Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
Orthop Clin North Am ; 55(4): 503-512, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39216955

RESUMO

Total ankle replacement (TAR) is an effective operative treatment of end-stage ankle osteoarthritis (OA) in the appropriate patient, conferring improved kinematic function, decreased stress across adjacent joints, and offering equivalent pain relief in comparison to ankle arthrodesis (AA). It is important to consider patient age, weight, coronal tibiotalar deformity, joint line height, and adjacent joint OA to maximize clinical and patient outcomes. Both mobile-bearing and fixed-bearing implants have demonstrated favorable clinical outcomes, marked improvement in patient-reported outcomes, and good survivorship; however, implant survivorship decreases with longer term follow-up, necessitating constant improvement of primary and revision TAR options.


Assuntos
Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo , Osteoartrite , Humanos , Artroplastia de Substituição do Tornozelo/métodos , Artroplastia de Substituição do Tornozelo/instrumentação , Osteoartrite/cirurgia , Articulação do Tornozelo/cirurgia , Resultado do Tratamento , Prótese Articular , Desenho de Prótese , Medidas de Resultados Relatados pelo Paciente
2.
Surg Radiol Anat ; 46(9): 1411-1419, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39043950

RESUMO

PURPOSE: The aim of this study is to reveal the morphometry of the distal tibia and posterior malleolus and to generate morphometric reference data for the tibial component of total ankle prosthesis. METHODS: This study was performed on 121 human dry tibiae (47 right, 74 left). The morphometric measurements of distal tibial structures, tibial length and the distance between the medial and posterior malleolus were measured in this study. Measurements on 44 tibiae were repeated three times and averaged for minimizing intra-observer error. RESULTS: The tibial length was found 34.19 ± 2.31 cm. Mean values of width of fibular notch at tibial plafond and 10 mm proximal to the tibial plafond were 25.71 ± 2.44 mm and 17.81 ± 2.46 mm, respectively. Mean depth of fibular notch at tibial plafond and 10 mm proximal to the tibial plafond were 3.60 ± 1.04 mm and 3.37 ± 1.24 mm, respectively. Mean height of fibular notch was found 48.21 ± 10.51 mm. Mean width and height of medial malleolus were 25.08 ± 2.13 mm and 14.73 ± 1.85 mm, respectively. Mean width and length of tibial plafond were 27.71 ± 2.74 mm and 26.96 ± 2.62 mm, respectively. Mean values of width and height of posterior malleolus were measured 21.41 ± 3.26 mm and 6.74 ± 1.56 mm, respectively. Mean distance between medial and posterior malleolus was found 37.17 ± 3.53 mm. Mean width and depth of malleolar groove were 10.26 ± 1.84 mm and 1.73 ± 0.75 mm, respectively. The mean intra-class correlation values were found between the 0.959 and 0.999. CONCLUSIONS: Knowing the distal tibial morphometry is crucial for designing convenient ankle replacement implants for Turkish population. To our knowledge, this study is the first in the literature that identifies posterior malleolar morphometry on dry tibiae. We believe that this study will make a significant contribution to the literature about distal tibial morphometry and especially the posterior malleolus and the data of our study can be used for designing total ankle prosthesis in Turkish population.


Assuntos
Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo , Cadáver , Tíbia , Humanos , Tíbia/anatomia & histologia , Tíbia/cirurgia , Articulação do Tornozelo/anatomia & histologia , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Artroplastia de Substituição do Tornozelo/instrumentação , Masculino , Feminino , Prótese Articular , Pessoa de Meia-Idade , Idoso
3.
Foot Ankle Int ; 45(9): 950-961, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38872312

RESUMO

BACKGROUND: The management of failed total ankle replacements, with significant loss of bone stock, is challenging with high rates of complications and associated morbidity. Recent technological advances have enabled the development of patient-customized 3D-printed titanium truss arthrodesis implants, which offer an alternative salvage option for failed total ankle replacements. METHODS: A prospective observational study was performed of 6 cases of failed total ankle replacements that were managed using custom patient-specific 3D-printed titanium truss arthrodesis implants. Technical tips, classification, and a treatment algorithm were developed based on our initial experience. RESULTS: Between November 2018 and March 2022, 6 patients underwent arthrodesis for failed total ankle replacements. Follow-up was available for all cases. The mean follow-up was 3.0 years (range 1-4.5). The mean MOXFQ Index improved from 73.1 to 32.3 (P < .05). The mean EQ-5D-5L Index improved from 0.366 to 0.743 (P < .05) and the EQ-VAS also improved from 53.0 to 63.3 (P = .36). The mean VAS-Pain score at final follow-up was 27.5. There were no cases of nonunion. None of the patients were smokers. The overall complication rate was 50%. Two patients returned to surgery: one for wound washout following TAR explantation and a second for removal of metalwork 2 years following surgery for a prosthetic joint infection secondary to hematogenous spread. No patients underwent revision fixation or amputation. CONCLUSION: Custom patient-specific 3D-printed titanium truss arthrodesis implants are a viable treatment option for failed total ankle replacements.


Assuntos
Algoritmos , Artrodese , Artroplastia de Substituição do Tornozelo , Impressão Tridimensional , Titânio , Humanos , Artrodese/métodos , Artrodese/instrumentação , Artroplastia de Substituição do Tornozelo/métodos , Artroplastia de Substituição do Tornozelo/instrumentação , Estudos Prospectivos , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Desenho de Prótese , Reoperação , Prótese Articular , Articulação do Tornozelo/cirurgia , Falha de Prótese
4.
Bull Hosp Jt Dis (2013) ; 82(2): 159-163, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739665

RESUMO

Ankle arthritis is becoming more common and can be pain-ful and debilitating. As the disease progresses, degenera-tive cystic changes may be found in the distal fibula, distal tibia, and talus. After failure of non-operative modalities, arthrodesis is often considered the surgical intervention of choice, but this leaves the patient with reduced range of motion, altered gait, and can negatively impact adjacent joints of the foot. Total ankle arthroplasty has been found to be an effective surgical option for ankle arthritis but is contraindicated in patients with talar collapse. When this is the case, a more personalized approach for preserving ankle motion is necessary. We present the case of a 65-year-old male with severe right ankle arthritis and talar collapse treated with a custom three-dimensionally printed talus and concurrent total ankle replacement with 2-year follow-up.


Assuntos
Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo , Prótese Articular , Osteoartrite , Impressão Tridimensional , Desenho de Prótese , Tálus , Humanos , Masculino , Artroplastia de Substituição do Tornozelo/métodos , Artroplastia de Substituição do Tornozelo/instrumentação , Idoso , Osteoartrite/cirurgia , Osteoartrite/fisiopatologia , Osteoartrite/diagnóstico por imagem , Tálus/cirurgia , Tálus/diagnóstico por imagem , Tálus/fisiopatologia , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/fisiopatologia , Resultado do Tratamento , Amplitude de Movimento Articular
5.
Foot Ankle Surg ; 30(7): 612-617, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38821820

RESUMO

BACKGROUND: In the past decade, the transfibular approach to Total Ankle Replacement (TAR) has emerged as an alternative to anterior approach with reduced bone resection. The purpose of this systematic review is to report survival, complications, and reoperation rates of transfibular TAR. METHODS: We conducted a systematic search of studies that evaluated complications, reoperations, and survival of transfibular TAR following PRISMA guidelines across PubMed, Scopus and Web of Science. RESULTS: Our review included data from 12 cohorts, comprising 919 patients across 7 countries, with an average age of 62 years (59% posttraumatic). Over an average follow-up period of 3 years, adverse events occurred in 23% of cases, with 18% requiring surgical reintervention, mostly due to hardware removal. The survival rate of the transfibular TAR metal components was 97% at the final follow-up. CONCLUSION: Transfibular TAR demonstrates a 97% survival rate at a 3-year follow-up. LEVEL OF EVIDENCE: Level II.


Assuntos
Artroplastia de Substituição do Tornozelo , Falha de Prótese , Humanos , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/instrumentação , Reoperação , Complicações Pós-Operatórias/etiologia , Prótese Articular/efeitos adversos , Desenho de Prótese , Articulação do Tornozelo/cirurgia
6.
Comput Biol Med ; 175: 108551, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703546

RESUMO

The long-term performance of porous coated tibial implants for total ankle replacement (TAR) primarily depends on the extent of bone ingrowth at the bone-implant interface. Although attempts were made for primary fixation for immediate post-operative stability, no investigation was conducted on secondary fixation. The aim of this study is to assess bone ingrowth around the porous beaded coated tibial implant for TAR using a mechanoregulatory algorithm. A realistic macroscale finite element (FE) model of the implanted tibia was developed based on computer tomography (CT) data to assess implant-bone micromotions and coupled with microscale FE models of the implant-bone interface to predict bone ingrowth around tibial implant for TAR. The macroscale FE model was subjected to three near physiological loading conditions to evaluate the site-specific implant-bone micromotion, which were then incorporated into the corresponding microscale model to mimic the near physiological loading conditions. Results of the study demonstrated that the implant experienced tangential micromotion ranged from 0 to 71 µm with a mean of 3.871 µm. Tissue differentiation results revealed that bone ingrowth across the implant ranged from 44 to 96 %, with a mean of around 70 %. The average Young's modulus of the inter-bead tissue layer varied from 1444 to 4180 MPa around the different regions of the implant. The analysis postulates that when peak micromotion touches 30 µm around different regions of the implant, it leads to pronounced fibrous tissues on the implant surface. The highest amount of bone ingrowth was observed in the central regions, and poor bone ingrowth was seen in the anterior parts of the implant, which indicate improper osseointegration around this region. This macro-micro mechanical FE framework can be extended to improve the implant design to enhance the bone ingrowth and in future to develop porous lattice-structured implants to predict and enhance osseointegration around the implant.


Assuntos
Algoritmos , Artroplastia de Substituição do Tornozelo , Análise de Elementos Finitos , Tíbia , Humanos , Tíbia/cirurgia , Tíbia/diagnóstico por imagem , Artroplastia de Substituição do Tornozelo/instrumentação , Tomografia Computadorizada por Raios X , Modelos Biológicos , Osseointegração/fisiologia , Interface Osso-Implante/diagnóstico por imagem , Prótese Articular
7.
Foot Ankle Surg ; 30(6): 493-498, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38584061

RESUMO

BACKGROUND: Revision of failed total ankle replacement (TAR) is challenging and associated with increased morbidity. Given the increased popularity of TAR in treating end-stage ankle arthritis (ESAA), viable revision options are needed. The objective of this case series is to present a minimum 2-year clinical and radiographic outcomes of patient-specific custom 3D-printed total ankle total talus (TATR) prostheses in this unique subset of patients. METHODS: 19 participants with ESAA and failed primary TAR who underwent TATR by a single surgeon at our institution from 2019 to 2021 were retrospectively identified. All participants were indicated for revision of primary STAR implant (Stryker, Kalamazoo, MI) and underwent replacement with 3D-printed titanium implants based on preoperative CT analysis (Additive Orthopaedics, Little Silver, NJ). Custom components included a mobile-bearing total talus and stemmed tibial system, performed through an anterior approach. Pre- and postoperative patient-reported outcomes were assessed using the Patient Reported Outcomes Measurement Information System (PROMIS). Pre- and postoperative implant alignment was assessed using medial distal tibial angle (MDTA) and tibiotalar angle (TTA) on anteroposterior, and sagittal tibial angle (STA) on lateral weight-bearing plain films. RESULTS: The average patient age was 60.6 (range, 39-77) years, with an average follow-up of 37.9 (range, 25.3-57.5) months. There was statistically significant improvement in all PROMIS domains. Short-term survivorship was 100%, with two participants (11.0%) requiring reoperation for postoperative complications: one underwent open reduction internal fixation of the tibia for a periprosthetic fracture, and another underwent medial gutter debridement and tarsal tunnel release for recurrent pain. There were no significant differences in pre- versus postoperative radiographic alignment measured by MDTA (89.9 vs 86.4), TTA (89.7 vs 88.1), or STA (85.2 vs 85.3). CONCLUSION: Custom 3D-printed TATR is a promising option for revision TAR. There was significant short-term improvement in pain and physical function, with excellent short-term survivorship and an acceptable postoperative complication rate.


Assuntos
Artroplastia de Substituição do Tornozelo , Prótese Articular , Reoperação , Tálus , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Tálus/cirurgia , Tálus/diagnóstico por imagem , Idoso , Desenho de Prótese , Impressão Tridimensional , Adulto , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Osteoartrite/cirurgia , Falha de Prótese , Resultado do Tratamento
8.
Foot Ankle Surg ; 30(5): 382-388, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38453589

RESUMO

BACKGROUND: This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY™ with ADAPTIS™ total ankle arthroplasty (TAA) system. METHODS: A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY™ with ADAPTIS™ implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency. RESULTS: Thirty patients were included with median follow-up of 26 months (range, 24-36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency > 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies > 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly. CONCLUSION: TAA performed with the 3-D printed INFINITY™ with ADAPTIS™ implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis. LEVEL OF EVIDENCE: Level III, Retrospective cohort study, Prognostic.


Assuntos
Artroplastia de Substituição do Tornozelo , Prótese Articular , Impressão Tridimensional , Desenho de Prótese , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Seguimentos , Projetos Piloto , Adulto , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Osteoartrite/cirurgia , Medidas de Resultados Relatados pelo Paciente , Porosidade
9.
J Bone Joint Surg Am ; 106(9): 767-775, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38442190

RESUMO

BACKGROUND: Total ankle replacements (TARs) have rapidly advanced in terms of volume, technique, design, and indications. However, TARs are still at risk for early mechanical failure and revision. Prior studies have investigated potential risk factors for failure, but have been limited to smaller series or older implants. This study sought to identify risk factors for early mechanical failure in modern TAR. METHODS: This is a retrospective study of a single-institution registry. Five surgeons contributed cases involving patients who underwent a primary TAR with any implant. Implants were grouped on the basis of the type of fixation. The primary outcome was early mechanical failure (revision with component removal for a non-infectious etiology, that is, subsidence, aseptic loosening, and/or malalignment). Logistic regression determined the effects of age, weight, hindfoot arthrodesis, implant type, and radiographic deformity on failure. RESULTS: The 731 included patients had a mean follow-up of 2.7 years. Ten percent (71 patients) had hindfoot arthrodesis. There were 33 mechanical failures (4.5%) at a mean of 1.7 years after the index surgical procedure. Our model demonstrated that hindfoot arthrodesis was associated with 2.7 times greater odds of failure (p = 0.045), every 10 kg of body weight increased the odds of tibial-sided failure by 1.29 times (p = 0.039), and implants with more extensive tibial fixation (stems or keels) lowered the odds of tibial failure by 95% (p = 0.031). CONCLUSIONS: In patients with uncontrollable risk factors (hindfoot arthrodesis) or risk factors that may or may not be modifiable by the patient (weight), implants with more robust tibial fixation may be able to reduce the risk of early mechanical failure. Further research is warranted to support efforts to decrease early failure in TAR. LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Substituição do Tornozelo , Falha de Prótese , Reoperação , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Substituição do Tornozelo/métodos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Fatores de Risco , Idoso , Reoperação/estatística & dados numéricos , Prótese Articular/efeitos adversos , Desenho de Prótese , Articulação do Tornozelo/cirurgia , Artrodese/instrumentação , Artrodese/métodos , Artrodese/efeitos adversos , Adulto
10.
Foot Ankle Surg ; 30(4): 275-284, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38388212

RESUMO

BACKGROUND: Main objective of this research is to know if there is a different survival rate between fixed bearing (FB) and mobile bearing (MB) total ankle replacement (TAR). We hypothesized that there are no differences between the survival rates of both implants. METHODS: A systematic search was performed in PubMed, Cochrane, EMBASE and ClinicalTrials.gov databases to identify published studies from August 2018 to September 2022 including results for FB and MB TAR survivorship. Inclusion criteria included 1) primary TAR in one or both feet in which implant could be identified , 2) a minimum of 20 procedures reported, 3) reported implant survivorship or calculable and 4) a minimum of 12 months follow-up for level 1-3 studies or 60 months for level 4 studies. RESULTS: 3902 ankles in 28 studies were included. 719 were FB and 3104 MB with an overall survivorship of 94% (95% CI [0.89; 0.97]) and 89% (95% CI [0.86; 0.92]) respectively. After subgroup analysis, we did not find differences among both groups (p =  0.429 ). Meta-regression analysis showed that longer follow-up was associated with lower survival rates in MB group (p = 0.000) while no other relationships were found with other factors (age, level of evidence or conflict of interests). CONCLUSIONS: No differences in survival rates between both groups were found. Age and other studied confounders were not found to be related with implant survivorship. However, longer follow-up was found to be related with lower survival rates. Studies with longer follow-up and higher level of evidence are needed to confirm results. LEVEL OF EVIDENCE: IV, systematic review of level I to IV studies.


Assuntos
Artroplastia de Substituição do Tornozelo , Prótese Articular , Falha de Prótese , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Desenho de Prótese , Articulação do Tornozelo/cirurgia
11.
J Orthop Res ; 42(7): 1536-1544, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38327023

RESUMO

The success of uncemented total ankle replacement (TAR) is linked to initial stability because bony ingrowth depends upon limited early micromotion. Tibial implant design fixation features resist micromotion aided by bony sidewall retention and interference fit. Our goal was to investigate factors influencing implant-bone micromotion in TAR. Two TAR tibial components were virtually inserted into CT-derived computer models of two distal tibias from patients with end-stage ankle arthritis. Density-based inhomogeneous material assignment was used to model bone compaction during press-fit. Finite element analysis (FEA) was used to simulate three fixation cases: (1) no sidewalls + line-to-line fit, (2) sidewalls + line-to-line fit, and (3) sidewalls + 50, 100, or 200 µm interference fit. Kinetic profiles from the stance phase of gait were simulated and micromotions computed from FEA output. Without sidewalls or interference fit, micromotions were largest in early and late stance, with largest micromotions (averaging ~150-250 µm) observed near heel strike. Micromotions decreased 39%-62% when sidewalls were retained. When interference fit was also modeled, micromotions decreased another 37%-61% to ~10 µm. Micromotion differences between patients persisted with sidewall retention but largely disappeared with interference fit. This study presents new insights into the effects of TAR fixation features on implant-bone micromotion. Stability appeared to be influenced by surrounding bone quality, but this influence was greatly diminished when interference fit was introduced. More complete understanding of TAR implant features and performance is needed, but our results show the importance of bone quality and interference fit in the stability of uncemented TAR.


Assuntos
Artroplastia de Substituição do Tornozelo , Análise de Elementos Finitos , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Desenho de Prótese , Tíbia/cirurgia , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Articulação do Tornozelo/cirurgia , Prótese Articular
12.
Foot Ankle Surg ; 30(3): 245-251, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38228466

RESUMO

BACKGROUND: Prosthetic substitution of the talus presents a significant challenge to the foot and ankle surgeon. The shear and compressive forces on the talus and its tenuous blood supply lead to high rates of avascular necrosis and eventual talar collapse. The purpose of this systematic review is to evaluate whether total ankle total talus replacement (TATTR) leads to improved clinical and radiographic outcomes with appropriate safety metrics in patients with a history of avascular necrosis or significant trauma. METHODS: We searched the concepts of talus, prosthesis, and arthroplasty in MEDLINE (PubMed), Embase (Elsevier), CINAHL Complete (EBSCOhost), and Scopus (Elsevier) from the database's inception through March 9, 2023. Inclusion Criteria were 1) previous trauma to the talus, 2) post-traumatic arthritis to the tibiotalar joint, 3) avascular necrosis of talus, 4) multiple failed prior interventions, 5) degenerative osteoarthritis to the tibiotalar joint, and 6) inflammatory arthropathy to tibiotalar joint. Patients less than 18 years of age and manuscripts in non-English languages were excluded. RESULTS: Of the 7625 references, 16 studies met the inclusion criteria, yielding data from 136 patients (139 ankles). The studies varied in design, with case reports and retrospective case series being predominant. The overall weighted average modified Coleman Methodology Score (mCMS) was 70.4 out of 100, indicating moderate flaws in study design that may be subject to various forms of bias and possible confounders. Demographics showed a diverse range of etiologies, with alumina ceramic being the primary prosthesis material. Functional scores demonstrated improvements in dorsiflexion and plantarflexion, although patient-reported outcome measures (PROs) were inconsistently reported. Complications included fractures, heterotopic ossification, prolonged wound healing, and infections. Revision details were sparsely reported. CONCLUSION: TATTR is a promising treatment modality for improving short-term functional outcomes for patients with avascular necrosis or trauma-related issues. However, this systematic review underscores the need for standardized reporting, longer-term follow-ups, and further research to establish the procedure's efficacy and safety, particularly in comparison to other treatment modalities. LEVEL OF EVIDENCE: III, Systematic Review of Level IV Studies.


Assuntos
Artroplastia de Substituição do Tornozelo , Tálus , Humanos , Tálus/cirurgia , Tálus/diagnóstico por imagem , Artroplastia de Substituição do Tornozelo/instrumentação , Artroplastia de Substituição do Tornozelo/efeitos adversos , Osteonecrose/cirurgia , Osteonecrose/etiologia , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Resultado do Tratamento , Prótese Articular
13.
J Foot Ankle Surg ; 63(3): 337-344, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38190880

RESUMO

Total ankle arthroplasty continues to gain popularity amongst surgeons and patients as an alternative to arthrodesis. Historically the designs of early implants were plagued with complications and frequently abandoned. Since that time the procedure and materials have undergone significant advancements in both surgical approach as well as design and function of the available implants. In this study, 40 consecutive patients who received a semiconstrained prosthesis with a unique fixed-bearing polyethylene insert were identified. Minimum follow-up was 2 y. Demographic, social, and past medical data was retrospectively reviewed. Concomitant procedures were also recorded. Radiographic analysis included lateral ankle radiograph postoperative range of motion (ROM) with maximum dorsiflexion and maximum plantarflexion weight bearing at the most recent clinic visit. Clinical outcomes included VAS, FFI, and AOFAS scores. Lateral radiographs taken in the office at a minimum 2-y follow-up showed mean maximum dorsiflexion of 11.8 degrees and plantarflexion of 13.9 degrees. VAS, FFI, and AOFAS scores improved from 8.1, 92.9, and 44.8 to 1.4, 15.3, and 90.1 postoperatively, respectively. A total of 2.5% (n = 1) required revision surgery for poly failure, and 5.0% (n = 2) underwent local wound care in the office setting postoperatively and healed without complications. Overall survivorship was 97.5% at the minimum follow-up of 2 y. In conclusion, similar studies have reported survivorship from 90% to 100% with modern ankle implants in short to mid-term follow-up. Although this is a small sample size, our data shows a 97.5% survivorship at 2 y postoperatively with favorable patient-reported statistically significant functional outcome scores, and ankle range of motion consistent with existing literature.


Assuntos
Articulação do Tornozelo , Artroplastia de Substituição do Tornozelo , Prótese Articular , Desenho de Prótese , Amplitude de Movimento Articular , Humanos , Artroplastia de Substituição do Tornozelo/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Resultado do Tratamento , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Adulto , Seguimentos , Osteoartrite/cirurgia , Suporte de Carga , Idoso de 80 Anos ou mais , Radiografia
14.
J Bone Joint Surg Am ; 103(22): 2080-2088, 2021 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-34424866

RESUMO

BACKGROUND: Currently, the implants utilized in total ankle arthroplasty (TAA) are divided between mobile-bearing 3-component and fixed-bearing 2-component designs. The literature evaluating the influence of this mobility difference on implant survival is sparse. The purpose of the present study was therefore to compare the short-term survival of 2 implants of similar design from the same manufacturer, surgically implanted by the same surgeons, in fixed-bearing or mobile-bearing versions. METHODS: All patients were enrolled who underwent TAA with either the mobile-bearing Salto (Tornier and Integra) or the fixed-bearing Salto Talaris (Integra) in 3 centers by 2 surgeons between January 2004 and March 2018. All patients who underwent TAA from January 2004 to April 2013 received the Salto implant, and all patients who underwent TAA after November 2012 received the Salto Talaris implant. The primary outcome was time, within 3 years, to first all-cause reoperation, revision of any metal component, and revision of any component, including the polyethylene insert. Secondary outcomes included the frequency, cause, and type of reoperation. RESULTS: A total of 302 consecutive patients were included, of whom 171 received the mobile-bearing and 131 received the fixed-bearing implant. The adjusted hazard ratio for all-cause reoperation was 1.42 (95% confidence interval [CI], 0.67 to 3.00; p = 0.36); for component revision, 3.31 (95% CI, 0.93 to 11.79; p = 0.06); and for metal component revision, 2.78 (95% CI, 0.58 to 13.33; p = 0.20). A total of 31 reoperations were performed in the mobile-bearing group compared with 14 in the fixed-bearing group (p = 0.07). More extensive reoperation procedures were performed in the mobile-bearing group. CONCLUSIONS: With the largest comparison of 2 implants of similar design from the same manufacturer, the present study supports the use of a fixed-bearing design in terms of short-term failure. We found a 3-times higher rate of revision among mobile-bearing implants compared with fixed-bearing implants at 3 years after TAA. Reoperations, including first and subsequent procedures, tended to be less common and the causes and types of reoperations less extensive among fixed-bearing implants. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Substituição do Tornozelo/efeitos adversos , Prótese Articular/efeitos adversos , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Idoso , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Estudos de Coortes , Feminino , Seguimentos , Humanos , Prótese Articular/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
Int Orthop ; 45(9): 2445-2452, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34345975

RESUMO

BACKGROUND: Patient-specific instrument (PSI) may theoretically make total ankle arthroplasty (TAA) more accurate. Several studies have reported the outcomes of PSI TAA. The aim of this study is to systematically review the literature of PSI TAA. METHODS: PubMed, Embase, Web of Science, and Cochrane Library databases were systematically reviewed according to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines for PSI TAA. The quality of the included studies was evaluated according to Methodological Index for Non-Randomized Studies (MINORS). RESULT: Nine articles were ultimately included in the systematic review. The implant position and function outcome of TAA was similar between PSI and SI. Prediction accuracy of implant size remained great difference. PSI can shorten the operative time and fluoroscopy time. The quality of current studies on PSI TAA is insufficient to produce high-level evidence. CONCLUSION: PSI can get similar implant position and clinical outcome in TAA compared to SI, but current evidence is not strong enough to evaluate PSI TAA.


Assuntos
Tornozelo , Artroplastia de Substituição do Tornozelo , Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Humanos , Duração da Cirurgia
16.
Arthritis Care Res (Hoboken) ; 73(9): 1275-1281, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-32475031

RESUMO

OBJECTIVE: To describe early prosthesis implantations in a cohort of patients with juvenile idiopathic arthritis (JIA) followed in a tertiary referral hospital and to analyze possible factors influencing implant survival. METHODS: This was a retrospective cohort study. Charts of all patients with JIA who underwent total joint replacement at Gaetano Pini Hospital, Milan, Italy from January 1992 to June 2019 were retrieved, and relevant data were analyzed. RESULTS: Eighty-five patients met the inclusion criteria for this study, with a median follow-up period of 17.2 years. The median age at first prosthesis was 22.7 years. The total number of replaced joints was 198 over a period of 27 years. The hip was the most frequently replaced joint, accounting for almost two-thirds of the total number of implants; the other one-third refers mostly to knee implants. Polyarticular JIA and systemic JIA were the most represented JIA categories in the study cohort. A significant upward trend of the age at arthroplasty and of disease duration before arthroplasty over decades was found. The rates of implant survival at 5, 10, and 15 years were comparable (from 84% to 89%); 50% of implants lasted ≥20 years. CONCLUSION: We reported retrospective data on early joint replacement in a cohort of patients with JIA. We observed a progressive and significant upward trend of both age at arthroplasty and disease duration before the first arthroplasty over time. The JIA category, year of implant, and presence of complications significantly affected implant survivorship.


Assuntos
Artrite Juvenil/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Artroplastia de Quadril/instrumentação , Artroplastia do Joelho/instrumentação , Prótese de Quadril , Articulações/cirurgia , Prótese do Joelho , Adolescente , Adulto , Fatores Etários , Artrite Juvenil/diagnóstico , Artrite Juvenil/fisiopatologia , Artroplastia de Substituição do Tornozelo/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Feminino , Humanos , Itália , Articulações/diagnóstico por imagem , Articulações/fisiopatologia , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
17.
J Orthop Res ; 39(4): 797-805, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33251621

RESUMO

The International Standard Organization, ISO 22622, specifies two options for joint wear simulator evaluation of total ankle replacements (TARs): load-controlled and displacement-controlled. In the present study, the load-controlled testing parameters were applied to cadaveric specimens to quantify and compare the observed sagittal translations and axial rotations to those specified under the displacement-controlled option. Twelve cadaveric specimens were stripped of extraneous tissues, keeping surrounding ankle ligaments. A halo was used to produce plantarflexion and dorsiflexion of the talus through two screws, while a baseplate resisted axial loads. The axial force and torque were applied to the tibia and fibula under force and torque feedback control. An anterior-posterior force was applied to the tibia. Plantarflexion-dorsiflexion were applied using rotation control. To protect the cadaveric specimens, loads were applied at 50% of the specified load profile while plantarflexion-dorsiflexion rotation was applied as specified. There was variation among specimens in magnitudes of anterior-posterior displacement with peaks ranging from 3.3 mm posteriorly to 3.0 mm anteriorly. Likewise, there was variation among specimens in magnitude of axial rotation, with peaks ranging from 11° external rotation to 4.5° internal rotation. However, the mean magnitudes of AP displacement and axial rotation did not exceed those specified by ISO 22622.


Assuntos
Artroplastia de Substituição do Tornozelo/instrumentação , Teste de Materiais , Desenho de Prótese , Tálus/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/cirurgia , Artroplastia de Substituição do Tornozelo/métodos , Parafusos Ósseos , Cadáver , Desenho de Equipamento , Feminino , Humanos , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Rotação , Estresse Mecânico , Torque , Suporte de Carga
18.
J Orthop Traumatol ; 21(1): 16, 2020 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-32876778

RESUMO

BACKGROUND: Computer navigation and patient-specific instrumentation for total ankle arthroplasty have still to demonstrate their theoretical ability to improve implant positioning and functional outcomes. The purpose of this paper is to present a new and complete total ankle arthroplasty customization process for severe posttraumatic ankle joint arthritis, consisting of patient-specific 3D-printed implant and instrumentation, starting from a ligament-compatible design. CASE PRESENTATION: The new customization process was proposed in a 57-year-old male patient and involved image analysis, joint modeling, prosthesis design, patient-specific implant and instrumentation development, relevant prototyping, manufacturing, and implantation. Images obtained from a CT scan were processed for a 3D model of the ankle, and the BOX ankle prosthesis (MatOrtho, UK) geometries were customized to best fit the model. Virtual in silico, i.e., at the computer, implantation was performed to optimize positioning of these components. Corresponding patient-specific cutting guides for bone preparation were designed. The obtained models were printed in ABS by additive manufacturing for a final check. Once the planning procedure was approved, the models were sent to final state-of-the-art additive manufacturing (the metal components using cobalt-chromium-molybdenum powders, and the guides using polyamide). The custom-made prosthesis was then implanted using the cutting guides. The design, manufacturing, and implantation procedures were completed successfully and consistently, and final dimensions and location for the implant corresponded with the preoperative plan. Immediate post-op X-rays showed good implant positioning and alignment. After 4 months, clinical scores and functional abilities were excellent. Gait analysis showed satisfactory joint moment at the ankle complex and muscle activation timing within normality. CONCLUSIONS: The complete customization process for total ankle arthroplasty provided accurate and reliable implant positioning, with satisfactory short-term clinical outcomes. However, further studies are needed to confirm the potential benefits of this complete customization process. LEVEL OF EVIDENCE: 5.


Assuntos
Articulação do Tornozelo , Artrite/cirurgia , Artroplastia de Substituição do Tornozelo/instrumentação , Prótese Articular , Impressão Tridimensional , Desenho de Prótese , Artrite/diagnóstico por imagem , Artroplastia de Substituição do Tornozelo/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
19.
Foot Ankle Int ; 41(12): 1519-1528, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32791850

RESUMO

BACKGROUND: The Salto Talaris is a fixed-bearing implant first approved in the US in 2006. While early surgical outcomes have been promising, mid- to long-term survivorship data are limited. The aim of this study was to present the survivorship and causes of failure of the Salto Talaris implant, with functional and radiographic outcomes. METHODS: Eighty-seven prospectively followed patients who underwent total ankle arthroplasty with the Salto Talaris between 2007 and 2015 at our institution were retrospectively identified. Of these, 82 patients (85 ankles) had a minimum follow-up of 5 (mean, 7.1; range, 5-12) years. The mean age was 63.5 (range, 42-82) years and the mean body mass index was 28.1 (range, 17.9-41.2) kg/m2. Survivorship was determined by incidence of revision, defined as removal/exchange of a metal component. Preoperative, immediate, and minimum 5-year postoperative AP and lateral weightbearing radiographs were reviewed; tibiotalar alignment (TTA) and the medial distal tibial angle (MDTA) were measured to assess coronal talar and tibial alignment, respectively. The sagittal tibial angle (STA) was measured; the talar inclination angle (TIA) was measured to evaluate for radiographic subsidence of the implant, defined as a change in TIA of 5 degrees or more from the immediately to the latest postoperative lateral radiograph. The locations of periprosthetic cysts were documented. Preoperative and minimum 5-year postoperative Foot and Ankle Outcome Score (FAOS) subscales were compared. RESULTS: Survivorship was 97.6% with 2 revisions. One patient underwent tibial and talar component revision for varus malalignment of the ankle; another underwent talar component revision for aseptic loosening and subsidence. The rate of other reoperations was 21.2% (n = 18), with the main reoperation being exostectomy with debridement for ankle impingement (n = 12). At final follow-up, the average TTA improved 4.4 (± 3.8) degrees, the average MDTA improved 3.4 (± 2.6) degrees, and the average STA improved 5.3 (± 4.5) degrees. Periprosthetic cysts were observed in 18 patients, and there was no radiographic subsidence. All FAOS subscales demonstrated significant improvement at final follow-up. CONCLUSIONS: We found the Salto Talaris implant to be durable, consistent with previous studies of shorter follow-up lengths. We observed significant improvement in radiographic alignment as well as patient-reported clinical outcomes at a minimum 5-year follow-up. LEVEL OF EVIDENCE: Level IV, retrospective case series.


Assuntos
Artroplastia de Substituição do Tornozelo/instrumentação , Prótese Articular , Desenho de Prótese , Falha de Prótese , Reoperação/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Inquéritos e Questionários
20.
Biomed Mater Eng ; 31(2): 119-129, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32568171

RESUMO

BACKGROUND: Fourier-transform infrared spectroscopy (FTIR) is one of the standard methods to analyze ultra-high molecular weight polyethylene (UHMWPE) in orthopedic implants. For retrieved components, lipid extraction using an organic solvent prior to the measurement is necessary to eliminate the influence of lipids absorbed in vivo. However, its influence on the measurement has not been substantially investigated. OBJECTIVE: To investigate the influence of lipid extraction on the FTIR analysis of UHMWPE and to develop a novel method to obtain reliable results without inconvenient lipid extraction. METHODS: FTIR analysis was repeatedly performed on UHMWPE specimens from retrieved components before and after lipid extraction under various conditions. A method to calculate the extent of influence of the absorbed lipids from the FTIR spectra was developed using a peak separation technique. RESULTS: An elevated temperature was necessary for lipid extraction; however, it had the potential to influence the results if the conditions were not properly controlled. The results obtained using the peak separation technique coincided with those obtained after lipid extraction. CONCLUSION: The use of the peak separation technique enables the efficient acquisition of reliable results without the need for lipid extraction.


Assuntos
Análise de Falha de Equipamento/métodos , Lipídeos/farmacocinética , Polietilenos/química , Polietilenos/farmacocinética , Absorção Fisico-Química , Adulto , Tornozelo , Artroplastia de Substituição do Tornozelo/instrumentação , Artroplastia de Quadril/instrumentação , Fracionamento Químico , Remoção de Dispositivo , Feminino , Prótese de Quadril , Humanos , Lipídeos/isolamento & purificação , Lipídeos/farmacologia , Teste de Materiais , Oxirredução , Reoperação , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA