Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.263
Filtrar
1.
Mikrochim Acta ; 191(7): 422, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38922459

RESUMO

Since 2017, an infectious goose gout disease characterized by urate precipitation in viscera, mainly caused by novel goose astrovirus (GoAstV) infection, has emerged in the main goose-producing region of China. The current challenge in managing goose gout disease is largely due to the absence of a rapid and efficient detection method for the GoAstV pathogen. Notably, the potential application of immunosensors in detecting GoAstV has not yet been explored. Herein, a label-free PEC immunosensor was fabricated by using purchased TiO2 as the photoactive material and antibody against GoAstV P2 proteins as the specific recognition element. First, we successfully expressed the capsid spike domain P2 protein of ORF2 from GoAstV CHSH01 by using the pET prokaryotic expression system. Meanwhile, the polyclonal antibody against GoAstV capsid P2 protein was produced by purified protein. To our knowledge, this is the first establishment and preliminary application of the label-free photoelectrochemical immunosensor method in the detection of AstV. The PEC immunosensor had a linear range of 1.83 fg mL-1 to 3.02 ng mL-1, and the limit of detection (LOD) was as low as 0.61 fg mL-1. This immunosensor exhibited high sensitivity, great specificity, and good stability in detecting GoAstV P2 proteins. To evaluate the practical application of the immunosensor in real-world sample detection, allantoic fluid from goose embryos was collected as test samples. The results indicated that of the eight positive samples, one false negative result was detected, while both negative samples were accurately detected, suggesting that the constructed PEC immunosensor had good applicability and practical application value, providing a platform for the qualitative detection of GoAstV.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Limite de Detecção , Titânio , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Animais , Imunoensaio/métodos , Titânio/química , Gansos , Proteínas do Capsídeo/imunologia , Proteínas do Capsídeo/química , Avastrovirus/química , Avastrovirus/imunologia , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química , Anticorpos Antivirais/imunologia , Processos Fotoquímicos
2.
ACS Appl Mater Interfaces ; 16(24): 30611-30621, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38857116

RESUMO

Polypyrrole (Ppy) is a biologically compatible polymer that is used as a matrix, in which drugs and enzymes can be incorporated by doping. Here, we suggest an inventive application of Ppy as a biorecognition film encapsulated with an antibody (Ab) as an alternative strategy for the on-site multistep functionalization of thiol-based self-assembled monolayers. The fabrication steps of the recognition films were followed by dropping pyrrole and Ab mixed solutions onto the electrode and obtaining a thin film by direct current electropolymerization. The efficiency of Ab immobilization was studied by using fluorescence microscopy and electrochemical (EC) methods. Finally, the Ab density was increased and immobilized in 1 min, and the sensing performance as an EC immunosensor was demonstrated using α-fetoprotein with a limit of detection of 3.13 pg/mL and sensing range from 1 pg/mL to 100 ng/mL. This study demonstrates the potential for electrochemical functionalization of biomolecules with high affinity and rapidity.


Assuntos
Anticorpos Imobilizados , Técnicas Eletroquímicas , Polímeros , Pirróis , Pirróis/química , Imunoensaio/métodos , Polímeros/química , Técnicas Eletroquímicas/métodos , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química , Técnicas Biossensoriais/métodos , Polimerização , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/imunologia , Eletrodos , Limite de Detecção , Humanos
3.
Anal Chim Acta ; 1314: 342781, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-38876519

RESUMO

BACKGROUND: Okadaic acid (OA), as a diarrhetic shellfish poisoning, can increase the risk of acute carcinogenic or teratogenic effects for the ingestion of OA contaminated shellfish. At present, much effort has been made to graft immunoassay onto a paper substrate to make paper-based sensors for rapid and simple detection of shellfish toxin. However, the complicated washing steps and low protein fixation efficiency on the paper substrate need to be further addressed. RESULTS: A novel paper-tip immunosensor for detecting OA was developed combined with smartphone and naked eye readout. The trapezoid paper tip was consisted of quantitative and qualitative detection zones. To improve the OA antigen immobilization efficiency on the paper substrate, graphene oxide (GO)-assisted protein immobilization method was introduced. Meanwhile, Au nanoparticles composite probe combined with the lateral flow washing was developed to simplify the washing step. The OA antigen-immobilized zone, as the detection zone Ⅰ, was used for quantitative assay by smartphone imaging. The paper-tip front, as the detection zone Ⅱ, which could qualitatively differentiate OA pollution level within 45 min using the naked eye. The competitive immunoassay on the paper tip exhibited a wide linear range for detecting OA (0.02-50 ng∙mL-1) with low detection limit of 0.02 ng∙mL-1. The recovery of OA in spiked shellfish samples was in the range of 90.3 %-113.%. SIGNIFICANCE: These results demonstrated that the proposed paper-tip immunosensor could provide a simple, low-cost and high-sensitivity test for OA detection without the need for additional large-scale equipment or expertise. We anticipate that this paper-tip immunosensor will be a flexible and versatile tool for on-site detecting the pollution of marine products.


Assuntos
Técnicas Biossensoriais , Ouro , Grafite , Ácido Okadáico , Papel , Smartphone , Grafite/química , Ácido Okadáico/análise , Imunoensaio/métodos , Ouro/química , Nanopartículas Metálicas/química , Proteínas Imobilizadas/química , Limite de Detecção , Animais , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
4.
Mikrochim Acta ; 191(7): 381, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858277

RESUMO

Nanosized sodium bismuth perovskite titanate (NBT) was synthesized and first used as the electrochemical immune sensing platform for the sensitive detection of carcinoembryonic antigen (CEA). Gold nanoparticles (Au NPs) grew on the surface of NBT through forming Au-N bond to obtain Au@NBT, and a label-free electrochemical immunosensor was proposed using Au@NBT as an immunosensing recognizer towards CEA. The well-ordered crystal structure of NBT was not changed at all after the modification of Au NPs outside, but significantly improved the conductivity, catalytic activity, and biocompatibility of the Au@NBT-modified electrode. The unique cubic crystal nanostructure of NBT offered a large active area for both Au NP modification and the subsequent immobilization of biomolecules over the electrode surface, triggering the effective generation of promising properties of the proposed Au@NBT-based electrochemical immunosensor. As expected, favorable detection performances were achieved using this immunosensor towards CEA detection, where a good linear relationship between the current response and CEA concentration was obtained in the concentration range 10 fg mL-1 to 100 ng mL-1 with a low detection limit (LOD) of 13.17 fg mL-1. Also, the significantly enhanced selectivity, and stability guaranteed the promising electrochemical properties of this immunosensor. Furthermore, the analysis of real serum samples verified the high feasibility of this new method in clinical CEA detection. This work opens a new window for the application of nanoperovskite in the early detection of CEA.


Assuntos
Bismuto , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Ouro , Limite de Detecção , Nanopartículas Metálicas , Titânio , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/imunologia , Titânio/química , Técnicas Eletroquímicas/métodos , Humanos , Imunoensaio/métodos , Ouro/química , Nanopartículas Metálicas/química , Bismuto/química , Técnicas Biossensoriais/métodos , Óxidos/química , Anticorpos Imobilizados/imunologia , Compostos de Cálcio/química , Eletrodos
5.
Mikrochim Acta ; 191(7): 387, 2024 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-38869719

RESUMO

A novel construction strategy is introduced for an ultrasensitive dynamic light scattering (DLS) immunosensor targeting alpha fetoprotein (AFP). This approach relies on a self-assembled heptamer fusion protein (A1-C4bpα), incorporating the dual functions of multivalent recognition and crosslinking aggregation amplification due to the presence of seven AFP-specific A1 nanobodies on the A1-C4bpα heptamer. Leveraging antibody-functionalized magnetic nanoparticles for target AFP capture and DLS signal output, the proposed heptamer-assisted DLS immunosensor offers high sensitivity, strong specificity, and ease of operation. Under the optimized conditions, the designed DLS immunosensor demonstrates excellent linear detection of AFP in the concentration range 0.06 ng mL-1 to 512 ng mL-1, with a detection limit of 15 pg mL-1. The selectivity, accuracy, precision, practicability, and reliability of this newly developed method were further validated through an assay of AFP levels in spiked and actual human serum samples. This work introduces a novel approach for constructing ultrasensitive DLS immunosensors, easily extendable to the sensitive determination of other targets via simply replacing the nanobody sequence, holding great promise in various applications, particularly in disease diagnosis.


Assuntos
Difusão Dinâmica da Luz , Limite de Detecção , alfa-Fetoproteínas , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/imunologia , Humanos , Imunoensaio/métodos , Anticorpos Imobilizados/imunologia , Técnicas Biossensoriais/métodos , Anticorpos de Domínio Único/química , Anticorpos de Domínio Único/imunologia , Nanopartículas de Magnetita/química
6.
Mikrochim Acta ; 191(7): 418, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38914884

RESUMO

An electrochemical immunoassay system was developed to detect CA-125 using a glassy carbon electrode (GCE) modified with MXene, graphene quantum dots (GQDs), and gold nanoparticles (AuNPs). The combined MXene-GQD/AuNPs modification displayed advantageous electrochemical properties due to the synergistic effects of MXene, GQDs, and AuNPs. The MXene-GQD composite in the modified layer provided strong mechanical properties and a large specific surface area. Furthermore, the presence of AuNPs significantly improved conductivity and facilitated the binding of anti-CA-125 on the modified GCE, thereby enhancing sensitivity. Various analytical techniques such as FE-SEM and EDS were utilized to investigate the structural and morphological characteristics as well as the elemental composition. The performance of the developed immunosensor was assessed using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), square wave voltammetry (SWV), and differential pulse voltammetry (DPV). Under optimized conditions in a working potential range of -0.2 to 0.6 V (vs. Ag/AgCl), the sensitivity, linear range (LR), limit of detection (LOD), and correlation coefficient (R2) were determined to be 315.250 µA pU.mL-1/cm2, 0.1 to 1 nU/mL, 0.075 nU/mL, and 0.9855, respectively. The detection of CA-125 in real samples was investigated using the developed immunoassay platform, demonstrating satisfactory results including excellent selectivity and reproducibility.


Assuntos
Antígeno Ca-125 , Técnicas Eletroquímicas , Ouro , Grafite , Limite de Detecção , Nanopartículas Metálicas , Neoplasias Ovarianas , Pontos Quânticos , Antígeno Ca-125/sangue , Antígeno Ca-125/análise , Ouro/química , Nanopartículas Metálicas/química , Humanos , Neoplasias Ovarianas/sangue , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Imunoensaio/métodos , Feminino , Pontos Quânticos/química , Grafite/química , Anticorpos Imobilizados/imunologia , Técnicas Biossensoriais/métodos , Eletrodos , Proteínas de Membrana
7.
Mikrochim Acta ; 191(7): 419, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38916771

RESUMO

A method is presented for chemiluminescence resonance energy transfer (CRET) using APTES-Fe3O4 as a highly efficient energy acceptor with strong magnetic effectiveness over extended distances, while an Au@BSA-luminol composite acts as the donor. In order to boost the chemiluminescence reactions, CuO nanoparticles were successfully employed. The distance between the donor and acceptor is a crucial factor in the occurrence of the CRET phenomenon. A sensitive and high-throughput sandwich chemiluminescence immunosensor has been developed accordingly with a linear range of 1.0 × 10-7 g/L to 6.0 × 10-5 g/L and a limit of detection of 0.8 × 10-7 g/L. The CRET-based sandwich immunosensor has the potential to be implemented to early cancer diagnosis because of its high sensitivity in detecting Nanog, fast analysis (30 min), and simplicity. Furthermore, this approach has the potential to be adapted for the recognition of other antigen-antibody immune complexes by utilizing the corresponding antigens and their selective antibodies.


Assuntos
Biomarcadores Tumorais , Proteína Homeobox Nanog , Humanos , Imunoensaio/métodos , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/imunologia , Biomarcadores Tumorais/análise , Proteína Homeobox Nanog/imunologia , Células-Tronco Neoplásicas/imunologia , Limite de Detecção , Medições Luminescentes/métodos , Cobre/química , Anticorpos Imobilizados/imunologia , Ouro/química , Técnicas Biossensoriais/métodos , Nanopartículas Metálicas/química
8.
Biotechnol J ; 19(6): e2400074, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38896409

RESUMO

The ELISA is the most worldwide method for immunoassay. However, the ELISA is losing ground due to low reproducibility of manual experimental processes in both R&D and IVD areas. An automated platform is a good solution, but there are still limitations owning to extremely high cost and requiring large space to set up especially for a small size laboratory. Here, we present a novel all-in-one platform called "VEUS" settable on the laboratory table that offers comprehensive automation of the entire multiplex immunoassay process by exploiting antibody conjugated magnetic particles, quality control and then immunoanalytical reaction, thereby enhancing detection sensitivity and high reproducibility. As a proof of concept, the system exhibits a sensitive LOD of 0.6 and 3.1 pg mL-1 within 1 h run, comparable precision that of molecular diagnostic systems based on PCR method, enabling rapid multiplex diagnosis of Influenza A, Influenza B, and COVID-19 viruses with similar symptoms. Through automation by the all-in-one system, it can be used by novice users, something innovative for immunoassays, relying heavily on user experience. Furthermore, it can contribute to streamline entire immunoassay processes of diverse biomarkers with high reproducibility and convenience in laboratories.


Assuntos
SARS-CoV-2 , Humanos , Imunoensaio/métodos , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química , Reprodutibilidade dos Testes , COVID-19/diagnóstico , COVID-19/virologia , Ensaio de Imunoadsorção Enzimática/métodos , Vírus da Influenza A/imunologia , Vírus da Influenza B/imunologia , Automação Laboratorial/métodos , Limite de Detecção
9.
Commun Biol ; 7(1): 715, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858498

RESUMO

In cryo-electron microscopy (cryo-EM), sample preparation poses a critical bottleneck, particularly for rare or fragile macromolecular assemblies and those suffering from denaturation and particle orientation distribution issues related to air-water interface. In this study, we develop and characterize an immobilized antibody-based affinity grid (IAAG) strategy based on the high-affinity PA tag/NZ-1 antibody epitope tag system. We employ Pyr-NHS as a linker to immobilize NZ-1 Fab on the graphene oxide or carbon-covered grid surface. Our results demonstrate that the IAAG grid effectively enriches PA-tagged target proteins and overcomes preferred orientation issues. Furthermore, we demonstrate the utility of our IAAG strategy for on-grid purification of low-abundance target complexes from cell lysates, enabling atomic resolution cryo-EM. This approach greatly streamlines the purification process, reduces the need for large quantities of biological samples, and addresses common challenges encountered in cryo-EM sample preparation. Collectively, our IAAG strategy provides an efficient and robust means for combined sample purification and vitrification, feasible for high-resolution cryo-EM. This approach holds potential for broader applicability in both cryo-EM and cryo-electron tomography (cryo-ET).


Assuntos
Anticorpos Imobilizados , Microscopia Crioeletrônica , Microscopia Crioeletrônica/métodos , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Grafite/química , Humanos
10.
Biosens Bioelectron ; 259: 116388, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38761744

RESUMO

Claudin18.2 (CLDN18.2) is a tight junction protein often overexpressed in various solid tumors, including gastrointestinal and esophageal cancers, serving as a promising target and potential biomarker for tumor diagnosis, treatment assessment, and prognosis. Despite its significance, no biosensor has been reported to date for the detection of CLDN18.2. Here, we present the inaugural immunosensor for CLDN18.2. In this study, an amine-rich conducting polymer of polymelamine (PM) was electrografted onto different carbon nanomaterial-based screen-printed electrodes (SPEs), including carbon (C), graphene (Gr), graphene oxide (GO), carbon nanotube (CNT), and carbon nanofiber (CNF) via cyclic voltammetry. A comparative study was performed to explore the best material for the preparation of the PM-modified electrodes to be used as in-situ redox substrate for the immunosensor fabrication. The surface chemistry and structural features of pristine and PM-deposited electrodes were analyzed using Raman and scanning electron microscopy (SEM) techniques. Our results showed that the PM deposited on Gr and CNT/SPEs exhibited the most significant and stable redox behavior in PBS buffer. The terminal amine moieties on the PM-modified electrode surfaces were utilized for immobilizing anti-CLDN18.2 monoclonal antibodies via N-ethyl-N'-(3-(dimethylamino)propyl)carbodiimide/N-hydroxysuccinimide chemistry to construct the electrochemical immunosensor platform. Differential pulse voltammetry-based immunosensing of CLDN18.2 protein on BSA/anti-CLDN18.2/PM-Gr/SPE and BSA/anti-CLDN18.2/PM-CNT/SPE exhibited excellent selectivity against other proteins such as CD1, PDCD1, and ErBb2. The limits of detection of these two immunosensor platforms were calculated to be 7.9 pg/mL and 0.104 ng/mL for the CNT and Gr immunosensors, respectively. This study demonstrated that the PM-modified Gr and CNT electrodes offer promising platforms not only for the reagentless signaling but also for covalent immobilization of biomolecules. Moreover, these platforms offer excellent sensitivity and selectivity for the detection of CLDN18.2 due to its enhanced stable redox activity. The immunosensor demonstrated promising results for the sensitive detection of CLDN18.2 in biological samples, addressing the critical need for early gastric cancer diagnosis.


Assuntos
Anticorpos Imobilizados , Técnicas Biossensoriais , Claudinas , Técnicas Eletroquímicas , Eletrodos , Grafite , Nanotubos de Carbono , Técnicas Biossensoriais/métodos , Humanos , Técnicas Eletroquímicas/métodos , Nanotubos de Carbono/química , Imunoensaio/métodos , Anticorpos Imobilizados/química , Grafite/química , Limite de Detecção , Carbono/química , Nanoestruturas/química
11.
Biosens Bioelectron ; 260: 116423, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38810413

RESUMO

Helicobacter pylori (H. pylori) infection is highly prevalent worldwide, affecting more than 43% of world population. The infection can be transmitted through different routes, like oral-oral, fecal-oral, and gastric-oral. Electrochemical sensors play a crucial role in the early detection of various substances, including biomolecules. In this study, the development of nanobody (Nb)-based immunosensor for the detection of H. pylori antigens in saliva samples was investigated. The D2_Nb was isolated and characterized using Western blot and ELISA and employed in the fabrication of the immunosensor. The sensor was prepared using gold screen-printed electrodes, with the immobilization of Nb achieved through chemical linkage using cysteamine-glutaraldehyde. The surface of the electrode was characterized using EIS, FTIR and SEM. Initially, the Nb-based immunosensor's performance was evaluated through cyclic voltammetry (CV), differential pulse voltammetry (DPV), and square wave voltammetry (SWV). The sensor exhibited excellent linearity with an R2 value of 0.96. However, further assessment with the DPV technique revealed both a low limit of detection (5.9 ng/mL, <1 cfu/mL) and high selectivity when exposed to a mixture of similar antigens. Moreover, the immunosensor demonstrated robust recovery rates (96.2%-103.4%) when spiked into artificial saliva and maintained its functionality when stored at room temperature for 24 days.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Infecções por Helicobacter , Helicobacter pylori , Limite de Detecção , Saliva , Anticorpos de Domínio Único , Saliva/microbiologia , Saliva/química , Técnicas Biossensoriais/instrumentação , Helicobacter pylori/imunologia , Helicobacter pylori/isolamento & purificação , Humanos , Anticorpos de Domínio Único/química , Anticorpos de Domínio Único/imunologia , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/microbiologia , Infecções por Helicobacter/imunologia , Imunoensaio/métodos , Ouro/química , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Antígenos de Bactérias/imunologia , Antígenos de Bactérias/análise , Antígenos de Bactérias/isolamento & purificação
12.
ACS Infect Dis ; 10(6): 1949-1957, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38741263

RESUMO

Staphylococcus aureus is an important pathogen that causes nosocomial infections, resulting in unacceptable morbidity and mortality rates. In this work, we proposed the construction of a nanostructured ZnO-based electrochemical immunosensor for qualitative and semiquantitative detection of S. aureus using simple methods for growing zinc oxide nanorods (ZnO NRs) on a sensor board and immobilizing the anti-S. aureus antibody on ZnO NRs through cystamine and glutaraldehyde. The immunosensor detected S. aureus in the 103-107 colony-forming unit (CFU) mL-1 range and showed a limit of detection (LoD) around 0.792 × 103 CFU mL-1. Beyond a satisfactory LoD, the developed immunosensor presented other advantages, such as high versatility for point-of-care assays and a suitable selective factor that admits the detection of the S. aureus concentration range in human hand skin after washing. Moreover, the immunosensor showed the potential to be an excellent device to control nosocomial infection by detecting the presence of S. aureus in human hand skin.


Assuntos
Técnicas Biossensoriais , Infecção Hospitalar , Técnicas Eletroquímicas , Sistemas Automatizados de Assistência Junto ao Leito , Pele , Staphylococcus aureus , Óxido de Zinco , Humanos , Staphylococcus aureus/isolamento & purificação , Infecção Hospitalar/prevenção & controle , Pele/microbiologia , Técnicas Biossensoriais/métodos , Óxido de Zinco/química , Imunoensaio/métodos , Técnicas Eletroquímicas/métodos , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Mãos/microbiologia , Limite de Detecção , Nanotubos/química , Anticorpos Imobilizados/química
13.
Talanta ; 276: 126145, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38723473

RESUMO

Due to the common contamination of multiple mycotoxins in food, which results in stronger toxicity, it is particularly important to simultaneously test for various mycotoxins for the protection of human health. In this study, a disposable immunosensor array with low-cost was designed and fabricated using cellulose paper, polydimethylsiloxane (PDMS), and semiconducting single-walled carbon nanotubes (s-SWCNTs), which was modified with specific antibodies for mycotoxins AFB1 and FB1 detection. The strategy for fabricating the immunosensor array with two individual channels involved a two-step protocol starting with the form of two kinds of carbon films by depositing single-wall carbon nanotubes (SWCNTs) and s-SWCNTs on the cellulose paper as the conductive wire and sensing element, followed by the assembly of chemiresistive biosensor with SWCNTs strip as the wire and s-SWCNTs as the sensing element. After immobilizing AFB1-bovine serum albumin (AFB1-BSA) and FB1-bovine serum albumin (FB1-BSA) separately on the different sensing regions, the formation of mycotoxin-BSA-antibody immunocomplexes transfers to electrochemical signal, which would change with the different concentrations of free mycotoxins. Under optimal conditions, the immunosensor array achieved a limit of detection (LOD) of 0.46 pg/mL for AFB1 and 0.34 pg/mL for FB1 within a wide dynamic range from 1 pg/mL to 20 ng/mL. Furthermore, the AFB1 and FB1 spiked in the ground corn and wheat extracts were detected with satisfactory recoveries, demonstrating the excellent practicality of this established method for simultaneous detection of mycotoxins.


Assuntos
Aflatoxina B1 , Técnicas Biossensoriais , Celulose , Nanotubos de Carbono , Técnicas Biossensoriais/métodos , Celulose/química , Aflatoxina B1/análise , Aflatoxina B1/imunologia , Nanotubos de Carbono/química , Imunoensaio/métodos , Papel , Soroalbumina Bovina/química , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química , Contaminação de Alimentos/análise , Limite de Detecção , Micotoxinas/análise , Micotoxinas/imunologia , Dimetilpolisiloxanos
14.
Anal Chem ; 96(21): 8543-8551, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38748432

RESUMO

In this study, the covalently fixed "end-on" orientation of a monoclonal Listeria monocytogenes antibody (mAb-Lis) to amino terminated oligo (ethylene glycol)-capped gold nanoparticles (NH2-TEG-AuNPs) was used to fabricate an in-house lateral flow strip (LFS), namely, the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS. The aim was to evaluate the performance of the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS in detecting L. monocytogenes. The proposed LFS enabled the sensitive detection of L. monocytogenes in 15 min with a visual limit of detection of 102 CFU/mL. Quantitative analysis indicated an LOD at 10 CFU/mL. The fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS showed no cross-reactivity with other pathogenic bacteria and practical performance across different food matrices, including human blood, milk, and mushroom samples. Furthermore, the clinical performance of the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS for detecting L. monocytogenes was evaluated by using 12 clinical samples validated by the hemoculture method. It demonstrated excellent concordance with the reference methods, with no false-positive or false-negative results observed. Therefore, the fixed "end-on" Lis-mAb-NH-TEG-AuNPs LFS serves as a promising candidate for a point-of-care test (POCT), enabling the rapid, precise, and highly sensitive detection of L. monocytogenes in clinical samples and contaminated food.


Assuntos
Anticorpos Monoclonais , Ouro , Listeria monocytogenes , Nanopartículas Metálicas , Listeria monocytogenes/isolamento & purificação , Listeria monocytogenes/imunologia , Ouro/química , Nanopartículas Metálicas/química , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/química , Humanos , Limite de Detecção , Microbiologia de Alimentos , Leite/microbiologia , Leite/química , Anticorpos Antibacterianos/química , Anticorpos Antibacterianos/imunologia , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , Animais , Listeriose/microbiologia , Listeriose/diagnóstico
15.
Anal Chim Acta ; 1306: 342617, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692789

RESUMO

BACKGROUND: Alpha-fetoprotein (AFP) is a fetal protein that can indicate congenital anomalies such as Down syndrome and spinal canal blockage when detected at abnormal levels in pregnant women. Current AFP detection methods rely on invasive blood or serum samples, which require sophisticated equipment. From the many solutions proposed, colorimetric paper-based assays excel in point-of-care settings. The concept of paper-based ELISA (p-ELISA) enhances traditional methods, aligning with the ASSURED criteria for diagnostics in resource-limited regions. Despite success in microfluidic paper-based assay devices, laser printing remains underexplored for p-ELISA. Additionally, modifying the paper surface provides an additional layer of sensitivity enhancement. RESULTS: In this study, we developed a novel laser-printed paper-based ELISA (LP-pELISA) for rapid, sensitive, and noninvasive detection of AFP in saliva samples. The LP-pELISA platform was fabricated by printing hydrophobic barriers on filter paper using a laser printer, followed by depositing hydroxyapatite (HAp) as an immobilization material for the antibodies. The colorimetric detection was achieved using AuNPs functionalized with anti-AFP antibodies and silver nitrate enhancement. The LP-pELISA exhibited a linear response for AFP detection in both buffer and saliva samples over a range of 1.0-800 ng mL-1, with a limit of detection (LOD) reaching 1.0 ng mL-1. The assay also demonstrated good selectivity, repeatability, reproducibility, and stability. The LP-pELISA was further validated by testing spiked human saliva samples, showing its potential for point-of-care diagnosis of congenital disabilities. SIGNIFICANCE: The LP-pELISA is a noninvasive platform showcasing simplicity, cost-effectiveness, and user-friendliness, utilizing laser printing, hydroxyapatite modification, and saliva samples to efficiently detect AFP. Beyond its application for AFP, this method's versatility extends to other biomarkers, positioning it as a catalyst for the evolution of paper-based biosensors. The LP-pELISA holds promise as a transformative tool for point-of-care diagnostics, fostering advancements in healthcare with its innovative technology.


Assuntos
Colorimetria , Durapatita , Ensaio de Imunoadsorção Enzimática , Lasers , Papel , Saliva , alfa-Fetoproteínas , Humanos , Saliva/química , Durapatita/química , alfa-Fetoproteínas/análise , Impressão , Ouro/química , Limite de Detecção , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
16.
Biosens Bioelectron ; 258: 116376, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38739999

RESUMO

The capacitive immunosensor, known for its label-free simplicity, has great potential for point-of-care diagnostics. However, the interaction between insulation and recognition layers on the sensing electrode greatly affects its performance. This study introduces a pioneering dual-layer strategy, implementing a novel combination of acrylic resin (AR) and nitrocellulose (NC) coatings on screen-printed carbon electrodes (SPCEs). This innovative approach not only enhances the dielectric properties of the capacitive sensor but also streamlines the immobilization of recognizing elements. Particularly noteworthy is the superior reliability and insulation offered by the AR coating, surpassing the limitations of traditional self-assembled monolayer (SAM) modifications. This dual-layer methodology establishes a robust foundation for constructing capacitive sensors optimized specifically for liquid medium-based biosensing applications. The NC coating in this study represents a breakthrough in effectively immobilizing BSA, unraveling the capacitive response intricately linked to the quantity of adsorbed recognizing elements. The results underscore the prowess of the proposed immunosensor, showcasing a meticulously defined linear calibration curve for anti-BSA (ranging from 0 to 25 µg/ml). Additionally, specific interactions with anti-HAS and anti-TNF-α further validate the versatility and efficacy of the developed immunosensor. This work presents a streamlined and highly efficient protocol for developing label-free immunosensors for antibody determination and introduces a paradigm shift by utilizing readily available electrodes and sensing systems. The findings are poised to catalyze a significant acceleration in the advancement of biosensor technology, opening new avenues for innovative applications in point-of-care diagnostics.


Assuntos
Resinas Acrílicas , Técnicas Biossensoriais , Carbono , Colódio , Eletrodos , Soroalbumina Bovina , Técnicas Biossensoriais/instrumentação , Carbono/química , Resinas Acrílicas/química , Imunoensaio/instrumentação , Imunoensaio/métodos , Colódio/química , Soroalbumina Bovina/química , Humanos , Capacitância Elétrica , Limite de Detecção , Técnicas Eletroquímicas/métodos , Anticorpos Imobilizados/química , Animais
17.
Anal Chem ; 96(21): 8837-8843, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38757510

RESUMO

Breast cancer poses the significance of early diagnosis and treatment. Here, we developed an innovative photoelectrochemical (PEC) immunosensor characterized by high-level dual photocurrent signals and exceptional sensitivity. The PEC sensor, denoted as MIL&Ag2S, was constructed by incorporating Ag2S into a metal-organic framework of MIL-101(Cr). This composite not only enhanced electron-hole separation and conductivity but also yielded robust and stable dual photocurrent signals. Through the implementation of signal switching, we achieved the combined detection of cancer antigen 15-3 (CA15-3) and carcinoembryonic antigen (CEA) with outstanding stability, reproducibility, and specificity. The results revealed a linear range for CEA detection spanning 0.01-32 ng/mL, with a remarkably low detection limit of 0.0023 ng/mL. Similarly, for CA15-3 detection, the linear range extended from 0.1 to 320 U/mL, with a low detection limit of 0.014 U/mL. The proposed strategy introduces new avenues for the development of highly efficient, cost-effective, and user-friendly PEC sensors. Furthermore, it holds promising prospects for early clinical diagnosis, contributing to potential breakthroughs in medical detection and ultimately improving patient outcomes.


Assuntos
Biomarcadores Tumorais , Neoplasias da Mama , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Estruturas Metalorgânicas , Mucina-1 , Compostos de Prata , Estruturas Metalorgânicas/química , Humanos , Neoplasias da Mama/diagnóstico , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Mucina-1/análise , Mucina-1/sangue , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/análise , Compostos de Prata/química , Imunoensaio/métodos , Técnicas Biossensoriais , Feminino , Limite de Detecção , Processos Fotoquímicos , Anticorpos Imobilizados/imunologia , Anticorpos Imobilizados/química
18.
J Hazard Mater ; 472: 134321, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38723478

RESUMO

It is challenging to prepare sample pretreatment materials with simple use, strong selectivity and satisfactory enrichment performance. In this study, the antibody (3D4) that can specifically recognize zearalenone (ZEN) and its metabolites was immobilized on the surface of gold-coated magnetic Fe3O4 nanoparticles (GMN) by streptavidin (SA)-biotin interaction using GMN as the substrate and our designed four-arm PEG derivative (HS-4ARMPEG10K-(CM)3) as the linker. The immunomagnetic nanoparticles (GMN-4ARMPEG10K-SA-3D4) prepared by this strategy can achieve rapid enrichment (only 5 min) of analytes directly in the matrix, and higher enrichment capacity compared with the previous immunomagnetic particles. The sensitive and accurate analysis of ZEN and its metabolites can be achieved coupled with HPLC-MS/MS. The LODs and LOQs were 0.02-0.05 µg/kg and 0.05-0.10 µg/kg, respectively. The recoveries were 84.13%-112.67%, and the RSDs were 1.09%-9.39%. The method can provide a powerful tool for highly sensitive and rapid monitoring of mycotoxins in complex matrices due to its' strong selectivity and resistance to matrix interference.


Assuntos
Polietilenoglicóis , Zearalenona , Zearalenona/química , Zearalenona/análise , Zearalenona/metabolismo , Polietilenoglicóis/química , Ouro/química , Separação Imunomagnética , Nanopartículas de Magnetita/química , Limite de Detecção , Anticorpos Imobilizados/química , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem
19.
Biosens Bioelectron ; 258: 116349, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38705072

RESUMO

Detection of cancer-related exosomes in body fluids has become a revolutionary strategy for early cancer diagnosis and prognosis prediction. We have developed a two-step targeting detection method, termed PS-MIPs-NELISA SERS, for rapid and highly sensitive exosomes detection. In the first step, a phospholipid polar site imprinting strategy was employed using magnetic PS-MIPs (phospholipids-molecularly imprinted polymers) to selectively isolate and enrich all exosomes from urine samples. In the second step, a nanozyme-linked immunosorbent assay (NELISA) technique was utilized. We constructed Au/Na7PMo11O39 nanoparticles (NPs) with both surface-enhanced Raman scattering (SERS) property and peroxidase catalytic activity, followed by the immobilization of CD9 antibodies on the surface of Au/Na7PMo11O39 NPs. The Au/Na7PMo11O39-CD9 antibody complexes were then used to recognize CD9 proteins on the surface of exosomes enriched by magnetic PS-MIPs. Lastly, the high sensitivity detection of exosomes was achieved indirectly via the SERS activity and peroxidase-like activity of Au/Na7PMo11O39 NPs. The quantity of exosomes in urine samples from pancreatic cancer patients obtained by the PS-MIPs-NELISA SERS technique showed a linear relationship with the SERS intensity in the range of 6.21 × 107-2.81 × 108 particles/mL, with a limit of detection (LOD) of 5.82 × 107 particles/mL. The SERS signal intensity of exosomes in urine samples from pancreatic cancer patients was higher than that of healthy volunteers. This bidirectional MIPs-NELISA-SERS approach enables noninvasive, highly sensitive, and rapid detection of cancer, facilitating the monitoring of disease progression during treatment and opening up a new avenue for rapid early cancer screening.


Assuntos
Técnicas Biossensoriais , Exossomos , Ouro , Análise Espectral Raman , Humanos , Exossomos/química , Ouro/química , Análise Espectral Raman/métodos , Fosfolipídeos/química , Fosfolipídeos/urina , Limite de Detecção , Impressão Molecular , Polímeros Molecularmente Impressos/química , Epitopos/imunologia , Epitopos/química , Nanopartículas Metálicas/química , Tetraspanina 29/urina , Tetraspanina 29/análise , Anticorpos Imobilizados/química
20.
Anal Sci ; 40(7): 1357-1363, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38662337

RESUMO

The level of interleukin-8 (IL-8) in the body is an effective factor for the early diagnosis of acute tubular necrosis and oral tumor. In this work, a novel sandwich-like voltametric immunosensor (SVS) of IL-8 was constructed by preparing ß-cyclodextrin/carbon nanotube (CD/CNT) to immobilize primary antibody (PAb) of IL-8 and UIO-66-NH2 MOFs structure to immobilize second antibody (SAb) and methylene blue (Mb) probe. In this designed SVS, the prepared CD/CNT nanohybrid with large surface area and conductivity can immobilize PAb via simple host-guest recognition, and UIO-66-NH2 provided an ideal platform to accommodate SAb and a large number of Mb molecules as signal-amplifier. In the existence of target IL-8, the current peak of Mb from the SVS assay increases with the increasement of IL-8 level. Through optimizing and adjusting various factors, a wide linearity (0.001-2.5 ng mL-1) and low analytical limit (0.2 pg mL-1) of IL-8 were realized, so it's expected the developed SVS strategy has significant applications for the detection of IL-8.


Assuntos
Técnicas Biossensoriais , Interleucina-8 , Nanotubos de Carbono , beta-Ciclodextrinas , Nanotubos de Carbono/química , Interleucina-8/análise , beta-Ciclodextrinas/química , Imunoensaio/métodos , Humanos , Estruturas Metalorgânicas/química , Limite de Detecção , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA