Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Se Pu ; 42(5): 474-480, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736391

RESUMO

A method was established for the simultaneous detection of 12 prohibited veterinary drugs, including ß2-receptor agonists, nitrofuran metabolites, nitroimidazoles, chlorpromazine, and chloramphenicol, in pig urine. The sample was pretreated by enzymolysis, acid hydrolysis/derivatization, and liquid-liquid extraction combined with solid-phase extraction. Detection was performed using ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Ammonium acetate solution (0.2 mol/L, 4.5 mL) and ß-glucuronidase/aryl sulfatase (40 µL) were added to the sample, which was subsequently enzymolized at 37 ℃ for 2 h. Then, 1.5 mL of 1.0 mol/L hydrochloric acid solution and 100 µL of 0.1 mol/L o-nitrobenzaldehyde solution were added to the sample. The mixture was incubated at 37 ℃ for 16 h, and the analytes were extracted with 8 mL of ethyl acetate by liquid-liquid extraction. The lower aqueous phase obtained after extraction was extracted and purified using a mixed cation-exchange solid-phase extraction column. The extracts were combined, the extraction solution was blow-dried with nitrogen, and the residue was redissolved for determination. The samples were analyzed under multiple-reaction monitoring mode with both positive and negative electrospray ionization, and quantified using an isotope internal standard method. The correlation coefficients (r) of the 12 compounds were >0.99. The limits of detection (LODs) and quantification (LOQs) of chloramphenicol were 0.05 and 0.1 µg/L, respectively, and the LODs and LOQs of the other compounds were 0.25 and 0.5 µg/L, respectively. The mean recoveries and RSDs at 1, 2, and 10 times the LOQ were 83.6%-115.3% and 2.20%-12.34%, respectively. The proposed method has the advantages of high sensitivity, good stability, and accurate quantification; thus, it is suitable for the simultaneous determination of the 12 prohibited veterinary drug residues in pig urine.


Assuntos
Resíduos de Drogas , Espectrometria de Massas em Tandem , Drogas Veterinárias , Animais , Espectrometria de Massas em Tandem/métodos , Suínos , Cromatografia Líquida de Alta Pressão/métodos , Drogas Veterinárias/urina , Drogas Veterinárias/análise , Resíduos de Drogas/análise , Cloranfenicol/urina , Cloranfenicol/análise
2.
Anal Chim Acta ; 1306: 342598, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692791

RESUMO

BACKGROUND: Carbon-based nanozymes have recently received enormous concern, however, there is still a huge challenge for inexpensive and large-scale synthesis of magnetic carbon-based "Two-in-One" mimics with both peroxidase (POD)-like and laccase-like activities, especially their potential applications in multi-mode sensing of antibiotics and neurotransmitters in biofluids. Although some progresses have been made in this field, the feasibility of biomass-derived carbon materials with both POD-like and laccase-like activities by polyatomic doping strategy is still unclear. In addition, multi-mode sensing platform can provide a more reliable result because of the self-validation, self-correction and mutual agreement. Nevertheless, the use of magnetic carbon-based nanozyme sensors for the multi-mode detection of antibiotics and neurotransmitters have not been investigated. RESULTS: We herein report a shrimp shell-derived N, O-codoped porous carbon confined magnetic CuFe2O4 nanosphere with outstanding laccase-like and POD-like activities for triple-mode sensing of antibiotic d-penicillamine (D-PA) and chloramphenicol (CPL), as well as colorimetric detection of neurotransmitters in biofluids. The magnetic CuFe2O4/N, O-codoped porous carbon (MCNPC) armored mimetics was successfully fabricated using a combined in-situ coordination and high-temperature crystallization method. The synthesized MCNPC composite with superior POD-like activity can be used for colorimetric/temperature/smartphone-based triple-mode detection of D-PA and CPL in goat serum. Importantly, the MCNPC nanozyme can also be used for colorimetric analysis of dopamine and epinephrine in human urine. SIGNIFICANCE: This work not only offered a novel strategy to large-scale, cheap synthesize magnetic carbon-based "Two-in-One" armored mimetics, but also established the highly sensitive and selective platforms for triple-mode monitoring D-PA and CPL, as well as colorimetric analysis of neurotransmitters in biofluids without any tanglesome sample pretreatment.


Assuntos
Antibacterianos , Carbono , Cobre , Neurotransmissores , Carbono/química , Antibacterianos/análise , Antibacterianos/urina , Antibacterianos/sangue , Neurotransmissores/urina , Neurotransmissores/análise , Neurotransmissores/sangue , Porosidade , Cobre/química , Humanos , Nanosferas/química , Colorimetria/métodos , Compostos Férricos/química , Materiais Biomiméticos/química , Animais , Técnicas Biossensoriais/métodos , Cloranfenicol/análise , Cloranfenicol/urina , Limite de Detecção
3.
Ecotoxicol Environ Saf ; 204: 111066, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32781344

RESUMO

In this study, an iron-doped metal-organic framework (MOF) Fe/ZIF-8 was synthesized from ZIF-8 at room temperature. Direct carbonization of Fe/ZIF-8 under a nitrogen atmosphere produced nanoporous nitrogen doped carbon nanoparticles decorated with Fe component (Fe/NC). The Fe/NC exhibited a large surface area (1221.185 m2 g-1) and narrow pore-size distribution (3-5 nm). The nanoporous Fe/NC components along with Nafion were used to modify a glassy carbon electrode for the electrochemical determination of chloramphenicol and metronidazole via linear sweep voltammetry. Under optimal conditions, the reduction peak currents (observed at -0.237 V and -0.071 V vs. Ag/AgCl) of these analytes increased linearly with increasing chloramphenicol and metronidazole concentrations in the range of 0.1-100 µM and 0.5-30 µM, with the detection limits estimated to be 31 nM and 165 nM, respectively. This result was attributed to the large surface area, porous structure, high nitrogen content, and as well as the electrocatalytic effect of Fe atoms embeded in the carbon support. The proposed sensor was used for chloramphenicol and metronidazole analysis in samples, providing satisfactory results.


Assuntos
Carbono/química , Cloranfenicol/análise , Técnicas Eletroquímicas/métodos , Ferro/química , Estruturas Metalorgânicas/química , Metronidazol/análise , Nitrogênio/química , Animais , Cloranfenicol/urina , Eletrodos , Humanos , Limite de Detecção , Metronidazol/urina , Leite/química , Nanoporos , Soluções Oftálmicas/química , Porosidade , Comprimidos/química
4.
Mikrochim Acta ; 187(6): 319, 2020 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-32394282

RESUMO

A sensitive and selective method for the determination of the antibiotic chloramphenicol (CAP) is described, which is based on double signal amplification and GO as an efficient fluorescence quencher. The nucleic acid probe is composed of three well-defined regions, viz. the signal probe I, the signal probe II, and the capture probe. The capture probe will bind to CAP specifically and the signal probes produce a significant fluorescence signal. One end of the signal probes is labeled with the fluorophore 6-carboxyfluorescein (FAM). The labeled probes can be adsorbed on graphene oxide (GO) via π-stacking interactions, upon which the green fluorescence of FAM (measured at excitation/emission wavelengths of 490/514 nm) is quenched. On addition of CAP, the aptamer/CAP complexes are formed, and this leads to the restoration of fluorescence due to the removal of the probes from GO. The double signal probes, together with GO as quencher, improve the fluorescence signal significantly and lower the detection limit. Under optimized conditions, the assay works in the 20- to 200-ppb CAP concentration range and has a 0.3-ppb detection limit. It is also successfully applied to the determination of CAP in spiked swine urine samples. The recoveries from spiked swine urine samples are between 97.73 and 108.56%, and the repeatability (expressed as the RSD) is between 4.66 and 8.90%. Graphical abstract The constructed DNA probes form a stable structure and bind to chloramphenicol specifically. One end of signal probes was labeled with the fluorophore 6-carboxyfluorescein (FAM). The detection sensitivity of chloramphenicol was significantly enhanced by using double signal amplification, which was superior to the traditional methods. The quantities of CAP can be achieved by fluorescence increment.


Assuntos
Antibacterianos/urina , Cloranfenicol/urina , Grafite/química , Animais , Antibacterianos/química , Aptâmeros de Nucleotídeos/química , Sequência de Bases , Cloranfenicol/química , Sondas de DNA/química , Fluoresceínas/química , Corantes Fluorescentes/química , Ácidos Nucleicos Imobilizados/química , Limite de Detecção , Espectrometria de Fluorescência/métodos , Suínos
5.
Artigo em Inglês | MEDLINE | ID: mdl-32334391

RESUMO

A rapid procedure for the determination of amphenicol antibiotics in human urine by liquid chromatography with quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) is proposed. The presence of thiamphenicol (TAP), florfenicol (FF) and chloramphenicol (CAP) in the human body can be attributed to their administration to treat certain diseases or by eating food of animal origin. The TAP, FF and CAP excreted in urine is mainly in the form of glucuronide conjugates, although their free forms may also be excreted to a lesser extent. In the procedure described, the enzymatic hydrolysis of amphenicol glucuronide forms in urine was carried out using ß-glucuronidase and sulfatase at pH 5 (37 °C, overnight) in order to discriminate the free and conjugated forms. Then, amphenicol antibiotics were submitted to dispersive liquid-liquid microextraction (DLLME) for preconcentration. All the parameters affecting DLLME efficiency were optimized, and the following conditions were selected: 0.9 g NaCl in 10 mL of urine, to which 1.2 mL methanol (as dispersant solvent) and 1 mL of 4-methyl-2-pentanone (as extractant solvent) were added. The absence of a matrix effect allowed quantification of the samples against aqueous standards. Detection limits were 29, 6 and 3 pg mL-1 for TAP, FF and CAP, respectively. Relative standard deviations were calculated to evaluate the intra- and inter-day precision and values lower than 10% were obtained in all cases. The trueness of the method was tested through recovery studies, obtaining satisfactory values (83-104%). Ten urine samples obtained from volunteers were analysed and all of them were free of the studied antibiotics.


Assuntos
Antibacterianos/urina , Cloranfenicol/urina , Glucuronídeos/urina , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão , Glucuronidase/metabolismo , Humanos , Hidrólise , Limite de Detecção , Microextração em Fase Líquida , Metabolômica , Metanol/química , Metil n-Butil Cetona/química , Padrões de Referência , Solventes/química , Sulfatases/metabolismo , Tianfenicol/análogos & derivados , Tianfenicol/urina
6.
Biosens Bioelectron ; 146: 111756, 2019 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-31605990

RESUMO

Nanozymes have gained increasing attention in the field of biosensing. Rationally designed nanozymes with excellent catalytic activity are accessible to substitute natural enzymes. Herein, a novel self-powered photoelectrochemical (PEC) aptasensor was constructed for ultrasensitive detection of chloramphenicol (CAP) based on ultrathin PtNi nanowires (NWs) as nanozyme and benzene-ring doped g-C3N4 (BR-CN) as the photoactive material. The prepared 1-nm-thick PtNi nanozyme acted as a peroxidase, possessing higher catalytic activity than natural horseradish peroxidase (HRP) and other Pt-based mimic enzymes. Through the biotin-streptavidin specific interaction, streptavidin modified PtNi nanozyme was introduced into the dual-stranded DNA (dsDNA) formed by complementary DNA and biotinylated CAP aptamer. The PtNi nanozyme catalyzed 4-chloro-1-naphthol (4-CN) oxidation to generate insoluble precipitation on the electrode surface, resulting in an obvious photocurrent reduction. In the presence of CAP, the CAP aptamer was released from the electrode due to strong affinity with CAP, causing the decrease of catalytic precipitation and consequently the generation of a high photocurrent signal. On the basis of PtNi nanozyme signal amplification, the developed self-powered PEC aptasensor showed a wide linear range of 0.1 pM-100 nM with an ultralow detection limit of 26 fM for the determination of CAP. This work provides a feasible strategy for the design of high-activity nanozyme and self-powered PEC biosensor to achieve the ultrasensitive detection of target analyte.


Assuntos
Antibacterianos/análise , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/instrumentação , Cloranfenicol/análise , Nanofios/química , Animais , Antibacterianos/urina , Benzeno/química , Cloranfenicol/urina , Técnicas Eletroquímicas/instrumentação , Desenho de Equipamento , Limite de Detecção , Leite/química , Níquel/química , Platina/química , Rios/química , Suínos
7.
Anal Bioanal Chem ; 410(16): 3871-3883, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29671029

RESUMO

Bisphenol analogues, amphenicol antibiotics, and phthalate have widely aroused public concerns due to their adverse effects on human health. In this study, a rapid and sensitive method for determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in the urine based on ultra-high-performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry was developed and validated. The sample pretreatment condition on the base of mixed-mode anion-exchange (Oasis MAX) SPE was optimized to separate bisphenol analogues and amphenicol antibiotics from phthalate metabolites: the former were detected with a mobile phase of 0.1% ammonium water solution/methanol containing 0.1% ammonium water solution in negative mode, whereas the latter were determined with a mobile phase of 0.1% acetic acid solution/acetonitrile containing 0.1% acetic acid in negative mode. The limits of detection were less than 0.26 ng/mL for bisphenol analogues, 0.12 ng/mL for amphenicol antibiotics, and 0.14 ng/mL for phathalate metabolites. The recoveries of all target analytes in three fortification levels ranged from 72.02 to 117.64% with the relative standard deviations of no larger than 14.51%. The matrix effect was adjusted by isotopically labeled internal standards. This proposed method was successfully applied to analyze 40 actual urines and 13 out of 18 studied compounds were detected. Graphical abstract Simultaneous determination of nine bisphenol analogues, three amphenicol antibiotics, and six phthalate metabolites in human urine samples.


Assuntos
Antibacterianos/urina , Compostos Benzidrílicos/urina , Cloranfenicol/urina , Fenóis/urina , Ácidos Ftálicos/urina , Espectrometria de Massas em Tandem/métodos , Tianfenicol/análogos & derivados , Tianfenicol/urina , Antibacterianos/metabolismo , Compostos Benzidrílicos/metabolismo , Criança , Cloranfenicol/metabolismo , Cromatografia Líquida de Alta Pressão/métodos , Feminino , Humanos , Limite de Detecção , Masculino , Fenóis/metabolismo , Ácidos Ftálicos/metabolismo , Extração em Fase Sólida/métodos , Tianfenicol/metabolismo
8.
Anal Bioanal Chem ; 408(29): 8559-8567, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27734138

RESUMO

Different highly selective sorbents have been evaluated for the treatment of food and biological samples to determine chloramphenicol residues by ion mobility spectrometry (IMS). Combination of a selective solid-phase extraction (SPE) and dispersive liquid-liquid microextraction allowed a highly sensitive determination of chloramphenicol in water, milk, honey, and urine samples. The performance of selective SPE supports such as immunoaffinity chromatography (IAC) and molecular imprinted polymers (MIP) have been compared in terms of selectivity, sensitivity, trueness, precision, and reusability. Quantitative recoveries were obtained for chloramphenicol residues, ranging from 91 to 123 % for water, from 99 to 120 % for skimmed milk, and from 95 to 124 % for urine using IAC-IMS and MIP-IMS methods. Quantitative recoveries (from 88 to 104 %) were also achieved for honey samples using IAC-IMS, but low recoveries were obtained using MIP-IMS. The limit of quantification was set at 0.1 µg L-1 which is lower than the minimum required performance limit established by the EU. The proposed methodology is a simple and cost affordable alternative to chromatography methods for the highly sensitive and selective analysis of chloramphenicol residues in food and urine. Graphical Abstract Scheme for chloramphenicol determination by selective solid-phase extraction and ion mobility spectrometry.


Assuntos
Antibacterianos/urina , Cloranfenicol/urina , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Espectrometria de Mobilidade Iônica/métodos , Extração em Fase Sólida/métodos , Animais , Antibacterianos/análise , Cloranfenicol/análise , Análise de Alimentos/instrumentação , Voluntários Saudáveis , Mel/análise , Humanos , Espectrometria de Mobilidade Iônica/instrumentação , Limite de Detecção , Leite/química , Extração em Fase Sólida/instrumentação
9.
Chemistry ; 22(40): 14279-84, 2016 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-27529758

RESUMO

The sensing and accurate determination of antibiotics in various environments represents a big challenge, mainly owing to their widespread use in medicine, veterinary practice, and other fields. Therefore, a new, simple electrochemical sensor for the detection of antibiotic chloramphenicol (CAP) has been developed in this work. The amplification strategy of the sensor is based on the application of magnetite nanostructures stabilized with carboxymethyl cellulose (Fe3 O4 -CMC) and decorated with nanometer-sized Au nanoparticles (NPs) (Fe3 O4 -CMC@Au). In this case, CMC serves as a stabilizing agent, preventing the aggregation of Fe3 O4 NPs, and hence, enabling the kinetic barrier for electron transport to be overcome, and the Au NPs serve as an electron-conducting tunnel for better electron transport. As a proof of concept, the developed nanosensor is used for the detection of CAP in human urine samples, giving a recovery value of around 97 %, which indicates the high accuracy of the as-prepared nanosensor.


Assuntos
Antibacterianos/urina , Carboximetilcelulose Sódica/química , Cloranfenicol/urina , Técnicas Eletroquímicas/métodos , Ouro/química , Nanopartículas de Magnetita/química , Nanocompostos/química , Humanos , Limite de Detecção , Nanopartículas de Magnetita/ultraestrutura , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Nanocompostos/ultraestrutura
10.
Artigo em Inglês | MEDLINE | ID: mdl-27385382

RESUMO

Toxic effects of chloramphenicol in humans caused the ban for its use in food-producing animals in the EU. A minimum required performance level (MRPL) was specified for chloramphenicol at 0.3 µg kg(-1) for various matrices, including urine. In 2012, residues of chloramphenicol were found in pig urine and muscle without signs of illegal use. Regarding its natural occurrence in straw, it was hypothesised that this might be the source, straw being compulsory for use as bedding material for pigs in Sweden. Therefore, we investigated if low daily doses of chloramphenicol (4, 40 and 400 µg/pig) given orally during 14 days could result in residues in pig tissues and urine. A dose-related increase of residues was found in muscle, plasma, kidney and urine (showing the highest levels), but no chloramphenicol was found in the liver. At the lowest dose, residues were below the MRPL in all tissues except in the urine. However, in the middle dose, residues were above the MRPL in all tissues except muscle, and at the highest dose in all matrices. This study proves that exposure of pigs to chloramphenicol in doses occurring naturally in straw could result in residues above the MRPL in plasma, kidney and especially urine.


Assuntos
Ração Animal/análise , Cloranfenicol/administração & dosagem , Cloranfenicol/farmacocinética , Administração Oral , Animais , Cloranfenicol/sangue , Cloranfenicol/urina , Cromatografia Líquida de Alta Pressão , Relação Dose-Resposta a Droga , Comportamento Alimentar , Suínos , Espectrometria de Massas em Tandem , Distribuição Tecidual
11.
Biomed Chromatogr ; 30(12): 1935-1941, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27228157

RESUMO

Solid-phase membrane micro-tip extraction (SPMMTE) and capillary electrophoresis (CE) methods were developed and validated for analysis of chloramphenicol in human plasma and urine samples. Iron composite nanoparticles were prepared using green technology. CE was carried out using a silica capillary (60 cm × 50 µm i.d.), phosphate buffer (50 mm, 8.0 pH)-acetonitrile (95:5, v/v) as the background electrolyte, 10 kV voltage, 280 nm detection, 20 s injection time and 27 ± 1°C temperature. Frusemide was used as an internal standard. The values of migration time, electrophoretic mobility, electrophoretic velocity and theoretical plates of chloramphenicol were 12.254 min, 4.44 × 10, 7.41 × 10 and 11,227. The limits of detection and quantitation of chloramphenicol were 0.1 and 1.0 µg/mL. Recovery of chloramphenicol in the standard solution was 95%. Solid-phase membrane micro-tip extraction and capillary electrophoresis methods may be used to analyze chloramphenicol in human plasma and urine samples of any patient.


Assuntos
Cloranfenicol/análise , Eletroforese Capilar/métodos , Membranas Artificiais , Microextração em Fase Sólida/métodos , Cloranfenicol/sangue , Cloranfenicol/urina , Furosemida/sangue , Furosemida/urina , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Reprodutibilidade dos Testes
12.
Artigo em Inglês | MEDLINE | ID: mdl-26773882

RESUMO

This paper describes a method to reveal the illegal use of chloramphenicol (CAP) in animals intended for human consumption based on the detection of free CAP and chloramphenicol-glucuronide (CAP-glu) in urine. It details the different steps of the method, including hydrolysis of CAP-glu, extraction and cleanup with molecularly imprinted polymers and detection by LC-MS/MS, as well as the validation design. The efficiency of chloramphenicol release during the hydrolysis step and the stability of CAP-glu in urine samples stored at -20°C were also investigated. These verifications were important to ensure the method's suitability for checking CAP misuse in veterinary medicine. Validation results were fully compliant with the qualitative and quantitative criteria required by European regulations. Intraday relative standard deviations were all below 7.5%, while interday relative standard deviations were below 6.9%. Recoveries lay between 93.3 and 104.6%. Purification appears very effective since no matrix effect was demonstrated. CAP-glu was found to be stable for at least 3 months, and the mean recovery following deconjugation was assessed to be 79.4%. The decision limits (CCa) were all found to be lower than 0.1µg/kg.


Assuntos
Cloranfenicol/análogos & derivados , Cloranfenicol/urina , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Cloranfenicol/química , Estabilidade de Medicamentos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
13.
J Chromatogr A ; 1427: 1-7, 2016 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-26686562

RESUMO

Here we report a facile in situ solvothermal growth method for immobilization of metal-organic framework-ionic liquid functionalized graphene (MOF-5/ILG) composite on etched stainless steel wire. The X-ray diffraction spectra, scanning electron microscopy and transmission electron microscopy images showed that the metal organic framework possessed good crystal shape and its structure was not disturbed by the introduction of ILG. Moreover, the covalent bond established between the amino group of ILG and the carboxylic group of the metal organic framework improved the mechanical stability and structure uniformity of the microcrystals. The obtained material combined the favorable attributes of both metal-organic framework and ILG, having high surface area (820 m(2)/g) and good adsorption capability. Its adsorption properties were explored by preconcentrating chloramphenicol and thiamphenicol from aqueous solutions prior to gas chromatography-flame ionization detection. The MOF-5/ILG exhibited high enrichment capacity for the analytes as they could interact through π-π and H-bonding interaction. Under the optimum conditions, good linearity (correlation coefficients higher than 0.9981), low limits of detection (14.8-19.5 ng/L), and good precision (relative standard deviations less than 6.0% (n=5)) were achieved. The MOF-5/ILG composite displayed durable property. The method was applied to the determination of two antibiotics in milk, honey, urine and serum samples with acceptable relative recoveries of 82.3-103.2%.


Assuntos
Antibacterianos/análise , Cloranfenicol/análise , Grafite/química , Líquidos Iônicos/química , Nanocompostos/química , Tianfenicol/análise , Adsorção , Animais , Antibacterianos/sangue , Antibacterianos/urina , Cloranfenicol/sangue , Cloranfenicol/urina , Ionização de Chama , Mel/análise , Leite/química , Aço Inoxidável , Tianfenicol/sangue , Tianfenicol/urina
14.
J Chromatogr A ; 1218(41): 7331-40, 2011 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-21893319

RESUMO

Chloramphenicol is a broad-spectrum antibiotic with, apart from its human medicinal use, veterinary abuse in all major food-producing animals. Chloramphenicol occurs in four stereoisomers (all para-nitro substituted) and furthermore four meta-nitro analogs of chloramphenicol exist. In this paper these are referred to as eight chloramphenicol isomers. According to EU regulations an analytical method should be able to discriminate the analyte from interfering substances that might be present in the sample, including isomers. For the first time a quantitative method for the analysis of trace levels of eight chloramphenicol isomers in urine by chiral liquid chromatography in combination with tandem mass spectrometric detection is reported. The separation of the isomers on the analytical column, the clean-up of urine and the selectivity of the monitored product ions turned out to be critical parameters. To obtain reproducible retention isocratic elution on a chiral AGP column was applied. For urine samples matrix compounds present in the final extract caused decreased retention of the isomers on the chiral stationary phase and a lack of chromatographic resolution. Therefore an extended clean-up procedure that combines solid phase extraction and liquid-liquid extraction had to be developed. The final method was fully validated and showed satisfactory performance for all isomers with decision limits (CCα) ranging from 0.005 to 0.03 µg L(-1) and within-laboratory reproducibility of all isomers below 20% at the minimum required performance limit level of 0.3 µg L(-1).


Assuntos
Cloranfenicol/urina , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Cloranfenicol/química , Estabilidade de Medicamentos , Humanos , Análise dos Mínimos Quadrados , Extração Líquido-Líquido , Metanol/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Extração em Fase Sólida , Estereoisomerismo
15.
J Pharm Biomed Anal ; 53(3): 440-4, 2010 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-20658770

RESUMO

A solid phase microextraction--liquid chromatography with ultraviolet detection (SPME-LC-UV) method for the determination of the antimicrobial agent chloramphenicol was developed. The performances of three commercially available fibers were compared; the Carbowax/TPR-100 was found to provide the most efficient extraction. All the aspects influencing the fiber adsorption (extraction time, temperature, pH, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte were investigated. The method was eventually applied to the determination of the drug in both biological (urine) and environmental (tap and sea water) samples. The optimized procedure required a simple sample pretreatment, isocratic elution, and provided enough sensitivity for the analyte determination in the considered samples. The investigated linear ranges were 37-1000 ng/ml (urine), 0.1-10 ng/ml (tap water), 0.3-30 ng/ml (sea water). Within-day and between-days RSD% ranged between 5.5-6.2 and 8.7-9.0 (urine), 5.1-6.0 and 8.4-8.8 (tap water), 5.4-5.7 and 8.6-8.9 (sea water). Estimated LOD and LOQ were 37 and 95 ng/ml (urine), 0.1 and 0.3 ng/ml (tap water), 0.3 and 0.7 ng/ml (sea water).


Assuntos
Cloranfenicol/análise , Cromatografia Líquida/métodos , Água do Mar/análise , Microextração em Fase Sólida/métodos , Abastecimento de Água/análise , Cloranfenicol/urina , Humanos , Limite de Detecção
16.
J Chromatogr A ; 1216(46): 8246-53, 2009 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-19647262

RESUMO

A method for determination of low concentrations of chloramphenicol in urine, feed water, milk and honey was developed. A comparison was carried out between a routinely used analytical method based on solid phase extraction (SPE-C18) for cleaning the extract and the new procedure for the sample preparation using columns based on the molecular imprinted polymers (MIP) principle. The extracts obtained from the MIP clean-up procedure were clean enough for chromatografic analyses. Confirmatory analyses were conducted using GC/MS-NCI after derivatisation (silylation). The described method was fully validated according to CD 2002/657/EC. This method is considerably robust and allows very dirty samples to be processed. The described MIP procedure is very simple and low-time-consuming, and provides high throughput of the samples examined. This could be used for routine screening and confirmatory analyses as well.


Assuntos
Cloranfenicol/urina , Cromatografia/métodos , Mel/análise , Leite/química , Impressão Molecular , Água/análise , Ração Animal/análise , Animais , Antibacterianos/urina , Bovinos , Cromatografia/instrumentação , Polímeros/química , Suínos
17.
J Chromatogr A ; 1174(1-2): 63-71, 2007 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-17900594

RESUMO

A confirmatory method is described for the determination of the illegal antibiotic chloramphenicol using a specifically developed molecularly imprinted polymer (MIP) as the sample clean-up technique. The newly developed MIP was produced using an analogue to chloramphenicol as the template molecule. Using an analogue of the analyte as the template avoids a major traditional drawback associated with MIPs of residual template leeching or bleeding. The MIP described was used as a solid-phase extraction phase for the extraction of chloramphenicol from various sample matrices including honey, urine, milk and plasma. A full analytical method with quantification by LC-MS/MS is described. The method was fully validated according to the European Union (EU) criteria for the analysis of veterinary drug residues.


Assuntos
Técnicas de Química Analítica/métodos , Cloranfenicol/análise , Polímeros/química , Animais , Calibragem , Bovinos , Cloranfenicol/sangue , Cloranfenicol/urina , Mel/análise , Humanos , Reprodutibilidade dos Testes , Extração em Fase Sólida
18.
Rocz Panstw Zakl Hig ; 58(3): 503-8, 2007.
Artigo em Polonês | MEDLINE | ID: mdl-18246654

RESUMO

Chloropromazina (CP) is subjected to monitoring food animals products, with a minimum required performance limit (MPRL) set 5.0 microg/kg. Homogenized kidney and urine were extracted with acetonitrile. CP- d3 was used as internal standard. LC separation was done on Luna C18 150 x 2 mm, 5 microm column in mobile phase acetonitrile-acetic acid. CP was determination by LC-ESI-MS/MS negative mode. The method was validation according to the criteria of Decision Commission No 2002/657/EC. Recoveries for the level 5.0 ng/g were in the range 84-102%. The limit of decision (CCalpha) and detection capability (CCbeta) CP in kidney were 1.19; 2.87 ng/g and urine 1.08; 2.61 ng/g.


Assuntos
Antibacterianos/análise , Antibacterianos/urina , Cloranfenicol/análise , Cloranfenicol/urina , Resíduos de Drogas/análise , Rim/química , Carne/análise , Animais , Contaminação de Alimentos/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray
19.
J Chromatogr A ; 1118(2): 226-33, 2006 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-16631764

RESUMO

A simple and rapid method for the determination and confirmation of chloramphenicol in several food matrices with LC-MS/MS was developed. Following addition of d5-chloramphenicol as internal standard, meat, seafood, egg, honey and milk samples were extracted with acetonitrile. Chloroform was then added to remove water. After evaporation, the residues were reconstituted in methanol/water (3+4) before injection. The urine and plasma samples were after addition of internal standard applied to a Chem Elut extraction cartridge, eluted with ethyl acetate, and hexane washed. Also these samples were reconstituted in methanol/water (3+4) after evaporation. By using an MRM acquisition method in negative ionization mode, the transitions 321-->152, 321-->194 and 326-->157 were used for quantification, confirmation and internal standard, respectively. Quantification of chloramphenicol positive samples regardless of matrix could be achieved with a common water based calibration curve. The validation of the method was based on EU-decision 2002/657 and different ways of calculating CCalpha and CCbeta were evaluated. The common CCalpha and CCbeta for all matrices were 0.02 and 0.04 microg/kg for the 321-->152 ion transition, and 0.02 and 0.03 microg/kg for the 321-->194 ion transition. At fortification level 0.1 microg/kg the within-laboratory reproducibility is below 25%.


Assuntos
Cloranfenicol/análise , Cromatografia Líquida/métodos , Resíduos de Drogas/análise , Análise de Alimentos , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Calibragem , Cloranfenicol/sangue , Cloranfenicol/urina , Mel/análise , Produtos da Carne/análise , Leite/química , Reprodutibilidade dos Testes , Alimentos Marinhos/análise , Sensibilidade e Especificidade
20.
J Chromatogr B Biomed Sci Appl ; 715(2): 379-86, 1998 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-9792524

RESUMO

An immobilized enzyme reactor based upon beta-glucuronidase (BG-IMER) has been developed for the on-line deconjugation of substrates. The activity of the BG-IMER and its applicability to on-line deconjugation was investigated. The BG-IMER was coupled to a reversed-phase column (C8 or C18) and the latter column was used to separate substrates and products eluted from the beta-glucuronidase reactor. The activity of the BG-IMER was followed by measurement of percent deconjugation and the parameters investigated were: substrate concentration, pH (4 to 6), temperature (r.t., 37 degrees C), enzyme-substrate contact time using flow-rates of 0.1 to 1.0 min/min (15-1.5 min). The glucuronides used in the evaluation of the BG-IMER were: 4-methylumbelliferyl-beta-D-glucuronide, p-acetaminophen-beta-D-glucuronide, 3'-azido-3'-deoxythymidine-beta-D-glucuronide, phenyl-beta-D-glucuronide, chloramphenicol-beta-D-glucuronide, estradiol-17-beta-D-glucuronide and morphine-beta-D-glucuronide. The development of on-line HPLC deconjugation of glucuronide substrates using the BG-IMER will facilitate the identification of metabolites and quantification of aglycones in metabolic and pharmacokinetic studies.


Assuntos
Enzimas Imobilizadas/metabolismo , Glucuronatos/metabolismo , Glucuronidase/metabolismo , Cloranfenicol/análogos & derivados , Cloranfenicol/urina , Temperatura Alta , Humanos , Concentração de Íons de Hidrogênio , Hidrólise , Reprodutibilidade dos Testes , Especificidade por Substrato
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA