Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.568
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Jt Dis Relat Surg ; 35(2): 285-292, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727106

RESUMO

OBJECTIVES: The study aimed to investigate the factors associated with shoulder stiffness following open reduction and internal fixation (ORIF) of proximal humeral fractures. PATIENTS AND METHODS: The retrospective study included a total of 151 patients who underwent ORIF of proximal humeral fractures between January 2016 and May 2021. Based on their shoulder joint motion at the latest follow-up, the patients were divided into two groups. The stiffness group (n=32; 8 males, 24 females; mean age: 62.4±9.3 years; range, 31 to 79 years), exhibited restricted shoulder forward flexion (<120°), limited arm lateral external rotation (<30°), and reduced back internal rotation below the L3 level. The remaining patients were included in the non-stiffness group (n=119; 52 males, 67 females; mean age: 56.4±13.4 years; range, 18 to 90 years). Various factors were examined to evaluate the association with shoulder stiffness following ORIF of proximal humeral fractures by multivariate unconditional logistic regression models. RESULTS: The mean follow-up duration was 31.8±12.6 (range, 12 to 68) months. Based on the results of the multivariate regression analysis, it was found that high-energy injuries [compared to low-energy injuries; adjusted odds ratio (aOR)=7.706, 95% confidence interval (CI): 3.564-15.579, p<0.001], a time from injury to surgery longer than one week (compared to a time from injury to surgery equal to or less than one week; aOR=5.275, 95% CI: 1.7321-9.472, p=0.031), and a body mass index (BMI) >24.0 kg/m2 (compared to a BMI between 18.5 and 24.0 kg/m2 ; aOR=4.427, 95% CI: 1.671-11.722, p=0.023) were identified as risk factors for shoulder stiffness following ORIF of proximal humeral fractures. CONCLUSION: High-energy injury, time from injury to surgery longer than one week, and BMI >24.0 kg/m2 were identified as independent risk factors for shoulder stiffness after proximal humeral fracture surgery, which should be treated with caution in clinical treatment.


Assuntos
Fixação Interna de Fraturas , Redução Aberta , Amplitude de Movimento Articular , Fraturas do Ombro , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Ombro/cirurgia , Feminino , Idoso , Estudos Retrospectivos , Adulto , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Redução Aberta/métodos , Redução Aberta/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Idoso de 80 Anos ou mais , Fatores de Risco , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Adulto Jovem
2.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
3.
J Orthop Surg (Hong Kong) ; 32(2): 10225536241257169, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38769768

RESUMO

Background: The purpose of this study was to investigate the effect of 3D-printed technology to repair glenoid bone defect on shoulder joint stability. Methods: The shoulder joints of 25 male cadavers were tested. The 3D-printed glenoid pad was designed and fabricated. The specimens were divided into 5 groups. Group A: no bone defect and the structure of the glenoid labrum and joint capsule was intact; Group B: Anterior inferior bone defect of the shoulder glenoid; Group C: a pad with a width of 2 mm was installed; Group D: a pad with a width of 4 mm was installed; Group E: a pad with a width of 6 mm was installed. This study measured the distance the humeral head moved forward at the time of glenohumeral dislocation and the maximum load required to dislocate the shoulder. Results: The shoulder joint stability and humerus displacement was significantly lower in groups B and C compared with group A (p < .05). Compared with group A, the stability of the shoulder joint of group D was significantly improved (p < .05). However, there was no significant difference in humerus displacement between groups D and A (p > .05). In addition, compared with group A, shoulder joint stability was significantly increased and humerus displacement was significantly decreased in group E (p < .05). Conclusion: The 3D-printed technology can be used to make the shoulder glenoid pad to perfectly restore the geometric shape of the shoulder glenoid articular surface. Moreover, the 3D-printed pad is 2 mm larger than the normal glenoid width to restore the initial stability of the shoulder joint.


Assuntos
Ligas , Cadáver , Impressão Tridimensional , Articulação do Ombro , Titânio , Humanos , Masculino , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Fenômenos Biomecânicos , Instabilidade Articular/cirurgia , Instabilidade Articular/fisiopatologia , Cavidade Glenoide/cirurgia , Desenho de Prótese
4.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739663

RESUMO

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Fenômenos Biomecânicos , Tenotomia/métodos , Recuperação de Função Fisiológica , Tendões/cirurgia , Amplitude de Movimento Articular
5.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
6.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562643

RESUMO

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Assuntos
Artroplastia do Ombro , Fraturas Periprotéticas , Articulação do Ombro , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento , Fraturas Periprotéticas/etiologia , Escápula , Estudos Retrospectivos , Amplitude de Movimento Articular , Reoperação/efeitos adversos
7.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619382

RESUMO

¼ Posterior glenohumeral instability is relatively uncommon compared with anterior instability, but is becoming an increasingly recognized and surgically managed shoulder pathology.¼ Soft-tissue stabilization alone may not be sufficient in patients who present with substantial bone loss to the posterior glenoid and/or the anterior humeral head.¼ For posterior glenoid defects, posterior glenoid osteoarticular augmentation can be used, and posterior glenoid opening wedge osteotomy can be considered in cases of posterior instability with pathologic retroversion.¼ For humeral head lesions, several surgical treatment options are available including subscapularis transposition into the humeral head defect, autograft or allograft reconstruction, humeral rotation osteotomy, and shoulder arthroplasty.


Assuntos
Instabilidade Articular , Articulação do Ombro , Humanos , Ombro , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Escápula , Cabeça do Úmero/cirurgia
9.
BMJ ; 385: e077939, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688550

RESUMO

OBJECTIVES: To answer a national research priority by comparing the risk-benefit and costs associated with reverse total shoulder replacement (RTSR) and anatomical total shoulder replacement (TSR) in patients having elective primary shoulder replacement for osteoarthritis. DESIGN: Population based cohort study using data from the National Joint Registry and Hospital Episode Statistics for England. SETTING: Public hospitals and publicly funded procedures at private hospitals in England, 2012-20. PARTICIPANTS: Adults aged 60 years or older who underwent RTSR or TSR for osteoarthritis with intact rotator cuff tendons. Patients were identified from the National Joint Registry and linked to NHS Hospital Episode Statistics and civil registration mortality data. Propensity score matching and inverse probability of treatment weighting were used to balance the study groups. MAIN OUTCOME MEASURES: The main outcome measure was revision surgery. Secondary outcome measures included serious adverse events within 90 days, reoperations within 12 months, prolonged hospital stay (more than three nights), change in Oxford Shoulder Score (preoperative to six month postoperative), and lifetime costs to the healthcare service. RESULTS: The propensity score matched population comprised 7124 RTSR or TSR procedures (126 were revised), and the inverse probability of treatment weighted population comprised 12 968 procedures (294 were revised) with a maximum follow-up of 8.75 years. RTSR had a reduced hazard ratio of revision in the first three years (hazard ratio local minimum 0.33, 95% confidence interval 0.18 to 0.59) with no clinically important difference in revision-free restricted mean survival time, and a reduced relative risk of reoperations at 12 months (odds ratio 0.45, 95% confidence interval 0.25 to 0.83) with an absolute risk difference of -0.51% (95% confidence interval -0.89 to -0.13). Serious adverse events and prolonged hospital stay risks, change in Oxford Shoulder Score, and modelled mean lifetime costs were similar. Outcomes remained consistent after weighting. CONCLUSIONS: This study's findings provide reassurance that RTSR is an acceptable alternative to TSR for patients aged 60 years or older with osteoarthritis and intact rotator cuff tendons. Despite a significant difference in the risk profiles of revision surgery over time, no statistically significant and clinically important differences between RTSR and TSR were found in terms of long term revision surgery, serious adverse events, reoperations, prolonged hospital stay, or lifetime healthcare costs.


Assuntos
Artroplastia do Ombro , Osteoartrite , Sistema de Registros , Reoperação , Humanos , Inglaterra/epidemiologia , Osteoartrite/cirurgia , Masculino , Feminino , Artroplastia do Ombro/efeitos adversos , Idoso , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Pontuação de Propensão , Estudos de Coortes , Tempo de Internação/estatística & dados numéricos , Resultado do Tratamento , Análise Custo-Benefício , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia
10.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653836

RESUMO

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Idoso de 80 Anos ou mais , Feminino , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Radiografia , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem
11.
Arch Orthop Trauma Surg ; 144(5): 2047-2055, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38630250

RESUMO

INTRODUCTION: The aim of this study was to estimate the incidence of stiffness during the first 6 months after rotator cuff repair and to evaluate postoperative stiffness with respect to its risk factors and its influence on the outcome at 6 months postoperatively. METHODS: In a prospective cohort of 117 patients (69 women, 48 men; average age 59) from our institutional rotator cuff registry, who underwent either arthroscopic (n = 77) or open (n = 40) rotator cuff repair, we measured shoulder range of motion (ROM) at 3 and 6 months post-surgery. We evaluated the incidence of stiffness and analyzed functional outcomes, comparing various preoperative and intraoperative factors in patients with stiffness to those without at the 6-month mark. RESULTS: Shoulder stiffness was observed in 31% of patients (36/117) at 3 months postoperatively, decreasing to 20% (23/117) at 6 months. No significant link was found between stiffness at 6 months and demographic factors, preoperative stiffness, tear characteristics, or the type of repair. Notably, patients undergoing arthroscopic repair exhibited a 4.3-fold higher risk (OR 4.3; 95% CI 1.2-15.6, p = 0.02) of developing stiffness at 6 months compared to those with mini-open repair. Despite these differences in stiffness rates, no significant variation was seen in the American Shoulder and Elbow Surgeons (ASES) score, Single Assessment Numeric Evaluation (SANE) score, or Visual Analog Scale (VAS) scores at 6 months between the groups. CONCLUSION: The incidence of postoperative shoulder stiffness following rotator cuff repair was substantial at 31% at 3 months, reducing to 20% by 6 months. Mini-open repair was associated with a lower 6-month stiffness incidence than arthroscopic repair, likely due to variations in rehabilitation protocols. However, the presence of stiffness at 6 months post-surgery did not significantly affect functional outcomes or pain levels.


Assuntos
Artroscopia , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Artroscopia/efeitos adversos , Fatores de Risco , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/epidemiologia , Incidência , Estudos Prospectivos , Idoso , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Manguito Rotador/cirurgia , Adulto
12.
J Orthop Surg Res ; 19(1): 222, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576016

RESUMO

BACKGROUND: To compare the histopathological results of biceps tenodesis (BT) performed with normal, low, and high pressures for superior capsule reconstruction (SCR) in rabbits with massive rotator cuff tears. MATERIALS AND METHODS: Thirty rabbits were divided into three groups. Rabbits 1-10 underwent SCR with BT at the same pressure (Group 1), value measured in the groove; 50% lower (Group 2); 50% higher (Group 3). After the 4-week follow-up, shoulder were en-bloc excised and histopathological evaluation was performed with modified Bonar's scale. Results were compared between the groups, statistically. RESULTS: Extracellular matrix were significantly lower in group 2 compared to the other groups (p < 0.05). Cellularity levels were significantly lower in group 2 compared to the other groups (p < 0.05). Group 2 had no difference between the sides (p > 0.05). Group 2 had lower vascularity levels compared to the other groups (p = 0.01). DICSUSSION: When the biceps tendon was in the bicipital groove and in a more mobile state with lower pressure exposure. BT performed with a tension that creates less pressure than the biceps in the groove is more successful in SCR.


Assuntos
Lesões do Manguito Rotador , Articulação do Ombro , Tenodese , Coelhos , Animais , Tenodese/métodos , Músculo Esquelético/cirurgia , Lesões do Manguito Rotador/cirurgia , Lesões do Manguito Rotador/patologia , Tendões/cirurgia , Tendões/patologia , Braço/cirurgia , Articulação do Ombro/cirurgia , Artroscopia/métodos
13.
Am J Sports Med ; 52(6): 1472-1482, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38590203

RESUMO

BACKGROUND: Glenoid reconstruction with a bone block for anterior glenoid bone loss (GBL) has shown excellent outcomes. However, fixation techniques that require metal implants are associated with metal-related complications and bone graft resorption. HYPOTHESIS: Arthroscopic glenoid reconstruction using a tricortical iliac crest bone graft (ICBG) and metal-free suture tape cerclage fixation can safely and effectively restore the glenoid surface area in patients with recurrent anterior shoulder instability and anterior GBL. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Adult patients (≥18 years) of both sexes with recurrent anterior shoulder instability and anterior GBL ≥15% were enrolled. These patients underwent arthroscopic glenoid reconstruction with ICBGs and metal-free suture tape cerclage fixation. The effectiveness and clinical outcomes with this technique were evaluated at 24 months using functional scores. Resorption of the graft articular surface was assessed by computed tomography, with the graft surface divided into 6 square areas aligned in 2 columns. Descriptive analysis was conducted. RESULTS: A total of 23 consecutive patients met inclusion criteria (22 male, 1 female; mean age, 30.5 ± 7.9 years). The mean preoperative GBL was 19.7% ± 3.4%, and there were 15 allograft and 8 autograft ICBGs. All patients exhibited graft union at 3 months. The median follow-up was 38.5 months (interquartile range, 24-45 months). The Western Ontario Shoulder Instability Index, Rowe, Constant-Murley, and Subjective Shoulder Value scores improved from preoperatively (35.1%, 24.8, 83.1, and 30.9, respectively) to postoperatively (84.7%, 91.1, 96.0, and 90.9, respectively) (P < .001). No differences in clinical scores were observed between the graft types. One surgical wound infection was reported, and 2 patients (8.7% [95% CI, 2.4%-26.8%]) required a reoperation. The mean overall glenoid surface area increased from 80.3% ± 3.5% to 117.0% ± 8.3% immediately after surgery before subsequently reducing to 98.7% ± 6.2% and 95.0% ± 5.7% at 12 and 24 months, respectively (P < .001). The mean graft resorption rate was 18.1% ± 7.9% in the inner column and 80.3% ± 22.4% in the outer column. Additionally, 3 patients treated with an allograft (20.0% [95% CI, 7.1%-45.2%]), including the 2 with clinical failures, exhibited complete graft resorption at the last follow-up. CONCLUSION: Arthroscopic glenoid reconstruction using an ICBG and metal-free suture tape cerclage fixation was safe and effective, yielding excellent clinical outcomes. Resorption of the graft articular surface predominantly affected the nonloaded areas beyond the best-fit circle perimeter.


Assuntos
Artroscopia , Transplante Ósseo , Instabilidade Articular , Articulação do Ombro , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Adulto , Instabilidade Articular/cirurgia , Transplante Ósseo/métodos , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Artroscopia/métodos , Adulto Jovem , Recidiva , Reabsorção Óssea/cirurgia , Reabsorção Óssea/diagnóstico por imagem , Ílio/transplante , Ílio/cirurgia , Resultado do Tratamento
14.
Am J Sports Med ; 52(6): 1464-1471, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38590171

RESUMO

BACKGROUND: Given the variability across populations and settings, defining the MCID and the PASS for the Rowe and ASOSS scores and patients undergoing primary and revision Latarjet it is essential to have accurate benchmarks relevant to these groups when interpreting clinical results. PURPOSE: To determine the minimal clinically important difference (MCID) and Patient Acceptable Symptom State (PASS) thresholds for the visual analog scale (VAS) for pain during sports, Athletic Shoulder Outcome Scoring System (ASOSS), and Rowe scores after primary and revision Latarjet procedures for treatment of shoulder instability. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 3. METHODS: Between January 2018 and January 2020, a retrospective review of 149 patients undergoing primary Latarjet (n = 82) and revision Latarjet (n = 67) to treat shoulder instability was performed in a single institution. Patient-reported outcome measures were collected preoperatively and 1 year postoperatively. The delta was defined as the change between the pre- and postoperative scores. Distribution-based and anchored-based approaches were used to estimate the MCID and the PASS, respectively. The optimal cutoff point and the percentage of patients achieving those thresholds were also calculated. RESULTS: The distribution-based MCIDs after primary Latarjet were 1.1, 7.5, and 9.6 for the VAS, Rowe, and ASOSS scores, respectively. The rates of patients who achieved the MCID thresholds were 93.9%, 98.7%, and 100% for the VAS, Rowe, and ASOSS scores, respectively. The PASS thresholds after primary Latarjet were ≤1, ≥90, and ≥85 for the VAS, Rowe, and ASOSS scores, respectively. The percentages of patients who achieved PASS thresholds were 82.9%, 89%, and 86.5% for the VAS, Rowe, and ASOSS scores, respectively. The distribution-based MCIDs after revision Latarjet were 0.6, 6.2, and 3.4 for the VAS, Rowe, and ASOSS scores, respectively. The rates of patients who achieved MCID thresholds were 89.3%, 100%, and 100% for the VAS, Rowe, and ASOSS scores, respectively. The PASS thresholds were ≤3, ≥87, and ≥86 after revision Latarjet for the VAS, Rowe, and ASOSS scores, respectively. The rates of patients who achieved the PASS thresholds were 88%, 88%, and 91% for the VAS, Rowe, and ASOSS, respectively. CONCLUSION: This study identified useful values for the MCID and PASS thresholds in VAS, Rowe, and ASOSS scores after primary and revision Latarjet procedures for treating shoulder instability. Most patients achieved MCID and PASS benchmarks, indicating successful primary and revision Latarjet procedure outcomes. These metrics can serve as valuable parameters when analyzing parameters in future studies and have the potential to enhance patient care by optimizing treatment strategies and surgical decision making.


Assuntos
Instabilidade Articular , Diferença Mínima Clinicamente Importante , Medidas de Resultados Relatados pelo Paciente , Humanos , Estudos Retrospectivos , Masculino , Feminino , Adulto , Instabilidade Articular/cirurgia , Reoperação/estatística & dados numéricos , Adulto Jovem , Adolescente , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Medição da Dor , Relevância Clínica
15.
Am J Sports Med ; 52(6): 1411-1418, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38616551

RESUMO

BACKGROUND: Despite advancements in surgical technique, failure of tendon healing remains a common problem after arthroscopic rotator cuff repair (ARCR). PURPOSE/HYPOTHESIS: The purpose of this study was to examine the relationship between range of motion (ROM) recovery and healing after ARCR. It was hypothesized that an early loss of ROM would be associated with tendon healing. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: This was a retrospective comparative study of primary ARCR of isolated full-thickness supraspinatus (SSN) tendon tears. Cases were retrieved from a prospective rotator cuff repair database and divided into 2 groups based on healing (healed/nonhealed). A standardized clinical evaluation was performed before and at 6 weeks, 3 months, and 6 months after surgery. Collected data included passive and active ROM, visual analog scale for pain, and Constant score. Healing was assessed by ultrasound at 6 months. RESULTS: Of 1397 eligible ARCRs, 1207 were included. The healing rate was 86.7%. Age was higher in the nonhealed group (57.8 ± 7.9 years vs 61.6 ± 8.8 years; P < .001). Patients with healed repairs had a larger decrease in passive anterior elevation (AE) from the preoperative to the 6-week postoperative visit (-31°± 28° vs -18°± 26°; P < .001), followed by a more substantial increase throughout the remaining follow-up period (32°± 23° vs 18°± 21°; P < .001). At 6 months postoperatively, there was no difference in AE between groups (159°± 17° vs 161°± 14°; P > .999). External rotation elbow at side (ER1) and internal rotation hand in the back (IR1) followed similar courses of recovery. Passive and active ROM had a strong positive correlation at each follow-up. Age (odds ratio [OR], 1.79; 95% CI, 1.45-2.23; P < .001) and 6-week passive AE (OR, 1.33; 95% CI, 1.20-1.48; P < .001) and ER1 (OR, 1.15; 95% CI, 1.03-1.29; P = .017) were predictors for nonhealing. CONCLUSION: Lower passive AE and ER1 at 6 weeks postoperatively and younger age are associated with healing after ARCR of isolated SSN tendon tears. At 6 months postoperatively, there were no differences in ROM, regardless of tendon healing.


Assuntos
Artroscopia , Amplitude de Movimento Articular , Lesões do Manguito Rotador , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Masculino , Lesões do Manguito Rotador/cirurgia , Estudos de Casos e Controles , Idoso , Cicatrização , Manguito Rotador/cirurgia , Rotação , Recuperação de Função Fisiológica , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia
16.
Am J Sports Med ; 52(6): 1457-1463, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38616609

RESUMO

BACKGROUND: The use of isolated soft tissue repair versus bone block stabilization for the treatment of recurrent anterior shoulder instability in adolescents has no scientific evidence. PURPOSE: To compare the clinical outcomes of adolescent patients who underwent isolated arthroscopic Bankart (iB) repair with those who underwent the arthroscopic Bristow-Latarjet procedure in addition to Bankart (BLB) repair. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 60 shoulders in adolescents (aged 13-18 years) were reviewed with a minimum 2 years' follow-up: iB repair (n = 36) and arthroscopic Bankart repair with an additional Bristow-Latarjet procedure (BLB; n = 24). The characteristics of the patients in each group in terms of age at the first instability episode, age at surgery, hyperlaxity, participation in at-risk sports, and Instability Severity Index Score were comparable. The mean follow-up was longer in the iB group (7.7 vs 4.1 years, respectively), whereas the rates of patients engaged in competition and those with glenoid lesions were higher in the BLB group. The primary outcome measures were failure, defined as the recurrence of instability (clinical dislocation or subluxation), and return to sports. The mean follow-up was 6.2 years (range, 2-16 years). RESULTS: At the last follow-up, the rate of recurrence was significantly higher in the iB group, with 22% (8/36) failures, than in the BLB group, with 8% (2/24) instability recurrences (P < .05). The rate of return to sports at the same level was significantly higher after the BLB repair than after iB repair (79% vs 47%, respectively; P < .001). No statistical difference was found in patient-reported outcome scores between treatment groups (P > .05). Although failures occurred early after the BLB repair, 88% of failures after iB repair occurred after 2 years. On multivariate analysis, adolescents in the iB group with >3 episodes of preoperative dislocation and shoulder hyperlaxity (external rotation >90°) had a 60% recurrence rate (P < .005). CONCLUSION: Adolescent patients undergoing the BLB repair had a lower rate of recurrent instability and higher rates of return to sports and competition than those undergoing iB repair. Patients with shoulder hyperlaxity (external rotation >90°) and >3 dislocations had an unacceptable failure rate of 60% after iB repair.


Assuntos
Artroscopia , Instabilidade Articular , Recidiva , Volta ao Esporte , Articulação do Ombro , Humanos , Adolescente , Artroscopia/métodos , Feminino , Masculino , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Luxação do Ombro/cirurgia , Lesões de Bankart/cirurgia
17.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
18.
Eur J Orthop Surg Traumatol ; 34(4): 2137-2145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38557891

RESUMO

PURPOSE: When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality. METHODS: RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem. RESULTS: The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05). CONCLUSION: The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.


Assuntos
Artroplastia do Ombro , Úmero , Desenho de Prótese , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Idoso , Úmero/cirurgia , Úmero/diagnóstico por imagem , Masculino , Feminino , Prótese de Ombro/efeitos adversos , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Estudos Retrospectivos
19.
Eur J Orthop Surg Traumatol ; 34(4): 2193-2200, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38578440

RESUMO

INTRODUCTION: Revision shoulder arthroplasty can be challenging. One of the main considerations for surgeons is the type of implant that was placed in the initial surgery. Anatomic shoulder arthroplasty (ASA) is used for cases of osteoarthritis as well as for fractures of the humeral head. Hemiarthroplasty can be used for complex proximal humerus fractures. The purpose of this study is to determine whether there is a difference in clinical and radiographic outcomes between patients that failed primary fracture hemiarthroplasty (FHA), or ASA for osteoarthritis and then required reoperation with a conversion to reverse shoulder arthroplasty (RSA). METHODS: Patients with failed anatomic shoulder replacement, who had undergone conversion to RSA, were enrolled after a mean follow-up of 107 (85-157) months. Two different groups, one with failed ASA implanted for osteoarthritis and one with failed FHA, were created. At follow-up patients were assessed with standard radiographs and clinical outcome scores. RESULTS: Twenty-nine patients (f = 17, m = 12; 51%) suffered from a failed ASA (Group A), while the remaining 28 patients (f = 21, m = 74; 49%) had been revised due to a failed FHA (Group B). Patients of Group B had a poorer Constant score (Group A: 60 vs. Group B: 46; p = 0.02). Abduction (Group A: 115° vs. Group B: 89°; p = 0.02) was worse after conversion of a failed FHA to RSA in comparison to conversions of failed ASA. The mean bone loss of the lateral metaphysis was higher in patients with failed FHA (Group A: 5 mm vs. Group B: 20 mm; p = 0.0). CONCLUSION: The initial indication for anatomic shoulder arthroplasty influences the clinical and radiological outcome after conversion to RSA. Conversion of failed FHA to RSA is related to an increased metaphyseal bone loss, decreased range of motion and poorer clinical outcomes when compared to conversions of failed ASA implanted for osteoarthritis. LEVEL OF EVIDENCE: III Retrospective Cohort Comparison Study.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Osteoartrite , Radiografia , Reoperação , Fraturas do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Hemiartroplastia/métodos , Masculino , Feminino , Idoso , Reoperação/estatística & dados numéricos , Reoperação/métodos , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Amplitude de Movimento Articular , Seguimentos , Estudos Retrospectivos
20.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574183

RESUMO

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Manguito Rotador/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA