Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.680
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Radiology ; 311(2): e233136, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742971

RESUMO

Background MR elastography (MRE) has been shown to have excellent performance for noninvasive liver fibrosis staging. However, there is limited knowledge regarding the precision and test-retest repeatability of stiffness measurement with MRE in the multicenter setting. Purpose To determine the precision and test-retest repeatability of stiffness measurement with MRE across multiple centers using the same phantoms. Materials and Methods In this study, three cylindrical phantoms made of polyvinyl chloride gel mimicking different degrees of liver stiffness in humans (phantoms 1-3: soft, medium, and hard stiffness, respectively) were evaluated. Between January 2021 and January 2022, phantoms were circulated between five different centers and scanned with 10 MRE-equipped clinical 1.5-T and 3-T systems from three major vendors, using two-dimensional (2D) gradient-recalled echo (GRE) imaging and/or 2D spin-echo (SE) echo-planar imaging (EPI). Similar MRE acquisition parameters, hardware, and reconstruction algorithms were used at each center. Mean stiffness was measured by a single observer for each phantom and acquisition on a single section. Stiffness measurement precision and same-session test-retest repeatability were assessed using the coefficient of variation (CV) and the repeatability coefficient (RC), respectively. Results The mean precision represented by the CV was 5.8% (95% CI: 3.8, 7.7) for all phantoms and both sequences combined. For all phantoms, 2D GRE achieved a CV of 4.5% (95% CI: 3.3, 5.7) whereas 2D SE EPI achieved a CV of 7.8% (95% CI: 3.1, 12.6). The mean RC of stiffness measurement was 5.8% (95% CI: 3.7, 7.8) for all phantoms and both sequences combined, 4.9% (95% CI: 2.7, 7.0) for 2D GRE, and 7.0% (95% CI: 2.9, 11.2) for 2D SE EPI (all phantoms). Conclusion MRE had excellent in vitro precision and same-session test-retest repeatability in the multicenter setting when similar imaging protocols, hardware, and reconstruction algorithms were used. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Tang in this issue.


Assuntos
Técnicas de Imagem por Elasticidade , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Reprodutibilidade dos Testes , Humanos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Cirrose Hepática/diagnóstico por imagem
3.
Clin Imaging ; 110: 110168, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38703476

RESUMO

BACKGROUND & AIM: Esophageal varices (EV) screening guidelines have evolved with improved risk stratification to avoid unnecessary esophagogastroduodenoscopy (EGD) in individuals with low bleeding risks. However, uncertainties persist in the recommendations for certain patient groups, particularly those with hepatocellular carcinoma (HCC) and/or receiving non-selective beta-blockers (NSBB) without prior endoscopy. This study assessed the efficacy of imaging in ruling out EVs and their high-risk features associated with bleeding in patients with cirrhosis and with HCC. We also evaluated the impact of NSBB on the detection of these characteristics. METHODS: A total of 119 patients undergoing EGD with CT and/or MRI within 90 days of the procedure were included. 87 patients had HCC. A new imaging grading system was developed utilizing the size of EVs and the extent of their protrusion into the esophagus lumen. The negative predictive value (NPV) of EVimaging(-) versus EVimaging (+) (grades 1-3) in ruling out the presence of EV and/or high-risk features by EGD was calculated. The predictive performance of imaging was determined by logistic regression. RESULTS: The NPV of imaging for detecting EV and high-risk features was 81 % and 92 %, respectively. Among HCC patients, the NPV for EV and high-risk features was 80 % and 64 %, respectively. Being on NSBB didn't statistically impact the imaging detection of EV. Imaging was a better predictor of high-risk EGD findings than Child-Turcotte-Pugh scores. CONCLUSIONS: Our results suggest that imaging can effectively rule out the presence of EV and high-risk features during EGD, even in patients with HCC and/or receiving NSBB.


Assuntos
Varizes Esofágicas e Gástricas , Hemorragia Gastrointestinal , Cirrose Hepática , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Varizes Esofágicas e Gástricas/diagnóstico por imagem , Varizes Esofágicas e Gástricas/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/complicações , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/complicações , Endoscopia do Sistema Digestório/métodos , Medição de Risco , Adulto , Valor Preditivo dos Testes
4.
Tomography ; 10(4): 471-479, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38668394

RESUMO

BACKGROUND: Refractory ascites affects the prognosis and quality of life in patients with liver cirrhosis. Peritoneovenous shunt (PVS) is a treatment procedure of palliative interventional radiology for refractory ascites. Although it is reportedly associated with serious complications (e.g., heart failure, thrombotic disease), the clinical course of PVS has not been thoroughly evaluated. OBJECTIVES: To evaluate the relationship between chronological course and complications after PVS for refractory ascites in liver cirrhosis patients. MATERIALS AND METHODS: This was a retrospective study of 14 patients with refractory ascites associated with decompensated cirrhosis who underwent PVS placement between June 2011 and June 2023. The clinical characteristics, changes in cardiothoracic ratio (CTR), and laboratory data (i.e., brain natriuretic peptide (BNP), D-dimer, platelet) were evaluated. Follow-up CT images in eight patients were also evaluated for ascites and complications. RESULTS: No serious complication associated with the procedure occurred in any case. Transient increases in BNP and D-dimer levels, decreased platelet counts, and the worsening of CTR were observed in the 2 days after PVS; however, they were improved in 7 days in all cases except one. In the follow-up CT, the amount of ascites decreased in all patients, but one patient with a continuous increase in D-dimer 2 and 7 days after PVS had thrombotic disease (renal and splenic infarction). The mean PVS patency was 345.4 days, and the median survival after PVS placement was 474.4 days. CONCLUSIONS: PVS placement for refractory ascites is a technically feasible palliative therapy. The combined evaluation of chronological changes in BNP, D-dimer, platelet count and CTR, and follow-up CT images may be useful for the early prediction of the efficacy and complications of PVS.


Assuntos
Ascite , Cirrose Hepática , Derivação Peritoneovenosa , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Ascite/etiologia , Idoso , Derivação Peritoneovenosa/métodos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Cuidados Paliativos/métodos , Adulto , Produtos de Degradação da Fibrina e do Fibrinogênio/análise
5.
BMC Med Imaging ; 24(1): 87, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609843

RESUMO

BACKGROUND: Fibrosis has important pathoetiological and prognostic roles in chronic liver disease. This study evaluates the role of radiomics in staging liver fibrosis. METHOD: After literature search in electronic databases (Embase, Ovid, Science Direct, Springer, and Web of Science), studies were selected by following precise eligibility criteria. The quality of included studies was assessed, and meta-analyses were performed to achieve pooled estimates of area under receiver-operator curve (AUROC), accuracy, sensitivity, and specificity of radiomics in staging liver fibrosis compared to histopathology. RESULTS: Fifteen studies (3718 patients; age 47 years [95% confidence interval (CI): 42, 53]; 69% [95% CI: 65, 73] males) were included. AUROC values of radiomics for detecting significant fibrosis (F2-4), advanced fibrosis (F3-4), and cirrhosis (F4) were 0.91 [95%CI: 0.89, 0.94], 0.92 [95%CI: 0.90, 0.95], and 0.94 [95%CI: 0.93, 0.96] in training cohorts and 0.89 [95%CI: 0.83, 0.91], 0.89 [95%CI: 0.83, 0.94], and 0.93 [95%CI: 0.91, 0.95] in validation cohorts, respectively. For diagnosing significant fibrosis, advanced fibrosis, and cirrhosis the sensitivity of radiomics was 84.0% [95%CI: 76.1, 91.9], 86.9% [95%CI: 76.8, 97.0], and 92.7% [95%CI: 89.7, 95.7] in training cohorts, and 75.6% [95%CI: 67.7, 83.5], 80.0% [95%CI: 70.7, 89.3], and 92.0% [95%CI: 87.8, 96.1] in validation cohorts, respectively. Respective specificity was 88.6% [95% CI: 83.0, 94.2], 88.4% [95% CI: 81.9, 94.8], and 91.1% [95% CI: 86.8, 95.5] in training cohorts, and 86.8% [95% CI: 83.3, 90.3], 94.0% [95% CI: 89.5, 98.4], and 88.3% [95% CI: 84.4, 92.2] in validation cohorts. Limitations included use of several methods for feature selection and classification, less availability of studies evaluating a particular radiological modality, lack of a direct comparison between radiology and radiomics, and lack of external validation. CONCLUSION: Although radiomics offers good diagnostic accuracy in detecting liver fibrosis, its role in clinical practice is not as clear at present due to comparability and validation constraints.


Assuntos
Radiologia , Radiômica , Masculino , Humanos , Pessoa de Meia-Idade , Cirrose Hepática/diagnóstico por imagem , Área Sob a Curva , Bases de Dados Factuais
6.
BMC Gastroenterol ; 24(1): 133, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609880

RESUMO

BACKGROUND: Preventing disease progression and viral suppression are the main goals of antiviral therapy in chronic hepatitis B (CHB). Liver stiffness measurement (LSM) by transient elastography is a reliable non-invasive method to assess liver fibrosis in patients with CHB. Our aim was to explore factors that may affect changes in LSMs during long term tenofovir (TDF) monotherapy in a well characterized cohort of patients with compensated CHB. METHODS: We analyzed serial LSMs in 103 adult patients with CHB who were on TDF monotherapy and had at least three LSMs over a period of 90 months. RESULTS: Twenty-five (24%) patients had advanced fibrosis at baseline. A significant decline in mean LSM between baseline and last visit (8.7 ± 6.2 kPa vs. 6.7 ± 3.3, p = 10- 3) was observed. Twenty-four (23%) patients had progression of liver fibrosis with mean increase in liver stiffness of 2.8 kPa (range: 0.2-10.2 kPa). Multivariate analysis showed that BMI ≥ 25 (OR, 0.014; 95% CI, 0.001-0.157; p = 0.001) and advanced fibrosis (OR, 5.169; 95% CI, 1.240-21.540; p = 0.024) were independently associated with a fibrosis regression of > 30% of liver stiffness compared to baseline value. CONCLUSIONS: In CHB patients TDF monotherapy resulted in liver fibrosis regression, especially in patients with advanced fibrosis. Despite the successful antiviral effect of TDF, 1 out of 4 patients had liver fibrosis progression. Obesity and advanced fibrosis at baseline were independently associated with significant liver fibrosis regression.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatite B Crônica , Adulto , Humanos , Hepatite B Crônica/complicações , Hepatite B Crônica/tratamento farmacológico , Estudos Prospectivos , Estudos Retrospectivos , Cirrose Hepática/diagnóstico por imagem , Tenofovir/uso terapêutico
7.
Hong Kong Med J ; 30(2): 110-119, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38651202

RESUMO

INTRODUCTION: Methotrexate (MTX) is effective for treating psoriasis and psoriatic arthritis, but its potential hepatoxicity remains a concern. Liver biopsy, the gold standard for detecting MTX-induced liver injury, is invasive and carries considerable risk. Transient elastography (TE) offers a non-invasive alternative for detecting advanced liver fibrosis. This study investigated the performance of TE in detecting MTX-induced liver fibrosis among Chinese psoriasis patients, compared with liver biopsy. METHODS: This study included adult patients with clinical psoriasis. Liver stiffness measurement using TE was performed in patients receiving MTX. Exclusion criteria were known liver cirrhosis, positive viral hepatitis carrier status, or conditions influencing TE performance. Liver biopsy was performed when liver stiffness was ≥7.1 kilopascals (kPa) or when the total cumulative dose (TCD) of MTX was ≥3.5 g. RESULTS: A total of 228 patients were screened; among 34 patients who met the inclusion criteria, nine (26.5%) had significant liver fibrosis (Roenigk grade ≥3a). The area under the receiver operating characteristic curve was 0.76 (95% confidence interval=0.59-0.93; P=0.021), indicating that TE had satisfactory performance in detecting liver fibrosis. A cut-off value of 7.1 kPa of liver stiffness yielded 100% sensitivity and 68% specificity. Liver fibrosis was not correlated with the TCD of MTX or the duration of MTX use; it was significantly correlated with obesity and diabetes status (body mass index ≥30 kg/m2, waist circumference ≥138 cm, and glycated haemoglobin level ≥7.8%). CONCLUSION: Transient elastography is reliable and superior to the TCD for detecting liver fibrosis in Chinese psoriasis patients receiving MTX. Liver biopsy should be reserved for high-risk patients or patients with liver stiffness ≥11.7 kPa on TE.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Metotrexato , Psoríase , Humanos , Técnicas de Imagem por Elasticidade/métodos , Metotrexato/efeitos adversos , Metotrexato/uso terapêutico , Metotrexato/administração & dosagem , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Psoríase/tratamento farmacológico , Psoríase/complicações , Psoríase/patologia , Feminino , Pessoa de Meia-Idade , Adulto , Fígado/patologia , Fígado/diagnóstico por imagem , Biópsia , Curva ROC , Fármacos Dermatológicos/uso terapêutico , Fármacos Dermatológicos/efeitos adversos , Fármacos Dermatológicos/administração & dosagem , Idoso , População do Leste Asiático
8.
Medicine (Baltimore) ; 103(17): e37949, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669359

RESUMO

Liver fibrosis is a critical factor in the advancement of nonalcoholic fatty liver disease towards cirrhosis. There is limited research exploring the association between obstructive sleep apnea (OSA) and liver fibrosis among community populations. The present study aimed to assess the association between sleep apnea (SA) and liver fibrosis based on the National Health and Nutrition Examination Survey (NHANES). Data were acquired from NHANES survey cycle 2017 to 2020. We assessed liver fibrosis by the median values of liver stiffness measurement (LSM). The diagnosis of SA was based on participants' response to sleep questionnaire. Univariate and multivariate logistic regression were used to validate the association of SA and liver fibrosis. A total of 7615 participants were included in this study. The LSM level of SA group was significantly higher than non-SA group. The proportion of liver fibrosis in SA group was markedly higher than that in non-SA group (14.0% vs 7.3%, P < .001). Univariate logistic analysis showed that SA was positively associated with liver fibrosis (OR = 2.068, 95%CI = 1.715-2.494, P < .001). Further multivariate logistic analysis revealed that SA was independently associated with increased risk of liver fibrosis after adjusting for confounding factors (OR = 1.277, 95%CI = 1.003-1.625, P = .048). The current study demonstrated an independent association between self-reported SA and increased risk of ultrasound-defined liver fibrosis in community-based sample.


Assuntos
Cirrose Hepática , Inquéritos Nutricionais , Ultrassonografia , Humanos , Masculino , Feminino , Cirrose Hepática/epidemiologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/complicações , Pessoa de Meia-Idade , Adulto , Síndromes da Apneia do Sono/epidemiologia , Fatores de Risco , Estudos Transversais , Idoso , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações
9.
Ultrason Imaging ; 46(3): 197-206, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38651542

RESUMO

This study addresses a crucial necessity in the field of noninvasive liver fibrosis diagnosis by introducing the concept of continuous shear wave elastography (C-SWE), utilizing an external vibration source and color Doppler imaging. However, an application of C-SWE to assess liver elasticity, a deep region within the human body, arises an issue of signal instability in the obtained data. To tackle this challenge, this work proposes a method involving the acquisition of multiple frames of datasets, which are subsequently compressed. Furthermore, the proposed frame-to-frame equalization method compensates discrepancies in the initial phase that might exist among multiple-frame datasets, thereby significantly enhancing signal stability. The experimental validation of this approach encompasses both phantom tests and in vivo experiments. In the phantom tests, the proposed technique is validated through a comparison with the established shear wave elastography (SWE) technique. The results demonstrate a remarkable agreement, with an error in shear wave velocity of less than 4.2%. Additionally, the efficacy of the proposed method is confirmed through in vivo tests. As a result, the stabilization of observed shear waves using the frame-to-frame equalization technique exhibits promising potential for accurately assessing human liver elasticity. These findings collectively underscore the viability of C-SWE as a potential diagnostic instrument for liver fibrosis.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática , Fígado , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Humanos , Fígado/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Reprodutibilidade dos Testes , Masculino , Adulto , Feminino
10.
World J Gastroenterol ; 30(12): 1663-1669, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38617743

RESUMO

Liver disease accounts for approximately 2 million deaths per year worldwide. All chronic liver diseases (CLDs), whether of toxic, genetic, autoimmune, or infectious origin, undergo typical histological changes in the structure of the tissue. These changes may include the accumulation of extracellular matrix material, fats, triglycerides, or tissue scarring. Noninvasive methods for diagnosing CLD, such as conventional B-mode ultrasound (US), play a significant role in diagnosis. Doppler US, when coupled with B-mode US, can be helpful in evaluating the hemodynamics of hepatic vessels and detecting US findings associated with hepatic decompensation. US elastography can assess liver stiffness, serving as a surrogate marker for liver fibrosis. It is important to note that interpreting these values should not rely solely on a histological classification. Contrast-enhanced US (CEUS) provides valuable information on tissue perfusion and enables excellent differentiation between benign and malignant focal liver lesions. Clinical evaluation, the etiology of liver disease, and the patient current comorbidities all influence the interpretation of liver stiffness measurements. These measurements are most clinically relevant when interpreted as a probability of compensated advanced CLD. B-mode US offers a subjective estimation of fatty infiltration and has limited sensitivity for mild steatosis. The controlled attenuation parameter requires a dedicated device, and cutoff values are not clearly defined. Quan-titative US parameters for liver fat estimation include the attenuation coefficient, backscatter coefficient, and speed of sound. These parameters offer the advantage of providing fat quantification alongside B-mode evaluation and other US parameters. Multiparametric US (MPUS) of the liver introduces a new concept for complete noninvasive diagnosis. It encourages examiners to utilize the latest features of an US machine, including conventional B-mode, liver stiffness evaluation, fat quantification, dispersion imaging, Doppler US, and CEUS for focal liver lesion characterization. This comprehensive approach allows for diagnosis in a single examination, providing clinicians worldwide with a broader perspective and becoming a cornerstone in their diagnostic arsenal. MPUS, in the hands of skilled clinicians, becomes an invaluable predictive tool for diagnosing, staging, and monitoring CLD.


Assuntos
Fígado Gorduroso , Hepatopatias , Humanos , Hepatopatias/diagnóstico por imagem , Ultrassonografia , Cirrose Hepática/diagnóstico por imagem
11.
BMC Med Imaging ; 24(1): 90, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627672

RESUMO

BACKGROUND: Wilson's disease (WD) often leads to liver fibrosis and cirrhosis, and early diagnosis of WD cirrhosis is essential. Currently, there are few non-invasive prediction models for WD cirrhosis. The purpose of this study is to non-invasively predict the occurrence risk of compensated WD cirrhosis based on ultrasound imaging features and clinical characteristics. METHODS: A retrospective analysis of the clinical characteristics and ultrasound examination data of 102 WD patients from November 2018 to November 2020 was conducted. According to the staging system for WD liver involvement, the patients were divided into a cirrhosis group (n = 43) and a non-cirrhosis group (n = 59). Multivariable logistic regression analysis was used to identify independent influencing factors for WD cirrhosis. A nomogram for predicting WD cirrhosis was constructed using R analysis software, and validation of the model's discrimination, calibration, and clinical applicability was completed. Due to the low incidence of WD and the small sample size, bootstrap internal sampling with 500 iterations was adopted for validation to prevent overfitting of the model. RESULTS: Acoustic Radiation Force Impulse (ARFI), portal vein diameter (PVD), and serum albumin (ALB) are independent factors affecting WD cirrhosis. A nomogram for WD cirrhosis was constructed based on these factors. The area under the ROC curve (AUC) of the model's predictive ability is 0.927 (95% CI: 0.88-0.978). As demonstrated by 500 Bootstrap internal sampling validations, the model has high discrimination and calibration. Clinical decision curve analysis shows that the model has high clinical practical value. ROC curve analysis of the model's rationality indicates that the model's AUC is greater than the AUC of using ALB, ARFI, and PVD alone. CONCLUSION: The nomogram model constructed based on ARFI, PVD, and ALB can serve as a non-invasive tool to effectively predict the risk of developing WD cirrhosis.


Assuntos
Degeneração Hepatolenticular , Humanos , Degeneração Hepatolenticular/diagnóstico por imagem , Degeneração Hepatolenticular/complicações , Nomogramas , Estudos Retrospectivos , Cirrose Hepática/diagnóstico por imagem , Curva ROC
13.
World J Gastroenterol ; 30(15): 2128-2142, 2024 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-38681988

RESUMO

BACKGROUND: The prognosis for hepatocellular carcinoma (HCC) in the presence of cirrhosis is unfavourable, primarily attributable to the high incidence of recurrence. AIM: To develop a machine learning model for predicting early recurrence (ER) of post-hepatectomy HCC in patients with cirrhosis and to stratify patients' overall survival (OS) based on the predicted risk of recurrence. METHODS: In this retrospective study, 214 HCC patients with cirrhosis who underwent curative hepatectomy were examined. Radiomics feature selection was conducted using the least absolute shrinkage and selection operator and recursive feature elimination methods. Clinical-radiologic features were selected through univariate and multivariate logistic regression analyses. Five machine learning methods were used for model comparison, aiming to identify the optimal model. The model's performance was evaluated using the receiver operating characteristic curve [area under the curve (AUC)], calibration, and decision curve analysis. Additionally, the Kaplan-Meier (K-M) curve was used to evaluate the stratification effect of the model on patient OS. RESULTS: Within this study, the most effective predictive performance for ER of post-hepatectomy HCC in the background of cirrhosis was demonstrated by a model that integrated radiomics features and clinical-radiologic features. In the training cohort, this model attained an AUC of 0.844, while in the validation cohort, it achieved a value of 0.790. The K-M curves illustrated that the combined model not only facilitated risk stratification but also exhibited significant discriminatory ability concerning patients' OS. CONCLUSION: The combined model, integrating both radiomics and clinical-radiologic characteristics, exhibited excellent performance in HCC with cirrhosis. The K-M curves assessing OS revealed statistically significant differences.


Assuntos
Carcinoma Hepatocelular , Hepatectomia , Cirrose Hepática , Neoplasias Hepáticas , Aprendizado de Máquina , Recidiva Local de Neoplasia , Tomografia Computadorizada por Raios X , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Feminino , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/cirurgia , Estudos Retrospectivos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Idoso , Tomografia Computadorizada por Raios X/métodos , Prognóstico , Valor Preditivo dos Testes , Curva ROC , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Estimativa de Kaplan-Meier , Adulto , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Fatores de Risco , Radiômica
14.
Radiology ; 311(1): e231461, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38652028

RESUMO

Background Noninvasive tests can be used to screen patients with chronic liver disease for advanced liver fibrosis; however, the use of single tests may not be adequate. Purpose To construct sequential clinical algorithms that include a US deep learning (DL) model and compare their ability to predict advanced liver fibrosis with that of other noninvasive tests. Materials and Methods This retrospective study included adult patients with a history of chronic liver disease or unexplained abnormal liver function test results who underwent B-mode US of the liver between January 2014 and September 2022 at three health care facilities. A US-based DL network (FIB-Net) was trained on US images to predict whether the shear-wave elastography (SWE) value was 8.7 kPa or higher, indicative of advanced fibrosis. In the internal and external test sets, a two-step algorithm (Two-step#1) using the Fibrosis-4 Index (FIB-4) followed by FIB-Net and a three-step algorithm (Three-step#1) using FIB-4 followed by FIB-Net and SWE were used to simulate screening scenarios where liver stiffness measurements were not or were available, respectively. Measures of diagnostic accuracy were calculated using liver biopsy as the reference standard and compared between FIB-4, SWE, FIB-Net, and European Association for the Study of the Liver guidelines (ie, FIB-4 followed by SWE), along with sequential algorithms. Results The training, validation, and test data sets included 3067 (median age, 42 years [IQR, 33-53 years]; 2083 male), 1599 (median age, 41 years [IQR, 33-51 years]; 1124 male), and 1228 (median age, 44 years [IQR, 33-55 years]; 741 male) patients, respectively. FIB-Net obtained a noninferior specificity with a margin of 5% (P < .001) compared with SWE (80% vs 82%). The Two-step#1 algorithm showed higher specificity and positive predictive value (PPV) than FIB-4 (specificity, 79% vs 57%; PPV, 44% vs 32%) while reducing unnecessary referrals by 42%. The Three-step#1 algorithm had higher specificity and PPV compared with European Association for the Study of the Liver guidelines (specificity, 94% vs 88%; PPV, 73% vs 64%) while reducing unnecessary referrals by 35%. Conclusion A sequential algorithm combining FIB-4 and a US DL model showed higher diagnostic accuracy and improved referral management for all-cause advanced liver fibrosis compared with FIB-4 or the DL model alone. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Ghosh in this issue.


Assuntos
Algoritmos , Técnicas de Imagem por Elasticidade , Cirrose Hepática , Humanos , Masculino , Cirrose Hepática/diagnóstico por imagem , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Técnicas de Imagem por Elasticidade/métodos , Adulto , Aprendizado Profundo , Fígado/diagnóstico por imagem , Fígado/patologia , Idoso , Ultrassonografia/métodos
15.
Medicine (Baltimore) ; 103(17): e37899, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669377

RESUMO

To investigate the clinical value of contrast-enhanced ultrasound in the prediction of hepatic encephalopathy (HE) in patients with hepatitis B cirrhosis after intrahepatic portal-systemic shunt via jugular vein. In this retrospective study, we collected data from 75 patients with hepatitis B, cirrhosis, and portal hypertension who underwent jugular intrahepatic portosystemic shunt from February 2019 to February 2022. The diagnostic instrument used was the TOSHIBA Aplio500 color Doppler ultrasound with contrast-enhanced ultrasound capabilities. The trial group comprised 20 patients with HE within 3 months postsurgery, while the control group (CG) included 55 patients without HE within the same postoperative period. All patients underwent various examinations before and within 48 hours after surgery, including observation of liver and spleen size and stent position, as well as assessment of blood flow direction in portal and hepatic veins. Subsequently, contrast-enhanced ultrasound was employed to examine and observe perfusion changes of contrast agents in hepatic veins, hepatic arteries, and portal veins (PV). Changes in PV pressure gradient, intrahepatic, and stent blood flow perfusion (BFP) were explored in both postoperative trials and CGs. The trial group exhibited higher BFP volume, PV pressure gradient difference, and percentage decrease compared to the CG. A weak positive correlation was observed between blood flow within the liver stent and PV pressure gradient difference, as well as the percentage decrease in PV pressure gradient. The correlation coefficient between blood flowing perfusion volume within the stent and the difference in PV pressure gradient was R = 0.415 (P = .000). The correlating coefficient between BFP amount within the stent and the percentage decrease in PV pressure gradient was R = 0.261 (P = .027). The area under the receiver operating characteristic curve for stent perfusion volume, difference in PV pressure gradient, and percentage decrease in PV pressure gradient was 0.691, 0.759, and 0.742, respectively. An increase in PV pressure gradient accelerates blood flow within the stent, predisposing to HE. Changes in hepatic BFP following transjugular intrahepatic portosystemic shunt can effectively predict the occurrence of HE, demonstrating significant clinical relevance.


Assuntos
Meios de Contraste , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Masculino , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Hipertensão Portal/cirurgia , Hipertensão Portal/fisiopatologia , Hipertensão Portal/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/cirurgia , Ultrassonografia Doppler em Cores/métodos , Adulto , Cirrose Hepática/cirurgia , Cirrose Hepática/fisiopatologia , Cirrose Hepática/diagnóstico por imagem , Circulação Hepática/fisiologia , Idoso , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Relevância Clínica
16.
World J Gastroenterol ; 30(10): 1450-1460, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38596502

RESUMO

BACKGROUND: Direct-acting antiviral agents (DAAs) are highly effective treatment for chronic hepatitis C (CHC) with a significant rate of sustained virologic response (SVR). The achievement of SVR is crucial to prevent additional liver damage and slow down fibrosis progression. The assessment of fibrosis degree can be performed with transient elastography, magnetic resonance elastography or shear-wave elastography (SWE). Liver elastography could function as a predictor for hepatocellular carcinoma (HCC) in CHC patients treated with DAAs. AIM: To explore the predictive value of SWE for HCC development after complete clearance of hepatitis C virus (HCV). METHODS: A comprehensive literature search of clinical studies was performed to identify the ability of SWE to predict HCC occurrence after HCV clearance. In accordance with the study protocol, a qualitative and quantitative analysis of the evidence was planned. RESULTS: At baseline and after 12 wk of follow-up, a trend was shown towards greater liver stiffness (LS) in those who go on to develop HCC compared to those who do not [baseline LS standardized mean difference (SMD): 1.15, 95% confidence interval (95%CI): 020-2.50; LS SMD after 12 wk: 0.83, 95%CI: 0.33-1.98]. The absence of a statistically significant difference between the mean LS in those who developed HCC or not may be related to the inability to correct for confounding factors and the absence of raw source data. There was a statistically significant LS SMD at 24 wk of follow-up between patients who developed HCC vs not (0.64; 95%CI: 0.04-1.24). CONCLUSION: SWE could be a promising tool for prediction of HCC occurrence in patients treated with DAAs. Further studies with larger cohorts and standardized timing of elastographic evaluation are needed to confirm these data.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Hepatite C Crônica , Hepatite C , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/tratamento farmacológico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/tratamento farmacológico , Hepacivirus , Técnicas de Imagem por Elasticidade/métodos , Antivirais/uso terapêutico , Hepatite C Crônica/complicações , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/tratamento farmacológico , Resposta Viral Sustentada , Fibrose , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/tratamento farmacológico , Hepatite C/tratamento farmacológico
17.
Radiology ; 311(1): e232188, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38591973

RESUMO

Background The Society of Radiologists in Ultrasound (SRU) has proposed thresholds for acoustic radiation force impulse techniques to diagnose compensated advanced chronic liver disease (cACLD). However, the diagnostic performance of these thresholds has not been extensively validated. Purpose To validate the SRU thresholds in patients with chronic liver disease who underwent supersonic shear imaging and, if suboptimal diagnostic performance is observed, to identify optimal values for diagnosing cACLD. Materials and Methods This retrospective single-center study included high-risk patients with chronic liver disease who had liver stiffness (LS) measurements and had undergone endoscopy or liver biopsy between January 2018 and December 2021. Patients were randomly allocated to test and validation sets. cACLD was defined as varices at endoscopy and/or severe fibrosis or cirrhosis at liver biopsy. The diagnostic performance of the SRU guidelines was evaluated, and optimal threshold values were identified using receiver operating characteristic (ROC) curve analysis. Results A total of 1180 patients (median age, 57 years [IQR, 50-64 years]; 761 men), of whom 544 (46%) had cACLD, were included. With the SRU recommended thresholds of less than 9 kPa and greater than 13 kPa in the test set (n = 786), the sensitivity and specificity for ruling out and ruling in cACLD were 81% (303 of 374 patients; 95% CI: 77, 85) and 92% (380 of 412 patients; 95% CI: 89, 94), respectively. In ROC curve analysis, the identified optimal threshold values were less than 7 kPa and greater than 12 kPa, showing 91% sensitivity (340 of 374 patients; 95% CI: 88, 93) for ruling out cACLD and 91% specificity (373 of 412 patients; 95% CI: 87, 93) for ruling in cACLD, respectively. In the validation set (n = 394), the optimal thresholds showed 91% sensitivity (155 of 170 patients; 95% CI: 86, 95) and 92% specificity (206 of 224 patients; 95% CI: 88, 95). Conclusion Compared with the SRU guidelines, the dual LS threshold values of less than 7 kPa and greater than 12 kPa were better for diagnosing cACLD. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Barr in this issue.


Assuntos
Diagnóstico por Imagem , Hepatopatias , Masculino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Hepatopatias/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Biópsia
18.
World J Gastroenterol ; 30(9): 1164-1176, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38577177

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) has been developed to stage liver fibrosis. However, its diagnostic performance is inconsistent among studies. Therefore, it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort. AIM: To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances. METHODS: This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants. All participants underwent multi-b value DWI. The main DWI-derived parameters included Mono-apparent diffusion coefficient (ADC) from mono-exponential DWI, intravoxel incoherent motion model-derived true diffusion coefficient (IVIM-D), diffusion kurtosis imaging-derived apparent diffusivity (DKI-MD), stretched exponential model-derived distributed diffusion coefficient (SEM-DDC), fractional order calculus (FROC) model-derived diffusion coefficient (FROC-D) and FROC model-derived microstructural quantity (FROC-µ), and continuous-time random-walk (CTRW) model-derived anomalous diffusion coefficient (CTRW-D) and CTRW model-derived temporal diffusion heterogeneity index (CTRW-α). The correlations between DWI-derived parameters and fibrosis stages and the parameters' diagnostic efficacy in detecting significant fibrosis (SF) were assessed and compared. RESULTS: CTRW-D (r = -0.356), CTRW-α (r = -0.297), DKI-MD (r = -0.297), FROC-D (r = -0.350), FROC-µ (r = -0.321), IVIM-D (r = -0.251), Mono-ADC (r = -0.362), and SEM-DDC (r = -0.263) were significantly correlated with fibrosis stages. The areas under the ROC curves (AUCs) of the combined index of the six models for distinguishing SF (0.697-0.747) were higher than each of the parameters alone (0.524-0.719). The DWI models' ability to detect SF was similar. The combined index of CTRW model parameters had the highest AUC (0.747). CONCLUSION: The DWI models were similarly valuable in distinguishing SF in patients with liver disease. The combined index of CTRW parameters had the highest AUC.


Assuntos
Imagem de Difusão por Ressonância Magnética , Hepatopatias , Humanos , Estudos Prospectivos , Imagem de Difusão por Ressonância Magnética/métodos , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imagem de Tensor de Difusão/métodos
19.
Sci Rep ; 14(1): 6943, 2024 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-38521854

RESUMO

Limited population-based studies discuss the association between fat mass index (FMI) and the risk of liver diseases. This investigation utilized data from the National Health and Nutrition Examination Survey (NHANES) to examine the linkage between the FMI and liver conditions, specifically steatosis and fibrosis. The study leveraged data from NHANES's 2017-2018 cross-sectional study, employing an oversampling technique to deal with sample imbalance. Hepatic steatosis and fibrosis were identified by vibration-controlled transient elastography. Receiver operating curve was used to assess the relationship of anthropometric indicators, e.g., the FMI, body mass index (BMI), weight-adjusted-waist index (WWI), percentage of body fat (BF%), waist-to-hip ratio (WHR), and appendicular skeletal muscle index (ASMI), with hepatic steatosis and fibrosis. In this study, which included 2260 participants, multivariate logistic regression models, stratified analyses, restricted cubic spline (RCS), and sharp regression discontinuity analyses were utilized. The results indicated that the WHR and the FMI achieved the highest area under the curve for identifying hepatic steatosis and fibrosis, respectively (0.720 and 0.726). Notably, the FMI presented the highest adjusted odds ratio for both hepatic steatosis (6.40 [4.91-8.38], p = 2.34e-42) and fibrosis (6.06 [5.00, 7.37], p = 5.88e-74). Additionally, potential interaction effects were observed between the FMI and variables such as the family income-to-poverty ratio, smoking status, and hypertension, all of which correlated with the presence of liver fibrosis (p for interaction < 0.05). The RCS models further confirmed a significant positive correlation of the FMI with the controlled attenuation parameter and liver stiffness measurements. Overall, the findings underscore the strong link between the FMI and liver conditions, proposing the FMI as a potential straightforward marker for identifying liver diseases.


Assuntos
Fígado Gorduroso , Hepatopatia Gordurosa não Alcoólica , Humanos , Inquéritos Nutricionais , Estudos Transversais , Índice de Massa Corporal , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/epidemiologia
20.
PLoS Negl Trop Dis ; 18(3): e0012033, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38507368

RESUMO

BACKGROUND: Abdominal ultrasound imaging is an important method for hepatic schistosomiasis diagnosis and staging. Several ultrasound staging systems have been proposed, each attempting to standardise schistosomal periportal fibrosis (PPF) diagnosis. This review aims to establish the role of ultrasound in the diagnosis and staging of schistosomal PPF, and to map the evolution of ultrasound staging systems over time, focusing on internal validation and external reproducibility. METHODS: A systematic search was undertaken on 21st December 2022 considering the following databases: PubMed/MEDLINE (1946-present), Embase (1974-present), Global Health (1973-present), Global Index Medicus (1901-present), and Web of Science Core Collection-Science Citation Index Expanded (1900-present) and the Cochrane Central Register of Controlled Trials (1996-present). Case reports, systematic reviews and meta-analyses, and studies exclusively using transient or shear-wave elastography were excluded. Variables extracted included study design, study population, schistosomal PPF characteristics, and diagnostic methods. The PRISMA-ScR (2018) guidelines were followed to inform the structure of the scoping analysis. RESULTS: The initial search yielded 573 unique articles, of which 168 were removed after screening titles and abstracts, 43 were not retrieved due to full texts not being available online or through inter-library loans, and 170 were excluded during full text review. There were 192 remaining studies eligible for extraction. Of the extracted studies, 61.8% (76/123) of studies that reported study year were conducted after the year 2000. Over half of all extracted studies (59.4%; 114/192) were conducted in Brazil (26.0%; 50/192), China (18.8%; 36/192) or Egypt (14.6%; 28/192). For the species of schistosome considered, 77.6% (149/192) of studies considered S. mansoni and 21.4% (41/192) of studies considered S. japonicum. The ultrasound staging systems used took on three forms: measurement-based, feature-based and image pattern-based. The Niamey protocol, a measurement and image pattern-based system, was the most used among the staging systems (32.8%; 63/192), despite being the most recently proposed in 1996. The second most used was the Cairo protocol (20.8%; 40/192). Of the studies using the Niamey protocol, 77.8% (49/63) only used the image patterns element. Where ultrasound technology was specified, studies after 2000 were more likely to use convex transducers (43.4%; 33/76) than studies conducted before 2000 (32.7%; 16/49). Reporting on ultrasound-based hepatic diagnoses and their association with clinical severity was poor. Just over half of studies (56.2%; 108/192) reported the personnel acquiring the ultrasound images. A small number (9.4%; 18/192) of studies detailed their methods of image quality assurance, and 13.0% (25/192) referenced, discussed or quantified the inter- or intra-observer variation of the staging system that was used. CONCLUSIONS: The exclusive use of the image patterns in many studies despite lack of specific acquisition guidance, the increasing number of studies over time that conduct ultrasound staging of schistosomal PPF, and the advances in ultrasound technology used since 2000 all indicate a need to consider an update to the Niamey protocol. The protocol update should simplify and prioritise what is to be assessed, advise on who is to conduct the ultrasound examination, and procedures for improved standardisation and external reproducibility.


Assuntos
Sistemas Automatizados de Assistência Junto ao Leito , Esquistossomose , Humanos , Reprodutibilidade dos Testes , Cirrose Hepática/diagnóstico por imagem , Ultrassonografia , Esquistossomose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA