Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.801
Filtrar
1.
Mikrochim Acta ; 191(6): 332, 2024 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748375

RESUMO

Nifedipine (NIF), as one of the dihydropyridine calcium channel blockers, is widely used in the treatment of hypertension. However, misuse or ingestion of NIF can result in serious health issues such as myocardial infarction, arrhythmia, stroke, and even death. It is essential to design a reliable and sensitive detection method to monitor NIF. In this work, an innovative molecularly imprinted polymer dual-emission fluorescent sensor (CDs@PDA-MIPs) strategy was successfully designed for sensitive detection of NIF. The fluorescent intensity of the probe decreased with increasing NIF concentration, showing a satisfactory linear relationship within the range 1.0 × 10-6 M ~ 5.0 × 10-3 M. The LOD of NIF was 9.38 × 10-7 M (S/N = 3) in fluorescence detection. The application of the CDs@PDA-MIPs in actual samples such as urine and Qiangli Dingxuan tablets has been verified, with recovery ranging from 97.8 to 102.8% for NIF. Therefore, the fluorescent probe demonstrates great potential as a sensing system for detecting NIF.


Assuntos
Carbono , Dopamina , Corantes Fluorescentes , Limite de Detecção , Polímeros Molecularmente Impressos , Nifedipino , Pontos Quânticos , Espectrometria de Fluorescência , Pontos Quânticos/química , Nifedipino/química , Nifedipino/análise , Corantes Fluorescentes/química , Polímeros Molecularmente Impressos/química , Dopamina/urina , Dopamina/análise , Carbono/química , Espectrometria de Fluorescência/métodos , Humanos , Polimerização , Impressão Molecular , Comprimidos/análise
2.
Molecules ; 29(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38731427

RESUMO

Dopamine (DA) and uric acid (UA) are essential for many physiological processes in the human body. Abnormal levels of DA and UA can lead to multiple diseases, such as Parkinson's disease and gout. In this work, a three-dimensional reduced graphene oxide-MXene (3D rGO-Ti3C2) composite electrode was prepared using a simple one-step hydrothermal reduction process, which could separate the oxidation potentials of DA and UA, enabling the simultaneous detection of DA and UA. The 3D rGO-Ti3C2 electrode exhibited excellent electrocatalytic activity towards both DA and UA. In 0.01 M PBS solution, the linear range of DA was 0.5-500 µM with a sensitivity of 0.74 µA·µM-1·cm-2 and a detection limit of 0.056 µM (S/N = 3), while the linear range of UA was 0.5-60 µM and 80-450 µM, with sensitivity of 2.96 and 0.81 µA·µM-1·cm-2, respectively, and a detection limit of 0.086 µM (S/N = 3). In 10% fetal bovine serum (FBS) solution, the linear range of DA was 0.5-500 µM with a sensitivity of 0.41 µA·µM-1·cm-2 and a detection limit of 0.091 µM (S/N = 3). The linear range of UA was 2-500 µM with a sensitivity of 0.11 µA·µM-1·cm-2 and a detection limit of 0.6 µM (S/N = 3). The modified electrode exhibited advantages such as high sensitivity, a strong anti-interference capability, and good repeatability. Furthermore, the modified electrode was successfully used for DA measurement in vivo. This could present a simple reliable route for neurotransmitter detection in neuroscience.


Assuntos
Dopamina , Técnicas Eletroquímicas , Eletrodos , Grafite , Ácido Úrico , Grafite/química , Ácido Úrico/análise , Ácido Úrico/sangue , Dopamina/análise , Dopamina/sangue , Técnicas Eletroquímicas/métodos , Limite de Detecção , Oxirredução , Humanos , Titânio/química , Animais
3.
Sensors (Basel) ; 24(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38732893

RESUMO

An abnormal level of dopamine (DA), a kind of neurotransmitter, correlates with a series of diseases, including Parkinson's disease, Willis-Ekbom disease, attention deficit hyperactivity disorder, and schizophrenia. Hence, it is imperative to achieve a precise, rapid detection method in clinical medicine. In this study, we synthesized nanocomposite carbon aerogels (CAs) doped with iron and iron carbide, based on algae residue-derived biomass materials, using Fe(NO3)3 as the iron source. The modified glassy carbon electrode (GCE) for DA detection, denoted as CAs-Fe/GCE, was prepared through surface modification with this composite material. X-ray photoelectron spectroscopy and X-ray diffraction characterization confirmed the successful doping of iron into the as-prepared CAs. Additionally, the electrochemical behavior of DA on the modified electrode surface was investigated and the results demonstrate that the addition of the CAs-Fe promoted the electron transfer rate, thereby enhancing their sensing performance. The fabricated electrochemical DA biosensor exhibits an accurate detection of DA in the concentration within the range of 0.01~200 µM, with a detection limit of 0.0033 µM. Furthermore, the proposed biosensor is validated in real samples, showing its high applicability for the detection of DA in beverages.


Assuntos
Técnicas Biossensoriais , Carbono , Dopamina , Técnicas Eletroquímicas , Eletrodos , Ferro , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Dopamina/análise , Dopamina/química , Carbono/química , Ferro/química , Técnicas Eletroquímicas/métodos , Géis/química , Limite de Detecção , Espectroscopia Fotoeletrônica , Nanocompostos/química
4.
Sensors (Basel) ; 24(9)2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733043

RESUMO

In this paper, a novel aptamer-modified nitrogen-doped graphene microelectrode (Apt-Au-N-RGOF) was fabricated and used to specifically identify and detect dopamine (DA). During the synthetic process, gold nanoparticles were loaded onto the active sites of nitrogen-doped graphene fibers. Then, aptamers were modified on the microelectrode depending on Au-S bonds to prepare Apt-Au-N-RGOF. The prepared microelectrode can specifically identify DA, avoiding interference with other molecules and improving its selectivity. Compared with the N-RGOF microelectrode, the Apt-Au-N-RGOF microelectrode exhibited higher sensitivity, a lower detection limit (0.5 µM), and a wider linear range (1~100 µM) and could be applied in electrochemical analysis fields.


Assuntos
Aptâmeros de Nucleotídeos , Dopamina , Técnicas Eletroquímicas , Ouro , Grafite , Nanopartículas Metálicas , Microeletrodos , Grafite/química , Dopamina/análise , Dopamina/química , Aptâmeros de Nucleotídeos/química , Ouro/química , Técnicas Eletroquímicas/métodos , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Nitrogênio/química
5.
Luminescence ; 39(5): e4760, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38738510

RESUMO

The present communication reports on the synthesis of a novel methyl-pyridone azo fluorescent tag (MPAFT) were proven through 1H (NMR), FT-IR, UV-vis, and high-resolution mass spectrometry. The quantum chemical parameters of MPAFT were evaluated using density functional theory (DFT) analysis. It was further investigated for its latent fingerprint (LFPs) in various surfaces and anticounterfeiting applications. By exposing Level I-Level III, ridge features to UV light with a wavelength of 365 nm, a bioimaging investigation has also demonstrated the potential of MPAFT's emission behaviour. The cyclic voltammetry (CV) and linear sweep voltammetry (LSV) at MPAFT/MGCE (modified glassy carbon electrode) were used to explore the electrochemical sensitivity and reliable detection of dopamine (DA) in neutral PBS (pH 7) electrolyte solution, and the results show good sensitivity and detection. The lower detection limit for LSV was 0.81 µM under optimum conditions.


Assuntos
Dopamina , Técnicas Eletroquímicas , Corantes Fluorescentes , Pirazóis , Piridonas , Piridonas/química , Dopamina/análise , Dopamina/química , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Pirazóis/química , Humanos , Estrutura Molecular , Teoria da Densidade Funcional , Imagem Óptica , Processos Fotoquímicos
6.
Langmuir ; 40(20): 10718-10725, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38728259

RESUMO

For accurate in vivo detection, nonspecific adsorption of biomacromolecules such as proteins and cells is a severe issue. The adsorption leads to electrode passivation, significantly compromising both the sensitivity and precision of sensing. Meanwhile, common antibiofouling modifications, such as polymer coatings, still grapple with issues related to biocompatibility, electrode passivation, and miniaturization. Herein, we propose a composite antibiofouling coating strategy based on zwitterionic metal-organic frameworks (Z-MOFs) and a combination of acrylamide hydrogels. On a well-designed TiO2/Z-MOF/hydrogel photoelectrode, we achieve highly sensitive and selective detection of dopamine in complex biological environments. The hydrogel's three-dimensional porous structure combined with unique microporous architecture of Z-MOF ensures effective sieving of interfering macromolecules while preserving efficient small molecules and electron transport. This innovative approach paves the way for constructing miniature, in vivo antibiofouling sensors for molecule monitoring in living organisms with complicated chemical environments.


Assuntos
Técnicas Biossensoriais , Dopamina , Hidrogéis , Titânio , Hidrogéis/química , Dopamina/análise , Dopamina/química , Técnicas Biossensoriais/métodos , Titânio/química , Incrustação Biológica/prevenção & controle , Técnicas Eletroquímicas/métodos , Processos Fotoquímicos , Estruturas Metalorgânicas/química , Materiais Biocompatíveis/química , Eletrodos
7.
Biosens Bioelectron ; 256: 116277, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38613934

RESUMO

The field of biosensing would significantly benefit from a disruptive technology enabling flexible manufacturing of uniform electrodes. Inkjet printing holds promise for this, although realizing full electrode manufacturing with this technology remains challenging. We introduce a nitrogen-doped carboxylated graphene ink (NGA-ink) compatible with commercially available printing technologies. The water-based and additive-free NGA-ink was utilized to produce fully inkjet-printed electrodes (IPEs), which demonstrated successful electrochemical detection of the important neurotransmitter dopamine. The cost-effectiveness of NGA-ink combined with a total cost per electrode of $0.10 renders it a practical solution for customized electrode manufacturing. Furthermore, the high carboxyl group content of NGA-ink (13 wt%) presents opportunities for biomolecule immobilization, paving the way for the development of advanced state-of-the-art biosensors. This study highlights the potential of NGA inkjet-printed electrodes in revolutionizing sensor technology, offering an affordable, scalable alternative to conventional electrochemical systems.


Assuntos
Técnicas Biossensoriais , Dopamina , Técnicas Eletroquímicas , Grafite , Tinta , Impressão , Técnicas Biossensoriais/instrumentação , Grafite/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Dopamina/análise , Eletrodos , Desenho de Equipamento , Nitrogênio/química , Humanos
8.
Mikrochim Acta ; 191(5): 280, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649540

RESUMO

An interfacial galvanic replacement strategy to controllable synthesize palladium nanoparticles (Pd NPs)-modified NiFe MOF nanocomposite on nickel foam, which served as an efficient sensing platform for quantitative determination of dopamine (DA). Pd NPs grown in situ on the nanosheets of NiFe MOF via self-driven galvanic replacement reaction (GRR) and well uniform distribution was achieved. This method effectively reduced the aggregation of metallic nanoparticles and significantly promoted the electron transfer rate during the electrochemical process, leading to improved electrocatalytic activity for DA oxidation. Remarkably, the precisely constructed biosensor achieved a low detection limit (LOD) of 0.068 µM and recovery of 94.1% (RSD 6.7%, N = 3) for simulated real sample detection and also exhibited superior selectivity and stability. The results confirmed that the as-fabricated Pd-NiFe/NF composite electrode could realize the quantitative determination of DA and showed promising prospects in real sample biosensing.


Assuntos
Técnicas Biossensoriais , Dopamina , Estruturas Metalorgânicas , Nanoestruturas , Dopamina/análise , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/normas , Níquel/química , Eletrodos/normas , Paládio/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Microscopia Eletrônica de Varredura , Estruturas Metalorgânicas/síntese química , Estruturas Metalorgânicas/ultraestrutura , Sensibilidade e Especificidade , Condutividade Elétrica , Microscopia Eletrônica de Transmissão , Ferro/química , Reprodutibilidade dos Testes
9.
J Mater Chem B ; 12(19): 4724-4735, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38655674

RESUMO

We have developed a highly sensitive and reliable fluorescence resonance energy transfer (FRET) probe using nitro-dopamine (ND) and dopamine (DA) coated MnO2 nanosheet (ND@MnO2 NS and DA@MnO2 NS) as an energy acceptor and MoS2 quantum dots (QDs) as an energy donor. By employing surface-modified MnO2 NS, we can effectively reduce the fluorescence intensity of MoS2 QDs through FRET. It can reduce MnO2 NS to Mn2+ and facilitate the fluorescence recovery of the MoS2 QDs. This ND@MnO2 NS@MoS2 QD-based nanoprobe demonstrates excellent sensitivity to GSH, achieving an LOD of 22.7 nM in an aqueous medium while exhibiting minimal cytotoxicity and good biocompatibility. Moreover, our sensing platform shows high selectivity to GSH towards various common biomolecules and electrolytes. Confocal fluorescence imaging revealed that the nanoprobe can image GSH in A549 cells. Interestingly, the ND@MnO2 NS nanoprobe demonstrates no cytotoxicity in living cancer cells, even at concentrations up to 100 µg mL-1. Moreover, the easy fabrication and eco-friendliness of ND@MnO2 NS make it a rapid and simple method for detecting GSH. We envision the developed nanoprobe as an incredible platform for real-time monitoring of GSH levels in both extracellular and intracellular mediums, proving valuable for biomedical research and clinical diagnostics.


Assuntos
Dissulfetos , Dopamina , Glutationa , Compostos de Manganês , Molibdênio , Nanocompostos , Óxidos , Pontos Quânticos , Humanos , Compostos de Manganês/química , Dissulfetos/química , Óxidos/química , Pontos Quânticos/química , Molibdênio/química , Glutationa/análise , Glutationa/química , Dopamina/análise , Nanocompostos/química , Transferência Ressonante de Energia de Fluorescência , Células A549 , Tamanho da Partícula , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química
10.
ACS Appl Bio Mater ; 7(5): 3143-3153, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38662615

RESUMO

Novel and flexible disposable laser-induced graphene (LIG) sensors modified with graphene conductive inks have been developed for dopamine and interleukin-6 (IL-6) detection. The LIG sensors exhibit high reproducibility (relative standard deviation, RSD = 0.76%, N = 5) and stability (RSD = 4.39%, N = 15) after multiple bendings, making the sensors ideal for wearable and stretchable bioelectronics applications. We have developed electrode coatings based on graphene conductive inks, poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (G-PEDOT:PSS) and polyaniline (G-PANI), for working electrode modification to improve the sensitivity and limit of detection (LOD). The selectivity of LIG sensors modified with the G-PANI ink is 41.47 times higher than that of the screen-printed electrode with the G-PANI ink modification. We have compared our fabricated bare laser-engraved Kapton sensor (LIG) with the LIG sensors modified with G-PEDOT (LIG/G-PEDOT) and G-PANI (LIG/G-PANI) conductive inks. We have further compared the performance of the fabricated electrodes with commercially available screen-printed electrodes (SPEs) and screen-printed electrodes modified with G-PEDOT:PSS (SPE/G-PEDOT:PSS) and G-PANI (SPE/G-PANI). SPE/G-PANI has a lower LOD of 0.632 µM compared to SPE/G-PEDOT:PSS (0.867 µM) and SPE/G-PANI (1.974 µM). The lowest LOD of the LIG/G-PANI sensor (0.4084 µM, S/N = 3) suggests that it can be a great alternative to measure dopamine levels in a physiological medium. Additionally, the LIG/G-PANI electrode has excellent LOD (2.6234 pg/mL) to detect IL-6. Also, the sensor is successfully able to detect ascorbic acid (AA), dopamine (DA), and uric acid (UA) in their ternary mixture. The differential pulse voltammetry (DPV) result shows peak potential separation of 229, 294, and 523 mV for AA-DA, DA-UA, and UA-AA, respectively.


Assuntos
Dopamina , Eletrodos , Grafite , Tinta , Lasers , Teste de Materiais , Nanocompostos , Grafite/química , Dopamina/análise , Nanocompostos/química , Humanos , Interleucina-6/análise , Técnicas Biossensoriais/instrumentação , Tamanho da Partícula , Imunoensaio/instrumentação , Técnicas Eletroquímicas/instrumentação , Materiais Biocompatíveis/química
11.
ACS Nano ; 18(15): 10596-10608, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38557034

RESUMO

Continuously monitoring neurotransmitter dynamics can offer profound insights into neural mechanisms and the etiology of neurological diseases. Here, we present a miniaturized implantable fluorescence probe integrated with metal-organic frameworks (MOFs) for deep brain dopamine sensing. The probe is assembled from physically thinned light-emitting diodes (LEDs) and phototransistors, along with functional surface coatings, resulting in a total thickness of 120 µm. A fluorescent MOF that specifically binds dopamine is introduced, enabling a highly sensitive dopamine measurement with a detection limit of 79.9 nM. A compact wireless circuit weighing only 0.85 g is also developed and interfaced with the probe, which was later applied to continuously monitor real-time dopamine levels during deep brain stimulation in rats, providing critical information on neurotransmitter dynamics. Cytotoxicity tests and immunofluorescence analysis further suggest a favorable biocompatibility of the probe for implantable applications. This work presents fundamental principles and techniques for integrating fluorescent MOFs and flexible electronics for brain-computer interfaces and may provide more customized platforms for applications in neuroscience, disease tracing, and smart diagnostics.


Assuntos
Dopamina , Estruturas Metalorgânicas , Ratos , Animais , Dopamina/análise , Estruturas Metalorgânicas/metabolismo , Corantes Fluorescentes/metabolismo , Fluorescência , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Neurotransmissores/metabolismo
12.
J Chromatogr A ; 1724: 464910, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38657316

RESUMO

A simplified approach for preparation of sandwich type molecularly imprinted polymers (PPDA-MIPs) is proposed for simultaneously identify Low-density lipoprotein (LDL) and dispose "bad cholesterol". Porous polydopamine nanosphere (PPDA) is applied as a matrix for immobilization of LDL, and the imprinted layer is formed by dopamine acting as a functional monomer. Since imprinted cavities exhibit shape memory effects in terms of recognizing selectivity, the PPDA-MIPs exhibit excellent selectivity toward LDL and a substantial binding capacity of 550.3 µg mg-1. Meanwhile, six adsorption/desorption cycles later, the adsorption efficiency of 83.09 % is still achieved, indicating the adequate stability and reusability of PPDA-MIPs. Additionally, over 80 % of cholesterol is recovered, indicating the completeness of "bad cholesterol" removal in LDL. Lastly, as demonstrated by gel electrophoresis, PPDA-MIPs performed satisfactory behavior for the removal of LDL from the goat serum sample.


Assuntos
Colesterol , Indóis , Lipoproteínas LDL , Polímeros Molecularmente Impressos , Polímeros , Lipoproteínas LDL/sangue , Lipoproteínas LDL/química , Lipoproteínas LDL/isolamento & purificação , Adsorção , Polímeros/química , Colesterol/sangue , Colesterol/química , Indóis/química , Animais , Polímeros Molecularmente Impressos/química , Dopamina/sangue , Dopamina/química , Dopamina/isolamento & purificação , Dopamina/análise , Impressão Molecular/métodos , Cabras , Nanosferas/química
13.
Talanta ; 274: 126003, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38569374

RESUMO

Antibiotics in aquatic environments raise health concerns. Therefore, the rapid, on-site, and accurate detection of antibiotic residues is crucial for protecting the environment and human health. Herein, a dumbbell-shaped iron (Fe3+)-dopamine coordination nanozyme (Fe-DCzyme) was developed via an iron-driven self-assembly strategy. It exhibited excellent peroxidase-like activity, which can be quenched by adding l-cysteine to prevent Fe3+/Fe2+ electron transfer but restored by adding norfloxacin. Given the 'On-Off-On' effect of peroxidase-like activity, Fe-DCzyme was used as a colourimetric sensor for norfloxacin detection, and showed a wide linear range from 0.05 to 6.00 µM (R2 = 0.9950) and LOD of 27.0 nM. A portable smartphone-assisted detection platform using Fe-DCzyme was also designed to convert norfloxacin-induced color changes into RGB values as well as to realise the rapid, on-site and quantitative detection of norfloxacin. A good linear relation (0.10-6.00 µM) and high sensitivity (LOD = 79.3 nM) were achieved for the smartphone-assisted Fe-DCzyme detection platform. Its application was verified using norfloxacin spiking methods with satisfactory recoveries (92.66%-119.65%). Therefore, the portable smartphone-assisted Fe-DCzyme detection platform with low cost and easy operation can be used for the rapid, on-site and visual quantitative detection of antibiotic residues in water samples.


Assuntos
Colorimetria , Dopamina , Ferro , Norfloxacino , Smartphone , Norfloxacino/análise , Norfloxacino/química , Ferro/química , Dopamina/análise , Dopamina/química , Colorimetria/métodos , Antibacterianos/análise , Antibacterianos/química , Poluentes Químicos da Água/análise , Limite de Detecção , Nanoestruturas/química
14.
Biosens Bioelectron ; 257: 116332, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38677016

RESUMO

In situ detection of dopamine (DA) at single-cell level is critical for exploring neurotransmitter-related biological processes and diseases. However, the low content of DA and a variety of distractors with similar oxidation potentials as DA in cells brought great challenges. Here, a sensitive and specific electrochemical nanosensor was proposed for in situ detection of DA in single living cells based on nanodiamond (ND) and molecularly imprinted polymer (MIP)-functionalized carbon fiber nanoelectrode (ND/MIP/CFNE). Due to its excellent electrocatalytic property, ND was modified to the surface of CFNE based on amide bonding. Compared with bare CFNE, ND-modified CFNE can enhance oxidation currents of DA by about 4-fold, improving signal-to-noise ratio and detection sensitivity. MIP was further electropolymerized on the surface of nanoelectrodes to achieve specific capture and recognition of DA, which could avoid the interference of complex matrix and analogs in cells. Taking advantage of the precise positioning capability of a single-cell analyzer and micromanipulator, ND/MIP/CFNE could be precisely inserted into different locations of single cells and monitor oxidation signal of DA. The concentration of DA in the cytoplasm of single pheochromocytoma (PC12) cell was measured to be about 0.4 µM, providing a sensitive and powerful method for single-cell detection. Furthermore, the nanoelectrodes can monitor the fluctuation of intracellular DA under drug stimulation, providing new ideas and methods for new drug development and efficacy evaluation.


Assuntos
Técnicas Biossensoriais , Dopamina , Técnicas Eletroquímicas , Polímeros Molecularmente Impressos , Análise de Célula Única , Dopamina/análise , Dopamina/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Células PC12 , Técnicas Eletroquímicas/métodos , Polímeros Molecularmente Impressos/química , Animais , Ratos , Nanodiamantes/química , Eletrodos , Fibra de Carbono/química , Impressão Molecular/métodos , Limite de Detecção , Polímeros/química
15.
Biosens Bioelectron ; 256: 116242, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631133

RESUMO

Psychiatric disorders are associated with serve disturbances in cognition, emotional control, and/or behavior regulation, yet few routine clinical tools are available for the real-time evaluation and early-stage diagnosis of mental health. Abnormal levels of relevant biomarkers may imply biological, neurological, and developmental dysfunctions of psychiatric patients. Exploring biosensors that can provide rapid, in-situ, and real-time monitoring of psychiatric biomarkers is therefore vital for prevention, diagnosis, treatment, and prognosis of mental disorders. Recently, psychiatric biosensors with high sensitivity, selectivity, and reproducibility have been widely developed, which are mainly based on electrochemical and optical sensing technologies. This review presented psychiatric disorders with high morbidity, disability, and mortality, followed by describing pathophysiology in a biomarker-implying manner. The latest biosensors developed for the detection of representative psychiatric biomarkers (e.g., cortisol, dopamine, and serotonin) were comprehensively summarized and compared in their sensitivities, sensing technologies, applicable biological platforms, and integrative readouts. These well-developed biosensors are promising for facilitating the clinical utility and commercialization of point-of-care diagnostics. It is anticipated that mental healthcare could be gradually improved in multiple perspectives, ranging from innovations in psychiatric biosensors in terms of biometric elements, transducing principles, and flexible readouts, to the construction of 'Big-Data' networks utilized for sharing intractable psychiatric indicators and cases.


Assuntos
Biomarcadores , Técnicas Biossensoriais , Transtornos Mentais , Humanos , Biomarcadores/análise , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Dopamina/análise , Técnicas Eletroquímicas/métodos , Transtornos Mentais/diagnóstico , Transtornos Mentais/fisiopatologia , Saúde Mental , Serotonina/análise , Serotonina/sangue , Serotonina/metabolismo
16.
Mikrochim Acta ; 191(4): 197, 2024 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-38483622

RESUMO

A fully reusable electrochemical device is proposed for the first time made from laser cutting and a homemade conductive ink composed of carbon and nail polish. As a sensor substrate, we applied polymethyl methacrylate, which allows the surface to be renewed by simply removing and reapplying a new layer of ink. In addition to the ease of renewing the sensor's conductive surface, the design of the device has allowed for the integration of different forms of analysis. The determination of L-Dopa was performed using DPV, which presented a linear response range between 5.0 and 1000.0 µmol L-1, and a LOD of 0.11 µmol L-1. For dopamine, a flow injection analysis system was employed, and using the amperometric technique measurements were performed with a linear ranging from 2.0 to 100.0 µmol L-1 and a LOD of 0.26 µmol L-1. To demonstrate its applicability, the device was used in the quantification of analytes in pharmaceutical drug and synthetic urine samples.


Assuntos
Grafite , Levodopa , Levodopa/análise , Dopamina/análise , Técnicas Eletroquímicas/métodos , Eletrodos , Reprodutibilidade dos Testes
17.
Dalton Trans ; 53(14): 6275-6281, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38506644

RESUMO

The detection of ascorbic acid (AA), dopamine (DA), and uric acid (UA) is not only of great significance in the areas of biomedicine and neurochemistry but also helpful in disease diagnosis and pathology research. Due to their diverse structures, designability, and large specific surface areas, metal-organic frameworks (MOFs) have recently caught considerable attention in the electrochemical field. Herein, a family of heterometallic MOFs with amino modification, MIL-125(Ti-Al)-xNH2 (x = 0%, 25%, 50%, 75%, and 100%), were synthesized and employed as electrochemical sensors for the detection of AA, DA, and UA. Among them, MIL-125(Ti-Al)-75%NH2 exhibited the most promising electrochemical behavior with 40% doping of carbon black in 0.1 M PBS (pH = 7.10), which displayed individual detection performance with wide linear detection ranges (1.0-6.5 mM for AA, 5-100 µM for DA and 5-120 µM for UA) and low limits of detection (0.215 mM for AA, 0.086 µM for DA, and 0.876 µM for UA, S/N = 3). Furthermore, the as-prepared MIL-125(Ti-Al)-75%NH2/GCE provided a promising platform for future application in real sample analysis, owing to its excellent anti-interference performance and good stability.


Assuntos
Dopamina , Estruturas Metalorgânicas , Dopamina/análise , Ácido Úrico/análise , Ácido Ascórbico/química , Eletrodos , Titânio , Técnicas Eletroquímicas
18.
Talanta ; 274: 125940, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38537354

RESUMO

Dopamine, the main catecholamine neurotransmitter plays an important role in renal, cardiovascular, central nervous systems, and pathophysiological processes. The abnormal dopamine levels can result in neurological disorders such as Parkinson's, Alzheimer's, schizophrenia, acute anxiety, neuroblastoma and also contribute to cognitive dysfunctions. Given the widespread importance of dopamine concentration levels, it is imperative to develop sensors that are able to monitor dopamine. Herein, we have developed pre-anodized disposable paper electrode modified with 1-pyrenebutyric acid, for the selective and sensitive determination of dopamine. The sensor was characterized with Fourier transform infrared spectroscopy, Energy dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and electrochemical techniques for addressing the robust formation and electrochemical activity. The modified electrode exhibited excellent electrocatalytic activity towards dopamine without the common interference from ascorbic acid. The calibration plot for the dopamine sensor resulted linear range from 0.003 µM to 0.5 µM with a detection limit of 0.11 nM. The sensor's potential utility was tested by monitoring dopamine concentration changes in rat brain homogenates when subjected to neurotoxicity. The developed sensor was validated with gold-standard UV-Vis spectroscopy studies and computational studies were performed to understand the interaction between 1-pyrenebutyric acid and dopamine.


Assuntos
Encéfalo , Dopamina , Eletrodos , Animais , Dopamina/análise , Dopamina/metabolismo , Ratos , Encéfalo/metabolismo , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Pirenos/química , Limite de Detecção
19.
Analyst ; 149(9): 2728-2737, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38525963

RESUMO

This work presents the synthesis and characterization of an innovative F,S-doped carbon dots/CuONPs hybrid nanostructure obtained by a direct mixture between F,S-doped carbon dots obtained electrochemically and copper nitrate alcoholic solution. The hybrid nanostructures synthesized were characterized by absorption spectroscopy in the Ultraviolet region (UV-vis), high-resolution transmission electron microscopy (HRTEM), X-ray photoelectron spectroscopy (XPS), and different electrochemical techniques. The fluoride and sulfur-doped carbon dots/CuONPs nanostructures were used to prepare a non-enzymatic biosensor on a printed carbon electrode, exhibiting excellent electrocatalytic activity for the simultaneous determination of NADH, dopamine, and uric acid in the presence of ascorbic acid with a detection limit of 20, 80, and 400 nmol L-1, respectively. The non-enzymatic biosensors were also used to determine NADH, dopamine, and uric acid in plasma, and they did not suffer significant interference from each other.


Assuntos
Técnicas Biossensoriais , Carbono , Cobre , Dopamina , Técnicas Eletroquímicas , Limite de Detecção , NAD , Ácido Úrico , Ácido Úrico/sangue , Ácido Úrico/química , Técnicas Biossensoriais/métodos , Dopamina/sangue , Dopamina/análise , Carbono/química , NAD/química , NAD/sangue , Cobre/química , Técnicas Eletroquímicas/métodos , Humanos , Enxofre/química , Fluoretos/química , Pontos Quânticos/química , Nanoestruturas/química , Eletrodos
20.
Anal Chim Acta ; 1299: 342441, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38499429

RESUMO

BACKGROUND: In health assessment and personalized medical services, accurate detection of biological markers such as dopamine (DA) and uric acid (UA) in sweat is crucial for providing valuable physiological information. However, there are challenges in detecting sweat biomarkers due to their low concentrations, variations in sweat yield among individuals, and the need for efficient sweat collection. RESULTS: We synthesized CuNi-MOF@rGO as a high-activity electrocatalyst and investigated its feasibility and electrochemical mechanism for simultaneously detecting low-concentration biomarkers UA and DA. Interaction between the non-coordinating carboxylate group and the sample produces effective separation signals for DA and UA. The wearable biomimetic biosensor has a wide linear range of 1-500 µM, with a detection limit of 9.41 µM and sensitivity of 0.019 µA µM-1 cm-2 for DA, and 10-1000 µM, with a detection limit of 9.09 µM and sensitivity of 0.026 µA µM-1 cm-2 for UA. Thus, our sensor performs excellently in detecting low-concentration biomarkers. To improve sweat collection, we designed a microfluidic-controlled device with hydrophilic modification in the microchannel. Experimental results show optimal ink flow at 2% concentration. Overall, we developed an innovative and highly active electrocatalyst, successfully enabling simultaneous detection of low-concentration biomarkers UA and DA. SIGNIFICANCE: This study provides a strategy for sweat analysis and health monitoring. Moreover, the sensor also showed good performance in detecting real sweat samples. This study has shown great potential in future advances in sweat analysis and health monitoring.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Humanos , Suor/química , Dopamina/análise , Ácido Úrico/análise , Técnicas Biossensoriais/métodos , Biomarcadores , Técnicas Eletroquímicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA