Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.616
Filtrar
1.
Transl Vis Sci Technol ; 13(5): 8, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38739084

RESUMO

Purpose: This study aimed to evaluate the ocular characteristics associated with spontaneously high myopia in adult nonhuman primates (NHPs). Methods: A total of 537 eyes of 277 macaques with an average age of 18.53 ± 3.01 years (range = 5-26 years), raised in a controlled environment, were included. We measured ocular parameters, including spherical equivalent (SE), axial length (AXL), and intraocular pressure. The 45-degree fundus images centered on the macula and the disc assessed the fundus tessellation and parapapillary atrophy (PPA). Additionally, optical coherence tomography (OCT) was used to measure the thickness of the retinal nerve fiber layer (RNFL). Results: The mean SE was -1.58 ± 3.71 diopters (D). The mean AXL was 18.76 ± 0.86 mm. The prevalence rate of high myopia was 17.7%. As myopia aggravated, the AXL increased (r = -0.498, P < 0.001). Compared with non-high myopia, highly myopic eyes had a greater AXL (P < 0.001), less RNFL thickness (P = 0.004), a higher incidence of PPA (P < 0.001), and elevated grades of fundus tessellation (P < 0.001). The binary logistic regression was performed, which showed PPA (odds ratio [OR] = 4.924, 95% confidence interval [CI] = 2.375-10.207, P < 0.001) and higher grades of fundus tessellation (OR = 1.865, 95% CI = 1.474-2.361, P < 0.001) were independent risk characteristics for high myopia. Conclusions: In NHPs, a higher grade of fundus tessellation and PPA were significant biomarkers of high myopia. Translational Relevance: The study demonstrates adult NHPs raised in conditioned rooms have a similar prevalence and highly consistent fundus changes with human beings, which strengthens the foundation for utilizing macaques as an animal model in high myopic studies.


Assuntos
Fundo de Olho , Tomografia de Coerência Óptica , Animais , Masculino , Feminino , Modelos Animais de Doenças , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Atrofia Óptica/patologia , Atrofia Óptica/epidemiologia , Pressão Intraocular/fisiologia , Miopia Degenerativa/patologia , Miopia Degenerativa/epidemiologia , Fibras Nervosas/patologia , Comprimento Axial do Olho/patologia , Células Ganglionares da Retina/patologia , Miopia/patologia , Miopia/epidemiologia , Miopia/veterinária
2.
Int Ophthalmol ; 44(1): 226, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38758396

RESUMO

PURPOSE: Glaucoma and multiple sclerosis (MS) can cause optic disc pathology and, in this way, affect optical coherence tomography (OCT) data. In this context, the objective of this study is to investigate the changes in the mean, quadrant, and sector data measured by OCT in glaucoma and MS patients. METHODS: The sample of this prospective cohort study consisted of 42 MS patients (84 eyes), 34 Primary open-angle glaucomas patients (67 eyes), and 24 healthy control subjects (48 eyes). The MS group was divided into two groups according to the presence of a history of optic neuritis. Accordingly, those with a history of optic neuritis were included in the MS ON group, and those without a history of optic neuritis were included in the MS NON group. The differences between these groups in the mean, quadrant, and sector data related to the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) were evaluated. RESULTS: Superior nasal (SN), superior temporal (ST), inferior nasal (IN), and superior quadrant (SUP) values were significantly lower in the glaucoma group than in the MS group (p < 0.05). The mean superior GCC (GCC SUP) value was significantly lower in the MS ON group than in the glaucoma group (p < 0.05). On the other hand, SN, ST, inferior temporal (IT), IN, average RNFL (AVE RNFL), semi-average superior RNFL (SUP AVE RNFL), semi-average inferior RNFL (INF AVE RNFL), SUP, and inferior quadrant RNFL (INF) values were significantly lower in the glaucoma group than in the MS NON group (p < 0.05). CONCLUSION: RNFL and GCC parameters get thinner in MS and glaucoma patients. While the inferior and superior RNFL quadrants are more frequently affected in glaucoma patients, the affected quadrants vary according to the presence of a history of optic neuritis in MS patients. It is noteworthy that the GCC superior quadrant was thin in MS ON patients. The findings of this study indicate that OCT data may be valuable in the differential diagnosis of glaucoma and MS.


Assuntos
Pressão Intraocular , Esclerose Múltipla , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/complicações , Estudos Prospectivos , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Pessoa de Meia-Idade , Adulto , Pressão Intraocular/fisiologia , Glaucoma de Ângulo Aberto/diagnóstico , Campos Visuais/fisiologia , Neurite Óptica/diagnóstico
4.
Am J Ophthalmol ; 259: 7-14, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38708401

RESUMO

Purpose: To evaluate the diagnostic accuracy of retinal nerve fiber layer thickness (RNFLT) by spectral-domain optical coherence tomography (OCT) in primary open-angle glaucoma (POAG) in eyes of African (AD) and European descent (ED). Design: Comparative diagnostic accuracy analysis by race. Participants: 379 healthy eyes (125 AD and 254 ED) and 442 glaucomatous eyes (226 AD and 216 ED) from the Diagnostic Innovations in Glaucoma Study and the African Descent and Glaucoma Evaluation Study. Methods: Spectralis (Heidelberg Engineering GmbH) and Cirrus (Carl Zeiss Meditec) OCT scans were taken within one year from each other. Main Outcome Measures: Diagnostic accuracy of RNFLT measurements. Results: Diagnostic accuracy for Spectralis-RNFLT was significantly lower in eyes of AD compared to those of ED (area under the receiver operating curve [AUROC]: 0.85 and 0.91, respectively, P=0.04). Results for Cirrus-RNFLT were similar but did not reach statistical significance (AUROC: 0.86 and 0.90 in AD and ED, respectively, P =0.33). Adjustments for age, central corneal thickness, axial length, disc area, visual field mean deviation, and intraocular pressure yielded similar results. Conclusions: OCT-RNFLT has lower diagnostic accuracy in eyes of AD compared to those of ED. This finding was generally robust across two OCT instruments and remained after adjustment for many potential confounders. Further studies are needed to explore the potential sources of this difference.


Assuntos
Glaucoma de Ângulo Aberto , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , População Branca , Humanos , Glaucoma de Ângulo Aberto/etnologia , Glaucoma de Ângulo Aberto/diagnóstico , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Campos Visuais/fisiologia , População Branca/etnologia , Reprodutibilidade dos Testes , Idoso , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etnologia , Negro ou Afro-Americano/etnologia , Área Sob a Curva , Sensibilidade e Especificidade
5.
Sci Rep ; 14(1): 8889, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632299

RESUMO

We aimed to investigate the changes in cupping in chiasmal lesion optic neuropathy (chON) compared to baseline optic disc and glaucoma. We used a novel study design to enroll patients who had fundus photographs incidentally taken during routine health check-ups prior to the onset of optic neuropathy. In 31 eyes (21 patients) with chON and 33 eyes (30 patients) with glaucoma, we investigated the change in cup-to-disc (C/D) area from the baseline to overt cupping using flicker analysis. Compared to the baseline, 23 eyes (74.2%) had increased cup size and 3 (9.7%) had vascular configuration changes in the chONgroup; in contrast, all glaucoma eyes exhibited changes in cup size and vascular configuration. The increase in C/D area ratio was significantly smaller in chON (0.04 ± 0.04) compared to glaucoma (0.10 ± 0.04, P < 0.001); the minimum residual neuroretinal rim width showed a more pronounced difference (29.7 ± 8.2% vs 7.1 ± 3.9%, P < 0.001). The changes distributed predominantly towards the nasal direction in chON, contrasting the changes to the arcuate fibers in glaucoma. In conclusion, our results provide the first longitudinal evidence of true pathological cupping in chONcompared to photographically disease-free baseline. The marked difference in the residual minimum rim width reaffirms the importance of rim obliteration in the differential diagnosis between the two diseases.


Assuntos
Glaucoma , Disco Óptico , Doenças do Nervo Óptico , Humanos , Disco Óptico/patologia , Glaucoma/patologia , Doenças do Nervo Óptico/patologia , Quiasma Óptico/patologia , Fundo de Olho , Pressão Intraocular
6.
Klin Monbl Augenheilkd ; 241(4): 562-570, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38653313

RESUMO

PURPOSE: Proof of concept of ex vivo retinal vessel diameter measurements in human postmortem eyes. METHODS: En face near-infrared (IR) images and optical coherence tomography (OCT) of the optic nerve head (ONH) were captured ex vivo with a Heidelberg Engineering Spectralis (Spectralis, version 7.0.4, Image Capture Module, version 1.2.4, Heidelberg Heidelberg, Germany) device, using a custom-made eye chamber holding and positioning the eyes during the image process. Thirty-two formaldehyde-fixated eyes of 16 patients were imaged. In the IR images, two independent graders measured retinal vessel diameters at the intersection of a drawn circle centered on the ONH with diameters of 2.0 mm and 3.4 mm, respectively. The anatomically corresponding measurements between both graders were statistically analyzed using a Wilcoxon signed-rank test. RESULTS: A total of 246 matched measurements of both graders were analyzed across all 32 imaged eyes. Statistically significant differences between the graders were found for arterioles at 2 mm from the ONH. The other measurements did not show statistically significant intergrader differences. The mean values for arteriole diameters were 72.2 µm at 2.0 mm and 61.5 µm at 3.4 mm for grader 1, and 66.4 µm at 2.0 mm and 63.2 µm at 3.4 mm for grader 2. The mean diameter for venules were 75.5 µm at 2.0 mm and 79.3 µm at 3.4 mm for grader 1, and 67.4 µm at 2 mm and 79.1 µm at 3.4 mm for grader 2. CONCLUSION: To the best of our knowledge, this is the first study to present IR image-based retinal vessel diameters in ex vivo postmortem eyes. Retinal IR/OCT imaging is possible, and measurements are reproducible in formaldehyde-fixated human eyes. Fixation artefacts result in lower image quality, and this can impose challenges in correctly detecting, classifying, and measuring retinal vessels.


Assuntos
Disco Óptico , Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Feminino , Masculino , Disco Óptico/diagnóstico por imagem , Disco Óptico/irrigação sanguínea , Disco Óptico/patologia , Idoso , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Idoso de 80 Anos ou mais , Autopsia/métodos , Cadáver
7.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38626931

RESUMO

OBJECTIVE: To investigate the characteristics of beta parapapillary atrophy (ß-PPA) in patients with primary angle-closure suspect (PACS). METHODS AND ANALYSIS: In total, 215 and 259 eyes with PACS and non-PACS (NPACS), respectively, were enrolled in this observational, cross-sectional study. Stereoscopic fundus and optical coherence tomography images were used to characterise ß-PPA; the former was also used to measure the major ß-PPA parameters. Univariate and multiple logistic regression analyses were used to identify the factors correlated with the presence of ß-PPA and with ß-PPA parameters. RESULTS: The ß-PPA occurrence rates were 48.80% and 44.40% in the PACS and NPACS groups, respectively, with no significant difference between groups. Compared with that in the NPACS group, the ß-PPA area was significantly larger (p=0.005) in the PACS group, but the angular extent and maximum radial length did not differ between groups (p=0.110 and 0.657, respectively) after adjusting for age and axial length. The presence of ß-PPA was associated with older age (OR 1.057, 95% CI 1.028 to 1.088, p<0.001) and larger disc area (OR 1.716, 95% CI 1.170 to 2.517, p=0.006). A larger ß-PPA area was associated with older age (p=0.014), greater vertical cup-to-disc ratio (p=0.028), larger disc area (p<0.001) and PACS diagnosis (p=0.035). CONCLUSION: 48.80% of participants with PACS had ß-PPA, which is slightly larger than NPACS. The area of ß-PPA was larger in PACS, while the angular extent and maximum radial length did not differ between groups.


Assuntos
Oftalmopatias Hereditárias , Glaucoma de Ângulo Aberto , Atrofia Óptica , Disco Óptico , Humanos , Disco Óptico/patologia , Glaucoma de Ângulo Aberto/complicações , Atrofia Óptica/complicações , Estudos Transversais , Pressão Intraocular , Campos Visuais , Atrofia/complicações
8.
BMC Ophthalmol ; 24(1): 185, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654214

RESUMO

PURPOSE: The present study tested the hypothesis that repeated anti-VEGF injections are associated with reduced retinal nerve fiber layer (RNFL) and minimum rim width (MRW) of the optic nerve head. PATIENTS AND METHODS: Sixty-six patients with a history of intravitreal injections due to neovascular age-related macular degeneration were included. RNFL and MRW were measured using optical coherence tomography (Spectralis OCT, Heidelberg Engineering, Heidelberg, Germany). RESULTS: Mean global RNFL was 90.62 µm and both RNFL as well as MRW significantly decreased with advanced age (p = 0.005 and p = 0.019, respectively). Correlating for the number of injections, no significant impact on RNFL was found globally (p = 0.642) or in any of the sectors. In contrast, however, global MRW was significantly reduced with increasing numbers of intravitreal injections (p = 0.012). The same holds true when adjusted for the confounding factor age (RNFL p = 0.566 and MRW p = 0.023). CONCLUSION: Our study shows that repeated intravitreal injections due to choroidal neovascularization seem to have a deleterious effect on MRW but not on RNFL. This suggests that MRW is a more sensitive marker than RNFL for evaluating the effect of frequent intravitreal injections on the optic nerve head since it seems to be the first structure affected.


Assuntos
Inibidores da Angiogênese , Injeções Intravítreas , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Estudos Transversais , Masculino , Feminino , Idoso , Tomografia de Coerência Óptica/métodos , Inibidores da Angiogênese/administração & dosagem , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Idoso de 80 Anos ou mais , Disco Óptico/patologia , Pessoa de Meia-Idade , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Degeneração Macular Exsudativa/tratamento farmacológico , Degeneração Macular Exsudativa/diagnóstico , Acuidade Visual , Ranibizumab/administração & dosagem , Bevacizumab/administração & dosagem
9.
J Neuroophthalmol ; 44(2): 172-177, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38526582

RESUMO

BACKGROUND: Myelin oligodendrocyte glycoprotein antibody disease (MOGAD) is a demyelinating disorder that most commonly presents with optic neuritis (ON) and affects children more often than adults. We report 8 pediatric patients with MOG-associated ON and characterize focal optical coherence tomography (OCT) abnormalities over time that help distinguish this condition from the trajectories of other demyelinating disorders. These OCT findings are examined in the context of longitudinal visual function testing. METHODS: This is a retrospective case series of 8 pediatric patients with MOG-associated ON who were referred for neuro-ophthalmic evaluation. Longitudinal data for demographics, clinical history, physical examination, and OCT obtained in the course of clinical evaluations were collected through retrospective medical record review. RESULTS: Patients demonstrated acute peripapillary retinal nerve fiber layer (RNFL) thickening in one or both eyes, consistent with optic disc swelling. This was followed by steady patterns of average RNFL thinning, with 9 of 16 eyes reaching significantly low RNFL thickness using OCT platform reference databases ( P < 0.01), accompanied by paradoxical recovery of high-contrast visual acuity (HCVA) in every patient. There was no correlation between HCVA and any OCT measures, although contrast sensitivity (CS) was associated with global thickness, PMB thickness, and nasal/temporal (N/T) ratio, and color vision was associated with PMB thickness. There was a lower global and papillomacular bundle (PMB) thickness ( P < 0.01) in clinically affected eyes compared with unaffected eyes. There was also a significantly higher N:T ratio in clinically affected eyes compared with unaffected eyes in the acute MOG-ON setting ( P = 0.03), but not in the long-term setting. CONCLUSIONS: MOG shows a pattern of prominent retinal atrophy, as demonstrated by global RNFL thinning, with remarkable preservation of HCVA but remaining deficits in CS and color vision. These tests may be better clinical markers of vision changes secondary to MOG-ON. Of the OCT parameters measured, PMB thickness demonstrated the most consistent correlation between structural and functional measures. Thus, it may be a more sensitive marker of clinically significant retinal atrophy in MOG-ON. The N:T ratio in acute clinically affected MOG-ON eyes in our study was higher than the N:T ratio of neuromyelitis optica (NMO)-ON eyes and similar to the N:T ratio in multiple sclerosis (MS)-ON eyes as presented in the prior literature. Therefore, MOG may share a more similar pathophysiology to MS compared with NMO.


Assuntos
Glicoproteína Mielina-Oligodendrócito , Neurite Óptica , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Acuidade Visual , Humanos , Glicoproteína Mielina-Oligodendrócito/imunologia , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Estudos Retrospectivos , Neurite Óptica/diagnóstico , Neurite Óptica/fisiopatologia , Neurite Óptica/imunologia , Criança , Acuidade Visual/fisiologia , Adolescente , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Autoanticorpos/sangue , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Sensibilidades de Contraste/fisiologia
10.
Mol Med Rep ; 29(5)2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38516770

RESUMO

Glaucoma is a group of progressive optic nerve disorders characterized by the loss of retinal ganglion cells, a thinner retinal nerve fibre layer and cupping of the optic disk. Apoptosis is a physiological cell death process regulated by genes and plays a crucial role in maintaining tissue homeostasis, ensuring the natural development and immune defence of organisms. Apoptosis has been associated with glaucoma and inhibiting apoptosis by activating phosphatidylinositol 3-kinase­protein kinase B or other medicines can rescue pathological changes in glaucoma. Due to the complex crosstalk of apoptosis pathways, the pathophysiological mechanism of apoptosis in glaucoma needs to be fully elucidated. The present review aimed to discuss the mechanism of cell apoptosis in glaucoma, improve the understanding of the pathophysiology of glaucoma, summarize new directions for the treatment of glaucoma and lay the foundation for new treatment strategies for glaucoma.


Assuntos
Glaucoma , Disco Óptico , Doenças do Nervo Óptico , Humanos , Glaucoma/genética , Disco Óptico/patologia , Doenças do Nervo Óptico/complicações , Doenças do Nervo Óptico/patologia , Apoptose , Morte Celular
11.
Sci Rep ; 14(1): 5079, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429319

RESUMO

The differential diagnosis for optic atrophy can be challenging and requires expensive, time-consuming ancillary testing to determine the cause. While Leber's hereditary optic neuropathy (LHON) and optic neuritis (ON) are both clinically significant causes for optic atrophy, both relatively rare in the general population, contributing to limitations in obtaining large imaging datasets. This study therefore aims to develop a deep learning (DL) model based on small datasets that could distinguish the cause of optic disc atrophy using only fundus photography. We retrospectively reviewed fundus photographs of 120 normal eyes, 30 eyes (15 patients) with genetically-confirmed LHON, and 30 eyes (26 patients) with ON. Images were split into a training dataset and a test dataset and used for model training with ResNet-18. To visualize the critical regions in retinal photographs that are highly associated with disease prediction, Gradient-Weighted Class Activation Map (Grad-CAM) was used to generate image-level attention heat maps and to enhance the interpretability of the DL system. In the 3-class classification of normal, LHON, and ON, the area under the receiver operating characteristic curve (AUROC) was 1.0 for normal, 0.988 for LHON, and 0.990 for ON, clearly differentiating each class from the others with an overall total accuracy of 0.93. Specifically, when distinguishing between normal and disease cases, the precision, recall, and F1 scores were perfect at 1.0. Furthermore, in the differentiation of LHON from other conditions, ON from others, and between LHON and ON, we consistently observed precision, recall, and F1 scores of 0.8. The model performance was maintained until only 10% of the pixel values of the image, identified as important by Grad-CAM, were preserved and the rest were masked, followed by retraining and evaluation.


Assuntos
Aprendizado Profundo , Atrofia Óptica Hereditária de Leber , Disco Óptico , Neurite Óptica , Humanos , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Estudos Retrospectivos , Atrofia Óptica Hereditária de Leber/patologia , Neurite Óptica/patologia , Fotografação , Atrofia/patologia
12.
Comput Biol Med ; 172: 108281, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38503096

RESUMO

BACKGROUND AND OBJECTIVE: The prevalence of myopia and high myopia is increasing globally, underscoring the growing importance of diagnosing high myopia-related pathologies. While existing image segmentation models, such as U-Net, UNet++, ResU-Net, and TransUNet, have achieved significant success in medical image segmentation, they still face challenges when dealing with ultra-widefield (UWF) fundus images. This study introduces a novel automatic segmentation algorithm for the optic disc and peripapillary atrophy (PPA) based on UWF fundus images, aimed at assisting ophthalmologists in more accurately diagnosing high myopia-related diseases. METHODS: In this study, we developed a segmentation model leveraging a Transformer-based network structure, complemented by atrous convolution and selective boundary aggregation modules, to elevate the accuracy of segmenting the optic disc and PPA in UWF photography. The atrous convolution module adeptly manages multi-scale features, catering to the variances in target sizes and expanding the deep network's receptive field. Concurrently, the incorporation of the selective boundary aggregation module in the skip connections of the model significantly improves the differentiation of boundary information between segmentation targets. Moreover, the comparison of our proposed algorithm with classical segmentation models like U-Net, UNet++, ResU-Net, and TransUNet highlights its considerable advantages in processing UWF photographs. RESULTS: The experimental results show that, compared to the other four models, our algorithm demonstrates substantial improvements in segmenting the optic disc and PPA in UWF photographs. In PPA segmentation, our algorithm improves by 0.8% in Dice, 1.8% in sensitivity, and 1.3% in intersection over union (IOU). In optic disc segmentation, our algorithm improves by 0.3% in Dice, 0.6% in precision, and 0.4% in IOU. CONCLUSION: Our proposed method improves the segmentation accuracy of PPA and optic disks based on UWF photographs, which is valuable for diagnosing high myopia-related diseases in ophthalmology clinics.


Assuntos
Miopia , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Fundo de Olho , Algoritmos , Miopia/diagnóstico , Miopia/patologia , Atrofia/patologia , Processamento de Imagem Assistida por Computador
13.
Am J Ophthalmol ; 262: 141-152, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38354971

RESUMO

PURPOSE: Identifying glaucoma patients at high risk of progression based on widely available structural data is an unmet task in clinical practice. We test the hypothesis that baseline or serial structural measures can predict visual field (VF) progression with deep learning (DL). DESIGN: Development of a DL algorithm to predict VF progression. METHODS: 3,079 eyes (1,765 patients) with various types of glaucoma and ≥5 VFs, and ≥3 years of follow-up from a tertiary academic center were included. Serial VF mean deviation (MD) rates of change were estimated with linear-regression. VF progression was defined as negative MD slope with p<0.05. A Siamese Neural Network with ResNet-152 backbone pre-trained on ImageNet was designed to predict VF progression using serial optic-disc photographs (ODP), and baseline retinal nerve fiber layer (RNFL) thickness. We tested the model on a separate dataset (427 eyes) with RNFL data from different OCT. The Main Outcome Measure was Area under ROC curve (AUC). RESULTS: Baseline average (SD) MD was 3.4 (4.9)dB. VF progression was detected in 900 eyes (29%). AUC (95% CI) for model incorporating baseline ODP and RNFL thickness was 0.813 (0.757-0.869). After adding the second and third ODPs, AUC increased to 0.860 and 0.894, respectively (p<0.027). This model also had highest AUC (0.911) for predicting fast progression (MD rate <1.0 dB/year). Model's performance was similar when applied to second dataset using RNFL data from another OCT device (AUC=0.893; 0.837-0.948). CONCLUSIONS: DL model predicted VF progression with clinically relevant accuracy using baseline RNFL thickness and serial ODPs and can be implemented as a clinical tool after further validation.


Assuntos
Aprendizado Profundo , Progressão da Doença , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Feminino , Masculino , Fibras Nervosas/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Idoso , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Seguimentos , Algoritmos , Transtornos da Visão/fisiopatologia , Transtornos da Visão/diagnóstico , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia , Estudos Retrospectivos , Área Sob a Curva , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico
14.
Sci Rep ; 14(1): 4492, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38396059

RESUMO

Patients with chronic daily headaches (CDH) are often a diagnostic challenge and frequently undergo neuroimaging. One common underlying cause of CDH is idiopathic intracranial hypertension (IIH). However, certain neuroimaging abnormalities that suggest IIH, such as optic nerve sheath diameters (ONSD), pituitary gland height, and venous sinus diameter, require interpretation due to the absence of established normative values. Notably, intracranial pressure is known to varies with age, sex and weight, further complicating the determination of objectively abnormal findings within a specific patient group. This study aims to assist clinical neuroradiologists in differentiating neuroimaging results in CDH by providing weight-adjusted normative values for imaging characteristics of IIH. In addition to age and BMI we here assessed 1924 population-based T1-weighted MRI datasets of healthy participants for relevant MRI aspects of IIH. Association to BMI was analyzed using linear/logistic regression controlled for age and stratified for sex. ONSD was 4.3 mm [2.8; 5.9]/4.6 mm [3.6; 5.7] and diameter of transverse sinus was 4.67 mm [1.6; 6.5]/4.45 mm [3.0; 7.9]. Height of pituitary gland was 5.1 mm [2.2;8.1]/4.6 mm [1.9;7.1] for female and male respectively. Values generally varied with BMI with regression slopes spanning 0.0001 to 0.05 and were therefor presented as normative values stratified by BMI. Protrusion of ocular papilla, empty sella and transverse sinus occlusion were rare in total. Our data show an association between BMI and commonly used MRI features for diagnosing IIH. We provide categorized normative BMI values for ONSD, pituitary gland height, and transverse sinus diameter. This distinction helps objectively identify potential IIH indicators compared to regular population norms, enhancing diagnostic accuracy for suspected IIH patients. Notably, optic nerve head protrusion, empty sella, and transverse sinus occlusion are rare in healthy individuals, solidifying their importance as imaging markers regardless of BMI.


Assuntos
Disco Óptico , Pseudotumor Cerebral , Humanos , Masculino , Feminino , Pseudotumor Cerebral/diagnóstico por imagem , Valores de Referência , Imageamento por Ressonância Magnética/métodos , Neuroimagem , Disco Óptico/patologia
15.
Graefes Arch Clin Exp Ophthalmol ; 262(6): 1899-1910, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38240777

RESUMO

BACKGROUND/AIM: The aim of this paper is to compare retinal nerve fiber layer thickness (RNFL) and Bruch's membrane opening-based minimum rim width (BMO-MRW) in terms of their performance in detecting early and moderate/advanced glaucoma using receiver operating characteristics (ROC) analysis and the classification using the 5th percentile as a cut-off. METHODS: One hundred eyes from 100 patients with early glaucoma (mean deviation (MD): < -5.0 dB) and 100 eyes from 100 patients with moderate/advanced glaucoma (MD: > -5.0 dB) were carefully matched to healthy controls based on optic disc size. Then, the dataset was divided, based on the 50th percentile of the measured Bruch's membrane opening area (BMO-A), into small (BMO-A < 1.95 mm2) and large optic discs (BMO-A > 1.95 mm2). Finally, the discriminative performance of BMO-MRW and RNFL between glaucoma and controls using ROC analysis and the manufacturer's classification based on the 5th percentile was analyzed. RESULTS: In discriminating between glaucoma and matched healthy controls, global BMO-MRW and global RNFL thickness had comparable areas under the ROC curve for eyes with early glaucoma and both small BMO-As (ROC ± confidence interval [CI] 0.91 [0.87 to 0.95] and 0.88 [0.83 to 0.93]) and large BMO-As (0.86 [0.82 to 0.92] and 0.84 [0.79 to 0.90]), as well as in moderate/advanced glaucoma with small BMO-As (0.99 [0.98 to 1.00] and 0.97 [0.95 to 1.00]) and large BMO-As (0.94 [0.91 to 0.98] and 0.97 [0.94 to 1.00]). Using the calculated 5th percentile as a threshold value, the sensitivities for the detection of early and moderate/advanced glaucoma were comparable for BMO-MRW and RNFL in eyes with small optic discs (early glaucoma: fifty-two percent and 61%; moderate/advanced glaucoma: ninety-one percent and 92%). In eyes with large optic discs, the sensitivity of BMO-MRW was inferior to that of RNFL for both early (38% versus 51%) and moderate/advanced (80% versus 91%) glaucoma. CONCLUSION: Based on an ROC analysis, the discriminative performance of BMO-MRW and RNFL between patients with early and moderate/advanced glaucoma and a healthy control group matched based on optic disc size is comparable in eyes with BMO-As smaller and larger 1.95 mm2. Using a classification based on the 5th percentile, as used in clinical practice, RNFL is shown to be superior to BMO-MRW regarding sensitivity in glaucoma detection with large optic discs. This study underscores the importance of RNFL imaging and measurement in the diagnostic evaluation of glaucoma, especially in cases of large optic discs.


Assuntos
Lâmina Basilar da Corioide , Pressão Intraocular , Fibras Nervosas , Disco Óptico , Curva ROC , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Disco Óptico/patologia , Lâmina Basilar da Corioide/patologia , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Feminino , Masculino , Tomografia de Coerência Óptica/métodos , Campos Visuais/fisiologia , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Idoso , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Estudos Retrospectivos , Reprodutibilidade dos Testes
16.
Sci Rep ; 14(1): 498, 2024 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-38177229

RESUMO

We aimed to determine the effect of optic disc tilt on deep learning-based optic disc classification. A total of 2507 fundus photographs were acquired from 2236 eyes of 1809 subjects (mean age of 46 years; 53% men). Among all photographs, 1010 (40.3%) had tilted optic discs. Image annotation was performed to label pathologic changes of the optic disc (normal, glaucomatous optic disc changes, disc swelling, and disc pallor). Deep learning-based classification modeling was implemented to develop optic-disc appearance classification models with the photographs of all subjects and those with and without tilted optic discs. Regardless of deep learning algorithms, the classification models showed better overall performance when developed based on data from subjects with non-tilted discs (AUC, 0.988 ± 0.002, 0.991 ± 0.003, and 0.986 ± 0.003 for VGG16, VGG19, and DenseNet121, respectively) than when developed based on data with tilted discs (AUC, 0.924 ± 0.046, 0.928 ± 0.017, and 0.935 ± 0.008). In classification of each pathologic change, non-tilted disc models had better sensitivity and specificity than the tilted disc models. The optic disc appearance classification models developed based all-subject data demonstrated lower accuracy in patients with the appearance of tilted discs than in those with non-tilted discs. Our findings suggested the need to identify and adjust for the effect of optic disc tilt on the optic disc classification algorithm in future development.


Assuntos
Aprendizado Profundo , Anormalidades do Olho , Glaucoma , Disco Óptico , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Disco Óptico/diagnóstico por imagem , Disco Óptico/patologia , Tomografia de Coerência Óptica/métodos , Anormalidades do Olho/patologia , Glaucoma/diagnóstico , Glaucoma/patologia
17.
Prog Retin Eye Res ; 99: 101246, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262557

RESUMO

Due to the increasing prevalence of high myopia around the world, structural and functional damages to the optic nerve in high myopia has recently attracted much attention. Evidence has shown that high myopia is related to the development of glaucomatous or glaucoma-like optic neuropathy, and that both have many common features. These similarities often pose a diagnostic challenge that will affect the future management of glaucoma suspects in high myopia. In this review, we summarize similarities and differences in optic neuropathy arising from non-pathologic high myopia and glaucoma by considering their respective structural and functional characteristics on fundus photography, optical coherence tomography scanning, and visual field tests. These features may also help to distinguish the underlying mechanisms of the optic neuropathies and to determine management strategies for patients with high myopia and glaucoma.


Assuntos
Glaucoma , Miopia , Disco Óptico , Doenças do Nervo Óptico , Humanos , Disco Óptico/patologia , Pressão Intraocular , Glaucoma/diagnóstico , Doenças do Nervo Óptico/patologia , Miopia/complicações , Miopia/diagnóstico , Tomografia de Coerência Óptica/métodos
18.
Ophthalmic Res ; 67(1): 154-171, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38262372

RESUMO

INTRODUCTION: Anterior ischemic optic neuropathy (AION) can mimic glaucoma and consequently cause difficulties in differential diagnosis. The purpose of this paper was to summarize differences in diagnostic tests that can help perform a correct diagnosis. METHODS: The search strategy was performed according to the PRISMA 2009 guidelines, and four databases were used: MEDLINE, Embase, Web of Science, and Cochrane. Totally, 772 references were eligible; 39 were included after screening with respect to inclusion criteria that included English language and published in the 20 years before search date. RESULTS: Ninety percent (n = 35) of included studies used optical coherence tomography (OCT). Glaucomatous eyes had a significantly greater cup area, volume and depth, cup-to-disk ratio, a lower rim volume and area, and a thinner Bruch's membrane opening-minimum rim width. Retinal nerve fiber layer (RNFL) thinning in glaucomatous eyes occurred primarily at the superotemporal, inferotemporal, and inferonasal sectors, while AION eyes demonstrated mostly superonasal thinning. Glaucoma eyes showed greater macular ganglion cell layer thickness, except at the inferotemporal sector. OCT angiography measurements demonstrated a significant decrease in superficial and deep macular vessel density (VD) in glaucoma compared to AION with similar degree of visual field damage; the parapapillary choroidal VD was spared in AION eyes compared to glaucomatous eyes. CONCLUSION: By use of OCT imaging, optic nerve head parameters seem most informative to distinguish between glaucoma and AION. Although both diseases affect the RNFL thickness, it seems to do so in different sectors. Differences in structure and vascularity of the macula can also help in making the differential diagnosis.


Assuntos
Glaucoma , Fibras Nervosas , Disco Óptico , Neuropatia Óptica Isquêmica , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Neuropatia Óptica Isquêmica/diagnóstico , Diagnóstico Diferencial , Tomografia de Coerência Óptica/métodos , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Disco Óptico/patologia , Disco Óptico/diagnóstico por imagem , Disco Óptico/irrigação sanguínea , Glaucoma/diagnóstico , Campos Visuais/fisiologia , Pressão Intraocular/fisiologia
19.
Br J Ophthalmol ; 108(4): 607-612, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-37055157

RESUMO

AIM: To evaluate the role of papillary vitreous detachment in the pathogenesis of non-arteritic anterior ischaemic optic neuropathy (NAION) by comparing the features of vitreopapillary interface between NAION patients and normal individuals. METHODS: This study included 22 acute NAION patients (25 eyes), 21 non-acute NAION patients (23 eyes) and 23 normal individuals (34 eyes). All study participants underwent swept-source optical coherence tomography to assess the vitreopapillary interface, peripapillary wrinkles and peripapillary superficial vessel protrusion. The statistical correlations between peripapillary superficial vessel protrusion measurements and NAION were analysed. Two NAION patients underwent standard pars plana vitrectomy. RESULTS: Incomplete papillary vitreous detachment was noted in all acute NAION patients. The prevalence of peripapillary wrinkles was 68% (17/25), 30% (7/23) and 0% (0/34), and the prevalence of peripapillary superficial vessel protrusion was 44% (11/25), 91% (21/23) and 0% (0/34) in the acute, non-acute NAION and control groups, respectively. The prevalence of peripapillary superficial vessel protrusion was 88.9% in the eyes without retinal nerve fibre layer thinning. Furthermore, the number of peripapillary superficial vessel protrusions in the superior quadrant was significantly higher than that in the other quadrants in eyes with NAION, consistent with the more damaged visual field defect regions. Peripapillary wrinkles and visual field defects in two patients with NAION were significantly attenuated within 1 week and 1 month after the release of vitreous connections, respectively. CONCLUSION: Peripapillary wrinkles and superficial vessel protrusion may be signs of papillary vitreous detachment-related traction in NAION. Papillary vitreous detachment may play an important role in NAION pathogenesis.


Assuntos
Disco Óptico , Neuropatia Óptica Isquêmica , Descolamento do Vítreo , Humanos , Neuropatia Óptica Isquêmica/diagnóstico , Neuropatia Óptica Isquêmica/etiologia , Disco Óptico/patologia , Descolamento do Vítreo/complicações , Descolamento do Vítreo/diagnóstico , Descolamento do Vítreo/patologia , Testes de Campo Visual , Tomografia de Coerência Óptica/métodos
20.
Acta Ophthalmol ; 102(1): 15-24, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37144704

RESUMO

Optic disc drusen (ODD) are calcium-containing deposits in the optic nerve head, capable of causing visual field defects and sudden visual loss. The underlying pathophysiology remains inadequately understood and treatment options are missing. In this paper, we systematically reviewed prevalence studies of ODD in non-selected populations to provide an overview of its prevalence, conducted meta-analyses to determine modality-specific prevalence estimates and performed a forecasting study to estimate current and future global population number of individuals with ODD. We searched 11 literature databases on 25 October 2022 for prevalence studies of ODD in non-selected populations. Eight eligible studies provided data from a total of 27 463 individuals. Prevalence estimates were stratified according to diagnostic modalities: ophthalmoscopy 0.37% (95% CI: 0.10-0.95%), fundus photography 0.12% (95% CI: 0.03-0.24%), spectral domain optical coherence tomography with enhanced depth imaging 2.21% (95% CI: 1.25-3.42%) and histopathology 1.82% (95% CI: 1.32-2.38%). Using histopathology-based summary prevalence estimate, we forecast 145 million individuals with ODD currently, a number expected to increase further due to world population growth. These numbers underscore the importance of including ODD in health education and highlight the necessity of continuing research in ODD.


Assuntos
Drusas do Disco Óptico , Disco Óptico , Humanos , Disco Óptico/patologia , Drusas do Disco Óptico/diagnóstico , Drusas do Disco Óptico/epidemiologia , Drusas do Disco Óptico/etiologia , Prevalência , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA