Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Rev. Soc. Bras. Clín. Méd ; 18(3): 171-173, mar 2020.
Artigo em Português | LILACS | ID: biblio-1361517

RESUMO

Este relato teve como objetivo apresentar um caso de elderly onset rheumatoid arthritis associada à trombocitose reacional significativa. À admissão, o paciente apresentava quadro de poliartrite de pequenas e grandes articulações associado à rigidez matinal. Após exames solicitados, evidenciaram-se trombocitose de 1.697.000 cel./mm³ e anticorpos antipeptídeos citrulinados positivos, sendo diagnosticado com artrite reumatoide do tipo elderly onset rheumatoid arthritis.


This report aimed at presenting a case of elderly-onset rheumatoid arthritis associated with significant reactive thrombocytosis. On admission, the patient presented polyarthritis of small and large joints associated with morning stiffness. After the performance of the requested tests, thrombocytosis of 1,697,000 cells/mm3 and positive anti-CCP were evidenced, and the patient was diagnosed with elderly-onset rheumatoid arthritis.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Artrite Reumatoide/diagnóstico , Trombocitose/diagnóstico , Artrite Reumatoide/complicações , Artrite Reumatoide/sangue , Fator Reumatoide/análise , Trombocitose/complicações , Trombocitose/sangue , Contagem de Células Sanguíneas , Sedimentação Sanguínea , Proteína C-Reativa/análise , Edema/etiologia , Anticorpos Antiproteína Citrulinada/isolamento & purificação
2.
Analyst ; 143(13): 3141-3147, 2018 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-29877533

RESUMO

We developed an assay for diagnosing rheumatoid arthritis (RA) by capillary electrophoresis with the laser-induced fluorescence detection (CE-LIF) of antibodies against cyclic citrullinated peptides (CCPs) using fluorescein isothiocyanate-labeled F-CCP11A and F-CCP. The CCPs were incubated overnight with a purified antibody against CCP and then injected into the CE-LIF system to estimate complex concentration. The immunocomplexes and free peptides were separated within 5 min; the LOD and LOQ values of the immunoassay are 0.1 µg mL-1 and 0.3 µg mL-1, respectively. The calibration curves for the immunocomplex had a coefficient of determination of 0.98. The reproducibility of the CE-LIF based immunoassay when using F-CCP11A and F-CCP was less than 5% and the accuracy ranged between 89 and 103%. The applicability of the assay was evaluated using serum samples from RA patients and healthy control subjects. We found that the sensitivity and specificity for RA diagnosis were 100% and 83.3%, respectively, for F-CCP11A and 100% and 90%, respectively, for F-CCP. These results demonstrate that the CE-LIF method can be useful for quantitative immunoassay development.


Assuntos
Anticorpos Antiproteína Citrulinada/isolamento & purificação , Artrite Reumatoide/diagnóstico , Eletroforese Capilar , Imunoensaio , Adulto , Idoso , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeos Cíclicos/imunologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA