Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
J Emerg Med ; 21(4): 407-9, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11728769

RESUMO

Modern urine beta-human chorionic gonadotropin (HCG) assays that use enzyme-linked immunosorbent assay (ELISA) technology are sensitive and specific for diagnosing pregnancy, both intrauterine and ectopic, and have become indispensable to the practice of Emergency Medicine. A urine HCG test is often relied on by the Emergency Physician as a critical component in the diagnostic regimen of a patient with a possible ectopic pregnancy. We report a case of a false-positive urine beta-HCG test in a patient with a ruptured tubo-ovarian abscess. Though false-positive pregnancy tests with tubo-ovarian abscesses have previously been reported with older methods of HCG detection, we believe that this is the first case where the pregnancy test was the modern ELISA type. The mechanism for the false-positive reaction in this case is unknown, but time may show that the ELISA test kit, like its predecessors, may occasionally give a false-positive reaction in this class of patients.


Assuntos
Abscesso/urina , Doenças dos Anexos/urina , Gonadotropina Coriônica Humana Subunidade beta/urina , Tubas Uterinas , Doenças Ovarianas/urina , Adulto , Reações Falso-Positivas , Feminino , Humanos , Gravidez , Ruptura Espontânea
2.
Ann Acad Med Singap ; 23(3): 311-4, 1994 May.
Artigo em Inglês | MEDLINE | ID: mdl-7944239

RESUMO

A prospective study was made of 105 consecutive patients admitted to one department of obstetrics and gynaecology for surgery for adnexal masses. The objective was to investigate if CA 125 level is measurable in the urine or saliva and to correlate these measurements with serum CA 125 level in patients presenting with adnexal masses. The final diagnosis and grouping of patients for analysis were based on histopathological examination of the adnexal masses. Serum, urine and salivary samples were collected simultaneously from all patients on the morning before surgery. CA 125 levels in each sample were determined in duplicate using Abbott CA 125-E1A monoclonal test kits (Abbott Laboratories, USA). The mean inter-assay variability was 10%. CA 125 was detectable in the serum, urine and saliva from all the patients and the concentration was highest in the saliva and lowest in urine. There were no discernible differences in the distributions of salivary CA 125 concentrations between patients with ovarian malignancies and those with benign ovarian cysts. In contrast, both serum and urinary CA 125 levels were significantly higher in the ovarian cancer group. There was no correlation in CA 125 concentrations between serum and urine, or between serum and saliva. For detection of ovarian malignancies, the sensitivity, specificity, and positive and negative predictive values for serum CA 125 measurement (> or = 35 U/mL) were 88.9%, 79.2%, 27.6% and 98.7 respectively. The corresponding figures for urinary CA 125 measurement (> or = 10 U/mL) were 88.9%, 66.7%, 19.5% and 98.4% respectively.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Doenças dos Anexos/imunologia , Antígeno Ca-125/análise , Saliva/imunologia , Adenocarcinoma/sangue , Adenocarcinoma/imunologia , Adenocarcinoma/urina , Doenças dos Anexos/sangue , Doenças dos Anexos/patologia , Doenças dos Anexos/urina , Adulto , Antígeno Ca-125/sangue , Antígeno Ca-125/urina , Cistadenoma/sangue , Cistadenoma/imunologia , Cistadenoma/urina , Endometriose/sangue , Endometriose/imunologia , Endometriose/urina , Feminino , Humanos , Pessoa de Meia-Idade , Cistos Ovarianos/sangue , Cistos Ovarianos/imunologia , Cistos Ovarianos/patologia , Cistos Ovarianos/urina , Doenças Ovarianas/sangue , Doenças Ovarianas/imunologia , Doenças Ovarianas/patologia , Doenças Ovarianas/urina , Neoplasias Ovarianas/sangue , Neoplasias Ovarianas/imunologia , Neoplasias Ovarianas/patologia , Neoplasias Ovarianas/urina , Estudos Prospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA