Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.057
Filtrar
1.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(9): 989-991, 2024 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-39380523

RESUMO

Extracorporeal membrane oxygenation (ECMO) is an important treatment for extracorporeal cardiopulmonary life support for clinically critical patients. Currently, ECMO tubing is commonly fixed by tie-wraps or tourniquets, which have shortcomings such as easy loosening and potential damage to the tubing. Improper fixation of the catheter can lead to a series of adverse events, such as accidental disconnection of the tubing, rupture of the tubing, tubing folding, and air ingress into the tubing. In order to overcome the above problems, the research team of Zhongda Hospital, Southeast University invented a device for ECMO line fixation and obtained a national utility model patent of China (patent number: ZL 2019 2 2282849.3). The tool is mainly composed of several devices, including a line fixation clamp, a clip fixation device, and a base plate, which is uniquely designed and easy to operate. During ECMO therapy, this device ensures effective stabilization of the ECMO tubing, preventing unexpected incidents due to catheter loosening and facilitating the observation of ECMO catheter insertion markings. Pipeline can be effectively fixed to avoid the occurrence of accidents due to the loosening of the catheter, and at the same time, it is convenient to observe the placement scale of the ECMO catheter. The novelty and uniqueness of the fixation device materials also effectively prevent the occurrence of pressure injuries during its use.


Assuntos
Desenho de Equipamento , Oxigenação por Membrana Extracorpórea , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Catéteres/efeitos adversos
3.
A A Pract ; 18(7): e01822, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39037106

RESUMO

Peripheral nerve blocks are typically avoided for high-speed tibial plateau fractures due to their ability to mask the paresthesias and pain associated with the feared complication of acute compartment syndrome (ACS). We present a case in which sciatic nerve and adductor canal catheters were placed utilizing low-volume infusions allowing for neurovascular assessment. These catheters served as a valuable portion of the multi-modal pain regimen in this patient with a Schatzker VI tibial plateau fracture.


Assuntos
Bloqueio Nervoso , Nervo Isquiático , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Nervo Isquiático/lesões , Masculino , Catéteres/efeitos adversos , Pessoa de Meia-Idade , Síndromes Compartimentais/etiologia , Síndromes Compartimentais/cirurgia , Fraturas do Planalto Tibial
5.
Can J Anaesth ; 71(7): 1037-1042, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38750348

RESUMO

PURPOSE: Spinal epidural hematoma (SEH) is a rare yet significant complication associated with neuraxial anesthesia. Here, we present the case of a 74-yr-old male who underwent open repair of an abdominal aortic aneurysm. Following the removal of an epidural catheter, the patient developed anterior spinal cord syndrome due to an SEH despite having a normal coagulation profile. CLINICAL FEATURES: This patient's neurologic presentation was marked by a loss of motor function while maintaining fine touch sensation distal to the spinal cord injury. Initial truncal computed tomography (CT) angiography failed to detect vascular compromise or diagnose the SEH. Subsequently, delayed magnetic resonance imaging (MRI) revealed a multilevel thoracic epidural hematoma, spinal cord infarction, and ischemia. Immediate surgical decompression was performed, but unfortunately, the patient had a poor outcome. CONCLUSION: Anterior spinal cord syndrome (ASCS) represents an uncommon neurologic manifestation of SEH, which is typically characterized by a triad of back pain and sensory and motor deficits. Although the initial CT scan was necessary to diagnose the postvascular surgery complication, it did not immediately detect the SEH. In cases of ASCS subsequent to thoracic epidural placement and removal, MRI is the preferred imaging modality for precise diagnosis and assessment of the need for surgical intervention. Despite adherence to anticoagulation guidelines, patients undergoing neuraxial anesthesia may face an elevated risk of developing SEH. Health care professionals should remain vigilant in monitoring for neurologic abnormalities following epidural catheter insertion or removal, particularly in the context of vascular surgery.


RéSUMé: OBJECTIF: L'hématome péridural rachidien est une complication rare mais importante associée à l'anesthésie neuraxiale. Nous présentons ici le cas d'un homme de 74 ans qui a bénéficié d'une réparation ouverte d'un anévrisme de l'aorte abdominale. Après le retrait d'un cathéter péridural, le patient a développé un syndrome médullaire antérieur dû à un hématome péridural rachidien malgré un profil de coagulation normal. CARACTéRISTIQUES CLINIQUES: La présentation neurologique de ce patient était marquée par une perte de la fonction motrice tout en conservant une sensation de toucher fine distale à la lésion médullaire. L'angiographie initiale par tomodensitométrie (TDM) n'a pas permis de détecter d'atteinte vasculaire ni de diagnostiquer un hématome péridural rachidien. Par la suite, une imagerie par résonance magnétique (IRM) retardée a révélé un hématome péridural thoracique à plusieurs niveaux, un infarctus médullaire et une ischémie. Une décompression chirurgicale immédiate a été réalisée, mais malheureusement, l'issue a été mauvaise pour le patient. CONCLUSION: Le syndrome médullaire antérieur représente une manifestation neurologique peu fréquente de l'hématome péridural rachidien, qui se caractérise généralement par une triade de maux de dos et de déficits sensoriels et moteurs. Bien que la tomodensitométrie initiale ait été nécessaire pour diagnostiquer la complication chirurgicale post-vasculaire, elle n'a pas immédiatement détecté l'hématome péridural rachidien. Dans les cas de syndromes médullaires antérieurs consécutifs à la pose et au retrait d'un cathéter péridural thoracique, l'IRM est la modalité d'imagerie privilégiée pour un diagnostic précis et une évaluation de la nécessité d'une intervention chirurgicale. Malgré le respect des directives d'anticoagulation, les patient·es bénéficiant d'une anesthésie neuraxiale peuvent faire face à un risque élevé de développer un hématome péridural rachidien. Les professionnel·les de la santé doivent demeurer vigilant·es dans le monitorage des anomalies neurologiques à la suite de l'insertion ou du retrait d'un cathéter péridural, en particulier dans le contexte d'une chirurgie vasculaire.


Assuntos
Anestesia Epidural , Hematoma Epidural Espinal , Humanos , Masculino , Hematoma Epidural Espinal/etiologia , Hematoma Epidural Espinal/diagnóstico por imagem , Idoso , Anestesia Epidural/efeitos adversos , Imageamento por Ressonância Magnética , Aneurisma da Aorta Abdominal/cirurgia , Catéteres/efeitos adversos , Remoção de Dispositivo/métodos , Descompressão Cirúrgica/métodos , Síndrome
6.
Prenat Diagn ; 44(8): 971-978, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38743216

RESUMO

OBJECTIVE: We report on the 1-year outcomes of fetuses who underwent thoracoamniotic shunting (TAS) with a double-basket catheter for fetal hydrothorax (FHT) using a national post-marketing surveillance registry. METHODS: This surveillance study was conducted for cases enrolled between 2011 and 2019. Preoperative, operative, and postoperative findings and outcomes had to be reported through the national surveillance website. RESULTS: Forty-three institutes enrolled 295 patients. In 60 patients, associated abnormalities were diagnosed after birth. Among the 235 patients with isolated hydrothorax, the survival rate at 1 year of age was 70.5%. Among these patients, 89% did not require oxygen or other respiratory support. The 1-year survival rate in complicated cases was 27%. Trisomy 21 was the most common associated problem (40%). Catheter associated problems, including dislocation (25%), obstruction (24%), and preterm rupture of the membranes (6%) were observed, but there were no severe maternal complications. TAS before 29.5 weeks of gestation (odds ratio [OR] 0.16) and skin edema and ascites (OR 0.06) were risk factors for death at one year, whereas appropriate shunt location for >28 days (OR 4.2) was a protective factor. CONCLUSION: We report a favorable survival rate in fetuses with isolated FHT treated with this double-basket catheter.


Assuntos
Hidrotórax , Sistema de Registros , Humanos , Feminino , Gravidez , Sistema de Registros/estatística & dados numéricos , Hidrotórax/cirurgia , Hidrotórax/epidemiologia , Hidrotórax/etiologia , Adulto , Catéteres/efeitos adversos , Vigilância de Produtos Comercializados/estatística & dados numéricos , Terapias Fetais/métodos , Terapias Fetais/estatística & dados numéricos , Terapias Fetais/instrumentação , Terapias Fetais/efeitos adversos , Recém-Nascido , Doenças Fetais/epidemiologia , Doenças Fetais/cirurgia
8.
Sci Rep ; 14(1): 9111, 2024 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643229

RESUMO

Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) may be useful in treating exsanguinating trauma patients. This study seeks to compare rates of success, complications and time required for vascular access between ultrasound-guidance and surgical cut-down for femoral sheath insertion as a prospective observational case control study. Participating clinicians from either trauma surgery or anesthesiology were allocated to surgical cut-down or percutaneous ultrasound-guided puncture on a 1:1 ratio. Time spans to vessel identification, successful puncture, and balloon inflation were recorded. 80 study participants were recruited and allocated to 40 open cut-down approaches and 40 percutaneous ultrasound-guided approaches. REBOA catheter placement was successful in 18/40 cases (45%) using a percutaneous ultrasound guided technique and 33/40 times (83%) using the open cut-down approach (p < 0.001). Median times [in seconds] compared between percutaneous ultrasound-guided puncture and surgical cut-down were 36 (18-73) versus 117(56-213) for vessel visualization (p < 0.001), 136 (97-175) versus 183 (156-219) for vessel puncture (p < 0.001), and 375 (240-600) versus 288 (244-379) for balloon inflation (p = 0.08) overall. Access to femoral vessels for REBOA catheter placement is safer when performed by cut-down and direct visualization but can be performed faster by an ultrasound-guided technique when vessels can be identified clearly and rapidly.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Humanos , Estudos de Casos e Controles , Procedimentos Endovasculares/métodos , Hemorragia/etiologia , Aorta/diagnóstico por imagem , Aorta/cirurgia , Ressuscitação/métodos , Oclusão com Balão/métodos , Catéteres/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos , Choque Hemorrágico/terapia
9.
J Int Med Res ; 52(4): 3000605241237680, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38606755

RESUMO

Intraventricular haemorrhage (IVH) is a severe and acute type of stroke with a complex pathophysiology and is a therapeutic challenge. This case report described a man in his early 50's diagnosed with IVH by computed tomography (CT). Although bilateral extraventricular drainage (EVD) was undertaken, a postoperative CT scan showed that while the left catheter was correctly positioned, the right catheter had been wrongly inserted into the cisterna ambiens. The procedure was equivalent to simultaneous EVD combined with cisternostomy. As a consequence, the haematoma was rapidly removed, the risk of infection and long-term hydrocephalus was reduced, and prognosis was improved. Large case-control studies or prospective studies are needed to evaluate the safety and effectiveness of this treatment modality.


Assuntos
Hemorragia Cerebral , Hidrocefalia , Humanos , Masculino , Catéteres/efeitos adversos , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/etiologia , Hemorragia Cerebral/cirurgia , Drenagem/métodos , Hidrocefalia/cirurgia , Resultado do Tratamento , Pessoa de Meia-Idade
10.
Ann Biomed Eng ; 52(6): 1554-1567, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38589731

RESUMO

Catheter reaction forces during transcatheter valve replacement (TAVR) may result in injury to the vessel or plaque rupture, triggering distal embolization or thrombosis. In vitro test methods represent the arterial wall using synthetic proxies to determine catheter reaction forces during tracking, but whether they can account for reaction forces within the compliant aortic wall tissue in vivo is unknown. Moreover, the role of plaque inclusions is not well understood. Computational approaches have predicted the impact of TAVR positioning, migration, and leaflet distortion, but have not yet been applied to investigate aortic wall reaction forces and stresses during catheter tracking. In this study, we investigate the role that catheter design and aorta and plaque mechanical properties have on the risk of plaque rupture during TAVR catheter delivery. We report that, for trackability testing, a rigid test model provides a reasonable estimation of the peak reaction forces experienced during catheter tracking within compliant vessels. We investigated the risk of rupture of both the aortic tissue and calcified plaques. We report that there was no risk of diseased aortic tissue rupture based on an accepted aortic tissue stress threshold (4.2 MPa). However, we report that both the aortic and plaque tissue exceed a rupture stress threshold (300 kPa) with and without the presence of stiff and soft plaque inclusions. We also highlight the potential risks associated with shorter catheter tips during catheter tracking and demonstrate that increasing the contact surface will reduce peak contact pressures experienced in the tissue.


Assuntos
Modelos Cardiovasculares , Substituição da Valva Aórtica Transcateter , Substituição da Valva Aórtica Transcateter/efeitos adversos , Humanos , Aorta , Catéteres/efeitos adversos , Placa Aterosclerótica
11.
Medicine (Baltimore) ; 103(15): e37772, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608117

RESUMO

RATIONALE: Retrograde jejunoduodenogastric intussusception refers to invagination of distal small intestine into the stomach. It is extremely rare. It is often associated with displaced feeding catheter in which its balloon tip migrates past the gastric pylorus. The intussusception is triggered by retraction of migrated catheter. It is often accompanied by feeding intolerance or catheter malfunction. This report describes a distinctive case of retrograde jejunoduodenogastric intussusception associated with a fully functioning nonballoon nasojejunal tube. PATIENT CONCERN: A 19-year-old female was presented with repeated vomiting and abdominal distension for 5 days. DIAGNOSIS: An abdominal computerized tomography revealed retrograde jejunoduodenogastric intussusception causing air/fluid-filled gastric distension. Immediate endoscopic examination revealed a loop of small intestine, protruding through the pylorus. Progressed ischemia of the migrated small bowel loop was confirmed. INTERVENTIONS: At laparotomy, a jejunal loop migrating into the duodenum and stomach at the level of the ligament of Treitz was noticed. After manual reduction of migrated bowel, 2 segmental resections of necrotic segment were performed. A feeding jejunostomy was constructed in the proximal jejunum. OUTCOMES: Enteral feeding through the surgically constructed feeding jejunostomy was started on the 5th operative day and the patient was discharged on the 16th postoperative day. LESSONS: When a patient under tube feeding exhibits abrupt intractable gastroesophageal reflux with a sign of catheter migration, we must consider the possibility of catheter-related intussusception. Having a fully functioning feeding catheter with nonballoon tip does not preclude retrograde jejunoduodenogastric intussusception.


Assuntos
Refluxo Gastroesofágico , Intussuscepção , Feminino , Humanos , Recém-Nascido , Adulto Jovem , Adulto , Intussuscepção/etiologia , Intussuscepção/cirurgia , Catéteres/efeitos adversos , Estômago , Vômito
12.
A A Pract ; 18(4): e01771, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38578011

RESUMO

Regional anesthesia nerve blocks are increasingly used for patients undergoing cardiac surgery as part of multimodal pain management. Though rare, local anesthetic systemic toxicity (LAST) is a severe complication that requires vigilant monitoring. We present a case of a postcardiac surgery patient who developed LAST multiple days after surgery from lidocaine via an erector spinae plane catheter. This episode was determined to be a result of impaired lidocaine metabolism from liver shock caused by worsening pulmonary hypertension. Even under continuous monitoring, patients with cardiac or liver dysfunction are at increased risk of complications from local anesthetics.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Bloqueio Nervoso , Humanos , Anestésicos Locais/efeitos adversos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Bloqueio Nervoso/efeitos adversos , Lidocaína/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Catéteres/efeitos adversos
13.
ASAIO J ; 70(10): 853-860, 2024 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446827

RESUMO

Prevention of limb ischemia in patients with venoarterial extracorporeal membrane oxygenation (VA-ECMO) is primarily achieved through the use of distal perfusion catheters (DPC). Our objective was to assess the role of DPC, and specifically the size of the catheter, in reducing the incidence of acute limb ischemia (ALI) through a meta-analysis. Seventeen studies met criteria for analysis. Pooled analysis included a total of 2,040 patients, of which 904 patients received ECMO with DPC and 1,136 patients underwent ECMO without DPC. Compared with ECMO alone, ECMO with DPC, regardless of size, significantly decreased ALI (relative risk [RR]: 0.49, 95% confidence interval [CI]: 0.31-0.77; p = 0.002). When comparing reactive versus prophylactic placement of DPC, prophylactic DPC was associated with significantly decreased ALI (RR: 0.41, 95% CI: 0.24-0.71; p = 0.02). No differences in mortality (RR: 0.89, 95% CI: 0.76-1.03; p = 0.12) and bleeding events (RR: 1.43, 95% CI: 0.41-4.96; p = 0.58) were observed between the two groups. This analysis demonstrates that the placement of DPC, if done prophylactically and regardless of size, is associated with a reduced risk of ALI versus the absence of DPC placement, but is not associated with differences in mortality or bleeding events.


Assuntos
Oxigenação por Membrana Extracorpórea , Isquemia , Humanos , Doença Aguda , Catéteres/efeitos adversos , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/instrumentação , Extremidades/irrigação sanguínea , Isquemia/etiologia , Isquemia/prevenção & controle
15.
PLoS One ; 19(3): e0299715, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38536779

RESUMO

OBJECTIVE: This meta-analysis aimed to elucidate the risk factors contributing to catheter-associated bloodstream infection in hemodialysis patients. METHODS: Comprehensive literature searches were conducted in both English and Chinese databases, which encompassed PubMed, Cochrane Library, Embase, CNKI, Wanfang Data, VIP Database and China Biomedical Literature Database. The search timeframe extended from each database's inception to March 8, 2023. Two independent researchers executed literature screening, data extraction, and quality assessment using the Newcastle-Ottawa Scale. Statistical analysis of the data was performed using RevMan 5.3 software, facilitating the identification of significant risk factors associated with catheter-related bloodstream infections in hemodialysis patients. This meta-analysis is registered with PROSPERO under the registration number CRD42023406223. RESULTS: Forty-nine studies were incorporated into this meta-analysis, from which 22 risk factors were examined. Through the analysis, 17 risk factors exhibited statistical significance (P < 0.05): age (OR = 1.52, 95% CI [0.49, 4.68]), diabetes (OR = 2.52, 95% CI [1.95, 3.25]), kidney disease (OR = 3.45, 95% CI [1.71, 6.96]), history of catheter-associated infection (OR = 2.79, 95% CI [1.96, 3.98]), hypertension (OR = 1.43, 95% CI [1.08, 1.91]), dialysis duration (OR = 3.06, 95% CI [1.70, 5.50]), catheter placement site (OR = 1.91, 95%CI [1.35, 2.70]), catheter duration (OR = 2.06, 95% CI [1.17, 3.60]), number of catheterizations (OR = 4.22, 95% CI [3.32, 5.37]), catheter types (OR = 3.83, 95% CI [2.13, 6.87]), CD4+ cells (OR = 0.33, 95% CI [0.18, 0.63]), albumin (ALB, OR = 2.12, 95% CI [1.15, 3.91]), C-reactive protein (CRP, OR = 1.73, 95% CI [1.47, 2.03]), hemoglobin (Hb, OR = 1.48, 95% CI [0.54, 4.07]), procalcitonin (PCT, OR = 1.05, 95% CI [1.03, 1.06]), inadequate hand hygiene (OR = 5.32, 95% CI [1.07, 26.37]), and APACHE II scores (OR = 2.41, 95% CI [1.33, 4.37]). CONCLUSION: This meta-analysis suggests that age, diabetes, kidney disease, history of catheter-associated infection, hypertension, dialysis duration, catheter placement site, catheter duration, number of catheterizations, catheter type, CD4+ cells, albumin, C-reactive protein, hemoglobin, procalcitonin, inadequate hand hygiene, and APACHE II scores significantly influence the incidence of catheter-associated bloodstream infection in hemodialysis patients.


Assuntos
Infecções Relacionadas a Cateter , Diabetes Mellitus , Hipertensão , Nefropatias , Sepse , Humanos , Diálise Renal/efeitos adversos , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Infecções Relacionadas a Cateter/prevenção & controle , Proteína C-Reativa , Pró-Calcitonina , Catéteres/efeitos adversos , Sepse/etiologia , Fatores de Risco , Diabetes Mellitus/etiologia , Hemoglobinas , Hipertensão/complicações , Nefropatias/etiologia
16.
J Cardiothorac Surg ; 19(1): 151, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521937

RESUMO

BACKGROUND: Iatrogenic complications of endovascular treatment for central venous stenosis have not yet been reported. Here we present a case of a patient on maintenance hemodialysis who developed catheter-related superior vena cava syndrome and subsequently suffered from hemorrhagic pericardial tamponade after undergoing percutaneous transluminal angioplasty and stenting. CASE PRESENTATION: A 72-year-old male patient presented with uremia, and had been receiving maintenance hemodialysis for the past five years. The patient initially presented with dysfunction of the dialysis catheter (a cuffed tunneled double-lumen catheter in the right internal jugular vein). Imaging examination revealed a segmental occlusion of the superior vena cava stretching from the distal end of the dialysis catheter up to right atrium entrance, apparent compensatory dilatation of the azygos vein, and abundant subcutaneous collaterals. The patient underwent percutaneous transluminal balloon dilatation and stenting (covered stent) of the superior vena cava in the Cath Lab. During the procedure, with forceful advancement of the guidewire, it was observed to progress for a distance before a "smoke" appeared, and an outward spillage of contrast agent was visible, which suggested a possible vessel puncture leading into the mediastinum. Unfortunately, postoperative hemorrhagic pericardial tamponade occurred and the patient developed cardiogenic shock. He experienced symptoms included chest tightness and breath shortness with a recorded blood pressure of 84/60mmHg. After draining 600 ml of bloody fluid through pericardiocentesis, the patient's symptoms alleviated and his condition improved. CONCLUSIONS: The case emphasizes the need for increased attention to iatrogenic endovascular injuries during catheter placement and endovascular treatment, such as causing pericardial hemorrhage leading to cardiac tamponade.


Assuntos
Tamponamento Cardíaco , Cateterismo Venoso Central , Derrame Pericárdico , Síndrome da Veia Cava Superior , Doenças Vasculares , Masculino , Humanos , Idoso , Síndrome da Veia Cava Superior/etiologia , Síndrome da Veia Cava Superior/cirurgia , Veia Cava Superior , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Cateterismo Venoso Central/efeitos adversos , Diálise Renal/efeitos adversos , Catéteres/efeitos adversos , Doença Iatrogênica
17.
World J Urol ; 42(1): 129, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38460028

RESUMO

PURPOSE: Convective water vapor thermal therapy or "Rezum™" treatment for lower urinary tract symptoms in men with benign prostate hypertrophy require postoperative catheterization to avoid acute urinary retention. Unsuccessful catheter removal is still unpredictable. We, therefore, aimed to identify the risk factors of failed initial trial without catheter (TWOC) after Rezum™ therapy inside a large cohort of patients. METHODS: A retrospective study was conducted on patients who underwent Rezum™ therapy by three referent urologists across two academic hospitals between January 2022 and January 2023. A Foley catheter was systematically placed after therapy for 7 days in all patients before TWOC. Patients characteristics [age, imagery, maximum urinary flow rate (Qmax), postvoid residual (PVR)], and treatment outcomes (International Prostate Symptom Score (IPSS), quality of life (QoL), adverse events) were analyzed at baseline and 3 months from procedure. Failed initial TWOC was defined as the incapacity to pass urine or measured PVR > 300 mL. After univariate selection, the risk factors for TWOC failure were identified using multivariate logistic regression analysis. RESULTS: 216 patients qualified for analysis with 23 (10.6%) failing the first TWOC after 7 days of catheterization. After multivariate logistic regression, only preoperative PVR predicted TWOC failure (OR 1.01; p = 0.007). The cut-off of preoperative PVR increasing this risk was 120 mL (p = 0, 02). CONCLUSION: Over 10% of men undergoing Rezum™ therapy for LUTS/BPH will experience TWOC failure and AUR after 7 days of catheterization. Preoperative PVR seems to be the only independent risk factor of unsuccessful catheter removal.


Assuntos
Hiperplasia Prostática , Retenção Urinária , Masculino , Humanos , Qualidade de Vida , Estudos Retrospectivos , Hiperplasia Prostática/cirurgia , Retenção Urinária/etiologia , Retenção Urinária/terapia , Resultado do Tratamento , Fatores de Risco , Catéteres/efeitos adversos
18.
J Infect Public Health ; 17(5): 825-832, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38537577

RESUMO

BACKGROUND: Catheter-associated urinary tract infections (CAUTIs) are the most common device-associated healthcare-acquired infections and pose a significant burden on patients and healthcare systems worldwide. However, there is a paucity of data on CAUTI epidemiology and microbiology in the Middle East and North Africa (MENA) region, including Lebanon. METHODS: This 14-year retrospective cohort study was conducted at a tertiary care center in Lebanon. It analyzed data on all adult patients diagnosed with CAUTI between January 2009 and December 2022 in intensive care units (ICUs) and between June 2011 and December 2022 in regular units. Incidence rates, urinary catheter utilization ratios, and microbiological profiles were collected and analyzed. RESULTS: A total of 620 CAUTI cases were identified during the study period. The overall CAUTI rate was 2.4 per 1000 catheter-days, with higher rates in ICUs (3.2 per 1000 catheter-days) compared to regular units (1.4 per 1000 catheter-days). No significant changes in the rates were noted despite implementing many interventions. The most common pathogens were Gram-negative bacteria, with Escherichia coli, Pseudomonas aeruginosa, and Klebsiella pneumoniae being predominant. Multidrug-resistant organisms represented 48% of all isolates. Enterobacterales were largely extended-spectrum ß-lactamase (ESBL) producing, and most Acinetobacter baumannii isolates showed multidrug resistance. CONCLUSIONS: This study provides important insights into CAUTI epidemiology and microbiology in a tertiary care center in Lebanon, addressing the knowledge gap in this area in the MENA region. Despite implementing prevention measures, CAUTI rates remained stable over the 14-year period. The findings highlight the need for continuous improvement in infection prevention practices, diagnostic stewardship, and antimicrobial stewardship, especially given the rising threat of antimicrobial resistance. These results can serve as a guide for the development of targeted preventive strategies to reduce the burden of CAUTIs, particularly in low- and middle-income countries where antimicrobial resistance is a major issue.


Assuntos
Anti-Infecciosos , Infecções Relacionadas a Cateter , Infecção Hospitalar , Infecções Urinárias , Adulto , Humanos , Infecções Relacionadas a Cateter/prevenção & controle , Centros de Atenção Terciária , Estudos Retrospectivos , Líbano/epidemiologia , Infecções Urinárias/microbiologia , Unidades de Terapia Intensiva , Catéteres/efeitos adversos , Infecção Hospitalar/microbiologia
19.
A A Pract ; 18(2): e01757, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38373232

RESUMO

We present a case of acute dyspnea due to postoperative oral bleeding after tonsillectomy, wherein a blood clot obscured the laryngeal structures to such an extent that no recognizable structures could be identified. A larger-bore suction catheter without side holes proved necessary to solve the problem. The case illustrates how a gradually forming blood clot can remain asymptomatic until reaching a size where it poses an airway threat and highlights the necessity for readily available larger-bore suction devices without side holes. We consider this as an important reminder of the unpredictable nature of blood clot formation and its management.


Assuntos
Trombose , Tonsilectomia , Humanos , Sucção , Tonsilectomia/efeitos adversos , Cateterismo , Trombose/cirurgia , Catéteres/efeitos adversos
20.
Sci Rep ; 14(1): 4298, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-38383707

RESUMO

The placement of a jejunostomy catheter during esophagectomy may cause postoperative bowel obstruction. The proximity of the jejunostomy site to the midline might be associated with bowel obstruction, and we have introduced laparoscopic jejunostomy (Lap-J) to reduce jejunostomy's left lateral gap. We evaluated 92 patients who underwent esophagectomy for esophageal cancer between February 2013 and August 2022 to clarify the benefits of Lap-J compared to other methods. The patients were classified into two groups according to the method of feeding catheter insertion: jejunostomy via small laparotomy (J group, n = 75), and laparoscopic jejunostomy (Lap-J group, n = 17). Surgery for bowel obstruction associated with the feeding jejunostomy catheter (BOFJ) was performed on 11 in the J group. Comparing the J and Lap-J groups, the distance between the jejunostomy and midline was significantly longer in the Lap-J group (50 mm vs. 102 mm; P < 0.001). Regarding surgery for BOFJ, the distance between the jejunostomy and midline was significantly shorter in the surgery group than in the non-surgery group (43 mm vs. 52 mm; P = 0.049). During esophagectomy, Lap-J can prevent BOFJ by placing the jejunostomy site at the left lateral position to the midline and reducing the left lateral gap of the jejunostomy.


Assuntos
Neoplasias Esofágicas , Obstrução Intestinal , Laparoscopia , Humanos , Jejunostomia/efeitos adversos , Jejunostomia/métodos , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Estudos Retrospectivos , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações , Laparoscopia/efeitos adversos , Obstrução Intestinal/etiologia , Catéteres/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA