Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.627
Filtrar
1.
JMIR Public Health Surveill ; 10: e56283, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222341

RESUMO

BACKGROUND: Despite increasing awareness, silica dust-induced silicosis still contributes to the huge disease burden in China. Worryingly, recent silica dust exposure levels and silicosis risk in Chinese noncoal mines remain unclear. OBJECTIVE: We aimed to determine recent silica dust exposure levels and assess the risk of silicosis in Chinese noncoal mines. METHODS: Between May and December 2020, we conducted a retrospective cohort study on 3 noncoal mines and 1 public hospital to establish, using multivariable Cox regression analyses, prediction formulas of the silicosis cumulative hazard ratio (H) and incidence (I) and a cross-sectional study on 155 noncoal mines in 10 Chinese provinces to determine the prevalence of silica dust exposure (PDE), free silica content, and total dust and respirable dust concentrations. The qualitative risk of silicosis was assessed using the International Mining and Metals Commission's risk-rating table and the occupational hazard risk index; the quantitative risk was assessed using prediction formulas. RESULTS: Kaplan-Meier survival analysis revealed significant differences in the silicosis probability between silica dust-exposed male and female miners (log-rank test χ21=7.52, P=.01). A total of 126 noncoal mines, with 29,835 miners and 4623 dust samples, were included; 13,037 (43.7%) miners were exposed to silica dust, of which 12,952 (99.3%) were male. The median PDE, free silica content, total dust concentration, and respirable dust concentration were 61.6%, 27.6%, 1.30 mg/m3, and 0.58 mg/m3, respectively, indicating that miners in nonmetal, nonferrous metal, small, and open-pit mines suffer high-level exposure to silica dust. Comprehensive qualitative risk assessment showed noncoal miners had a medium risk of silicosis, and the risks caused by total silica dust and respirable silica dust exposure were high and medium, respectively. When predicting H and I over the next 10, 20, and 30 years, we assumed that the miner gender was male. Under exposure to current total silica dust concentrations, median I10, I20, and I30 would be 6.8%, 25.1%, and 49.9%, respectively. Under exposure to current respirable silica dust concentrations, median I10, I20, and I30 would be 6.8%, 27.7%, and 57.4%, respectively. These findings showed that miners in nonmetal, nonferrous metal, small, and open-pit mines have a higher I and higher qualitative silicosis risk. CONCLUSIONS: Chinese noncoal miners, especially those in nonmetal, nonferrous metal, small, and open-pit mines, still suffer high-level exposure to silica dust and a medium-level risk of silicosis. Data of both total silica dust and respirable silica dust are vital for occupational health risk assessment in order to devise effective control measures to reduce noncoal mine silica dust levels, improve miners' working environment, and reduce the risk of silicosis.


Assuntos
Poeira , Mineração , Exposição Ocupacional , Dióxido de Silício , Silicose , Humanos , Silicose/epidemiologia , Silicose/etiologia , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Exposição Ocupacional/estatística & dados numéricos , Dióxido de Silício/análise , Dióxido de Silício/efeitos adversos , Poeira/análise , Masculino , China/epidemiologia , Feminino , Medição de Risco/métodos , Estudos Retrospectivos , Mineração/estatística & dados numéricos , Adulto , Pessoa de Meia-Idade , Estudos Transversais , Estudos de Coortes
2.
PLoS One ; 19(8): e0306465, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39178295

RESUMO

The Lesser Xing'an-Zhangguangcai Range of northeast China is located in the eastern segment of the Central Asian Orogenic Belt (CAOB), which records intense magmatism during the Mesozoic. The petrogenesis and geodynamic setting of the Early Jurassic intrusive rocks in this region are unclear. In this paper, we present new zircon U-Pb age and whole-rock geochemical data for these intrusive rocks to investigate their origins and tectonic setting. Zircon U-Pb dating suggests these intrusive rocks were emplaced during the Early Jurassic (197-187 Ma). The granites are enriched in silica and alkali, and depleted in MgO and CaO. They are metaluminous to weakly peraluminous, and have high A/CNK values and low zircon saturation temperatures (TZr ~ 779°C), suggesting they are highly fractionated I-type granites derived by partial melting of lower crustal materials. The granites exhibit negative Nb, Ta, P, Eu, and Ti anomalies due to fractional crystallization. The diorites and gabbros have low SiO2 contents and high Mg# values, and are enriched in light rare earth and large-ion lithophile (Ba, K, and Sr) elements, and depleted in heavy rare earth and high field strength (Nb, Ta, and Ti) elements. The geochemical characteristics show that the mafic magmas were derived by partial melting of mantle that had been metasomatized by subduction-related fluids. Based on the geochemical characteristics of coeval intrusive rocks and the regional geological setting, we suggest the Early Jurassic intrusive rocks in the Lesser Xing'an-Zhangguangcai Range were formed along an active continental margin, possibly as a result of bidirectional subduction of the Mudanjiang Oceanic plate between the Jiamusi and Songnen-Zhangguangcai Range massifs.


Assuntos
Sedimentos Geológicos , China , Sedimentos Geológicos/análise , Sedimentos Geológicos/química , Geologia , Fenômenos Geológicos , Zircônio/química , Dióxido de Silício/química , Dióxido de Silício/análise , Silicatos
3.
J Occup Environ Hyg ; 21(8): 602-622, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39042882

RESUMO

Airborne respirable crystalline silica (RCS) has been a widely recognized hazard in the United States for nearly 100 years, yet it continues to pose a risk to construction tradespersons, among others. RCS exposures vary widely depending on site conditions and tools and materials used. The proper use of engineering, administrative, and personal protective equipment (PPE) controls can effectively reduce exposure to RCS. Historically, others have reviewed available RCS exposure data among construction trades and reported that there were considerable data gaps and variability that needed to be addressed. This current assessment aimed to synthesize available peer-reviewed exposure studies to determine potential RCS exposures during the use of common construction materials and evaluate to what extent data gaps and variability persist. Twenty-eight studies were identified that reported RCS exposure during construction tasks. After conversion to the unit of µg/m3, reported measurements from samples collected for varying durations ranged from 6.0 to 75,500 µg/m3 for work with concrete, 80 to 4,240 µg/m3 for work with brick, <59 to 10,900 µg/m3 for work with mortar, 90 to 44,370 µg/m3 for work with engineered stone, and 70 to 380 µg/m3 for work with roof tile. To better facilitate pooling data across studies, future researchers should report their sample duration, clarify how time-weighted average (TWA) exposure data are calculated, report the silica content of the material being manipulated, and specify whether samples were collected while the task was performed in isolation or on a worksite where other silica-containing materials were also actively handled. When reporting results as respirable quartz, it is important to note whether any other polymorphic forms of silica were detected. It is ultimately the employer's responsibility to train employees and monitor and control RCS exposures on construction worksites. To do this effectively, it is important to have a clear understanding of the tasks, materials, and site conditions where intervention is most urgently needed.


Assuntos
Poluentes Ocupacionais do Ar , Indústria da Construção , Materiais de Construção , Exposição por Inalação , Exposição Ocupacional , Dióxido de Silício , Dióxido de Silício/análise , Exposição Ocupacional/análise , Exposição por Inalação/análise , Exposição por Inalação/prevenção & controle , Poluentes Ocupacionais do Ar/análise , Humanos , Estados Unidos , Equipamento de Proteção Individual , Monitoramento Ambiental/métodos
4.
J Occup Environ Hyg ; 21(8): 539-550, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38958555

RESUMO

Direct-on-Filter (DoF) analysis of respirable crystalline silica (RCS) by Fourier Transform Infrared (FTIR) spectroscopy is a useful tool for assessing exposure risks. With the RCS exposure limits becoming lower, it is important to characterize and reduce measurement uncertainties. This study systematically evaluated two filter types (i.e., polyvinyl chloride [PVC] and polytetrafluoroethylene [PTFE]) for RCS measurements by DoF FTIR spectroscopy, including the filter-to-filter and day-to-day variability of blank filter FTIR reference spectra, particle deposition patterns, filtration efficiencies, and pressure drops. For PVC filters sampled at a flow rate of 2.5 L/min for 8 h, the RCS limit of detection (LOD) was 7.4 µg/m3 when a designated laboratory reference filter was used to correct the absorption by the filter media. When the spectrum of the pre-sample filter (blank filter before dust sampling) was used for correction, the LOD could be up to 5.9 µg/m3. The PVC absorption increased linearly with reference filter mass, providing a means to correct the absorption differences between the pre-sample and reference filters. For PTFE, the LODs were 12 and 1.2 µg/m3 when a designated laboratory blank or the pre-sample filter spectrum was used for blank correction, respectively, indicating that using the pre-sample blank spectrum will reduce RCS quantification uncertainty. Both filter types exhibited a consistent radially symmetric deposition pattern when particles were collected using 3-piece cassettes, indicating that RCS can be quantified from a single measurement at the filter center. The most penetrating aerodynamic diameters were around 0.1 µm with filtration efficiencies ≥ 98.8% across the measured particle size range with low-pressure drops (0.2-0.3 kPa) at a flow rate of 2.5 L/min. This study concludes that either the PVC or the PTFE filters are suitable for RCS analysis by DoF FTIR, but proper methods are needed to account for the variability of blank absorption among different filters.


Assuntos
Politetrafluoretileno , Cloreto de Polivinila , Dióxido de Silício , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Cloreto de Polivinila/química , Dióxido de Silício/análise , Dióxido de Silício/química , Politetrafluoretileno/química , Filtração/instrumentação , Filtros de Ar , Poeira/análise , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise , Monitoramento Ambiental/métodos , Monitoramento Ambiental/instrumentação , Limite de Detecção , Tamanho da Partícula , Exposição por Inalação/análise
5.
Occup Environ Med ; 81(6): 308-312, 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38937079

RESUMO

OBJECTIVES: Previous radiologic and histopathologic studies suggest respirable crystalline silica (RCS) overexposure has been driving the resurgence of pneumoconiosis among contemporary US coal miners, with a higher prevalence of severe disease in Central Appalachia. We sought to better understand RCS exposure among US underground coal miners. METHODS: We analysed RCS levels, as measured by respirable quartz, from coal mine dust compliance data from 1982 to 2021. RESULTS: We analysed 322 919 respirable quartz samples from 5064 US underground coal mines. Mean mine-level respirable quartz percentage and mass concentrations were consistently higher for Central Appalachian mines than the rest of the USA. Mean mine-level respirable quartz mass concentrations decreased significantly over time, from 0.116 mg/m3 in 1982 to as low as 0.017 mg/m3 for Central Appalachian mines, and from 0.089 mg/m3 in 1983 to 0.015 mg/m3 in 2020 for the rest of the USA. Smaller mine size, location in Central Appalachia, lack of mine safety committee and thinner coal seams were predictive of higher respirable quartz mass concentrations. CONCLUSIONS: These data substantially support the association between RCS overexposure and the resurgence of coal workers' pneumoconiosis in the USA, particularly in smaller mines in Central Appalachia.


Assuntos
Minas de Carvão , Poeira , Exposição Ocupacional , Quartzo , Dióxido de Silício , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/efeitos adversos , Dióxido de Silício/análise , Dióxido de Silício/efeitos adversos , Estados Unidos , Poeira/análise , Quartzo/análise , Região dos Apalaches/epidemiologia , Exposição por Inalação/análise , Exposição por Inalação/efeitos adversos , Poluentes Ocupacionais do Ar/análise
6.
Artigo em Chinês | MEDLINE | ID: mdl-38538236

RESUMO

Objective: To investigate the differences and applicability of free silica detection methods of different crystal forms in dust, and to provide a basis for the selection of various methods. Methods: From December 2021 to June 2022, dust samples from 20 enterprises in different industries in 18 cities in Henan Province were randomly selected as the investigation objects. X-ray diffraction (XRD) method was used to analyze the samples and classify the samples. Based on GBZ/T 192.4-2007 "Determination of Dust in the Air of Workplace-Part 4: Content of Free Silica in Dust", pyrophosphate method and infrared spectrophotometry were used for quantitative determination. The measured results were analyzed by paired sample t test to evaluate the advantages and disadvantages of the two methods and their applicable scope. Results: The XRD results of 20 dust samples could be divided into α, ß, γ crystal types and the mixed type of α and γ. There was no significant difference between pyrophosphate method and infrared spectrophotometry (P=0.180). The pyrophosphate method results of ß, γ and α, γ mixed crystalline free silica were significantly higher than those of infrared spectrophotometry, and the difference was statistically significant (P<0.001) . Conclusion: Pyrophosphate method and infrared spectrophotometry are suitable for α-type free silica, while pyrophosphate method is suitable for ß, γ and α, γ mixed crystalline free silica.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Dióxido de Silício/análise , Difosfatos , Poeira/análise , Espectrofotometria Infravermelho , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise
7.
Artigo em Inglês | MEDLINE | ID: mdl-38541362

RESUMO

The prevalence of dementia increases with nearly 10 million new cases each year, with Alzheimer's disease contributing to 60-70% of cases. Environmental factors such as drinking water have been evaluated to determine if a relationship exists between trace elements in drinking water and the risk of developing cognitive disorders in the elderly. The purpose of the current systematic review was to evaluate an association between the composition of drinking water and cognitive function in the elderly. In accordance with the Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines, a literature search was conducted using PubMed and CINAHL databases. A total of 10 studies were included in the current systematic review. Aluminum is the most commonly evaluated trace element in studies (n = 8), followed by silica (n = 5), calcium (n = 4), and fluoride (n = 4). Aluminum exposure showed an increased risk of cognitive decline in four studies, with no association reported in the other studies. Higher silica and pH levels were shown to be protective against a decline in cognitive function. A similar protective effect of calcium was found in two studies. Future research should measure multiple trace mineral levels in all water sources to evaluate the impact on cognitive function.


Assuntos
Disfunção Cognitiva , Água Potável , Oligoelementos , Idoso , Humanos , Alumínio/análise , Cálcio/análise , Cognição , Disfunção Cognitiva/induzido quimicamente , Disfunção Cognitiva/epidemiologia , Água Potável/análise , Dióxido de Silício/análise , Oligoelementos/análise
8.
Anal Chem ; 96(12): 4942-4951, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38478960

RESUMO

Bromochloro alkanes (BCAs) have been manufactured for use as flame retardants for decades, and preliminary environmental risk screening suggests they are likely to behave similarly to polychlorinated alkanes (PCAs), subclasses of which are restricted as Stockholm Convention Persistent Organic Pollutants (POPs). BCAs have rarely been studied in the environment, although some evidence suggests they may migrate from treated-consumer materials into indoor dust, resulting in human exposure via inadvertent ingestion. In this study, BCA-C14 mixture standards were synthesized and used to validate an analytical method. This method relies on chloride-enhanced liquid chromatography-electrospray ionization-Orbitrap-high resolution mass spectrometry (LC-ESI-Orbitrap-HRMS) and a novel CP-Seeker integration software package for homologue detection and integration. Dust sample preparation via ultrasonic extraction, acidified silica cleanup, and fractionation on neutral silica cartridges was found to be suitable for BCAs, with absolute recovery of individual homologues averaging 66 to 78% and coefficients of variation ≤10% in replicated spiking experiments (n = 3). In addition, a total of 59 indoor dust samples from six countries, including Australia (n = 10), Belgium (n = 10), Colombia (n = 10), Japan (n = 10), Thailand (n = 10), and the United States of America (n = 9), were analyzed for BCAs. BCAs were detected in seven samples from the U.S.A., with carbon chain lengths of C8, C10, C12, C14, C16, C18, C24 to C28, C30 and C31 observed overall, though not detected in samples from any other countries. Bromine numbers of detected homologues in the indoor dust samples ranged Br1-4 as well as Br7, while chlorine numbers ranged Cl2-11. BCA-C18 was the most frequently detected, observed in each of the U.S.A. samples, while the most prevalent degrees of halogenation were homologues of Br2 and Cl4-5. Broad estimations of BCA concentrations in the dust samples indicated that levels may approach those of other flame retardants in at least some instances. These findings suggest that development of quantification strategies and further investigation of environmental occurrence and health implications are needed.


Assuntos
Poluição do Ar em Ambientes Fechados , Retardadores de Chama , Humanos , Monitoramento Ambiental , Organofosfatos/análise , Poeira/análise , Retardadores de Chama/análise , Poluição do Ar em Ambientes Fechados/análise , Halogênios , Dióxido de Silício/análise
9.
J Occup Environ Hyg ; 21(4): 247-258, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38451548

RESUMO

Exposure to respirable dust and crystalline silica (SiO2) has been linked to chronic obstructive pulmonary disease, silicosis, cancer, heart disease, and other respiratory diseases. Relatively few studies have measured respirable dust and SiO2 concentrations among workers at brick kilns in low- and middle-income countries. The purpose of this study was to measure personal breathing zone (PBZ) respirable dust and SiO2 concentrations among workers at one brick kiln in Bhaktapur, Nepal. A cross-sectional study was conducted among 49 workers in five job categories: administration, fire master, green (unfired) brick hand molder, green brick machine molder, and top loader. PBZ air samples were collected from each worker following Methods 0600 (respirable dust) and 7500 (respirable crystalline SiO2: cristobalite, quartz, tridymite) of the U.S. National Institute for Occupational Safety and Health. Eight-hour time-weighted average (TWA) respirable dust and quartz concentrations were also calculated. SiO2 percentage was measured in one bulk sample each of wet clay, the release agent used by green brick hand molders, and top coat soil at the brick kiln. The geometric mean (GM) sample and TWA respirable dust concentrations were 0.20 (95% confidence interval [CI]: 0.16, 0.27) and 0.12 (95% CI: 0.09, 0.16) mg/m3, respectively. GM sample and TWA quartz concentrations were 15.28 (95% CI: 11.11, 21.02) and 8.60 (95% CI: 5.99, 12.34) µg/m3, respectively. Job category was significantly associated with GM sample and TWA respirable dust and quartz concentrations (all p < 0.0001). Top loaders had the highest GM sample and TWA respirable dust concentrations of 1.49 and 0.99 mg/m3, respectively. Top loaders also had the highest GM sample and TWA quartz concentrations of 173.08 and 114.39 µg/m3, respectively. Quartz percentages in bulk samples were 16%-27%. Interventions including using wet methods to reduce dust generation, administrative controls, personal protective equipment, and education and training should be implemented to reduce brick kiln worker exposures to respirable dust and SiO2.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Dióxido de Silício/análise , Exposição Ocupacional/análise , Quartzo/análise , Poeira/análise , Poluentes Ocupacionais do Ar/análise , Nepal , Estudos Transversais , Exposição por Inalação/análise
10.
Environ Res ; 251(Pt 2): 118773, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38522742

RESUMO

An increasing number of silicosis cases have been reported related to the use of silica agglomerates. Many studies agree on the severity of this disease, which often presents with severe clinical forms in young workers and after a short latency period. Are there differences in the composition of dust generated by cutting and polishing with silica agglomerates versus granite and marble? Does the use of water injection reduce the risk associated with the use of these materials? We carried out a comparative observational-analytical study, measuring the concentration of dust generated during different machining operations on three different materials: granite, marble, and silica agglomerates. The effect of water injection on dust generation was evaluated. Personal sampling pumps were used, connected to a cyclone with polyvinyl chloride filters. The flow rate of the pumps was adjusted using a piston flowmeter. Measurements with a cascade impactor were made to assess the size distribution of respirable crystalline silica particles within the respirable fraction. In addition, environmental measurements with a spectrometer were made. 10 tests were carried out on granite and silica agglomerates for each procedure. In the case of marble, with very low silica content, only 2 tests of each type were carried out. Duration of each measurement was between 6 and 25 min. Cleaning times were set for each of the operations. The amount of dust collected in the respirable fraction was 70.85, 32.50 and 35.78 mg/m3 for dry cutting; 6.50, 3.75 and 3.95 mg/m3 for wet cutting; and 21.35, 13.68 and 17.50 mg/m3 for dry polishing, for granite, marble, and silica agglomerates respectively. Dry procedures in marble, silica agglomerates and granite showed higher dust concentration of particles smaller than 0.5 µm. Silica agglomerates showed higher concentrations of respirable crystalline silica particles than granite and marble, mainly with dry procedures. The greater production of small particles in dry and wet procedures with silica agglomerates shows that water injection is an insufficient preventive measure.


Assuntos
Poeira , Exposição Ocupacional , Dióxido de Silício , Silicose , Dióxido de Silício/análise , Dióxido de Silício/química , Poeira/análise , Silicose/prevenção & controle , Silicose/etiologia , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Água/química , Medição de Risco , Tamanho da Partícula , Prevenção Primária/métodos , Exposição por Inalação/análise , Exposição por Inalação/prevenção & controle , Poluentes Ocupacionais do Ar/análise
11.
Environ Monit Assess ; 196(4): 398, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38530475

RESUMO

The current study was conducted within the context of the Holocene era in Sebkha El-Guettiate, located in southeastern Tunisia. The aim was to determine the factors influencing the geochemical and mineralogical composition of sediments and to elucidate the sedimentary characteristics of the Holocene within the Sebkha core. We examined a sediment core extending 100 cm from this Sebkha, subjecting it to comprehensive analysis to uncover its sedimentological, mineralogical, and geochemical properties. Several techniques were employed to strengthen and validate the connections between geochemical and mineralogical analyses, including X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopy (SEM), and infrared (IR) spectroscopy, among others. Furthermore, statistical analyses utilizing principal component analysis (PCA) were applied to the results of the geochemical and mineralogical studies, aiding in the identification of patterns and relationships. A comprehensive mineralogical assessment of the core's sediments revealed the presence and interpretation of carbonate minerals, evaporite minerals, and detrital minerals. Through the application of infrared (IR) spectrometer techniques to all sediment samples, we gained insight into the mineralogical components and the distribution of key elements such as quartz, kaolinite, calcite, feldspar, and organic carbon. The geochemical composition demonstrated a clear dominance of silica (SiO2), accompanied by fluctuations in carbonate percentages (CaCO3). The prominent major elements, primarily magnesium (Mg) and calcium (Ca) originating from dolomitization, sodium (Na) and chlorine (Cl) from halite, and calcium (Ca) from gypsum, exhibited varying levels. Results from Rock-Eval 6 pyrolysis indicated that the organic matter within the sediments is generally a mixture of terrestrial and aquatic origins. This study provides practical information that underscores the diverse origins contributing to Sebkha sediment formation, often influenced by saline systems.


Assuntos
Cálcio , Dióxido de Silício , Cálcio/análise , Dióxido de Silício/análise , Tunísia , Monitoramento Ambiental , Minerais/análise , Carbonato de Cálcio/análise , Carbonatos/análise
12.
Ann Work Expo Health ; 68(4): 437-441, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38412287

RESUMO

Personal air monitoring using a TSI SidePak AM520 personal aerosol monitor was performed on a northern Colorado construction site during five tasks from the OSHA Table 1: Specified Exposure Control Methods When Working With Materials Containing Crystalline Silica to estimate silica dust concentrations in real time. Photometric measurements were modified using a gravimetric correction factor and a % respirable crystalline silica adjustment. Each task was sampled once; sample time ranged from 14 min to 40 min, with a mean sample time of 27 min. The mean silica dust concentration estimates (µg/m3) (standard deviation [SD]) for the five tasks computed from the TSI SidePak AM520 respirable dust measurements were core drilling 12 µg/m3 [2.46], grinding 918 µg/m3 [1134.08], cutting with a walk-behind saw 36 µg/m3 [79.67], jackhammering 27 µg/m3 [23.24], and dowel drilling 66 µg/m3 [77.65]. Silica exposure estimates from real-time monitoring can be used to identify exposures that may be related to inadequate controls or worker behaviors that contribute to peak exposures. Respirable crystalline silica exposure estimates presented here are likely not generalizable to other construction sites or tasks.


Assuntos
Poluentes Ocupacionais do Ar , Poeira , Monitoramento Ambiental , Exposição por Inalação , Exposição Ocupacional , Dióxido de Silício , Exposição Ocupacional/análise , Dióxido de Silício/análise , Poluentes Ocupacionais do Ar/análise , Exposição por Inalação/análise , Humanos , Poeira/análise , Monitoramento Ambiental/métodos , Indústria da Construção , Colorado , Materiais de Construção/análise , Aerossóis/análise , Fatores de Tempo
13.
Artigo em Chinês | MEDLINE | ID: mdl-38403418

RESUMO

Objective: To study and compare the occupational exposure limits (OELs) of coal dust between China and foreign countries, understand the OEL of coal dust in China, and provide data and basis for revising the OEL of coal dust in China. Methods: In August 2023, by searching the official websites of limits setting institutions in relevant countries and regions at home and abroad, collecting and sorting out the OELs of coal dust issued by 10 limit setting institutions in 6 countries and the background information of the formulation, and conducting specific analysis on the classification, limit level and formulation principles of coal dust OEL in each country/institution. Results: In China and Japan, the total dust and respirable dust of coal dust OEL were established respectively, while in other countries, only the time-weighted average concentration (TWA) of respirable coal dust exposure was established. The TWA prescribed by China's Notional Health Commission, the United States Occupational Safety and Health Administration (OSHA) , the United States Mining Safety and Health Administration (MSHA) and the Australian Safety Work Bureau when the SiO(2) content was less than 5% were 5, 2.4, 2 and 3 mg/m(3) respectively. China GBZ 2.1-2019 sets the limit of 2.5 mg/m(3) for respirable coal dust with SiO(2) content less than 10%. The TWA set by the American Conference of Government Industrial Hygienists (ACGIH) and the South African Department of Mines and Energy (DME) for anthracite coal were 0.4 and 0.8 mg/m(3), respectively, and bituminous coal or lignite were 0.9 and 1.8 mg/m(3), respectively. The respirable coal dust TWA set by the National Institute for Occupational Safety and Health (NIOSH) in the United States was 1 mg/m(3), and the TWA set by the New Zealand Work Safety Authority was 3 mg/m(3). Conclusion: At present, the OEL of coal dust in China is at a relatively loose level, and it is suggested to further explore the possibility of revising coal dust OEL.


Assuntos
Poluentes Ocupacionais do Ar , Minas de Carvão , Exposição Ocupacional , Estados Unidos , Dióxido de Silício/análise , Carvão Mineral , Austrália , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Poeira/análise , China , Poluentes Ocupacionais do Ar/análise
14.
Ann Work Expo Health ; 68(3): 269-279, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38206108

RESUMO

OBJECTIVES: Since the 1920s, Zambia's mining sector has experienced growth, which has increased the number of mine workers employed in the industry. Consequently, the potential for occupational exposure and prevalence of occupational diseases have also increased. Unfortunately, Zambia does not currently have legislative guidelines for workplace air monitoring and compliance. This study's objectives were to evaluate copper miners' personal exposure to respirable dust and respirable crystalline silica (RCS) and to assess workplace compliance using the European Standard for workplace air monitoring and measurement (EN689:2018). METHODS: This cross-sectional study collected 100 personal respirable dust exposure samples at a Zambian copper mine in 2023. These samples were weighed using NIOSH method 0600 and analyzed for crystalline silica using Fourier transform infrared spectroscopy (KBr pellet) (NIOSH method 7602). Additionally, 253 respirable dust exposure measurements collected at the mine between 2017 and 2022 were included for comparison. RESULTS: The median respirable dust exposure for the 2023 exposure measurements was 0.200 mg/m3 (95th percentile 2.871 mg/m3) compared to 0.400 mg/m3 (95th percentile 3.050 mg/m3) for the historic data. The median RCS exposure was 0.012 mg/m3 (95th percentile 0.163 mg/m3). Using EN689:2018, it was found that from 15 work areas, only six work areas complied with the standard for respirable dust exposure and only seven work areas complied with the standard for RCS exposure. CONCLUSIONS: At the mining site, several work areas had substantial exposure to respirable dust and RCS. Therefore, management needs to prioritize these areas when implementing control measures to reduce dust exposure. For the Zambia mining industry to manage exposure to respirable dust and RCS, it is necessary to implement standardized monitoring strategies. This study has demonstrated that EN689:2018 can be used successfully to determine compliance among Zambian mining work areas.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Cobre , Zâmbia , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Estudos Transversais , Dióxido de Silício/análise , Exposição por Inalação/análise , Monitoramento Ambiental/métodos
15.
Medicine (Baltimore) ; 103(2): e36969, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38215125

RESUMO

Stone quarry activities in Nigeria are mostly unregulated such that the workers in these quarries are continuously exposed to the inhalation of silica dust. It has been observed that silica dust particles negatively impact the health of stone quarry workers which usually manifest as respiratory difficulties, asthma-like illnesses and other adventitious events of the lungs. The study was designed to evaluate the probable immunological impact of silica dust inhalation from stone crushing by workers. Blood samples were collected from consenting workers and analyzed for total white blood cells and their subsets. Absolute CD4 cells numbers were also determined. The results indicated that neutrophils and eosinophils numbers increased significantly (P < .05) and CD4 counts declined significantly (P < .001). Alteration in these proportions is a pointer to the injurious impact of silica dust on the immune system of these workers. The findings in this study should spur actions in the education of these workers on the need for the use of proper personal protection equipment and the establishment of a scheme to periodically carry out a health assessment check to identity those at most risk of developing chronic illnesses.


Assuntos
Exposição Ocupacional , Humanos , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Nigéria/epidemiologia , Poeira/análise , Dispneia , Dióxido de Silício/análise
16.
Cell ; 187(3): 782-796.e23, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38244547

RESUMO

The rapid kinetics of biological processes and associated short-lived conformational changes pose a significant challenge in attempts to structurally visualize biomolecules during a reaction in real time. Conventionally, on-pathway intermediates have been trapped using chemical modifications or reduced temperature, giving limited insights. Here, we introduce a time-resolved cryo-EM method using a reusable PDMS-based microfluidic chip assembly with high reactant mixing efficiency. Coating of PDMS walls with SiO2 virtually eliminates non-specific sample adsorption and ensures maintenance of the stoichiometry of the reaction, rendering it highly reproducible. In an operating range from 10 to 1,000 ms, the device allows us to follow in vitro reactions of biological molecules at resolution levels in the range of 3 Å. By employing this method, we show the mechanism of progressive HflX-mediated splitting of the 70S E. coli ribosome in the presence of the GTP via capture of three high-resolution reaction intermediates within 140 ms.


Assuntos
Proteínas de Escherichia coli , Escherichia coli , Ribossomos , Microscopia Crioeletrônica/métodos , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Proteínas de Ligação ao GTP/metabolismo , Microfluídica/métodos , Ribossomos/metabolismo , Dióxido de Silício/análise
17.
Scand J Work Environ Health ; 50(3): 178-186, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38264956

RESUMO

OBJECTIVES: The quantitative job-exposure matrix SYN-JEM consists of various dimensions: job-specific estimates, region-specific estimates, and prior expert ratings of jobs by the semi-quantitative DOM-JEM. We analyzed the effect of different JEM dimensions on the exposure-response relationships between occupational silica exposure and lung cancer risk to investigate how these variations influence estimates of exposure by a quantitative JEM and associated health endpoints. METHODS: Using SYN-JEM, and alternative SYN-JEM specifications with varying dimensions included, cumulative silica exposure estimates were assigned to 16 901 lung cancer cases and 20 965 controls pooled from 14 international community-based case-control studies. Exposure-response relationships based on SYN-JEM and alternative SYN-JEM specifications were analyzed using regression analyses (by quartiles and log-transformed continuous silica exposure) and generalized additive models (GAM), adjusted for age, sex, study, cigarette pack-years, time since quitting smoking, and ever employment in occupations with established lung cancer risk. RESULTS: SYN-JEM and alternative specifications generated overall elevated and similar lung cancer odds ratios ranging from 1.13 (1st quartile) to 1.50 (4th quartile). In the categorical and log-linear analyses SYN-JEM with all dimensions included yielded the best model fit, and exclusion of job-specific estimates from SYN-JEM yielded the poorest model fit. Additionally, GAM showed the poorest model fit when excluding job-specific estimates. CONCLUSION: The established exposure-response relationship between occupational silica exposure and lung cancer was marginally influenced by varying the dimensions of SYN-JEM. Optimized modelling of exposure-response relationships will be obtained when incorporating all relevant dimensions, namely prior rating, job, time, and region. Quantitative job-specific estimates appeared to be the most prominent dimension for this general population JEM.


Assuntos
Neoplasias Pulmonares , Exposição Ocupacional , Humanos , Exposição Ocupacional/análise , Ocupações , Estudos de Casos e Controles , Dióxido de Silício/análise
18.
Ann Work Expo Health ; 68(1): 48-57, 2024 01 08.
Artigo em Inglês | MEDLINE | ID: mdl-37824745

RESUMO

BACKGROUND: Globally, the number of small-scale miners (SSM) is estimated to be more than 25 million, but it supports the livelihoods of around 100 million individuals. In Tanzania, the number of SSM has increased from an estimated 150,000 in 1987 to ~1.5 million in 2017. The miners are at a high risk of occupational-related health challenges. The study aimed to assess the concentrations of respirable crystalline silica (RCS) and radon among the tanzanite mining communities in Simanjiro District, Tanzania. METHODS: We carried out a cross-sectional study involving the Mererani mines in Tanzania. These are underground mines comprised of informally employed miners, i.e. SSM. Concentrations of RCS and radon gas were measured in 44 study units, i.e. 22 mining pits and within 22 houses in the general community, e.g. shops in the peri-mining community. A total of 132 respirable personal dust exposure samples (PDS), 3 from each of the study units were taken, but only 66 PDS from the mining pits were analysed, as this was the main interest of this study. Radon concentration was measured by continuous monitoring throughout the working shift (and overnight for residences) using AlphaGuard monitor. The medians and comparison to the reference values, OSHA USA PEL and WHO/IARC references, were done for RCS and radon, respectively, using SPSS Ver. 27.0.0). RESULTS: The median time-weighted average (TWA) concentration of the RCS in the mining pits was 1.23 mg/m3. Of all 66 personal dust samples from the mining pits, 65 (98.5%) had concentrations of RCS above the Occupational Safety and Health Administration (OSHA) permissible exposure limit (PEL) of 0.05 mg/m3. Mining pits had a median radon concentration of 169.50 bq/m3, which is above the World Health Organization (WHO)/International Commission on Radiation Protection (ICRP) recommended reference of 100.00 bq/m3 but not above the upper reference of 300.00 bq/m3, while the community buildings had a median radon concentration of 88.00 bq/m3. Overall, 9 (20.5%) and 17 (38.6%) radon measurements were above 300.00 bq/m3 and between 100.00 and 300.00 bq/m3 references, respectively. Specifically, in the mining pits, 9 (40.9%) test results were above 300.00 bq/m3, while none of the test results in the community was above 300.00 bq/m3. CONCLUSION: The tanzanite SSM in Mererani we highly exposed to RCS, which increases the risk of pulmonary diseases, including silicosis, tuberculosis, and pulmonary malignancies. Immediate action by OSHA Tanzania should be enforcement of wearing respirators by all miners throughout the working hours. Health education programmes to the SSM must be strengthened and OSHA Tanzania should adopt the 0.05 mg/m3 PEL, and enforce other occupational health and safety measures, including regular use of dust suppression mechanisms (water spray and wet drilling) and monitoring of RCS exposures among SSM. Monitoring of radon exposure both in the mining pits and community buildings should be conducted, and mitigation measures should be implemented in areas that exceed the reference level of 100.00 bq/m3.


Assuntos
Exposição Ocupacional , Radônio , Humanos , Exposição Ocupacional/análise , Radônio/análise , Tanzânia , Estudos Transversais , Dióxido de Silício/análise , Poeira/análise
19.
Ann Work Expo Health ; 68(2): 170-179, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38096573

RESUMO

There is a significant silicosis risk for workers fabricating engineered stone (ES) products containing crystalline silica. The aims of this study by SafeWork NSW were to: (i) assess current worker exposure to respirable dust (RD) and respirable crystalline silica (RCS) following a 5-y awareness and compliance program of inspections in ES workshops and (ii) to identify improvements in work practices from the available evidence base to further reduce exposures. One hundred and twenty-three personal full shift samples taken on as many workers and 34 static samples across 27 workshops fabricating ES were included in the final assessment. The exposure assessment was conducted using Casella Higgins-Dewell cyclones (Casella TSI) placed in the breathing zone of workers attached to SKC Air Check XR 5000 or SKC Chek TOUCH sampling pumps. Sample filters were sent to an ISO (2017) 17025:2017 accredited laboratory for gravimetric analysis for RD and X-Ray Diffraction (XRD) analysis to determine the amount of deposited RCS i.e. alpha-quartz and cristobalite. All workshops used wet methods of fabrication. The geometric mean (GM) of the pooled result for respirable dust (RD) was 0.09 mg/m3 TWA-8 h and 0.034 mg/m3 TWA-8 h for RCS. The highest exposed workers with a GM RCS of 0.062 mg/m3 TWA-8 h were those using pneumatic hand tools for cutting or grinding combined with polishing tasks. Workers operating semiautomated routers and edge polishers had the lowest GM RCS exposures of 0.022 mg/m3 TWA-8 h and 0.018 mg/m3 TWA-8 h respectively. Although ES workers remain exposed to RCS above the workplace exposure limit (WEL) of 0.05 mg/m 3 TWA-8 h, these results point to a very substantial reduction in exposures compared to poorly controlled dry methods of fabrication. Therefore, the wearing of respiratory protection by workers remains necessary until further control measures are more widely adopted across the entire industry e.g. reduction in the crystalline silica content of ES.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Humanos , Dióxido de Silício/análise , Exposição Ocupacional/análise , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Exposição por Inalação/análise
20.
Arch Environ Occup Health ; 78(9-10): 501-506, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38095547

RESUMO

Long term exposure to silica at worksites can cause silicosis. This typically has two radiographic forms, simple silicosis and complicated or conglomerate silicosis. Patients with acute silicosis have rapid progression of disease with fulminant respiratory failure over months rather than years. The patient described in this case report had a one-time 4 to 5-h exposure to silica and sand dust at work when his mask malfunctioned. He developed cough and shortness of breath. During his initial clinic visit he had significant cough. His chest examination was clear without crackles or wheezes. His pulmonary function tests were within normal limits. His chest x-ray was clear. Both symptoms, especially the cough, persisted over the next 6+ months even after treatment with oral corticosteroids and inhaled corticosteroids and long-acting beta agonists. Consequently, this patient developed severe cough following a one-time exposure to silica particulates. Laboratory studies have demonstrated that silica exposure can cause reactive oxygen species which potentially could have activated transient receptor potential vanilloid 1 channels in the afferent sensory nerves in his bronchial epithelium. This could cause sustained cough for more than 6 months. His symptoms improved but did not resolve with corticosteroid treatment. Therefore, this case demonstrates that acute silica exposure can cause sustained airway symptoms in healthy workers.


Assuntos
Exposição Ocupacional , Silicose , Masculino , Humanos , Dispneia/complicações , Silicose/etiologia , Dióxido de Silício/análise , Tosse/complicações , Poeira , Corticosteroides
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA