, conversion rates, postoperative pain, length of hospital stay, complication rates, oncological outcomes, and overall cost. Additionally, advancements in technology and future research directions were explored to provide a comprehensive overview of the current landscape and future potential of these surgical techniques. Both robotic and laparoscopic hepatectomy have demonstrated comparable outcomes in terms of oncological safety and effectiveness. However, robotic hepatectomy offers advantages in terms of precision and dexterity, particularly in complex cases, due to its advanced visualization and instrumentation. Laparoscopic hepatectomy, while associated with shorter operative times and lower costs, is limited by technical challenges, especially in major liver resections. The review also highlights the increasing adoption of robotic systems, despite their higher costs and the need for specialized training. Robotic and laparoscopic hepatectomy are both viable options for minimally invasive liver surgery, each with distinct advantages and limitations. The choice between the two should be based on patient-specific factors, the complexity of the procedure, and the surgeon's expertise. Ongoing advancements in technology, including the integration of artificial intelligence and augmented reality, are expected to further refine these techniques, enhancing their efficacy and accessibility. Future research should focus on large-scale, multicenter trials to provide more definitive comparisons and guide clinical decision-making.

19.
Int J Med Robot ; 20(5): e2657, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39303291

RESUMO

BACKGROUND: The Shurui® system (SR-ENS-600) is a novel fully integrated single-port robotic system with bioinspired serpentine surgical manipulators and a camera. METHODS: This was a single-centre prospective case-series study according to the IDEAL stage 2a guidelines to evaluate the feasibility, safety and potential efficacy of the Shurui® system for gynaecological surgeries and to improve the operating process. RESULTS: Ten patients with a gradient of surgical difficulty who had indications for laparoscopic surgery and who volunteered to participate in a clinical trial were enrolled in the study. All 10 subjects successfully completed the procedure without converting to other procedures. No serious complications were reported at the 3-month follow-up. Subjects recover faster after surgery and are highly satisfied with the incision. CONCLUSIONS: Gynaecological single-site laparoscopic surgery with the Shurui® system was technically feasible for well-selected patients with minimal alterations in technique. Further prospective multicenter large-sample studies are necessary. REGISTRATION NUMBER: ChiCTR2300075431. URL: https://www.chictr.org.cn/showproj.html?proj=189995.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/instrumentação , Estudos Prospectivos , Procedimentos Cirúrgicos em Ginecologia/instrumentação , Procedimentos Cirúrgicos em Ginecologia/métodos , Laparoscopia/métodos , Laparoscopia/instrumentação , Adulto , Pessoa de Meia-Idade , Estudos de Viabilidade , Desenho de Equipamento , Resultado do Tratamento
20.
Artigo em Inglês | MEDLINE | ID: mdl-39292566

RESUMO

OBJECTIVES: There are little data within the literature regarding tracheobronchoplasty in the setting of the acute and chronically ill, morbidly obese or ventilator-dependent patients with tracheobronchomalacia. Short- and long-term outcomes are studied. METHODS: The series represents 12 tracheobronchomalacia patients with American Society of Anesthesiologists (ASA) physical status scores of 3-5. Candidacy was based on bronchoscopic findings during spontaneous respirations with >90% collapse of the trachea and both mainstem bronchi. We used dynamic computed tomography scan as an adjunct in those not mechanically ventilated. Our operative approach was a complete portal robotic approach for those outpatients (wheelchair dependent) and right thoracotomy for those who were already mechanically ventilated with 100% fraction of inspired oxygen with high pressure. Extracorporeal support was used in 2 patients. RESULTS: Patients who underwent robotic repair were discharged without complications. Two patients who were critically ill and required extracorporeal support for their surgeries were separated from extracorporeal membrane oxygenation on postoperative day 2. Three patients died at the follow-up. In 1 patient, the prolene mesh migrated into trachea and caused obstruction of the trachea and required removal with endobronchial techniques. CONCLUSIONS: The repair of tracheobronchomalacia in patients with multiple comorbidities and with severe life-threatening problems in or outside the intensive care unit may have improvement due to the ability to wean from positive pressure ventilation. Surgical technique and the utilization of mesh support in tracheobronchoplasty operations may need to be debated due to duration of the surgery in patients with severe comorbidities.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA