Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 685
Filtrar
1.
Int Ophthalmol ; 44(1): 292, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940969

RESUMO

PURPOSE: Compared to Shack-Hartmann wavefront sensor (SHWS), the parameters of virtual SHWS (vSHWS) can be easily adjusted to obtain the optimal performance of aberration measurement. Its current optimal parameters are obtained with only a set of statistical aberrations and not statistically significant. Whether the above parameters are consistent with the statistical results of the optimal parameters corresponding to each set of aberrations, and which performance is better if not? The purpose of this study was to answer these questions. METHODS: The optimal parameters to reconstruct 624 sets of clinical ocular aberrations in the highest accuracy, including the numbers of sub-apertures (NSAs) and the expansion ratios (ERs) of electric field zero-padding, were determined sequentially in this work. By using wavefront-reconstruction accuracy as an evaluation index, the statistical optimal parameter configuration was selected from some possible configurations determined by the optimal NSAs and ERs. RESULTS: The statistical optimal parameters are consistent for normal and abnormal eyes. They are different from the optimal parameters obtained with a set of statistical aberrations from the same 624 sets of aberrations, and the performance using the former is better than that using the latter. The performance using a fixed set of statistical optimal parameters is even close to that using the respective optimal parameters corresponding to each set of aberrations. CONCLUSION: The vSHWS configured with a fixed set of statistical optimal parameters can be used for high-precision aberration measurement of both normal and abnormal eyes. The statistical optimal parameters are more suitable for vSHWS than the parameters obtained with a set of statistical aberrations. These conclusions are significant for the designs of vSHWS and also SHWS.


Assuntos
Aberrações de Frente de Onda da Córnea , Humanos , Aberrações de Frente de Onda da Córnea/diagnóstico , Aberrações de Frente de Onda da Córnea/fisiopatologia , Topografia da Córnea/métodos , Aberrometria/métodos , Refração Ocular/fisiologia , Acuidade Visual/fisiologia
2.
Sensors (Basel) ; 24(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38931650

RESUMO

The objective of this study was to assess the effect of sustained reading on the temporal changes in the wavefront error in the presbyopic eye. The wavefront aberration of the eyes was measured using an IRX3 Shack-Hartmann aberrometer before and after (immediately, 5 min, and 10 min after) a reading task. Temporal changes in C20, C40, and C3-1 coefficient values of the eyes were plotted, showing a predominant number of V-shaped patterns (for C40 and C3-1) and inverse V-shaped patterns (for C20) among the study group, and the percentages (between 27 and 73%) were reported. The median of the total RMS of aberrations and the RMS of HOA (higher-order aberrations), which included comatic (3rd order) and spherical-like aberrations (4th and 6th order), increased immediately after finishing the near-vision reading task and then decreased. The median of RMS of comatic aberrations had a similar pattern of variations, while the median of RMS of spherical-like aberrations displayed an opposite pattern. Simulating the aberration changes due to lens decentration caused by relaxed zonules during 4 D accommodation in an eye model demonstrated that the expected range of changes for the vertical coma and spherical aberrations are in the order of 0.001 and 0.01 µm, respectively, which could justify why the observed changes were not statistically significant. The observed dynamic changes in HOA might be linked to the biomechanical characteristics and alterations in the displacement of the crystalline lens following prolonged near-vision tasks in presbyopic people. Although some predominant patterns under some conditions were shown, they exhibit considerable inter-subject and inter-ocular variability. This might be due to slight misalignments while fixating on the internal extended object in the aberrometer.


Assuntos
Presbiopia , Leitura , Humanos , Presbiopia/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Aberrometria , Acomodação Ocular/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Idoso
3.
Sci Rep ; 14(1): 9984, 2024 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693352

RESUMO

The aim of this work is to quantitatively assess the wavefront phase of keratoconic eyes measured by the ocular aberrometer t·eyede (based on WaveFront Phase Imaging Sensor), characterized by a lateral resolution of 8.6 µm without requiring any optical element to sample the wavefront information. We evaluated the parameters: root mean square error, Peak-to-Valley, and amplitude of the predominant frequency (Fourier Transform analysis) of a section of the High-Pass filter map in keratoconic and healthy cohorts. Furthermore, we have analyzed keratoconic eyes that presented dark-light bands in this map to assess their period and orientation with the Fourier Transform. There are significant statistical differences (p value < 0.001) between healthy and keratoconic eyes in the three parameters, demonstrating a tendency to increase with the severity of the disease. Otherwise, the quantification of the bands reveals that the width is independent of eye laterality and keratoconic stage as orientation, which tends to be oblique. In conclusion, the quantitative results obtained with t·eyede could help to diagnose and monitor the progression of keratoconus.


Assuntos
Ceratocone , Ceratocone/diagnóstico por imagem , Ceratocone/diagnóstico , Humanos , Adulto , Feminino , Masculino , Topografia da Córnea/métodos , Adulto Jovem , Aberrometria/métodos , Córnea/diagnóstico por imagem , Córnea/patologia , Análise de Fourier
4.
Vestn Oftalmol ; 140(2): 48-53, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38742498

RESUMO

Purpose. The study investigates corneal and higher-order internal aberrations in patients with amblyopia of different etiologies and their relationship with visual acuity, refraction, axial length, and fixation parameters. MATERIAL AND METHODS: Forty-five patients (90 eyes) were examined. All patients were divided into five groups: 1 - with dysbinocular amblyopia; 2 - with refractive amblyopia; 3 - with anisometropic amblyopia; 4 - with relative amblyopia due to congenital myopia; 5 (control) - fellow eyes without amblyopia. Aberrometry was performed using the OPD-Scan III device (Nidek, Japan). Fixation parameters were studied on the MP-3 microperimeter (Nidek, Japan). Correlation analysis was performed using Pearson's linear correlation coefficient (r). RESULTS: In amblyopia associated with congenital myopia, a significant increase in corneal and internal aberrations RMS, Total HOA, astigmatism (V) (0.65±0.26; 1.01±0.31; 4.22±1.17; -2.17±0.72; 0.86±0.3, respectively; control group - 0.44±0.19; 0.58±0.27; 1.0±0.75; -0.94±0.89; 0.47±0.65) and internal spherical aberration (0.06±0.02; control group - 0.04±0.03) was found. In dysbinocular amblyopia, a significant increase in internal aberrations Trefoil (V) and Coma (H) (0.75±0.52 and 0.17±0.35, respectively; control group - 0.05±0.28 and -0.07±0.21) was found, which correlated with a decrease in fixation density in the 2° ring (r= -0.40, r= -0.41). CONCLUSIONS: The increased level of higher-order aberrations in amblyopia associated with congenital myopia is due to the anatomical and optical features of the eyes. The increase in internal aberrations Trefoil (V) and Coma (H) in dysbinocular amblyopia is associated with a mismatch of the optical elements of the eye due to impaired fixation, i.e., it is not the cause, but the consequence of amblyopia.


Assuntos
Ambliopia , Miopia , Acuidade Visual , Humanos , Ambliopia/etiologia , Ambliopia/fisiopatologia , Ambliopia/diagnóstico , Masculino , Criança , Feminino , Miopia/complicações , Miopia/fisiopatologia , Miopia/diagnóstico , Refração Ocular/fisiologia , Aberrometria/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/etiologia , Aberrações de Frente de Onda da Córnea/diagnóstico
5.
J Refract Surg ; 40(5): e291-e303, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38717083

RESUMO

PURPOSE: To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS: In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS: For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS: SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].


Assuntos
Aberrometria , Astigmatismo , Córnea , Substância Própria , Aberrações de Frente de Onda da Córnea , Densitometria , Ceratomileuse Assistida por Excimer Laser In Situ , Lasers de Excimer , Miopia , Refração Ocular , Acuidade Visual , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Aberrações de Frente de Onda da Córnea/fisiopatologia , Estudos Prospectivos , Miopia/cirurgia , Miopia/fisiopatologia , Adulto , Feminino , Masculino , Lasers de Excimer/uso terapêutico , Acuidade Visual/fisiologia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiopatologia , Adulto Jovem , Refração Ocular/fisiologia , Astigmatismo/cirurgia , Astigmatismo/fisiopatologia , Cirurgia da Córnea a Laser/métodos , Topografia da Córnea
6.
J Cataract Refract Surg ; 50(7): 739-745, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38480607

RESUMO

PURPOSE: To evaluate the intrasubject repeatability of pyramidal aberrometer measurements in a sample of keratoconus and normal eyes. SETTING: American University of Beirut Medical Center, Beirut, Lebanon. DESIGN: Prospective comparative repeatability analysis. METHODS: Study population: Keratoconus and normal eyes from adult patients. Observation procedures: Each eye was evaluated with 3 consecutive acquisitions using a pyramidal aberrometer. Main outcome measures: The repeatability of different ocular higher-order aberrations and lower-order aberrations (HOAs and LOAs, respectively), and Zernike coefficients down to the fifth order, was evaluated. Repeatability was assessed by within-subject SDs (Sw), repeatability limits ( r ), and intraclass correlation coefficients (ICCs), among other parameters. RESULTS: 72 keratoconus patients (72 eyes) and 76 normal patients (76 eyes) were included. In normal and keratoconus eyes, the ICC of total LOAs and HOAs, as well as each of the Zernike coefficients, was >0.9. The Sw for keratoconus eyes with mean maximal keratometry (Kmax) <50 diopters (D) was 0.1345 for total LOAs, 0.0619 for total HOAs, 0.0292 for horizontal coma, 0.0561 for vertical coma, and 0.0221 for spherical aberration as compared with 0.2696, 0.1486, 0.0972, 0.1497, and 0.0757 for keratoconus eyes with Kmax ≥50 D. Similar trend of better repeatability for grade 1 keratoconus and HOAs <2 D as compared with grades 2 and 3 keratoconus and eyes with HOAs >2 D were also noted. CONCLUSIONS: Ocular aberrometer measurements generated by high definition pyramidal aberrometers have high repeatability in both normal and mild keratoconus eyes and moderate repeatability, yet still clinically acceptable, in advanced keratoconus. This is of particular importance in ocular wavefront-guided treatments.


Assuntos
Aberrometria , Topografia da Córnea , Aberrações de Frente de Onda da Córnea , Ceratocone , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Feminino , Masculino , Topografia da Córnea/métodos , Adulto Jovem , Pessoa de Meia-Idade , Córnea/patologia , Voluntários Saudáveis , Acuidade Visual/fisiologia , Adolescente
7.
J Cataract Refract Surg ; 50(6): 585-590, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350145

RESUMO

PURPOSE: To evaluate visual and refractive outcomes, as well as patient satisfaction after bilateral implantation of an enhanced monofocal intraocular lens (IOL) with emmetropia as a target refraction. SETTING: San Carlos Hospital, Madrid, Spain. DESIGN: Prospective, monocentric, noncomparative study. METHODS: Adults 21 years or older suitable for cataract surgery and with corneal astigmatism <1.50 diopters (D) were bilaterally implanted with the RayOne EMV IOL and followed up for 3 months. Outcomes measures included refraction, monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity, distance-corrected intermediate visual acuity (DCIVA), and defocus curve, aberrometry, and satisfaction. Visual symptoms were assessed using the CatQuest-9SF questionnaire. RESULTS: 50 eyes of 25 patients were included. At month 3, the mean manifest spherical equivalent was -0.39 ± 0.28 D, with all eyes within 1.00 D. Binocularly, uncorrected, at distance, 68% of patients could read ≤0.0 logMAR and 95% ≤0.2 logMAR; at intermediate 59% of patients could read ≤0.1 and 100% ≤0.2 logMAR. Mean monocular CDVA was -0.03 ± 0.06 logMAR and mean monocular DCIVA was 0.28 ± 0.07 logMAR. Binocular defocus curve demonstrated a visual acuity ≤0.2 logMAR over a 2 D range from +1.00 D to -1.25 D. Satisfaction was good in 96% of patients. CONCLUSIONS: Bilateral implantation of an enhanced monofocal IOL with emmetropia as a target provided excellent binocular CDVA and good DCIVA, with a high level of satisfaction.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Satisfação do Paciente , Facoemulsificação , Pseudofacia , Refração Ocular , Visão Binocular , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Pseudofacia/fisiopatologia , Masculino , Feminino , Visão Binocular/fisiologia , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários , Desenho de Prótese , Adulto , Emetropia/fisiologia , Aberrometria
8.
J Cataract Refract Surg ; 50(6): 631-636, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38407983

RESUMO

PURPOSE: To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX. SETTING: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. DESIGN: Prospective, comparative trial. METHODS: Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed. RESULTS: 36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard ( P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different ( P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux. CONCLUSIONS: Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.


Assuntos
Interferometria , Pupila , Humanos , Pupila/fisiologia , Estudos Prospectivos , Adulto , Pessoa de Meia-Idade , Masculino , Feminino , Adulto Jovem , Reprodutibilidade dos Testes , Interferometria/instrumentação , Aberrometria/instrumentação , Iris , Raios Infravermelhos , Técnicas de Diagnóstico Oftalmológico/instrumentação , Ofuscação
9.
Indian J Ophthalmol ; 72(7): 1037-1042, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38324626

RESUMO

PURPOSE: To investigate the impact of scleral lenses (SLs) on higher-order aberrations (HOAs), corrected distance visual acuity (CDVA), and contrast sensitivity (CS) in pellucid marginal degeneration (PMD) eyes. METHODS: SLs were fitted in 24 eyes diagnosed with PMD. CDVA, CS, and HOAs were measured at baseline and with the lens on the eye. The HOAs were measured using an i-Trace aberrometer. RESULTS: A statistically significant improvement was noted in CDVA ( P < 0.001) with BSS lenses (0.05 ± 0.04) compared to baseline (0.42 ± 0.06). Front surface eccentricity 1 (FSE1) lens provided the best CDVA in most of the eyes. The baseline CS of 1.24 ± 0.74 improved to 1.58 ± 0.48 with SL and reported a statistically significant improvement ( P < 0.001) and a gain of 6 letters. The baseline higher order-root mean square (HO-RMS) was 0.89 ± 0.53 µm, which reduced to 0.38 ± 0.24 µm ( P < 0.001), and RMS coma of 0.45 ± 0.29 µm improved to 0.20 ± 0.12 µm ( P < 0.001). Though there was a marginal reduction from 0.04 ± 0.14 to 0.03 ± 0.07, RMS spherical aberration did not show any statistically significant difference ( P = 0.37). RMS secondary astigmatism reduced from 0.17 ± 0.15 µm to 0.08 ± 0.12 µm ( P = 0.007), and RMS trefoil reduced to 0.13 ± 0.09 µm from 0.64 ± 0.36 µm ( P < 0.001) with SLs and showed statistically significant improvement. CONCLUSION: SLs can be considered an effective option that corrects a significant amount of HOAs and enhances visual performances in PMD eyes.


Assuntos
Topografia da Córnea , Aberrações de Frente de Onda da Córnea , Refração Ocular , Esclera , Acuidade Visual , Humanos , Feminino , Acuidade Visual/fisiologia , Masculino , Adulto , Aberrações de Frente de Onda da Córnea/fisiopatologia , Aberrações de Frente de Onda da Córnea/diagnóstico , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Seguimentos , Lentes de Contato , Sensibilidades de Contraste/fisiologia , Adulto Jovem , Distrofias Hereditárias da Córnea/fisiopatologia , Distrofias Hereditárias da Córnea/diagnóstico , Aberrometria , Estudos Prospectivos , Córnea/patologia , Córnea/diagnóstico por imagem
10.
Photodiagnosis Photodyn Ther ; 45: 103876, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37923283

RESUMO

PURPOSE: To compare the consistency of Pentacam Scheimpflug system (Pentacam® HR), ray-tracing aberrometry (iTrace), and swept source optical coherence tomography (IOLMaster 700) measurements for Angle Kappa and angle Alpha. METHODS: A prospective randomized cohort study. 86 individuals (86 eyes) aged 19-45 years with best corrected vision of 4.9 or better were randomly selected from January 2022 to December 2022 in a tertiary-level hospital. Angle Kappa and angle Alpha were measured or calculated using Pentacam, iTrace, and IOLMaster 700, respectively. RESULTS: The mean difference of angle Kappa between any two instruments was not statistically significant, but the mean difference of angle Alpha between both Pentacam and iTrace, Pentacam and IOLMaster 700, and iTrace and IOLMaster 700 was statistically significant (p value <0.001, 0.003, <0.001). The highest consistency of angle Kappa and the narrowest 95% LoA (-0.20 to 0.21) were found between Pentacam and iTrace according to Bland Altman plots, but between Pentacam and IOLMaster 700 according to Mountain plots. Both Bland Altman plots and Mountain plots showed the highest consistency of angle Alpha and the narrowest 95% LoA (-0.14 to 0.24) between Pentacam and iTrace. CONCLUSION: The mean angle Kappa among Pentacam® HR, iTrace, and IOLMaster 700 had good agreement, and the value of angle Kappa could be output directly, making it more convenient for clinical application. The measured or calculated angle Alpha had poor agreement, and ophthalmologists could refer to measurements from multiple instruments.


Assuntos
Córnea , Fotoquimioterapia , Humanos , Aberrometria , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Estudos de Coortes , Reprodutibilidade dos Testes , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes
11.
Rev. cuba. oftalmol ; 36(3)sept. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550935

RESUMO

Objetivo: Determinar parámetros aberrométricos de la córnea para la detección del queratocono subclínico. Métodos: Se realizó un estudio observacional, analítico de corte transversal que incluyó 36 pacientes con queratocono subclínico (grupo de estudio) y 36 estudiantes con córneas aparentemente sanas (grupo control), que asistieron a la consulta de córnea del Instituto Cubano de Oftalmología Ramón Pando Ferrer, entre mayo de 2018 y junio de 2022. Se analizaron topografía y aberrometría corneal con el tomógrafo corneal Pentacam AXL. Resultados: El grupo queratocono subclínico mostró valores similares para la queratometría, asfericidad corneal, paquimetría y el valor total de desviación en comparación con el grupo normal. Hubo diferencias estadísticamente significativas en los parámetros aberrométricos, como el coma a 90º (Z3 -1), y la raíz cuadrada media de las aberraciones de alto orden, de cara anterior, posterior y total corneal, en queratocono subclínico en comparación con el grupo normal. El coma posterior a 90º presentó un área bajo la curva (0,894) mayor dentro de las aberrometrías, con un punto de corte de -0,013 µm, con sensibilidad del 86,1 por ciento y especificidad del 88,9 por ciento. Conclusiones: El coma posterior a 90º (parámetro aberrométrico) presenta una alta sensibilidad y especificidad para el diagnóstico de queratocono subclínico, mediante el análisis tomográfico Pentacam AXL(AU)


Objective: To determine corneal aberrometric parameters for the detection of subclinical keratoconus. Methods: An observational, analytical, cross-sectional study was performed including 36 patients with subclinical keratoconus (study group) and 36 students with apparently healthy corneas (control group), who attended the cornea consultation at the Cuban Institute of Ophthalmology Ramón Pando Ferrer, between May 2018 and June 2022. Corneal topography and aberrometry were analyzed with the Pentacam AXL corneal tomographer. Results: The subclinical keratoconus group showed similar values for keratometry, corneal asphericity, pachymetry and total deviation value compared to the normal group. There were statistically significant differences in aberrometric parameters, such as coma at 90° (Z3-1), and root mean square of high-order anterior, posterior and total corneal aberrations in subclinical keratoconus compared to the normal group. The 90° posterior coma presented a higher area under the curve (0.894) within the aberrometries, with a cutoff point of -0.013 µm, with sensitivity of 86.1 percent and specificity of 88.9 percent. Conclusions: Coma posterior to 90º (aberrometric parameter) presents high sensitivity and specificity for the diagnosis of subclinical keratoconus, using Pentacam AXL tomographic analysis(AU)


Assuntos
Humanos , Feminino , Córnea/anormalidades , Aberrometria/métodos , Ceratocone/etiologia , Estudos Observacionais como Assunto
12.
Indian J Ophthalmol ; 71(8): 2978-2983, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37530268

RESUMO

Purpose: To compare the slit-lamp method and wavefront aberrometry method based on outcomes of toric realignment surgeries. Settings: Tertiary care ophthalmic hospital. Design: Retrospective study. Methods: This study included all eyes undergoing toric intraocular lens (TIOL) realignment surgery between January 2019 and December 2021 for which TIOL axis assessment by slit-lamp method and wavefront aberrometry method was available. Data were retrieved from electronic medical records, and we documented demographics, uncorrected visual acuity (UCVA), subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods on postoperative day 1 and day 14. In patients with misalignment, TIOL was realigned to the original position in group 1 (27 patients) and to an axis based on calculations provided by wavefront aberrometer in group 2 (25 patients). Post-realignment surgery, UCVA, subjective refraction, and TIOL axis by slit-lamp and wavefront aberrometry methods were assessed and analyzed. Results: We analyzed 52 eyes and found that the mean preoperative misalignment with the slit-lamp method (44.9° ±20.0°) and wavefront aberrometry (47.1° ±19.5°) was similar. The corresponding degrees of misalignment post-TIOL repositioning surgeries were 5.2° ±5.2° (slit-lamp method) and 4.7° ±5.1° (wavefront aberrometry) (P = 0.615). Both groups showed significant improvement in median log of minimum angle of resolution (logMAR) UCVA and reduction in median refractive cylinder. Conclusions: Slit-lamp method is as good as wavefront aberrometer method to assess TIOL axis. Toric realignment surgery is found to be safe, and realigning TIOL based on either slit-lamp method or wavefront aberrometer method equally improved UCVA and decreased residual refractive cylinder.


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Aberrometria , Estudos Retrospectivos , Facoemulsificação/métodos , Astigmatismo/diagnóstico , Astigmatismo/cirurgia , Estudos Prospectivos , Refração Ocular , Córnea
13.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2863-2872, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37171601

RESUMO

PURPOSE: To evaluate and compare the objective refractions obtained by autorefraction and aberrometry under different lighting conditions with an isofocal intraocular lens (Isopure, BVI medical, Liége, Belgium) compared to a monofocal control lens (Micropure, BVI medical, Liége, Belgium) with the same platform and material. METHODS: Prospective, comparative and randomized study on patients undergoing cataract surgery and bilateral isofocal or monofocal IOL implantation. A total of 44 subjects were randomly assigned to either the isofocal group (n = 22) or the Micropure (n = 22). Manifest refraction (MR) was always performed under the same lighting conditions for all the patients. For objective refraction the autorefractor KR8800 and the aberrometer OPD-Scan III (Nidek Inc., Tokyo, Japan.) were used. For each eye included in the study, six result sets were collected: MR, AR (autorefraction measured with the autorefractor), WF-P and WF-M (Zernike-coefficients-based objective refraction, photopic and mesopic pupil size), OPD-C and OPD-M (autorefraction measured with the aberrometer in photopic and mesopic conditions). RESULTS: The mean sphere for MR was 0.03 ± 0.32D for the Isopure group and 0.24 ± 0.22D for the monofocal group (p = 0.013). For the Isopure group, Friedman analysis showed statistically significant differences for sphere measured with WF-P (p = 0.035), WF-M (p = 0.018) and OPD-M (p = 0.000), and SE measured with OPD-M (p = 0.004). In the Micropure lens group, the Friedman analysis showed differences for all values studied (p < 0.05). Correlation coefficients showed that AR is the objective method with the strongest correlation values for all components of refraction for both groups. CONCLUSION: The modification of the surfaces of the isofocal lens does not have a negative impact on the refraction obtained by AR compared to a standard monofocal intraocular lens.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Aberrometria , Acuidade Visual , Implante de Lente Intraocular , Estudos Prospectivos , Facoemulsificação/métodos , Refração Ocular
14.
Indian J Ophthalmol ; 71(5): 1918-1923, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37203056

RESUMO

Purpose: Barrett toric calculator (BTC) is known for its accuracy in toric IOL (tIOL) calculation over standard calculators; however, there is no study in literature to compare it with real-time intraoperative aberrometry (IA). The aim was to compare the accuracy of BTC and IA in predicting refractive outcomes in tIOL implantation. Methods: This was an institution-based prospective, observational study. Patients undergoing routine phacoemulsification with tIOL implantation were enrolled. Biometry was obtained from Lenstar-LS 900 and IOL power calculated using online BTC; however, IOL was implanted as per IA (Optiwave Refractive Analysis, ORA, Alcon) recommendation. Postoperative refractive astigmatism (RA) and spherical equivalent (SE) were recorded at one month, and respective prediction errors (PEs) were calculated using predicted refractive outcomes for both methods. The primary outcome measure was a comparison between mean PE with IA and BTC, and secondary outcome measures were uncorrected distance visual acuity (UCDVA), postoperative RA, and SE at one month. SPSS Version-21 was used; P < 0.05 considered significant. Results: Thirty eyes of 29 patients were included. Mean arithmetic and mean absolute PEs for RA were comparable between BTC (-0.70 ± 0.35D; 0.70 ± 0.34D) and IA (0.77 ± 0.32D; 0.80 ± 0.39D) (P = 0.09 and 0.09, respectively). Mean arithmetic PE for residual SE was significantly lower for BTC (-0.14 ± 0.32D) than IA (0.001 ± 0.33D) (-0.14 ± 0.32D; P = 0.002); however, there was no difference between respective mean absolute PEs (0.27 ± 0.21 D; 0.27 ± 0.18; P = 0.80). At one-month, mean UCDVA, RA, and SE were 0.09 ± 0.10D, -0.57 ± 0.26D, and -0.18 ± 0.27D, respectively. Conclusion: Both IA and BTC give reliable and comparable refractive results for tIOL implantation.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Aberrometria , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Refração Ocular , Córnea , Astigmatismo/cirurgia
15.
Sensors (Basel) ; 23(7)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37050594

RESUMO

Cataract or refractive lens surgery, along with the implantation of multifocal intraocular lenses (MF-IOL), enables a complete range of functional far, near and intermediate vision. Refractive, diffractive and extended depth of focus (EDoF) or combination of these principles represent the technology used to obtain this multifocality. Aberrometry makes it possible to study the aberrations induced by MF-IOLs. Among the different optical principles available to measure ocular aberrations, pyramidal wavefront-based sensor (PWS) aberrometry shows the highest resolution with MF-IOLs. Retinal image quality measured by a PWS aberrometer differed significantly according to the technology of the implanted lens. Monofocal and diffractive lenses showed the highest values of far-distance retinal image quality, followed by refractive and EDoF lenses; however, retinal image quality analysed in diffractive lenses appears to be more dependent on residual refractive error. Considering this limitation, PWS-aberrometry could be used to compare diffractive lenses. Nevertheless, further studies are needed to provide additional information about the clinical retinal image quality of MF-IOLs and to help surgeons in the important preoperative selection of IOLs.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Acuidade Visual , Implante de Lente Intraocular , Aberrometria , Desenho de Prótese
16.
Indian J Ophthalmol ; 71(2): 530-534, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36727355

RESUMO

Purpose: To evaluate the per operative intra-ocular lens (IOL) power calculation using intra-operative aberrometry (ORA) and its comparison with conventional methods. Methods: Patients with cataract planned for phacoemulsification by a single surgeon under topical anesthesia were enrolled in this prospective observational study in this prospective observational study. All patients underwent pre-operative biometry (Manual SRK-II and IOLMaster® 500) to determine the intra-ocular lens (IOL) power. Intra-operative aberrometry using ORA was also performed; however, IOL was inserted according to IOLMaster® (SRK/T). Spherical equivalent (SE) was recorded on post-operative days 1, 7, and 30. Patients were divided into three groups based on axial lengths for analysis. Comparative analysis was performed for the calculated IOL powers and prediction errors of ORA with conventional methods. Adjusted IOL power to calculate the emmetropic IOL using the LiHue formula was also determined and was compared with existing methods. A P-value less than 0.05 was considered statistically significant. Results: A total of 115 eyes from 113 patients were included, with a median age of 54.90 ± 14.3 years. The mean axial length was found to be 23.94 ± 2.3 mm. There was good agreement (87%) between ORA and IOLMaster® for calculated IOL powers with a mean difference of 0.047 ± 0.5D between the two (P = 0.33). A positive correlation was found between IOL power calculated using ORA, IOLMaster®, SRK-II, and adjusted IOL. Conclusion: The use of intra-operative aberrometry (ORA) to calculate IOL power in patients undergoing uncomplicated phacoemulsification is non-inferior relative to standard pre-operative measurement and planning.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Implante de Lente Intraocular , Aberrometria/métodos , Centros de Atenção Terciária , Refração Ocular , Biometria/métodos , Óptica e Fotônica , Estudos Retrospectivos
18.
Can J Ophthalmol ; 58(1): 2-10, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-34303640

RESUMO

OBJECTIVE: To compare the accuracy of intraoperative wavefront aberrometry to preoperative biometry formulae for predicting intraocular lens power. DESIGN: Retrospective, consecutive case series. PARTICIPANTS: Eyes undergoing cataract extraction with at least 1 month of follow-up after surgery at an ambulatory surgical centre in Toronto. METHODS: Consecutive sample of 228 cataract extractions with monofocal, trifocal, or toric intraocular lens implantation from November 1, 2017, to December 31, 2019. The spherical equivalent was predicted preoperatively with Barrett Universal II, Hill-Radial Basis Function (RBF), SRK/T, Holladay I, Holladay II, Haigis, and HofferQ using biometry measurements and intraoperatively with wavefront aberrometry. The primary outcomes were mean prediction error and proportion of eyes with a spherical equivalent within 0.5 D of the refractive target at postoperative month 1. RESULTS: The analysis included 159 eyes with 52% females and a mean age of 69.4 years. Formulae with the lowest mean prediction error were Hill-RBF (0.32 D ± 0.02 D), Barrett Universal II (0.32 D ± 0.02 D), intraoperative aberrometry (0.32 D ± 0.02 D), SRK/T (0.33 D ± 0.02 D), Holladay II (0.34 D ± 0.03 D), Holladay I (0.35 D ± 0.02 D), Haigis (0.37 D ± 0.02 D), and HofferQ (0.42 D ± 0.02 D). There were no statistically significant differences between intraoperative aberrometry and the preoperative formulae. Formulae with the highest proportion of eyes within 0.5 D of the refractive target were intraoperative aberrometry (82%), Barrett Universal II (81%), Hill-RBF (80%), SRK/T (77%), Holladay II (76%), Holladay I (75%), Haigis (71%), and HofferQ (70%). CONCLUSIONS: Intraoperative aberrometry and modern preoperative biometry formulae are equally effective at reaching the refractive target. In normal eyes, intraoperative aberrometry does not appear to provide any additional benefit to modern prediction formulae.


Assuntos
Extração de Catarata , Lentes Intraoculares , Facoemulsificação , Feminino , Humanos , Idoso , Masculino , Aberrometria , Estudos Retrospectivos , Refração Ocular , Biometria , Óptica e Fotônica
19.
Int Ophthalmol ; 43(4): 1353-1362, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36149621

RESUMO

PURPOSE: To evaluate the accuracy of different corneal parameters in detecting keratoconus using a dual Scheimpflug/Placido system (Sirius, CSO, Italy). METHODS: Sixty-eight eyes of 68 keratoconus patients and 77 eyes of 77 normal subjects were prospectively assessed in a diagnostic test study. The mean differences of the corneal parameters were compared using the independent t-test. The accuracy of curvature, elevation, pachymetry, and aberrometry indices, aqueous depth, and corneal volume in 10 mm was evaluated using the area under the curve (AUC), and the DeLong method was used for the comparison of AUCs. Multiple tests in a parallel manner and multiple logistic regression analysis were applied to determine the best predictor indices. RESULTS: All indices except aqueous depth and corneal volume were significantly different between the two groups (P < 0.001). Back keratoconus vertex (KVb) and front Baiocchi-Calossi-Versaci index (BCVf) had the highest sensitivity (for both 98.53%) followed by front symmetry index (SIf) (96.12%) and thinnest point of the cornea (88.24%) in elevation, aberrometry, curvature, and pachymetry parameters, respectively. The highest diagnostic ability was observed in KVb (AUC 0.993) and BCVf index (AUC 0.992) (DeLong > 0.05). Multiple test analysis showed a combination of indices with the highest accuracy that was similar to the performance of each one individually, and keratoconus was diagnosed correctly in 98.5% of the cases (R2 = 93%). CONCLUSION: The parameters extracted from Sirius can differentiate keratoconus from normal corneas with high accuracy without the need for complex computational algorithms. Elevation-based and combined aberrometry indices had the highest diagnostic power.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Topografia da Córnea/métodos , Paquimetria Corneana , Córnea , Aberrometria , Curva ROC
20.
Rev. bras. oftalmol ; 82: e0037, 2023. tab
Artigo em Português | LILACS | ID: biblio-1449771

RESUMO

RESUMO Objetivo Identificar alterações de aberrometria de alta ordem em diferentes graus de ceratocone. Métodos Estudo transversal, retrospectivo, observacional. Foram analisados 54 pacientes (108 olhos) diagnosticados com ceratocone pelo mesmo especialista em córnea por meio dos critérios ABCD de Belin/Ambrósio Enhanced Ectasia, utilizando-se o tomógrafo Pentacam® HR 70900 (Oculus Wetzlar, Alemanha). Além disso, foram feitas análises qualitativa e quantitativa das aberrações de alta ordem desses mesmos pacientes por meio do OPD-Scan III-NIDEK. Resultados Por meio da avaliação de ambos os olhos dos pacientes com os critérios de Belin-Ambrósio, constatou-se presença de ceratocone em 34 pacientes. Ademais, por meio da análise estatística, constatou-se relação direta entre a asfericidade posterior e o desenvolvimento do ceratocone, com p<0,001 (referência: p<0,05). Por meio da análise do OPD-Scan III-NIDEK, as principais aberrações de alta ordem encontradas nos pacientes com ceratocone foram coma, trefoil e aberração esférica. Conclusão O raio da curvatura posterior é a primeira variável a se alterar com o desenvolvimento do ceratocone, o que se faz perceptível na análise da asfericidade posterior por meio o Pentacam®. Além disso, a alteração da paquimetria e da asfericidade posterior influencia diretamente o desenvolvimento de aberrações de alta ordem em pacientes com ceratocone.


ABSTRACT Objective To identify higher order aberrometry changes in different degrees of keratoconus. Methods Cross-sectional, retrospective, observational study. Fifty-four patients (108 eyes) diagnosed with keratoconus by the same corneal specialist using the Belin/Ambrósio Enhanced Ectasia ABCD criteria were analyzed, using the Pentacam® HR 70900 tomograph (Oculus Wetzlar, Germany). In addition, qualitative and quantitative analysis of higher order aberrations in these patients was performed using the OPD-Scan III-NIDEK. Results Through the evaluation of both eyes of the patients according to the criteria of Benin Ambrósio, the presence of KCN was verified in 34 patients. Furthermore, through statistical analysis, a direct relationship was found between posterior asphericity and the development of KCN; p<0.001 (reference: p<0.05). Through the analysis of the OPD scan, the main higher order aberrations found in patients with KCN were Coma, Trefoil and Spherical Aberration (AE). Conclusion The posterior curvature radius is the first variable to change with the development of the KCN, which is noticeable in the analysis of posterior asphericity in Pentacam. In addition, alterations in pachymetry and posterior asphericity directly influence the development of higher order aberrations in patients with KCN.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Aberrometria/métodos , Ceratocone/diagnóstico , Acuidade Visual , Prontuários Médicos , Estudos Transversais , Estudos Retrospectivos , Dilatação Patológica , Paquimetria Corneana , Estudo Observacional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA