Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 236
Filtrar
1.
J Thorac Cardiovasc Surg ; 161(2): 545-558, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33070936

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and hemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/normas , Doenças das Valvas Cardíacas/patologia , Valvas Cardíacas/patologia , Valvas Cardíacas/cirurgia , Hemodinâmica/fisiologia , Humanos
3.
Magn Reson Imaging ; 68: 18-29, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31981709

RESUMO

PURPOSE: We exploited 4-dimensional flow magnetic resonance imaging (4D Flow), combined with a standardized in vitro setting, to establish a comprehensive benchmark for the systematic hemodynamic comparison of surgical aortic bioprosthetic valves (BPVs). MATERIALS AND METHODS: 4D Flow analysis was performed on two small sizes of three commercialized pericardial BPVs (Trifecta™ GT, Carpentier-Edwards PERIMOUNT Magna and Crown PRT®). Each BPV was tested over a clinically pertinent range of continuous flow rates within an in vitro MRI-compatible system, equipped with pressure transducers. In-house 4D Flow post-processing of the post-valvular velocity field included the quantification of BPV effective orifice area (EOA), transvalvular pressure gradients (TPG), kinetic energy and viscous energy dissipation. RESULTS: The 4D Flow technique effectively captured the 3-dimensional flow pattern of each device. Trifecta exhibited the lowest range of velocity and kinetic energy, maximized EOA (p < 0.0001) and minimized TPGs (p ≤ 0.015) if compared with Magna and Crown, these reporting minor EOA difference s (p ≥ 0.042) and similar TPGs (p ≥ 0.25). 4D Flow TPGs estimations strongly correlated against ground-truth data from pressure transducers; viscous energy dissipation proved to be inversely proportional to the fluid jet penetration. CONCLUSION: The proposed 4D Flow analysis pinpointed consistent hemodynamic differences among BPVs, highlighting the not negligible effect of device size on the fluidynamic outcomes. The efficacy of non-invasive 4D Flow MRI protocol could shed light on how standardize the comparison among devices in relation to their actual hemodynamic performances and improve current criteria for their selection.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Benchmarking , Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Imageamento por Ressonância Magnética , Desenho de Prótese/normas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Cinética
4.
Int J Cardiol ; 300: 80-86, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31740140

RESUMO

BACKGROUND: The use of bioprostheses for surgical aortic valve replacement increased substantially within the last years. In case of prosthesis failure, re-SAVR is standard of care, whereas valve-in-valve deployment of a transfemoral transcatheter aortic valve prosthesis (VinV-TFAVI) has recently emerged as an alternative. We sought to evaluate early safety, clinical efficacy, and all-cause 1-year-mortality of VinV-TFAVI and redo surgery for failing aortic bioprostheses (re-SAVR). METHODS AND RESULTS: Patients receiving either VinV-TFAVI (n = 147) or re-SAVR (n = 111) for a degenerated aortic bioprosthesis between 01/2006 and 05/2017 were included in this analysis. All-cause 1-year mortality was the primary outcome measure. Early safety and clinical efficacy according to VARC-2 endpoint definitions were evaluated at 30 days. Baseline characteristics differed significantly between both groups including age, STS-PROM, and incidence of relevant comorbidities. Re-stenosis was the predominant mode of failure in 45.9% of re-SAVR and 63.1% of VinV-TFAVI patients. The rate of "early safety" endpoints was lower with VinV-TFAVI (17.7% vs. 64.9%, p < 0.01), the rate of "clinical efficacy" endpoints was lower, e.g. better with re-SAVR (53.1% vs. 32.4%, p < 0.01). All-cause 1-year-mortality (VinV-TFAVI 8.8% vs re-SAVR 9.9%, p = 0.84) was not different. Treatment strategy was not associated with 1-year-mortality in a Cox regression analysis. The incidence of prosthesis-patient-mismatch was higher in VinV-TFAVI compared to re-SAVR. CONCLUSION: VinV-TFAVI represents a viable alternative for treatment of degenerated aortic bioprostheses in patients at increased surgical risk. However, in patients at low risk for reoperation, a better clinical efficacy and acceptable safety may favour re-SAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/normas , Artéria Femoral/cirurgia , Próteses Valvulares Cardíacas/normas , Falha de Prótese , Reoperação/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Bioprótese/tendências , Estudos de Coortes , Feminino , Próteses Valvulares Cardíacas/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese/tendências , Reoperação/tendências , Substituição da Valva Aórtica Transcateter , Falha de Tratamento , Resultado do Tratamento
5.
Anatol J Cardiol ; 22(4): 172-176, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31584434

RESUMO

OBJECTIVE: The ideal alternative for tricuspid valve replacement (TVR) in patients with severe isolated tricuspid regurgitation remains unclear. The aim of the present study was to retrospectively investigate the outcomes of using bioprosthetic and mechanical valves at the tricuspid position. METHODS: A total of 98 consecutive patients without left-side cardiac disease or history of heart surgery who underwent first-time TVR between January 2010 and March 2017 at the West China Hospital, China were included in the study. Patient data, including all-cause death and need for tricuspid valve reoperation as the main end points, were retrospectively evaluated. RESULTS: A total of 76 patients were enrolled into the study. The mean follow-up period was 43.3±21.9 (10-87) months. The mean age of the patients was 45.7±13.4 years. The study comprised 32.9% of male patients. During the follow-up period, 4, 3, 12, and 3 cases of death, reoperation, prosthesis dysfunctions, and prosthesis-related thrombosis were noted, respectively. Biological and mechanical valves were used in 56.6% and 43.4% of the patients, respectively. However, there was no significant difference between mechanical and biological valves with respect to echocardiographic date and survival, reoperation, prosthetic valve dysfunction, and thromboembolism rate. CONCLUSION: TVR is not a very high-risk procedure in patients with isolated tricuspid regurgitation, and the decision for prosthesis implantation in TVR should be made on an individual basis according to suitable clinical judgment.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide , Adulto , Bioprótese/normas , Estudos de Casos e Controles , Ecocardiografia , Feminino , Seguimentos , Próteses Valvulares Cardíacas/normas , Implante de Prótese de Valva Cardíaca/normas , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Valva Tricúspide/cirurgia
6.
Rev. bras. cir. plást ; 34(3): 368-377, jul.-sep. 2019. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-1047157

RESUMO

Introdução: Com o objetivo de obter lipoenxerto autógeno e injetável de tecido ressecado em dermolipectomias, este estudo propõe um novo método para colheita e processamento do tecido adiposo, através de um dispositivo fragmentador específico. O principal objetivo foi estabelecer uma análise comparativa das características de qualidade e viabilidade do novo lipofragmentado em relação ao já conhecido lipoaspirado, amplamente aceito como fonte viável de lipoenxerto. Ensaios in vivo e in vitro foram delineados para avaliar o comportamento biológico das amostras, a fim de orientar novos e possíveis estudos em humanos com aplicações clínicas. Métodos: Uma paciente pós-bariátrica que foi submetida a dermolipectomia abdominal teve sua peça cirúrgica ressecada e dividida em quatro partes que foram submetidas a Lipoaspiração e Lipofragmentação, sem e com infiltração prévia. Todas as amostras foram submetidas a centrifugação e então distribuídas para os ensaios que envolveram avaliação histológica, imunohistoquímica, citometria de fluxo, cultura celular e ainda a injeção de xenoenxerto no dorso de 10 ratos Wistar, retirados após seis semanas para avaliação de massa, volume e características histológicas. Resultados: As amostras de gordura fragmentada, seca e infiltrada, mostraram características estruturais e comportamento biológico semelhantes aos das amostras de lipoaspirado. Conclusões: A fragmentação da gordura transformou o tecido celular subcutâneo das dermolipectomias em uma nova variante de lipoenxerto injetável e viável, com características biológicas semelhantes àquelas do lipoaspirado tradicional. Embora ainda preliminares, nossos resultados embasam a realização de novas investigações buscando otimizar a técnica com vistas ao aprimoramento da enxertia gordurosa e suas possíveis aplicações na medicina regenerativa.


Introduction: Aiming to obtain autogenous and injectable lipografts from resected tissues in dermolipectomies, this study proposes a new method for harvesting and processing adipose tissue through a specific fragmenting device. The main objective was to establish a comparative analysis of the quality and viability characteristics of the new lipofragmentation technique and those of the well-known liposuction technique, widely accepted as a viable source of fat grafting. In vivo and in vitro assays were designed to evaluate the biological behavior of the samples to guide new and possible human studies with clinical applications. Methods: A post-bariatric patient who underwent abdominal dermolipectomy had her surgical specimen resected, which was divided into four parts that underwent liposuction and lipofragmentation, with and without prior infiltration. All samples were centrifuged and distributed for assays with assessments involving histological analysis, immunohistochemistry, flow cytometry, cell culture, and xenograft injection on the back of 10 Wistar rats, which was evaluated after six weeks for mass, volume, and histological features. Results: The structural characteristics and biological behaviors of fragmented, dry, and infiltrated fat samples were similar to those of liposuction samples. Conclusions: Fat fragmentation transformed the subcutaneous cellular tissue of dermolipectomies into a new, viable injectable lipograft variant, with biological characteristics similar to those of traditional liposuction. Although still preliminary, our results support further investigations to optimize the technique and improve fat grafting and its possible applications in regenerative medicine.


Assuntos
Humanos , Feminino , Adulto , Ratos , História do Século XXI , Manejo de Espécimes , Cirurgia Plástica , Transplante Autólogo , Bioprótese , Tecido Adiposo , Procedimentos de Cirurgia Plástica , Sobrevivência de Enxerto , Manejo de Espécimes/métodos , Cirurgia Plástica/métodos , Transplante Autólogo/métodos , Bioprótese/normas , Tecido Adiposo/anatomia & histologia , Procedimentos de Cirurgia Plástica/métodos
7.
J Thorac Cardiovasc Surg ; 158(4): 1041-1054, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31084981

RESUMO

Intraoperative surgical prosthetic heart valve (SHV) choice is a key determinant of successful surgery and positive postoperative outcomes. Currently, many controversies exist around the sizing and labeling of SHVs rendering the comparison of different valves difficult. To explore solutions, an expert Valve Labelling Task Force was jointly initiated by the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and the American Association for Thoracic Surgery (AATS). The EACTS-STS-AATS Valve Labelling Task Force, comprising cardiac surgeons, cardiologists, engineers, regulators and representatives from the International Organization for Standardization (ISO), and major valve manufacturers, held its first in-person meeting in February 2018 in Paris, France. This article was derived from the meeting's discussions. The Task Force identified the following areas for improvement and clarification: reporting of physical dimensions and characteristics of SHVs determining and labeling of SHV size, in vivo and in vitro testing, and reporting of SHV hemodynamic performance and thrombogenicity. Furthermore, a thorough understanding of the regulatory background and the role of the applicable ISO standards, together with close cooperation between all stakeholders (including regulatory and standard- setting bodies), is necessary to improve the current situation. Cardiac surgeons should be provided with appropriate information to allow for optimal SHV choice. This first article from the EACTS-STS-AATS Valve Labelling Task Force summarizes the background of SHV sizing and labeling and identifies the most important elements where further standardization is necessary.


Assuntos
Bioprótese/normas , Cardiologia/normas , Qualidade de Produtos para o Consumidor/normas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Rotulagem de Produtos/normas , Desenho de Prótese/normas , Tomada de Decisão Clínica , Consenso , Análise de Falha de Equipamento/normas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Seleção de Pacientes , Falha de Prótese , Sociedades Médicas
8.
Int J Cardiol ; 281: 113-118, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-30732866

RESUMO

OBJECTIVES: Bioprosthetic pulmonary valve conduits have been reported with an increased risk of endocarditis. Thrombus formation is considered as source of these serious and life-threatening infections. We reviewed a series of explanted valved pulmonary conduits for histological evidence for thrombus formation. MATERIALS AND METHODS: Explanted bioprosthetic pulmonary valves were fixed in formalin and embedded in paraffin or in methylmethacrylate. Standard staining as well as immunohistochemical staining techniques were applied. Native pulmonary valves of German domestic pigs served as controls. RESULTS: 47 valved pulmonary conduits (Hancock n = 23, Homograft n = 7, Contegra n = 7, Melody n = 7, other n = 3) were analyzed histologically. Average time of implantation had been 63 months (6 to 342 months). Indications for explantation included significant obstruction (n = 45), regurgitation (n = 7), and/or endocarditis (n = 6). In 44/47 (93%) specimen, we found accumulation of thrombotic material at the basis of the semilunar valve sinus to a variable degree. 11 patients had been treated with antiplatelet agents, 2 had received anticoagulants at the time of explantation. There was no suspicion of thrombus formation clinically or echocardiographically prior to explantation in any of the patients. Control porcine pulmonary valves (n = 5) did not show any evidence of accumulation of thrombotic material. CONCLUSIONS: In a large series of explanted valved pulmonary conduits, formation of subclinical, mostly non-infectious thrombotic material was an almost ubiquitous finding. We speculate that high incidence of endocarditis in bioprosthetic valves may in part be explained by thrombus apposition at the basis of conduit valve sinus.


Assuntos
Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Trombose/patologia , Adolescente , Adulto , Animais , Bioprótese/normas , Criança , Pré-Escolar , Feminino , Próteses Valvulares Cardíacas/normas , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Valva Pulmonar/patologia , Estenose da Valva Pulmonar/patologia , Suínos , Trombose/etiologia , Adulto Jovem
9.
Int J Cardiol ; 268: 170-175, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30041783

RESUMO

BACKGROUND: The durability of TAVR prostheses has come under major scrutiny since the move towards lower risk patients. We sought to compare the rate of structural valve deterioration (SVD) over time between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). METHODS: We included all TAVR and SAVR patients (age ≥ 75 years) that were performed in our centre from 2005 until 2015. Applying the internationally "agreed on" definitions of SVD, we surveyed all available serial echocardiographic follow-ups. RESULTS: We included 269 TAVR and 174 SAVR cases. Post-intervention, TAVR patients had lower mean and peak gradients but higher rate of mild aortic regurgitation. SAVR patients had longer follow-up (in months, SAVR: 53 (30, 85) Vs TAVR: 33.4 (23, 52)). SVD as per Valve Academic Research Consortium-2 (VARC-2) was similar between the two groups (TAVR 28% Vs SAVR 31%; P = 0.593) but moderate haemodynamic SVD (European Association of Percutaneous Cardiovascular Intervention (EAPCI) criteria) was more common among SAVR cases (TAVR 11.5% Vs SAVR 20.7%; P = 0.007). Using Kaplan-Meier estimates, the rate of SVD over time was not different between the two groups as per VARC-2 criteria but different when moderate haemodynamic SVD criteria were applied (Log Rank P = 0.022) in favour of TAVR. The mean gradient rose steadily over time but more so post-SAVR (ß = 0.52 ±â€¯0.24 in comparison to TAVR at every given time point; P = 0.032). CONCLUSION: Structural valve deterioration is common on long-term follow-up post-TAVR. The rate is similar to post-SAVR cases according to VARC-2 criteria but less according to the moderate haemodynamic SVD criteria.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Bioprótese/normas , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Desenho de Prótese/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Bioprótese/tendências , Feminino , Seguimentos , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Masculino , Desenho de Prótese/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências , Resultado do Tratamento
10.
Braz J Cardiovasc Surg ; 33(2): 122-128, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29898140

RESUMO

OBJECTIVE: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. METHODS: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). RESULTS: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. CONCLUSION: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Substituição da Valva Aórtica Transcateter/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ponte Cardiopulmonar/métodos , Constrição , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Esternotomia/métodos , Procedimentos Cirúrgicos sem Sutura/métodos , Fatores de Tempo , Resultado do Tratamento
11.
Circulation ; 137(24): 2635-2650, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29891620

RESUMO

The Academic Research Consortium (ARC)-2 initiative revisited the clinical and angiographic end point definitions in coronary device trials, proposed in 2007, to make them more suitable for use in clinical trials that include increasingly complex lesion and patient populations and incorporate novel devices such as bioresorbable vascular scaffolds. In addition, recommendations for the incorporation of patient-related outcomes in clinical trials are proposed. Academic Research Consortium-2 is a collaborative effort between academic research organizations in the United States and Europe, device manufacturers, and European, US, and Asian regulatory bodies. Several in-person meetings were held to discuss the changes that have occurred in the device landscape and in clinical trials and regulatory pathways in the last decade. The consensus-based end point definitions in this document are endorsed by the stakeholders of this document and strongly advocated for clinical trial purposes. This Academic Research Consortium-2 document provides further standardization of end point definitions for coronary device trials, incorporating advances in technology and knowledge. Their use will aid interpretation of trial outcomes and comparison among studies, thus facilitating the evaluation of the safety and effectiveness of these devices.


Assuntos
Bioprótese/normas , Implante de Prótese Vascular/normas , Prótese Vascular/normas , Vasos Coronários/cirurgia , Desenho de Prótese/normas , Stents/normas , Estenose da Valva Aórtica , Ensaios Clínicos como Assunto , Consenso , Humanos
12.
Circ J ; 82(8): 2041-2048, 2018 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-29794401

RESUMO

BACKGROUND: This study compared the long-term outcomes of prosthetic heart valve replacement with mechanical or bioprosthetic valves in patients with prior stroke.Methods and Results:In total, 1,984 patients with previous stroke who had received valve replacement between 2000 and 2011 were identified using the Taiwan National Health Insurance Research Database. Propensity score matching analysis was used. Ultimately, 547 patients were extracted from each group and were eligible for analysis. On survival analysis, the risks of all-cause mortality and recurrence of stroke were similar. The incidence of major bleeding was greater in the mechanical valve group than in the bioprosthetic valve group (P=0.040), whereas no difference was observed in re-do valve surgery. On subgroup analysis, the bioprosthetic valve was favored for older age (≥60 years) and previous gastrointestinal (GI) bleeding patients. The mechanical valve, however, was favored for younger patients (<60 years). CONCLUSIONS: In patients with previous stroke, bioprosthetic valves had a lower incidence of complications connected to major bleeding than did the mechanical valves. Survival and stroke recurrence rates, however, did not differ between the 2 groups. We recommend bioprosthetic valves for patients >60 years or who have a history of GI bleeding.


Assuntos
Bioprótese/normas , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas/normas , Acidente Vascular Cerebral/terapia , Idoso , Bioprótese/efeitos adversos , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Recidiva , Estresse Mecânico , Análise de Sobrevida
13.
Rev. bras. cir. cardiovasc ; 33(2): 122-128, Mar.-Apr. 2018. tab
Artigo em Inglês | LILACS | ID: biblio-958395

RESUMO

Abstract Objective: The aim of this retrospective study was to compare early postoperative outcomes after aortic valve replacement (AVR) with sutureless bioprostheses and conventional stented bioprostheses implanted through median sternotomy. Methods: From January 2011 to December 2016, 763 patients underwent aortic valve replacement with bioprostheses; of these, 139 received a Perceval S sutureless valve (Group A) and 624 received a Perimount Magna Ease valve (Group B). These groups were further divided into A1 (isolated Perceval AVR), A2 (Perceval AVR with coronary artery bypass grafting [CABG]), B1 (isolated conventional stented bioprosthesis), and B2 (conventional stented bioprosthesis + CABG). Results: Patients in Group A were older (mean 74 years vs. 71 years; P<0.0001), predominantly women (53% vs. 32%; P<0.0001), had a higher logistic EuroSCORE (3.26 vs. 2.43; P<0.001), more preoperative atrial fibrillation (20% vs. 13%; P=0.03), and had a lower reopening rate for bleeding (2.1% vs. 6.7%; P=0.04). Compared to Group B1, Group A1 had shorter cross-clamp (mean 40 min vs. 57 min; P≤0.0001) and bypass times (mean 63 min vs. mean 80 min; P=0.02), and they bled less postoperatively (mean 295 ml vs. mean 393 ml; P=0.002). The mean gradient across Perceval valve was 12.5 mmHg while its effective orifice area was 1.5 cm2. Conclusion: In our retrospective study of 763 patients, sutureless valve group patients are older, mostly women, more symptomatic preoperatively, and have higher logistic EuroSCORE. They have shorter cross-clamp and bypass times, less postoperative bleeding, and reduced incidence of reopening. Further studies are needed to evaluate the clinical benefits in short, mid, and long-terms.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/cirurgia , Período Pós-Operatório , Desenho de Prótese , Fatores de Tempo , Ponte Cardiopulmonar/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Constrição , Esternotomia/métodos , Procedimentos Cirúrgicos sem Sutura/métodos
14.
Biomed Res Int ; 2018: 5429594, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29546062

RESUMO

The aim of the present in vitro study was the evaluation of the fluid dynamical performance of the Carpentier-Edwards PERIMOUNT Magna Ease depending on the prosthetic size (21, 23, and 25 mm) and the cardiac output (3.6-6.4 L/min). A self-constructed flow channel in combination with particle image velocimetry (PIV) enabled precise results with high reproducibility, focus on maximal and local peek velocities, strain, and velocity gradients. These flow parameters allow insights into the generation of forces that act on blood cells and the aortic wall. The results showed that the 21 and 23 mm valves have a quite similar performance. Maximal velocities were 3.03 ± 0.1 and 2.87 ± 0.13 m/s; maximal strain Exx , 913.81 ± 173.25 and 896.15 ± 88.16 1/s; maximal velocity gradient Eyx , 1203.14 ± 221.84 1/s and 1200.81 ± 61.83 1/s. The 25 mm size revealed significantly lower values: maximal velocity, 2.47 ± 0.15 m/s; maximal strain Exx , 592.98 ± 155.80 1/s; maximal velocity gradient Eyx , 823.71 ± 38.64 1/s. In summary, the 25 mm Magna Ease was able to create a wider, more homogenous flow with lower peak velocities especially for higher flow rates. Despite the wider flow, the velocity values close to the aortic walls did not exceed the level of the smaller valves.


Assuntos
Valva Aórtica/fisiopatologia , Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Hidrodinâmica , Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Implantação de Prótese , Reologia/métodos
15.
Circ J ; 81(4): 468-475, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28132979

RESUMO

BACKGROUND: Prosthesis-patient mismatch (PPM) is associated with increased mid-term and long-term mortality rates after aortic valve replacement (AVR). This study aimed to evaluate the efficacy of the Carpentier-Edwards Perimount Magna and Magna Ease (CEPMs) aortic bioprostheses to reduce the incidence of PPM.Methods and Results:Altogether, 282 consecutive patients (113 women, mean age 69.9±9.9 years) underwent AVR with a CEPMs between 2008 and 2015. They were divided into 3 groups based on the risk of PPM as a result of their body surface area and aortic annular diameter (BSA/AnnD ratio): low-risk (LR) group: 0.64±0.05 m2/cm (n=94); medium-risk (MR) group: 0.73±0.02 m2/cm (n=94); high-risk (HR) group: 0.83±0.05 m2/cm (n=94). The 30-day mortality rate was 0.4%. The 5-year actuarial survival rates were 93.2%, 92.3%, and 94.8% for groups LR, MR, and HR, respectively. No explants as a result of structural valve deterioration occurred. No patients showed severe PPM, defined as a measured effective orifice area index (EOAI) <0.65 cm2/m2. Although there were significant (P<0.05) differences in EOAI (0.98±0.2, 0.90±0.21, and 0.88±0.1 cm2/m2among the LR, MR, and HR groups, respectively), the corresponding transvalvular mean pressure gradients (13.0±5.5, 12.3±4.0, 12.7±5.3 mmHg) and regression rates of the left ventricular mass (29.8%, 28.7%, 28.9%) were similar among groups. CONCLUSIONS: CEPMs provide low surgical risk and reduce the risks of PPM, even in HR patients, with excellent hemodynamics.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/normas , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Taxa de Sobrevida
16.
Int J Mol Sci ; 17(9)2016 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-27589735

RESUMO

Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification.


Assuntos
Bioprótese/normas , Calcinose/genética , Próteses Valvulares Cardíacas/normas , Polimorfismo Genético , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Receptores de Interleucina-6/genética , Receptor 6 Toll-Like/genética
18.
Rev. bras. cir. plást ; 31(3): 417-423, 2016. ilus, tab
Artigo em Inglês, Português | LILACS | ID: biblio-2314

RESUMO

No Brasil, 1 milhão de acidentes com queimaduras acontecem por ano e as infecções são responsáveis por 75% dos óbitos nestes pacientes, além de deixar lesões que ocasionam deformidades nas áreas atingidas. Sendo assim, o objetivo deste trabalho é fornecer uma visão atual sobre células-tronco mesenquimais (MSCs), com ênfase nas células-tronco derivadas do tecido adiposo (ADSCs), associadas a gel de plasma, gel de fibrina e membranas (scaffold). O uso de géis e membranas tendem a auxiliar o crescimento celular visando sua possível aplicação na Cirurgia Plástica Reparadora para o tratamento pacientes queimados ou que necessitam de enxerto de pele. O presente trabalho abordou de forma exploratória e narrativa o tema células-tronco mesenquimais, células-tronco mesenquimais derivadas do tecido adiposo, gel de fibrina, gel de plasma e scaffold. O tipo de pesquisa empregada foi conduzido com coleta de informações utilizando-se a Biblioteca Virtual em Saúde (BVS) e PubMed. O número absoluto de artigos publicados relacionados ao tratamento de queimaduras é considerável. Até o momento, a quantidade de pesquisas relacionadas à terapia com células-tronco derivadas do tecido adiposo, gel de fibrina, gel de plasma e scaffold para o tratamento de queimaduras apresenta-se escassa. O autoenxerto de ADSCs associado a biocurativos torna-se uma perspectiva promissora na Cirurgia Plástica Reparadora para o tratamento e recuperação de pacientes que sofreram queimaduras ou outros acidentes que necessitam de enxerto de pele. Estes recursos podem reduzir a dor e prover a dessecação da lesão, promovendo neovascularização e a reepitelização da ferida.


In Brazil, 1 million burn accidents occur annually, and subsequent wound infections account for 75% cases of deaths among these patients, in addition to inducing deformities in the affected areas. Therefore, the aim of this study was to discuss the current status of mesenchymal stem cells, with an emphasis on adipose-derived stem cells (ADSCs), in combination with plasma gel, glue fibrin, and membranes (scaffold). The use of gels and membranes supports cell growth, and aims at potential application in reconstructive plastic surgery for the treatment of burn patients or individuals requiring skin grafts. This study explores and discusses the role of mesenchymal stem cells, adipose-derived mesenchymal stem cells, glue fibrin, plasma gel, and the scaffold. This research collected information from the Virtual Health Library (VHL) and PubMed. A considerable number of articles have been published on burn treatment. However, there is little research on burn treatment with ADSCs, glue fibrin, plasma gel, and scaffold. An ADSC autograft combined with a biological dressing is promising in reconstructive plastic surgery for the treatment and recovery of burn patients or individuals with other injuries that require skin grafts. These features can reduce pain and aid in drying of the lesion, thus promoting neovascularization and wound reepithelialization.


Assuntos
Humanos , História do Século XXI , Pele , Transplante Autólogo , Bioprótese , Queimaduras , Membrana Celular , Revisão , Procedimentos de Cirurgia Plástica , Células-Tronco Mesenquimais , Géis , Pele/lesões , Transplante Autólogo/métodos , Bioprótese/efeitos adversos , Bioprótese/normas , Queimaduras/cirurgia , Queimaduras/complicações , Membrana Celular/patologia , Membrana Celular/transplante , Tecido Adiposo , Tecido Adiposo/cirurgia , Tecido Adiposo/lesões , Procedimentos de Cirurgia Plástica/métodos , Células-Tronco Mesenquimais/patologia , Géis/efeitos adversos , Géis/uso terapêutico , Neovascularização Patológica , Neovascularização Patológica/cirurgia , Neovascularização Patológica/patologia , Neovascularização Patológica/terapia
19.
Ann Thorac Cardiovasc Surg ; 21(3): 254-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26004117

RESUMO

BACKGROUND: Based on the revised AHA/ACC guidelines, it might be necessary to take into consideration the average life expectancy of Japanese people and revise the Japanese guidelines accordingly. Accordingly, we performed the present study to compare the long-term outcome in patients aged 65 years or older who underwent prosthetic valve replacement at our hospital using mechanical valves or biological valves. METHODS: We have performed valve replacement in 416 patients aged 65 years or older (mechanical: 157; biological: 244). RESULTS: There was no significant difference between the mechanical and biological valve for the actuarial survival rate. As for the valve-related complication free rate, in the mechanical valve group, the rates were significantly higher for all patients, aortic valve replacement (AVR) patients, and mitral valve replacement (MVR) patients. CONCLUSIONS: Following revision of the AHA/ACC guidelines for selection of prosthetic valves, it is necessary to investigate whether patients aged 60-70 represent the gray zone for selecting valves as in US and European guidelines, or whether a higher age is more appropriate in view of the longer average life expectancy in Japan. Accordingly, further evaluation of the long-term outcome for mechanical and biological valves in Japanese patients is needed to obtain evidence for preparation of original Japanese guidelines on prosthetic valve selection.


Assuntos
Povo Asiático , Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valvas Cardíacas/cirurgia , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Bioprótese/normas , Feminino , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/etnologia , Doenças das Valvas Cardíacas/mortalidade , Próteses Valvulares Cardíacas/normas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/normas , Humanos , Japão/epidemiologia , Estimativa de Kaplan-Meier , Expectativa de Vida/etnologia , Masculino , Guias de Prática Clínica como Assunto/normas , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
Eur J Pharmacol ; 759: 192-9, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-25814251

RESUMO

To progress into clinical practice, a bioprosthetic heart valve must first pass through the preclinical evaluation phase. The International Standards Organization (ISO) recommends implantation of concurrent controls in any evaluation of a new or modified heart valve. A total of 8 adult sheep underwent aortic valve replacement, receiving either the CE Perimount Magna 3000 aortic pericardial bioprosthetic valve or the CE Perimount RSR aortic pericardial bioprosthetic valve, Model 2800. We performed serial blood sampling, echocardiography, angiography and necropsy after euthanasia. All 8 sheep survived until the end of their study term. Our 2-dimensional echocardiographic analysis showed a mean pressure gradient of 37.4±6.0mmHg at 14 days and 37.0±5.9mmHg at 90 days; mean cardiac output was 10.0±2.8l/min at 14 days and 9.6±1.6l/min at 90 days. Angiography before euthanasia showed a mean aortic transvalvular gradient of 32.3±15.3mmHg. At euthanasia, we saw no evidence of calcification in any of the valves. In our study, we found that both models of the CE bioprosthetic heart valve we tested proved to be valid controls, in the aortic position, in sheep-with no evidence of calcification. Most important, the valves we tested had a few model-related problems, allowing a clear determination of their suitability for introduction into a clinical trial. Investigators now have additional insight into the safety of these 2 models of valves and perhaps will be able to reduce the number of controls implanted.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Aprovação de Equipamentos , Próteses Valvulares Cardíacas , Modelos Animais , Pericárdio/cirurgia , Animais , Bioprótese/normas , Angiografia Coronária , Eletrocardiografia , Feminino , Próteses Valvulares Cardíacas/normas , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Masculino , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA