Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.580
Filtrar
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38728442

RESUMO

CASE: A 71-year-old woman presented with post-traumatic arthritis 11 months after open reduction and internal fixation for a left proximal humerus fracture (PHF) dislocation. After revision to reverse total shoulder arthroplasty (rTSA), the patient's left upper extremity was found to be avascular. An emergent thrombectomy was performed with restoration of arterial flow after removal of an acute-on-chronic axillary artery thrombus. CONCLUSION: Although rare, as rTSA becomes more common for management of PHF, incidence of associated vascular injuries is likely to rise. Screening methods and clinical vigilance in diagnosis are advised for patients with anterior PHF dislocations and arterial injury risk factors.


Assuntos
Artroplastia do Ombro , Artéria Axilar , Fraturas do Ombro , Trombose , Humanos , Feminino , Idoso , Artéria Axilar/cirurgia , Artéria Axilar/lesões , Artéria Axilar/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Artroplastia do Ombro/efeitos adversos , Trombose/etiologia , Trombose/diagnóstico por imagem , Trombose/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Redução Aberta/efeitos adversos , Reoperação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38722914

RESUMO

INTRODUCTION: Anatomic and reverse total shoulder arthroplasties (TSAs) are effective treatment options for end-stage glenohumeral osteoarthritis. Those undergoing TSA may also have fibromyalgia, a musculoskeletal condition. However, the association of fibromyalgia with shorter and longer term outcomes after TSA has not been well characterized. METHODS: Patients undergoing TSA for osteoarthritis indications were identified in the PearlDiver M165 database from January 2016 to October 2022. Exclusion criteria included age younger than 18 years, shoulder infection, neoplasm, or trauma within 90 days before surgery, and inactivity in the database within 90 days of surgery. Patients with fibromyalgia were matched in a 1:4 ratio to patients without based on age, sex, and Elixhauser Comorbidity Index. Ninety-day adverse events were compared using univariable and multivariable analyses. Five-year revision-free survival was compared using the log-rank test. RESULTS: Of 163,565 TSA patients, fibromyalgia was identified for 9,035 (5.52%). After matching, cohorts of 30,770 non-fibromyalgia patients and 7,738 patients with fibromyalgia were identified. Multivariable analyses demonstrated patients with fibromyalgia were at independently increased odds ratios (ORs) for the following 90-day complications (decreasing OR order): urinary tract infection (OR = 4.49), wound dehiscence (OR = 3.63), pneumonia (OR = 3.46), emergency department visit (OR = 3.45), sepsis (OR = 3.15), surgical site infection (OR = 2.82), cardiac events (OR = 2.72), acute kidney injury (OR = 2.65), deep vein thrombosis (OR = 2.48), hematoma (OR = 2.03), and pulmonary embolism (OR = 2.01) (P < 0.05 for each). These individual complications contributed to the increased odds of aggregated minor adverse events (OR = 3.68), all adverse events (OR = 3.48), and severe adverse events (OR = 2.68) (P < 0.05 for each). No statistically significant difference was observed in 5-year revision-free survival between groups. DISCUSSION: This study found TSA patients with fibromyalgia to be at increased risk of adverse events within 90 days of surgery. Proper surgical planning and patient counseling are crucial to this population. Nonetheless, it was reassuring that those with fibromyalgia had similar 5-year revision-free survival compared with those without.


Assuntos
Artroplastia do Ombro , Fibromialgia , Complicações Pós-Operatórias , Humanos , Feminino , Fibromialgia/complicações , Masculino , Complicações Pós-Operatórias/epidemiologia , Idoso , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Fatores de Risco , Estudos Retrospectivos
3.
BMC Musculoskelet Disord ; 25(1): 396, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38773483

RESUMO

PURPOSE: This systematic review aims to provide an overview of the current knowledge on the role of the metaverse, augmented reality, and virtual reality in reverse shoulder arthroplasty. METHODS: A systematic review was performed using the PRISMA guidelines. A comprehensive review of the applications of the metaverse, augmented reality, and virtual reality in in-vivo intraoperative navigation, in the training of orthopedic residents, and in the latest innovations proposed in ex-vivo studies was conducted. RESULTS: A total of 22 articles were included in the review. Data on navigated shoulder arthroplasty was extracted from 14 articles: seven hundred ninety-three patients treated with intraoperative navigated rTSA or aTSA were included. Also, three randomized control trials (RCTs) reported outcomes on a total of fifty-three orthopedics surgical residents and doctors receiving VR-based training for rTSA, which were also included in the review. Three studies reporting the latest VR and AR-based rTSA applications and two proof of concept studies were also included in the review. CONCLUSIONS: The metaverse, augmented reality, and virtual reality present immense potential for the future of orthopedic surgery. As these technologies advance, it is crucial to conduct additional research, foster development, and seamlessly integrate them into surgical education to fully harness their capabilities and transform the field. This evolution promises enhanced accuracy, expanded training opportunities, and improved surgical planning capabilities.


Assuntos
Artroplastia do Ombro , Realidade Aumentada , Realidade Virtual , Humanos , Artroplastia do Ombro/métodos , Cirurgia Assistida por Computador/educação , Cirurgia Assistida por Computador/métodos , Articulação do Ombro/cirurgia
4.
Sports Med Arthrosc Rev ; 32(1): 17-21, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38695499

RESUMO

Rotator cuff tears are the most frequent shoulder injury in patients over 50 years old. Treatment of rotator cuff tears is individualized based on the age, demands, and symptoms of the patient. Nonoperative treatment may often be effective, especially in lower-demand or elderly patients. Surgical repair is indicated after failure of nonoperative treatment or in patients whose high-demand lifestyle requires full strength and function of the shoulder. In older patients, larger tears are less likely to heal and rotator cuff repair may not reliable. In cases of failed previous rotator cuff repair, there may not be enough viable tissue for complete repair. If there is underlying arthritis, a rotator cuff repair is unlikely to resolve all symptoms, and treatment to care for the arthritis and rotator cuff tear is indicated. Reverse shoulder arthroplasty provides the surgical answer for these scenarios and is now being used for numerous indications of shoulder pathology.


Assuntos
Artroplastia do Ombro , Lesões do Manguito Rotador , Humanos , Lesões do Manguito Rotador/cirurgia , Artroplastia do Ombro/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-38754005

RESUMO

BACKGROUND: This study focuses on investigating the risk factors of increased operating room time and patient complication rates after total shoulder arthroplasty cases (both reverse and anatomic). We hypothesize that the use of surgeon-preferred staff will improve operating room efficiency and reduce complication rates while increased staff turnover will decrease efficiency and increase complications. METHODS: This is a single-center, retrospective study focused on determining the effects of staffing on operating room time and efficiency in total shoulder arthroplasty. The study included patients who underwent total shoulder arthroplasty by a single fellowship-trained orthopaedic surgeon from 2018 to 2023. RESULTS: Four hundred twenty-three patients were included in the study from August 2018 to April 2023, 264 of which were reverse total shoulder arthroplasty (rTSA) and 159 were anatomic total shoulder arthroplasty (aTSA). In both rTSA and aTSA, the presence of surgeon-preferred staff markedly decreased operating room time. In rTSA, staff turnover increased risk of 90-day complications. CONCLUSION: Because the presence of surgeon-preferred staff affects operating room time and efficiency, orthopaedic surgeons should train multiple surgical teams so that efficiency is not affected by the loss of personnel during a case. To reduce 90-day complication rates in rTSA, staff breaks and turnover should be minimized as much as possible because this has a direct effect on patient outcomes. Effort from hospital administration and management should be put toward reducing turnover to improve patient outcomes.


Assuntos
Artroplastia do Ombro , Salas Cirúrgicas , Duração da Cirurgia , Complicações Pós-Operatórias , Humanos , Estudos Retrospectivos , Complicações Pós-Operatórias/epidemiologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Reorganização de Recursos Humanos , Cirurgiões Ortopédicos , Fatores de Risco
6.
Bull Hosp Jt Dis (2013) ; 82(2): 146-153, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38739663

RESUMO

Surgical management of the subscapularis tendon is critical to a successful outcome following anatomic total shoulder arthroplasty. However, the optimal surgical technique for adequate exposure of the glenohumeral joint while mini-mizing complications resulting from subscapularis tendon dysfunction continues to be controversial. Common surgical techniques for the management of the subscapularis tendon include tenotomy, peeling, sparing, and lesser tuberosity oste-otomy. Despite a number of published studies comparing these techniques, no consensus has been reached regarding optimal management. This article reviews the extensive literature on the biomechanical, radiologic, and clinical outcomes of each technique, including recently published comparison studies.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento , Fenômenos Biomecânicos , Tenotomia/métodos , Recuperação de Função Fisiológica , Tendões/cirurgia , Amplitude de Movimento Articular
7.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562639

RESUMO

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Escápula , Amplitude de Movimento Articular , Fenômenos Biomecânicos
8.
Clin Orthop Surg ; 16(2): 294-302, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562643

RESUMO

Background: There are few reports on the revision or reintervention of reverse total shoulder arthroplasty (RTSA) in South Korea. The purpose of this study was to evaluate the true incidence of complications and reintervention of RTSA and clinical and radiological outcomes based on our 14-year experience in RTSA in a Korean population. Methods: Between March 2008 and June 2022, 412 consecutive cases of RTSA were performed in 388 patients with an average age of 74.4 years at our institute. Excluding 23 patients lost to follow-up, 365 patients (373 shoulders including 8 bilateral cases) who underwent primary RTSA with more than 6 months of follow-up were enrolled in this study. We evaluated those who had complications or reintervention including revision RTSA for failed RTSA. Patient charts were reviewed, and clinical outcomes including clinical scores, complications, and reintervention and radiologic outcomes were evaluated at the last follow-up. Results: Among the 373 shoulders that underwent primary RTSA, complications were found in 50 patients (13.94%, 10 men and 40 women with a mean age of 75.9 ± 6.7 years [range, 51-87 years]). The causes of complications were as follows: 13 acromion, coracoid, or scapular spine fractures, 10 loosening (glenoid: 5, humeral stem: 5), 5 infections, 4 periprosthetic fractures, 2 instability, 2 neurologic complications, and 14 miscellaneous complications. Twenty patients (5.63%, 4 men and 16 women with a mean age of 74.2 ± 8.2 years [range, 51-87 years]) underwent reintervention. The interval to the first reintervention was 27.8 ± 23.1 months (range, 0.1-78 months). The causes of reintervention (20 cases) were 8 loosening (glenoid: 4, humeral stem: 4), 5 infections, 5 fractures, and 2 instability. Among them, 15 component revisions (4.02%) were performed. At the last follow-up, American Shoulder and Elbow Surgeons, University of California at Los Angeles, and Simple Shoulder Test scores were improved from 25.4, 12.4, and 1.6 preoperatively to 40.4, 16.2, and 3.2, respectively. Forward flexion (48° to 87°), abduction (52° to 79°), external rotation (18° to 22°), and internal rotation (buttock to L2) were improved. Conclusions: After primary RTSA in a Korean population, the complication, reintervention, and revision rates were 13.94%, 5.63%, and 4.02%, respectively. Careful evaluation of the complications and adequate treatments should be performed.


Assuntos
Artroplastia do Ombro , Fraturas Periprotéticas , Articulação do Ombro , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento , Fraturas Periprotéticas/etiologia , Escápula , Estudos Retrospectivos , Amplitude de Movimento Articular , Reoperação/efeitos adversos
9.
Artigo em Inglês | MEDLINE | ID: mdl-38569086

RESUMO

INTRODUCTION: This study aimed to assess the relationship between preoperative international normalized ratio (INR) levels and major postoperative bleeding events after total shoulder arthroplasty (TSA). METHODS: The American College of Surgeons National Surgical Quality Improvement Program database was queried for TSA from 2011 to 2020. A final cohort of 2405 patients with INR within 2 days of surgery were included. Patients were stratified into four groups: INR ≤ 1.0, 1.0 < INR ≤ 1.25, 1.25< INR ≤ 1.5, and INR > 1.5. The primary outcome was bleeding requiring transfusion within 72 hours, and secondary outcome variables included complication, revision surgery, readmission, and hospital stay duration. Multivariable logistic and linear regression analyses adjusted for relevant comorbidities were done. RESULTS: Of the 2,405 patients, 48% had INR ≤ 1.0, 44% had INR > 1.0 to 1.25, 7% had INR > 1.25 to 1.5, and 1% had INR > 1.5. In the adjusted model, 1.0 < INR ≤ 1.25 (OR 1.7, 95% CI 1.176 to 2.459), 1.25 < INR ≤ 1.5 (OR 2.508, 95% CI 1.454 to 4.325), and INR > 1.5 (OR 3.200, 95% CI 1.233 to 8.302) were associated with higher risks of bleeding compared with INR ≤ 1.0. DISCUSSION: The risks of thromboembolism and bleeding lie along a continuum, with higher preoperative INR levels conferring higher postoperative bleeding risks after TSA. Clinicians should use a patient-centered, multidisciplinary approach to balance competing risks.


Assuntos
Artroplastia do Ombro , Tromboembolia , Humanos , Coeficiente Internacional Normatizado/efeitos adversos , Complicações Pós-Operatórias/etiologia , Artroplastia do Ombro/efeitos adversos , Hemorragia Pós-Operatória/etiologia , Hemorragia Pós-Operatória/complicações , Tromboembolia/complicações
11.
BMJ ; 385: e077939, 2024 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-38688550

RESUMO

OBJECTIVES: To answer a national research priority by comparing the risk-benefit and costs associated with reverse total shoulder replacement (RTSR) and anatomical total shoulder replacement (TSR) in patients having elective primary shoulder replacement for osteoarthritis. DESIGN: Population based cohort study using data from the National Joint Registry and Hospital Episode Statistics for England. SETTING: Public hospitals and publicly funded procedures at private hospitals in England, 2012-20. PARTICIPANTS: Adults aged 60 years or older who underwent RTSR or TSR for osteoarthritis with intact rotator cuff tendons. Patients were identified from the National Joint Registry and linked to NHS Hospital Episode Statistics and civil registration mortality data. Propensity score matching and inverse probability of treatment weighting were used to balance the study groups. MAIN OUTCOME MEASURES: The main outcome measure was revision surgery. Secondary outcome measures included serious adverse events within 90 days, reoperations within 12 months, prolonged hospital stay (more than three nights), change in Oxford Shoulder Score (preoperative to six month postoperative), and lifetime costs to the healthcare service. RESULTS: The propensity score matched population comprised 7124 RTSR or TSR procedures (126 were revised), and the inverse probability of treatment weighted population comprised 12 968 procedures (294 were revised) with a maximum follow-up of 8.75 years. RTSR had a reduced hazard ratio of revision in the first three years (hazard ratio local minimum 0.33, 95% confidence interval 0.18 to 0.59) with no clinically important difference in revision-free restricted mean survival time, and a reduced relative risk of reoperations at 12 months (odds ratio 0.45, 95% confidence interval 0.25 to 0.83) with an absolute risk difference of -0.51% (95% confidence interval -0.89 to -0.13). Serious adverse events and prolonged hospital stay risks, change in Oxford Shoulder Score, and modelled mean lifetime costs were similar. Outcomes remained consistent after weighting. CONCLUSIONS: This study's findings provide reassurance that RTSR is an acceptable alternative to TSR for patients aged 60 years or older with osteoarthritis and intact rotator cuff tendons. Despite a significant difference in the risk profiles of revision surgery over time, no statistically significant and clinically important differences between RTSR and TSR were found in terms of long term revision surgery, serious adverse events, reoperations, prolonged hospital stay, or lifetime healthcare costs.


Assuntos
Artroplastia do Ombro , Osteoartrite , Sistema de Registros , Reoperação , Humanos , Inglaterra/epidemiologia , Osteoartrite/cirurgia , Masculino , Feminino , Artroplastia do Ombro/efeitos adversos , Idoso , Pessoa de Meia-Idade , Reoperação/estatística & dados numéricos , Pontuação de Propensão , Estudos de Coortes , Tempo de Internação/estatística & dados numéricos , Resultado do Tratamento , Análise Custo-Benefício , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia
12.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38653836

RESUMO

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Assuntos
Artroplastia do Ombro , Desenho de Prótese , Prótese de Ombro , Humanos , Idoso , Artroplastia do Ombro/métodos , Idoso de 80 Anos ou mais , Feminino , Masculino , Amplitude de Movimento Articular , Estudos Retrospectivos , Radiografia , Resultado do Tratamento , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem
13.
Acta Orthop Belg ; 90(1): 115-122, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38669660

RESUMO

The introduction of fast-track protocols decreased length of hospital stay and improved rehabilitation and outcomes in total joint arthroplasty. Despite improved clinical results published in many papers, the patient perspective of these protocols is less investigated. Purpose of this study was to explore the patient perspective of fast-track protocols in arthroplasty. A systematic search for articles of patient experiences in total hip, knee, and shoulder arthroplasty was conducted using EMBASE, MEDLINE, Cochrane, and Web-of-Science for articles published from inception to February 14, 2023. In total 12 studies were included involving 672 patients. Most patients were satisfied with short length of hospital stay and preferred rehabilitation at home with relatives for support. Various experiences were reported regarding pain and postoperative out of hospital physical therapy. Frequently, feelings of insecurity were reported because of lack of personalized information. Based on current qualitative literature, patients are satisfied with short length of hospital stay in fast-track total joint arthroplasty. Improvements in personalized information and physical therapy protocols is needed.


Assuntos
Tempo de Internação , Satisfação do Paciente , Humanos , Tempo de Internação/estatística & dados numéricos , Artroplastia de Quadril/reabilitação , Artroplastia de Quadril/métodos , Artroplastia do Joelho/reabilitação , Artroplastia do Joelho/métodos , Artroplastia de Substituição/métodos , Artroplastia do Ombro/métodos
14.
Artigo em Inglês | MEDLINE | ID: mdl-38648447

RESUMO

INTRODUCTION: Sex disparities in presentation of osteoarthritis and utilization of joint replacement surgery (JRS) have been demonstrated. The role of patients' unique perspectives on JRS on their treatment decisions is poorly understood. METHODS: JRS candidates who were offered JRS but declined surgical treatment completed this survey. Survey questions included demographic information, patient experiences and current opinions around JRS, patient experiences with providers, goals and concerns, and barriers to JRS. RESULTS: More women experience barriers to undergoing JRS compared with men (53% versus 16%; P = 0.014). While both men and women indicated pain relief as their primary goal for treatment, women were significantly more likely to prioritize regaining the ability to complete daily tasks and responsibilities when compared with men (P = 0.007). Both men and women indicated that low symptom severity and nonsurgical treatment options were the reasons for not undergoing JRS (P = 0.455). Compared with men, women trended toward feeling that they were not sufficiently educated about JRS (P = 0.051). CONCLUSION: Women have unique perspectives and goals for JRS that may pose sex-specific barriers to care. A better understanding of how patients' gendered experiences affect their decision making is necessary to improve treatment of osteoarthritis and decrease disparities in care.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Feminino , Masculino , Fatores Sexuais , Pessoa de Meia-Idade , Idoso , Artroplastia do Ombro , Inquéritos e Questionários , Osteoartrite do Joelho/cirurgia , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/psicologia , Osteoartrite/cirurgia , Osteoartrite/psicologia
15.
J Orthop Traumatol ; 25(1): 20, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637350

RESUMO

BACKGROUND: This study aims to compare the range of motion (ROM) of reverse shoulder arthroplasty lateralised by bony increased offset (BIO-RSA) using a standard 38-mm (mm) component to regular reverse shoulder arthroplasty (RSA) lateralised by using a 42-mm glenoid component. The secondary aims are to compare patient-reported and radiographic outcomes between the two groups. MATERIALS AND METHODS: All patients with a BIO-RSA and size 38 glenosphere were retrospectively identified and matched to patients with a regular RSA and size 42 glenosphere. Matched patients were invited for a follow-up visit. ROM was assessed as well as radiographic outcomes (lateralisation, distalisation, inferior overhang, scapular notching, heterotopic bone formation, radiolucency, stress shielding, bone graft healing and viability and complications) and patient-reported outcomes (subjective shoulder value, Constant score, American Shoulder and Elbow Surgeons, activities of daily living which require internal rotation, activities of daily living which require external rotation and a visual analogue scale for pain). Outcomes were compared between the two groups. RESULTS: In total, 38 BIO-RSAs with a size 38 glenosphere were matched to 38 regular RSAs with a size 42 glenosphere. Of the 76 matched patients, 74 could be contacted and 70 (95%) were included. At the final follow-up, there were no differences between the two groups in ROM, patient-reported outcomes or radiographic outcomes (p > 0.485). CONCLUSIONS: Using a larger glenosphere is a feasible alternative to BIO-RSA for lateralising RSA, providing comparable ROM, patient-reported and radiographic results, while potentially decreasing costs, operative time and complication rates.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Estudos Retrospectivos , Atividades Cotidianas , Escápula/diagnóstico por imagem , Escápula/cirurgia , Amplitude de Movimento Articular , Resultado do Tratamento
16.
Eur J Orthop Surg Traumatol ; 34(4): 2137-2145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38557891

RESUMO

PURPOSE: When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality. METHODS: RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem. RESULTS: The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05). CONCLUSION: The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.


Assuntos
Artroplastia do Ombro , Úmero , Desenho de Prótese , Prótese de Ombro , Humanos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/efeitos adversos , Idoso , Úmero/cirurgia , Úmero/diagnóstico por imagem , Masculino , Feminino , Prótese de Ombro/efeitos adversos , Idoso de 80 Anos ou mais , Articulação do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Estudos Retrospectivos
17.
Eur J Orthop Surg Traumatol ; 34(4): 2193-2200, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38578440

RESUMO

INTRODUCTION: Revision shoulder arthroplasty can be challenging. One of the main considerations for surgeons is the type of implant that was placed in the initial surgery. Anatomic shoulder arthroplasty (ASA) is used for cases of osteoarthritis as well as for fractures of the humeral head. Hemiarthroplasty can be used for complex proximal humerus fractures. The purpose of this study is to determine whether there is a difference in clinical and radiographic outcomes between patients that failed primary fracture hemiarthroplasty (FHA), or ASA for osteoarthritis and then required reoperation with a conversion to reverse shoulder arthroplasty (RSA). METHODS: Patients with failed anatomic shoulder replacement, who had undergone conversion to RSA, were enrolled after a mean follow-up of 107 (85-157) months. Two different groups, one with failed ASA implanted for osteoarthritis and one with failed FHA, were created. At follow-up patients were assessed with standard radiographs and clinical outcome scores. RESULTS: Twenty-nine patients (f = 17, m = 12; 51%) suffered from a failed ASA (Group A), while the remaining 28 patients (f = 21, m = 74; 49%) had been revised due to a failed FHA (Group B). Patients of Group B had a poorer Constant score (Group A: 60 vs. Group B: 46; p = 0.02). Abduction (Group A: 115° vs. Group B: 89°; p = 0.02) was worse after conversion of a failed FHA to RSA in comparison to conversions of failed ASA. The mean bone loss of the lateral metaphysis was higher in patients with failed FHA (Group A: 5 mm vs. Group B: 20 mm; p = 0.0). CONCLUSION: The initial indication for anatomic shoulder arthroplasty influences the clinical and radiological outcome after conversion to RSA. Conversion of failed FHA to RSA is related to an increased metaphyseal bone loss, decreased range of motion and poorer clinical outcomes when compared to conversions of failed ASA implanted for osteoarthritis. LEVEL OF EVIDENCE: III Retrospective Cohort Comparison Study.


Assuntos
Artroplastia do Ombro , Hemiartroplastia , Osteoartrite , Radiografia , Reoperação , Fraturas do Ombro , Articulação do Ombro , Humanos , Artroplastia do Ombro/métodos , Hemiartroplastia/métodos , Masculino , Feminino , Idoso , Reoperação/estatística & dados numéricos , Reoperação/métodos , Osteoartrite/cirurgia , Osteoartrite/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Amplitude de Movimento Articular , Seguimentos , Estudos Retrospectivos
18.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574183

RESUMO

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Prótese de Ombro , Humanos , Artroplastia do Ombro/efeitos adversos , Articulação do Ombro/cirurgia , Ombro/cirurgia , Prótese de Ombro/efeitos adversos , Manguito Rotador/cirurgia
19.
Bone Joint J ; 106-B(5): 482-491, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688478

RESUMO

Aims: Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods: NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results: A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion: The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.


Assuntos
Artroplastia do Ombro , Cerâmica , Hemiartroplastia , Desenho de Prótese , Falha de Prótese , Reoperação , Prótese de Ombro , Humanos , Reoperação/estatística & dados numéricos , Hemiartroplastia/métodos , Masculino , Feminino , Artroplastia do Ombro/métodos , Idoso , Pessoa de Meia-Idade , Osteoartrite/cirurgia , Sistema de Registros , Cabeça do Úmero/cirurgia , Idoso de 80 Anos ou mais , Metais
20.
Artigo em Inglês | MEDLINE | ID: mdl-38546429

RESUMO

Immobilization for acromial and scapular spine stress AU4fractures (AF/SSF) after reverse total shoulder arthroplasty (RSA) is associated with patient dissatisfaction. Our study reports the effects and safety of intranasal calcitonin alongside sling immobilization on pain and function in the treatment of AF/SSF after RSA. The treatment was regimented calcitonin (salmon) 200 unit/actuation nasal spray (1 spray/day) for 6 weeks with sling immobilization for 4 weeks. Each patient was monitored through blood work. Visual analog scale, American Shoulder and Elbow Surgeons score, and active range of motion were collected preoperatively, postoperatively, at presentation of AF/SSF, and after completion of calcitonin treatment. Two hundred eighty-two RSAs were performed by two board-certified orthopaedic surgeons, of which 18 patients sustained AF/SSF (6.4%). Ten patients met inclusion criteria (nine AFs and one SSF). After calcitonin treatment, patients demonstrated an average improvement of visual analog scale of 5.8 points, active range of motion of 46_, and American Shoulder and Elbow Surgeons score of 43.6 points at average 7.53 months after RSA. No medical complications were reported at 6-month follow-up after calcitonin treatment. The use of intranasal calcitonin was not associated withadverse events including no aberrations/signs of cancer at 6-month follow-up after administration. Calcitonin with sling immobilization markedly improved clinical and functional outcomes of patients with nondisplaced AF/SSF and may be considered by orthopaedic surgeons for symptom management.


Assuntos
Artroplastia do Ombro , Conservadores da Densidade Óssea , Fraturas de Estresse , Humanos , Calcitonina , Artroplastia do Ombro/efeitos adversos , Uso Off-Label , Escápula , Hormônios e Agentes Reguladores de Cálcio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA