Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.165
Filtrar
1.
Int J Mol Sci ; 25(8)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38674004

RESUMO

Phenolic compounds, originating from industrial, agricultural, and urban sources, can leach into flowing waters, adversely affecting aquatic life, biodiversity, and compromising the quality of drinking water, posing potential health hazards to humans. Thus, monitoring and mitigating the presence of phenolic compounds in flowing waters are essential for preserving ecosystem integrity and safeguarding public health. This study explores the development and performance of an innovative sensor based on screen-printed electrode (SPE) modified with graphene (GPH), poly(3,4-ethylenedioxythiophene) (PEDOT), and tyrosinase (Ty), designed for water analysis, focusing on the manufacturing process and the obtained electroanalytical results. The proposed biosensor (SPE/GPH/PEDOT/Ty) was designed to achieve a high level of precision and sensitivity, as well as to allow efficient analytical recoveries. Special attention was given to the manufacturing process and optimization of the modifying elements' composition. This study highlights the potential of the biosensor as an efficient and reliable solution for water analysis. Modification with graphene, the synthesis and electropolymerization deposition of the PEDOT polymer, and tyrosinase immobilization contributed to obtaining a high-performance and robust biosensor, presenting promising perspectives in monitoring the quality of the aquatic environment. Regarding the electroanalytical experimental results, the detection limits (LODs) obtained with this biosensor are extremely low for all phenolic compounds (8.63 × 10-10 M for catechol, 7.72 × 10-10 M for 3-methoxycatechol, and 9.56 × 10-10 M for 4-methylcatechol), emphasizing its ability to accurately measure even subtle variations in the trace compound parameters. The enhanced sensitivity of the biosensor facilitates detection and quantification in river water samples. Analytical recovery is also an essential aspect, and the biosensor presents consistent and reproducible results. This feature significantly improves the reliability and usefulness of the biosensor in practical applications, making it suitable for monitoring industrial or river water.


Assuntos
Técnicas Biossensoriais , Compostos Bicíclicos Heterocíclicos com Pontes , Grafite , Monofenol Mono-Oxigenase , Fenóis , Polímeros , Rios , Poluentes Químicos da Água , Técnicas Biossensoriais/métodos , Grafite/química , Rios/química , Polímeros/química , Fenóis/análise , Poluentes Químicos da Água/análise , Compostos Bicíclicos Heterocíclicos com Pontes/química , Enzimas Imobilizadas/química , Técnicas Eletroquímicas/métodos , Eletrodos , Limite de Detecção
2.
Int J Biol Macromol ; 267(Pt 1): 131321, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570001

RESUMO

The improper usage of levofloxacin (LEV) endangers both environmental safety and human public health. Therefore, trace analysis and detection of LEV have extraordinary significance. In this paper, a novel molecularly imprinted polymer (MIP) electrochemical sensor was developed for the specific determination of LEV by electrochemical polymerization of o-phenylenediamine (o-PD) using poly(3,4-ethylenedioxythiophene)/chitosan (PEDOT/CS) with a porous structure and rich functional groups as a carrier and LEV as a template molecule. The morphology, structure and properties of the modified materials were analyzed and studied. The result showed that the electron transfer rate and the electroactive strength of the electrode surface are greatly improved by the interconnection of PEDOT and CS. Meanwhile, PEDOT/CS was assembled by imprinting with o-PD through non-covalent bonding, which offered more specific recognition sites and a larger surface area for the detection of LEV and effectively attracted LEV through intermolecular association. Under the optimized conditions, MIP/PEDOT/CS/GCE showed good detection performance for LEV in a wide linear range of 0.0019- 1000 µM, with a limit of detection (LOD, S/N = 3) of 0.4 nM. Furthermore, the sensor has good stability and selectivity, and exhibits excellent capabilities in the microanalysis of various real samples.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Quitosana , Técnicas Eletroquímicas , Levofloxacino , Impressão Molecular , Polímeros Molecularmente Impressos , Polímeros , Quitosana/química , Levofloxacino/análise , Levofloxacino/química , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Impressão Molecular/métodos , Técnicas Eletroquímicas/métodos , Polímeros Molecularmente Impressos/química , Eletrodos , Limite de Detecção , Humanos
3.
Drug Dev Res ; 85(3): e22193, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38685605

RESUMO

The scaffolds of two known CDK inhibitors (CAN508 and dinaciclib) were the starting point for synthesizing two series of pyarazolo[1,5-a]pyrimidines to obtain potent inhibitors with proper selectivity. The study presented four promising compounds; 10d, 10e, 16a, and 16c based on cytotoxic studies. Compound 16a revealed superior activity in the preliminary anticancer screening with GI % = 79.02-99.13 against 15 cancer cell lines at 10 µM from NCI full panel 60 cancer cell lines and was then selected for further investigation. Furthermore, the four compounds revealed good safety profile toward the normal cell lines WI-38. These four compounds were subjected to CDK inhibitory activity against four different isoforms. All of them showed potent inhibition against CDK5/P25 and CDK9/CYCLINT. Compound 10d revealed the best activity against CDK5/P25 (IC50 = 0.063 µM) with proper selectivity index against CDK1 and CDK2. Compound 16c exhibited the highest inhibitory activity against CDK9/CYCLINT (IC50 = 0.074 µM) with good selectivity index against other isoforms. Finally, docking simulations were performed for compounds 10e and 16c accompanied by molecular dynamic simulations to understand their behavior in the active site of the two CDKs with respect to both CAN508 and dinaciclib.


Assuntos
Antineoplásicos , Compostos Bicíclicos Heterocíclicos com Pontes , Óxidos N-Cíclicos , Desenho de Fármacos , Indolizinas , Simulação de Acoplamento Molecular , Inibidores de Proteínas Quinases , Compostos de Piridínio , Humanos , Compostos de Piridínio/farmacologia , Compostos de Piridínio/química , Indolizinas/farmacologia , Indolizinas/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Compostos Bicíclicos Heterocíclicos com Pontes/química , Óxidos N-Cíclicos/farmacologia , Óxidos N-Cíclicos/química , Inibidores de Proteínas Quinases/farmacologia , Inibidores de Proteínas Quinases/síntese química , Inibidores de Proteínas Quinases/química , Linhagem Celular Tumoral , Antineoplásicos/farmacologia , Antineoplásicos/síntese química , Antineoplásicos/química , Quinases Ciclina-Dependentes/antagonistas & inibidores , Relação Estrutura-Atividade , Pirimidinas/farmacologia , Pirimidinas/química , Ensaios de Seleção de Medicamentos Antitumorais , Quinase 5 Dependente de Ciclina/antagonistas & inibidores , Quinase 5 Dependente de Ciclina/metabolismo , Quinase 9 Dependente de Ciclina/antagonistas & inibidores , Quinase 9 Dependente de Ciclina/metabolismo
4.
Food Chem ; 449: 139114, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38581782

RESUMO

L-Tryptophan (L-Trp) is essential for the human body and can only be obtained externally. It is important to develop a method to efficiently detect L-Trp in food. In this work, ionic liquid (IL) modified poly(3,4-ethylendioxythiophene)/ Titanium carbide (PEDOT/Ti3C2TX) was used as a substrate material to improve detection sensitivity. Molecular imprinted polymers (MIP) film for specific recognition of L-Trp was fabricated on the surface of modified electrodes using electrochemical polymerization. The monitoring results showed that the molecularly imprinted electrochemical sensors (MIECS) exhibited good linearity ranges (10-6 - 0.1 µM and 0.1-100 µM) with a low detection limit (LOD) of 2.09 × 10-7 µM. In addition, the MIECS exhibited remarkable stability, reproducibility, and immunity to interference. A good recovery (93.54-99.59%) was demonstrated in the detection of milk. The sensor was expected to be developed as a highly selective and sensitive portable assay, and applied to the detection of L-Trp in food.


Assuntos
Técnicas Eletroquímicas , Líquidos Iônicos , Limite de Detecção , Leite , Impressão Molecular , Polímeros , Titânio , Triptofano , Leite/química , Líquidos Iônicos/química , Polímeros/química , Animais , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Triptofano/análise , Triptofano/química , Titânio/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Polímeros Molecularmente Impressos/química , Contaminação de Alimentos/análise , Eletrodos , Reprodutibilidade dos Testes
5.
Biomater Adv ; 160: 213830, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38552500

RESUMO

Cancer, namely breast and prostate cancers, is the leading cause of death in many developed countries. Controlled drug delivery systems are key for the development of new cancer treatment strategies, to improve the effectiveness of chemotherapy and tackle off-target effects. In here, we developed a biomaterials-based wireless electrostimulation system with the potential for controlled and on-demand release of anti-cancer drugs. The system is composed of curcumin-loaded poly(3,4-ethylenedioxythiophene) nanoparticles (CUR/PEDOT NPs), encapsulated inside coaxial poly(glycerol sebacate)/poly(caprolactone) (PGS/PCL) electrospun fibers. First, we show that the PGS/PCL nanofibers are biodegradable, which allows the delivery of NPs closer to the tumoral region, and have good mechanical properties, allowing the prolonged storage of the PEDOT NPs before their gradual release. Next, we demonstrate PEDOT/CUR nanoparticles can release CUR on-demand (65 % of release after applying a potential of -1.5 V for 180 s). Finally, a wireless electrostimulation platform using this NP/fiber system was set up to promote in vitro human prostate cancer cell death. We found a decrease of 67 % decrease in cancer cell viability. Overall, our results show the developed NP/fiber system has the potential to effectively deliver CUR in a highly controlled way to breast and prostate cancer in vitro models. We also show the potential of using wireless electrostimulation of drug-loaded NPs for cancer treatment, while using safe voltages for the human body. We believe our work is a stepping stone for the design and development of biomaterial-based future smarter and more effective delivery systems for anti-cancer therapy.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Glicerol/análogos & derivados , Nanopartículas , Poliésteres , Polímeros , Tecnologia sem Fio , Humanos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Nanopartículas/química , Polímeros/química , Poliésteres/química , Curcumina/administração & dosagem , Curcumina/química , Glicerol/química , Masculino , Neoplasias da Próstata/terapia , Antineoplásicos/administração & dosagem , Decanoatos/química , Nanofibras/química , Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Linhagem Celular Tumoral , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos
6.
Adv Mater ; 36(19): e2312735, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38290128

RESUMO

Devices interfacing with biological tissues can provide valuable insights into function, disease, and metabolism through electrical and mechanical signals. However, certain neuromuscular tissues, like those in the gastrointestinal tract, undergo significant strains of up to 40%. Conventional inextensible devices cannot capture the dynamic responses in these tissues. This study introduces electrodes made from poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and polydimethylsiloxane (PDMS) that enable simultaneous monitoring of electrical and mechanical responses of gut tissue. The soft PDMS layers conform to tissue surfaces during gastrointestinal movement. Dopants, including Capstone FS-30 and polyethylene glycol, are explored to enhance the conductivity, electrical sensitivity to strain, and stability of the PEDOT:PSS. The devices are fabricated using shadow masks and solution-processing techniques, providing a faster and simpler process than traditional clean-room-based lithography. Tested on ex vivo mouse colon and human stomach, the device recorded voltage changes of up to 300 µV during contraction and distension consistent with muscle activity, while simultaneously recording resistance changes of up to 150% due to mechanical strain. These devices detect and respond to chemical stimulants and blockers, and can induce contractions through electrical stimulation. They hold great potential for studying and treating complex disorders like irritable bowel syndrome and gastroparesis.


Assuntos
Dimetilpolisiloxanos , Poliestirenos , Animais , Camundongos , Poliestirenos/química , Humanos , Dimetilpolisiloxanos/química , Contração Muscular/fisiologia , Eletrodos , Trato Gastrointestinal/fisiologia , Estômago/fisiologia , Colo/fisiologia , Condutividade Elétrica , Polímeros/química , Fenômenos Eletrofisiológicos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Tiofenos/química , Tiofenos/farmacologia
7.
Biomacromolecules ; 25(2): 644-654, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38170167

RESUMO

Nanocellulose constitutes promising resources for next-generation electronics, particularly when incorporated with conductive polymers due to their abundance, renewability, processability, biodegradability, flexibility, and mechanical performance. In this study, electrically conducting cellulose nanofibers were fabricated through in situ chemical polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT) on the surface of sulfuric acid-treated cellulose nanofibers (SACN). The utilization of highly crystalline SACN extracted from tunicate yielded synergistic effects in PEDOT polymerization for achieving a highly conductive and molecularly uniform coating. Polymerization parameters, such as monomer concentration, molar ratio with oxidants, and temperature, were systematically investigated. High electrical conductivity of up to 57.8 S cm-1 was obtained without utilizing the classical polystyrenesulfonate dopant. The resulting nanocomposite demonstrates the unique advantages of both electrically conductive PEDOT and mechanically robust high-crystalline cellulose nanofibers. As a proof-of-applicational concept, an electrical circuit was drawn with SACN-PEDOT as the conductive ink on flexible paper using a simple commercial extrusion-based printer. Furthermore, the flame-retardant property of SACN-PEDOT was demonstrated owing to the high crystallinity of SACN, effective char formation, and high conductivity of PEDOT. The multifunctional SACN-PEDOT developed in this study shows great promise to be employed in versatile applications as a low-cost, ecofriendly, flexible, and sustainable electrically conductive material.


Assuntos
Celulose , Nanofibras , Celulose/química , Nanofibras/química , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química
8.
Artigo em Inglês | MEDLINE | ID: mdl-38083429

RESUMO

We have developed a novel composite filler with Poly(3,4-ethylenedioxythiophene) : poly(styrenesulfonic acid) (PEDOT:PSS), a biocompatible organic conductive polymer, adsorbed on carbon particles for biological electrodes. This composite filler enables to fabricate high-performance biological electrodes simply by adding it to resin in the same way as conventional conductive fillers. The fabricated electrodes achieve ion exchange properties similar to those of PEDOT:PSS polymers and therefore low skin and electrode contact impedance. Electroencephalogram (EEG) measurements show that these electrodes capture various brain activities and exhibit high correlation (≥ 0.9) to commercially available wet and AgCl electrodes. Additionally, each electrode can be molded into various shapes and structures while retaining its electrode characteristics. Therefore, the proposed electrode is promising for EEG measurement, which requires high comfort and signal quality.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Polímeros , Compostos Bicíclicos Heterocíclicos com Pontes/química , Eletrodos , Polímeros/química , Condutividade Elétrica , Eletroencefalografia
9.
Biomater Adv ; 154: 213655, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37866232

RESUMO

In the field of bioelectronics, the demand for biocompatible, stable, and electroactive materials for functional biological interfaces, sensors, and stimulators, is drastically increasing. Conductive polymers (CPs) are synthetic materials, which are gaining increasing interest mainly due to their outstanding electrical, chemical, mechanical, and optical properties. Since its discovery in the late 1980s, the CP Poly(3,4-ethylenedioxythiophene):poly(styrene sulfonic acid) (PEDOT:PSS) has become extremely attractive, being considered as one of the most capable organic electrode materials for several bioelectronic applications in the field of tissue engineering and regenerative medicine. Main examples refer to thin, flexible films, electrodes, hydrogels, scaffolds, and biosensors. Within this context, the authors contend that PEDOT:PSS properties should be customized to encompass: i) biocompatibility, ii) conductivity, iii) stability in wet environment, iv) adhesion to the substrate, and, when necessary, v) (bio-)degradability. However, consolidating all these properties into a single functional solution is not always straightforward. Therefore, the objective of this review paper is to present various methods for acquiring and improving PEDOT:PSS properties, with the primary focus on ensuring its biocompatibility, and simultaneously addressing the other functional features. The last section highlights a collection of designated studies, with a particular emphasis on PEDOT:PSS/carbon filler composites due to their exceptional characteristics.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Polímeros , Compostos Bicíclicos Heterocíclicos com Pontes/química , Condutividade Elétrica , Eletricidade
10.
Chembiochem ; 24(23): e202300502, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37708237

RESUMO

The development of designer topological structures is a synthetically challenging endeavor. We present herein bispidine as a platform for the design of molecules with various topologies and functions. The bispidine-based acyclic molecule, which shows intriguing S-shape topology, is discussed. Single-crystal X-ray diffraction studies revealed that this molecule exists in the solid state as two conformational enantiomers. In addition, bispidine-based designer macrocycles were synthesized and investigated for ionophoric properties. Patch clamp experiments revealed that these macrocycles transport both anions and cations non-specifically with at least tenfold higher chloride conductance over the cations under the given experimental conditions. Ultramicroscopy and single-crystal X-ray crystallographic studies indicated that the self-assembling macrocycle forms a tubular assembly. Our design highlights the use of unconventional dihydrogen interactions in nanotube fabrication.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Ionóforos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Transporte Biológico , Cátions
11.
Int J Biol Macromol ; 248: 125870, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37473889

RESUMO

Flexible highly conductive fibers have attracted much attention due to their great potential in the field of wearable electronic devices. In this work, silk/PEDOT conductive fibers with a resistivity of 1.73 Ω·cm were obtained by oxidizing Ce3+ with H2O2 under alkaline conditions to produce CeO2 and further promote the in-situ polymerization of 3,4-ethylenedioxythiophene (EDOT) on the surface of silk fibers. The morphology and chemical composition of the silk/PEDOT conductive fibers were characterized and the results confirmed that a large amount of polythiophene was synthesized and deposited on the surface of silk fibers. The conductivity and electrochemical property stability of the silk/PEDOT conductive fibers were evaluated by soaping and organic solvent immersion, and the conductive silk fibers exhibited excellent environmental stability and durability. The silk/PEDOT conductive fibers show good pressure sensing and strain sensing performance, which exhibits high sensitivity, fast response and cyclability, and have excellent applications in personal health monitoring, human-machine information transmission, etc.


Assuntos
Seda , Dispositivos Eletrônicos Vestíveis , Humanos , Seda/química , Peróxido de Hidrogênio , Compostos Bicíclicos Heterocíclicos com Pontes/química
12.
Bioelectrochemistry ; 153: 108484, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37302335

RESUMO

The continuous progression in the field of electrotherapies implies the development of multifunctional materials exhibiting excellent electrochemical performance and biocompatibility, promoting cell adhesion, and possessing antibacterial properties. Since the conditions favouring the adhesion of mammalian cells are similar to conditions favouring the adhesion of bacterial cells, it is necessary to engineer the surface to exhibit selective toxicity, i.e., to kill or inhibit the growth of bacteria without damaging mammalian tissues. The aim of this paper is to introduce a surface modification approach based on a subsequent deposition of silver and gold particles on the surface of a conducting polymer, poly(3,4-ethylenedioxythiophene) (PEDOT). The resulting PEDOT-Au/Ag surface is found to possess optimal wettability, roughness, and surface features making it an excellent platform for cell adhesion. By depositing Ag particles on PEDOT surface decorated with Au particles, it is possible to reduce toxic effects of Ag particles, while maintaining their antibacterial activity. Besides, electroactive and capacitive properties of PEDOT-Au/Ag account for its applicability in various electroceutical therapies.


Assuntos
Ouro , Prata , Animais , Prata/farmacologia , Prata/química , Ouro/química , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Compostos Bicíclicos Heterocíclicos com Pontes/química , Antibacterianos/farmacologia , Mamíferos
13.
AAPS PharmSciTech ; 24(5): 118, 2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37165275

RESUMO

To address the limitations of norcantharidin (NCTD) in clinical applications, including restricted tumor accumulation and intense irritation, we have developed a new derivative of NCTD with (S)-1-benzyl-3-pyrrolidinol, which can be actively loaded into liposomes to achieve drug encapsulation and sustained release properties by using pH gradient loading technique. Cytotoxicity tests against cancer cell lines (Hepa 1-6 and 4 T1 cells) have demonstrated that this derivative exhibits comparable activity to NCTD in vitro. The NCTD derivative can be efficiently loaded into liposomes with high encapsulation efficiency (98.7%) and high drug loading (32.86%). Tolerability and antitumor efficacy studies showed that the liposomal NCTD derivative was well tolerated at intravenous injection doses of 3 folds higher than the parent drug solution, while significantly improved anticancer activity in vivo was achieved. This liposomal nanodrug could become a potent and safe NCTD formulation alternative for cancer therapy.


Assuntos
Antineoplásicos , Nanopartículas , Lipossomos/química , Portadores de Fármacos/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Nanopartículas/uso terapêutico , Nanopartículas/química , Linhagem Celular Tumoral
14.
Phys Biol ; 20(4)2023 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-37080214

RESUMO

Conventionally, only the normal cell membrane fluctuations have been studied and used to ascertain membrane properties like the bending rigidity. A new concept, the membrane local slope fluctuations was introduced recently (Vaippullyet al2020Soft Matter167606), which can be modelled as a gradient of the normal fluctuations. It has been found that the power spectral density (PSD) of slope fluctuations behave as (frequency)-1while the normal fluctuations yields (frequency)-5/3even on the apical cell membrane in the high frequency region. In this manuscript, we explore a different situation where the cell is applied with the drug Latrunculin-B which inhibits actin polymerization and find the effect on membrane fluctuations. We find that even as the normal fluctuations show a power law (frequency)-5/3as is the case for a free membrane, the slope fluctuations PSD remains (frequency)-1, with exactly the same coefficient as the case when the drug was not applied. Moreover, while sometimes, when the normal fluctuations at high frequency yield a power law of (frequency)-4/3, the pitch PSD still yields (frequency)-1. Thus, this presents a convenient opportunity to study membrane parameters like bending rigidity as a function of time after application of the drug, while the membrane softens. We also investigate the active athermal fluctuations of the membrane appearing in the PSD at low frequencies and find active timescales of slower than 1 s.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Membrana Celular , Tiazolidinas , Compostos Bicíclicos Heterocíclicos com Pontes/química , Tiazolidinas/química
15.
Sci Rep ; 13(1): 5826, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-37037876

RESUMO

The PEDOT polymer electrode is a metal-free electrode, consisting of an acrylate (dental composite) and the conductive polymer poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). The electrode is applied as gel onto the skin and cured with blue light for 10-20 s in order to achieve a conductive bond to the skin. The electrodes are used in combination with polymer cables consisting of a textile backbone and PEDOT:PSS. To test this new electrode and cable type under different conditions we designed two stress-tests: highly sensitive temperature recordings within a head phantom during Magnetic Resonance Imaging (MRI) and long-term stability inside a climate chamber with high humidity. To study the physical behavior inside the strong magnetic field (3 Tesla), the PEDOT polymer electrode was attached to an agarose head-phantom inside a magnetic resonance tomograph during an image sequence. MRI-safe temperature sensors were placed nearby in order to measure possible heating effects. In comparison to a metal cable, nearly no rise in temperature could be observed if the electrode was used in combination with a conductive textile cable. Furthermore, the electrode showed stable impedance values inside a climate chamber for 4 consecutive days. These results pave the way for testing the PEDOT polymer electrode as biosignal recording electrode during MRI, especially for cardio MRI and Electroencephalography in combination with functional MRI (EEG-fMRI).


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Polímeros , Eletrodos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Polímeros/química , Imageamento por Ressonância Magnética
16.
J Neural Eng ; 20(1)2023 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-36603213

RESUMO

Conductive polymers are of great interest in the field of neural electrodes because of their potential to improve the interfacial properties of electrodes. In particular, the conductive polymer poly (3,4)-ethylenedioxithiophene (PEDOT) has been widely studied for neural applications.Objective:This review compares methods for electrodeposition of PEDOT on metal neural electrodes, and analyses the effects of deposition methods on morphology and electrochemical performance.Approach:Electrochemical performances were analysed against several deposition method choices, including deposition charge density and co-ion, and correlations were explained to morphological and structural arguments as well as characterisation methods choices.Main results:Coating thickness and charge storage capacity are positively correlated with PEDOT electrodeposition charge density. We also show that PEDOT coated electrode impedance at 1 kHz, the only consistently reported impedance quantity, is strongly dependent upon electrode radius across a wide range of studies, because PEDOT coatings reduces the reactance of the complex impedance, conferring a more resistive behaviour to electrodes (at 1 kHz) dominated by the solution resistance and electrode geometry. This review also summarises how PEDOT co-ion choice affects coating structure and morphology and shows that co-ions notably influence the charge injection limit but have a limited influence on charge storage capacity and impedance. Finally we discuss the possible influence of characterisation methods to assess the robustness of comparisons between published results using different methods of characterisation.Significance:This review aims to serve as a common basis for researchers working with PEDOT by showing the effects of deposition methods on electrochemical performance, and aims to set a standard for accurate and uniform reporting of methods.


Assuntos
Materiais Revestidos Biocompatíveis , Galvanoplastia , Materiais Revestidos Biocompatíveis/química , Eletrodos , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia
17.
ACS Biomater Sci Eng ; 9(5): 2156-2169, 2023 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-35687654

RESUMO

Poly(3,4-ethylenedioxythiophene) polystyrenesulfonate (PEDOT:PSS) is a highly conductive, easily processable, self-healing polymer. It has been shown to be useful in bioelectronic applications, for instance, as a biointerfacing layer for studying brain activity, in biosensitive transistors, and in wearable biosensors. A green and biofriendly method for improving the mechanical properties, biocompatibility, and stability of PEDOT:PSS involves mixing the polymer with a biopolymer. Via structural changes and interactions with PEDOT:PSS, biopolymers have the potential to improve the self-healing ability, flexibility, and electrical conductivity of the composite. In this work, we fabricated novel protein-polymer multifunctional composites by mixing PEDOT:PSS with genetically programmable amyloid curli fibers produced byEscherichia coli bacteria. Curli fibers are among the stiffest protein polymers and, once isolated from bacterial biofilms, can form plastic-like thin films that heal with the addition of water. Curli-PEDOT:PSS composites containing 60% curli fibers exhibited a conductivity 4.5-fold higher than that of pristine PEDOT:PSS. The curli fibers imbued the biocomposites with an immediate water-induced self-healing ability. Further, the addition of curli fibers lowered the Young's and shear moduli of the composites, improving their compatibility for tissue-interfacing applications. Lastly, we showed that genetically engineered fluorescent curli fibers retained their ability to fluoresce within curli-PEDOT:PSS composites. Curli fibers thus allow to modulate a range of properties in conductive PEDOT:PSS composites, broadening the applications of this polymer in biointerfaces and bioelectronics.


Assuntos
Materiais Biocompatíveis , Polímeros , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Bactérias , Água
18.
Molecules ; 27(23)2022 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-36500418

RESUMO

Tissue engineering scaffolds provide biological and physiochemical cures to guide tissue recovery, and electrical signals through the electroactive materials possess tremendous potential to modulate the cell fate. In this study, a novel electroactive hydrogel scaffold was fabricated by assembling poly(3,4-ethylenedioxythiophene) (PEDOT) nanoparticles on a carboxymethyl chitosan/gelatin (CMCS/Gel) composite hydrogel surface via in situ chemical polymerization. The chemical structure, morphology, conductivity, porosity, swelling rate, in vitro biodegradation, and mechanical properties of the prepared hydrogel samples were characterized. The adhesion, proliferation, and differentiation of neural stem cells (NSCs) on conductive hydrogels were investigated. The CMCS/Gel-PEDOT hydrogels exhibited high porosity, excellent water absorption, improved thermal stability, and adequate biodegradability. Importantly, the mechanical properties of the prepared hydrogels were similar to those of brain tissue, with electrical conductivity up to (1.52 ± 0.15) × 10-3 S/cm. Compared to the CMCS/Gel hydrogel, the incorporation of PEDOT nanoparticles significantly improved the adhesion of NSCs, and supported long-term cell growth and proliferation in a three-dimensional (3D) microenvironment. In addition, under the differentiation condition, the conductive hydrogel also significantly enhanced neuronal differentiation with the up-regulation of ß-tubulin III expression. These results suggest that CMCS/Gel-PEDOT hydrogels may be an attractive conductive substrate for further studies on neural tissue repair and regeneration.


Assuntos
Quitosana , Células-Tronco Neurais , Hidrogéis/farmacologia , Hidrogéis/química , Quitosana/farmacologia , Quitosana/química , Gelatina/farmacologia , Gelatina/química , Compostos Bicíclicos Heterocíclicos com Pontes/farmacologia , Compostos Bicíclicos Heterocíclicos com Pontes/química , Polímeros/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Diferenciação Celular , Proliferação de Células
19.
Molecules ; 27(22)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36431851

RESUMO

Cantharidin (CTD) is the main active ingredient isolated from Mylabris, and norcantharidin (NCTD) is a demethylated derivative of CTD, which has similar antitumor activity to CTD and lower toxicity than CTD. However, the clinical use of NCTD is limited due to its poor solubility, low bioavailability, and toxic effects on normal cells. To overcome these shortcomings, researchers have explored a number of strategies, such as chemical structural modifications, microsphere dispersion systems, and nanodrug delivery systems. This review summarizes the structure-activity relationship of NCTD and novel strategies to improve the solubility and bioavailability of NCTD as well as reduce the toxicity. This review can provide evidence for further research of NCTD.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Cantaridina , Solubilidade , Disponibilidade Biológica , Compostos Bicíclicos Heterocíclicos com Pontes/química , Cantaridina/farmacologia
20.
Anal Chem ; 94(46): 15956-15963, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36350813

RESUMO

Poly(3,4-ethylenedioxythiophene)-polyethylene glycol (PEDOT:PEG) is a conductive material adopted in bioelectronics due to its biocompatibility and stability. While PEDOT has established its utility in cationic solid-contact ion-selective electrodes (sc-ISEs), its anionic counterpart remains less explored. Herein, we report the first example of PEDOT:PEG as a solution-printable solid-contact for all-solid-state nitrate-selective electrodes and a simple ion exchange treatment which can significantly enhance nitrate selectivity. Electrochemical impedance spectroscopy revealed that the sc-ISEs with perchlorate (ClO4-)-doped PEDOT:PEG suffered a large overall resistance. Removal of the ClO4- dopant via ion exchange reduced the resistance, resulting in significant improvement in sc-ISE performance. The optimal sc-ISE exhibited near-Nernstian response (-55.8 mV/decade) across a wide dynamic range (0.1 M to 1.12 µM) and excellent Hofmeister selectivity, which was maintained after prolonged continuous usage. This simple drop-cast and ion-exchange protocol is amenable to the scalable preparation of flexible anion sc-ISEs.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Nitratos , Eletrodos , Compostos Bicíclicos Heterocíclicos com Pontes/química , Eletrodos Seletivos de Íons , Ânions
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA