Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39463039

RESUMO

BACKGROUND: Provisional single stenting strategy (PSS) is a default strategy for percutaneous coronary intervention (PCI) of unprotected left main distal bifurcation lesions (ULMD). Previous study reported that a bifurcation angle change (BAC) between end diastole and systole was associated with outcomes after PCI with double stent strategy (DSS) for ULMD. However, there are no data comparing outcomes after PCI with PSS versus DSS according the degree of BAC. OBJECTIVES: We evaluated outcomes after PCI with PSS versus DSS for true ULMD with small and large BAC. METHODS: We identified 566 patients with true ULMD underwent PCI in three high-volume centers. We calculated the BAC in ULMD between end-diastole and systole before stenting with 2-dimensional quantitative coronary angiographic assessment. We defined small (BAC < 7.0°) and large BAC (≥7.0°) group. We compared clinical outcomes after PCI with PSS versus DSS in each cohort after propensity score adjustment. The primary endpoint was target-lesion failure (TLF), which was defined as a composite of cardiac death, target lesion revascularization, and myocardial infarction. RESULTS: In small BAC cohort, TLF rate was significantly lower in DSS group than in PSS group (12.5% vs. 20.1%, adjusted HR 0.45; 95% CI, 0.26-0.79; p = 0.006). In contrast, in large BAC cohort, TLF rate was significantly higher in DSS group than in PSS group (54.9% vs. 29.0%, adjusted HR 2.25; 95% CI, 1.50-3.38; p < 0.001). CONCLUSIONS: The TLF rate after PCI with DSS was significantly lower in true ULMD with small BAC compared to PSS even after propensity score adjustment. In contrast, it was significantly higher in those with large BAC.

2.
J Am Coll Cardiol ; 2024 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-39480379

RESUMO

BACKGROUND: Drug-eluting stents (DESs) with controlled antiproliferative drug release reduce restenosis risk, but durable polymers can delay healing and inhibit reendothelialization. The Firehawk biodegradable polymer sirolimus-eluting stent (BP-SES) has a fully biodegradable sirolimus-containing polymer coating localized to recessed abluminal grooves on the stent surface and delivers roughly one-third the drug dose of other DESs. OBJECTIVES: We report the primary results of the TARGET-IV NA (Firehawk Rapamycin Target Eluting Coronary Stent North American Trial) randomized controlled trial comparing clinical outcomes with BP-SES vs currently used second-generation DESs. METHODS: The TARGET-IV NA study was a prospective, multicenter, single-blind, 1:1 randomized noninferiority trial comparing the BP-SES with control in North America and Europe among patients undergoing percutaneous coronary intervention for chronic or acute coronary syndromes. The primary endpoint was target lesion failure (TLF) at 12 months (composite of cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization). The primary analysis (intention-to-treat) tested noninferiority of BP-SES vs control using an absolute margin of 3.85% and 1-sided α of 0.025. Noninferiority-powered secondary endpoints were tested in an optical coherence tomography substudy (endpoint: mean neointimal hyperplasia thickness) and an angiography substudy (endpoint: in-stent late lumen loss). RESULTS: A total of 1,720 patients (mean age 66 years; 74% male) with 2,159 lesions were randomly allocated to receive either BP-SES (860 patients, 1,057 lesions) or control second-generation DES (860 patients, 1,084 lesions). A total of 61% of patients presented with stable coronary disease, 32% had unstable angina, and 7% had non-ST-segment elevation myocardial infarction (NSTEMI) or recent ST-segment elevation myocardial infarction. The rate of TLF with BP-SES was noninferior to control at 12 months (3.4% vs 3.3%, absolute risk difference 0.13%, upper bound 97.5% CI: 2.03, Pnoninferiority < 0.0001). Cardiac death, myocardial infarction, and stent thrombosis rates were similar between groups. Angiographic follow-up was available in 104 patients (97.2% of those enrolled in the angiographic substudy) and 128 (94.1%) lesions. At 13 months, the powered secondary endpoint of mean in-stent late lumen loss was 0.149 ± 0.263 mm for BP-SES and 0.327 ± 0.463 mm for control (least squares mean difference: -0.178; 90% CI: -0.2943 to -0.0632; Pnoninferiority < 0.0001). The optical coherence tomography substudy included 37 patients (42 lesions) with no difference in mean neointimal hyperplasia thickness between groups at 13 months (Pnoninferiority = 0.01). CONCLUSIONS: The biodegradable polymer sirolimus-eluting stent was noninferior to currently used second-generation DES with regard to TLF at 1 year. (Firehawk® Rapamycin Target Eluting Coronary Stent North American Trial; NCT04562532).

3.
Diab Vasc Dis Res ; 21(5): 14791641241283939, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39311502

RESUMO

BACKGROUND: Diabetes mellitus is associated with higher risk of target lesion failure (TLF) after percutaneous coronary intervention. We studied the 5-year outcome in patients with diabetes mellitus treated with biodegradable polymer stents. METHODS: The SORT OUT VII was a randomised trial comparing the ultrathin sirolimus-eluting Orsiro stent (O-SES) and the biolimus-eluting Nobori stent (N-BES) in an all-comer setting. Patients (n = 2525) were randomised to receive O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). Endpoints were TLF (a composite of cardiac death, target-lesion myocardial infarction (MI), target lesion revascularization (TLR)), definite stent thrombosis and a patient related outcome (all-cause mortality, MI and revascularization) within 5 years. RESULTS: Patients with diabetes mellitus had higher TLF (20.6% vs 11.0%, (Rate ratio (RR) 1.85 95% confidence interval (CI): (1.42-2.40) and patient related outcome (42.0% vs 31.0%, RR 1.43 95% CI: (1.19-1.71)) compared to patients without diabetes. Among patients with diabetes mellitus, TLF after 5 years did not differ between O-SES and N-BES (21.2% vs 20.0%), RR 1.05 95% CI: (0.70-1.58), p = 0.81). Cardiac death, MI, TLR, and definite stent thrombosis did not differ between the groups. CONCLUSION: In patients with diabetes mellitus, 5-year outcomes were similar among patients treated with biodegradable polymer O-SES or N-BES. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01879358.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fatores de Tempo , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Fármacos Cardiovasculares/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Fatores de Risco , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Polímeros , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Infarto do Miocárdio/mortalidade
4.
Cureus ; 16(5): e59611, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38832189

RESUMO

Background and objective Diffuse coronary artery disease (CAD) is associated with extensive involvement of coronary arteries, necessitating the use of long (≥40 mm) drug-eluting stents (DES) based on the lesion length. However, these long DES can lead to complications such as in-stent restenosis (ISR) and stent thrombosis. This study aimed to assess the safety, efficacy, and one-year clinical outcomes of using long DES in patients with diffuse CAD undergoing PCI at a tertiary care hospital in north India. Methodology Patients with diffuse CAD undergoing PCI with long DES between January 2017 and June 2022 were included in the study. Baseline characteristics were recorded, and patients were followed up telephonically or in the outpatient department (OPD) at one, three, six, and 12 months following the PCI. The primary endpoint was the target lesion failure (TLF) rate, with secondary endpoints constituting all-cause mortality, major adverse cardiovascular events (MACE), subacute stent thrombosis, and ISR. Results A total of 200 patients were recruited and followed up for one year. The median age of the patients was 58 years (range: 48.25-63 years), and 82% were men. The most frequently stented artery was the left anterior descending (LAD, 48%), followed by the right coronary artery (RCA, 36%). A total of 388 stents (mean: 1.94 ±0.79) were implanted, including both long and short stents. The mean length and diameter of long stents were 43.64 ±3.58 mm and 3 ±0.37 mm, respectively. At the one-year follow-up, patients undergoing PCI with long DES ≥40 mm had an overall TLF rate of 5%, all-cause mortality of 6% (12 patients), MACE of 6% (12 patients), subacute stent thrombosis of 4% (eight patients), and ISR of 1% (two patients). A large proportion of patients (90%) had an uneventful follow-up of up to a year. At the one-year follow-up, all 10 (5%) patients with a primary outcome had a smaller stent diameter than those without a primary outcome (2.5 ±0.25 mm vs. 3.03 ±0.35 mm, p=0.015). Conclusions Our results suggest that using extremely long stents (>40 mm) for diffuse coronary lesions is safe, efficacious, and associated with relatively low event rates. In addition, the stent diameter has a substantial correlation with the primary outcome. Further studies with larger sample sizes as well as longer follow-up periods are required to validate our findings.

5.
Cureus ; 16(3): e56346, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38633944

RESUMO

BACKGROUND: Drug-eluting stents (DES) are the major treatment option in percutaneous coronary intervention (PCI). Recently, drug-coated balloon (DCB) utilization has been increasing globally, leading to the expected new strategy of "stent-less PCI." This study aimed to evaluate the one-year outcome of DCB compared to DES. METHODS: Patients who underwent initial PCI for de novo lesions in our institution from January 2018 to December 2021 (n=337) were subjected to retrospective analysis. Among them, 75 patients were treated with DCB, while 262 patients were treated with DES. Target lesion failure (TLF) was evaluated during the follow-up period. RESULTS: The proportion of PCIs for ACS was significantly lower in the DCB group (DCB, n=23, 30.7% vs. DES, n=143, 54.6%; p=0.001). The median device diameter and length in the DES group were larger than those in the DCB group (DCB, 2.60 mm vs. DES, 2.98 mm; p<0.001; DCB, 19.1 mm vs. DES, 25.2 mm; p<0.001). There was no significant difference between the DCB and DES groups in lesion calcification. The proportion of ostial lesions was significantly higher in the DCB group (DCB, n=13, 17.3% vs. DES, n=21, 8.0%; p=0.018). The cumulative rate of TLF (DCB, n=5, 6.7% vs. DES, n=18, 6.9%; p=0.951) did not significantly differ between the DCB and DES groups. CONCLUSION: DCB may be as effective a strategy as DES in the patient who underwent initial PCI for a de novo lesion.

6.
Herz ; 49(5): 361-370, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38656396

RESUMO

BACKGROUND: This study aimed to evaluate the long-term outcomes of double kissing crush stenting (DKC) and mini-culotte technique (MCT) in patients with complex bifurcation lesions. METHODS: This retrospective study enrolled 236 patients who underwent percutaneous coronary intervention (PCI) for complex coronary bifurcation disease between January 2014 and November 2022. The primary endpoint was target lesion failure (TLF), defined as the combination of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). The secondary endpoint was major cardiovascular and cerebral events (MACCE) including all-cause death, MI, TLR, stroke, or stent thrombosis. The regression models were adjusted by applying the inverse probability weighted (IPW) approach to reduce treatment selection bias. RESULTS: The initial management strategy was DKC in 154 (65.3%) patients and MCT in 82 (34.7%) patients (male: 194 [82.2%], mean age: 60.85 ± 10.86 years). The SYNTAX scores were similar in both groups. The rates of long-term TLF and MACCE rates were 17.4% and 20%, respectively. The rate of TLF (26.8% vs. 12.3%, p = 0.005) was higher in patients treated with MCT than those treated with the DKC technique, mainly driven by more frequent TLR (15.9% vs. 7.1%, p = 0.035). The long-term TLF and MACCE rates were notably lower in the DKC group compared to the others: adjusted hazard ratio (HR; IPW): 0.407, p = 0.009 for TLF, and adjusted HR(IPW): 0.391 [95% CI: 0.209-0.730], p = 0.003 for MACCE. CONCLUSION: At long-term follow-up, the rates of TLF and MACCE were 17.4% and 20%, respectively. However, long-term TLF was significantly higher in patients treated with MCT than those treated with the DKC technique, primarily due to a more frequent occurrence of clinically driven TLR.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/instrumentação , Estudos Retrospectivos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Idoso , Stents Farmacológicos , Stents
7.
Catheter Cardiovasc Interv ; 103(2): 276-285, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38091338

RESUMO

BACKGROUND: Patients with acute coronary syndromes (ACS) may have worse outcomes after percutaneous coronary intervention compared to patients without ACS. AIMS: To compare 5-year efficacy and safety outcomes in patients with and without ACS treated with biodegradable polymers, the ultrathin strut sirolimus-eluting Orsiro stent (O-SES) or the biolimus-eluting Nobori stent (N-BES). METHODS: The Scandinavian Organisation for Randomized Trials with Clinical Outcome VII is a randomized trial comparing O-SES and N-BES in an all-comer setting. Of 2525 patients, 1329 (53%) patients had ACS and 1196 (47%) patients were without ACS. Endpoints were target lesion failure (TLF) (a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization) and definite stent thrombosis within 5 years. RESULTS: At 5-year follow-up, TLF did not differ significantly between patients with and without ACS (12.3% vs. 13.2%; rate ratio (RR) 1.00; 95% confidence interval (CI): 0.70-1.44), whereas the risk of definite stent thrombosis was increased in patients with ACS (2.3% vs. 1.3; RR: 2.01 [95% CI: 1.01-3.98]). In patients with ACS, the rate of TLF was similar between O-SES and N-BES (12.4% vs. 12.3%; RR: 1.02; 95% CI: 0.74-1.40). The reduced risk of definite stent thrombosis in O-SES treated ACS patients within the first year (0.2% vs. 1.6%; RR: 0.12; 95% CI: 0.02-0.93) was not maintained after 5 years (1.8% vs. 2.7%; RR: 0.77; 95% CI: 0.37-1.63). CONCLUSION: Patients with ACS had an increased risk of stent thrombosis regardless of the stent type used. Long-term outcomes were similar for ACS patients treated with O-SES or N-BES at 5 years.


Assuntos
Síndrome Coronariana Aguda , Ácidos Alcanossulfônicos , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Trombose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Fatores de Risco , Resultado do Tratamento , Stents Farmacológicos/efeitos adversos , Implantes Absorvíveis , Desenho de Prótese , Fármacos Cardiovasculares/efeitos adversos , Trombose Coronária/etiologia , Stents/efeitos adversos , Polímeros , Intervenção Coronária Percutânea/efeitos adversos
8.
Eur Heart J Digit Health ; 4(6): 433-443, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38045434

RESUMO

Aims: Central to the practice of precision medicine in percutaneous coronary intervention (PCI) is a risk-stratification tool to predict outcomes following the procedure. This study is intended to assess machine learning (ML)-based risk models to predict clinically relevant outcomes in PCI and to support individualized clinical decision-making in this setting. Methods and results: Five different ML models [gradient boosting classifier (GBC), linear discrimination analysis, Naïve Bayes, logistic regression, and K-nearest neighbours algorithm) for the prediction of 1-year target lesion failure (TLF) were trained on an extensive data set of 35 389 patients undergoing PCI and enrolled in the global, all-comers e-ULTIMASTER registry. The data set was split into a training (80%) and a test set (20%). Twenty-three patient and procedural characteristics were used as predictive variables. The models were compared for discrimination according to the area under the receiver operating characteristic curve (AUC) and for calibration. The GBC model showed the best discriminative ability with an AUC of 0.72 (95% confidence interval 0.69-0.75) for 1-year TLF on the test set. The discriminative ability of the GBC model for the components of TLF was highest for cardiac death with an AUC of 0.82, followed by target vessel myocardial infarction with an AUC of 0.75 and clinically driven target lesion revascularization with an AUC of 0.68. The calibration was fair until the highest risk deciles showed an underestimation of the risk. Conclusion: Machine learning-derived predictive models provide a reasonably accurate prediction of 1-year TLF in patients undergoing PCI. A prospective evaluation of the predictive score is warranted. Registration: Clinicaltrial.gov identifier is NCT02188355.

9.
Cardiovasc Diabetol ; 22(1): 283, 2023 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-37865782

RESUMO

BACKGROUND: Early diagnosis and treatment effectiveness of early-onset coronary artery disease (EOCAD) are crucial, and non-invasive predictive biomarkers are needed for young adults. We aimed to evaluate the usefulness of the triglyceride-glucose (TyG) index, a novel marker of insulin resistance, in identifying young CAD patients and predicting their risk of developing target lesion failure (TLF). METHODS: We recruited EOCAD patients (luminal narrowing ≥ 70%) and controls free from CAD (luminal narrowing < 30%), both aged 45 years or younger, from 38 hospitals in China between 2017 and 2020. EOCAD patients who underwent successful percutaneous coronary intervention were followed for incident TLF. TyG index was defined as Ln [fasting triglyceride (mg/dL) × fasting blood glucose (mg/dL)/2]. We used logistic regression and Cox proportional hazards modeling to evaluate the association of TyG index with prevalent EOCAD and incident TLF, respectively. The discriminatory ability of TyG index was assessed by the area under the receiver-operating characteristic curve (AUC). RESULTS: Among the included 1513 EOCAD patients (39.6 ± 4.4 years, 95.4% male) and 1513 age-matched controls (39.0 ± 4.4 years, 46.4% male), TyG index was positively associated with the prevalence of EOCAD (adjusted odds ratio: 1.40, 95% confidence interval [CI] 1.23-1.60, per standard deviation [SD] increase in TyG index). The addition of TyG index to an empirical risk model provided an improvement in diagnostic ability for EOCAD, with a net reclassification improvement of 0.10 (95% CI 0.03-0.17, p = 0.005). During a medium of 33 month (IQR: 31-34 months) follow-up, 43 (3.3%) patients experienced TLF. Multivariate Cox regression model revealed that TyG index was an independent risk factor for TLF (adjusted hazard ratio [HR]: 2.410, 95% CI 1.07-5.42 comparing the top to bottom TyG index tertile groups; HR: 1.30, 95% CI 1.01-1.73, per SD increase in TyG index). Compared with a model of conventional risk factors alone, the addition of the TyG index modestly improved the AUC (0.722-0.734, p = 0.04) to predict TLF. CONCLUSIONS: TyG index is positively associated with prevalent EOCAD and incident TLF. TyG index appeared to be a valuable component of future efforts to improve CAD risk stratification and TLF outcome prediction among young adults.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Humanos , Masculino , Adulto Jovem , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Glucose , Glicemia , Triglicerídeos , Fatores de Risco , Biomarcadores , Medição de Risco
10.
BMC Cardiovasc Disord ; 23(1): 496, 2023 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-37805479

RESUMO

BACKGROUND: Cell division control 42 (CDC42) regulates atherosclerosis, blood lipids, and inflammation and thus affects coronary artery disease (CAD), but its utility in drug-coated balloon (DCB)-treated small-vessel CAD (SV-CAD) patients is unclear. This study intended to evaluate the change and prognostic role of CDC42 in SV-CAD patients underwent DCB. METHODS: Serum CDC42 was measured by enzyme-linked immunosorbent assay in 211 SV-CAD patients underwent DCB at baseline, day (D) 1, D3, and D7, as well as in 50 healthy controls (HCs). RESULTS: CDC42 was decreased in SV-CAD patients compared to HCs (P < 0.001), and it was negatively associated with total cholesterol (P = 0.015), low-density lipoprotein cholesterol (P = 0.003), C-reactive protein (P = 0.001), multivessel disease (P = 0.020), and American college of cardiology/American heart association type B2/C lesions (P = 0.039) in SV-CAD patients. Longitudinally, CDC42 decreased from baseline to D1 and then gradually increased to D7 (P < 0.001) in SV-CAD patients after DCB. Interestingly, high CDC42 (cut-off value = 500 pg/mL) at baseline (P = 0.047), D3 (P = 0.046), and D7 (P = 0.008) was associated with a lower accumulating target lesion failure (TLF) rate; high CDC42 at D3 (P = 0.037) and D7 (P = 0.041) was related to a lower accumulating major adverse cardiovascular event (MACE) rate in SV-CAD patients underwent DCB. Importantly, CDC42 at D7 (high vs. low) independently predicted lower accumulating TLF (hazard ratio (HR) = 0.145, P = 0.021) and MACE (HR = 0.295, P = 0.023) risks in SV-CAD patients underwent DCB. CONCLUSIONS: Circulating CDC42 level relates to milder disease conditions and independently estimates lower risks of TLF and MACE in SV-CAD patients underwent DCB, but further validation is still needed.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Colesterol
11.
Am J Cardiol ; 206: 73-78, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37683582

RESUMO

Patients with diabetes mellitus (DM) are at higher risk of restenosis and stent thrombosis after percutaneous coronary intervention (PCI) and drug-eluting stent (DES) positioning. Whether drug-coated balloons (DCB) can offer any benefit in this subset of patients has been seldom cleared out and was the aim of the present propensity-matched cohort study, that compared the prognostic impact of DCB versus DES in patients with DM who underwent PCI. Patients with DM enrolled in the NOvara-BIella-TREnto (NOBITRE) Registry were identified and matched according to propensity score, to a control population of patients with DM treated with DES. The primary study end point was the occurrence of major adverse cardiovascular events (MACEs). A total of 150 patients were identified in the DCB group and matched with 150 DES-treated patients. Patients treated with DCB displayed more often a previous cardiovascular history and received a more complete pharmacological therapy. Target vessel diameter and the percentage of stenosis were lower in patients with DCB, whereas binary in-stent restenosis was more common (p <0.001, p = 0.003, and p <0.001, respectively). Paclitaxel-eluting balloon represented the most common strategy in the DCB group, whereas Zotarolimus-eluting stents were used in half of the DES population. At a median follow-up of 545.5 days, MACE occurred in 54 (19.4%) of patients, with no difference according to the PCI strategy (21.6% vs 17.3%, adjusted hazard ratio [95% confidence interval] 1.51 [0.46 to 4.93], p = 0.50). Major ischemic end points were slightly increased in patients treated with DCB, whereas overall death was significantly reduced (3.6% vs 10.9%; adjusted hazard ratio [95% confidence interval] 0.27 [0.08 to 0.91], p = 0.03). In conclusion, the present propensity-matched study shows that, in patients with DM who underwent PCI for in-stent restenosis or de novo lesions, the use of DCB is associated with a similar rate of MACE and a modest increase in target lesion failure, but a significantly improved survival as compared with DES.

12.
Cardiovasc Revasc Med ; 57: 53-59, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37543502

RESUMO

BACKGROUND: The magnesium Magmaris scaffold is the latest resorbable technology with low thrombogenicity, short scaffolding time, and almost complete resorption at 12 months (95 %). As compared with stable coronary artery disease (SCAD), acute coronary syndrome (ACS) is associated with increased risk of adverse clinical outcome after percutaneous coronary intervention. We analyzed the data of the Magmaris Multicenter Italian Registry to compare clinical outcomes in SCAD versus ACS patients. METHODS: We evaluated the 24-month rates of target lesion failure (TLF) and scaffold thrombosis (ST). Device implantation procedures were performed according to the manufacturer's recommendations (proper patient/lesion selection, pre-dilatation, proper scaffold sizing, and post-dilatation). Dual antiplatelet therapy was terminated after 12 months. RESULTS: Data from 207 patients (145 SCAD and 62 ACS) were collected from July 2016 to June 2018. The 2-year follow-up compliance was 92.8 % (192 patients). At 2 years, TLF rates were 7.4 % in the SCAD group and 8.8 % in the ACS group (p = 0.7); ST rates were 0 % in the SCAD group and 1.8 % in the ACS group (p = 0.1). CONCLUSION: The 2-year clinical results from the Magmaris Multicenter Italian Registry are favorable in terms of TLF and ST, indicating the safety and effectiveness of the Magmaris scaffold in both SCAD and ACS patients.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Trombose , Humanos , Implantes Absorvíveis , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Trombose/etiologia , Sistema de Registros , Itália
13.
Int J Cardiol ; 387: 131149, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37423566

RESUMO

BACKGROUND: Drug-coated balloon (DCB) became a potential treatment option for patients with acute coronary syndrome (ACS); however, factors associated with target lesion failure (TLF) remain uncertain. METHODS: This retrospective, multicentre, observational study included consecutive ACS patients who underwent optical coherence tomography (OCT)-guided DCB treatment. Patients were divided into two groups according to the occurrence of TLF, a composite of cardiac death, target vessel-related myocardial infarction, and ischemia-driven target lesion revascularisation. RESULTS: We enrolled 127 patients in this study. During the median follow-up period of 562 (IQR: 342-1164) days, 24 patients (18.9%) experienced TLF, and 103 patients (81.1%) did not. The cumulative 3-year incidence of TLF was 22.0%. The cumulative 3-year incidence of TLF was the lowest in patients with plaque erosion (PE) (7.5%), followed by those with rupture (PR) (26.1%) and calcified nodule (CN) (43.5%). Multivariable Cox regression analysis revealed that plaque morphology was independently associated with TLF on pre-PCI (percutaneous coronary intervention) OCT, and residual thrombus burden (TB) was positively associated with TLF on post-PCI OCT. Further stratification by post-PCI TB revealed a comparable incidence of TLF in patients with PR (4.2%) to that of PE if the culprit lesion had a smaller post-PCI TB than the cut-off value (8.4%). TLF incidence was high in patients with CN, regardless of TB size on post-PCI OCT. CONCLUSIONS: Plaque morphology was strongly associated with TLF for ACS patients after DCB treatment. Residual TB post-PCI might be a key determinant for TLF, especially in patients with PR.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/métodos , Estudos Retrospectivos , Angiografia Coronária/métodos , Resultado do Tratamento , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/cirurgia , Placa Aterosclerótica/etiologia , Vasos Coronários/patologia , Doença da Artéria Coronariana/terapia
14.
Cardiovasc Revasc Med ; 54: 47-56, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37150642

RESUMO

BACKGROUND: The use of drug-coated balloon in the management of true bifurcation lesions appears to be an attractive option to reduce the rate of stent thrombosis and restenosis particularly at the level of the side branch ostium. We aim to assess the safety and the efficacy of a hybrid approach combining a drug-eluting stent in the main branch and a drug-coated balloon to treat the side branch ostium in patients with de novo true bifurcation. METHODS: From September 2020 to March 2022, 45 patients with a de novo true bifurcation lesion Medina (1.1.1) or Medina (0.1.1) were enrolled. All patients underwent a percutaneous coronary intervention with the hybrid approach. Clinical assessment with functional stress imaging test was scheduled at 6 months. In case of documented ischemia, coronary angiography was performed. The primary endpoint was the composite of target lesion failure at 6 months including cardiac death, target vessel MI or ischemia-driven target lesion revascularization. The secondary endpoints were technical success, defined by performing the percutaneous coronary intervention without an additional drug-eluting stent at the level of the side branch ostium, and clinical success, defined by a technical success associated with the absence of severe complications during in-hospital phase. RESULTS: The immediate results show a technical success of the procedure in the majority of cases (88.9 %) with a low rate of bailout side branch stenting (11.1 %). The clinical success was obtained in 86.7 % and only one patient experienced a severe in-hospital complication. A side branch ostial lesion length > 10 mm was the only independent predictor of clinical failure of the procedure (OR 12.49, 95 % CI 1.17-133.6; p = 0.037). At 6 months, the TLF was low and occurred in 1 patient (2.2 %). No cardiac death was observed. No TVMI was observed. Importantly, at 6 months, no side branch thrombosis was observed. CONCLUSION: The use of a hybrid approach combining a drug-eluting stent in the main branch and a drug-coated balloon in the side branch to treat true bifurcation lesions appears to be safe and efficient with few immediate complications and with satisfactory results at mid-term follow up.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Stents Farmacológicos , Humanos , Stents Farmacológicos/efeitos adversos , Paclitaxel/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Resultado do Tratamento , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Reestenose Coronária/etiologia
15.
J Cardiol ; 81(1): 76-82, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36163312

RESUMO

BACKGROUND: This head-to-head, multicenter, randomized trial investigated the safety and efficacy of Restore (Cardionovum, Bonn, Germany) drug-coated balloon (DCB) angioplasty in an Asian patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR). METHODS: A total of 240 patients with coronary DES-ISR were treated with Restore DCB or with SeQuent® Please (Braun, Melsungen, Germany) DCB. This trial used nine-month in-segment late lumen loss (LL) as the primary endpoint. Secondary endpoints included two-year clinical event rates. RESULTS: Patient, lesion, and procedural characteristics in both treatment groups were similar. Nine-month in-segment LL was 0.38 ±â€¯0.50 mm with Restore vs. 0.35 ±â€¯0.47 mm with SeQuent® Please (p for non-inferiority = 0.02). The two-year follow-up rates were 95.8 % (115/120) in the Restore group and 94.2 % (113/120) in the SeQuent® Please group. Both groups had similar one- and two-year target lesion failure (TLF) rates (13.3 % vs. 12.6 %; p = 0.87 at one year, 14.8 % vs. 15.0 %; p = 1.0 at two years). Moreover, the all-cause mortality and myocardial infarction rates were 0 and 3.5 % (4/120) in the Restore group and 0.9 % (1/120) and 3.5 % (4/120) in the SeQuent® Please group, respectively. Additional analyzing of vessel quantitative flow ratio (QFR) did also show noninferior outcomes for one explicit treatment bunch. CONCLUSIONS: The two-year follow-up indicated sustained long-term clinical safety and efficacy for both devices on the basis of QFR value.


Assuntos
Fármacos Cardiovasculares , Reestenose Coronária , Stents Farmacológicos , Humanos , Reestenose Coronária/terapia , Reestenose Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Materiais Revestidos Biocompatíveis , Paclitaxel , Resultado do Tratamento , Fatores de Tempo
16.
Cardiol J ; 30(2): 196-203, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34490602

RESUMO

BACKGROUND: Covered coronary stent (CS) implantation is associated with a high risk for in-stent restenosis (ISR) and stent thrombosis (ST). We describe the outcomes after overstenting ("burying") CS using contemporary drug-eluting stents (DES). METHODS: We analyzed short- and long-term outcomes of consecutive patients who had had a CS implanted, which was consecutively covered ("buried") with a third-generation DES. CSs were primarily post-dilated and then covered with a longer DES overlapping the proximal and distal edges of the CS. To ensure optimal stent expansion and appositions, all lesions were post-dilated using adequately sized non-compliant balloons. RESULTS: Between 2015 and 2020, 23 patients (mean age 67 ± 14 years, 74% males) were treated using this novel approach. Reasons for implanting CS included treatment of coronary aneurysms (n = 7; 30%), coronary perforations (n = 13; 57%), and aorto-ostial dissections (n = 3; 13%). All CSs were successfully deployed, and no peri-procedural complications occurred. The median time of follow-up was 24.5 (interquartile range [IQR] 11.7-37.9) months. All patients had a 1-month follow-up (FU) and 19/23 (83%) patients had 12-month FU (FU range 1-60 months). No probable or definite STs occurred, and no cardiovascular deaths were observed. Among patients undergoing angiographic FU (11/23 [48%]), 1/23 showed angiographically significant ISR 6 months post CS implantation. CONCLUSIONS: Burying a coronary CS under a DES appears to be a safe and promising strategy to overcome the limitations of the currently available CS devices, including a relatively high risk for target lesion failure due to ISR and ST.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Trombose , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Stents Farmacológicos/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Angiografia Coronária/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Stents/efeitos adversos , Trombose/etiologia , Intervenção Coronária Percutânea/efeitos adversos
17.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378691

RESUMO

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Assuntos
Síndrome Coronariana Aguda , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Doença da Artéria Coronariana/terapia , Fatores de Risco , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Fatores de Tempo , Desenho de Prótese , Infarto do Miocárdio/etiologia , Stents Farmacológicos/efeitos adversos
18.
Rev Cardiovasc Med ; 24(2): 53, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39077417

RESUMO

Background: In patients undergoing percutaneous coronary intervention (PCI), drug eluting stents (DES) are currently the standard of care. Stent design and alloy composition, biocompatibility of the drug-eluting polymer coating, the antiproliferative agent properties and release are the three main characteristics that affects DES performance. Cre8 (Alvimedica, Istanbul, Turkey) is a polymer-free amphilimus-eluting stents (PF-AES). In this study, we aimed to investigate the clinical efficacy and safety of Cre8 DES in daily cardiology practice. Methods: Patients presenting with chronic coronary syndrome (CCS) or acute coronary syndrome (ACS) including unstable angina pectoris (USAP), myocardial infarction with and without ST-segment elevation and treated with PCI using Cre8 DES between December 2015 and 2016 were retrospectively analyzed in this study. Results: Between December 2015 and 2016, 808 lesions of 664 patients treated with Cre8 DES in a single center were included in this retrospective analysis. The mean age of study group was 60 years (between 33 and 93 years) and were predominantly consisting of male patients (79.4%). The median follow-up duration was 487 days (min: 30 days, max: 919 days) and two-thirds of all patients presented with ACS. The culprit lesion was on left anterior descending artery (LAD) (40.5%) and right coronary artery (RCA) (25.9%) in most of the patients. The procedural success rate was 97.3%. Most of the lesions were type B1 (40.6%) according to American College of Cardiology/American Heart Association (ACC/AHA) coronary lesion classification. The device oriented primary end-point defined as target lesion failure (TLF) occurred in 52 (6.4%) of 808 lesions. The primary safety end-point was cardiac death in 20 patients (3.0%) and target vessel myocardial infarction in 2 patients (0.3%). Target vessel revascularization (TVR) occurred in 29 patients (4.4%) as primary safety endpoint. Multivariable logistic regression analysis revealed diabetes mellitus and ejection fraction as the predictors of mortality and device oriented primary end-point. Conclusions: This trial revealed clinical efficacy and safety of Cre8 stents in real world practice. Device oriented primary end points were similar with previous studies which are randomized, open label in nature and showed the efficacy and safety of Cre8 stent towards latest generation DES.

19.
Rev Cardiovasc Med ; 24(8): 221, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39076703

RESUMO

Background: The DynamX Novolimus-Eluting Coronary Bioadaptor System ( DynamX ® Bioadaptor) has uncaging elements that disengage after the resorption of the polymer coating, aiming to restore vessel function in the treated segment and to avoid long-term adverse outcomes associated with the permanent caging of the coronary artery seen with conventional stenting. Methods: This prospective, multicenter, single-arm first-in-human study enrolled 50 patients in Belgium and Italy who were treated with the DynamX Bioadaptor. Eligible patients had de novo lesions in coronary arteries measuring between 2.5 and 3.5 mm in diameter and ≤ 24 mm in length. Clinical follow-up was performed up to 36 months. This analysis includes the intention-to-treat population and is based on data available. The preclinical studies include optical coherence tomography (OCT) analyses of 5 DynamX Bioadaptors implanted in 3 mini Yucatan pigs (at 3, 12 and 24 months), and assessment of smooth muscle cell gene expression profile in 8 pigs of which each was implanted with the DynamX Bioadaptor and the Xience drug-eluting stent. To assess the gene expression profile by quantitative real-time polymerase chain reaction, animals were sacrificed at 3, 6, 9 and 12 months. Results: Target lesion failure at 36 months was 8.7% (4/46), consisting of one clinically-driven target lesion revascularization and 3 cardiac deaths (all site-reported to be unrelated to the device or procedure). There were no additional target vessel revascularization and no definite or probable scaffold thrombosis. Preclinical data confirmed late lumen enlargement (from 7.02 ± 1.31 mm 2 at baseline to 8.46 ± 1.31 mm 2 at 24 months) and identified an increased expression of contractile genes around 9 months compared to a conventional drug-eluting stent. Conclusions: The DynamX Bioadaptor demonstrated very good 36-month clinical outcomes, highlighted by the absence of target-vessel myocardial infarction and definite or probable device thrombosis, and only one target lesion revascularization up to 36 months. These data are supported by preclinical studies that showed late lumen enlargement by OCT and an increased expression of contractile genes around 9 months compared to conventional drug-eluting stents, indicating faster vessel healing. Larger clinical studies are necessary to compare outcomes against contemporary drug-eluting stents. Clinical Trial Registration: https://clinicaltrials.gov/: NCT03429894.

20.
J Am Heart Assoc ; 11(24): e025275, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36515253

RESUMO

Background Use of the modified American College of Cardiology (ACC)/American Heart Association (AHA) lesion classification as a prognostic tool to predict short- and long-term clinical outcomes after percutaneous coronary intervention in the modern drug-eluting stent era is uncertain. Methods and Results Patient-level data from 7 prospective, randomized trials were pooled. Clinical outcomes of patients undergoing single lesion percutaneous coronary intervention with second-generation drug-eluting stent were analyzed according to modified ACC/AHA lesion class. The primary end point was target lesion failure (TLF: composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization). Clinical outcomes to 5 years were compared between patients treated for noncomplex (class A/B1) versus complex (class B2/C) lesions. Eight thousand five hundred sixteen patients (age 63.1±10.8 years, 70.5% male) were analyzed. Lesions were classified as A, B1, B2, and C in 7.9%, 28.5%, 33.7%, and 30.0% of cases, respectively. Target lesion failure was higher in patients undergoing percutaneous coronary intervention of complex versus noncomplex lesions at 30 days (2.0% versus 1.1%, P=0.004), at 1 year (4.6% versus 3.0%, P=0.0005), and at 5 years (12.4% versus 9.2%, P=0.0001). By multivariable analysis, treatment of ACC/AHA class B2/C lesions was significantly associated with higher rate of 5-year target lesion failure (adjusted hazard ratio, 1.39 [95% CI, 1.17-1.64], P=0.0001) driven by significantly higher rates of target vessel myocardial infarction and ischemia-driven target lesion revascularization. Conclusions In this pooled large-scale analysis, treating complex compared with noncomplex lesions according to the modified ACC/AHA classification with second-generation drug-eluting stent was associated with worse 5-year clinical outcomes. This historical classification system may be useful in the contemporary era for predicting early and late outcomes following percutaneous coronary intervention.


Assuntos
Cardiologia , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Estudos Prospectivos , Fatores de Risco , Ensaios Clínicos Controlados Aleatórios como Assunto , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA