Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.632
Filtrar
1.
Pak J Pharm Sci ; 37(2): 405-416, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38767108

RESUMO

To develop a new kind of famotidine-resin microcapsule for gastric adhesion sustained release by screening out suitable excipients and designing reasonable prescriptions to improve patient drug activities to achieve the expected therapeutic effect. The famotidine drug resin was prepared using the water bath method with carbomer 934 used as coating material. Microcapsules were prepared using the emulsified solvent coating method and appropriate excipients were used to prepare famotidine sustained release suspension. Pharmacokinetics of the developed microcapsules were studied in the gastrointestinal tract of rats. The self-made sustained-release suspension of famotidine hydrochloride effectively reduced the blood concentration and prolonged the action time. The relative bioavailability of the self-made suspension of the famotidine hydrochloride to the commercially available famotidine hydrochloride was 146.44%, with an average retention time of about 5h longer, which indicated that the new suspension had acceptable adhesion properties. The findings showed that the newly developed famotidine-resin microcapsule increased the bioavailability of the drug with a significant sustained-release property.


Assuntos
Disponibilidade Biológica , Preparações de Ação Retardada , Famotidina , Famotidina/farmacocinética , Famotidina/administração & dosagem , Famotidina/química , Famotidina/farmacologia , Animais , Ratos , Masculino , Excipientes/química , Suspensões , Cápsulas , Liberação Controlada de Fármacos , Resinas Acrílicas/química , Antagonistas dos Receptores H2 da Histamina/farmacocinética , Antagonistas dos Receptores H2 da Histamina/administração & dosagem , Antagonistas dos Receptores H2 da Histamina/farmacologia , Antagonistas dos Receptores H2 da Histamina/química , Adesividade , Composição de Medicamentos , Acrilatos
2.
Chemosphere ; 358: 142235, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38705416

RESUMO

Ultraviolet (UV) radiation is a major contributor to skin aging, cancer, and other detrimental health effects. Sunscreens containing FDA-approved UV filters, like avobenzone, offer protection but suffer from photodegradation and potential phototoxicity. Encapsulation, antioxidants, and photostabilizers are strategies employed to combat these drawbacks. Octocrylene, an organic UV filter, utilizes nanotechnology to enhance sun protection factor (SPF). This review examines recent literature on octocrylene-enriched sunscreens, exploring the interplay between environmental impact, nanotechnological advancements, and clinical trial insights. A critical focus is placed on the environmental consequences of sunscreen use, particularly the potential hazards UV filters pose to marine ecosystems. Research in the Mediterranean Sea suggests bacterial sensitivity to these filters, raising concerns about their integration into the food chain. This review aims to guide researchers in developing effective strategies for photostabilization of UV filters. By combining encapsulation, photostabilizers, and antioxidants, researchers can potentially reduce phototoxic effects and contribute to developing more environmentally friendly sunscreens.


Assuntos
Protetores Solares , Raios Ultravioleta , Protetores Solares/química , Protetores Solares/toxicidade , Humanos , Acrilatos/química , Nanotecnologia , Antioxidantes/química , Fator de Proteção Solar
3.
Int J Mol Sci ; 25(7)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38612383

RESUMO

Polyacrylic acid (PAA), an organic chemical, has been used as an intermediate in the manufacture of pharmaceuticals and cosmetics. It has been suggested recently that PAA has a high pulmonary inflammatory and fibrotic potential. Although endoplasmic reticulum stress is induced by various external and intracellular stimuli, there have been no reports examining the relationship between PAA-induced lung injury and endoplasmic reticulum stress. F344 rats were intratracheally instilled with dispersed PAA (molecular weight: 269,000) at low (0.5 mg/mL) and high (2.5 mg/mL) doses, and they were sacrificed at 3 days, 1 week, 1 month, 3 months and 6 months after exposure. PAA caused extensive inflammation and fibrotic changes in the lungs' histopathology over a month following instillation. Compared to the control group, the mRNA levels of endoplasmic reticulum stress markers Bip and Chop in BALF were significantly increased in the exposure group. In fluorescent immunostaining, both Bip and Chop exhibited co-localization with macrophages. Intratracheal instillation of PAA induced neutrophil inflammation and fibrosis in the rat lung, suggesting that PAA with molecular weight 269,000 may lead to pulmonary disorder. Furthermore, the presence of endoplasmic reticulum stress in macrophages was suggested to be involved in PAA-induced lung injury.


Assuntos
Acrilatos , Lesão Pulmonar , Polímeros , Ratos , Animais , Ratos Endogâmicos F344 , Estresse do Retículo Endoplasmático , Inflamação , Pulmão
4.
J Bacteriol ; 206(4): e0004224, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38563759

RESUMO

In Salmonella enterica, the absence of the RidA deaminase results in the accumulation of the reactive enamine 2-aminoacrylate (2AA). The resulting 2AA stress impacts metabolism and prevents growth in some conditions by inactivating a specific target pyridoxal 5'-phosphate (PLP)-dependent enzyme(s). The detrimental effects of 2AA stress can be overcome by changing the sensitivity of a critical target enzyme or modifying flux in one or more nodes in the metabolic network. The catabolic L-alanine racemase DadX is a target of 2AA, which explains the inability of an alr ridA strain to use L-alanine as the sole nitrogen source. Spontaneous mutations that suppressed the growth defect of the alr ridA strain were identified as lesions in folE, which encodes GTP cyclohydrolase and catalyzes the first step of tetrahydrofolate (THF) synthesis. The data here show that THF limitation resulting from a folE lesion, or inhibition of dihydrofolate reductase (FolA) by trimethoprim, decreases the 2AA generated from endogenous serine. The data are consistent with an increased level of threonine, resulting from low folate levels, decreasing 2AA stress.IMPORTANCERidA is an enamine deaminase that has been characterized as preventing the 2-aminoacrylate (2AA) stress. In the absence of RidA, 2AA accumulates and damages various cellular enzymes. Much of the work describing the 2AA stress system has depended on the exogenous addition of serine to increase the production of the enamine stressor. The work herein focuses on understanding the effect of 2AA stress generated from endogenous serine pools. As such, this work describes the consequences of a subtle level of stress that nonetheless compromises growth in at least two conditions. Describing mechanisms that alter the physiological consequences of 2AA stress increases our understanding of endogenous metabolic stress and how the robustness of the metabolic network allows perturbations to be modulated.


Assuntos
Salmonella enterica , Scrapie , Ovinos , Animais , Salmonella enterica/genética , Acrilatos/metabolismo , Proteínas de Bactérias/genética , Fosfato de Piridoxal/metabolismo , Tetra-Hidrofolatos/metabolismo , Serina/metabolismo
5.
Eur J Pharm Biopharm ; 199: 114299, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38643953

RESUMO

Lipid-polymer nanoparticles offer a promising strategy for improving gene nanomedicines by combining the benefits of biocompatibility and stability associated with the individual systems. However, research to date has focused on poly-lactic-co-glycolic acid (PLGA) and resulted in inefficient transfection. In this study, biocompatible Eudragit constructs E100 and RS100 were formulated as lipid-polymer nanoparticles loaded with pDNA expressing red fluorescent protein (RFP) as a model therapeutic. Using a facile nanoprecipitation technique, a core-shell structure stabilised by lipid-polyethylene glycol (PEG) surfactant was produced and displayed resistance to ultracentrifugation. Both cationic polymers E100 (pH-sensitive dissolution at 5) and RS100 (pH-insensitive dissolution) produced 150-200 nm sized particles with a small positive surface charge (+3-5 mV) and high pDNA encapsulation efficiencies (EE) of 75-90%. The dissolution properties of the Eudragit polymers significantly impacted the biological performance in human embryonic kidney cells (HEK293T). Nanoparticles composed of polymer RS100 resulted in consistently high cell viability (80-100%), whereas polymer E100 demonstrated dose-dependent behaviour (20-90% cell viability). The low dissolution of polymer RS100 over the full pH range and the resulting nanoparticles failed to induce RFP expression in HEK293T cells. In contrast, polymer E100-constructed nanoparticles resulted in reproducible and gradually increasing RFP expression of 26-42% at 48-72 h. Intraperitoneal (IP) injection of the polymer E100-based nanoparticles in C57BL/6 mice resulted in targeted RFP expression in mouse testes with favourable biocompatibility one-week post-administration. These findings predicate Eudragit based lipid-polymer nanoparticles as a novel and effective carrier for nucleic acids, which could facilitate pre-clinical evaluation and translation of gene nanomedicines.


Assuntos
DNA , Nanopartículas , Plasmídeos , Transfecção , Humanos , Animais , Nanopartículas/química , Concentração de Íons de Hidrogênio , Plasmídeos/administração & dosagem , Transfecção/métodos , Células HEK293 , Camundongos , DNA/administração & dosagem , DNA/química , Lipídeos/química , Polímeros/química , Solubilidade , Tamanho da Partícula , Polietilenoglicóis/química , Proteína Vermelha Fluorescente , Ácidos Polimetacrílicos/química , Masculino , Acrilatos
6.
Environ Pollut ; 350: 124019, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38663506

RESUMO

Lead(II) is a potential carcinogen of heavy-metal ions (HIs). With the wide application of Pb-bearing products including lead alloy products, and new-energy lead-ion batteries, lead pollution has become a tricky problem. To solve such a difficulty, novel ultrathin MoS2-vinyl hybrid membranes (MVHMs) with a "spring" effect were synthesized via co-polymerization of acrylic acid, styrene and molybdenum disulfide (MoS2) and their adsorptions for HIs were explored. The "spring" effect derived from the interaction between the tendency of the short polyacrylic acid (PAA) chain connected with MoS2 to spread outward and the coulomb force between layers from MoS2 (s-MoS2), which enlarge the spacing of MoS2 layers without changing the number of layers after membrane formation, which changes the swelling membrane to a dense membrane and reduces the original thickness from 0.5 cm to 0.011 mm in the thickness direction. The adsorption experiment revealed that these MVHMs had super adsorption performance and high selectivity for Pb2+ by comparison with other five metal ions: Cu2+, Cd2+, Ni2+, Cr3+ and Zn2+. Especially, the adsorption quantity of MVHMs for Pb2+ could approach 2468 mg/g and the maximum adsorption ratio of qe[Pb2+]/qe[Cu2+] can reach 10.909. These values were much larger than the data obtained with the adsorbents reported in the last decade. A variety of models are applied to evaluate the effect of ionic groups. It was confirmed that -COOH plays a key role in adsorption of HIs and s-MoS2 also has a certain contribution. Conversely, ion exchange plays only a minor role during the period of adsorption process. Effective diffusion coefficient (Deff) of Pb(II) had the largest values among these metal ions. Hence, these hybrid membranes are promising adsorbents for the removal of Pb2+ from water containing various ions.


Assuntos
Acrilatos , Dissulfetos , Chumbo , Molibdênio , Estireno , Molibdênio/química , Chumbo/química , Adsorção , Acrilatos/química , Dissulfetos/química , Estireno/química , Polimerização , Membranas Artificiais , Poluentes Químicos da Água/química , Metais Pesados/química
7.
Soft Matter ; 20(17): 3666-3675, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38623704

RESUMO

Hydrogel-based flexible electronic devices serve as a next-generation bridge for human-machine interaction and find extensive applications in clinical therapy, military equipment, and wearable devices. However, the mechanical mismatch between hydrogels and human tissues, coupled with the failure of conformal interfaces, hinders the transmission of information between living organisms and flexible devices, which resulted in the instability and low fidelity of signals, especially in the acquisition of electromyographic (EMG) and electrocardiographic (ECG) signals. In this study, we designed an ion-conductive hydrogel (ICHgel) utilizing multiple physical interactions, successfully applied for human motion monitoring and the collection of epidermal physiological signals. By incorporating fumed silica (F-SiO2) nanoparticles and calcium chloride into an interpenetrating network (IPN) composed of polyvinyl alcohol (PVA) and polyacrylamide (AAm)/acrylic acid (AA) chains, the ICHgel exhibited exceptional tunable stretchability (>1450% strain) and conductivity (10.58 ± 0.85 S m-1). Additionally, the outstanding adhesion of the ICHgel proved to be a critical factor for effective communication between epidermal tissues and flexible devices. Demonstrating its capability to acquire stable electromechanical signals, the ICHgel was attached to different parts of the human body. More importantly, as a flexible electrode, the ICHgel outperformed commercial Ag/AgCl electrodes in the collection of ECG and EMG signals. In summary, the synthesized ICHgel with its outstanding conformal interface capabilities and mechanical adaptability paves the way for enhanced human-machine interaction, fostering the development of flexible electronic devices.


Assuntos
Acrilatos , Condutividade Elétrica , Hidrogéis , Humanos , Hidrogéis/química , Dispositivos Eletrônicos Vestíveis , Resinas Acrílicas/química , Álcool de Polivinil/química , Eletromiografia , Eletrocardiografia , Adesivos/química , Dióxido de Silício/química , Eletrodos
8.
Environ Pollut ; 349: 123921, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38574948

RESUMO

The surface functional groups of hydrochar are crucial to its surface properties, and their contents are strongly positively correlated with the adsorption performance. In this study, acrylate-functionalized hydrochar (AHC) with varying contents of O-containing functional groups (OFGs) was synthesized via hydrothermal carbonization (HTC) of bamboo, acrylic acid and an initiator, and then deprotonated with NaOH. The AHCs were analyzed by various characterization techniques. During HTC, the higher amount of acrylic acid added led to higher carbon, oxygen and carboxyl contents, and to the larger specific surface area and pore volume of AHC. The adsorption kinetics, isotherms, thermodynamic, ionic strength and pH effects of Pb(II) on AHC were studied. Adsorption isotherms and kinetics obeyed Langmuir and pseudo-second-order models, respectively, indicating adsorption is monolayer chemical process. The adsorptive ability was well linearly related to the OFG contents of AHC. When acrylic acid was added to 25 mL during HTC, the adsorbing ability of AHC over Pb(II) reached 193.90 mg g-1. Hence, direct HTC of acrylic acid, biomass and an initiator can prepare hydrochar with controllable OFG contents, which is a prospective adsorbent for treating metal cations.


Assuntos
Acrilatos , Chumbo , Oxigênio , Poluentes Químicos da Água , Adsorção , Acrilatos/química , Chumbo/química , Poluentes Químicos da Água/química , Cinética , Oxigênio/química , Carvão Vegetal/química , Termodinâmica , Concentração de Íons de Hidrogênio
9.
Acta Derm Venereol ; 104: adv19676, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551376

RESUMO

Allergic contact dermatitis is reported among individuals using continuous glucose monitoring systems and insulin pumps. The aim of this study was to describe contact allergy patterns for allergens in the Swedish baseline series and medical device-related allergens among users. Contact allergy to baseline series allergens and isobornyl acrylate was compared between diabetes patients and dermatitis patients patch-tested at the Department of Occupational and Environmental Dermatology during 2017 to 2020. Fifty- four diabetes patients and 2,567 dermatitis patients were included. The prevalence of contact allergy to fragrance mix II and sesquiterpene lactone mix was significantly higher in diabetes patients compared with dermatitis patients. Of the diabetes patients 13.0% and of the dermatitis patients 0.5% tested positive to sesquiterpene lactone mix (p < 0.001). Of the diabetes patients 7.4% and of the dermatitis patients 2.3% tested positive to fragrance mix II (p = 0.041). Of the diabetes patients 70.4% tested positive to medical device-related allergens. Of the diabetes patients 63.0% and of the dermatitis patients 0.2% were allergic to isobornyl acrylate (p < 0.001). In conclusion, not only medical device-related contact allergies, but also contact allergy to baseline series allergens (fragrance mix II and sesquiterpene lactone mix), is overrepresented in diabetes patients who use medical devices.


Assuntos
Acrilatos , Canfanos , Dermatite Alérgica de Contato , Diabetes Mellitus , Sesquiterpenos , Humanos , Alérgenos/efeitos adversos , Estudos Retrospectivos , Suécia/epidemiologia , Automonitorização da Glicemia , Glicemia , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Testes do Emplastro , Lactonas
10.
Acta Biomater ; 179: 130-148, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38460932

RESUMO

Poor skin adhesion and mechanical properties are common problems of pressure-sensitive adhesive (PSA) in transdermal drug delivery system (TDDS). Its poor water compatibility also causes the patch to fall off after sweating or soaking in the application site. To solve this problem, poly (2-Ethylhexyl acrylate-co-N-Vinyl-2-pyrrolidone-co-N-(2-Hydroxyethyl)acrylamide) (PENH), a cross-linked pyrrolidone polyacrylate PSA, was designed to improve the adhesion and water resistance of PSA through electrostatic force and hydrogen bonding system. The structure of PENH was characterized by 1H NMR, FTIR, DSC, and other methods. The mechanism was studied by FTIR, rheological test, and molecular simulation. The results showed that the PENH patch could adhere to human skin for more than 10 days without cold flow, and it could still adhere after sweating or water contact. In contrast, the commercial PSA Duro-Tak® 87-4098 and Duro-Tak® 87-2852 fell off completely on the 3rd and 6th day, respectively, and Duro-Tak® 87-2510 showed a significant dark ring on the second day. Mechanism studies have shown that the hydrogen bond formed by 2-ethylhexyl acrylate (2-EHA), N-vinyl-2-pyrrolidinone (NVP), and N-(2-Hydroxyethyl)acrylamide (HEAA) enhances cohesion, the interaction with skin improves skin adhesion, and the electrostatic interaction with water or drug molecules enhances the ability of water absorption and drug loading. Due to the synergistic effect of hydrogen bonds and electrostatic force, PENH can maintain high cohesion after drug loading or water absorption. PENH provides a choice for the development of water-compatible patches with long-lasting adhesion. STATEMENT OF SIGNIFICANCE: Based on the synergistic effect of hydrogen bonding and electrostatic force, a hydrogen-bonded, cross-linked pyrrolidone acrylate pressure-sensitive adhesive for transdermal drug delivery was designed and synthesized, which has high adhesion and cohesive strength and is non-irritating to the skin. The patch can be applied on the skin surface continuously for more than 10 days without the phenomenon of "dark ring", and the patch can remain adherent after the patient sweats or bathes. This provides a good strategy for choosing a matrix for patches that require prolonged administration.


Assuntos
Adesivos , Administração Cutânea , Ligação de Hidrogênio , Pirrolidinonas , Eletricidade Estática , Água , Adesivos/química , Adesivos/farmacologia , Água/química , Humanos , Pirrolidinonas/química , Pressão , Animais , Acrilatos/química , Sistemas de Liberação de Medicamentos , Pele/efeitos dos fármacos , Pele/metabolismo , Reagentes de Ligações Cruzadas/química
11.
J Adhes Dent ; 26(1): 87-92, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38465403

RESUMO

PURPOSE: This paper describes previously unknown details about the discovery of resin adhesion to acid-etched human enamel. MATERIALS AND METHODS: A literature review was performed through manual assessments. Primary sources revealing the discovery of resin curing on etched enamel were analyzed considering the research objectives and methodological procedure during that era, including the type of teeth used, preparatory measures, acid-etching process, type of resin and its application, and follow-up observations. Additionally, the political and economic contexts were examined. RESULTS: In 1949, acid etching was found to promote adhesion with acrylic resin, a finding described again in 1955. The 1949 studies utilized nitric acid for enamel etching and the acrylate resin Paladon from the Kulzer company (Germany). Conversely, the 1955 investigations employed phosphoric acid and an unnamed acrylate, likely a self-curing resin supported by Kulzer in the late 1930s. Disparities in the 1949 and 1955 findings can be ascribed to varying objectives and test conditions amidst a turbulent political backdrop, significantly impacting the Kulzer company. CONCLUSION: The discovery of resin adhesion to acid-etched enamel, approaching its 75th anniversary in 2024, is a landmark in 20th-century adhesive dentistry. Paladon represents a pioneering compound, exemplifying the influence of political, ideological, and economic factors on scientific advancements during that period.


Assuntos
Colagem Dentária , Humanos , Condicionamento Ácido do Dente/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Esmalte Dentário , Ácidos Fosfóricos , Acrilatos , Cimentos de Resina , Teste de Materiais
12.
Niger J Clin Pract ; 27(3): 304-309, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38528349

RESUMO

BACKGROUND AND AIM: Gastroesophageal reflux disease causes gastric acid to enter the oral cavity, leading to mucosal changes and deterioration of dental hard tissues and materials. The purpose of this in vitro study was to evaluate the impact of gastric juice on the surface roughness of two types of acrylics used in provisional restorations. MATERIALS AND METHODS: Acrytemp ® and Temdent acrylic resin discs (10 × 2 mm) totaling 80 were manufactured and divided into eight groups (n = 10). Groups were prepared as follows: Group 1 (Temdent + Universal Polish) (control), Group 2 (Temdent + Universal Polish + Biscover LV), Group 3 (Temdent + Universal Polish + Resin Glaze), Group 4 (Temdent + Universal Polish + Fortify Plus), Group 5 (Acrytemp + Universal Polish) (control), Group 6 (Acrytemp + Universal Polish + Biscover LV), Group 7 (Acrytemp + Universal Polish + Resin Glaze), and Group 8 (Acrytemp + Universal Polish + Fortify Plus). The resin discs were immersed in distilled water for 24 h and in gastric juice (pH = 2) for additional 24 h. The initial and final roughness values of samples were measured and analyzed with non-parametric statistics including Mann-Whitney U-test for pairwise comparison, Kruskall Wallis test for comparing more than two groups, and Wilcoxon signed rank test for within-group comparison (P < 0.05). RESULTS: Surface roughness did not differ significantly between control groups. It notably increased for all samples with surface sealants, both initially and after gastric juice immersion (P < 0.05). CONCLUSION: Surface sealants noticeably increased the roughness of two types of acrylic resins. After immersing in gastric juice, Group 4 (Temdent + Universal Polish + Fortify Plus) showed the highest roughness, while the untreated control groups remained the smoothest.


Assuntos
Acrilatos , Resinas Acrílicas , Resinas Compostas , Cimentos de Resina , Humanos , Propriedades de Superfície , Teste de Materiais , Suco Gástrico , Materiais Dentários
13.
Int J Biol Macromol ; 265(Pt 2): 131115, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38522691

RESUMO

A cellulose-reinforced eutectogel was constructed by deep eutectic solvent (DES) and cotton linter cellulose. Cellulose was dispersed in the ternary DES consisting of acrylic acid, choline chloride and AlCl3·6H2O. The photoinitiator was then introduced into the system to in situ polymerize acrylic acid monomer to form transparent and ionic conductive eutectogels while keeping all the DES. The crosslinks formed by Al3+ induced ionic bonds and reversible links formed by hydrogen bonds give the eutectogels high stretchability (3200 ± 200 % tensile strain), self-adhesive (52.1 kPa to glass), self-healing and good mechanical strength (670 kPa). The eutectogels were assembled into sensors and epidermal patch electrodes that demonstrated high quality human motion sensing and physiological signal detection (electrocardiogram and electromyography). This work provides a facile way to design flexible electronics for sensing.


Assuntos
Acrilatos , Celulose , Humanos , Colina , Condutividade Elétrica
14.
J Prosthet Dent ; 131(4): 708.e1-708.e8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38383280

RESUMO

STATEMENT OF PROBLEM: Removable dental prostheses require periodic relining with the loss of intaglio surface fit because of mucosal shape changes over time. Therefore, a new material with high adaptability to tissue changes over time would be beneficial. PURPOSE: This study focused on a shape-memory gel (SMG) that softens when heated, retains its shape when cooled, and returns to its original shape when reheated. The purpose was to optimize SMG for intraoral use by controlling the ratio of 2 acrylate monomers and to evaluate the changes in the shape memory and physical properties of SMG with temperature and to evaluate biocompatibility. MATERIAL AND METHODS: SMG specimens were synthesized using the following mixing ratios of 2 monomers, docosyl acrylate (DA) and stearyl acrylate (SA): 0:100, 25:75, 50:50, 75:25, and 100:0. SMG specimens were photopolymerized using a fluorescent light-polymerizing unit. To evaluate shape memory as a function of temperature, permanent deformation was measured based on the standardized compression set test for thermoplastic rubber. For evaluation of the physical properties and cytotoxicity, a 3-dimensionally printed denture base material was used as the control material. All assessments were compared between the groups by using 1-way analysis of variance followed by the Tukey-Kramer multiple comparison test (α=.05). RESULTS: SMGs with a higher amount of DA maintained their compressed shape at room and intraoral temperatures. However, the SMG matrices softened and recovered their original shapes above 60 °C. SMGs showed Shore A hardness equivalent to that of the denture-base polymer material at intraoral temperatures because of the high phase-transition temperature. The low water solubility of SMGs supported the biocompatibility test results. CONCLUSIONS: SMG, in which the phase-transition temperature was controlled by mixing acrylate monomers with different melting points, exhibited shape memory in the intraoral environment. The results indicate the feasibility of applying SMG for the fabrication of removable dental prostheses because of its high adaptability to tissue changes over time and biocompatibility.


Assuntos
Acrilatos , Prótese Dentária , Temperatura , Temperatura de Transição , Teste de Materiais
16.
Contact Dermatitis ; 90(5): 495-500, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38316128

RESUMO

BACKGROUND: Allergic contact dermatitis (ACD) has been reported as an adverse effect from the use of several glucose sensors and insulin pumps from different manufacturers. Isobornyl acrylate (IBOA) has been identified as a major culprit sensitizer, but also other acrylates and (modified) colophonium have been reported as causes of ACD. OBJECTIVES: To report the two first cases diagnosed with ACD caused by the Dexcom G7 (DG7) glucose sensor. PATIENTS AND METHODS: Two children with suspected ACD from DG7 were patch tested with our medical device series with an addition of selected test preparations including two variants of modified colophonium - methyl hydrogenated rosinate (MHR) and glyceryl hydrogenated rosinate (GHR). Both patients were also tested with acetone extracts made from different parts of the DG7 sensor. The extracts were analysed by gas chromatography-mass spectrometry (GC-MS). RESULTS: Both patients tested positive to IBOA, hydroabietyl alcohol and GHR. In addition, patient 1 had a positive reaction to MHR and patient 2 had a positive reaction to colophonium. The GC-MS analyses showed the presence of IBOA and colophonium-related substances in the DG7 extracts. CONCLUSIONS: Both patients were diagnosed with contact allergy to well-known medical device-related sensitizers. The presence of IBOA and (modified) colophonium in a newly introduced (on the Swedish market in 2023) glucose sensor is remarkable and indicates an inadequate toxicological assessment of the materials used in the sensor.


Assuntos
Alérgenos , Canfanos , Dermatite Alérgica de Contato , Criança , Humanos , Alérgenos/efeitos adversos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Automonitorização da Glicemia/efeitos adversos , Adesivos/efeitos adversos , Acrilatos/efeitos adversos , Glucose , Testes do Emplastro/efeitos adversos
17.
Contact Dermatitis ; 90(5): 501-506, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38332444

RESUMO

BACKGROUND: Many people live with ostomies after life-saving surgery. Ostomy patients often suffer from peristomal dermatitis. Allergic contact dermatitis (ACD) has been reported, mostly due to contact allergy (CA) to topical agents. OBJECTIVES: We present three patients with therapy resistant peristomal dermatitis, suggesting ACD caused by different stoma products. METHODS: Patch testing was performed with baseline series, additional series, and selected allergens. They were also tested with their own ostomy products as is and separate extracts of the products. Extracts were analysed using Gas Chromatography-Mass Spectrometry (GC-MS). RESULTS: In all three patients we diagnosed CA to 1,6-hexanediol diacrylate (HDDA), +++ in case (C) 1 and 3, ++ in C 2. HDDA was detected in C 2's ostomy pouch adhesive and in C 1's and 3's flange extenders used to improve the adhesion of the ostomy pouches. CONCLUSION: Therapy resistant peristomal dermatitis should always be suspected of ACD and patch testing, especially with the patient's own products, should be performed.


Assuntos
Dermatite Alérgica de Contato , Estomia , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/etiologia , Estomia/efeitos adversos , Acrilatos/efeitos adversos , Alérgenos/efeitos adversos , Testes do Emplastro/métodos
18.
Contact Dermatitis ; 90(5): 507-513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38351475

RESUMO

BACKGROUND: A global epidemic of allergic contact dermatitis to (meth)acrylates has been described in relation to the widespread use of manicure products. OBJECTIVES: To evaluate the frequency of sensitization to 2-hydroxyethyl methacrylate (2-HEMA) among consecutively patch tested patients with eczema in Spain; the percentage of current relevance; the MOAHLFA index; and, the potential sources of exposure to (meth)acrylates. METHODS: From January 2019 to December 2022, 2-HEMA 2% pet. was prospectively patch tested in 24 REIDAC (Spanish Allergic Contact Dermatitis Registry) centres. RESULTS: Six thousand one hundred thirty-four patients were consecutively patch tested with 2-HEMA 2% pet. 265/6134 (4.3%) were positive. Positive reactions of current relevance were identified to involve 184/265 (69%). The efficiency (number of patch tests needed to detect relevant positive patch test reactions) was 34 (6134/184). The variable 'occupational' was found to be significantly associated with a higher risk for relevant positive reactions to 2-HEMA (OR: 10.9; 95% CI: 8.1-14.9). CONCLUSION: (Meth)acrylate sensitization is a prevalent health issue in Spain. 2-HEMA 2% pet. has been identified to be a highly effective (meth)acrylate allergy marker in the GEIDAC baseline series. The responsible authorities should implement policies guaranteeing accurate labelling of industrial, medical, and consumer materials while ensuring the enforcement of said labelling through appropriate legal means.


Assuntos
Dermatite Alérgica de Contato , Dermatite Ocupacional , Humanos , Dermatite Alérgica de Contato/diagnóstico , Dermatite Alérgica de Contato/epidemiologia , Dermatite Alérgica de Contato/etiologia , Espanha/epidemiologia , Metacrilatos/efeitos adversos , Acrilatos , Testes do Emplastro
19.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 55(1): 87-94, 2024 Jan 20.
Artigo em Chinês | MEDLINE | ID: mdl-38322512

RESUMO

Objective: To construct microscale rectangular hydrogel grooves and to investigate the morphology and alignment of human umbilical vein endothelial cells (HUVECs) under spatial constraints. Vascular endothelial cell morphology and alignment are important factors in vascular development and the maintenance of homeostasis. Methods: A 4-arm polyethylene glycol-acrylate (PEG-acrylate) hydrogel was used to fabricate rectangular microgrooves of the widths of 60 µm, 100 µm, and 140 µm. The sizes and the fibronectin (FN) adhesion of these hydrogel microgrooves were measured. HUVECs were seeded onto the FN-coated microgrooves, while the flat surface without micropatterns was used as the control. After 48 hours of incubation, the morphology and orientation of the cells were examined. The cytoskeleton was labelled with phalloidine and the orientation of the cytoskeleton in the hydrogel microgrooves was observed by laser confocal microscopy. Results: The hydrogel microgrooves constructed exhibited uniform and well-defined morphology, a complete structure, and clear edges, with the width deviation being less than 3.5%. The depth differences between the hydrogel microgrooves of different widths were small and the FN adhesion is uniform, providing a micro-patterned growth interface for cells. In the control group, the cells were arranged haphazardly in random orientations and the cell orientation angle was (46.9±1.8)°. In contrast, the cell orientation angle in the hydrogel microgrooves was significantly reduced (P<0.001). However, the cell orientation angles increased with the increase in hydrogel microgroove width. For the 60 µm, 100 µm, and 140 µm hydrogel microgrooves, the cell orientation angles were (16.4±2.8)°, (24.5±3.2)°, and (30.3±3.5)°, respectively. Compared to that of the control group (35.7%), the number of cells with orientation angles <30° increased significantly in the hydrogel microgrooves of different widths (P<0.001). However, as the width of the hydrogel microgrooves increased, the number of cells with orientation angles <30° gradually decreased (79.9%, 62.3%, 54.7%, respectively), while the number of cells with orientation angles between 60°-90° increased (P<0.001). The cell bodies in the microgrooves were smaller and more rounded in shape. The cells were aligned along the direction of the microgrooves and corresponding changes occurred in the arrangement of the cell cytoskeleton. In the control group, cytoskeletal filaments were aligned in random directions, presenting an orientation angle of (45.5±3.7)°. Cytoskeletal filaments were distributed evenly within various orientation angles. However, in the 60 µm, 100 µm, and 140 µm hydrogel microgrooves, the orientation angles of the cytoskeletal filaments were significantly decreased, measuring (14.4±3.1)°, (24.7±3.5)°, and (31.9±3.3)°, respectively. The number of cytoskeletal filaments with orientation angles <30° significantly increased in hydrogel microgrooves of different widths (P<0.001). However, as the width of the hydrogel microgrooves increased, the number of cytoskeletal filaments with orientation angles <30° gradually decreased, while the number of cytoskeletal filaments with orientation angles between 60°-90° gradually increased (P<0.001). Conclusion: Hydrogel microgrooves can regulate the morphology and orientation of HUVECs and mimic to a certain extent the in vivo microenvironment of vascular endothelial cells, providing an experimental model that bears better resemblance to human physiology for the study of the unique physiological functions of vascular endothelial cells. Nonetheless, the molecular mechanism of spatial constraints on the morphology and the assembly of vascular endothelial cell needs to be further investigated.


Assuntos
Acrilatos , Hidrogéis , Humanos , Células Endoteliais da Veia Umbilical Humana , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Adesão Celular
20.
J Chromatogr A ; 1717: 464708, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38330846

RESUMO

The Poly acrylic acid/MIL-88(Fe)-NH2 composite material, carefully prepared, is employed as a sorbent for the stir bar. The best formula of the composite was selected by investigation of two parameters including the cross-linker of PAA and MIL-88(Fe)-NH2 content. The prepared stir bar was used for extraction of 2-pentanone, 2-heptanone, ethyl propionate, para-xylene, 1,2,4-trimethylbenzene, o-cresol, m-cresol in urine samples as breast cancer biomarkers with gas chromatography-flame ionization detector. The prepared Poly acrylic acid / MIL-88(Fe)-NH2 as sorbent for the stir bar demonstrate good repeatability of one bar (relative standard deviation (RSD%) < 4.61 %) and satisfactory reproducibility between two bars (RSD% < 6.85 %). The central composite design method was applied for the optimization of extraction parameters. Under the optimum conditions, linear dynamic ranges for compounds were in the acceptable range with correlation coefficients higher than 0.99. Detection limits of them were less than 1.71 µg L-1.


Assuntos
Acrilatos , Biomarcadores Tumorais , Neoplasias da Mama , Humanos , Feminino , Reprodutibilidade dos Testes , Hidrogéis , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA