Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 332
Filtrar
1.
Skin Res Technol ; 30(8): e13902, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39162189

RESUMO

BACKGROUND: Trypanophobia or "needle phobia" represents a potential hindrance to the effective management of chronic diseases whenever an injectable therapy might be required, especially in case of frequent administrations. Psoriasis, a chronic dermatologic disease, can be effectively treated with biologic drugs administered subcutaneously. Thankfully, anti-IL-23 drugs require few administrations per year and are available in prefilled pens that hide the needle, thus representing a convenient option in patients with trypanophobia. METHODS: An observational multicentric study was conducted on patients with moderate-to-severe psoriasis who were treated with 75 mg × 2 risankizumab prefilled syringe therapy for more than 6 months and reported a loss of efficacy measured by the Psoriasis Area and Severity Index (PASI) from PASI 90 to PASI 75 attributed to a reduction of adherence due to trypanophobia. The patients were switched to 1 prefilled pen of risankizumab 150 mg and asked to fill out the Self-Injection Assessment Questionnaire (SIAQ) before and after the injection at week 0 and at the following administration after 12 weeks. Subjects scored each item of the SIAQ on a 5-point scale, scores were later transformed from 0 (worst experience) to 10 (best experience). RESULTS: Twenty-two patients were enrolled. The mean SIAQ predose domain scores were 5.5 for feelings about injection, 6.2 for self-confidence, and 6.4 for satisfaction with self-injection. After dose scores were higher (> 8.5) for each of the six domains at Week 0 and even higher after 12 weeks (> 9.0). CONCLUSIONS: User-friendly devices, such as prefilled pens, and a lower number of injections improved patient satisfaction in a group of patients with psoriasis on treatment with biologic drugs. We believe that treatment adherence could be positively influenced by such changes in the way of administration of a biologic treatment.


Assuntos
Psoríase , Autoadministração , Humanos , Psoríase/tratamento farmacológico , Psoríase/psicologia , Autoadministração/instrumentação , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Injeções Subcutâneas , Anticorpos Monoclonais/administração & dosagem , Resultado do Tratamento , Satisfação do Paciente , Seringas , Idoso , Inquéritos e Questionários , Índice de Gravidade de Doença
2.
Expert Opin Biol Ther ; 24(7): 681-689, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38905143

RESUMO

BACKGROUND: This study compared the pharmacokinetics (PK), immunogenicity, and safety of candidate tocilizumab biosimilar, CT-P47, administered via auto-injector (CT-P47 AI) or pre-filled syringe (CT-P47 PFS), in healthy Asian adults. RESEARCH DESIGN AND METHODS: In this phase I, multicenter, open-label study, participants were randomized 1:1 to receive a single 162 mg/0.9 mL dose of CT-P47 via AI or PFS. Primary endpoints were area under the concentration - time curve from time zero to infinity (AUC0-inf) and maximum serum concentration (Cmax). PK equivalence was determined if 90% confidence intervals (CIs) for the ratios of geometric least-squares means (gLSMs) were within the predefined 80-125% equivalence margin. Secondary PK parameters, immunogenicity, and safety outcomes were also assessed. RESULTS: Of 314 participants randomized (155 CT-P47 AI; 159 CT-P47 PFS), 310 received the study drug (153 CT-P47 AI; 157 CT-P47 PFS). Primary and secondary PK results, immunogenicity and safety were similar between groups. Ninety percent CIs for the ratio of gLSMs were within the predefined equivalence margin for AUC0-inf (85.87-102.94) and Cmax (82.98-98.16). CONCLUSIONS: PK equivalence between CT-P47 AI and CT-P47 PFS was demonstrated in healthy Asian adults, with comparable immunogenicity and safety between the two devices. TRIAL REGISTRATION: ClinicalTrials.gov: NCT05617183.


Tocilizumab is a biologic medicine used to treat inflammatory diseases, such as rheumatoid arthritis. A biosimilar is a drug that is an almost identical copy of an approved original ('reference') biologic medicine; it has identical efficacy and safety to the original medicine but is typically less expensive. CT­P47 is in development as a possible tocilizumab biosimilar.Some patients prefer injections using an auto-injector (AI) rather than a pre-filled syringe (PFS), for reasons including ease of use and convenience. With an AI, medicine is delivered automatically by firmly pressing the device against the skin, whereas, with a PFS, a needle is inserted into the skin and medicine delivered by depressing the plunger. The injection of CT­P47 using a PFS has shown comparable pharmacokinetics (i.e., the uptake, metabolism and excretion of the drug by the body) and safety to tocilizumab. Therefore, if the pharmacokinetics and safety of CT­P47 administered via AI and PFS were shown to be similar, this might expand the choice of administration devices available to patients.In this study, 310 healthy adults received a single injection of CT­P47 via AI or PFS. Blood samples were taken over 43 days to analyze pharmacokinetics. The uptake, metabolism and elimination of CT­P47 by the body was similar when administered by each device, suggesting that CT­P47 can be administered by either AI or PFS.


Assuntos
Anticorpos Monoclonais Humanizados , Medicamentos Biossimilares , Seringas , Humanos , Masculino , Adulto , Medicamentos Biossimilares/farmacocinética , Medicamentos Biossimilares/administração & dosagem , Medicamentos Biossimilares/efeitos adversos , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/efeitos adversos , Feminino , Pessoa de Meia-Idade , Adulto Jovem , Área Sob a Curva , Autoadministração/instrumentação , Equivalência Terapêutica
3.
PLoS One ; 19(5): e0301851, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696453

RESUMO

This study tested the usability of a home-based self-administration transcranial direct current stimulation (tDCS) device designed specifically for women's health needs. This is a single center triple blinded clinical usability study for a new wireless, Bluetooth-controlled wearable tDCS device for women's health. The study aims to evaluate the usability and effective blinding of a home-based tDCS system. A total of forty-nine women of reproductive age were randomly allocated (1:1) to receive one session of active tDCS (n = 24) or sham tDCS (n = 25) over the motor and dorsolateral prefrontal cortex. Each participant self-administered one 20-minute session without supervision following guidance on a software application alone. The System Usability Scale (SUS) and the Patient Global Impression of Change (PGIC) were used to evaluate the usability of the system. Regardless of sham or active conditions, all users found the system easy to use without the support of researchers. Usability scores were considered to be "excellent" in both groups and no significant difference was found between sham and active groups showing effective blinding of the device (Active group: 93.7 (83.1-97.5); Sham group 90 (86.2-95) p = 0.79) and PGIC (Active group: 2 (1-2.75); Sham group 2 (1-2) p = 0.99) using an unpaired t-test or non-parametric statistical tests accordingly. The new Bluetooth-controlled wearable tDCS device is easy, safe to use and completely controlled by a smartphone app. This device is focused on women's health and will be tested as an alternative treatment for chronic pelvic pain and mood disturbance associated with menstrual cycles in further research.


Assuntos
Dismenorreia , Estimulação Transcraniana por Corrente Contínua , Humanos , Feminino , Adulto , Estimulação Transcraniana por Corrente Contínua/métodos , Estimulação Transcraniana por Corrente Contínua/instrumentação , Dismenorreia/terapia , Adulto Jovem , Autoadministração/instrumentação , Dispositivos Eletrônicos Vestíveis , Córtex Pré-Frontal/fisiologia
4.
Eur J Pediatr ; 183(7): 2899-2904, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38609653

RESUMO

School teachers are often inadequately prepared to use an adrenaline auto-injector (AAI), resulting in potentially dangerous treatment delays. The purpose of this study was to assess the observed competence, and self-reported confidence, of primary school teachers in the Republic of Ireland (RoI) to use an AAI. An evaluation of whether there was a link between confidence and competence was also assessed. Teachers from four primary schools in the RoI completed a questionnaire to assess their prior level of experience, training, and confidence levels with AAI administration. The four steps in administrating trainer AAI to a mannequin simulator were then assessed. A total of 61 teachers participated (out of a population of 80). The mean self-reported confidence was 1.82 out of 5 (SD = 0.96). There was no significant difference in confidence between trained and untrained participants (U = 240.5, NS). Participants who had received AAI administration training performed significantly more of the steps correctly (mean = 3.85, SD = 0.95) as compared to those who had received no training (mean = 2.97, SD = 1.10; U = 180.5, p = 0.008). There was no correlation between confidence in administrating AAI and the percentage of steps in the procedure performed correctly (rho = -0.17, NS).  Conclusion: Improvements in readiness to administer AAIs can be achieved through the application of more effective approaches to teaching clinical skills, changes to school policies and practices, and consideration of the design of AAIs in order to make their operation safer and simpler. It is important that teachers have the confidence and competence to safely administer an AAI. What is Known: • Poor ability in adrenaline auto-injector use seen across population groups-healthcare professionals, patients, carers, and school staff • Training in the use of adrenaline auto-injectors has positive impact on competency What is New: • Irish school teachers show poor levels of competency in adrenaline auto-injector use • No observed correlation between reported confidence and competency.


Assuntos
Epinefrina , Professores Escolares , Humanos , Epinefrina/administração & dosagem , Irlanda , Feminino , Masculino , Manequins , Inquéritos e Questionários , Adulto , Autoadministração/instrumentação , Anafilaxia/tratamento farmacológico , Instituições Acadêmicas , Competência Profissional , Criança , Injeções Intramusculares/instrumentação , Capacitação de Professores/métodos , Pessoa de Meia-Idade
5.
Ther Deliv ; 14(4): 259-268, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37435652

RESUMO

Background: The Sensoready® pen is intended for self-administration of subcutaneous 20 mg ofatumumab at home. This human factors summative study assessed the usability of the Sensoready pen in relapsing multiple sclerosis patients. Methods: 32 patients (injection-experienced [n = 17] and injection-naive [n = 15]) across five locations in the USA were asked to complete two simulated injections using the Sensoready pen. Results: In the first and second simulated injections, 90.6 and 96.9% of patients, respectively, successfully delivered a full dose, while 81.3 and 84.4%, respectively, successfully performed the injection without any use errors. Conclusion: The Sensoready pen is safe and effective for its intended use by intended users and in the intended use environment. This pen has a low harm potential and high injection success rate in patients, even without prior training or experience.


Assuntos
Anticorpos Monoclonais Humanizados , Esclerose Múltipla , Autoadministração , Humanos , Esclerose Múltipla/tratamento farmacológico , Anticorpos Monoclonais Humanizados/administração & dosagem , Autoadministração/instrumentação
6.
J Drugs Dermatol ; 21(2): 162-171, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35133113

RESUMO

BACKGROUND: Bimekizumab is a monoclonal IgG1 antibody that selectively inhibits interleukin (IL)-17F in addition to IL-17A. OBJECTIVES: To assess patients' ability to self-inject bimekizumab subcutaneously using a 1 mL safety syringe or auto-injector. METHODS: DV0002 and DV0006 were sub-studies of BE BRIGHT, a multicenter, phase 3 open-label extension study. Patients with moderate to severe plaque psoriasis received bimekizumab 320 mg (2x160 mg injections) every 4 or 8 weeks and were randomized 1:1 to the safety syringe or the auto-injector. The ability of patients to safely and effectively self-inject bimekizumab was assessed at 8 weeks (primary endpoint) and immediately after self-injection training at Baseline (secondary endpoint). Patient experience was evaluated using the pain visual analog scale (VAS; 0–100 mm; 100 being worst pain), and the Self-Injection Assessment Questionnaire (SIAQ; 0–10; 10 being most positive experience). RESULTS: All evaluable patients in DV0002 (n=125) and DV0006 (n=86) safely and effectively self-injected bimekizumab at Week 8. All evaluable patients in DV0002 who used the safety syringe (n=64) and 97.1% (n=66/68) who used the auto-injector, as well as all evaluable DV0006 patients (n=88) also self-injected bimekizumab safely and effectively at Baseline. Median VAS scores were low (range: 7.0–20.0), and median pre-injection and post-injection SIAQ scores were high (range: 5.8–10.0 and 7.1–10.0, respectively) across both devices, sub-studies, and timepoints. CONCLUSIONS: Both devices provide a safe and effective option for patients to self-administer bimekizumab. Furthermore, patients reported a positive self-injection experience. TRIAL REGISTRATION: NCT03766685 J Drugs Dermatol. 2022;21(2):162-171. doi:10.36849/JDD.6274THIS ARTICLE HAD BEEN MADE AVAILABLE FREE OF CHARGE. PLEASE SCROLL DOWN TO ACCESS THE FULL TEXT OF THIS ARTICLE WITHOUT LOGGING IN. NO PURCHASE NECESSARY. PLEASE CONTACT THE PUBLISHER WITH ANY QUESTIONS.


Assuntos
Anticorpos Monoclonais Humanizados , Psoríase , Autoadministração/instrumentação , Anticorpos Monoclonais Humanizados/administração & dosagem , Método Duplo-Cego , Humanos , Psoríase/diagnóstico , Psoríase/tratamento farmacológico , Índice de Gravidade de Doença , Resultado do Tratamento
8.
J Obstet Gynaecol ; 41(8): 1210-1215, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33645407

RESUMO

A randomised controlled trial was conducted. The primary objective was to evaluate the efficacy of a pillbox for increasing iron supplement compliance by comparing the proportion of pregnant women who had no remaining iron tablets between pregnant women attending ANC who were given a pillbox to use and women with no pillbox in four-week period between ANC visits. The secondary objective was to evaluate the reasons for poor compliance and possible factors associated with the non-compliance. One hundred and ninety pregnant women were enrolled, 95 participants were randomised into each of the groups. The proportion of pregnant women who had no remaining iron tablets at the end was statistically significantly lower in the pillbox group than in the control group [53.3% and 23.1%, respectively, p < .001, RR2.308 (95% CI 1.515 - 3.517)]. The most common reason given for having of iron tablets remaining was forgetfulness. The visual analog scale (VAS) scores indicated that patient's responsibility feeling, duration of sleep each day and presence of a handicapped or small child in care significantly influenced the proportion of pregnant women who had remaining iron tablets at the end in both groups. We concluded that a pillbox was found to be an effective tool for improving pregnant women's compliance with taking their iron supplements.IMPACT STATEMENTWhat is already known about this subject? Antenatal care (ANC) influences maternal and neonatal outcomes. The incidence of anaemia in pregnant women is reported to be around 42% and approximately 50% result from iron deficiency. Maternal anaemia increases the risk of foetal low birth weight, preterm birth, perinatal mortality, stillbirth and maternal mortality.What do the results of this study add? The 28-compartment pillbox is effective for improving iron supplement compliance in healthy pregnant women. Forgetfulness is the most common reason given for having remaining iron tablets. The lower score on the visual analog scale of patient's feeling of responsibility, long duration of sleep a day and the presence of a handicapped or small child in their care were significantly associated with having remaining iron tablets.What are the implications are of these finding for clinical practice and/or further research? The 28-compartment pillbox can be implied to routine antenatal care for improving iron supplement compliance in healthy pregnant women. Health care providers should be reminded to encourage compliance with iron supplement prescription in pregnant women who are at risk of poor compliance as indicated by low VAS of the patient's feeling of responsibility, long duration of sleep in a day and pregnant women who have responsibility to take care of handicapped or small children.


Assuntos
Suplementos Nutricionais , Compostos de Ferro/administração & dosagem , Cooperação do Paciente/estatística & dados numéricos , Cuidado Pré-Natal/estatística & dados numéricos , Autoadministração/instrumentação , Adulto , Esquema de Medicação , Feminino , Humanos , Cooperação do Paciente/psicologia , Gravidez , Gestantes/psicologia , Cuidado Pré-Natal/métodos , Autoadministração/psicologia , Comprimidos
9.
Arch Dis Child ; 106(6): 558-563, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32948514

RESUMO

OBJECTIVE: To assess the impact of anaphylaxis on health-related quality of life (HRQL) and self-efficacy in food-allergic patients undergoing in-hospital food challenge. DESIGN: Secondary analysis of a randomised controlled trial. SETTING: Specialist allergy centre. PATIENTS: Peanut-allergic young people aged 8-16 years. INTERVENTIONS: Double-blind, placebo-controlled food challenge to peanut, with HRQL and self-efficacy assessed using validated questionnaire, approximately 2 weeks prior to and 2 weeks after challenge. Where possible, anaphylaxis was treated with self-injected adrenaline (epinephrine). MAIN OUTCOME MEASURES: Change in HRQL and self-efficacy. RESULTS: 56 participants had reactions at food challenge, of whom 16 (29%) had anaphylaxis. Overall, there was an improvement in HRQL (mean 2.6 points (95% CI 0.3 to 4.8); p=0.030) and self-efficacy (mean 4.1 points (95% CI 2.4 to 5.9); p<0.0001), independent of whether anaphylaxis occurred. Parents also reported improved HRQL (mean 10.3 points (95% CI 5.9 to 14.7); p<0.0001). We found evidence of discordance between the improvement in HRQL and self-efficacy as reported by young people and that perceived by parents in their child. CONCLUSIONS: Anaphylaxis at food challenge, followed by self-administration of injected adrenaline, was associated with an increase in HRQL and self-efficacy in young people with peanut allergy. We found no evidence that the occurrence of anaphylaxis had a detrimental effect. Young people should be encouraged to self-administer adrenaline using their autoinjector device to treat anaphylaxis at in-hospital challenge. TRIAL REGISTRATION NUMBER: NCT02149719.


Assuntos
Alérgenos/efeitos adversos , Anafilaxia/tratamento farmacológico , Epinefrina/administração & dosagem , Hipersensibilidade a Amendoim/diagnóstico , Administração Oral , Adolescente , Alérgenos/administração & dosagem , Anafilaxia/imunologia , Anafilaxia/psicologia , Arachis/efeitos adversos , Criança , Estudos Cross-Over , Dessensibilização Imunológica/métodos , Método Duplo-Cego , Feminino , Hospitais , Humanos , Injeções Intramusculares , Masculino , Nozes/efeitos adversos , Hipersensibilidade a Amendoim/tratamento farmacológico , Hipersensibilidade a Amendoim/imunologia , Hipersensibilidade a Amendoim/psicologia , Qualidade de Vida , Autoadministração/instrumentação , Autoeficácia , Resultado do Tratamento
10.
Health Qual Life Outcomes ; 18(1): 355, 2020 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-33148261

RESUMO

BACKGROUND: Patient-reported outcome (PRO) instruments provide robust and effective means of evaluating patients' treatment experience; however, none adequately cover experience using self-injection devices with enhanced features, such as an electromechanical autoinjector (e-Device). The aim of this study was to develop a PRO instrument that accurately assesses patient experience of using an e-Device and to evaluate its psychometric properties. METHODS: A mixed-methods approach was taken; two parallel, targeted literature reviews were conducted to identify relevant concepts and existing self-injection PRO instruments that could be adapted. Patient feedback obtained from two focus groups was used to inform initial instrument development. The pilot instrument was then administered in a multicenter, open-label, phase 3 clinical study in which patients self-injected certolizumab pegol using an e-Device, to gather evidence of its psychometric qualities. Exit interviews were conducted with a sub-sample of patients enrolled in the study to confirm the appropriateness and clarity of the items included and cognitively debrief the instrument. Confirmatory factor analysis (CFA) was conducted on all items, and each domain's internal consistency was measured using Cronbach's ɑ. RESULTS: The literature searches identified several e-Device-specific concepts related to device features, device function, side effects/reactions/pain, confidence, and interference/convenience in daily life. Seven existing PRO instruments were identified. The Self-Injection Assessment Questionnaire (SIAQ), containing pre- and post-injection questionnaire modules, was selected as most suitable and adapted using feedback from 19 patients in the two focus groups to form the pilot Assessment of Self-Injection (ASI) questionnaire. CFA resulted in some changes to the grouping of items in the post-injection module domains following psychometric evaluation of the ASI. Internal consistency was satisfactory for all pre- and post-injection domains (ɑ > 0.8). Cognitive debriefing results from 12 patient exit interviews confirmed the ASI's appropriateness and clarity. CONCLUSIONS: The ASI was developed iteratively with patient input and was evaluated in its intended clinical context of use. Psychometric analyses indicated promising cross-sectional results; the ASI was well understood and considered relevant by patients self-injecting using the e-Device, suggesting that it could be used in real-world settings to aid with clinical decision making. TRIAL REGISTRATION: NCT03357471.


Assuntos
Injeções/instrumentação , Medidas de Resultados Relatados pelo Paciente , Autoadministração/instrumentação , Adulto , Ensaios Clínicos Fase III como Assunto , Feminino , Grupos Focais , Humanos , Injeções/psicologia , Masculino , Pessoa de Meia-Idade , Estudos Multicêntricos como Assunto , Projetos Piloto , Psicometria/métodos , Pesquisa Qualitativa , Reprodutibilidade dos Testes , Autoadministração/psicologia
12.
BMC Pulm Med ; 20(1): 222, 2020 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-32819337

RESUMO

BACKGROUND: Inhalation therapy is the backbone of asthma and COPD control. However, inhaler adherence and device mishandling continue to be a problem in real life. Some studies have shown that using a patient-preferred inhaler may reduce device handling errors and improve adherence to prescribed chronic inhaler drug therapy. The aim of this study was to compare the preferences for commonly used inhaler devices in Germany in patients with chronic obstructive respiratory disease. We also pursued the question which properties of an inhaler device are particularly important to the user and what effects age, gender and type of disease (asthma or COPD) may have on device preference and handling errors. METHODS: Prospective, open-label cross-sectional study in which 105 patients with asthma (58%) or COPD (42%) participated. Validated checklists were used to objectively assess inhaler technique and errors with 10 different placebo devices. For each device, patients were asked to test the handling, to assess the device properties and to name the device that they would most or least prefer. RESULTS: Across the 10 placebo inhaler devices tested, patients needed an average of 1.22 attempts to error-free use. The device with the lowest mean number of attempts was the Turbohaler® (1.02), followed by the Nexthaler® (1.04), the Diskus® (1.07) and the Spiromax® (1.10). Patients over 60 years vs. younger age (p = 0.002) and COPD vs. asthma patients (p = 0.016) required more attempts to ensure correct use. 41% of the study participants chose one of the devices they already used as the most preferred inhaler. Overall, 20% opted for the Spiromax®, 15% for the Nexthaler® and 14% for the Turbohaler® or a pMDI. The least preferred device was the Elpenhaler® (0%). From a selection of 7 predefined inhaler attributes, patients stated easy handling as the most important for them. This was followed by short inhalation time and low inhalation resistance. CONCLUSIONS: Patient preference may vary between inhaler devices. The lowest number of attempts to error-free use was reported for the Turbohaler® and the Nexthaler®. The Spiromax® and the Nexthaler® achieved the best overall ratings and were the devices most preferred by patients.


Assuntos
Asma/tratamento farmacológico , Nebulizadores e Vaporizadores , Preferência do Paciente , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Adolescente , Adulto , Asma/psicologia , Estudos Transversais , Desenho de Equipamento , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/psicologia , Autoadministração/instrumentação , Autoadministração/normas , Adulto Jovem
14.
Pediatr Rheumatol Online J ; 18(1): 64, 2020 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787934

RESUMO

BACKGROUND: Methotrexate is the most commonly used disease-modifying antirheumatic drug recommended in the treatment of juvenile idiopathic arthritis. It can be administered orally or subcutaneously, the latter method is associated with fewer side effects and higher drug bioavailability. Nevertheless, the pain associated with injection is a considerable drawback of this treatment option in the pediatric population. Currently, there are two single-use subcutaneous injection devices available: the prefilled syringe and the prefilled pen. This prospective, two-sequence crossover study aimed to compare ease of use, frequency of therapy side effects, injection-site pain and parent/patient preference of those methotrexate parenteral delivery systems. METHODS: Twenty-three patients with juvenile idiopathic arthritis, already treated with subcutaneous methotrexate in the form of prefilled syringe in the period October 2018 - April 2019 completed a questionnaire evaluating their experience with this device. Subsequently, children received a one-month supply of pen autoinjector and completed the same questionnaire, regarding their experience with the new methotrexate delivery system. If the patient was not performing the injections himself the questionnaires were completed by the caregiver administrating MTX. The results obtained in both questionnaires were compared using the Wilcoxon matched-pairs signed-rank test. RESULTS: 82,6% patients and their caregivers voted for the prefilled pen as their preferred method of subcutaneous methotrexate administration. Moreover, the injection with the prefilled pen was reported as less painful in comparison to the prefilled syringe (p < 0.01). Side effects of methotrexate were less pronounced after the prefilled pen treatment, this difference was most prominent regarding gastrointestinal adverse events associated with the injection (p < 0.01). CONCLUSION: Administration of methotrexate using the pen device is a promising way of subcutaneous methotrexate delivery in children with juvenile idiopathic arthritis, as the injection is less painful and associated with fewer side effects.


Assuntos
Artrite Juvenil , Injeções Subcutâneas , Metotrexato , Dor Processual , Autoadministração , Seringas , Antirreumáticos/administração & dosagem , Antirreumáticos/farmacocinética , Artrite Juvenil/tratamento farmacológico , Artrite Juvenil/psicologia , Disponibilidade Biológica , Criança , Equipamentos Descartáveis , Sistemas de Liberação de Medicamentos/instrumentação , Feminino , Humanos , Injeções Subcutâneas/efeitos adversos , Injeções Subcutâneas/instrumentação , Injeções Subcutâneas/métodos , Masculino , Metotrexato/administração & dosagem , Metotrexato/farmacocinética , Avaliação de Resultados em Cuidados de Saúde , Dor Processual/etiologia , Dor Processual/psicologia , Satisfação do Paciente , Projetos Piloto , Autoadministração/efeitos adversos , Autoadministração/instrumentação , Autoadministração/métodos , Inquéritos e Questionários , Seringas/efeitos adversos , Seringas/classificação
15.
Curr Opin Allergy Clin Immunol ; 20(5): 474-481, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32657793

RESUMO

PURPOSE OF REVIEW: Epinephrine is the only life-saving treatment of anaphylaxis. Prescription and administration rates of self-injectable epinephrine are generally low. It is unclear whether this is because of availability, low prescription rates, fear of using epinephrine, or a combination of these issues. RECENT FINDINGS: This review focuses on what self-injectable epinephrine devices (SIED), such as auto-injectors and prefilled syringes, are preferred by patients and healthcare professionals (HCP). Our findings suggest that a device's ease to use, proper and frequent training on its operability, and availability have an impact on preferences and adherence to treatment with SIEDs. After prescribing a patient with a SIED, clinicians should emphasize its use in anaphylaxis, educate patients/caregivers to identify anaphylaxis and on how to use the SIED, and encourage constant practicing with training devices. SUMMARY: Epinephrine is the sole recommended anaphylaxis treatment and SIEDs are of critical usefulness in the community setting. Further studying of these devices is needed to optimize education for HCPs and patients and their accessibility to SIEDs.


Assuntos
Anafilaxia/tratamento farmacológico , Epinefrina/administração & dosagem , Conhecimentos, Atitudes e Prática em Saúde , Cooperação do Paciente , Médicos/psicologia , Adulto , Assistência ao Convalescente/métodos , Anafilaxia/psicologia , Cuidadores/psicologia , Criança , Humanos , Injeções Intramusculares/instrumentação , Educação de Pacientes como Assunto/métodos , Autoadministração/instrumentação , Resultado do Tratamento
16.
Curr Opin Allergy Clin Immunol ; 20(4): 421-427, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32590510

RESUMO

PURPOSE OF REVIEW: New biological agents, in addition to the well-established omalizumab, have been nowadays introduced into clinical practice for severe asthma. This suggested the possibility of an at-home self-administration, as currently happening for other biological agents for immune-mediated diseases. RECENT FINDINGS: In the very recent years, there were structured clinical trials investigating the self at home administrations of biologicals for severe asthma, showing with different principles, a possible advantage and convenience for the patient, and a socioeconomic saving. SUMMARY: The literature analysis currently shows that the at-home self-administration of biologicals for severe asthma is a promising approach to improve the treatment of such disease.


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Fatores Biológicos/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Asma/imunologia , Humanos , Injeções Subcutâneas/instrumentação , Omalizumab/administração & dosagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Autoadministração/instrumentação , Autoadministração/métodos , Índice de Gravidade de Doença , Seringas , Resultado do Tratamento
17.
Expert Opin Drug Deliv ; 17(7): 1041-1048, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32543910

RESUMO

OBJECTIVE: The Aluetta™ reusable pen device and instructions for use (IFU) for growth hormone (r-hGH; Saizen®, Merck KGaA, Darmstadt, Germany) administration were tested for Human-Factors Usability, to ensure it could be used safely and effectively by the intended users in the intended use environment. RESEARCH DESIGN AND METHODS: Usability testing was conducted under simulated conditions in three groups of participants: pediatric or adult patients with growth hormone deficiency (GHD), participants without GHD, and healthcare professionals (HCPs). The testing comprised a 45-minute training session, a 2-hour testing session, and a participant-feedback session. RESULTS: Twenty-six participants completed the training session and performed all critical tasks related to the pen use across three scenarios. The most difficult tasks were related to the preparation, checking, and maintenance of the device; only 8% of use errors occurred during tasks related to the injection process. Eighty-five percent considered the pen safe and effective to use without further modifications and the training to be clear and effective. CONCLUSIONS: The pen device and associated materials benefited from Human Factors Engineering throughout the development process. These evaluations show that patients and HCPs could safely and effectively use the pen device, and the IFU and training were clear and effective.


Assuntos
Ergonomia , Hormônio do Crescimento Humano/administração & dosagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Injeções/instrumentação , Masculino , Pessoa de Meia-Idade , Proteínas Recombinantes/administração & dosagem , Autoadministração/instrumentação
18.
J Int Med Res ; 48(5): 300060520926019, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32436421

RESUMO

There are several situations such as medical emergencies and incidents involving mass casualties where drugs and antidotes have to be administered immediately along with other first aid at the site of the event. Self-administration by the affected person or by a companion is required as a life-saving measure. Autoinjector devices (AIDs) are useful for the rapid administration of drugs and antidotes and they can also be used by those who have not been medically trained. This makes them very convenient for emergency and mass casualty management. An AID has a drug cartridge with an embedded needle for subcutaneous or intramuscular injection, which is usually painless. The drugs are delivered slowly by the AID across a large area in the muscle, which increases the absorption and the drug effects are equal to that of intravenous administration. A variety of AIDs are available, such as atropine and pralidoxime for nerve agent poisoning, epinephrine for anaphylactic shock and allergy, diazepam for seizures, sumatriptan for migraine, amikacin for antibacterial treatment, buprenorphine for pain relief and monoclonal antibodies for a variety of diseases. This review describes the published peer-reviewed literature identified by online searches of journal databases.


Assuntos
Emergências , Tratamento de Emergência/instrumentação , Incidentes com Feridos em Massa , Autoadministração/instrumentação , Antídotos/administração & dosagem , Atropina/administração & dosagem , Humanos , Injeções Intramusculares/instrumentação , Injeções Subcutâneas/instrumentação , Fatores de Tempo
19.
Anal Bioanal Chem ; 412(12): 2785-2793, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32100074

RESUMO

Epinephrine autoinjectors (EAIs) are important first aid medications for treating anaphylaxis. A 10-fold price increase over the past 12 years and evidence that expired EAIs may still contain significant doses of available epinephrine have motivated interest in the efficacy of expired EAIs as treatments of last resort. Degradation of expired EAIs, which can be caused by improper storage conditions, results in various degrees of discoloration of the epinephrine solution. Previous studies have determined that significant epinephrine remains available in expired EAIs, but these have only considered EAIs that show no discoloration. Here, we investigate the potential for colorimetric estimation of available epinephrine dose based on the degree of discoloration in expired EAIs. The correlation of available epinephrine dose and time since expiration date was poor (r = - 0.37), as determined by an industry standard UHPLC protocol. Visible absorbance of the samples integrated across the range 430-475 nm correlated well with available epinephrine dose (r = - 0.71). This wavelength corresponds to the blue channel of a typical smartphone camera Bayer filter. Smartphone camera images of the EAI solutions in various illumination conditions were analyzed to assign color indices representing the degree of discoloration. Color index of the samples showed similar correlation (|r| > 0.7) with available epinephrine dose as that of visible spectrophotometry. Smartphone imaging colorimetry is proposed as a potential point-of-use epinephrine dose estimator for expired and degraded EAIs. Graphical abstract.


Assuntos
Anafilaxia/tratamento farmacológico , Diagnóstico por Imagem/métodos , Estabilidade de Medicamentos , Armazenamento de Medicamentos/normas , Epinefrina/análise , Autoadministração/métodos , Smartphone/instrumentação , Epinefrina/administração & dosagem , Humanos , Injeções Intramusculares , Autoadministração/instrumentação
20.
Clin Ther ; 42(1): 94-107.e5, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31879033

RESUMO

PURPOSE: The proprotein convertase subtilisin/kexin type 9 inhibitor alirocumab has produced significant reductions in LDL-C at a dose of 300 mg q4w administered as 2 separate 150-mg injections via a 1-mL autoinjector (AI). A recently developed 2-mL device (SYDNEY) permits the administration of a single 300mg dose of alirocumab. METHODS: We assessed the usability and product technical complaints (PTCs) reported by patients using the 2-mL SYDNEY device in unsupervised settings, adverse events, and effects on LDL-C, in a multicenter, randomized, open-label, 16-week study conducted in the United States. For their first dose, 69 patients with hypercholesterolemia despite receiving statin with or without other lipid-lowering therapy randomly received supervised, self-administered alirocumab 300 mg via 1 × 300 mg injection with the SYDNEY device (n = 35) or 2 × 150-mg injections with the currently approved AI (n = 34). All continuing patients subsequently received unsupervised, self-administered alirocumab 300 mg q4w using the SYDNEY device at weeks 4, 8, and 12. The primary end point was the proportion of SYDNEY device-associated PTCs related to the use of the unsupervised injections. FINDINGS: Baseline characteristics between the study arms varied only in a higher percentage of males being randomized to the study arm using the SYDNEY device (74.3%) compared with the AI arm (44.1%). A single PTC was reported during the unsupervised injections (0.5%; 1 of 196 injections; 95% CI, 0.0%-3.2%). This event was classified as patient related as opposed to device related. No PTCs occurred during supervised injections. Mean LDL-C reductions from baseline at week 4 were 66.2% with SYDNEY and 51.2% with the AI; after adjustment for sex differences between groups, mean LDL-C reductions were 63.5% and 53.9%, respectively. LDL-C reductions persisted for 16 weeks. The most common adverse event was upper respiratory tract infection (3 with SYDNEY and 0 with the AI during weeks 0-4). IMPLICATIONS: The SYDNEY device allowed for a single 2-mL injection of alirocumab 300 mg, providing substantial LDL-C reductions with no new product technical issues or no new safety concerns compared with the currently marketed 1-mL AI device. In conclusion, the 2-mL SYDNEY device provides patients with the possibility of injecting the 300-mg alirocumab dose as a single injection. ClinicalTrials.gov identifier: NCT03415178.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Hipercolesterolemia/tratamento farmacológico , Hipolipemiantes/administração & dosagem , Injeções Subcutâneas/instrumentação , Inibidores de PCSK9 , Autoadministração/instrumentação , Idoso , LDL-Colesterol/sangue , Feminino , Humanos , Hipercolesterolemia/sangue , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA