Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 896
Filtrar
1.
Eur J Endocrinol ; 190(5): 401-408, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38652605

RESUMO

CONTEXT: Reliable estradiol (E2) reference intervals (RIs) are crucial in pediatric endocrinology. OBJECTIVES: This study aims to develop a sensitive ultra-performance liquid chromatographic tandem mass spectrometry (UPLC-MS/MS) method for E2 in serum, to establish graphically represented RI percentiles and annual RIs for both sexes, and to perform a systematic literature comparison. METHODS: First, a UPLC-MS/MS method for E2 was developed. Second, graphically represented RI percentiles and annual RIs covering 0-18 years were computed (cohort of healthy children [1181 girls and 543 boys]). Subsequently, RIs were compared with published data by systematic searches. RESULTS: Lower limit of quantification was 11 pmol/L, indicating high sensitivity. Estradiol first peaked during mini-puberty in both sexes (girls up to 192 pmol/L; boys up to 225 pmol/L). As could be expected, girls showed higher pubertal E2 (up to 638 pmol/L). However, boys' RIs (up to 259 pmol/L) overlapped considerably. We found 4 studies in the literature that also used LC-MS/MS to determine E2 and published RIs for the complete pediatric age range. Reference intervals varied considerably. Pre-pubertal and pubertal phases were present in all studies. Higher E2 during the time of mini-puberty in both sexes was documented in 3 studies including ours. CONCLUSIONS: Variability of RIs for E2 between studies illustrates the importance of laboratory-specific RIs despite using a LC-MS/MS reference method. In boys, the striking E2 peak during mini-puberty as well as high pubertal E2 without phenotypic estrogenization in regular male puberty indicates that the role of E2 in children and, especially in boys, requires better functional understanding.


Assuntos
Estradiol , Puberdade , Espectrometria de Massas em Tandem , Humanos , Masculino , Espectrometria de Massas em Tandem/métodos , Criança , Estradiol/sangue , Feminino , Valores de Referência , Pré-Escolar , Adolescente , Lactente , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Puberdade/sangue , Puberdade/fisiologia , Recém-Nascido , Maturidade Sexual/fisiologia
2.
Clin Chem Lab Med ; 62(7): 1339-1351, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38515344

RESUMO

OBJECTIVES: A reference measurement procedure (RMP) using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was developed and validated with the aim of accurately measuring carbamazepine-10,11-epoxide concentrations in human serum and plasma. METHODS: To establish traceability to SI units, the absolute content of the reference material was determined using quantitative nuclear magnetic resonance (qNMR) spectroscopy. As sample preparation a protein precipitation protocol followed by a high dilution step was established. Chromatographic separation from carbamazepine and potential metabolites was achieved using a C18 stationary phase. Selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement were evaluated based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. RESULTS: The RMP demonstrated very good selectivity and specificity, showing no evidence of a matrix effect. This enabled accurate quantification of carbamazepine-epoxide in the concentration range of 0.0400-12.0 µg/mL. The intermediate precision was found to be less than 2.1 %, and the repeatability coefficient of variation (CV) ranged from 1.2 to 1.8 % across all concentration levels. Regarding accuracy, the relative mean bias varied from 1.4 to 2.5 % for native serum levels and from 1.4 to 3.5 % for Li-heparin plasma levels. The measurement uncertainty for single measurements ranged from 1.6 to 2.1 %. CONCLUSIONS: In this study, we introduce a new LC-MS/MS-based candidate RMP for accurately measuring carbamazepine-10,11-epoxide in human serum and plasma. This novel method offers a traceable and dependable platform, making it suitable for standardizing routine assays and assessing clinically relevant samples.


Assuntos
Carbamazepina , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Carbamazepina/sangue , Carbamazepina/análogos & derivados , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
3.
Clin Chem Lab Med ; 62(7): 1327-1338, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38549258

RESUMO

OBJECTIVES: Primidone is an anticonvulsive drug used in the treatment of epilepsy and essential tremor. It offers beneficial effects in controlling seizures, but its usage is also associated with possible side effects. To ensure optimal therapy, it is crucial to measure its concentration through accurate quantification methods. Therefore, our main goal was to develop and validate a new reference measurement procedure (RMP) for accurately measuring primidone levels in human serum and plasma. METHODS: In our study, we focused on the separation of primidone from both known and unknown interferences using a C18 column. To achieve accurate sample preparation, we developed a protocol involving protein precipitation followed by a high dilution step. The validation of the assay and determination of measurement uncertainty were carried out following guidelines from organizations such as the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the Expression of Uncertainty in Measurement. These rigorous validation processes ensure the reliability and accuracy of our method for quantifying primidone levels in human serum and plasma samples. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interference. It can be used to quantify primidone in the range of 0.150-30.0 µg/mL. Intermediate precision was less than 4.0 %, and repeatability CV ranged from 1.0 to 3.3 % across all concentration levels. The relative mean bias ranged from 0.1 to 3.9 % for native serum levels, and from -2.6 to 2.8 % for lithium-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment were 1.5-4.1 % and 0.9-1.0 %, respectively. CONCLUSIONS: In this study, we introduce an innovative LC-MS/MS-based candidate RMP specifically designed for primidone in human serum and plasma. Our RMP offers a traceable platform, facilitating the standardization of routine assays and enabling the evaluation of clinically relevant samples. With this novel approach, we aim to enhance the accuracy and reliability of primidone measurements, ultimately benefiting the field of clinical research and patient care.


Assuntos
Primidona , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Primidona/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Padrões de Referência , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Limite de Detecção , Anticonvulsivantes/sangue , Espectrometria de Massa com Cromatografia Líquida
4.
Clin Chem Lab Med ; 62(7): 1314-1326, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38407268

RESUMO

OBJECTIVES: Phenobarbital serves as an antiepileptic drug (AED) and finds application in the treatment of epilepsy either as monotherapy or adjunctive therapy. This drug exhibits various pharmacodynamic properties that account for its beneficial effects as well as potential side effects. Accurate measurement of its concentration is critical for optimizing AED therapy through appropriate dose adjustments. Therefore, our objective was to develop and validate a new reference measurement procedure (RMP) for the accurate quantification of phenobarbital levels in human serum and plasma. METHODS: A sample preparation protocol based on protein precipitation followed by a high dilution step was established in combination with a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method using a C8 column to separate target analytes from known and unknown interferences. Assay validation and determination of measurement uncertainty were performed based on current guidelines. Selectivity and Specificity were assessed using spiked serum and plasma samples; to investigate possible matrix effects (MEs) a post-column infusion experiment and a comparison of standard line slopes was performed. Precision and accuracy were determined within a multiday precision experiment. RESULTS: The RMP was shown to be highly selective and specific, with no evidence of matrix interferences. It can be used to quantify phenobarbital in the range of 1.92 to 72.0 µg/mL. Intermediate precision was less than 3.2 %, and repeatability coefficient of variation (CV) ranged from 1.3 to 2.0 % across all concentration levels. The relative mean bias ranged from -3.0 to -0.7 % for native serum levels, and from -2.8 to 0.8 % for Li-heparin plasma levels. The measurement uncertainties (k=1) for single measurements and target value assignment were 1.9 to 3.3 % and 0.9 to 1.6 %, respectively. CONCLUSIONS: A novel LC-MS/MS-based candidate RMP for the quantification of phenobarbital in human serum and plasma is presented which can be used for the standardization of routine assays and the evaluation of clinically relevant samples.


Assuntos
Fenobarbital , Espectrometria de Massas em Tandem , Humanos , Fenobarbital/sangue , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Anticonvulsivantes/sangue , Padrões de Referência , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Técnicas de Diluição do Indicador , Espectrometria de Massa com Cromatografia Líquida
5.
Clin Chem Lab Med ; 62(6): 1080-1091, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38205643

RESUMO

OBJECTIVES: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS). We assessed the agreement of androstenedione, DHEAS and testosterone LC-MS/MS measurements among nine European centers and explored benefits of calibration system unification. METHODS: Androgens were measured twice by laboratory-specific procedures in 78 patient samples and in EQA materials. Results were obtained by in-house and external calibration. Intra- and inter-laboratory performances were valued. RESULTS: Intra-laboratory CVs ranged between 4.2-13.2 % for androstenedione, 1.6-10.8 % for DHEAS, and 4.3-8.7 % and 2.6-7.1 % for female and male testosterone, respectively. Bias and trueness in EQA materials were within ±20 %. Median inter-laboratory CV with in-house vs. external calibration were 12.0 vs. 9.6 % for androstenedione (p<0.001), 7.2 vs. 4.9 % for DHEAS (p<0.001), 6.4 vs. 7.6 % for female testosterone (p<0.001) and 6.8 and 7.4 % for male testosterone (p=0.111). Median bias vs. all laboratory median with in-house and external calibration were -13.3 to 20.5 % and -4.9 to 18.7 % for androstenedione, -10.9 to 4.8 % and -3.4 to 3.5 % for DHEAS, -2.7 to 6.5 % and -11.3 to 6.6 % for testosterone in females, and -7.0 to 8.5 % and -7.5 to 11.8 % for testosterone in males, respectively. CONCLUSIONS: Methods showed high intra-laboratory precision but variable bias and trueness. Inter-laboratory agreement was remarkably good. Calibration system unification improved agreement in androstenedione and DHEAS, but not in testosterone measurements. Multiple components, such as commutability of calibrators and EQA materials and internal standard choices, likely contribute to inter-laboratory variability.


Assuntos
Androstenodiona , Sulfato de Desidroepiandrosterona , Espectrometria de Massas em Tandem , Testosterona , Androstenodiona/sangue , Androstenodiona/análise , Testosterona/sangue , Testosterona/análise , Testosterona/normas , Humanos , Espectrometria de Massas em Tandem/normas , Espectrometria de Massas em Tandem/métodos , Calibragem , Masculino , Feminino , Cromatografia Líquida/normas , Cromatografia Líquida/métodos , Sulfato de Desidroepiandrosterona/sangue , Sulfato de Desidroepiandrosterona/análise , Sulfato de Desidroepiandrosterona/normas , Pessoa de Meia-Idade , Espectrometria de Massa com Cromatografia Líquida
6.
Clin Chem Lab Med ; 62(7): 1288-1300, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38105272

RESUMO

OBJECTIVES: To describe and validate an isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) based reference measurement procedure (RMP) for zonisamide to accurately measure serum and plasma concentrations. METHODS: Quantitative nuclear magnetic resonance (qNMR) spectroscopy was employed to determine the absolute content of the reference material used in order to establish traceability to SI units. Separation of zonisamide from known or unknown interferences was performed on a C8 column. For sample preparation a protocol based on protein precipitation in combination with a high dilution step was established. Assay validation and determination of measurement uncertainty were performed based on guidelines from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. RESULTS: The RMP was proven to be highly selective and specific with no evidence of a matrix effect, allowing for quantification of zonisamide within the range of 1.50-60.0 µg/mL. Intermediate precision was <1.4 % and repeatability CV ranged from 0.7 to 1.2 % over all concentration levels. The relative mean bias ranged from 0.0 to 0.8 % for native serum levels and from 0.2 to 2.0 % for Li-heparin plasma levels. The measurement uncertainties for single measurements and target value assignment ranged from 1.1 to 1.4 % and 0.8-1.0 %, respectively. CONCLUSIONS: We present a novel LC-MS/MS-based candidate RMP for zonisamide in human serum and plasma which provides a traceable and reliable platform for the standardization of routine assays and evaluation of clinically relevant samples.


Assuntos
Isoxazóis , Espectrometria de Massas em Tandem , Zonisamida , Humanos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Zonisamida/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Isoxazóis/sangue , Padrões de Referência , Técnicas de Diluição do Indicador , Análise Química do Sangue/métodos , Análise Química do Sangue/normas , Espectrometria de Massa com Cromatografia Líquida
7.
Anal Bioanal Chem ; 414(5): 1949-1962, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34981149

RESUMO

Recently, numerous diagnostic approaches from different disciplines have been developed for SARS-CoV-2 diagnosis to monitor and control the COVID-19 pandemic. These include MS-based assays, which provide analytical information on viral proteins. However, their sensitivity is limited, estimated to be 5 × 104 PFU/ml in clinical samples. Here, we present a reliable, specific, and rapid method for the identification of SARS-CoV-2 from nasopharyngeal (NP) specimens, which combines virus capture followed by LC-MS/MS(MRM) analysis of unique peptide markers. The capture of SARS-CoV-2 from the challenging matrix, prior to its tryptic digestion, was accomplished by magnetic beads coated with polyclonal IgG-α-SARS-CoV-2 antibodies, enabling sample concentration while significantly reducing background noise interrupting with LC-MS analysis. A sensitive and specific LC-MS/MS(MRM) analysis method was developed for the identification of selected tryptic peptide markers. The combined assay, which resulted in S/N ratio enhancement, achieved an improved sensitivity of more than 10-fold compared with previously described MS methods. The assay was validated in 29 naive NP specimens, 19 samples were spiked with SARS-CoV-2 and 10 were used as negative controls. Finally, the assay was successfully applied to clinical NP samples (n = 26) pre-determined as either positive or negative by RT-qPCR. This work describes for the first time a combined approach for immuno-magnetic viral isolation coupled with MS analysis. This method is highly reliable, specific, and sensitive; thus, it may potentially serve as a complementary assay to RT-qPCR, the gold standard test. This methodology can be applied to other viruses as well.


Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Cromatografia Líquida/métodos , Separação Imunomagnética/métodos , SARS-CoV-2/genética , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Anticorpos Antivirais/química , Biomarcadores/química , COVID-19/imunologia , COVID-19/virologia , Teste para COVID-19/instrumentação , Teste para COVID-19/normas , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Humanos , Separação Imunomagnética/instrumentação , Separação Imunomagnética/normas , Nasofaringe/virologia , Peptídeos/química , Peptídeos/imunologia , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/normas
8.
Artigo em Inglês | MEDLINE | ID: mdl-35093854

RESUMO

In metabolomics, retention prediction methods have been developed based on the structural and physicochemical characteristics of analytes. Such methods employ regression models, harnessing machine learning algorithms mapping experimentally derived retention time (tR) analytes with various structural and physicochemical descriptors, known as Quantitative Structure Retention Relationships (QSRR) models. In the present study, QSRR models have been developed by applying four Machine Learning regression algorithms, i.e. Bayesian Ridge Regression (BRidgeR), Extreme Gradient Boosting Regression (XGBR) and Support Vector Regression (SVR) using both linear and non-linear kernels, all tested and compared for their retention prediction ability on experimentally derived and on publicly available chromatographic data, using Molecular Descriptors to describe the physical, chemical or structural properties of molecules. Various configurations of the available datasets, in terms of the highly-correlated features levels (defined as the maximum absolute value of the Pearson's correlation coefficient calculated between any pair of features) they contained, were analyzed in parallel. This is the first study, to the best of our knowledge, of the effect of collinearity on the performance of QSRR predictive models. In the vast majority of cases studied there was no statistically significant difference in the performance of the generated QSRR predictive models among the specified dataset configurations, indicative of the ability of the selected regression algorithms to effectively handle collinearity. In terms of the individual performance of the selected regression algorithms, no pattern was found where one algorithm (or class of algorithms) stood out significantly relative to the others among the study datasets.


Assuntos
Cromatografia Líquida/métodos , Aprendizado de Máquina , Compostos Orgânicos/química , Algoritmos , Teorema de Bayes , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Bases de Dados de Compostos Químicos , Modelos Lineares , Espectrometria de Massas , Metabolômica , Estrutura Molecular , Compostos Orgânicos/isolamento & purificação
9.
Biomed Chromatogr ; 36(1): e5242, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34519061

RESUMO

The reported method involves a novel workflow that eliminates the need for authentic reference standards for the quantitation of drug metabolites in biological samples using a single multi-isotopically labeled compound bearing both radio and stable isotopes. The resulting radio and stable bifunctionalized isotopolog (RADSTIL) of the parent drug is employed as a substrate for in vitro biotransformation to targeted RADSTILs of metabolites as calibrants. Inclusion of a radio label enables both radiometric and mass spectrometric detection. The addition of stable labels ensures the subsequent isotopic interference-free quantitation of unlabeled metabolites in preclinical and clinical samples. This affords a more accurate quantitation workflow compared with the current semi-quantitation method, which utilizes isotopic interfering radio isotopologs of metabolites alone as calibrants. The proof-of-concept is illustrated with (14 C,13 C2 )-acetaminophen where in vitro biotransformation produced (14 C,13 C2 )-sulfate and (14 C,13 C2 )-glucuronide calibrants. Absolute quantitation of the acetaminophen metabolites was then achieved by liquid chromatography coupled with radiometry and mass spectrometry. Quantitative data obtained by this method fell within 82-86% of the values from conventional LC-MS/MS method.


Assuntos
Cromatografia Líquida/normas , Isótopos , Espectrometria de Massas em Tandem/normas , Acetaminofen/sangue , Acetaminofen/química , Animais , Biotransformação , Calibragem , Cromatografia Líquida/métodos , Haplorrinos , Humanos , Isótopos/sangue , Isótopos/química , Masculino , Nêutrons , Radiometria , Ratos , Espectrometria de Massas em Tandem/métodos
10.
Nat Protoc ; 16(12): 5398-5425, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34716448

RESUMO

Many biological systems are composed of diverse single cells. This diversity necessitates functional and molecular single-cell analysis. Single-cell protein analysis has long relied on affinity reagents, but emerging mass-spectrometry methods (either label-free or multiplexed) have enabled quantifying >1,000 proteins per cell while simultaneously increasing the specificity of protein quantification. Here we describe the Single Cell ProtEomics (SCoPE2) protocol, which uses an isobaric carrier to enhance peptide sequence identification. Single cells are isolated by FACS or CellenONE into multiwell plates and lysed by Minimal ProteOmic sample Preparation (mPOP), and their peptides labeled by isobaric mass tags (TMT or TMTpro) for multiplexed analysis. SCoPE2 affords a cost-effective single-cell protein quantification that can be fully automated using widely available equipment and scaled to thousands of single cells. SCoPE2 uses inexpensive reagents and is applicable to any sample that can be processed to a single-cell suspension. The SCoPE2 workflow allows analyzing ~200 single cells per 24 h using only standard commercial equipment. We emphasize experimental steps and benchmarks required for achieving quantitative protein analysis.


Assuntos
Peptídeos/isolamento & purificação , Proteoma/isolamento & purificação , Proteômica/métodos , Análise de Célula Única/métodos , Animais , Benchmarking , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Células HeLa , Humanos , Indicadores e Reagentes/química , Camundongos , Oócitos/citologia , Oócitos/metabolismo , Peptídeos/química , Peptídeos/classificação , Cultura Primária de Células , Proteoma/química , Proteoma/classificação , Células RAW 264.7 , Análise de Célula Única/normas , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Células U937
11.
Biomed Chromatogr ; 35(12): e5217, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34405424

RESUMO

A sensitive and highly efficient LC-ESI-MS/MS method using a stable isotope-labeled internal standard (SIL IS) to detect meloxicam in human plasma was developed and validated. Sample preparation used only 50 µL human plasma with one-step methanol protein precipitation. A gradient mobile phase system was adopted for chromatographic separation on a Poroshell 120 SB-C18 column (2.1 × 50 mm, 2.7 µm). Positive ion pattern was chosen for quantification under multiple reaction monitoring. Ion pairs were [M + H]+ m/z 352.1 → 115.1 for meloxicam and [M + H]+ m/z 355.1 → 187.1 for meloxicam-d3 (SIL IS). Total run time was 4.0 min. Standard curve was linear over a concentration range from 8.00 to 1600 ng mL-1 . This method was fully validated to evaluate its performance, including specificity, carryover, sensitivity, linearity, accuracy, precision, recovery, matrix effects, stability, dilution reliability and incurred sample reanalysis, which provided a reliable basis for pharmacokinetic studies of meloxicam in 28 healthy Chinese volunteers. After a single-dose oral administration of 7.5 mg meloxicam, the main pharmacokinetic parameters were as follows: Cmax , 814.79 ± 201.37 ng mL-1 ; Tmax , 4.54 ± 1.42 h; AUC0-t , 24,572.04 ± 5766.93 ng·h mL-1 ; AUC0-∞ , 25,810.89 ± 6796.60 ng·h mL-1 and t1/2 , 21.11 ± 5.35 h.


Assuntos
Cromatografia Líquida/métodos , Meloxicam , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/normas , Humanos , Marcação por Isótopo , Limite de Detecção , Modelos Lineares , Masculino , Meloxicam/sangue , Meloxicam/farmacocinética , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/normas
12.
Toxins (Basel) ; 13(8)2021 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-34437457

RESUMO

Farm animals are frequently exposed to mycotoxins, which have many adverse effects on their health and become a significant food safety issue. Pigs are highly exposed and particularly susceptible to mycotoxins, which can cause many adverse effects. For the above reasons, an appropriate diagnostic tool is needed to monitor pig' exposure to mycotoxins. The most popular tool is feed analysis, which has some disadvantages, e.g., it does not include individual exposure. In recent years, the determination of biomarkers as a method to assess the exposure to mycotoxins by using concentrations of the parent compounds and/or metabolites in biological matrices is becoming more and more popular. This review provides a comprehensive overview of reported in vivo mycotoxin absorption, distribution, metabolism and excretion (ADME) and toxicokinetic studies on pigs. Biomarkers of exposure for aflatoxins, deoxynivalenol, ochratoxin A, fumonisins, T-2 toxin and zearalenone are described to select the most promising compound for analysis of porcine plasma, urine and faeces. Biomarkers occur in biological matrices at trace levels, so a very sensitive technique-tandem mass spectrometry-is commonly used for multiple biomarkers quantification. However, the sample preparation for multi-mycotoxin methods remains a challenge. Therefore, a summary of different biological samples preparation strategies is included in that paper.


Assuntos
Biomarcadores/sangue , Cromatografia Líquida de Alta Pressão/normas , Cromatografia Líquida/normas , Técnicas e Procedimentos Diagnósticos/normas , Micotoxinas/sangue , Micotoxinas/metabolismo , Espectrometria de Massas em Tandem/normas , Animais , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Guias como Assunto , Suínos , Espectrometria de Massas em Tandem/métodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-34218093

RESUMO

The accurate determination of the pharmacokinetics (PK) of a candidate drug molecule is critical in both drug discovery and development. Over the last 30 years, the sensitivity and selectivity of LC/MS has resulted in it being established as the technology of choice for these studies. However, unwanted chemical interactions between analyte(s) and the metal components in a chromatography system can result in poor peak shape and reduction in signal response, which can adversely affect the analysis of low concentrations of drugs and their metabolites in biological samples. This study evaluated the benefits of employing an inert hybrid surface technology (HST) applied to the metallic components in the LC flow path, column frits and column wall to mitigate these interactions. The results obtained were compared with that of an identical conventional LC for the bioanalysis of two steroid phosphate drugs (dexamethasone phosphate and hydrocortisone phosphate) and an epidermal growth factor receptor (EGFR) inhibitor (gefitinib) in human plasma. The results showed that for the two steroid phosphates, the peak width was reduced by 20%, peak tailing factors reduced by up to 30% and the assay sensitivity improved by factors of 7.5 and 10. This resulted in a significant improvement in the limit of detection. The new LC system also improved the reproducibility of peak integration for gefitinib, thereby reducing assay coefficients of variation (%CV) from greater than 10% to less than 5% at the lower limit of quantification.


Assuntos
Cromatografia Líquida/instrumentação , Metais/química , Preparações Farmacêuticas , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Descoberta de Drogas , Humanos , Limite de Detecção , Preparações Farmacêuticas/sangue , Preparações Farmacêuticas/química , Reprodutibilidade dos Testes , Propriedades de Superfície
14.
J Chromatogr A ; 1653: 462399, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34284262

RESUMO

Differences in elution strength between the sample solvent and the mobile phase usually give rise to undesirable effects on the chromatographic separation, which may range from slight broadening to severe peak deformation or even splitting. In the most extreme case, the retention factor of the analyte at the head of the column is so small at the time of injection that part of the analyte goes through the column with very little interaction with the stationary phase and hence elutes very close to the column dead time. This phenomenon is known as breakthrough. Usually, during breakthrough, the retained peak displays a wide array of deformations and it is not rare that multiple retained peaks appear for a given injected analyte. However, under certain conditions, it has been demonstrated that these deleterious effects could fully disappear, leaving only one breakthrough peak and one symmetrical peak on the chromatogram. This so-called "total breakthrough" phenomenon was recently highlighted in the specific context of the 2D-LC separation of peptides but has yet to be explained. In the present paper, we describe the results of a comprehensive study aiming to better understand and define the conditions of emergence of both breakthrough and total breakthrough phenomena in liquid chromatography. The effects of a broad range of parameters, including the nature of the solute, the retention mechanism, the injection and elution conditions, the column temperature, and the injected sample concentration on the occurrence of both phenomena were investigated. While breakthrough was found to occur for all studied compounds, it appears that the presence of positive charges on the molecule is a prerequisite for observing a total breakthrough phenomenon. Among all the parameters investigated in this work, only the injection conditions and the analyte retention were found to be impactful on the onset of both phenomena. This finding allowed us to suggest one necessary and sufficient condition, relying on the injection of critical volumes to observe each respective phenomenon. These critical volumes only depend on the column dead volume and the retention factor of the analyte in the injection solvent.


Assuntos
Cromatografia Líquida , Solventes , Cromatografia Líquida/normas , Peptídeos/química , Solventes/química
15.
Clin Biochem ; 97: 78-81, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34329621

RESUMO

In the field of laboratory medicine, proficiency testing is a vehicle used to improve the reliability of reported results. When proficiency tests are unavailable for a given analyte, an alternative approach is required to ensure adherence to the International Organization for Standardization (ISO) 15189:2012 standard. In this study, we report the results of a split-sample testing program performed as an alternative to a formal PT. This testing method was based on recommendations provided in the Clinical and Laboratory Standards Institute (CLSI) QMS24 guideline. Two different laboratories measured, in duplicate, the heparan sulfate concentration in five samples using ultra-performance liquid chromatography and tandem mass spectrometry. The data analysis to determine the criterion used for the comparability assessment between the two laboratories was based on Appendix E of the QMS24 guideline. Mean interlaboratory differences fell within the maximum allowable differences calculated from the application of the QMS24 guideline, indicating that the results obtained by the two laboratories were comparable across the concentrations tested. Application of the QMS24 split-sample testing procedure allows laboratories to objectively assess test results, thus providing the evidence needed to face an accreditation audit with confidence. However, due to the limitations of statistical analyses in small samples (participants and/or materials), laboratory specialists should assess whether the maximum allowable differences obtained are suitable for the intended use, and make adjustments if necessary.


Assuntos
Laboratórios Clínicos/normas , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Cromatografia Líquida/normas , Heparitina Sulfato/análise , Heparitina Sulfato/sangue , Humanos , Espectrometria de Massas em Tandem/normas
16.
J Chromatogr A ; 1650: 462247, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34087520

RESUMO

The adsorptive loss of acidic analytes in liquid chromatography was investigated using metal frits. Repetitive injections of acidic small molecules or an oligonucleotide were made on individual 2.1 or 4.6 mm i.d. column frits. Losses were observed for adenosine 5'-(α,ß-methylene) diphosphate, 2-pyridinol 1-oxide and the 25-mer phosphorothioate oligonucleotide Trecovirsen (GEM91) on stainless steel and titanium frits. Analyte adsorption was greatest at acidic pH due to the positive charge on the metal oxide surface. Analyte recovery increased when a series of injections was performed; this effect is known as sample conditioning. Nearly complete recovery was achieved when the metal adsorptive sites were saturated with the analyte. A similar effect was achieved by conditioning the frits with phosphoric, citric or etidronic acids, or their buffered solutions. These procedures can be utilized to mitigate analyte loss. However, the effect is temporary, as the conditioning agent is gradually removed by the running mobile phase. Metal frits modified with hybrid organic/inorganic surface technology were shown to mitigate analyte-to-metal surface interactions and improve recovery of acidic analytes. Quantitative recovery of a 15-35 mer oligodeoxythymidine mixture was achieved using column hardware modified with hybrid surface technology, without a need for column conditioning prior to analysis.


Assuntos
Cromatografia Líquida , Metais , Adsorção , Soluções Tampão , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Ácido Cítrico/química , Ácido Etidrônico/química , Indicadores e Reagentes , Metais/química , Ácidos Fosfóricos/química , Aço Inoxidável/química , Propriedades de Superfície , Titânio/química
17.
J Chromatogr A ; 1651: 462331, 2021 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-34153736

RESUMO

Modern analytical applications of liquid chromatography require more and more efficient columns. In this work, the possibility of utilizing particle size gradient in the chromatographic column was studied by a theoretical approach. In the course of our work three different scenarios of particle size gradients were considered with different shapes (linear, convex and concave). The evolution of bandwidth inside the column was plotted for each scenario. As a reference point, the bandwidth of the uniform column was used, which had the same pressure drop as the non-uniform column. According to our calculations, in isocratic elution mode, the non-uniform column does not offer any advantage compared to the uniform column, regardless the type of the particle size gradient. In gradient elution mode, however, extra band compression occurs was found. For negative particle size gradients, the final physical bandwidth was found to be approximately 1-4 % smaller than for uniform columns. This slight gain in efficiency in terms of bandwidth compression can be expanded to 5-8 % by the optimization of the limiting particle sizes. These optimized results are obtained when the final particle size is approximately 40% of the initial particle diameter.


Assuntos
Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Modelos Teóricos , Tamanho da Partícula
18.
J Chromatogr A ; 1650: 462258, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34058594

RESUMO

This article describes the use of a new prototype column hardware made with 1.5 mm internal diameter (i.d.) and demonstrates some benefits over the 1.0 mm i.d. micro-bore column. The performance of 2.1, 1.5 and 1.0 mm i.d. columns were systematically compared. With the 1.5 mm i.d. column, the loss of apparent column efficiency can be significantly reduced compared to 1.0 mm i.d. columns in both isocratic and gradient elution modes. In the end, the 1.5 mm i.d. column is almost comparable to 2.1 mm i.d. column from a peak broadening point of view. The advantages of the 1.5 mm i.d. hardware vs 2.1 mm i.d. narrow-bore columns are the lower sample and solvent consumption, and reduced frictional heating effects due to decreased operating flow rates.


Assuntos
Cromatografia Líquida , Cromatografia Líquida/economia , Cromatografia Líquida/instrumentação , Cromatografia Líquida/normas , Solventes
19.
AAPS J ; 23(3): 64, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33942188

RESUMO

In the absence of regulatory guidelines for the bioanalysis of new drug modalities, many of which contain multiple functional domains, bioanalytical strategies have been carefully designed to characterize the intact drug and each functional domain in terms of quantity, functionality, biotransformation, and immunogenicity. The present review focuses on the bioanalytical challenges and considerations for RNA-based drugs, bispecific antibodies and multi-domain protein therapeutics, prodrugs, gene and cell therapies, and fusion proteins. Methods ranging from the conventional ligand binding assays and liquid chromatography-mass spectrometry assays to quantitative polymerase chain reaction or flow cytometry often used for oligonucleotides and cell and gene therapies are discussed. Best practices for method selection and validation are proposed as well as a future perspective to address the bioanalytical needs of complex modalities.


Assuntos
Bioensaio/normas , Desenvolvimento de Medicamentos/normas , Guias como Assunto , Anticorpos Biespecíficos/análise , Anticorpos Biespecíficos/uso terapêutico , Bioensaio/métodos , Terapia Baseada em Transplante de Células e Tecidos , Cromatografia Líquida/normas , Desenvolvimento de Medicamentos/métodos , Citometria de Fluxo/normas , Terapia Genética , Espectrometria de Massas/normas , Oligonucleotídeos/análise , Oligonucleotídeos/uso terapêutico , Pró-Fármacos/análise , Pró-Fármacos/uso terapêutico , RNA/análise , RNA/uso terapêutico , Proteínas Recombinantes de Fusão/análise , Proteínas Recombinantes de Fusão/uso terapêutico
20.
Toxins (Basel) ; 13(4)2021 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-33808320

RESUMO

The development of incurred reference materials containing citrinin (CIT) and their successful application in a method validation study (MVS) in order to harmonize CIT determination in food and food supplements are demonstrated. CIT-contaminated materials made of red yeast rice (RYR), wheat flour, and Ginkgo biloba leaves (GBL), as well as food supplements made of red yeast rice (FS-RYR) and Ginkgo biloba leaves (FS-GBL), were manufactured in-house via fungal cultivation on collected raw materials. The homogeneity and stability from randomly selected containers were verified according to the ISO 13528. CIT was found to be homogenously distributed and stable in all contaminated materials, with no significant degradation during the timescale of the MVS when storage was performed up to +4 °C. Next, an MVS was organized with eighteen international laboratories using the provided standard operating procedure and 12 test materials, including three RYRs (blank, <50 µg/kg, <2000 µg/kg), two wheat flours (blank, <50 µg/kg), two GBL powders (blank, <50 µg/kg), three FS-RYRs (blank, <50 µg/kg, <2000 µg/kg), and two FS-GBLs (blank, <50 µg/kg). The results of seven CIT-incurred materials showed acceptable within-laboratory precision (RSDr) varying from 6.4% to 14.6% and between-laboratory precision (RSDR) varying from 10.2% to 37.3%. Evidenced by HorRat values < 2.0, the results of the collaborative trial demonstrated that the applied analytical method could be standardized. Furthermore, the appropriateness of producing CIT reference materials is an important step towards food and feed quality control systems and the organization of proficiency tests.


Assuntos
Produtos Biológicos/análise , Cromatografia Líquida/normas , Citrinina/análise , Suplementos Nutricionais/análise , Farinha/análise , Contaminação de Alimentos , Ginkgo biloba/química , Espectrometria de Massas em Tandem/normas , Calibragem , Humanos , Variações Dependentes do Observador , Folhas de Planta/química , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA