Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.246
Filtrar
1.
Opt Lett ; 49(10): 2817-2820, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748169

RESUMO

Alteration in the elastic properties of biological tissues may indicate changes in the structure and components. Acoustic radiation force optical coherence elastography (ARF-OCE) can assess the elastic properties of the ocular tissues non-invasively. However, coupling the ultrasound beam and the optical beam remains challenging. In this Letter, we proposed an OCE method incorporating homolateral parallel ARF excitation for measuring the elasticity of the ocular tissues. An acoustic-optic coupling unit was established to reflect the ultrasound beam while transmitting the light beam. The ARF excited the ocular tissue in the direction parallel to the light beam from the same side of the light beam. We demonstrated the method on the agar phantoms, the porcine cornea, and the porcine retina. The results show that the ARF-OCE method can measure the elasticity of the cornea and the retina, resulting in higher detection sensitivity and a more extensive scanning range.


Assuntos
Córnea , Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Tomografia de Coerência Óptica , Técnicas de Imagem por Elasticidade/métodos , Animais , Suínos , Córnea/diagnóstico por imagem , Córnea/fisiologia , Tomografia de Coerência Óptica/métodos , Elasticidade , Retina/diagnóstico por imagem , Retina/fisiologia
2.
Transl Vis Sci Technol ; 13(5): 11, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38748408

RESUMO

Purpose: Computational models can help clinicians plan surgeries by accounting for factors such as mechanical imbalances or testing different surgical techniques beforehand. Different levels of modeling complexity are found in the literature, and it is still not clear what aspects should be included to obtain accurate results in finite-element (FE) corneal models. This work presents a methodology to narrow down minimal requirements of modeling features to report clinical data for a refractive intervention such as PRK. Methods: A pipeline to create FE models of a refractive surgery is presented: It tests different geometries, boundary conditions, loading, and mesh size on the optomechanical simulation output. The mechanical model for the corneal tissue accounts for the collagen fiber distribution in human corneas. Both mechanical and optical outcome are analyzed for the different models. Finally, the methodology is applied to five patient-specific models to ensure accuracy. Results: To simulate the postsurgical corneal optomechanics, our results suggest that the most precise outcome is obtained with patient-specific models with a 100 µm mesh size, sliding boundary condition at the limbus, and intraocular pressure enforced as a distributed load. Conclusions: A methodology for laser surgery simulation has been developed that is able to reproduce the optical target of the laser intervention while also analyzing the mechanical outcome. Translational Relevance: The lack of standardization in modeling refractive interventions leads to different simulation strategies, making difficult to compare them against other publications. This work establishes the standardization guidelines to be followed when performing optomechanical simulations of refractive interventions.


Assuntos
Simulação por Computador , Córnea , Análise de Elementos Finitos , Ceratectomia Fotorrefrativa , Humanos , Córnea/cirurgia , Córnea/fisiologia , Ceratectomia Fotorrefrativa/métodos , Simulação por Computador/normas , Lasers de Excimer/uso terapêutico , Modelos Biológicos
3.
Invest Ophthalmol Vis Sci ; 65(5): 34, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38776117

RESUMO

Purpose: A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods: Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results: Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions: Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.


Assuntos
Córnea , Pressão Intraocular , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Córnea/diagnóstico por imagem , Córnea/fisiologia , Pressão Intraocular/fisiologia , Fenômenos Biomecânicos/fisiologia , Idoso , Pessoa de Meia-Idade , Esclera/fisiologia , Esclera/diagnóstico por imagem , Masculino , Feminino , Glaucoma/fisiopatologia , Idoso de 80 Anos ou mais , Doadores de Tecidos , Adulto
4.
BMC Ophthalmol ; 24(1): 155, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594682

RESUMO

INTRODUCTION: In recent years, insulin eye drops have attracted increasing attention from researchers and ophthalmologists. The aim of this study was to investigate the efficacy and possible mechanism of action of insulin eye drops in diabetic mice with corneal wounds. METHODS: A type 1 diabetes model was induced, and a corneal epithelial injury model of 2.5 mm was established. We used corneal fluorescein staining, hematoxylin-eosin (H-E) staining and the Cochet-Bonnet esthesiometer to examine the process of wound healing. Subsequently, the expression levels of Ki-67, IL-1ß, ß3-tubulin and neuropeptides, including substance P (SP) and calcitonin gene-related peptide (CGRP), were examined at 72 h after corneal injury. RESULTS: Fluorescein staining demonstrated an acceleration of the recovery of corneal epithelial injury in diabetic mice compared with the saline treatment, which was further evidenced by the overexpression of Ki-67. Moreover, 72 h of insulin application attenuated the expression of inflammatory cytokines and neutrophil infiltration. Remarkably, the results demonstrated that topical insulin treatment enhanced the density of corneal epithelial nerves, as well as neuropeptide SP and CGRP release, in the healing cornea via immunofluorescence staining. CONCLUSIONS: Our results indicated that insulin eye drops may accelerate corneal wound healing and decrease inflammatory responses in diabetic mice by promoting nerve regeneration and increasing levels of neuropeptides SP and CGRP.


Assuntos
Lesões da Córnea , Diabetes Mellitus Experimental , Epitélio Corneano , Ceratite , Camundongos , Animais , Epitélio Corneano/metabolismo , Insulina , Diabetes Mellitus Experimental/complicações , Diabetes Mellitus Experimental/tratamento farmacológico , Diabetes Mellitus Experimental/metabolismo , Peptídeo Relacionado com Gene de Calcitonina/metabolismo , Soluções Oftálmicas , Antígeno Ki-67/metabolismo , Córnea/fisiologia , Lesões da Córnea/tratamento farmacológico , Cicatrização , Ceratite/metabolismo , Fluoresceína/metabolismo , Inflamação/metabolismo
5.
J Biomech ; 168: 112113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38648717

RESUMO

Atomic force microscopy (AFM) is a valuable tool for assessing mechanical properties of biological samples, but interpretations of measurements on whole tissues can be difficult due to the tissue's highly heterogeneous nature. To overcome such difficulties and obtain more robust estimates of tissue mechanical properties, we describe an AFM force mapping and data analysis pipeline to characterize the mechanical properties of cryosectioned soft tissues. We assessed this approach on mouse optic nerve head and rat trabecular meshwork, cornea, and sclera. Our data show that the use of repeated measurements, outlier exclusion, and log-normal data transformation increases confidence in AFM mechanical measurements, and we propose that this methodology can be broadly applied to measuring soft tissue properties from cryosections.


Assuntos
Microscopia de Força Atômica , Animais , Microscopia de Força Atômica/métodos , Camundongos , Ratos , Esclera/fisiologia , Esclera/diagnóstico por imagem , Córnea/fisiologia , Córnea/diagnóstico por imagem , Malha Trabecular/fisiologia , Malha Trabecular/diagnóstico por imagem , Crioultramicrotomia/métodos , Disco Óptico/diagnóstico por imagem , Disco Óptico/fisiologia , Fenômenos Biomecânicos
6.
Int Ophthalmol ; 44(1): 1, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38315313

RESUMO

PURPOSE: Idiopathic normal pressure hydrocephalus (iNPH) is associated with an increased prevalence of open-angle glaucoma, attributed to variations of the pressure gradient between intraocular and intracranial compartments at the level of the lamina cribrosa (LC). As ocular biomechanics influence the behavior of the LC, and a lower corneal hysteresis (CH) has been associated to a higher risk of glaucomatous optic nerve damage, in this study we compared ocular biomechanics of iNPH patients with healthy subjects. METHODS:  Twenty-four eyes of 24 non-shunted iNPH patients were prospectively recruited. Ocular biomechanical properties were investigated using the ocular response analyzer (Reichert Instruments) for the calculation of the CH, corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). Results were compared with those of 25 eyes of 25 healthy subjects. RESULTS:  In iNPH eyes, the median CH value and interquartile range (IQR) were 9.7 mmHg (7.8-10) and 10.6 mmHg (9.3-11.3) in healthy controls (p = 0.015). No significant differences were found in IOPcc [18.1 mmHg (14.72-19.92) vs. 16.4 mmHg (13.05-19.6)], IOPg [15.4 mmHg (12.82-19.7) vs. 15.3 mmHg (12.55-17.35)], and CRF [9.65 mmHg (8.07-11.65) vs. 10.3 mmHg (9.3-11.5)] between iNPH patients and controls. CONCLUSIONS:  In iNPH patients, the CH was significantly lower compared to healthy subjects. This result suggests that ocular biomechanical properties may potentially contribute to the risk of development of glaucomatous optic nerve damage in iNPH patients.


Assuntos
Glaucoma de Ângulo Aberto , Hidrocefalia de Pressão Normal , Traumatismos do Nervo Óptico , Humanos , Hidrocefalia de Pressão Normal/complicações , Pressão Intraocular , Tonometria Ocular/métodos , Córnea/fisiologia , Fenômenos Biomecânicos , Elasticidade
7.
Prog Retin Eye Res ; 99: 101234, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38176611

RESUMO

The cornea, as a dynamic and responsive tissue, constantly interacts with mechanical forces in order to maintain its structural integrity, barrier function, transparency and refractive power. Cells within the cornea sense and respond to various mechanical forces that fundamentally regulate their morphology and fate in development, homeostasis and pathophysiology. Corneal cells also dynamically regulate their extracellular matrix (ECM) with ensuing cell-ECM crosstalk as the matrix serves as a dynamic signaling reservoir providing biophysical and biochemical cues to corneal cells. Here we provide an overview of mechanotransduction signaling pathways then delve into the recent advances in corneal mechanobiology, focusing on the interplay between mechanical forces and responses of the corneal epithelial, stromal, and endothelial cells. We also identify species-specific differences in corneal biomechanics and mechanotransduction to facilitate identification of optimal animal models to study corneal wound healing, disease, and novel therapeutic interventions. Finally, we identify key knowledge gaps and therapeutic opportunities in corneal mechanobiology that are pressing for the research community to address especially pertinent within the domains of limbal stem cell deficiency, keratoconus and Fuchs' endothelial corneal dystrophy. By furthering our understanding corneal mechanobiology, we can contextualize discoveries regarding corneal diseases as well as innovative treatments for them.


Assuntos
Distrofia Endotelial de Fuchs , Ceratocone , Animais , Mecanotransdução Celular , Células Endoteliais , Córnea/fisiologia
8.
Invest Ophthalmol Vis Sci ; 65(1): 11, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38170539

RESUMO

Purpose: Smoking may influence measured IOP through an effect on corneal biomechanics, but it is unclear whether this factor translates into an increased risk for glaucoma. This study aimed to examine the association of cigarette smoking with corneal biomechanical properties and glaucoma-related traits, and to probe potential causal effects using Mendelian randomization (MR). Methods: Cross-sectional analyses within the UK Biobank (UKB) and Canadian Longitudinal Study on Aging (CLSA) cohorts. Multivariable linear and logistic regression models were used to assess associations of smoking (status, intensity, and duration) with corneal hysteresis (CH), corneal resistance factor, IOP, inner retinal thicknesses, and glaucoma. Two-sample MR analyses were performed. Results: Overall, 68,738 UKB (mean age, 56.7 years; 54.7% women) and 22 845 CLSA (mean age, 62.7 years; 49.1% women) participants were included. Compared with nonsmokers, smokers had a higher CH (UKB, +0.48 mm Hg; CLSA, +0.57 mm Hg; P < 0.001) and corneal resistance factor (UKB, +0.47 mm Hg; CLSA, +0.60 mm Hg; P < 0.001) with evidence of a dose-response effect in both studies. Differential associations with Goldmann-correlated IOP (UKB, +0.25 mm Hg; CLSA, +0.36 mm Hg; P < 0.001) and corneal-compensated IOP (UKB, -0.28 mm Hg; CLSA, -0.32 mm Hg; P ≤ 0.001) were observed. Smoking was not associated with inner retinal thicknesses or glaucoma status in either study. MR provided evidence for a causal effect of smoking on corneal biomechanics, especially higher CH. Conclusions: Cigarette smoking seems to increase corneal biomechanical resistance to deformation, but there was little evidence to support a relationship with glaucoma. This outcome may result in an artefactual association with measured IOP and could account for discordant results with glaucoma in previous epidemiological studies.


Assuntos
Glaucoma de Ângulo Aberto , Glaucoma , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Canadá/epidemiologia , Córnea/fisiologia , Estudos Transversais , Glaucoma/epidemiologia , Glaucoma/etiologia , Pressão Intraocular , Estudos Longitudinais , Estudos Prospectivos , Fumar/efeitos adversos , Tonometria Ocular , Análise da Randomização Mendeliana
9.
J Glaucoma ; 33(3): 183-188, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37748090

RESUMO

PRCIS: Use of the Ocular Response Analyzer (ORA) as a screening tonometer in clinical practice yielded reliable measurements in over 80% of eyes screened. Including corneal hysteresis (CH) data in screening may improve the accuracy of glaucoma detection. PURPOSE: To examine measurement reliability when the ORA is used as a screening tonometer, and to compare CH measurements in eyes with and those without glaucomatous changes in the fundus. PATIENTS AND METHODS: 1488 eyes of 747 patients (mean age: 53.5 ± 20.4 y, range: 6-94 y) underwent intraocular pressure (IOP) measurement using ORA as screening. The percentage of eyes with a waveform score ≥6, the recommended threshold indicating reliability, was calculated. Eyes that had waveform score ≥6 and had undergone fundus photography and optical coherence tomography were assessed for the presence or absence of glaucomatous changes in fundus from optical coherence tomography and fundus images, and CH was compared between the 2 groups. RESULTS: Mean ± SD (range) of ORA measurements were: Goldmann-correlated IOP 14.9 ± 4.8 (1.0-63.2) mm Hg, corneal-compensated IOP 16.2 ± 4.7 (3.2-73.6) mm Hg, CH 9.7 ± 1.5 (0.0-20.6) mm Hg, and waveform score 7.3 ± 1.5 (0.1-9.7). Eighty-four percent of eyes had a waveform score ≥6. Among 192 eyes (127 patients, aged 53.5 ± 18.0 y) with waveform score ≥6 and evaluable for glaucomatous changes in the fundus, 53 eyes were determined as positive and 139 eyes as negative. CH was 9.6 ± 1.4 (6.8-13.3) mm Hg in the positive group and 10.2 ± 1.2 (6.9-13.3) mm Hg in the negative group, and was significantly lower in the positive group ( P =0.003). CONCLUSION: When using ORA as a screening tonometer, reliable results were obtained in ~80% of the eyes. CH was lower in the glaucomatous change-positive group compared with the glaucomatous change-negative group, but the ranges overlapped between the 2 groups.


Assuntos
Glaucoma , Pressão Intraocular , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Tonometria Ocular/métodos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Córnea/fisiologia
10.
Prostaglandins Other Lipid Mediat ; 170: 106802, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38036037

RESUMO

The transparent cornea is the most densely innervated tissue in the body, primarily by sensory nerves originating from the trigeminal ganglia (TG). Damage to corneal nerves reduces sensitivity and tear secretion and results in dry eye. Consequently, ocular pain, for which no satisfactory therapies exist, arises in many cases. Treatment of injured corneas with pigment epithelium-derived factor (PEDF) combined with docosahexaenoic acid (DHA) stimulates nerve regeneration in models of refractive surgery, which damages nerves. The mechanism involves the synthesis of a stereoisomer of resolvin D6 (R,R-RvD6) formed after incorporating DHA into membrane lipids. Activation of a PEDF receptor (PEDF-R) with phospholipase activity releases DHA to synthesize the new resolvin isomer, which is secreted via tears. Topical treatment of mice corneas with R,R-RvD6 shows higher bioactivity in regenerating nerves and increasing sensitivity compared to PEDF+DHA. It also stimulates a transcriptome in the TG that modulates genes involved in ocular pain. Our studies suggest an important therapeutic role for R,R-RvD6 in regenerating corneal nerves and decreasing pain resulting from dry eye.


Assuntos
Córnea , Síndromes do Olho Seco , Camundongos , Animais , Córnea/inervação , Córnea/fisiologia , Córnea/cirurgia , Ácidos Docosa-Hexaenoicos/farmacologia , Ácidos Docosa-Hexaenoicos/uso terapêutico , Regeneração Nervosa/fisiologia , Dor/tratamento farmacológico , Síndromes do Olho Seco/tratamento farmacológico
11.
J Optom ; 17(2): 100488, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37918060

RESUMO

PURPOSE: As ocular dryness and glaucoma are more prevalent with increasing age, understanding how the tear film affects tonometry is important. The present study aims to understand the impact that changes in the tear film have on intraocular pressure (IOP), corneal hysteresis, and corneal resistance factor measurements. METHODS: Cross-sectional research was conducted and 37 patients were assessed. The tear film lipid layer and the non-invasive break-up time (NIBUT) were evaluated using the Tearscope Plus (Keeler, Windsor, UK). Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire. IOP was measured using rebound tonometry and the Ocular Response Analyzer (ORA, Reichert). Corneal biomechanical properties were measured using ORA. RESULTS: It was found that an increase in the IOP measured with the iCare was directly correlated with the subclass that evaluated symptomatology associated with environmental factors (r = 0.414, p<0.05, Spearman). Goldmann-correlated IOP (IOPg) and Corneal-compensated IOP (IOPcc) values were statistically significantly different between the various interferometric patterns (p<0.05). It was also found that an increase in the corneal biomechanical properties measured with ORA was directly correlated with the overall scores obtained when using the OSDI and some of its subclasses. CONCLUSIONS: Tear film interferometric patterns were shown to have some impact on the IOP measured using ORA. The IOP measured with iCare seems to be related to the symptomatology obtained from OSDI. Corneal biomechanical properties were related to the OSDI total score and some of its subclasses. An increase in symptomatology was associated with an increase in the measured biomechanical properties of the cornea.


Assuntos
Glaucoma , Pressão Intraocular , Humanos , Estudos Transversais , Tonometria Ocular , Córnea/fisiologia , Fenômenos Biomecânicos
12.
Biomech Model Mechanobiol ; 23(3): 709-720, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38129672

RESUMO

We present a patient-specific finite element model of the human cornea that accounts for the presence of the epithelium. The thin anterior layer that protects the cornea from the external actions has a scant relevance from the mechanical point of view, and it has been neglected in most numerical models of the cornea, which assign to the entire cornea the mechanical properties of the stroma. Yet, modern corneal topographers capture the geometry of the epithelium, which can be naturally included into a patient-specific solid model of the cornea, treated as a multi-layer solid. For numerical applications, the presence of a thin layer on the anterior cornea requires a finer discretization and the definition of two constitutive models (including the corresponding properties) for stroma and epithelium. In this study, we want to assess the relevance of the inclusion of the epithelium in the model of the cornea, by analyzing the effects in terms of uncertainties of the mechanical properties, stress distribution across the thickness, and numerical discretization. We conclude that if the epithelium is modeled as stroma, the material properties should be reduced by 10%. While this choice represents a sufficiently good approximation for the simulation of in vivo mechanical tests, it might result into an under-estimation of the postoperative stress in the simulation of refractive surgery.


Assuntos
Córnea , Epitélio Corneano , Análise de Elementos Finitos , Estresse Mecânico , Humanos , Córnea/fisiologia , Epitélio Corneano/fisiologia , Modelos Biológicos , Fenômenos Biomecânicos , Simulação por Computador , Análise Numérica Assistida por Computador
13.
J Neurotrauma ; 41(7-8): 985-999, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38115600

RESUMO

Mild traumatic brain injury (mTBI) is often accompanied by neurological and ocular symptoms that involve trigeminal nerve pathways. Laser-induced shock wave (LISW) was applied to the skull of male rats as a model for mTBI, while behavioral and neural recording methods were used to assess trigeminal function. The LISW caused greater eye wiping behavior to ocular instillation of hypertonic saline (Sham = 4.83 ± 0.65 wipes/5 min, LISW = 12.71 ± 1.89 wipes/5 min, p < 0.01) and a marked reduction in the time spent in bright light consistent with enhanced periocular and intraocular hypersensitivity, respectively (Sham = 16.3 ± 5.6 s, LISW = 115.5 ± 27.3 s, p < 0.01). To address the early neural mechanisms of mTBI, single trigeminal brainstem neurons, identified by activation to corneal or dural mechanical stimulation, were recorded in trigeminal subnucleus interpolaris/caudalis (Vi/Vc) and trigeminal subnucleus caudalis/upper cervical cord (Vc/C1) regions. The LISW caused marked sensitization to hypertonic saline and to exposure to bright light in neurons of both regions (p < 0.05). Laser speckle imaging revealed an increase in meningeal arterial blood flow to bright light after LISW (Sham = 4.7 ± 2.0 s, LISW = 469.0 ± 37.9 s, p < 0.001). Local inhibition of synaptic activity at Vi/Vc, but not at Vc/C1, by microinjection of CoCl2, prevented light-evoked increases in meningeal blood flow in LISW-treated rats. By contrast, topical meningeal application of phenylephrine significantly reduced light-evoked responses of Vi/Vc and Vc/C1 neurons. These data suggested that neurons in both regions became sensitized after LISW and were responsive to changes in meningeal blood flow. Neurons at the Vi/Vc transition and at Vc/C1, however, likely serve different roles in mediating the neurovascular and sensory aspects of mTBI.


Assuntos
Concussão Encefálica , Ratos , Masculino , Animais , Ratos Sprague-Dawley , Concussão Encefálica/metabolismo , Neurônios/metabolismo , Córnea/inervação , Córnea/fisiologia , Tronco Encefálico
14.
Comp Med ; 73(5): 373-377, 2023 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-38087405

RESUMO

Large animal models are essential to research in facial paralysis, face transplant, craniofacial surgery, and ophthalmology. Pigs are a well-studied species with high similarity to human anatomy and physiology for these research areas. However, in contrast to cats and dogs protecting the cornea and eye is difficult in swine due to the inability to use an Elizabethan collar (E-collar) and the complexity of placing and maintaining a temporary tarsorrhaphy for corneal protection due to the strength of the pig levator muscle. This study presents an effective method to provide corneal and eye protection in the domestic swine for at least 50 d. Furthermore, protection of the eye and face is achieved through the innovative use of a modified ophthalmologic face shield. The findings from this study will advance large animal research in these fields, enabling innovation in surgery and tissue engineering in areas of both craniofacial and ophthalmologic research.


Assuntos
Córnea , Músculos , Humanos , Suínos , Gatos , Animais , Cães , Córnea/cirurgia , Córnea/anatomia & histologia , Córnea/fisiologia , Modelos Animais
15.
Exp Eye Res ; 237: 109718, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37952725

RESUMO

The purpose of this study was to investigate the depth-dependent biomechanical properties of the human corneal stroma under uniaxial tensile loading. Human stroma samples were obtained after the removal of Descemet's membrane in the course of Descemet's membrane endothelial keratoplasty (DMEK) transplantation. Uniaxial tensile tests were performed at three different depths: anterior, central, and posterior on 2 × 6 × 0.15 mm strips taken from the central DMEK graft. The measured force-displacement data were used to calculate stress-strain curves and to derive the tangent modulus. The study showed that mechanical strength decreased significantly with depth. The anterior cornea appeared to be the stiffest, with a stiffness approximately 18% higher than that of the central cornea and approximately 38% higher than that of the posterior layer. Larger variations in mechanical response were observed in the posterior group, probably due to the higher degree of alignment of the collagen fibers in the posterior sections of the cornea. This study contributes to a better understanding of the biomechanical tensile properties of the cornea, which has important implications for the development of new treatment strategies for corneal diseases. Accurate quantification of tensile strength as a function of depth is critical information that is lacking in human corneal biomechanics to develop numerical models and new treatment methods.


Assuntos
Córnea , Doenças da Córnea , Humanos , Córnea/fisiologia , Substância Própria/fisiologia , Doenças da Córnea/cirurgia , Fenômenos Mecânicos , Resistência à Tração , Lâmina Limitante Posterior/cirurgia
16.
Invest Ophthalmol Vis Sci ; 64(14): 12, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37938935

RESUMO

Purpose: The purpose of this study was to analyze the differences in corneal sensory nerve functionality in young asymptomatic (CL-A) and symptomatic (CL-S) contact lens (CL) users. Methods: CL wearers (23.8 ± 1.0 years, n = 31) were classified as CL-S with an Ocular Surface Disease Index (OSDI) ≥ 13 (n = 14) or CL-A. Users of eye glasses (EG; 24.5 ± 0.8 years, n = 29) with OSDI < 13 participated as controls. The sensations evoked by mechanical, chemical (gas esthesiometer), and cold (4°C saline drops) stimuli were measured using the Visual Analogue Scales (VASs). Moreover, tear volume, tear break up time (TBUT), blinking frequency (BF), and ocular surface temperature (OST; IR thermography) were also measured. Results: Mechanical and chemical stimuli produced similar scores in the CL-A and EG participants, although the CL-A subjects referred to stronger irritation (p < 0.05). Likewise, the VAS intensity in response to cold stimuli did not differ between CL-A and EG subjects, while the ability to detect cold was significantly worse in CL-S users (p < 0.05). CL-A users had a similar tear volume, a higher BF (p < 0.01) and shorter TBUT (p < 0.001) to EG wearers, and blinking and TBUT were also altered significantly in CL-S users (p < 0.01). Interestingly, the OST was significantly lower in CL-A users (p < 0.05) than in EG wearers, but not in CL-S users. Conclusions: Using CLs modifies corneal sensitivity, blinking and tearing in young volunteers. Even if they have yet to develop clinical signs of inflammation, they display changes in corneal sensitivity consistent with the sensitization of corneal nociceptors and the inhibition cold thermoreceptors, phenomena that occur under inflammatory conditions. The differences in corneal sensitivity and OST between CL-A and CL-S users could reflect the extent of nerve damage and inflammation at the ocular surface.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Síndromes do Olho Seco , Doenças do Aparelho Lacrimal , Humanos , Córnea/fisiologia , Piscadela , Lágrimas , Inflamação , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/etiologia
17.
Cont Lens Anterior Eye ; 46(6): 102067, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37863714

RESUMO

PURPOSE: To investigate the long-term influence of scleral lens (SL) wear on corneal biomechanical properties and intraocular pressure (IOP) in irregular and regular corneas. Secondary goal comprised evaluate the fluid reservoir (FR) thickness overtime and correlate it with the changes in corneal biomechanical parameters and IOP. METHODS: Seventy (70) eyes with irregular corneas (IC Group) and 21 eyes with regular corneas (RC Group) were fitted with 16.4 mm SL and wore the lenses for 12 months. Corrected IOP (IOPcc), Goldmann equivalent IOP (IOPg) and corneal biomechanical parameters (Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF)) were measured with Ocular Response Analyzer. Slit lamp images were analyzed with ImageJ software to assess FR thickness overtime. Measurements were taken at lens dispensing visit prior lens wear (LDV1) and after 60 min of lens wear (LDV2) and at 1, 6 and 12-month follow-up visits. Measurements were done immediately after lens removal. RESULTS: There were no statistically significant differences on IOPcc, IOPg, CRF and CH over the follow-up visits in both groups. Mean IOPcc and IOPg fluctuations overtime were clinically insignificant and below 1 mmHg in both groups. IOPg, CH and CRF were significantly lower on IC Group (p < 0.001), although no statistically significant differences were found between groups for IOPcc. Regarding FR thickness, statistically significant differences were found over the follow-up on both groups, with a mean decrease of 186.29 µm on IC Group and 175.32 µm on RC Group (p < 0.001). Statistically significant moderate to high negative correlations between FR and IOPg, CRF and CH were found only in the RC Group. CONCLUSIONS: Long-term SL wear was not associated to changes in corneal biomechanical parameters neither on IOP as measured after lens removal. Besides IOP measurement without SL removal, more studies are needed to investigate the potential relationship with SL fitting characteristics (namely FR thickness).


Assuntos
Oftalmopatias , Pressão Intraocular , Humanos , Seguimentos , Estudos Prospectivos , Tonometria Ocular , Córnea/fisiologia , Fenômenos Biomecânicos , Elasticidade
18.
Optom Vis Sci ; 100(10): 688-696, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639554

RESUMO

SIGNIFICANCE: Clinicians and researchers will have evidence whether intereye differences confound clinical measurements of intraocular pressure or of ocular biomechanical parameters. PURPOSE: The purpose of this study was to determine whether intraocular pressure and biomechanical parameters, as measured by the Ocular Response Analyzer (ORA) and by Cornea Visualization with Scheimpflug Technology (CorVis ST), are different between the first and second eye measured. METHODS: Intraocular pressure and biomechanical parameters were collected from both eyes of healthy participants (N = 139). The ORA measured corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, and corneal hysteresis. The CorVis ST measured biomechanically corrected intraocular pressure, stiffness parameter at first applanation, and stiffness parameter at highest concavity. For each measurement, a paired t test compared the value of the first eye measured against that of the second eye measured. RESULTS: For the ORA, Goldmann-correlated intraocular pressure was significantly higher ( P = .001) in the first eye (14.8 [3.45] mmHg) than in the second eye (14.3 [3.63] mmHg). For the CorVis ST, biomechanically corrected intraocular pressure was significantly higher ( P < .001) in the second eye (14.7 [2.14] mmHg) than in the first eye (14.3 [2.11] mmHg). Stiffness parameter at first applanation (intereye difference, 6.85 [9.54] mmHg/mm) was significantly ( P < .001) higher in the first eye than in the second eye. Stiffness parameter at highest concavity was significantly higher ( P = .01) in the second eye (14.3 [3.18] mmHg/mm) than in the first eye (14.0 [3.13] mmHg/mm). CONCLUSIONS: Although there were statistically significant intereye differences in intraocular pressure and in biomechanical parameters for both devices, the variations were small and thus unlikely to affect clinical outcomes.


Assuntos
Oftalmopatias , Pressão Intraocular , Humanos , Fenômenos Biomecânicos , Tonometria Ocular , Córnea/fisiologia
19.
Medicine (Baltimore) ; 102(32): e34580, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37565903

RESUMO

BACKGROUND: Small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) have been extensively studied as the main surgical methods for corneal refractive surgery. However, there is no consensus on whether SMILE is superior to FS-LASIK in corneal biomechanics. Therefore, this systematic review and meta-analysis used the results of ocular response analyzer and corvis ST to explore whether SMILE is superior to FS-LASIK in corneal biomechanics. METHODS: The literature was searched in PubMed, EMBASE, and Controlled Trials Register databases. The Cochrane Collaboration's "risk of bias" tool was used to evaluate the quality of the included randomized clinical trials, and the Newcastle-Ottawa Scale was used to evaluate the included non-randomized controlled trials. The results were analyzed using Revman 5.3. RESULTS: Sixteen studies (3 randomized clinical trials and 13 non-randomized controlled trials) were included in this meta-analysis. There was no statistical difference in corneal biomechanics between SMILE and FS-LASIK in corneal hysteresis [mean difference (MD), 0.20; 95% confidence interval (CI): -0.09, 0.49; P = .18] and corneal resistant factor (MD, 0.31; 95% CI: -0.09, 0.71; P = .13), A1 time (MD, -0.02; 95% CI: -0.11, 0.07; P = .66), A1 length (MD, 0.01; 95% CI: -0.01, 0.03; P = .42), A1 velocity (MD, 0.00; 95% CI: -0.01, 0.01; P = .85), A2 velocity (MD, -0.01; 95% CI: -0.11, 0.09; P = .86), HC time (MD, 0.12; 95% CI: -0.13, 0.38; P = .35), The stiffness parameter at first applanation (MD, -7.91; 95% CI: -17.96, 2.14; P = .12), The ratio between the deformation amplitude 2 mm away from apex and the apical deformation (MD, 0.01; 95% CI: -0.26, 0.27; P = .96). CONCLUSION: A comprehensive assessment of the parameters of ocular response analyzer and corvis ST showed that SMILE is not superior to LASIK in corneal biomechanics 3 months post-surgery.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Ferida Cirúrgica , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Fenômenos Biomecânicos , Miopia/cirurgia , Córnea/cirurgia , Córnea/fisiologia , Estudos Prospectivos , Ferida Cirúrgica/cirurgia , Substância Própria/cirurgia
20.
J Cataract Refract Surg ; 49(8): 790-794, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37482665

RESUMO

PURPOSE: To assess the inter-observer agreement and reliability of central topography (CT) of IOL Master 700 with that of Pentacam HR, as a screening tool for determining the suitability for premium (toric, monofocal and presbyopia correcting) intraocular lens (IOL) implants. SETTING: Nethradhama Superspeciality Eye Hospital, Bangalore, India. METHOD: 200 eyes of eligible patients undergoing unilateral or bilateral phacoemulsification with premium IOL's were included in the study. Preoperatively, IOL Master 700 CT and Pentacam scans were performed for corneal topography evaluation. 2 experienced clinicians were randomised to interpret the axial map of either of the scans at a time and their responses were then enclosed in an envelope, and forwarded to a third observer for analysis. If there was a conflict, final decision was based on the interpretation of the Pentacam scan. RESULTS: Of the total scans interpreted by the 2 observers, 77.5% (n = 155) showed agreement whereas 22.5% (n = 45) showed disagreement. The sensitivity, specificity, positive predictive value and negative predictive value (NPV) of IOL Master 700 CT in diagnosing irregular corneas when compared with Pentacam HR, was 72.73%, 78.09%, 29.09% and 95.86% respectively. The Cohen's κ inter-observer agreement value was 0.44, signifying a moderate degree of agreement, which was statistically significant (P < .00). CONCLUSIONS: High NPV of IOL Master CT suggested that the device efficiently ruled out irregular corneas, while any suspicious scan should be confirmed with Pentacam HR or a similar device for appropriate decision-making regarding premium IOL selection. TRIAL REGISTRATION NUMBER: CTRI/2021/11/038053.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular/métodos , Reprodutibilidade dos Testes , Variações Dependentes do Observador , Índia , Córnea/diagnóstico por imagem , Córnea/fisiologia , Facoemulsificação/métodos , Tomografia , Astigmatismo/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA