1.
Heliyon ; 10(12): e32713, 2024 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-39027458

RESUMO

Mg-based and Zn-based biodegradable materials have the potential to become the next-generation implant materials to treat bone diseases, because of their desired degradation and mechanical properties. This article reviews the status of these implant materials. The required properties of biodegradable materials such as biodegradability, mechanical properties, and biocompatibility for performance evaluation were briefly discussed. The influence of fabrication techniques, microstructure, alloying elements, and post-processing techniques on the properties of Mg and Zn-based materials was addressed. The degradation mechanism by dissolution, oxidation, and interaction with human body cells was discussed. The biocompatibility of Mg and Zn-based biodegradable materials was analyzed. The significance of in vitro and in vivo biocompatibility testing was highlighted, emphasizing the superiority of in vivo results over cell line studies. This article identifies the many Mg and Zn-based biodegradable materials and summarizes the key findings.

2.
J Colloid Interface Sci ; 668: 50-58, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38669995

RESUMO

The ever-growing requirement for electrochemical energy storage has exacerbated the production of spent batteries, and the recycling of valuable battery components has recently received a remarkable attention. Among all battery components, copper foil is widely utilized as a current collector for stable zinc platting and stripping in zinc metal batteries (ZMBs) due to the perfect lattice matching of between metal copper and zinc, which is accompanied by the formation of multiple copper-zinc alloy components during the cycling process. Herein, a novel "two birds with one-stone" strategy through a one simple heat treatment step to revive the discarded copper foil in zinc metal battery is reported to further obtain a lithiophilic current collector (CuxZny-Cu) with multiple copper-zinc alloy components on the surface of the discarded copper foil. Such revived CuxZny-Cu current collector greatly reduces the lithium nucleation overpotential and realizes uniform lithium deposition and further inhibits lithium dendrites growth. The formed multiple CuxZny alloy phases on the surface of discarded copper foil exhibit a low Li nucleation overpotential of only 15 mV at 0.5 mA cm-2 for the first cycle. Moreover, such a CuxZny-Cu current collector could achieve stable cycle for 220 cycles at 0.5 mA cm-2 and 110 cycles at 1 mA cm-2 with a Li plating capacity of 1 mAh cm-2. Theoretical calculations indicate that, compared with pure Cu foil, the formed multiple alloy components of CuZn5, CuZn8, Cu0.61Zn0.39 and CuZn have low adsorption energy of -2.17, -2.55, -2.16 and -2.35 eV with lithium atoms, respectively, which result in reduced lithium nucleation overpotential. The full cell composed of CuxZny alloy current collector with deposition of 5 mAh cm-2 metal Li anode coupled with LiFePO4 (LFP) cathode exhibits a reversible capacity of 125.6 mAh/g after 110 cycles at a current of 0.5 C with capacity retention of 85.1 %. This work proposed a promising strategy to regenerate the discarded copper foil in rechargeable batteries.

3.
Materials (Basel) ; 16(23)2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38068230

RESUMO

The objective of this study was to formulate dip coatings, incorporating casein, NaOH, and nanocrystalline hydroxyapatite (nanoHAp), with self-healing properties for application on ZnMg3.2 wt.% alloy in the field of biomedical applications. This study hypothesizes that the self-healing mechanism within the layer will impede substrate degradation by progressively filling defects where chlorides from simulated body fluids intervene. Furthermore, it aims to mitigate potential damage effects during the implantation process by the layer's self-healing capabilities. The research focused on the dip-coating process parameters and chemical composition of baths for producing casein coatings on Zn alloy surfaces. This study investigated the impact of casein and NaOH concentration, along with the immersion time of ZnMg3.2 wt.% samples in the coating bath, on the self-healing capability of the coating under simulated human body fluid conditions (Ringer's solution, temperature: 37 °C). Effective technology was developed by selecting specific chemical compositions and immersion times in the coating bath, enhancing the self-healing progress against coating damage in Ringer's solution at 37 °C. The most significant self-healing effect was observed when the ZnMg3.2 wt.% substrate underwent a 1 h immersion in a coating bath containing 2 g of casein, 4 g of NaOH, and 0.1 g of nanoHAp powder. Electrochemical tests were instrumental in determining the optimal casein concentration and immersion time of the Zn alloy in the coating bath.

4.
Biomimetics (Basel) ; 8(5)2023 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-37754159

RESUMO

The structure, phase composition, corrosion and mechanical properties, as well as aspects of biocompatibility in vitro and in vivo, of a Zn-1%Mg-0.1%Dy alloy after equal-channel angular pressing (ECAP) were studied. The structure refinement after ECAP leads to the formation of elongated α-Zn grains with a width of ~10 µm and of Mg- and Dy-containing phases. In addition, X-ray diffraction analysis demonstrated that ECAP resulted in the formation of the basal texture in the alloy. These changes in the microstructure and texture lead to an increase in ultimate tensile strength up to 262 ± 7 MPa and ductility up to 5.7 ± 0.2%. ECAP slows down the degradation process, apparently due to the formation of a more homogeneous microstructure. It was found that the alloy degradation rate in vivo after subcutaneous implantation in mice is significantly lower than in vitro ones. ECAP does not impair biocompatibility in vitro and in vivo of the Zn-1%Mg-0.1%Dy alloy. No signs of suppuration, allergic reactions, the formation of visible seals or skin ulcerations were observed after implantation of the alloy. This may indicate the absence of an acute reaction of the animal body to the Zn-1%Mg-0.1%Dy alloy in both states.

5.
Materials (Basel) ; 16(14)2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37512259

RESUMO

Alloys of magnesium, zinc or iron that do not contain toxic elements are attractive as construction material for biodegradable implants, i.e., the type of implants that harmlessly dissolve away within the human body after they have completed their intended task. The synergistic influence of mechanical stress and corrosive human body fluid can cause sudden and catastrophic fracture of bioimplants due to phenomena such as stress corrosion cracking (SCC) and corrosion fatigue (CF). To date, SCC and CF of implants based on Zn have scarcely been investigated. This article is an overview of the challenges, research needs and way forward in understanding human body-fluid-assisted fractures (i.e., SCC and CF) of Zn alloys in human body fluid.

6.
Materials (Basel) ; 16(8)2023 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-37110036

RESUMO

The use of biodegradable materials for implants is a promising strategy to overcome known long-term clinical complications related to permanent implants. Ideally, biodegradable implants support the damaged tissue for a certain period and then degrade, while the physiological function of the surrounding tissue is restored. Although Mg-based alloys nearly ideally lend themselves to biodegradable implants, a few critical shortcomings promoted the development of alternative alloy systems. Due to their reasonably good biocompatibility, moderate corrosion rate without hydrogen evolution and adequate mechanical properties, increasing attention has been paid to Zn alloys. In this work, precipitation-hardening alloys in the system Zn-Ag-Cu were developed relying on thermodynamic calculations. After casting the alloys, their microstructures were refined by thermomechanical treatment. The processing was tracked and directed, respectively, by routine investigations of the microstructure, associated with hardness assessments. Although microstructure refinement increased the hardness, the material proved to be susceptible to aging as the homologous temperature of zinc is at 0.43 Tm. Besides mechanical performance and corrosion rate, long-term mechanical stability is another crucial factor that must be taken into consideration to ensure the safety of the implant and thus requires a profound understanding of the aging process.

7.
Acta Biomater ; 157: 683-700, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36521674

RESUMO

Infection remains the devastating complications associated with surgical fixation of bones fractured during trauma. In this study, we report a low-alloyed Zn-Mg-Ag that simultaneously has optimized strength degeneration profiles during degradation, outstanding antibacterial efficacy and osteogenic activity. Our results showed that Zn-0.05Mg-0.1Ag alloy had favorable mechanical properties (UTS: 247.8 ± 1.6 MPa, Elong.: 35 ± 2.2 %) and presented a better hold of mechanical integrity than pure Zn during 28 days corrosion, 2.6 % vs. 18.7 % reduction. After one-year of natural aging, the alloy still preserved an elongation of 24.07 ± 3.84 %. As verified by microbial cultures, Zn-0.05Mg-0.1Ag alloy demonstrated high antibacterial performance against Gram-positive and Gram-negative strains, as well as antibiotic-resistant strains (MRSA) in vitro and in vivo due to the synergistic antibacterial actions of Zn2+ and Ag+. Meanwhile, Zn-Mg-Ag alloy also exhibited enhanced viability, osteogenic differentiation, and gene expressions of osteoblasts in vitro, as well as promoted osteogenic activity than pure Zn in the femoral condyle defect repair model. The co-releasing of Zn, Mg and Ag ions did not induce toxic side effects. Collectively, low alloyed Zn-0.05Mg-0.1Ag indicated long-lasting mechanical integrity during degradation, and presented the ability to synergistically inhibit bacteria and promote osteogenesis, possessing tremendous potential in treating implant-associated infections. STATEMENT OF SIGNIFICANCE: Infection after fracture fixation (IAFF) remains the most common and serious side effects of orthopedic surgery. Additionally, widespread antibiotic use contributes to the development of multi-drug resistant bacteria such as methicillin-resistant staphylococcus aureus (MRSA), which exacerbates IAFF treatment and prevention. IAFF treatment and prevention remain clinically challenging, so implants with dual antibacterial and osteogenic functions are in high demand. The antibacterial efficacy and osteogenic activity of low-alloyed Zn-Mg-Ag (≤0.1 wt.% Mg, Ag) alloys were investigated in vitro and in vivo. The results showed that micro addition of Mg and Ag could significantly improve osseointegration function, mechanical properties, and antibacterial performance. These quantification findings shed new light on the development and understanding of dual functional Zn-based orthopedic implants.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Osteogênese , Zinco/farmacologia , Antibacterianos/farmacologia , Ligas/farmacologia , Implantes Absorvíveis , Teste de Materiais
8.
Artigo em Inglês | MEDLINE | ID: mdl-39036610

RESUMO

A new series of zinc alloys is in development for bioresorbable stent implantation to alleviate the current materials' long-term complications. Characterization and optimization of the microstructure and corresponding mechanical properties during manufacturing stages will help researchers meet the required values. In this study, the effect of hot extrusion on the Zn-Ag-Mn-Cu-Zr-Ti alloy is characterized. Additionally, thermal treatments at 390 °C for 15, 25, 40, 60, and 120 min were performed to evaluate the effect of intermetallic phase fractions on the corrosion resistance and mechanical strength. Quantitative analysis of X-ray diffraction data demonstrates that the fractions of the MnZn13, ZrZn22, and Zn0.75Ag0.15Mn0.10 intermetallic phases decrease as the thermal treatment time increases. Corrosion tests reveal a reduction in the corrosion rate of the extruded alloy after thermal treatment. The results of uniaxial compression tests and tensile tests show lower strength and higher ductility in all heat-treated conditions compared with the as-extruded condition.

9.
Materials (Basel) ; 15(24)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36556879

RESUMO

The effect of high-pressure torsion (HPT) on the microstructure, phase composition, mechanical characteristics, degradation rate, and bioactive properties of the Zn-1%Mg alloy is studied. An ultrafine-grained (UFG) structure with an average grain size of α-Zn equal to 890 ± 26 nm and grains and subgrains of the Mg2Zn11 and MgZn2 phases with a size of 50-100 nm are formed after HPT. This UFG structure leads to an increase in the ultimate tensile strength of the alloy by ~3 times with an increase in elongation to 6.3 ± 3.3% due to the formation of a basal texture. The study of corrosion resistance did not show a significant effect of HPT on the degradation rate of the alloy. In addition, no significant changes in the bioactivity of the alloy after HPT: hemolysis, cellular colonization and Escherichia coli growth inhibition.

10.
Ultrason Sonochem ; 89: 106151, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36067645

RESUMO

A refined, equiaxed grain structure and the formation of finer primary intermetallic phases are some of the notable benefits of ultrasonic processing of liquid/solidifying melts. Ultrasonic treatment (UST) has been widely explored in Al and Mg-based alloys due to its operational versatility and scalability. During UST, the refinement of grain and primary intermetallic phases occurs via cavitation-induced fragmentation mechanisms. In addition, UST improves the efficiency (activation of particles) of the conventional grain refinement process when potent particles are added through master alloys. Though the UST's ability to produce refined as-cast structures is well recognized, the understanding of the refinement mechanisms is still debated and unresolved. Significant efforts have been devoted to understanding these mechanisms through the use of sophisticated techniques such as in-situ/ real-time observation, lab-scale and commercial-scale casting processes. All these studies aim to demonstrate the significance of cavitation, fragmentation modes, and alloy chemistry in microstructure refinement. Although the physical effects of cavitation and acoustic streaming (fluid flow) are primary factors influencing the refinement, the dominant grain refinement mechanisms are affected by several solidification variables and casting conditions. Some of these include melt volume, solute, cooling rate, potent particles, grain growth (equiaxed, columnar or dendritic), and the cold zones of the casting where the onset of nucleation occurs. This review aims to provide a better insight into solidification variables emphasizing the importance of cold zones in generating fine structures for small- and large-volume (direct chill) castings. Another important highlight of this review is to present the relatively less explored mechanism of (acoustic) vibration-induced crystallization and discuss the role of cavitation in achieving a refined ingot structure.

11.
ACS Biomater Sci Eng ; 7(12): 5555-5572, 2021 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-34719916

RESUMO

A series of quaternary Zn-Al-Cu-Li alloys with different weight fractions of Cu, Al, and Li were developed and investigated for potential application in high load bearing bioresorbable implants. The developed alloys provided various fractions of binary and ternary intermetallic structures, which resulted in formation of multiphase microstructures containing a zinc-rich η-phase and LiZn4 and CuZn4 phases. The intermetallic phases promoted grain refinement and a good combination of mechanical properties. The developed Zn-2Al-4Cu-0.6Li alloy showed strength and ductility close to commercially pure Ti alloys with a UTS value of ∼535 MPa and elongation of 37%. The examination of in vitro corrosion behavior of the developed alloys in the modified Hanks' solution revealed suitable corrosion rates (∼38.5 µm/year). The moderate corrosion rate was controlled by the formation of a homogeneous layer of stable corrosion products that protected the alloys from the corrosive environment, particularly in the late stages of immersion. The developed alloys with the most promising mechanical and corrosion properties appeared to be biocompatible to mouse fibroblast cells and human umbilical mesenchymal stem cells, making them suitable candidates for implant applications.


Assuntos
Ligas , Zinco , Animais , Corrosão , Teste de Materiais , Camundongos , Resistência à Tração
12.
Bioact Mater ; 6(12): 4430-4446, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34027233

RESUMO

In the recent decades, zinc (Zn) and its alloys have been drawing attention as promising candidates for bioresorbable cardiovascular stents due to its degradation rate more suitable than magnesium (Mg) and iron (Fe) alloys. However, its mechanical properties need to be improved in order to meet the criteria for vascular stents. This work investigates the mechanical properties, biodegradability and biocompatibility of Zn-Mg and Zn-Cu alloys in order to determine a proper alloy composition for optimal stent performance. Nanoindentation measurements are performed to characterize the mechanical properties at the nanoscale as a function of the Zn microstructure variations induced by alloying. The biodegradation mechanisms are discussed and correlated to microstructure, mechanical performance and bacterial/cell response. Addition of Mg or Cu alloying elements refined the microstructure of Zn and enhanced yield strength (YS) and ultimate tensile strength (UTS) proportional to the volume fraction of secondary phases. Zn-1Mg showed the higher YS and UTS and better performance in terms of degradation stability in Hanks' solution. Zn-Cu alloys presented an antibacterial effect for S. aureus controlled by diffusion mechanisms and by contact. Biocompatibility was dependent on the degradation rate and the nature of the corrosion products.

13.
Bioact Mater ; 6(10): 3424-3436, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33817418

RESUMO

In recent years, Zn-based materials have been extensively investigated as potential candidates for biodegradable implant applications. The introduction of alloying elements providing solid-solution strengthening and second phase strengthening seems crucial to provide a suitable platform for the thermo-mechanical strengthening of Zn alloys. In this study, a systematic investigation of the microstructure, crystallographic texture, phase composition, and mechanical properties of a Zn-3Ag-0.5Mg (wt%) alloy processed through combined hot extrusion (HE) and cold rolling (CR), followed by short-time heat treatment (CR + HT) at 200 °C was conducted. Besides, the influence of different annealing temperatures on the microstructure and mechanical properties was studied. An adequate combination of processing conditions during CR and HT successfully addressed brittleness obtained in the high-strength HE Zn-3Ag-0.5Mg alloy. By controlling the microstructure, the most promising results were obtained in the sample subjected to 50% CR reduction and 5-min annealing, which were: ultimate tensile strength of 432 MPa, yield strength of 385 MPa, total elongation to failure of 34%, and Vickers microhardness of 125 HV0.3. The obtained properties clearly exceed the mechanical benchmarks for biodegradable implant materials. Based on the conducted investigation, brittle multi-phase Zn alloys' mechanical performance can be substantially enhanced to provide sufficient plasticity by grain refinement through cold deformation process, followed by short-time annealing to restore proper strength.

14.
Mater Sci Eng C Mater Biol Appl ; 122: 111897, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33641900

RESUMO

A series of Zn-Al-Li alloys with potential application in bioresorbable implants were cast, thermomechanically processed and tested. The formation of secondary phases, such as LiZn4, LiZn3Al and Al3Li, contributed to both dynamic recrystallization and grain refinement of the matrix (η-phase) during the hot-extrusion process, leading to grain sizes as small as 1.75 µm for Zn-4Al-0.6Li alloy (wt%). This alloy exhibited an ultimate tensile strength (UTS) of 451 MPa, a total elongation of 46% and a corrosion rate of 60 µm/year in simulated body fluid. The grain refinement played a major role in increasing the strength, but it also weakened the basal texture and promoted non-basal slip and grain boundary sliding, thus contributing to the increased plastic deformation of the alloy. The corrosion rate was affected by a layer of zinc oxide and phosphate formed in the early stages of the immersion tests. The corrosion products protected the substrate and tended to reduce the corrosion rate over time. The developed Zn-4Al-0.6Li and Zn-6Al-0.4Li alloys which showed promising mechanical and corrosion properties appeared to be cytocompatible in the mouse fibroblast cell line and human umbilical mesenchymal stem cells making them promising candidates for bioresorbable stent and implant applications.


Assuntos
Implantes Absorvíveis , Ligas , Animais , Corrosão , Teste de Materiais , Camundongos , Resistência à Tração , Zinco
15.
J Biomed Mater Res B Appl Biomater ; 108(7): 2925-2936, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32662233

RESUMO

Zn alloys are emerging as promising degradable biomedical materials due to their tailorable mechanical properties and moderate biodegradable rate, compared with conventional biodegradable metallic materials. Ag, as an effective antibacterial and reinforcing element, was incorporated into Zn-0.05Mg alloys. In the present work, the effects of the Ag addition on mechanical, cytotoxic, hemolytic, pyrogenic, histological behaviors of the animal were investigated. The compressive yielding strength is enhanced from 198 MPa for Zn-0.05Mg alloy up to 224 and 234 MPa for Zn-0.05Mg-0.5Ag and Zn-0.05Mg-1Ag alloys, respectively. When the compressive strain was 65%, the strength of the Zn-0.05Mg-1.0Ag alloy reached 833 MPa, which was much higher than that of 721 MPa for Zn-0.05Mg alloy. The relative growth rate (RGR) for the extracts of Zn-0.05Mg-1Ag alloy with the concentrations of 10, 50, and 100% after 5 days incubation reaches 98.5, 95.2, and 94.2%, which are higher than those in extracts of Zn-0.05Mg-0.5Ag alloy (98.2, 93.9, 92.1%). The hemolysis rate of the Zn-0.05Mg alloys with 0.5 and 1 wt% Ag is 2.46 and 2.28%, respectively. The variations of body weight and temperature, postinjection symptoms, pathological morphologies of the visceral organs demonstrate that the alloys are nontoxic according to the toxicity rating standards. Zn-0.05wt%Mg-(0.5, 1 wt%) Ag alloys are experimentally safe materials and promising for the future application as biodegradable medical devices.


Assuntos
Ligas , Materiais Biocompatíveis , Magnésio , Teste de Materiais , Prata , Ligas/química , Ligas/farmacologia , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Linhagem Celular , Magnésio/química , Magnésio/farmacologia , Camundongos , Coelhos , Prata/química , Prata/farmacologia
16.
J Mech Behav Biomed Mater ; 108: 103796, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32469720

RESUMO

The Zn-based alloys, alloyed with the elements of the 2nd group of the periodic table, are considered as potential biodegradable materials suitable for the fabrication of small orthopaedic implants or cardiovascular stents. Unfortunately, the as-cast Zn-based alloys do not fulfil the requirements for mechanical properties for such applications. Extrusion is a thermomechanical process which is very powerful for breaking the cast microstructure and enhancing mechanical characteristics of metallic materials. In this study, we focused on the influence of extrusion parameters, such as temperature and extrusion ratio, on microstructural and mechanical characteristics of a ZnMg0.8Ca0.2 (wt.%) alloy. The extrusion led to a significant grain refinement and the formation of a crystallographic texture. Extrusion temperature played a more significant role in the mean grain size compared to the extrusion ratio (ER). At lower extrusion temperatures, the texture was less intensive and the subsequent mechanical anisotropy was weaker. Constants for the prediction of the grain size based on the Zener-Hollomon parameter were obtained. Prediction of mechanical properties using the Hall-Petch relationship appeared to be difficult because of the dependence of the texture on the extrusion temperature. Extrusion at the temperatures of 200 °C (ER = 25:1) and 150 °C (ER = 11:1) led to mechanical performance fulfilling the requirements for implantology.


Assuntos
Ligas , Materiais Biocompatíveis , Corrosão , Stents , Temperatura
17.
Materials (Basel) ; 13(7)2020 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-32260551

RESUMO

The main purpose of this work was to experimentally determine the effect of the cooling rate during the eutectoid transformation on the corrosion resistance of a hypoeutectic Zn-4Al cast alloy in 5% NaCl solution. This was considered in relation to the alloy microstructure. For this purpose, metallographic and electrochemical studies were performed. It was found that the faster cooling promoted the formation of finer (α + η) eutectoid structures, which translated into a higher hardness and lower corrosion current density. In the initial stage of corrosion processes the eutectoid structure in the eutectic areas were attacked. At the further stages of corrosion development, the phase η was dissolved, and the α phase appears to be protected by the formation of corrosion products.

18.
Acta Biomater ; 105: 319-335, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-31982587

RESUMO

Zn-based alloys are recognized as promising bioabsorbable materials for cardiovascular stents, due to their biocompatibility and favorable degradability as compared to Mg. However, both low strength and intrinsic mechanical instability arising from a strong strain rate sensitivity and strain softening behavior make development of Zn alloys challenging for stent applications. In this study, we developed binary Zn-4.0Ag and ternary Zn-4.0Ag-xMn (where x = 0.2-0.6wt%) alloys. An experimental methodology was designed by cold working followed by a thermal treatment on extruded alloys, through which the effects of the grain size and precipitates could be thoroughly investigated. Microstructural observations revealed a significant grain refinement during wire drawing, leading to an ultrafine-grained (UFG) structure with a size of 700 nm and 200 nm for the Zn-4.0Ag and Zn-4.0Ag-0.6Mn, respectively. Mn showed a powerful grain refining effect, as it promoted the dynamic recrystallization. Furthermore, cold working resulted in dynamic precipitation of AgZn3 particles, distributing throughout the Zn matrix. Such precipitates triggered mechanical degradation through an activation of Zn/AgZn3 boundary sliding, reducing the tensile strength by 74% and 57% for Zn-4.0Ag and Zn-4.0Ag-0.6Mn, respectively. The observed precipitation softening caused a strong strain rate sensitivity in cold drawn alloys. Short-time annealing significantly mitigated the mechanical instability by reducing the AgZn3 fraction. The ternary alloy wire showed superior microstructural stability relative to its Mn-free counterpart due to the pinning effect of Mn-rich particles on the grain boundaries. Eventually, a shift of the corrosion regime from localized to more uniform was observed after the heat treatment, mainly due to the dissolution of AgZn3 precipitates. STATEMENT OF SIGNIFICANCE: Owing to its promising biodegradability, zinc has been recognized as a potential biodegradable material for stenting applications. However, Zn's poor strength alongside intrinsic mechanical instability have propelled researchers to search for Zn alloys with improved mechanical properties. Although extensive researches have been conducted to satisfy the mentioned concerns, no Zn-based alloys with stabilized mechanical properties have yet been reported. In this work, the mechanical properties and stability of the Zn-Ag-based alloys were systematically evaluated as a function of microstructural features. We found that the microstructure design in Zn alloys can be used to find an effective strategy to not only improve the strength and suppress the mechanical instability but also to minimize any damage by augmenting the corrosion uniformity.


Assuntos
Implantes Absorvíveis , Ligas/química , Vasos Sanguíneos/patologia , Stents , Zinco/química , Corrosão , Teste de Materiais , Soluções , Estresse Mecânico , Resistência à Tração , Difração de Raios X
19.
Materials (Basel) ; 12(19)2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31547174

RESUMO

Unlike other HCP metals such as titanium and magnesium, the behavior of zinc alloys has only been modeled in the literature. For the low Zn-Cu-Ti alloy sheet studied in this work, the anisotropy is clearly seen on the stress-strain curves and Lankford coefficients. These features impose a rigorous characterization and an adequate selection of the constitutive model to obtain an accurate representation of the material behavior in metal forming simulations. To describe the elastoplastic behavior of the alloy, this paper focuses on the material characterization through the application of the advanced Cazacu-Plunket-Barlat 2006 (CPB-06 for short) yield function combined with the well-known Hollomon hardening law. To this end, a two-stage methodology is proposed. Firstly, the material characterization is performed via tensile test measurements on sheet samples cut along the rolling, diagonal and transverse directions in order to fit the parameters involved in the associate CPB-06/Hollomon constitutive model. Secondly, these material parameters are assessed and validated in the simulation of the bulge test using different dies. The results obtained with the CPB-06/Hollomon model show a good agreement with the experimental data reported in the literature. Therefore, it is concluded that this model represents a consistent approach to estimate the behavior of Zn-Cu-Ti sheets under different forming conditions.

20.
Adv Sci (Weinh) ; 6(14): 1900112, 2019 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-31380203

RESUMO

Recently emerged metallic zinc (Zn) is a new generation of promising candidates for bioresorbable medical implants thanks to its essential physiological relevance, mechanical strength, and more matched degradation pace to that of tissue healing. Zn-based metals exhibit excellent biocompatibility in various animal models. However, direct culture of cells on Zn metals yields surprisingly low viability, indicating high cytotoxicity of Zn. This contradicting phenomenon should result from the different degradation mechanisms between in vitro and in vivo. To solve this puzzle, the roles of all major players, i.e., zinc phosphate (ZnP), zinc oxide (ZnO), zinc hydroxide (Zn(OH)2), pH, and Zn2+, which are involved in the degradation process are examined. Data shows that ZnP, not ZnO or Zn(OH)2, significantly enhances its biocompatibility. The mild pH change during degradation also has no significant impact on cell viability. Collectively, ZnP appears to be the key to controlling the biocompatibility of Zn implants and could be applied as a novel surface coating to improve biocompatibility of different implants.

SELEÇÃO DE REFERÊNCIAS