Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.630
Filtrar
1.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730400

RESUMO

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Assuntos
Resinas Compostas , Infiltração Dentária , Resistência à Flexão , Dureza , Teste de Materiais , Propriedades de Superfície , Técnicas In Vitro , Humanos , Análise do Estresse Dentário , Materiais Dentários/química , Estresse Mecânico , Polietilenoglicóis , Ácidos Polimetacrílicos/química , Bis-Fenol A-Glicidil Metacrilato
2.
BMC Oral Health ; 24(1): 562, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38745306

RESUMO

BACKGROUND: Dentin hypersensitivity (DH) is one of the most challenging and persistent dental complaints characterized by transient, intense pain triggered by various stimuli. It affects a significant portion of the global population, predominantly those aged 20-40. This study aims to evaluate the desensitizing efficacy of seventh-generation dentin bonding agents (Single Bond Universal by 3 M ESPE and Xeno-V + by Dentsply) against a control group using Bifluorid 12 by Voco in mitigating DH within a month of the follow-up period. METHODS: This was a single-center, parallel-group, double-blind, controlled randomized clinical trial conducted at Dow University of Health Sciences, Karachi, Pakistan. A total of 105 patients with DH were allocated into three groups for this study. The patients were divided into three groups (Single Bond Universal by 3 M ESPE and Xeno-V + by Dentsply) and the control group containing fluoride varnish (Bifluorid 12 by Voco). Discomfort Interval Scale scores and Schiff Cold Air Sensitivity Scale scores were recorded at baseline, immediately after the intervention, after 01 weeks, and after 01 month. RESULTS: All the materials demonstrated a statistically significant reduction in discomfort and sensitivity (DIS scores p-value 0.01) immediately after 01 week and over a period of 01 month after treatment compared with the baseline scores before application, with no single material proving superior over the one-month observation period. The study also provided insights into dental hygiene practices, with a significant majority using a toothbrush and sensitivity patterns, with cold stimuli being the most common cause of sensitivity. CONCLUSION: The study demonstrates that Single Bond Universal, Xeno V+, and Bifluorid 12 are equally effective in reducing dentin hypersensitivity, with no distinct superiority observed over a one-month period. The findings highlight the potential of fluoride varnishes as a less technique-sensitive and cost-effective option for treating DH, offering valuable insights for future research and clinical practice. TRIAL REGISTRATION: NCT04225247 ( https://clinicaltrials.gov/study/NCT04225247 ), Date of Registration: 13/01/2020. (Retrospectively registered).


Assuntos
Dessensibilizantes Dentinários , Sensibilidade da Dentina , Adesivos Dentinários , Fluoretos Tópicos , Humanos , Sensibilidade da Dentina/tratamento farmacológico , Feminino , Método Duplo-Cego , Masculino , Adulto , Dessensibilizantes Dentinários/uso terapêutico , Adesivos Dentinários/uso terapêutico , Fluoretos Tópicos/uso terapêutico , Fluoretos/uso terapêutico , Adulto Jovem , Bis-Fenol A-Glicidil Metacrilato/uso terapêutico , Resultado do Tratamento , Cimentos de Resina/uso terapêutico , Medição da Dor
3.
Braz Dent J ; 35: e245720, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38775593

RESUMO

This study evaluated a new method of adhesive system application on the bond strength between fiber post and root dentin using two adhesive systems. The canals of sixty bovine incisors were prepared and obturated. The roots were divided into six groups (n=10) according to the adhesive system (Clearfil SE - CSE and Single Bond Universal - SBU) and the application strategy (microbrush - MB; rotary brush - RB; and ultrasonic tip - US). The glass fiber posts were cemented with resin cement (RelyX ARC). The roots were sectioned perpendicularly to their long axis, and three slices per root were obtained. Previously to the push-out test, confocal laser scanning microscopy (CLSM) was performed to illustrate the interfacial adaptation of the cement to the root canal walls. Failure patterns were analyzed with 40x magnification. Shapiro-Wilk indicated a normal distribution of the data. The bond strength values were compared using one-way ANOVA and Tukey's tests. Student's T test analyzed the differences between the adhesive systems within each third and protocol. A significance level of 5% was used. CSE with RB showed higher mean bond strength values compared to MB (conventional technique) (P < 0.05). US application resulted in intermediate bond strength values for CSE (P > 0.05). The application of SBU using RB generated higher mean bond strength values compared to MB and US (P < 0.05). Adhesive failures were predominant (65.5%). CSE and SBU application with the new rotary brush improved the bond strength of fiber posts to root dentin compared to the conventional strategy.


Assuntos
Dentina , Técnica para Retentor Intrarradicular , Cimentos de Resina , Bovinos , Animais , Cimentos de Resina/química , Colagem Dentária/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Adesivos Dentinários/química , Microscopia Confocal , Ácidos Polimetacrílicos/química , Teste de Materiais , Vidro/química , Raiz Dentária , Polietilenoglicóis/química , Análise do Estresse Dentário
4.
J Contemp Dent Pract ; 25(3): 245-249, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690698

RESUMO

AIM: The aim of the study is to determine the difference in the shear bond strengths to dentin among dental composite (Filtek Z350®, 3M), compomer (Dyract Flow®, Dentsply) and Giomer (Beautifil®, Shofu) with 3MTM Single BondTM Universal Adhesive (SBU) (7th generation, self-etch, single solution adhesive) and AdperTM Single Bond 2 Adhesive (ASB) (5th generation, total-etch, two solution adhesive). MATERIALS AND METHODS: Sixty extracted human permanent teeth were collected, cleansed of debris, and placed in distilled water. The samples were segregated into two groups depicting the two bonding agents-AdperTM (ASB) and 3MTM Single Bond Universal (SBU) and sub-grouped into three groups depicting the three restorative materials (Composite, Giomer, and Compomer) used. Groups were respresented as follows: Group I-ASB + Composite; Group II-ASB + Giomer; Group III-ASB + Compomer; Group IV-SBU + Giomer; Group V-SBU + Compomer; Group VI-SBU + Composite. After applying the bonding agent as per the manufacturer's instructions, following which the restorative material was placed. A Universal Testing Machine (Instron 3366, UK) was employed to estimate the shear bond strength of the individual restorative material and shear bond strengths were calculated. RESULTS: Composite bonded with SBU (group VI) displayed the greatest shear strength (11.16 ± 4.22 MPa). Moreover, Giomers and flowable compomers displayed better bond strengths with ASB compared with their SBU-bonded counterparts. CONCLUSION: These results mark the importance of careful material selection in clinical practice and the bonding agent used to achieve optimal bond strength and enhance the clinical longevity and durability of dental restorations. CLINICAL SIGNIFICANCE: From a clinical perspective, to avoid a compressive or a shear failure, it would be preferrable to use a direct composite restorative material with SBU (Single bond universal adhesive, 7th generation) to achieve maximum bond strength. How to cite this article: Kuchibhotla N, Sathyamoorthy H, Balakrishnan S, et al. Effect of Bonding Agents on the Shear Bond Strength of Tooth-colored Restorative Materials to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):245-249.


Assuntos
Compômeros , Resinas Compostas , Colagem Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Dentina , Resistência ao Cisalhamento , Resinas Compostas/química , Humanos , Colagem Dentária/métodos , Adesivos Dentinários/química , Técnicas In Vitro , Compômeros/química , Bis-Fenol A-Glicidil Metacrilato , Restauração Dentária Permanente/métodos , Teste de Materiais , Cimentos de Ionômeros de Vidro/química , Materiais Dentários/química , Resinas Acrílicas/química
5.
Clin Oral Investig ; 28(5): 271, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38658431

RESUMO

OBJECTIVES: This in vitro study evaluated the effect of different colouring solutions and primer systems used in the bonding of brackets on enamel colour change and bond strength. MATERIALS AND METHODS: 120 premolar teeth were divided into four main groups; brackets were bonded with 37% orthophosphoric acid + Transbond XT Primer in Group 1, 3 M Single Bond Universal in Group 2, Transbond Plus SEP in Group 3, and G-Premio Bond in Group 4. Each group was divided into three subgroups, and the teeth were placed in a cup containing coffee and tea mixture, in a cup containing cola and in distilled water. A bond strength test was applied to all teeth. Colour measurements of all teeth were performed at 2 different times: before bonding and after the bond strength test. RESULTS: The average bond strength of the 37% orthophosphoric acid group was higher than that of the other groups. The effect of primer and solution groups on colour change was statistically significant (p = 0.001 and p = 0.023, respectively). CONCLUSIONS: In this study, the bond strength was clinically sufficient in all primer groups. The highest colour change was observed when the tea-coffee solution and Transbond Plus SEP primer were used. CLINICAL RELEVANCE: This study has identified enamel discoloration and bond strength from different colouring solutions and primer systems used for bonding braces, which can be used to inform clinicians and patients to achieve better treatment results.


Assuntos
Dente Pré-Molar , Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Braquetes Ortodônticos , Cimentos de Resina , Resistência ao Cisalhamento , Humanos , Colagem Dentária/métodos , Técnicas In Vitro , Cimentos de Resina/química , Cor , Corantes , Teste de Materiais , Esmalte Dentário/química , Análise do Estresse Dentário , Ácidos Fosfóricos/química , Propriedades de Superfície , Chá/química , Condicionamento Ácido do Dente
6.
Dent Mater ; 40(5): 837-841, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570242

RESUMO

OBJECTIVES: to assess the impact of universal adhesives, cured with single-peak and polywave LEDs, on the metabolic activity and cytokine release of human dental pulp stem cells (hDPSCs). In addition, analyze the degree of conversion (DC) of the adhesives cured with the different LEDs. METHODS: Discs (5 mm diameter, 1 mm thick) were prepared using three universal adhesives: Single Bond Universal (SBU, 3 M ESPE), Optibond Universal (OBU, Kerr), and Zipbond Universal (ZBU, SDI). These discs were cured for 40 s using a single-peak (DeepCure, 3 M ESPE) or a polywave light-emmiting diode (LED) curing unit (Valo Grand, Ultradent). After 24 h, the specimens were placed in 24-well culture plates, each containing 1 mL of culture medium for 24 h. hDPSCs (1.8 ×104) were seeded in 96-well plates and allowed to grow for 24 h. Subsequently, the cells were exposed to the extracts (culture medium containing eluates from the adhesive discs) for an additional 24 h. Cells not exposed to the extracts were used as a control group. The mitochondrial metabolism was assessed using the MTT assay and the cytokine release evaluated through MAGPIX. The degree of conversion of the adhesives was analyzed using FTIR (n = 5). The results were analyzed by ANOVA two-way and Tukey's test. RESULTS: OBU and ZBU eluates caused a statistically significant reduction in mitochondrial metabolism, regardless of the LED used, indicating their cytotoxicity. In contrast, SBU did not significantly affect the MTT results, resembling the control group. A higher release of cytokines IL-1, IL-6, IL-10, and TNF-α were found in association to ZBU. SBU, on the other hand, increased the release of IL-8. OBU did not influenced the cytokine release. SBU presented the higher DC, while OBU and ZBU had similar DC, lower than SBU. SIGNIFICANCE: In conclusion, universal adhesives exhibit toxicity towards hDPSCs, but the extent of toxicity varies depending on the adhesive material. ZBU was associated with increased cytokine release, particularly pro-inflammatory mediators, from hDPSCs. The different LEDs did not influenced the cytotoxicity of the evaluated adhesives.


Assuntos
Lâmpadas de Polimerização Dentária , Citocinas , Cimentos Dentários , Polpa Dentária , Teste de Materiais , Células-Tronco , Humanos , Polpa Dentária/citologia , Citocinas/metabolismo , Cimentos Dentários/química , Cimentos Dentários/farmacologia , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/química , Cimentos de Resina/toxicidade , Células Cultivadas , Bis-Fenol A-Glicidil Metacrilato/toxicidade , Bis-Fenol A-Glicidil Metacrilato/química
7.
Anal Chim Acta ; 1303: 342511, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38609261

RESUMO

BACKGROUND: Mammalian cells both import exogenous fatty acids and synthesize them de novo. Palmitate, the end product of fatty acid synthase (FASN) is a substrate for stearoyl-CoA desaturases (Δ-9 desaturases) that introduce a single double bond into fatty acyl-CoA substrates such as palmitoyl-CoA and stearoyl-CoA. This process is particularly upregulated in lipogenic tissues and cancer cells. Tracer methodology is needed to determine uptake versus de novo synthesis of lipids and subsequent chain elongation and desaturation. Here we describe an NMR method to determine the uptake of 13C-palmitate from the medium into HCT116 human colorectal cancer cells, and the subsequent desaturation and incorporation into complex lipids. RESULTS: Exogenous 13C16-palmitate was absorbed from the medium by HCT116 cells and incorporated primarily into complex glycerol lipids. Desaturase activity was determined from the quantification of double bonds in acyl chains, which was greatly reduced by ablation of the major desaturase SCD1. SIGNIFICANCE: The NMR approach requires minimal sample preparation, is non-destructive, and provides direct information about the level of saturation and incorporation of fatty acids into complex lipids.


Assuntos
Bis-Fenol A-Glicidil Metacrilato , Ácidos Graxos , Imageamento por Ressonância Magnética , Humanos , Animais , Isótopos , Palmitatos , Ácidos Graxos Dessaturases , Mamíferos
8.
J Dent Res ; 103(5): 536-545, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38549255

RESUMO

Dimethacrylate-based chemistries feature extensively as resin monomers in dental resin-based materials due to their distinguished overall performance. However, challenges endure, encompassing inadequate mechanical attributes, volumetric shrinkage, and estrogenicity. Herein, we first synthesized a novel resin monomer, 9-armed starburst polyurethane acrylate (NPUA), via the grafting-onto approach. Compared to the primary commercial dental monomer 2,2-bis [p-(2'-hydroxy-3'-methacryloxypropoxy) phenyl] propane (Bis-GMA) (with a viscosity of 1,174 ± 3 Pa·s and volumetric shrinkage of 4.7% ± 0.1%), the NPUA monomer achieves the lower viscosity (158 ± 1 Pa·s), volumetric shrinkage (2.5% ± 0.1%), and cytotoxicity (P < 0.05). The NPUA-based resins exhibit the higher flexural strength, flexural modulus, hardness, and hydrophobicity and lower volumetric shrinkage, water absorption, and solubility compared to the Bis-GMA (70 wt%)/TEGDMA (30 wt%) resins. The NPUA-based composites exhibit significantly higher flexural strength, flexural modulus, and hardness and lower volumetric shrinkage (171.4 ± 3.0 MPa, 12.6 ± 0.5 GPa, 2.0 ± 0.2 GPa, and 3.4% ± 0.2%, respectively) compared to the Bis-GMA group (120.3 ± 4.7 MPa, 9.4 ± 0.7 GPa, 1.5 ± 0.1 GPa, and 4.7% ± 0.2%, respectively; P < 0.05). This work presents a viable avenue for augmenting the physicochemical attributes of dental resins.


Assuntos
Resinas Acrílicas , Teste de Materiais , Metacrilatos , Poliuretanos , Poliuretanos/química , Viscosidade , Metacrilatos/química , Resinas Compostas/química , Resistência à Flexão , Materiais Dentários/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimerização , Ácidos Polimetacrílicos/química , Dureza , Propriedades de Superfície
9.
Dent Mater ; 40(4): 608-618, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38369405

RESUMO

OBJECTIVE: The current dental resin composites often suffer from polymerization shrinkage, which can lead to microleakage and potentially result in recurring tooth decay. This study presents the synthesis of a novel monomer, (3,9-diethyl-1,5,7,11-tetraoxaspiro[5,5]undecane-3,9-diyl)bis(methylene) bis((2-(3-(prop-1-en-2-yl)phenyl)propan-2-yl)carbamate) (DDTU-IDI), and evaluates its effect in the formulation of low-shrinkage dental resin composites. METHODS: DDTU-IDI was synthesized through a two-step reaction route, with the initial synthesis of the required raw material monomer 3,9-diethyl-3,9-dihydroxymethyl-1,5,7,11-tetraoxaspiro-[5,5] undecane (DDTU). The structures were confirmed using Fourier-transform infrared (FT-IR) spectroscopy and hydrogen nuclear magnetic resonance (1HNMR) spectroscopy. Subsequently, DDTU-IDI was incorporated into Bis-GMA-based composites at varying weight percentages (5, 10, 15, and 20 wt%). The polymerization reaction, degree of conversion, polymerization shrinkage, mechanical properties, physicochemical properties and biocompatibility of the low-shrinkage composites were thoroughly evaluated. Furthermore, the mechanical properties were assessed after a thermal cycling test with 10,000 cycles to determine the stability. RESULTS: The addition of DDTU-IDI at 10, 15, and 20 wt% significantly reduced the polymerization volumetric shrinkage of the experimental resin composites, without compromising the degree of conversion, mechanical and physicochemical properties. Remarkably, at a monomer content of 20 wt%, the polymerization shrinkage was reduced to 1.83 ± 0.53%. Composites containing 10, 15, and 20 wt% DDTU-IDI exhibited lower water sorption and higher contact angle. Following thermal cycling, the composites exhibited no significant decrease in mechanical properties, except for the flexural properties. SIGNIFICANCE: DDTU-IDI has favorable potential as a component which could produce volume expansion and increase rigidity in the development of low-shrinkage dental resin composites. The development of low-shrinkage composites containing DDTU-IDI appears to be a promising strategy for reducing polymerization shrinkage, thereby potentially enhancing the longevity of dental restorations.


Assuntos
Alcanos , Metacrilatos , Ácidos Polimetacrílicos , Metacrilatos/química , Ácidos Polimetacrílicos/química , Espectroscopia de Infravermelho com Transformada de Fourier , Polietilenoglicóis/química , Teste de Materiais , Resinas Compostas/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimerização
10.
J Adhes Dent ; 26(1): 53-64, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38329120

RESUMO

PURPOSE: This study investigated and compared the bond strengths, microleakage, microgaps, and marginal adaptation of self-adhesive resin composites (SAC) to dentin with or without universal adhesives. MATERIALS AND METHODS: Dentin surfaces of 75 molars were prepared for shear and microtensile bond strength testing (SBS and µTBS). Silicon molds were used to build up direct restorations using the following materials to form 5 groups: 1. Surefil One; 2. Prime&Bond active Universal Adhesive + Surefil One; 3. Vertise Flow; 4. OptiBond Universal + Vertise Flow; 5. Scotchbond Universal + Filtek Z500 (control group). Bonded specimens were thermocycled 10,000x before being tested either for SBS or µTBS using a universal testing machine at a crosshead speed of 0.5 mm/min. Direct mesial and distal class-II cavities were created on 100 sound premolars, with the gingival margin of distal cavities placed below CEJ and restored according to the five groups. After thermocycling, microleakage scores were assessed following immersion of restored premolars in 2% methylene blue dye for 24 h, while marginal gaps and adaptation percentages were investigated on epoxy resin replicas under SEM at magnifications of 2000X and 200X, respectively. Results were statistically analyzed with parametric and non-parametric tests as applicable, with a level of significance set at α = 0.05. RESULTS: Bond strengths, microleakage scores, microgaps, and percent marginal adaptation of Surefil One and Vertise Flow were significantly (p < 0.001) inferior to the control group. Dentin preconditioning with universal adhesives significantly increased the study parameter outcomes of Surefil One and Vertise Flow, yet they were still significantly below the performance of the control group. CONCLUSION: Conventional resin composite outperformed the SAC whether applied solely or in conjunction with their corresponding universal adhesives.


Assuntos
Colagem Dentária , Cimentos de Resina , Bis-Fenol A-Glicidil Metacrilato/química , Cimentos de Resina/química , Adesivos Dentinários/química , Restauração Dentária Permanente/métodos , Cimentos Dentários , Dentina , Resinas Compostas/química , Teste de Materiais
11.
BMC Oral Health ; 24(1): 244, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38360710

RESUMO

Today, resin materials are used in the restoration of permanent and deciduous teeth or as fissure sealants. The materials can contain different types of monomers (Bis-GMA, UDMA, TEGDMA). These monomers can be released into the oral cavity after polymerization. Residual monomers released from resin-containing restorative materials after polymerization have been reported to have negative effects on mechanical properties. The aim of our study is to evaluate the amount of residual monomers released after polymerization of different flowable composite resin materials using two different modes of LED light source. Composite disc samples (8 mm diameter/2 mm depth) prepared for each material group were polymerized using two different modes of the LED light device (Standard mode and extra power mode). HPLC (High Performance Liquid Chromatography) device was used to measure the amount of residual monomer release at 1 h, 1 day, 3 days and 7 days periods. Pairwise comparison of the differences between the materials was performed by Post-hoc test. For each residual monomer, the Kruskal Wallis test was used to analyze the difference between the materials in standard mode and the difference between the materials in extra power mode. According to the results of the study; Grandio flow flowable composite showed the highest release of TEGDMA and Bis-GMA while SDR® Flow flowable composite showed the lowest release of TEGDMA, Bis-GMA and UDMA. For all materials, the extra power mode resulted in more residual monomer release. TEGDMA and Bis-GMA release was detected in all tested flowable composites at all time periods.


Assuntos
Resinas Compostas , Polietilenoglicóis , Ácidos Polimetacrílicos , Humanos , Bis-Fenol A-Glicidil Metacrilato/química , Teste de Materiais , Resinas Compostas/química , Ácidos Polimetacrílicos/química , Selantes de Fossas e Fissuras , Metacrilatos
12.
Niger J Clin Pract ; 27(1): 1-7, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38317028

RESUMO

BACKGROUND: Compomers are restorative materials commonly used in pediatric dentistry. It is important to investigate the monomer release of materials used especially in pediatric patients. The aim of this study was to evaluate the residual monomer released from different-colored flowable compomers at five polymerization times. MATERIALS AND METHODS: Three experimental groups were formed: Group 1: pink flowable compomer (Twinky Star, VOCO, Germany), Group 2: blue flowable compomer (Twinky Star, VOCO), Group 3: white flowable compomer, A2 color of Dyract XP (Dentslpy DeTrey, Konstanz, Germany). For each group, samples were prepared using standard cylindrical Teflon molds (n = 10), and the compomers were cured using a light-emitting diode (LED) source in accordance with the manufacturer's recommendations. During each time period, the number of residual monomers: bisphenol-A glycidyl methacrylate (bis-GMA), urethane dimethacrylate (UDMA), hydroxyethyl methacrylate (HEMA), and triethylene glycol dimethacrylate (TEGDMA) were determined with high-performance liquid chromatography (HPLC). All data were analyzed statistically. RESULTS: In all groups, the amount of residual monomers increased after 1-h release periods (P < 0.05). For 2 weeks, the total residual monomers released were determined at most in Group 3 and at least in Group 1. However, there was no significant difference between the groups in terms of released amounts of monomers (P > 0.05). CONCLUSIONS: According to the study, when the total amount of residual monomer released from all groups was compared, no difference was found and it was observed that none of them exceeded the toxic dose. Flowable colored compomers can be used as safely as white compomers in pediatric dentistry.


Assuntos
Compômeros , Resinas Compostas , Humanos , Criança , Compômeros/química , Polimerização , Bis-Fenol A-Glicidil Metacrilato/química , Cromatografia Líquida de Alta Pressão , Teste de Materiais , Resinas Compostas/química
13.
J Dent ; 143: 104897, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38395377

RESUMO

OBJECTIVES: This study aimed to evaluate the adhesive properties in dentine after the application of silver diamine fluoride (SDF) on carious dentine lesions immediately and after 2 years of water storage. METHODS: 96 human molars used were subjected to artificial dentine caries production, and then randomly divided into 12 experimental groups according to 1. application of an SDF solution (carious dentine lesion without SDF treatment [control], with 12 % silver diamine fluoride [SDF 12 %] or 38 % silver diamine fluoride [SDF 38 %]); 2. Universal adhesives (Clearfil Universal Bond Quick [CUQ] and Single Bond Universal [SBU]); 3. adhesive strategy (etch-and-rinse [ER] and self-etch [SE]). After restoration, the specimens were sectioned and submitted to the microtensile bond strength test (µTBS) and energy-dispersive X-ray spectrometry analysis (SEM/EDX). All tests were performed immediately and after 2 years of water storage. Data from the µTBS were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the interaction of factors 'SDF' vs 'time' was significant (p = 0.03). After 2 years of storage, the groups where SDF was applied showed higher µTBS values compared to the control group. No significant decrease in µTBS values was observed for SBU when comparing immediate and 2-year results, but a significant reduction in µTBS values was observed after 2 years for CUQ. CONCLUSION: Independent of the adhesive strategy, the use of SDF may be a promising alternative to maintain the bonding of universal adhesives to carious dentinal lesions. CLINICAL SIGNIFICANCE: This study may clarify and support clinicians regarding the longevity of resin-based restoration in caries-affected dentine treated with silver diamine fluoride.


Assuntos
Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Cárie Dentária , Compostos de Amônio Quaternário , Compostos de Prata , Humanos , Cimentos Dentários , Suscetibilidade à Cárie Dentária , Dentina , Água/química , Teste de Materiais , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Fluoretos Tópicos
14.
Dent Mater J ; 43(2): 137-145, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38233189

RESUMO

This study aimed to evaluate the shear bond strength of two flowable composite resins to resin-matrix ceramic CAD-CAM materials.Fifty-four plates obtained from Lava Ultimate (LU), Cerasmart (CS), and Vita Enamic (VE) CAD-CAM blocks were assigned to nine groups: N0: Nova Compo SF (NCSF), N1: Silane/Single Bond Universal (SBU)/NCSF, N2: SBU/NCSF, N3: Silane/G-Premio Bond (GPB)/NCSF, N4: GPB/NCSF, G1: Silane/SBU/G-aenial Universal Injectable Composite (GUIC), G2: SBU/GUIC, G3: Silane/GPB/GUIC, G4: GPB/GUIC. After the repair procedures, shear bond strength values were analyzed. Silane pre-application decreased bond strength in most LU and CS groups but increased it in VE. NCSF performed better than GUIC in all CAD-CAM's with similar adhesive protocols. SBU in combination with NSCF had the highest bond strength among all repair procedures in LU and CS. Silane-containing universal adhesives in combination with self-adhesive resin composites should be used to repair resin-matrix ceramic materials.


Assuntos
Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Metacrilatos , Cimentos de Resina , Cimentos de Resina/química , Cimentos Dentários , Silanos/química , Propriedades de Superfície , Resinas Compostas/química , Cerâmica/química , Desenho Assistido por Computador , Teste de Materiais
15.
Braz Oral Res ; 38: e001, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38198301

RESUMO

The aim of this study was to evaluate the influence of adding quaternary ammonium methacrylates (QAMs) to experimental adhesives by assessing the degree of conversion (DC), cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. Two QAMs were added to an experimental adhesive: dimethylaminododecyl methacrylate bromododecane (DMADDM) or dimethylaminododecyl methacrylate bromohexadecane (DMAHDM) at three concentrations each: 1, 2.5, and 5 wt.%. Experimental adhesive without QAMs (control group) and commercially available Transbond XT Primer (3M Unitek, Monrovia, California, USA) were used for comparisons. The adhesives were tested for DC, cytotoxicity against keratinocytes and fibroblasts, and antibacterial activity against biofilm formation. DC, cytotoxicity against fibroblasts, and antibacterial activity were analyzed using one-way ANOVA and Tukey's multiple comparisons. Cytotoxicity against keratinocytes was evaluated using the Kruskal Wallis and Dunn's post-hoc (α = 5%) tests. Transbond showed lower DC as compared to 5% DMAHDM, 1% DMADDM, and 5% DMADDM (p < 0.05). However, all groups presented proper DC when compared to commercial adhesives in the literature. In the evaluation of cytotoxicity against keratinocytes, Transbond induced higher viability than 2.5 wt.% groups (p < 0.05). Against fibroblasts, Transbond induced higher viability as compared to 5 wt.% groups (p < 0.05). DMAHDM at 5 wt.% reduced biofilm formation when compared to all the other groups (p < 0.05). Despite their cytotoxic effect against keratinocytes, gingival fibroblasts showed higher viability. DMAHDM at 5 wt.% decreased Streptococcus mutans viability. The incorporation of DMAHDM at 5 wt.% may be a strategy for reducing the development of white spot lesions.


Assuntos
Antibacterianos , Bis-Fenol A-Glicidil Metacrilato , Hidrocarbonetos Bromados , Metacrilatos , Metilaminas , Compostos de Amônio Quaternário , Metacrilatos/farmacologia , Antibacterianos/farmacologia
16.
Eur J Oral Sci ; 132(1): e12966, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38062539

RESUMO

The objective of this study was to determine the effects on the colour of adding increasing concentrations of graphene to orthodontic fixed retainer adhesives and to evaluate changes in optical transmission during light curing and the resultant degree of conversion. Two different types of adhesives commonly used for fixed retainers were investigated: A packable composite (Transbond) and a flowable composite (Transbond Supreme). Graphene was added to the adhesives in three different concentrations (0.01, 0.05, and 0.1 wt%). Adhesives without graphene addition were set as control groups. A Minolta colourimeter was used to measure the colour and translucency parameters. Irradiance transmitted during curing was quantified using MARC Light Collector. Fourier-transform infrared spectroscopy was used to record degree of conversion. Data were statistically analysed with the Student's t-test and one-way ANOVA with Tukey's tests (α = 0.05). The findings showed that incorporating graphene darkened the adhesive colour significantly and reduced translucency. As the graphene concentration reached 0.1 wt%, samples became opaque; yet, no adverse effect on degree of conversion was observed. The addition of graphene reduces optical transmission of lingual retainer adhesives; the effect increases with graphene concentration.


Assuntos
Bis-Fenol A-Glicidil Metacrilato , Colagem Dentária , Grafite , Cimentos Dentários , Cimentos de Resina/química , Teste de Materiais , Resinas Compostas/química , Adesivos/química
17.
Dent Mater ; 40(1): 59-65, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37903663

RESUMO

OBJECTIVE: To determine the effects of using K18-methyl methacrylate (K18-MMA) and K18-Filler on composite cure, esthetic, mechanical, polymerization shrinkage, and antimicrobial properties. METHODS: K18-MMA (0-20% w/w) was used to replace TEGDMA in a 70:30 Bis-GMA:TEGDMA composite filled to 70% w/w with barium glass or K18-Filler. Composite degree of cure (Rockwell15T hardness and near Infrared FTIR), hydrophilicity (contact angle measurements), translucency (transparency parameter measurements, TP), mechanical (3-point bend test), polymerization shrinkage (volumetric shrinkage and shrinkage stress), and antimicrobial properties (colony counting assay) against Streptococcus mutans, Streptococcus sanguinis, and Candida albicans were determined. RESULTS: All experimental groups had comparable degrees of cure (near Infrared FTIR and Rockwell15T Hardness), TP, moduli, polymerization volumetric shrinkages and shrinkage stresses to those of controls (Bonferroni corrected p > 0.0018). Only one group (15% K18-MMA+K18-Filler) had significantly different (lower) contact angles as compared to that of controls (Bonferroni corrected p < 0.0018). Most of the K18-Filler-containing composites had significantly lower ultimate transverse strengths (UTS) than controls (Bonferroni corrected p < 0.0018). Controls had significantly greater S mutans colony counts than 15% and 20% w/w K18-MMA+K18-Filler groups, and greater S sanguinis and C albicans colony counts than K18-containing groups. Of the composites with that provided significant antimicrobial properties against S. mutans, S. sanguinis, and C. albicans, only the 20% K18-MMA+K18-Filler group had significantly lower UTS than controls. SIGNIFICANCE: Composites with K18-MMA and K18-Filler with comparable physical properties to control composites and significant antimicrobial properties have been developed. K18-MMA and K18-Filler seem to be suitable for incorporation into commercial dental resins.


Assuntos
Anti-Infecciosos , Resinas Compostas , Resinas Compostas/farmacologia , Metilmetacrilato , Teste de Materiais , Ácidos Polimetacrílicos/farmacologia , Polietilenoglicóis , Bis-Fenol A-Glicidil Metacrilato , Metacrilatos/farmacologia , Anti-Infecciosos/farmacologia , Polimerização , Propriedades de Superfície
18.
J Oral Sci ; 66(1): 9-14, 2024 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-37866923

RESUMO

PURPOSE: The aim of this study was to measure residual monomer, cell adhesion, and cell viability of 3-dimensional printable permanent resin (PR), hybrid ceramic block (HCB), and indirect composite (IC) produced with additive, subtractive, and conventional techniques. METHODS: Five 8 × 8 × 2 mm3 samples of each material were prepared for each experiment. In a 24-h period, monomer release was analyzed with high-performance liquid chromatography, and cell viability and adhesion were evaluated with the water-soluble tetrazolium salt test. Data were analyzed with IBM SPSS Statistics 26.0 statistical software, and results were regarded as significant at α = 0.05. RESULTS: Monomer release (triethylene glycol dimethacrylate, urethane dimethacrylate, and Bisphenol A glycerolate dimethacrylate) was significantly higher in the IC group. Mean cell viability was significantly lower in the HCB group than in the IC group. CONCLUSION: All monomers in the tested materials were released at rates that were below clinical significance. Cell adhesion rates in the groups were similar. Cytotoxic response was classified as minor in the HCB and PR groups and non-cytotoxic in the IC group.


Assuntos
Resinas Compostas , Materiais Dentários , Resinas Compostas/química , Adesão Celular , Sobrevivência Celular , Metacrilatos/química , Ácidos Polimetacrílicos/química , Teste de Materiais , Bis-Fenol A-Glicidil Metacrilato/química
19.
Dent Mater ; 40(3): 441-450, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38129191

RESUMO

OBJECTIVE: To evaluate properties of fiber-reinforced-composites (FRC) containing Bis-EMA/UDMA monomers but identical dispersed phase (60% wt BaSi glass power +10% wt E-glass fibre). METHODS: A control (Group A), monomer mixture comprising 60% Bis-GMA, 30% TEGDMA, and 10% PMMA (typical FRC monomers) was used. The following monomer mass fractions were mixed: 50% bis-GMA plus 50% of different ratios of Bis-EMA+UDMA to produce consistent formulations (Groups B-E) of workable viscosities was also studied. Flexural strength (FS), fracture toughness (KIC), water sorption (SP), solubility (SL) and hygroscopic expansion (HE) were measured. FS and KIC specimens were stored for 1, 7 d, and 30 d in water at 37 °C. SP/SL specimens were water-immersed for 168d, weighed at intervals, then dried for 84 d at 37 °C. To analyze differences in FS, and KIC, a two-way ANOVA and Tukey post-hoc tests (α = 0.05) were conducted. For SP/SL, and HE, one-way ANOVA with subsequent Tukey post-hoc tests (α = 0.05) were utilized. RESULTS: FS and KIC for groups A, D, E decreased progressively after 1 d. Groups B and C (highest amounts of Bis-EMA) did not decrease significantly. The modified matrix composites performed significantly better than the control group for SP and HE. The control group outperformed the experimental composites only for SL with up to 250% higher SL for group E (6.9 µg/mm) but still below the maximum permissible threshold of 7.5 µg/mm. SIGNIFICANCE: EXPERIMENTAL: composites with highest amounts of Bis-EMA showed improved hydrolytic stability and overall enhancement in several clinically-relevant properties. This makes them potential candidates for alternative matrices to a semi-interpenetrating network in fiber-reinforced composites.


Assuntos
Resinas Compostas , Vidro , Poliuretanos , Bis-Fenol A-Glicidil Metacrilato , Teste de Materiais , Metacrilatos , Ácidos Polimetacrílicos , Polietilenoglicóis , Água
20.
J Mech Behav Biomed Mater ; 150: 106323, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38134585

RESUMO

OBJECTIVE: to investigate the effect of different concentrations of chitosan added to experimental resins containing either BAPO or camphorquinone (CQ) as photoinitiators, regarding degree of conversion (DC), flexural strength (FS), flexural elastic modulus (E), Knoop microhardness (KHN), cytotoxicity, genotoxicity and antimicrobial activity. METHODS: Experimental resins with polymeric matrix of BisGMA and TEGDMA was added either 0.5 wt% BAPO or 0.5 wt% camphorquinone/0.2% amine along with and chitosan concentrations of 0.5%; 1.0% or 2.0%. Degree of conversion was measured using Fourier transformed infrared spectroscopy. Flexural strength and elastic modulus were obtained through three-point bending test and Knoop microhardness was measured in a microidenter. Direct cytotoxicity was performed in human keratinocytes and genotoxicity test was done in murine macrophages cells. Antimicrobial activity was acessed against Staphylococcus aureus and Streptococcus mutans through the inhibition halo. Data were analyzed using two-way ANOVA and Tukey teste (α = 0.05). RESULTS: The materials containing photoinitiator BAPO showed higher values of DC, FS, E, and KHN compared to resins with CQ. The addition of chitosan did not affect the properties of these materials. However, in resins containing CQ, the addition of chitosan improve these properties compared to control group. For the groups containing BAPO the chitosan reduced cytotoxicity and genotoxicity compared to materials with camphorquinone. The materials with 1.0% and 2.0% chitosan showed increased antibacterial activity in the materials containing BAPO as photoinitiator for both bacteria. SIGNIFICANCE: The alternative photoinitiator BAPO and chitosan can improve physical and biological properties of photoactivated resins when compared with the materials with photoinitiator camphorquinone.


Assuntos
Anti-Infecciosos , Quitosana , Humanos , Animais , Camundongos , Resinas Compostas/química , Quitosana/farmacologia , Cânfora/farmacologia , Cânfora/química , Teste de Materiais , Metacrilatos , Polimerização , Bis-Fenol A-Glicidil Metacrilato/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA