Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 1004-1014, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38577939

RESUMO

INTRODUCTION: Bicuspid aortic valve (BAV) stenosis is a complex anatomical scenario for transcatheter aortic valve implantation (TAVI). Favorable short-term clinical outcomes have been reported with TAVI in this setting, but long-term data are scarce. METHODS: We retrospectively included, in a single-center registry, patients with BAV stenosis who underwent TAVI before 2020. We compared patients treated with self-expanding valves (SEV) versus balloon-expandable valves (BEV). The primary endpoint was a composite of all-cause mortality, stroke and need for aortic valve (AV) reintervention at 3 years. Secondary endpoints included each component of the primary endpoint, cardiovascular mortality, permanent pacemaker implantation (PPI) rate, mean gradient and ≥moderate paravalvular leak (PVL) rate. RESULTS: A total of 150 consecutive patients (SEV = 83, BEV = 67) were included. No significant differences were reported between SEV and BEV groups for the primary composite endpoint (SEV 35.9% vs. BEV 32%, p = 0.66), neither for clinical secondary endpoints (all-cause mortality SEV 28.1% vs. BEV 28%, p = 0.988; cardiovascular mortality SEV 14.1% vs. BEV 20%, p = 0.399; stroke SEV 12.5% vs. BEV 6%, p = 0.342; need for AV reintervention SEV 0% vs. BEV 0%; PPI SEV 28.1% vs. BEV 24%, p = 0.620). A lower mean gradient persisted up to 3 years in the SEV group (SEV 8.8 ± 3.8 mmHg vs. BEV 10.7 ± 3.2 mmHg, p = 0.063), while no significant difference was found in the rate of ≥ moderate PVL (SEV 3/30 vs. BEV 0/25, p = 0.242). CONCLUSIONS: In this single center registry, we observed favorable 3-year clinical outcomes in nonselected BAV patients treated with different generation devices, without significant differences between patients receiving SEV or BEV.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Estudos Retrospectivos , Resultado do Tratamento , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Fatores de Tempo , Idoso , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Recuperação de Função Fisiológica , Hemodinâmica , Medição de Risco
2.
Cardiovasc Revasc Med ; 63: 16-20, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38233251

RESUMO

BACKGROUND: There continues to be debate regarding the superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) in patients with bicuspid aortic valves (BAV). We aimed to compare outcomes during readmissions in elderly patients with BAV who underwent SAVR or TAVR. METHODS: Patients 65 years or older with BAV who underwent TAVR or isolated SAVR were identified using the National Readmission Database from 2012 through 2018. We compared outcomes during readmissions within 90 days after discharge from the index surgery. Propensity score matching was performed to adjust the baseline differences. RESULTS: During the study period, 8555 and 1081 elderly patients with BAV underwent SAVR and TAVR, respectively. The number of patients who underwent TAVR went up by 179 % from 2012 to 2018. Propensity score matching yielded 573 patients in each group. A total of 111 (19.4 %) in the SAVR group and 125 (21.8 %) in the TAVR group were readmitted within 90 days after the index surgery (p = .31). The mortality during the readmissions within 90 days was equivalent between the two groups (0.9 % in the SAVR group vs. 3.2 % in the TAVR group, p = .22). However, the median hospital cost was approximately doubled in the TAVR group during the readmission (18,250 dollars vs. 9310 dollars in the SAVR group, p < .001). CONCLUSIONS: Readmission within 90 days was common in both groups. While the mortality during the readmissions after the surgery was equivalent between the two groups, hospital cost was significantly more expensive in the TAVR group.


Assuntos
Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Bases de Dados Factuais , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Readmissão do Paciente , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/economia , Masculino , Feminino , Idoso , Resultado do Tratamento , Fatores de Tempo , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fatores de Risco , Estados Unidos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Implante de Prótese de Valva Cardíaca/economia , Estudos Retrospectivos , Fatores Etários , Medição de Risco , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Complicações Pós-Operatórias/etiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia
3.
Ann Thorac Surg ; 113(2): 527-534, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33811890

RESUMO

BACKGROUND: Enlargement of the sinus of Valsalva (SOV) is common in patients with bicuspid aortic valves (BAVs), and management at the time of aortic valve replacement (AVR) and concomitant ascending aorta replacement/repair is controversial. METHODS: Between January 2000 and July 2017, 400 patients with BAVs underwent AVR and concomitant ascending aorta repair (graft replacement, 79%; aortoplasty, 21%). To assess the impact of the initial SOV dimension on future dilatation and outcomes, patients were stratified into 2 groups: SOV of less than 40 mm (SOV<40 mm) (n = 209) and SOV of 40 mm or larger (SOV≥40 mm) (n = 191). RESULTS: Patients with SOV≥40 mm were older and more often male. At a median follow-up of 8.1 years (interquartile range, 7.4-9.1 years), 6 patients underwent reoperations on the ascending or sinus portion of the aorta due to aneurysmal dilatation, and enlargement of the sinus was the primary indication for operation in 1 patient. Adjusted analysis showed that baseline SOV and SOV dimension over time were not associated with late outcomes. A gradual increase in SOV diameter over time was identified (P = .004). Patients with smaller baseline SOV diameters showed an initial early decrease in diameter, followed by gradual increase, whereas those with larger baseline diameters had a stable early phase, followed by gradual dilatation. CONCLUSIONS: Ascending aorta replacement may lead to an initial remodeling/stabilizing effect on the spared bicuspid aortic root, which is more pronounced in patients with lower SOV diameters. In addition, our data demonstrate that the retained aortic sinuses enlarge slowly, and within the limited follow-up of our study, SOV diameter was not a risk factor for survival or reoperation.


Assuntos
Doença da Válvula Aórtica Bicúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Medição de Risco/métodos , Seio Aórtico/cirurgia , Idoso , Doença da Válvula Aórtica Bicúspide/diagnóstico , Doença da Válvula Aórtica Bicúspide/mortalidade , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Reoperação , Estudos Retrospectivos , Fatores de Risco , Seio Aórtico/diagnóstico por imagem , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
4.
Comput Math Methods Med ; 2021: 3147382, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34956394

RESUMO

OBJECTIVE: Explore the factors affecting the QO of life after transcatheter aortic valve replacement (TAVR) and analyze and evaluate their surgical efficacy and postoperative survival status. METHODS: Through correlation analysis and multiple regression analysis, we predict various clinical characteristics and postoperative quality and predict clinical changes in L postoperative quality. RESULTS: The quality of life of patients with the disease has gradually improved and improved from 6 months after surgery. The differences in the three aspects of its physiological mechanism function, physiological function function, overall health, and vitality are statistically significant (p < 0.05). CONCLUSION: Compared with traditional open-thoracic aortic valve (AV) surgery, TAVR has the significant advantages of smaller surgical incision and less trauma to the patient, which has become one of the reasons why patients are willing to accept it.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/cirurgia , China/epidemiologia , Biologia Computacional , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
5.
Mayo Clin Proc ; 96(3): 648-657, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33673916

RESUMO

OBJECTIVE: To describe the clinical history of patients with a wide age range diagnosed with bicuspid aortic valve (BAV) and no surgical indication and to evaluate the long-term outcome of patients with BAV referred for elective surgery. PATIENTS AND METHODS: Between 2005 and 2017, 350 consecutive patients with no surgical indication (surveillance group, mean age 53±16, 71% men) and 191 with a surgical indication (surgical group, mean age 59±13, 71% men) were prospectively included. Median follow-up was 80 (32 to 115) months. RESULTS: In the surveillance group, the 5-year and 10-year survival rates were 93±1% and 89±2%, respectively, with a relative survival of patients with BAV compared with an age- and sex-matched control population of 98.7%. During follow-up, the cumulative 10-year incidence of aortic valve and aorta surgery was high; of 35±4%, the incidence of native valve infective endocarditis (IE) of 0.2% per patient-year, and no cases of aortic dissection were observed. In the surgical group, the 5-year and 10-year survival rates were 97±1% and 89±3%, respectively, with a relative survival of 99.4% compared with the general population. The incidence of IE was 0.4% per patient-year, and no cases of aortic dissection were observed. CONCLUSION: This regional cohort shows that the 10-year survival rates of patients with BAV and a wide age range, but mostly middle-aged adults, were similar to those of the general population with a very low rate of complications. Adherence to prophylactic surgical indications and younger age might have contributed to this lack of difference.


Assuntos
Doença da Válvula Aórtica Bicúspide/mortalidade , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Adulto , Idoso , Doença da Válvula Aórtica Bicúspide/complicações , Endocardite/mortalidade , Europa (Continente) , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Estudos Prospectivos , Estudos Retrospectivos , Taxa de Sobrevida
6.
Thorac Cardiovasc Surg ; 69(5): 389-395, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31299697

RESUMO

OBJECTIVE: Long-term prognosis of patients with aortic regurgitation (AR) and reduced left ventricular ejection fraction (LVEF) who undergo aortic valve surgery (AVS) is unknown. Due to the congenital origin, bicuspid aortic valve (BAV) morphotype might be associated with a more severe cardiomyopathy. We aimed to evaluate the LVEF recovery after aortic valve replacement (AVR) surgery in patients with AR and reduced preoperative LVEF. METHODS: This retrospective analysis included 1,170 consecutive patients with moderate to severe AR who underwent AVS at our institution between January 2005 and April 2016. Preoperative echocardiography revealed 154 (13%) patients with predominant AR and baseline LVEF < 50%. A total of 60 (39%) patients had a BAV (BAV group), while the remaining 94 (61%) patients had a tricuspid morphotype (tricuspid aortic valve [TAV] group). Follow-up protocol included clinical interview using a structured questionnaire and echocardiographic follow-up. RESULTS: A total of 154 patients (mean age 63.5 ± 12.4 years, 71% male) underwent AVS for AR in the context of reduced LVEF (mean LVEF 42 ± 8%). Fifteen (10%) patients had a severely reduced preoperative LVEF ≤ 30%. Mean STS (Society of Thoracic Surgeons) score was 1.36 ± 1.09%. Mean follow-up was comparable between both the study groups (BAV: 50 ± 40 months vs. TAV: 40 ± 38 months, p = 0.140). A total of 25 (17%) patients died during follow-up. Follow-up echocardiography demonstrated similar rate of postoperatively reduced LVEF in both groups (i.e., 39% BAV patients vs. 43% TAV patients; p = 0.638). Cox's regression analysis showed no significant impact of BAV morphotype (i.e., as compared with TAV) on the postoperative LVEF recovery (odds ratio [OR]: 1.065; p = 0.859). Severe left ventricular (LV) dysfunction at baseline (i.e., LVEF ≤ 30%) was a strong predictor for persistence of reduced LVEF during follow-up (OR: 3.174; 95% confidence interval: 1.517-6.640; p = 0.002). Survival was significantly reduced in patients with persisting LV dysfunction versus those in whom LVEF recovered (log rank: p < 0.001). CONCLUSION: Our study demonstrates that reduced LVEF persists postoperatively in 40 to 45% patients who present with relevant AR and reduced LVEF at baseline. Postoperative LVEF recovery is independent of aortic valve morphotype (i.e., BAV vs. TAV). Severe LV dysfunction (LVEF ≤ 30%) at baseline is a strong predictor for persistence of reduced LVEF in patients with AR and results in significantly reduced long-term survival.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Implante de Prótese de Valva Cardíaca , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Adulto , Idoso , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Bases de Dados Factuais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem
7.
JAMA Cardiol ; 5(12): 1366-1373, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32936224

RESUMO

Importance: Bicuspid aortic valve (BAV) repair has been used in limited cohorts, but its long-term results in a large population are unknown. Objectives: To analyze the long-term stability of BAV repair for survival and the factors associated with repair failure and to evaluate whether a differentiated anatomic repair approach may improve repair stability. Design, Setting, and Participants: In this case series, 1024 patients underwent BAV repair for aortic regurgitation or aneurysm between October 1995 and June 2018, with a mean (SD) follow-up time of 56 (49) months and maximum follow-up of 271 months. Systematic modifications in technique based on anatomic principles were introduced in 2009 and applied for the last 727 patients. Data were acquired prospectively and analyzed retrospectively. Exposures: Repair of BAV with or without concomitant aortic replacement, as well as postoperative clinical and echocardiographic follow-up. Main Outcomes and Measures: Survival and incidence of reoperation or recurrent aortic regurgitation, as well as factors associated with valve repair failure. Results: Among the 1024 patients in the study (920 male [89.8%]; mean [SD] age, 47 [13] years [range, 15-86 years]), the survival rate at 15 years was 82.1%. The cumulative incidence of reoperation was 30.7% (95% CI, 22.7%-38.7%) at 15 years. Cusp calcification (subdistribution hazard ratio, 1.78; 95% CI, 1.14-2.77; P = .01), asymmetric commissural orientation (subdistribution hazard ratio, 1.95; 95% CI, 1.02-3.72; P = .04), and use of a pericardial patch for cusp repair (subdistribution hazard ratio, 5.25; 95% CI, 3.52-7.82; P < .001) were associated with time to reoperation. At 10 years, the incidence of reoperation was significantly reduced among patients who received the anatomic repair concept compared with those who had undergone surgery in the earlier period (8.8% vs 24.6%; P < .001). Conclusions and Relevance: This study suggests that survival after BAV repair is excellent and that a large proportion of BAV repairs will remain stable. Repair stability can be markedly improved by an anatomic repair concept. Cusp calcification and the need for cusp repair using a patch remain the factors most strongly associated with valve failure. In those instances, valve replacement should be preferred.


Assuntos
Doença da Válvula Aórtica Bicúspide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/patologia , Procedimentos Cirúrgicos Cardíacos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
8.
J Am Coll Cardiol ; 76(9): 1018-1030, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32854836

RESUMO

BACKGROUND: Bicuspid aortic stenosis accounts for almost 50% of patients undergoing surgical aortic valve replacement in the younger patients. Expanding the indication of transcatheter aortic valve replacement (TAVR) toward lower-risk and younger populations will lead to increased use of TAVR for patients with bicuspid aortic valve (BAV) stenosis despite the exclusion of bicuspid anatomy in all pivotal clinical trials. OBJECTIVES: This study sought to evaluate the association of BAV morphology and outcomes of TAVR with the new-generation devices. METHODS: Patients with BAV confirmed by central core laboratory computed tomography (CT) analysis were included from the international multicenter BAV TAVR registry. BAV morphology including the number of raphe, calcification grade in raphe, and leaflet calcium volume were assessed with CT analysis in a masked fashion. Primary outcomes were all-cause mortality at 1 and 2 years, and secondary outcomes included 30-day major endpoints and procedural complications. RESULTS: A total of 1,034 CT-confirmed BAV patients with a mean age of 74.7 years and Society of Thoracic Surgeons score of 3.7% underwent TAVR with contemporary devices (n = 740 with Sapien 3; n = 188 with Evolut R/Pro; n = 106 with others). All-cause 30-day, 1-year, and 2-year mortality was 2.0%, 6.7%, and 12.5%, respectively. Multivariable analysis identified calcified raphe and excess leaflet calcification (defined as more than median calcium volume) as independent predictors of 2-year all-cause mortality. Both calcified raphe plus excess leaflet calcification were found in 269 patients (26.0%), and they had significantly higher 2-year all-cause mortality than those with 1 or none of these morphological features (25.7% vs. 9.5% vs. 5.9%; log-rank p < 0.001). Patients with both morphological features had higher rates of aortic root injury (p < 0.001), moderate-to-severe paravalvular regurgitation (p = 0.002), and 30-day mortality (p = 0.016). CONCLUSIONS: Outcomes of TAVR in bicuspid aortic stenosis depend on valve morphology. Calcified raphe and excess leaflet calcification were associated with increased risk of procedural complications and midterm mortality. (Bicuspid Aortic Valve Stenosis Transcatheter Aortic Valve Replacement Registry; NCT03836521).


Assuntos
Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/cirurgia , Internacionalidade , Sistema de Registros , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Mortalidade/tendências , Estudos Prospectivos , Tomografia Computadorizada por Raios X/mortalidade , Tomografia Computadorizada por Raios X/tendências , Resultado do Tratamento
9.
JACC Cardiovasc Interv ; 13(15): 1749-1759, 2020 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-32473890

RESUMO

OBJECTIVES: This study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: TAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves. METHODS: The Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up. RESULTS: Between July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable. CONCLUSIONS: All-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento , Estados Unidos
11.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943783

RESUMO

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
12.
BMJ Mil Health ; 166(3): 167-170, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30429296

RESUMO

Bicuspid aortic valve (BAV) is the most common congenital cardiac malformation. It is an aortopathy and is associated with other congenital heart disease. Although there is no mortality increase with BAV, the natural history increases the risk of aortic valve disease, aortic dilatation and infective endocarditis over the time frame of a full military career. Military service theoretically increases the risk of aortic dilatation and endocarditis in BAV. Conversely, there are some who have BAV who would not suffer any complications during their military career. Currently, potential UK Army recruits undergo personal/family history and physical examination plus an ECG and, although this goes beyond American Heart Association guidelines, it does not screen specifically for BAV. This would necessitate a transthoracic echo for each potential recruit but would be a considerable increase in resources-both time and financial. In addition to the recruitment medical, military personnel undergo frequent medicals, which could identify those who develop significant valvular disease. Those with mild valve disease are at lowest risk of complication. Those with aortic dilatation only remain a concern.


Assuntos
Doença da Válvula Aórtica Bicúspide , Militares , Doenças da Aorta/etiologia , Doença da Válvula Aórtica Bicúspide/complicações , Doença da Válvula Aórtica Bicúspide/epidemiologia , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/patologia , Endocardite Bacteriana/etiologia , Humanos , Fatores de Risco , Reino Unido
13.
Catheter Cardiovasc Interv ; 95(6): 1186-1192, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31483555

RESUMO

OBJECTIVES: To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve. BACKGROUND: Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce. METHODS: We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve. RESULTS: Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%. CONCLUSIONS: Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Canadá , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA