Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 546
Filtrar
1.
Tech Coloproctol ; 27(2): 91-101, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35915293

RESUMO

BACKGROUND: The effect of Endocuff-assisted colonoscopy compared with standard colonoscopy is conflicting in terms of the adenoma detection rate. The aim of this meta-analysis was to compare the efficacy of Endocuff-assisted colonoscopy for adenoma detection. METHODS: PubMed, Embase, Google Scholar and Cochrane Library were searched up to the end of June 8, 2021. All randomized controlled trials (RCTs) comparing Endocuff-assisted colonoscopy with standard colonoscopy were included. Dichotomous data were pooled to obtain the relative risk with a 95% CI, whereas continuous data were pooled using a mean difference with 95% CI. RESULTS: A total of 23 RCTs involving 17,999 patients were included. Compared with standard colonoscopy, use of the Endocuff was associated with a significant improvement in the adenoma detection rate (RR = 1.16, 95% CI 1.08-1.24), polyp detection rate (RR = 1.17, 95% CI 1.09-1.25), sessile serrated lesion detection rate (RR = 1.23, 95% CI 1.05-1.43), left-side lesion detection rate (RR = 1.24, 95% CI 1.08-1.43), and mean number of adenomas per patient (MD = 0.17, 95% CI 0.08-0.26). There were no significant differences between the and groups in detection of advanced adenomas, mean number of polyps per patient, right-side lesion detection rate, cecal intubation rate, cecal intubation time and withdrawal time. CONCLUSIONS: The pooled evidence suggests a significant improvement in the adenoma detection rate, and polyp detection rate using the Endocuff. On the other hand, no significant effect on the detection of advanced adenomas and mean number of polyps per patient was noted.


Assuntos
Adenoma , Pólipos do Colo , Colonoscopia , Humanos , Adenoma/diagnóstico , Adenoma/patologia , Ceco , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia/instrumentação , Colonoscopia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
BMC Gastroenterol ; 22(1): 531, 2022 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-36539692

RESUMO

OBJECTIVE: To investigate the effect of modified colonoscopy nursing pads in colonoscopy. METHODS: A total of 262 subjects who underwent colonoscopy at our endoscopy center between September 1, 2021 and February 28, 2022 were selected and randomly divided into a control group and an experimental group, with 131 cases in each group. The control group used conventional nursing pads, while the experimental group used modified nursing pads. The success rate of the first correct position, the time spent by the nurse to guide the correct position, the bed unit contamination rate, the contamination rate of the operator's protective equipment, the privacy protection of the examinees and the satisfaction degree after the examination were compared between the two groups. RESULTS: The success rate of the first correct position of the examinees in the experimental group was significantly higher than that of the control group (P < 0.05), and the time spent by the nurses to guide the correct position in the experimental group was less than that of the control group (P < 0.05). The bed unit contamination rate and operator's protective equipment contamination rate of the experimental group were lower than those of the control group, and the satisfaction degree of the examinees was higher in the experimental group than in the control group, and the differences were statistically significant (P < 0.05). CONCLUSION: The modified colonoscopy nursing pad can save the time of correct colonoscopy positioning of examinees, improve the efficiency of colonoscopy, reduce the workload of nursing staff, effectively protect the privacy of patients, reduce the bed unit contamination and protective equipment contamination, and then improve the comfort and satisfaction of patients.


Assuntos
Colonoscopia , Humanos , Colonoscopia/instrumentação , Posicionamento do Paciente
3.
Zhonghua Nei Ke Za Zhi ; 61(3): 310-316, 2022 Mar 01.
Artigo em Chinês | MEDLINE | ID: mdl-35263973

RESUMO

Objective: To evaluate the clinical application of LASEREO endoscopic system in early gastric cancer (EGC). Methods: A total of 68 patients diagnosed with EGC were retrospectively analyzed between August 2017 to December 2020 in Fuding Hospital Affiliated to Fujian University of Traditional Chinese Medicine. There were 50 males and 18 females finally enrolled with a median age of 64 years. EGCs were analyzed from subjective and objective aspect, as well as from magnification and non-magnification status. Six endoscopists evaluated the visibility of the EGC (RSC) and calculated the color difference (ΔEC) between EGC and the surrounding mucosa in white light imaging (WLI), blue light imaging-bright (BLI-Bri) and linked color imaging (LCI) modes. In the case of magnification (×80), the visibility of the microstructures and microvessels (RSV) was analyzed and the color difference (ΔEV) between microvessels and non-vessels areas were calculated in WLI, BLI and LCI modes. The visibility was evaluated using visibility ranking scale(RS) and the color difference (ΔE) was calculated using L*a*b* color space. Results: In WLI, BLI-Bri, and LCI modes, the mean (±SD) RSC were 2.56±0.68, 2.63±0.59 and 3.17±0.50, and the mean(±SD) ΔEC were 15.71±5.58, 12.04±3.73, and 22.84±8.46, respectively, which in LCI were higher than those in WLI and BLI-Bri modes (P<0.001).Regarding the data evaluated by senior endoscopists, the RSC was higher in BLI-Bri than that in WLI mode (2.98±0.58 vs. 2.79±0.73, P<0.001), but as to those evaluated by junior endoscopists, there were no significant differences between the WLI and BLI-Bri modes(2.29±0.72 vs. 2.23±0.72,P =0.218).In magnifying endoscopy with WLI, BLI, and LCI modes, the mean(±SD) RSV were 2.95±0.28, 3.46±0.40, and 3.38±0.33, and the mean (±SD) ΔEV were 21.68±7.52, 44.29±10.94, and 45.38±14.29, respectively.The RSV and ΔEV in LCI and BLI were higher than that in WLI mode (P<0.001). Conclusions: LCI improves the visibility of EGC by increasing ΔEC, especially in junior endoscopists. Both BLI and LCI improve the visibility of microstructures and microvessels under magnification.


Assuntos
Colonoscopia , Neoplasias Gástricas , Colonoscopia/instrumentação , Colonoscopia/métodos , Detecção Precoce de Câncer , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Gástricas/diagnóstico por imagem
4.
Dis Colon Rectum ; 65(2): e80-e84, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34840298

RESUMO

BACKGROUND: Curvilinear array ultrasound transducers enable tissue sampling and have therapeutic capabilities. Nevertheless, colonic intubation and maneuvering with these transducers is technically challenging and is therefore typically limited to the rectosigmoid area. This retrospective cohort study aimed to evaluate the safety, feasibility, and diagnostic yield of colonoscopic ultrasound-guided fine-needle aspiration in deep colonic intubation. IMPACT OF INNOVATION: The impact of this innovation is to enable tissue sampling of colonic and extracolonic lesions guided by endoscopic ultrasound. TECHNOLOGY, MATERIALS, AND METHODS: Curvilinear array ultrasound is used in the evaluation of luminal and extraluminal colonic diseases. Thirteen patients underwent colonoscopic ultrasound with a curvilinear array ultrasound endoscope in a single center for subepithelial lesions, cancer staging, and extracolonic lesions from July 2015 to February 2021. Endosonography was performed using an Olympus EU-ME1 and GF-UCT 180 with a 5-12MHz curvilinear array transducer. The primary outcome was the percentage of patients who were successfully scanned with the endoscopic ultrasound. The secondary outcomes included the success rate of fine-needle aspiration, the diagnostic yield of the tissue samples, and the adverse events related to the procedure. PRELIMINARY RESULTS: A total of 13 female patients underwent colonoscopic ultrasound. All patients (100%, 13/13) were successfully scanned. Fine-needle aspiration was deemed necessary and successfully performed in 100% (5/5) of the patients. Tissue samples collected by fine-needle aspiration resulted in a diagnostic yield of 60%, and no adverse events resulted from this intervention. CONCLUSIONS: This study demonstrates the feasibility of performing colonoscopic ultrasound with a curvilinear array transducer. Fine-needle aspiration for subepithelial, colonic, and extracolonic lesions is feasible and safe in this setting with no adverse events reported in our study. FUTURE DIRECTIONS: Future research should be directed toward validating colonoscopic ultrasound with a curvilinear array transducer technique in prospective randomized trials. Studies evaluating the feasibility and safety of endoscopic ultrasound-guided interventions in the colon, such as abscess drainage and enteral anastomosis, should be considered.


Assuntos
Doenças do Colo/patologia , Colonoscopia/instrumentação , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Endossonografia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças do Colo/diagnóstico por imagem , Colonoscopia/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Endossonografia/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
J Gastroenterol Hepatol ; 36(12): 3268-3277, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34622488

RESUMO

BACKGROUND AND AIM: Sessile serrated adenoma/polyp (SSA/P) may contribute to interval cancer. In a recent meta-analysis, water exchange (WE) was shown to be superior to Endocuff and cap colonoscopy at adenoma and advanced adenoma detection. The strong positive correlation between adenoma detection rate (ADR), advanced adenoma detection rate (AADR), and sessile serrated adenoma/polyp detection rate (SSA/PDR) prompted us to hypothesize that WE could significantly improve SSA/PDR compared with Endocuff and cap colonoscopy. METHODS: The literature was searched for all randomized controlled trials (RCTs) that reported SSA/PDR as an outcome and included the keywords colonoscopy, and water exchange, Endocuff, or cap. We performed traditional network meta-analyses with random effect models comparing SSA/PDR of each method using air insufflation as the control and reported the odds ratios (ORs) with 95% confidence interval (CI). Performances were ranked based on P-score. RESULTS: A total of 531 articles resulted from initial keywords search. Eleven RCTs were included in the analysis. A total of 7856 patients underwent air insufflation, WE, Endocuff, or cap colonoscopy. WE significantly increased SSA/PDR (OR 2.04; 95% CI 1.33-3.13). Endocuff (OR 1.15; 95% CI 0.94-1.41) and cap (OR 1.08; 95% CI 0.42-2.74) did not significantly impact SSA/P detection. P-scores for WE (0.96), Endocuff (0.49), cap (0.37), and air insufflation (0.17) suggested that WE had the highest SSA/PDR. The results did not change after adjusting for mean withdrawal time and indication for colonoscopy. CONCLUSION: Water exchange significantly increases SSA/PDR and is superior to Endocuff and cap colonoscopy at detecting SSA/P.


Assuntos
Adenoma , Pólipos do Colo , Colonoscopia/métodos , Adenoma/diagnóstico , Adenoma/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Colonoscopia/instrumentação , Humanos , Metanálise em Rede , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/patologia , Água
7.
Sci Rep ; 11(1): 18674, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34548571

RESUMO

Endoscopic submucosal dissection (ESD) is challenging in the right colon. Traction devices can make it technically easier. In this study, we evaluated a flexible grasper with articulating tip and elbow-like bending (IgE) through a double-balloon surgical platform (DESP), compared with an earlier generation grasper without elbow-like bending (Ig). The reach of Ig/IgE was investigated at eight locations using a synthetic colon within a 3D model. Using a fresh porcine colorectum, 4 cm pseudo-polyps were created at the posterior wall of the ascending colon. Fifty-four ESD procedures were performed using three techniques: standard ESD (STD), ESD using Ig (DESP + Ig), and ESD using IgE (DESP + IgE). IgE was able to reach the full circumference at all the locations, whereas the medial walls proximal to the descending colon were out of Ig's reach. Compared with the STD, both DESP + Ig and DESP + IgE showed significantly shorter procedure time (STD vs. DESP + Ig vs. DESP + IgE = median 48.9 min vs. 38.6 vs. 29.9) and fewer injuries (1.5 vs. 0 vs. 0). Moreover, the DESP + IgE had a shorter procedure time than the DESP + Ig (p = 0.0025). The IgE with DESP increased instrument reach compared to Ig, and likely represented a traction tool for excision of large pseudo-polyps in the right colon.


Assuntos
Pólipos do Colo/cirurgia , Colonoscopia/instrumentação , Animais , Ressecção Endoscópica de Mucosa/métodos , Suínos
8.
Medicine (Baltimore) ; 100(31): e26763, 2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34397820

RESUMO

BACKGROUND AND AIMS: water is an imperfect agent for lens cleansing during endoscopy due to its incompetence to clean hydrophobic dirt, whereas amphiphilic surfactants have the potential to overcome the limitation of water. The trial was aimed to evaluate the cleansing effectiveness of 2 typical surfactants (simethicone solution and oolong tea) for colonoscopic lens. METHODS: Oolong tea (O-), low concentration simethicone solution (S1-), high concentration simethicone solution (S2-) and distilled water (D-) were used as washing solutions for colonoscopic lens. Study I: The tip of the colonoscope was immersed in lard oil in order to simulate the blur, and photographs were taken toward a standard colonoscopy image in-vitro pre- and post- each cleansing procedure. The blurred areas of each image were quantified and compared. Study II: 395 consecutive patients who were due to colonoscopy examination were enrolled and randomized into O-, S2-, D-group. The volume of washing solution used and cleansing level during the examination procedure, adenoma and polyp detected per colonoscopy, insertion time and withdraw time were analyzed. RESULTS: Study I: There were no differences in 4 groups for the blurred areas on images before lens cleansing. The blurred areas after lens cleansing were significantly smaller in 3 groups (O- 8.47 ±â€Š20.91 vs S1- 13.06 ±â€Š10.71 vs S2- 6.76 ±â€Š8.49 vs D- 38.24 ±â€Š29.69, P < .05) than water. The decline range of blurred areas after lens cleansing in oolong tea, low concentration simethicone solution, high concentration simethicone solution groups were significantly higher than that in distilled water group (O- 87.35 ±â€Š20.81 vs S1- 78.12 ±â€Š19.24 vs S2- 89.57 ±â€Š8.50 vs D- 53.39 ±â€Š28.45, P < .05). Study II: The volume of washing solution used in S2-group was significantly smaller than that in O-group and D-group. The cleansing level of the colonoscopic lens of O-group was significantly superior than that of S2-group and D-group. CONCLUSIONS: The in-vitro test showed oolong tea and simethicone solution can effectively cleans the colonoscopic lens. The clinical trial demonstrated that oolong tea instead of water is effective to provide better visualization during colonoscopy.Registration: Chictr.org.cn No: ChiCTR1900025606.


Assuntos
Colonoscopia/instrumentação , Manutenção/normas , Simeticone/uso terapêutico , Chá , Colonoscopia/métodos , Método Duplo-Cego , Reutilização de Equipamento/normas , Humanos , Manutenção/métodos , Manutenção/estatística & dados numéricos , Simeticone/farmacologia , Água/administração & dosagem
9.
J Gastroenterol ; 56(8): 746-757, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34218329

RESUMO

BACKGROUND: We have developed the computer-aided detection (CADe) system using an original deep learning algorithm based on a convolutional neural network for assisting endoscopists in detecting colorectal lesions during colonoscopy. The aim of this study was to clarify whether adenoma miss rate (AMR) could be reduced with CADe assistance during screening and surveillance colonoscopy. METHODS: This study was a multicenter randomized controlled trial. Patients aged 40 to 80 years who were referred for colorectal screening or surveillance at four sites in Japan were randomly assigned at a 1:1 ratio to either the "standard colonoscopy (SC)-first group" or the "CADe-first group" to undergo a back-to-back tandem procedure. Tandem colonoscopies were performed on the same day for each participant by the same endoscopist in a preassigned order. All polyps detected in each pass were histopathologically diagnosed after biopsy or resection. RESULTS: A total of 358 patients were enrolled and 179 patients were assigned to the SC-first group or CADe-first group. The AMR of the CADe-first group was significantly lower than that of the SC-first group (13.8% vs. 36.7%, P < 0.0001). Similar results were observed for the polyp miss rate (14.2% vs. 40.6%, P < 0.0001) and sessile serrated lesion miss rate (13.0% vs. 38.5%, P = 0.03). The adenoma detection rate of CADe-assisted colonoscopy was 64.5%, which was significantly higher than that of standard colonoscopy (53.6%; P = 0.036). CONCLUSION: Our study results first showed a reduction in the AMR when assisting with CADe based on deep learning in a multicenter randomized controlled trial.


Assuntos
Inteligência Artificial/normas , Colonoscopia/instrumentação , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Inteligência Artificial/estatística & dados numéricos , Colonoscopia/métodos , Colonoscopia/estatística & dados numéricos , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Robóticos/instrumentação , Procedimentos Cirúrgicos Robóticos/métodos
10.
Sci Rep ; 11(1): 6460, 2021 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-33742067

RESUMO

We developed a magnetic-assisted capsule colonoscope system with integration of computer vision-based object detection and an alignment control scheme. Two convolutional neural network models A and B for lumen identification were trained on an endoscopic dataset of 9080 images. In the lumen alignment experiment, models C and D used a simulated dataset of 8414 images. The models were evaluated using validation indexes for recall (R), precision (P), mean average precision (mAP), and F1 score. Predictive performance was evaluated with the area under the P-R curve. Adjustments of pitch and yaw angles and alignment control time were analyzed in the alignment experiment. Model D had the best predictive performance. Its R, P, mAP, and F1 score were 0.964, 0.961, 0.961, and 0.963, respectively, when the area of overlap/area of union was at 0.3. In the lumen alignment experiment, the mean degrees of adjustment for yaw and pitch in 160 trials were 21.70° and 13.78°, respectively. Mean alignment control time was 0.902 s. Finally, we compared the cecal intubation time between semi-automated and manual navigation in 20 trials. The average cecal intubation time of manual navigation and semi-automated navigation were 9 min 28.41 s and 7 min 23.61 s, respectively. The automatic lumen detection model, which was trained using a deep learning algorithm, demonstrated high performance in each validation index.


Assuntos
Colonoscópios/normas , Automação , Ceco/diagnóstico por imagem , Ceco/patologia , Colonoscopia/instrumentação , Colonoscopia/métodos , Diagnóstico por Computador/métodos , Diagnóstico por Computador/normas , Desenho de Equipamento , Humanos , Fenômenos Magnéticos , Sensibilidade e Especificidade
11.
J Gastroenterol Hepatol ; 36(7): 1778-1787, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33638894

RESUMO

BACKGROUND AND AIM: It is not clear whether prophylactic clipping after endoscopic mucosal resection (EMR) of large nonpedunculated colorectal lesions (LNPCLs) prevents delayed bleeding (DB). We aimed to conduct a meta-analysis to clarify the efficacy of prophylactic clipping in prevention of DB following EMR of LNPCLs. METHODS: We searched PubMed, EMBASE, Web of Science, ScienceDirect, Cochrane Library databases, and ClinicalTrials.gov for studies that compared clipping versus (vs) nonclipping in prevention of DB following EMR of LNPCLs. Pooled odds ratio (OR) was determined using a random effects model. The pooled ORs of DB, perforation, and post-polypectomy syndrome in the clipping group compared with the nonclipping group comprised the outcomes. Subgroup analyses based on study design, polyp location, and completeness of wound closure were performed. RESULTS: Five studies with a total of 3112 LNPCLs were extracted. Prophylactic clipping reduced the risk of DB compared with nonclipping (3.3% vs 6.2%, OR: 0.494, P = 0.002) following EMR of LNPCLs. In subgroup analysis, prophylactic clipping reduced DB of LNPCLs at proximal location (3.8% vs 9.8%, P = 0.029), but not of them at distal location (P = 0.830). Complete wound closure showed superior efficacy to prevent DB compared with partial closure (2.0% vs 5.4%, P = 0.004). No benefit of clipping for preventing perforation or post-polypectomy syndrome was observed (P = 0.301 and 0.988, respectively). CONCLUSIONS: Prophylactic clipping can reduce DB following EMR of LNPCLs at proximal location. Besides, complete wound closure showed superior efficacy to prevent DB compared with partial closure. Further cost analyses should be conducted to implement the most cost-effective strategies.


Assuntos
Colonoscopia , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa , Pólipos/cirurgia , Hemorragia Pós-Operatória/prevenção & controle , Colonoscopia/efeitos adversos , Colonoscopia/instrumentação , Colonoscopia/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/instrumentação , Ressecção Endoscópica de Mucosa/métodos , Humanos , Hemorragia Pós-Operatória/etiologia , Instrumentos Cirúrgicos , Fatores de Tempo
12.
Dig Dis Sci ; 66(12): 4448-4456, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33386521

RESUMO

BACKGROUNDS: Endoscopic tattooing failure by deep mural injection or tattoo leakage-induced massive staining causes localization errors or decreased laparoscopic visualization. To overcome these, we developed a novel tattoo needle with comparatively shorter needle (length, 2.5 mm) and minimal-caliber catheter (volume, 0.3 mL). AIMS: The single-center, prospective observational study aimed to determine the efficacy and safety of a small-doze endoscopic tattooing prior to laparoscopic surgery for colorectal cancer, using the needle. METHODS: Patients with colorectal cancer indicated for laparoscopic surgery were recruited. With the novel needle, a single tattoo was created at the anterior wall close to the lesion. During laparoscopic surgery, surgeons assessed the tattoo visibility, tattoo leakage, and the disturbance of laparoscopic view by tattoo leakage. The primary endpoint was an accurate localization by visible tattoo. Secondary endpoints were adverse events related to tattooing, the need for intraoperative endoscopy, and tattoo leakage. RESULTS: A total of 383 tattoos in 358 patients were analyzed. Accurate tumor localization rate was 96.6% (95% confidence interval [CI]: 94.3-98.0%). No adverse events occurred. Intraoperative colonoscopy was performed in 7 (1.8%) patients with invisible tattoo. Tattoo leakage was found in 4.2% (95%CI: 2.6-6.7%), and leakage disturbed the laparoscopic view of the surgical plane in 0.7% (95%CI: 0.3-2.3%). CONCLUSIONS: Prior to laparoscopic surgery for colorectal cancer, our endoscopic tattooing with a standardized protocol using a novel needle is considered a simple, highly reliable localization technique with an extremely safe profile, which would be valuable to reduce physician's efforts and redundant medical resources. Trial registration number UMIN000021012. Date of registration: June 2016.


Assuntos
Colonoscopia/instrumentação , Neoplasias Colorretais/cirurgia , Agulhas , Tatuagem/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Colo/cirurgia , Feminino , Humanos , Laparoscopia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reto/cirurgia , Tatuagem/efeitos adversos , Tatuagem/estatística & dados numéricos
13.
Dis Colon Rectum ; 64(2): 241-247, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33394769

RESUMO

BACKGROUND: Colorectal endoscopic submucosal dissection is typically performed by specialized knife, such as a dual knife. However, it is not covered by Taiwan's National Health Insurance. In the literature review, using a traditional snare tip for endoscopic submucosal dissection has been reported for stomach lesions only. OBJECTIVE: The purpose of this study was to evaluate the outcomes of colorectal endoscopic submucosal dissection using a snare tip. DESIGN: We retrospectively reviewed the clinical using of a snare tip compared with a dual knife for colorectal endoscopic submucosal dissection. Postoperative short- and long-term outcomes were investigated after the procedure. SETTINGS: This study was conducted at a single tertiary care institution. PATIENTS: Patients who could not afford the expense of a specialized knife were included. MAIN OUTCOME MEASURES: Dissection time, dissection speed, and perioperative complications were used for short-term outcome measurement. Recurrence-free rate was used for long-term outcome measurement. RESULTS: Twenty-one lesions were in the snare tip group and 57 lesions in the dual knife group. The outcomes, including rate of en bloc resection, complication, local recurrence, and recurrence-free interval, between the 2 groups were similar. The mean resected specimen diameter in the dual knife group is larger than the snare tip group (p = 0.041). The dissection time of the snare tip group was shorter than the dual knife group (p = 0.025). However, the dissection speed was significantly slower in the snare tip group than in the dual knife group (p = 0.008). LIMITATIONS: This study was a retrospective and single doctor chart review in nature with a limited patient number. CONCLUSIONS: The snare tip is an alternative tool for colorectal endoscopic submucosal dissection in a selected population without the support of specialized knives, such as the dual knife. Although the dissection speed is slower using a snare tip, it is still a recommended technique for developing country or low-income patients.


Assuntos
Adenocarcinoma/cirurgia , Adenoma/cirurgia , Pólipos do Colo/cirurgia , Colonoscopia/instrumentação , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/instrumentação , Adenocarcinoma/diagnóstico por imagem , Adenoma/diagnóstico por imagem , Adulto , Idoso , Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico por imagem , Intervalo Livre de Doença , Ressecção Endoscópica de Mucosa/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
14.
Surg Endosc ; 35(2): 620-625, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32072275

RESUMO

BACKGROUND: Missed adenomas are the main concern for endoscopists. Right colon retroflexion (RCR) seems to increase the adenoma detection rate (ADR), but important variation in success and usefulness of this maneuver has been reported in the literature AIMS: Primary objective: to assess additional adenoma detection rate (AADR) detected during the RCR attempt. Secondary objectives: to assess success rates of RCR, variables associated with it, and safety of RCR. METHODS: This is a prospective, unicentric, non-randomized study. Consecutive colonoscopies done by six endoscopists (3 of them with < 3 years of experience and 3 with > 3 years) from March to May 2017 were included. Olympus colonoscopes were used (CF-H190, CF-H180) Demographic, clinical, and endoscopic variables were collected. RESULTS: 463 colonoscopies were included. RCR success rate was 93.1% (431/463 colonoscopies). Forty additional lesions were visualized during RCR in 34/463 colonoscopies (7.3%). Additional adenomas were detected in 31/463 colonoscopies (6.7%; OR 0.07). HISTOLOGY: low-grade dysplasia adenomas in 29/40 (72.5%) lesions; 3/40 (7.5%), adenomas with high-grade dysplasia; and 7/40 (17.5%) sessile serrated lesions. Additional adenoma detection contributed to modify the colonoscopy surveillance interval in 25 patients (5.4% of the cohort). Variables associated with RCR success in multivariate analysis were no previous abdominal surgery, length of colonoscope insertion in cecum < 80 cm, and use of Olympus 190 series colonoscopes. No differences between endoscopists' experience were found. RCR was a safe maneuver, with no adverse events in our study. CONCLUSIONS: RCR is a feasible and safe maneuver that can increase ADR, so its routine inclusion in colonoscopy practice should be considered.


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias do Colo/diagnóstico por imagem , Colonoscopia/métodos , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Ceco , Colo/diagnóstico por imagem , Colo/patologia , Neoplasias do Colo/patologia , Colonoscópios , Colonoscopia/efeitos adversos , Colonoscopia/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
15.
Surg Endosc ; 35(3): 1171-1181, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32128607

RESUMO

BACKGROUND: Colonoscopies are considered to be the primary screening test and gold standard test for colorectal cancer. Position changes during colonoscope withdrawal are believed to be associated with an increased adenoma detection rate (ADR) and polyp detection rate (PDR). However, previous results conflicted, and this study aimed to elucidate the effectiveness of dynamic position changes during colonoscope withdrawal. METHODS: The relevant publications were identified by searching the medical databases. The primary outcomes were the ADR and PDR, which were pooled and analyzed. The secondary outcome was the withdrawal time. The studies that supplied the ADR and PDR for different segments of the colon were separated into subgroup analyses. RESULTS: Five randomized controlled trials were eligible for analysis. The total ADR was higher with dynamic position changes than with a static position (odds ratio, [OR] 1.34; 95% confidence interval [CI] 1.13-1.59; p < 0.001), with low evidence of between-study heterogeneity (I2 = 0%). Although the total PDR was slightly higher with dynamic position changes than with a static position (OR 1.23; 95% CI 0.88-1.73), there difference was not statistically significant (p = 0.22). The withdrawal time was only increased by 0.47 min (95% CI - 0.11 to 1.06) with dynamic position changes, without statistical significance (p = 0.11). The subgroup analysis showed that the ADR and PDR for the transverse colon were higher with dynamic position changes, with pooled estimates of ADR (OR 1.72; 95% CI 1.02-2.88; p = 0.04) and PDR (OR 1.79; 95% CI 1.08-2.96; p = 0.02). CONCLUSION: Dynamic position changes during colonoscope withdrawal increased the total ADR; however, no obvious increase was found in the total PDR. The withdrawal time was not significantly prolonged with dynamic position changes. Subgroup analysis showed that the ADR and PDR in the transverse colon were obviously improved with dynamic position changes.


Assuntos
Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Adenoma/diagnóstico , Colo Transverso/diagnóstico por imagem , Colo Transverso/patologia , Colonoscópios , Colonoscopia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Ensaios Clínicos Controlados Aleatórios como Assunto
16.
Dig Dis Sci ; 66(8): 2756-2762, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32808142

RESUMO

BACKGROUND: Adenoma detection rate (ADR) is an important quality indicator of colonoscopy. High-definition (HD) colonoscopy has been reported to increase ADR compared to standard-definition (SD) colonoscopy. Although there are few reports comparing the latest generation and the previous generation of HD colonoscopy equipment, there are reports that the latest generation colonoscopy equipment improves ADR. However, there are no reports on the impact of the latest generation HD colonoscopy on the ADR of trainee endoscopists. AIMS: The aim of this study was to investigate whether the latest generation HD colonoscopy increases the ADR of trainee endoscopists compared with the previous generation HD colonoscopy. METHOD: We conducted a retrospective review of medical records of patients aged 40-79 years old, who underwent screening or surveillance colonoscopy performed by nine gastroenterology fellows at Dong-A University Hospital from March 2019 to February 2020. We calculated the overall ratios of the ADR: the ADRs of the group using the older generation HD colonoscopy equipment and the group using the latest HD colonoscopy equipment. Polyp detection rate (PDR), sessile serrated polyp detection rate (SSPDR), and advanced neoplasia detection rate (ANDR) were calculated for each group. Factors related to adenoma detection were identified using logistic regression analysis. RESULTS: Altogether, 2189 patients were included in the study (the older HD colonoscopy group comprising 1183 and the latest HD colonoscopy group comprising 1006). We found that PDR (45.98 vs. 51.69%, p = 0.008) and ADR (35.67 vs. 40.85%, p = 0.013) were significantly higher in the latest generation HD colonoscopy group. The generational differences were not statistically significant for SSPDR (1.94 vs. 2.78%, p = 0.195) or ANDR (4.65 vs. 4.97%, p = 0.726). In the multivariate regression analysis, age, male sex, the latest generation HD colonoscopy, and long withdrawal time were the most significant factors affecting adenoma detection. CONCLUSIONS: The latest generation HD colonoscopy improved PDR and ADR by trainee endoscopists. These findings suggest that latest generation, higher-resolution colonoscopy equipment can improve the quality of colonoscopy for less experienced endoscopists.


Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Pólipos do Colo/diagnóstico , Colonoscopia/instrumentação , Gastroenterologia/educação , Adenoma/patologia , Adulto , Idoso , Detecção Precoce de Câncer , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
United European Gastroenterol J ; 9(4): 443-450, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33349200

RESUMO

BACKGROUND AND AIMS: Adenoma detection rate (ADR) in colon cancer screening is most important for cancer prophylaxis. This work is the first three-armed randomised controlled clinical trial aimed at comparing a head-to-head setting standard colonoscopy (SC) with Endocuff-assisted colonoscopy (EC) and cap-assisted colonoscopy (CAC) for improvement of ADR. METHODS: Patients from Poland and Germany with independent indication for colonoscopy were randomised into three arms of this trial: EC, CAC and SC. Exclusion criteria were age <18 years, active Crohn's disease or ulcerative colitis, known stenosis and post-colonic resection status. RESULTS: A total of 585 patients (195 SC, 189 EC and 186 CAC) were enrolled in this study. Indications were not different between the groups (colorectal cancer screening 51%, diagnostic colonoscopy in 31% and post-polypectomy follow-up in 18%; p = 0.94). Withdrawal time was a mean of 7 min in all groups (p = 0.658), and bowel preparation did not differ between the groups. The time to reach the caecum was significantly reduced when using the cap (a mean of 6 min for CAC vs. 7 min for SC; p = 0.0001). There was no significant difference in the primary outcome of the ADR between the groups (EC 32%, CAC 30%, SC 30%; p = 0.815). EC proved to be superior (EC vs. SC) in the sigmoid colon and transverse colon for polyp detection. CONCLUSION: The use of EC increased the total number of polyps seen during colonoscopy. In contrast to recent studies, no significant improvement of the ADR was detected.


Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Pólipos do Colo/diagnóstico , Colonoscopia/métodos , Detecção Precoce de Câncer/métodos , Idoso , Colonoscopia/efeitos adversos , Colonoscopia/instrumentação , Detecção Precoce de Câncer/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
18.
J Gastroenterol Hepatol ; 36(2): 376-382, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33141979

RESUMO

BACKGROUND AND AIM: AmplifEYE is a mucosal exposure device mounted to the tip of colonoscope to improve polyp or adenoma detection. We aim to compare the adenoma detection rates (ADR) of AmplifEYE-assisted colonoscopy (AC) with standard colonoscopy (SC). METHODS: We performed a randomized controlled trial involving patients aged 50 to 79 who underwent AC or SC in two centers. Procedures were performed by five experienced colonoscopists. RESULTS: Three hundred fifty-five patients were recruited, with 334 patients (170 AC and 164 SC) included into analysis. The ADR was numerically higher in AC (47.1%) versus SC (40.9%), P = 0.253. The polyp detection rate (PDR) in AC was 68.2% versus 54.3% in SC, P = 0.009, and serrated polyp detection rate (SDR) in AC was 37.6% versus 20.1% in SC, P < 0.001, both statistically significant higher in the study group. The mean cecal intubation time was shorter with AmplifEYE (8.0 min in AC vs 8.9 min in SC, P = 0.030), and there was no difference in pain score (3 in AC vs 4 in SC, P = 0.121). CONCLUSIONS: AmplifEYE-assisted colonoscopy significantly improved the PDR and SDR, while the ADR was numerically higher in AC that did not reach statistical significance. Using the device resulted in shorter cecal intubation time and did not cause more pain.


Assuntos
Adenoma/diagnóstico , Neoplasias do Colo/diagnóstico , Colonoscopia/instrumentação , Colonoscopia/normas , Cirurgia Assistida por Computador/instrumentação , Adenoma/patologia , Idoso , Ceco/patologia , Neoplasias do Colo/patologia , Pólipos do Colo/diagnóstico , Pólipos do Colo/patologia , Feminino , Humanos , Mucosa Intestinal/patologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia
20.
J Gastroenterol Hepatol ; 36(7): 1738-1743, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33295071

RESUMO

BACKGROUND AND AIM: Either clipping or band ligation will become the most common endoscopic treatment for colonic diverticular bleeding (CDB). Rebleeding is a significant clinical outcome of CDB, but there is no cumulative evidence comparing reduction of short-term and long-term rebleeding between them. Thus, we conducted a systematic review and meta-analysis to determine which endoscopic treatment is more effective to reduce recurrence of CDB. METHODS: A comprehensive search of the databases PubMed/MEDLINE and Embase was performed through December 2019. Main outcomes were early and late rebleeding rates, defined as bleeding within 30 days and 1 year of endoscopic therapy for CDB. Initial hemostasis, need for transcatheter arterial embolization, or surgery were also assessed. Overall pooled estimates were calculated. RESULTS: Sixteen studies fulfilled the eligibility criteria, and a total of 790 participants were included. The pooled prevalence of early rebleeding was significantly lower for band ligation than clipping (0.08 vs 0.19; heterogeneity test, P = 0.012). The pooled prevalence of late rebleeding was significantly lower for band ligation than clipping (0.09 vs 0.29; heterogeneity test, P = 0.024). No significant difference of initial hemostasis rate was noted between the two groups. Pooled prevalence of need for transcatheter arterial embolization or surgery was significantly lower for band ligation than clipping (0.01 vs 0.02; heterogeneity test, P = 0.031). There were two cases with colonic diverticulitis due to band ligation but none in clipping. CONCLUSION: Band ligation therapy was more effective compared with clipping to reduce recurrence of colonic diverticular hemorrhage over short-term and long-term durations.


Assuntos
Colonoscopia , Divertículo do Colo , Hemorragia Gastrointestinal/prevenção & controle , Hemostase Endoscópica , Colonoscopia/instrumentação , Colonoscopia/métodos , Divertículo do Colo/complicações , Hemorragia Gastrointestinal/etiologia , Hemostase Endoscópica/instrumentação , Hemostase Endoscópica/métodos , Humanos , Ligadura/instrumentação , Ligadura/métodos , Prevenção Secundária/métodos , Instrumentos Cirúrgicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA