Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.428
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Saudi Med J ; 45(5): 495-501, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38734423

RESUMO

OBJECTIVES: To investigate the prevalence of hematologic findings and the relationship between hemogram parameters and brucellosis stages in patients. METHODS: This multi-center study included patients older than 16 years of age who were followed up with a diagnosis of brucellosis. Patients' results, including white blood cell, hemoglobin, neutrophil, lymphocyte, monocyte, mean platelet volume, platelet and eosinophil counts were analyzed at the initial diagnosis. RESULTS: In this study 51.3% of the patients diagnosed with brucellosis were male. The age median was 45 years for female and 41 years for male. A total of 55.1% of the patients had acute brucellosis, 28.2% had subacute, 7.4% had chronic and 9% had relapse. The most common hematologic findings in brucellosis patients were anemia (25.9%), monocytosis (15.9%), eosinopenia (10.3%), and leukocytosis (7.1%). Pancytopenia occurred in 0.8% of patients and was more prominent in the acute phase. The acute brucellosis group had lower white blood cell, hemoglobin, neutrophil, eosinophil, and platelet counts and mean platelet volume, and higher monocyte counts compared to subacute and chronic subgroups. CONCLUSION: It was noteworthy that in addition to anemia and monocytosis, eosinopenia was third most prominent laboratory findings in the study. Pancytopenia and thrombocytopenia rates were low.


Assuntos
Brucelose , Humanos , Brucelose/epidemiologia , Brucelose/sangue , Brucelose/complicações , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Turquia/epidemiologia , Adulto Jovem , Trombocitopenia/epidemiologia , Trombocitopenia/sangue , Adolescente , Idoso , Anemia/epidemiologia , Anemia/sangue , Anemia/etiologia , Contagem de Células Sanguíneas
2.
Clin Lab ; 70(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747905

RESUMO

BACKGROUND: Cold agglutinins (CAs) in blood samples can cause a reversible agglutination of red blood cell (RBC) which result in an incorrect complete blood count (CBC). So, it is important to explore new simple and feasible treatment conditions for clinical work. METHODS: The CAs group included 32 samples with CAs. The parameters of CBC at room temperature or after prewarming at 37°C or 41°C for different time periods were compared. The consistency and correlation of those parameters were analyzed. The morphology of erythrocytes in the CAs group was observed manually. The control group included 45 samples without CAs and prewarmed at 37°C or 41°C for different time periods. The differences were also analyzed. RESULTS: CAs have a significant effect on CBC. After prewarming at 37°C or 41°C the interferences are all corrected. Consider prewarming at 37°C for 120 minutes as the standard procedure. The consistency and correlation analysis showed there was no statistical difference between the results of each subgroup and standard group, except the MCHC of group 41°C 10 minutes. The correlation of parameters between all subgroups and the standard group is satisfied. Microscopic examination showed no RBC aggregation or fragmentation after prewarming at 41°C or 37°C. According to the maximum bias requirements for expert performance in Validation, Verification, and Quality Assurance of Automated Hematology Analyzers, 2nd Edition (CLSI H26-A2), the differences in overall results in control group are negligible. CONCLUSIONS: The 41°C 2 minutes prewarming method is a rapid and effective way for treating samples with CAs. It is an efficient way to obtain more reliable CBC results, without specific instruments.


Assuntos
Crioglobulinas , Eritrócitos , Humanos , Crioglobulinas/análise , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo , Agregação Eritrocítica , Aglutinação
3.
Sci Rep ; 14(1): 10841, 2024 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-38736010

RESUMO

Optimizing early breast cancer (BC) detection requires effective risk assessment tools. This retrospective study from Brazil showcases the efficacy of machine learning in discerning complex patterns within routine blood tests, presenting a globally accessible and cost-effective approach for risk evaluation. We analyzed complete blood count (CBC) tests from 396,848 women aged 40-70, who underwent breast imaging or biopsies within six months after their CBC test. Of these, 2861 (0.72%) were identified as cases: 1882 with BC confirmed by anatomopathological tests, and 979 with highly suspicious imaging (BI-RADS 5). The remaining 393,987 participants (99.28%), with BI-RADS 1 or 2 results, were classified as controls. The database was divided into modeling (including training and validation) and testing sets based on diagnostic certainty. The testing set comprised cases confirmed by anatomopathology and controls cancer-free for 4.5-6.5 years post-CBC. Our ridge regression model, incorporating neutrophil-lymphocyte ratio, red blood cells, and age, achieved an AUC of 0.64 (95% CI 0.64-0.65). We also demonstrate that these results are slightly better than those from a boosting machine learning model, LightGBM, plus having the benefit of being fully interpretable. Using the probabilistic output from this model, we divided the study population into four risk groups: high, moderate, average, and low risk, which obtained relative ratios of BC of 1.99, 1.32, 1.02, and 0.42, respectively. The aim of this stratification was to streamline prioritization, potentially improving the early detection of breast cancer, particularly in resource-limited environments. As a risk stratification tool, this model offers the potential for personalized breast cancer screening by prioritizing women based on their individual risk, thereby indicating a shift from a broad population strategy.


Assuntos
Neoplasias da Mama , Aprendizado de Máquina , Humanos , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Idoso , Contagem de Células Sanguíneas/métodos , Medição de Risco/métodos , Detecção Precoce de Câncer/métodos , Brasil/epidemiologia
4.
Eur Rev Med Pharmacol Sci ; 28(8): 3135-3143, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38708472

RESUMO

OBJECTIVE: Benzene is one of the major carcinogenic factors that can affect liver, kidneys, and lungs. Chronic inhalation of benzene vapor by petrol stations workers has been shown to have an impact on hematological parameters; thus, the present study aimed to investigate the effect of benzene exposure on petrol station workers. SUBJECTS AND METHODS: The study involved 99 participants, 50 of whom have been exposed to benzene and 49 of whom have not (control). A 5 ml blood sample in an ethylenediaminetetraacetic acid (EDTA) anticoagulant tube was collected from each subject, and a complete blood count test was used to test hematological parameters. RESULTS: The current study showed a significant decrease in red blood cells, packed cell volume, and hemoglobin in the exposed group compared to the control group. However, the amount of white blood cells was significantly increased (p < 0.0001) in the exposed group compared to the control group. Notably, there was no significant difference in platelet counts between the two groups. In terms of exposure time, subjects who have been exposed to benzene for more than a year and fewer than 10 years showed a significant decrease (p < 0.05) in RBCs indices and a significant increase (p < 0.0001) in WBCs compared to those in the control group CONCLUSIONS: Thus, the findings indicated that significant differences in hematological parameters were found in workers who were exposed to benzene compared to those who had not been exposed.


Assuntos
Benzeno , Exposição Ocupacional , Humanos , Exposição Ocupacional/efeitos adversos , Benzeno/toxicidade , Adulto , Masculino , Contagem de Células Sanguíneas , Hemoglobinas/análise , Hemoglobinas/metabolismo , Pessoa de Meia-Idade
5.
J Clin Apher ; 39(3): e22114, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38708583

RESUMO

BACKGROUND: Stem cell apheresis in the context of autologous stem cell transplantation requires an accurate cluster of differentiantion 34 (CD34+) count determined by flow cytometry as the current gold standard. Since flow cytometry is a personnel and time-intensive diagnostic tool, automated stem cell enumeration may provide a promising alternative. Hence, this study aimed to compare automated hematopoietic progenitor enumeration carried out on a Sysmex XN-20 module compared with conventional flow cytometric measurements. METHODS: One hundred forty-three blood samples from 41 patients were included in this study. Correlation between the two methods was calculated over all samples, depending on leukocyte count and diagnosis. RESULTS: Overall, we found a high degree of correlation (r = 0.884). Furthermore, correlation was not impaired by elevated leukocyte counts (>10 000/µL, r = 0.860 vs <10 000/µL, r = 0.849; >20 000/µL, r = 0.843 vs <20 000/µL, r = 0.875). However, correlation was significantly impaired in patients with multiple myeloma (multiple myeloma r = 0.840 vs nonmyeloma r = 0.934). SUMMARY: Stem cell measurement carried out on the Sysmex XN-20 module provides a significant correlation with flow cytometry and might be implemented in clinical practice. In clinical decision-making, there was discrepancy of under 15% of cases. In multiple myeloma patients, XN-20 should be used with caution.


Assuntos
Antígenos CD34 , Citometria de Fluxo , Células-Tronco Hematopoéticas , Humanos , Citometria de Fluxo/métodos , Antígenos CD34/análise , Antígenos CD34/sangue , Células-Tronco Hematopoéticas/citologia , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Masculino , Feminino , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/instrumentação , Pessoa de Meia-Idade , Contagem de Leucócitos , Adulto
6.
BMC Med Inform Decis Mak ; 24(1): 118, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702739

RESUMO

BACKGROUND: Pneumonia poses a major global health challenge, necessitating accurate severity assessment tools. However, conventional scoring systems such as CURB-65 have inherent limitations. Machine learning (ML) offers a promising approach for prediction. We previously introduced the Blood Culture Prediction Index (BCPI) model, leveraging solely on complete blood count (CBC) and differential leukocyte count (DC), demonstrating its effectiveness in predicting bacteremia. Nevertheless, its potential in assessing pneumonia remains unexplored. Therefore, this study aims to compare the effectiveness of BCPI and CURB-65 in assessing pneumonia severity in an emergency department (ED) setting and develop an integrated ML model to enhance efficiency. METHODS: This retrospective study was conducted at a 3400-bed tertiary medical center in Taiwan. Data from 9,352 patients with pneumonia in the ED between 2019 and 2021 were analyzed in this study. We utilized the BCPI model, which was trained on CBC/DC data, and computed CURB-65 scores for each patient to compare their prognosis prediction capabilities. Subsequently, we developed a novel Cox regression model to predict in-hospital mortality, integrating the BCPI model and CURB-65 scores, aiming to assess whether this integration enhances predictive performance. RESULTS: The predictive performance of the BCPI model and CURB-65 score for the 30-day mortality rate in ED patients and the in-hospital mortality rate among admitted patients was comparable across all risk categories. However, the Cox regression model demonstrated an improved area under the ROC curve (AUC) of 0.713 than that of CURB-65 (0.668) for in-hospital mortality (p<0.001). In the lowest risk group (CURB-65=0), the Cox regression model outperformed CURB-65, with a significantly lower mortality rate (2.9% vs. 7.7%, p<0.001). CONCLUSIONS: The BCPI model, constructed using CBC/DC data and ML techniques, performs comparably to the widely utilized CURB-65 in predicting outcomes for patients with pneumonia in the ED. Furthermore, by integrating the CURB-65 score and BCPI model into a Cox regression model, we demonstrated improved prediction capabilities, particularly for low-risk patients. Given its simple parameters and easy training process, the Cox regression model may be a more effective prediction tool for classifying patients with pneumonia in the emergency room.


Assuntos
Serviço Hospitalar de Emergência , Aprendizado de Máquina , Pneumonia , Índice de Gravidade de Doença , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Pneumonia/diagnóstico , Prognóstico , Contagem de Leucócitos , Taiwan , Contagem de Células Sanguíneas , Mortalidade Hospitalar , Idoso de 80 Anos ou mais , Adulto
7.
Clin Lab ; 70(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38623664

RESUMO

BACKGROUND: Despite the advanced laboratory technologies available today, blood culture is the gold standard method in the diagnosis of bloodstream infections. Automated blood culture devices give blood culture results for laboratories approximately in 2 - 3 days up to 7 days. Moreover, some microorganisms like nonreproducible bacteria, fungi or viruses cannot be produced in culture. Among all samples taken for blood culture on suspicion of infection approximately 10% are determined as positive whereas the false positive rate due to contamination is 5%. Especially in life-threatening severe conditions such as sepsis early diagnosis and prompt treatment are crucial. Based on this the aim of this study is to investigate complete blood count parameters as potential early markers in Escherichia coli, Staphylococcus aureus and Candida albicans bloodstream infections using an ex vivo whole blood model. METHODS: Blood samples collected from healthy donors (n = 10) were treated with suspensions containing a certain concentration of microorganisms (107 CFU/mL for both E. coli ATCC 25922 and S. aureus ATCC 29213, 106 CFU/mL for C. albicans ATCC 14053). After bacteremia and candidemia were induced, complete blood count parameters were analyzed hourly in the samples until the end of the 4th hour with a Mindray BC-6800 hematology analyzer. Statistical analysis was performed by Tukey-Kramer post-hoc multiple comparison test and statistical significance was accepted as p < 0.05. RESULTS: When platelet derived parameter baseline values were compared to hourly values in E. coli and S. aureus induced whole blood samples, it was found that the decrease in PLT, P-LCC and the increase in IPF% was significant from the first hour whereas the increase in IMG% was found to be significant only from the 3rd hour onward. In the experiments with C. albicans, it was observed that the increase in IPF% and IMG% was significant from the 2nd and 3rd hour onward, respectively. There was no relationship between MPV, P-LCR, and NLR baseline and hourly results in any microorganism induced model. CONCLUSIONS: IPF% can guide clinicians in the early diagnosis and management of treatment of infections caused by S. aureus, E. coli, and C. albicans.


Assuntos
Candidemia , Candidíase , Humanos , Escherichia coli , Staphylococcus aureus , Candida albicans , Candidíase/diagnóstico , Candidíase/microbiologia , Candidemia/microbiologia , Contagem de Células Sanguíneas
8.
BMC Res Notes ; 17(1): 99, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38566261

RESUMO

BACKGROUND: A complete blood count (CBC) analysis is one of the most common conventional blood tests that physicians frequently prescribe. THE OBJECTIVE: of this study was to determine the reference intervals (RIs) of CBC parameters in the population of healthy adults living in the western Sudan region. METHODS: A cross-sectional study of healthy people residing in the western area of Sudan was carried out. We assessed the CBC RIs in samples taken from 153 individuals using an automated haematology analyser (Sysmex KX-21) and a modified Box-Cox transformation procedure to transform the data into a Gaussian distribution after eliminating outliers using the Dixon method. IBM SPSS Statistics version 25 was used to analyse the data, and t tests were employed to examine variations in the mean CBC parameters according to sex and age. P was considered significant at ≤ 0.05. RESULTS: Beyond all the other measured values, the only CBC parameters that significantly differed between the sexes were haemoglobin (HGB) and white blood cell (WBC) counts. Women were found to experience more WBC counts than men did. However, they have less HGB RIs.The male participants in our study exhibited lower WBC count RIs, a significantly lower limit, and a greater upper limit of platelet RIs than did the individuals from other nations. CONCLUSIONS: Compared with males, females had higher platelet and WBC counts and lower HGB.


Assuntos
Testes Hematológicos , Hemoglobinas , Adulto , Humanos , Masculino , Feminino , Estudos Transversais , Valores de Referência , Contagem de Células Sanguíneas , Contagem de Leucócitos
9.
Eur Rev Med Pharmacol Sci ; 28(6): 2207-2216, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38567584

RESUMO

OBJECTIVE: We investigated the associations between osteoporosis (OP) and systemic immune inflammation index (SII), neutrophil-to-lymphocyte ratio (NLR), monocyte-to-lymphocyte ratio (MLR), and platelet-to-lymphocyte ratio (PLR) in postmenopausal women. PATIENTS AND METHODS: This retrospective study included 966 postmenopausal women. Logistic regression and receiver operating characteristic curve (ROC) analyses were applied to explore the relationships between SII, NLR, MLR, and PLR with the bone mineral density (BMD) and risk of OP. RESULTS: Logistic regression analyses showed that SII, PLR, NLR, and MLR had independent negative associations with the OP risk. The ROC curve analysis showed that SII, NLR, and MLR predicted a low BMD, with NLR having the highest predictive value (area under the curve = 0.624). SII > 504.09, PLR > 131.87, NLR > 2.02, and MLR > 0.12 correlated with a particularly high OP risk. CONCLUSIONS: High levels of SII, PLR, NLR, and MLR were associated with a high OP risk. In particular, NLR > 2.02 strongly predicted the risk of OP, thereby representing a valuable and convenient inflammatory marker of the OP risk.


Assuntos
Linfócitos , Pós-Menopausa , Humanos , Feminino , Estudos Retrospectivos , Contagem de Células Sanguíneas , Neutrófilos , Inflamação
10.
Malar J ; 23(1): 126, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38685081

RESUMO

INTRODUCTION: Introduction: Malaria continues to be the leading cause of hospitalization and death in Angola, a country in sub- Saharan Africa. In 2023, in the first quarter, 2,744,682 cases were registered, and of these 2,673 patients died due to malaria disease. Previous studies have shown that the ABO blood group can affect the progression of malaria to severe conditions after P. falciparum infection, while the sickle cell gene offers relative protection. OBJECTIVE: We investigated changes in the blood count according to blood groups (ABO/Rh) and sickle cell trait in patients with malaria in Luanda, capital of Angola. METHODOLOGY: This was a longitudinal, prospective and observational study with 198 patients hospitalized for malaria. RESULTS: Of the 198 patients studied, 13(6.6%) were ABRh(+), 4(2.0%) were ARh(-), 49(24.7%) were ARh(+), 42(21, 2%) were BRh (+), 5(2.5%) were ORh(-) and 85(42.9%) were ORh(+). For sickle cell trait, 145(73.2%) were AA, 37(18.7%) were AS and 16(8.1%) were SS. No statistical relationship was observed between age group, sex, parasitemia, clinical picture, hematocrit, MCV, HCM, MCHC, leukocytes, NEUT, LINF and PTL values with blood groups (p<0.05), but there was a relationship between values of hemoglobin and ABO/Rh blood groups (p>0.05). There was no relationship between age, parasitemia, clinical condition, MCV, HCM and MCHC values, leukocytes, NEUT and LINF with sickle cell trait (p<0.05), but there was a relationship between sex, hemoglobin and PTL and sickle cell values. sickle cell trait (p>0.05). CONCLUSION: It is imperative to differentiate patients with malaria based on blood groups and sickle cell trait, taking into account mainly the blood count parameters that demonstrate that there are patients who, depending on blood group or sickle cell trait, may react weakly to malaria infection regardless of the degree of parasitemia and medical prognosis.


Assuntos
Traço Falciforme , Humanos , Traço Falciforme/sangue , Masculino , Feminino , Estudos Prospectivos , Adulto , Criança , Adolescente , Pré-Escolar , Adulto Jovem , Estudos Longitudinais , Angola , Pessoa de Meia-Idade , Sistema ABO de Grupos Sanguíneos , Contagem de Células Sanguíneas/estatística & dados numéricos , Malária Falciparum/sangue , Sistema do Grupo Sanguíneo Rh-Hr , Lactente , Idoso
11.
Am J Trop Med Hyg ; 110(5): 1021-1028, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38531104

RESUMO

The interpretation of a laboratory test result requires an appropriate reference range established in healthy subjects, and normal ranges may vary by factors such as geographic region, sex, and age. We examined hematological and clinical chemistry parameters in healthy residents at two rural vaccine trial sites: Bancoumana and Doneguebougou in Mali, West Africa. During screening of clinical studies in 2018 and 2019, peripheral blood samples from 1,192 apparently healthy individuals age 6 months to 82 years were analyzed at a laboratory accredited by the College of American Pathologists for a complete blood count, and creatinine and/or alanine aminotransferase levels. Based on manufacturers' reference range values, which are currently used in Malian clinical laboratories, abnormal values were common in this healthy population. In fact, 30.4% of adult participants had abnormal neutrophil levels and 19.8% had abnormal hemoglobin levels. Differences by sex were observed in those who were older, but not in those younger than 10 years, for several parameters, including hemoglobin, platelet, and absolute neutrophil counts in hematology, and creatinine in biochemistry. The site-specific reference intervals we report can be used in malaria vaccine clinical trials and other interventional studies, as well as in routine clinical care, to identify abnormalities in hematological and biochemical parameters among healthy Malian trial participants.


Assuntos
População Rural , Humanos , Mali/epidemiologia , Masculino , Feminino , Adolescente , Adulto , Criança , Pré-Escolar , Valores de Referência , Pessoa de Meia-Idade , Lactente , População Rural/estatística & dados numéricos , Adulto Jovem , Idoso , Idoso de 80 Anos ou mais , Fatores Etários , Fatores Sexuais , Hemoglobinas/análise , Creatinina/sangue , Laboratórios Clínicos , Contagem de Células Sanguíneas
12.
Biol Open ; 13(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38385271

RESUMO

Although mitochondrial respiration is believed to explain a substantial part of the variation in resting metabolic rate (RMR), few studies have empirically studied the relationship between organismal and cellular metabolism. We therefore investigated the relationship between RMR and mitochondrial respiration of permeabilized blood cells in wild great tits (Parus major L.). We also studied the correlation between mitochondrial respiration traits and blood cell count, as normalizing mitochondrial respiration by the cell count is a method commonly used to study blood metabolism. In contrast to previous studies, our results show that there was no relationship between RMR and mitochondrial respiration in intact blood cells (i.e. with the ROUTINE respiration). However, when cells were permeabilized and interrelation re-assessed under saturating substrate availability, we found that RMR was positively related to phosphorylating respiration rates through complexes I and II (i.e. OXPHOS respiration) and to the mitochondrial efficiency to produce energy (i.e. net phosphorylation efficiency), though variation explained by the models was low (i.e. linear model: R2=0.14 to 0.21). However, unlike studies in mammals, LEAK respiration without [i.e. L(n)] and with [i.e. L(Omy)] adenylates was not significantly related to RMR. These results suggest that phosphorylating respiration in blood cells can potentially be used to predict RMR in wild birds, but that this relationship may have to be addressed in standardized conditions (permeabilized cells) and that the prediction risks being imprecise. We also showed that, in our conditions, there was no relationship between any mitochondrial respiration trait and blood cell count. Hence, we caution against normalising respiration rates using this parameter as is sometimes done. Future work should address the functional explanations for the observed relationships, and determine why these appear labile across space, time, taxon, and physiological state.


Assuntos
Metabolismo Basal , Metabolismo Energético , Animais , Metabolismo Basal/fisiologia , Mitocôndrias , Respiração , Contagem de Células Sanguíneas , Mamíferos
13.
J Clin Lab Anal ; 38(4): e25017, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38396348

RESUMO

BACKGROUND: Three-part differential (3PD) haematology analysers offer a quick, easy-to-use and economical way to acquire important information about a patient's physiology. In this study, we evaluated a new 3PD analyser, the Sysmex XQ-320, investigated its comparability with its predecessor (Sysmex XP-300) and the five-part differential analyser Sysmex XN-9000, and explored its flagging potential. METHODS: Analytical performance studies were conducted for repeatability, within-laboratory precision, between-day precision, carry-over and linearity with fresh blood and QC material. Method comparison was performed in 493 samples comparing XQ-320 with XP-300, using the XN-9000 as the gold standard. RESULTS: The XQ-320 excelled manufacturer's specifications in the analytical performance studies, except for MXD in within-laboratory and between-day precisions using the QC material level 1. The XQ-320 showed correlation values greater than 0.94 with XN-9000 for the majority of the 20 reportable parameters (MXD# 0.891, MXD% 0.898 and MCHC 0.849). Improvements over the XP-300 were observed in WBC in the leucocytopenic range (bias -0.038 vs. -0.097) and PLT (bias 2.568 vs. -7.877, intercept 3.880 vs. -8.845). Concordance between XQ-320 and XP-300 was 91.9% for the WBC histogram abnormal distribution flag and 95.3% for the PLT flag. Patterns of increased neutrophils and decreased mixed cells on the XQ-320 were observed in samples that raised a flag on XN-9000. CONCLUSION: The XQ-320 showed excellent analytical performance, and very good to excellent correlation with XN-9000 with improvements over XP-300. Flagging combined with parameter patterns identified additional suspected abnormal samples, thus making the XQ-320 an excellent solution for laboratories utilising 3PD analysers.


Assuntos
Hematologia , Humanos , Laboratórios , Nonoxinol , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes
14.
Int J Radiat Biol ; 100(4): 565-572, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38306486

RESUMO

PURPOSE: In the aftermath of a nuclear disaster or accident, survivors will suffer from radiation-induced normal tissue damage. Recovery after radiation exposure is dictated by several factors, one of which is degree of shielding at time of exposure. This study aims to characterize the short and late term changes in kinetics and magnitude of pancytopenia and blood chemistry in a model of heterogeneous radiation exposure, or partial body irradiation (PBI), compared to whole body irradiation (WBI). MATERIALS AND METHODS: Male C57BL/6 mice, 8-10 weeks of age, were WBI at 6 different doses (6, 6.1. 6.15, 6.2, 6.5, and 7.5 Gy) to establish the LD50. To determine the effect of shielding on blood cell counts and chemistry, animals were either WBI at 6 Gy (LD2230) or 6 Gy PBI with one leg shielding (LD030). Complete blood counts and chemistry were measured at 1, 5-, 10-, 20-, 30- and 120-days post-irradiation. RESULTS AND CONCLUSIONS: Irradiated animals had significant depletion of white blood cells, red blood cells and platelets up to 10 days post-irradiation. Separation between PBI and WBI were observed at 10- and 20-days post-irradiation at which point PBI animals showed sign of recovery while overall cell count remains depleted in WBI animals up to 30 days post-irradiation. In addition, significant changes were found in parameters indicative of hematopoietic injury including hemoglobin count, hematocrit count and white blood cell population. Significant changes were observed in kidney function with changes to blood urea nitrogen and calcium concentration at 5-days post-irradiation. At 10-days post-irradiation. liver function changes differentiated WBI from PBI animals. Long-term, irradiated animal's chemistry values and many blood counts were not significantly different from Sham. In conclusion, partial shielding ensured complete survival and demonstrated a different recovery kinetics of blood and chemistry parameters after irradiation compared to survivors of whole body irradiation and no single hemopoietic parameter was able to consistently differentiate irradiated from Sham animals. This seems to indicate that there is no single robust hemopoietic parameter to differentiate those exposed from those who were not due to the inherent variability in individual responses. Furthermore, there were no significant long-term effects on these blood parameters between survivors of WBI and PBI except that shielding accelerated recovery.


Assuntos
Leucócitos , Exposição à Radiação , Camundongos , Masculino , Animais , Camundongos Endogâmicos C57BL , Contagem de Células Sanguíneas , Doses de Radiação , Irradiação Corporal Total/efeitos adversos
15.
Vet Clin Pathol ; 53(1): 74-79, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38320962

RESUMO

BACKGROUND: Enzootic pneumonia is an important disease complex associated with insufficient colostrum intake after birth, adverse environmental conditions, and stress. Vitamin D deficiency may be an important predisposing factor for this disease. OBJECTIVE: This study aimed to investigate in calves with enzootic pneumonia. METHODS: A total of 30 calves, aged 3-5 months, under the same care and feeding conditions were used. Groups were formed according to Clinical Respiratory Scoring as the group with mild/moderate enzootic pneumonia (n = 10), the group with severe enzootic pneumonia (n = 10), and the healthy control group (n = 10) without any disease. Blood samples were collected from the jugular vein of animals in all groups on Day 0; a complete blood count was performed, and serum vitamin D levels were measured using the Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) method. RESULTS: Although no statistical differences were observed in total leukocyte, lymphocyte, eosinophil, basophil, hemoglobin, and hematocrit levels between groups, statistically significant differences in blood neutrophil, monocyte, and erythrocyte counts were found between the groups. Monocyte counts were statistically decreased in the mild/moderate group compared with the control group. Neutrophil counts were significantly higher in the mild/moderate and severe groups than in the control group. Erythrocyte counts were increased in the mild/moderate and severe groups compared with the control group. Vitamin D concentrations were statistically lower in the mild/moderate and severe groups than in the control group. However, no statistical differences in Vitamin D concentrations were observed between the mild/moderate and severe groups. There was a negative and significant correlation between erythrocyte counts and vitamin D concentrations (r = -0.64, P < .0001). While erythrocyte counts increased in the severe group compared with the mild/moderate group, vitamin D concentrations decreased. Also, a negative and significant correlation was observed between platelet counts and vitamin D concentrations (r = -0.74, P < .0001). CONCLUSIONS: The results of this study determined that serum vitamin D concentrations in calves with pneumonia were lower than those in healthy calves. Detailed studies on the etiologic and prognostic importance of low vitamin D levels in calves with enzootic pneumonia may provide valuable data for prevention and treatment.


Assuntos
Doenças dos Bovinos , Pneumonia , Animais , Bovinos , Colecalciferol , Cromatografia Líquida/veterinária , Espectrometria de Massas em Tandem/veterinária , Calcifediol , Vitamina D , Contagem de Células Sanguíneas/veterinária , Pneumonia/veterinária
16.
Vet Clin Pathol ; 53(1): 57-62, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38395432

RESUMO

BACKGROUND: Although widely used, the ADVIA 120 hematology analyzer has not been previously validated for determining the differential leukocyte count in goats. OBJECTIVES: The aim of this study was to compare the differential leukocyte counts provided by the ADVIA 120 (A-diff) and the manual method (M-Diff) in goats. METHODS: EDTA blood samples that were analyzed within 4 h of collection were used in the study. The following exclusion criteria were applied: inappropriately filled tubes or tubes containing clots, erroneous ADVIA peroxidase cytograms, and blood smears of poor quality. The A-Diff was compared with the M-Diff performed by two independent observers on 200 leukocytes. RESULTS: Forty samples were included after previously excluding eight samples. The correlation between the A-Diff and M-Diff was very strong for eosinophils (r = .870, p < .001) and strong for lymphocytes (r = .796, p < .001) and neutrophils (r = .730, p < .001), while no significant correlation was observed for monocytes (r = .026, p = .872). The Passing-Bablok regression analyses revealed statistically significant constant errors for neutrophils (5.83%; 95% confidence interval [CI]: 0.41%, 12.18%) and eosinophils (1.89%; 95% CI: 1.17%, 2.71%). Bland-Altman analyses showed a statistically significant negative bias for lymphocytes (-5.0%) and a statistically significant positive bias for eosinophils (2.2%). The very low basophil percentages precluded a meaningful method comparison. CONCLUSIONS: The ADVIA 120 overall demonstrated good performance for the differential WBC count in goats under the conditions of this study. Therefore, it can be considered suitable for routine hematologic screening in goats. Nonetheless, it should be emphasized that any abnormal result should be confirmed with a blood smear evaluation.


Assuntos
Cabras , Leucócitos , Animais , Reprodutibilidade dos Testes , Contagem de Leucócitos/veterinária , Eosinófilos , Contagem de Células Sanguíneas/veterinária
17.
Clin Appl Thromb Hemost ; 30: 10760296241227212, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38348584

RESUMO

Pulmonary embolism (PE) is an important cause of sudden death and is difficult to diagnose. Therefore unnecessary radiological investigations are often resorted to. Although some inflammatory parameters in the hemogram have been found to play a role in the diagnosis of PE, many parameters have not been adequately investigated. We aimed to evaluate potential inflammatory parameters in hemogram in the diagnosis of PE and to determine the parameters with the highest diagnostic value. This single-center, retrospective study was performed by evaluating 114 cases with suspected PE admitted to the emergency department between January 2017 and June 2022. Among 114 cases, 62 cases with a definitive diagnosis of PE by pulmonary computed tomography angiography served as the PE group and 52 cases without PE served as the control group. Admission hemogram parameters of both groups were recorded. Potential chronic diseases and acute conditions affecting hemogram were excluded from the study. In the multivariate model; immature granulocyte (IG), neutrophil/lymphocyte ratio (NLR), monocyte % and platelet large cell ratio (P-LCR) were found to be significantly and independently effective in differentiating cases with and without PE (P˂.05). Our findings suggest that high IG, high NLR, high monocyte %, and low P-LCR values have diagnostic value in cases with suspected PE. However the usability of IGs in the diagnosis of PE is a new finding. Hemogram is cheap, easily accessible, and potential inflammatory biomarkers in hemograms may increase physicians' awareness in the diagnosis of PE.


Assuntos
Embolia Pulmonar , Humanos , Estudos Retrospectivos , Contagem de Células Sanguíneas , Embolia Pulmonar/diagnóstico , Neutrófilos , Linfócitos
18.
Res Vet Sci ; 169: 105164, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38324973

RESUMO

Mediterranean area represents the main habitat of Testudo hermanni. Clinical signs of disease of these tortoises are non-specific, making the hematology results crucial in revealing underlying pathological conditions. However, accurate automated identification of blood cell populations is hampered by the presence of nucleated erythrocytes (NRBC) and thrombocytes (Thr), necessitating manual methods such as counting chambers. The aim of the study was to assess the performance of the novel automated hematology analyzer Sysmex XN-1000 V, which includes a a specific channel (WNR) for counting NRBC, in accurately identify and quantify the different blood cell populations of Testudo hermanni. Additionally, its agreement with manual counts was evaluated. Fifty heparinized blood samples were initially counted using the Neubauer improved chamber and then analysed twice with Sysmex XN-1000 V. Thirteen out of 50 samples were instrumentally counted again after 48 h to assess the inter-assay precision. All WNR scattergrams were re-analysed using an ad hoc gate panel to differentiate two populations: NRBCs (weak fluorescence signal) and WBC + Thr (high fluorescence signal). Sysmex XN-1000 V demonstrated optimal intra- and inter-assay precision for NRBCs (CV 0.98% ± 1.96; 1.31% ± 2.98) and moderate precision for WBC + Thr (CV 9.24% ± 16.61; 12.69% ± 10.35). No proportional nor constant errors were observed between the methods for both the populations. The instrumental NRBC counts were consistently slightly lower, while WBC + Thr counts were slightly higher compared to manual counts. These findings suggest that Sysmex XN-1000 V can be used for analyzing cell populations in heparinized blood of Testudo hermanni. However, specific instrumental reference intervals are suggested.


Assuntos
Hematologia , Tartarugas , Animais , Leucócitos , Eritroblastos , Contagem de Células/veterinária , Reprodutibilidade dos Testes , Contagem de Leucócitos/veterinária , Contagem de Células Sanguíneas/veterinária
19.
Res Vet Sci ; 169: 105172, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38340379

RESUMO

The establishment of hematological reference intervals (RIs) is an important tool to assess the health status of animals and to evaluate the impact of diseases at individual and population levels. Nowadays, specific RIs of hematological parameters in newborn dromedary camel calves at birth and during the first week after birth, are lacking. Therefore, RIs for the hematological variables from a complete blood cell count were established in 47 healthy newborn dromedary calves (18 females and 29 males). Blood samples were collected within 2 h after birth (d0), at 24 h (d1), at 3 (d3) and 7 days (d7) after birth, and analyzed within 24 h. The RIs were described based on the 95% confidence interval, and possible differences among mean values due to age (sampling time) and sex were investigated. Statistical analysis showed that age affected all the hematological variables except MCV, MCH, and MCHC, indicating that the adaptational process to the extrauterine life continues for several days after birth; sex affected most of the hematological variables, with higher RBC and PLT count, HGB, PCV, neutrophil population and neutrophil:lymphocyte ratio at d7 in females compared to males. These findings suggest possible sex-based differences in the physiological maturation mechanisms and deserves further investigations. To the best of the authors' knowledge, this is the first report of hematological RIs for newborn dromedary calves at birth up to 7 days of age; the RIs registered in the present study in newborns differ from those reported in adult dromedaries in literature, thus confirming the need for the adoption of separated reference ranges according to age also in the dromedary camel, as previously reported for other species.


Assuntos
Camelus , Hematologia , Masculino , Feminino , Animais , Contagem de Células Sanguíneas/veterinária , Neutrófilos , Valores de Referência
20.
Clin Lab ; 70(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345977

RESUMO

BACKGROUND: The benchtop ADVIA 560 AL hematology analyzer (Siemens Healthineers Tarrytown, NY, USA) offers a small footprint and ease of operation making it suitable for satellite laboratories and intensive care units. A verification study of this analyzer was performed. METHODS: Between- and intra-run precision, carry-over, linearity, and throughput were evaluated on the ADVIA 560 AL. Accuracy was assessed on 94 patient samples by comparing the results obtained on the ADVIA 560 AL to the results on the reference Sysmex XN1000 analyzer (Sysmex Corporation, Kobe, Japan). RESULTS: The ADVIA 560 AL showed acceptable imprecision on control material and minimal bias in comparison to the XN 1000 on patient samples with a throughput of 60 samples per hour. The percentage carryover was not significant and the linearity was within acceptable limits. CONCLUSIONS: The ADVIA 560 AL bench-top analyzer is suitable for acute care centers and satellite laboratories owing to its small footprint, ease of use, and reproducible and accurate results.


Assuntos
Hematologia , Humanos , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes , Hematologia/métodos , Laboratórios , Japão , Contagem de Leucócitos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA