1.
ACS Biomater Sci Eng ; 10(5): 3057-3068, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38641433

RESUMO

Blood-contacting catheters play a pivotal role in contemporary medical treatments, particularly in the management of cardiovascular diseases. However, these catheters exhibit inappropriate wettability and lack antimicrobial characteristics, which often lead to catheter-related infections and thrombosis. Therefore, there is an urgent need for blood contact catheters with antimicrobial and anticoagulant properties. In this study, we employed tannic acid (TA) and 3-aminopropyltriethoxysilane (APTES) to create a stable hydrophilic coating under mild conditions. Heparin (Hep) and poly(lysine) (PL) were then modified on the TA-APTES coating surface using the layer-by-layer (LBL) technique to create a superhydrophilic TA/APTES/(LBL)4 coating on silicone rubber (SR) catheters. Leveraging the superhydrophilic nature of this coating, it can be effectively applied to blood-contacting catheters to impart antibacterial, antiprotein adsorption, and anticoagulant properties. Due to Hep's anticoagulant attributes, the activated partial thromboplastin time and thrombin time tests conducted on SR/TA-APTES/(LBL)4 catheters revealed remarkable extensions of 276 and 103%, respectively, when compared to uncoated commercial SR catheters. Furthermore, the synergistic interaction between PL and TA serves to enhance the resistance of SR/TA-APTES/(LBL)4 catheters against bacterial adherence, reducing it by up to 99.9% compared to uncoated commercial SR catheters. Remarkably, the SR/TA-APTES/(LBL)4 catheter exhibits good biocompatibility with human umbilical vein endothelial cells in culture, positioning it as a promising solution to address the current challenges associated with blood-contact catheters.


Assuntos
Catéteres , Materiais Revestidos Biocompatíveis , Heparina , Polifenóis , Taninos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Humanos , Catéteres/microbiologia , Polifenóis/química , Polifenóis/farmacologia , Heparina/química , Heparina/farmacologia , Taninos/química , Taninos/farmacologia , Silanos/química , Silanos/farmacologia , Anticoagulantes/química , Anticoagulantes/farmacologia , Propilaminas/química , Aminas/química , Aminas/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Polilisina/química , Polilisina/farmacologia , Propriedades de Superfície , Interações Hidrofóbicas e Hidrofílicas , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Elastômeros de Silicone/química , Adsorção , Escherichia coli/efeitos dos fármacos
2.
J Prosthet Dent ; 131(5): 980.e1-980.e8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38448355

RESUMO

STATEMENT OF PROBLEM: The choice of cleaning method is an important consideration for lengthening the serviceable time of facial prostheses as microbial organisms and biofilms could degrade facial prostheses and cause skin irritation. Whether microwave disinfection is a suitable cleaning method without degradation of the properties of a prosthesis is unclear. PURPOSE: The purpose of this in vitro study was to measure the color stability of 6 commonly used facial silicone elastomers after microwave disinfection over a simulated 1.5-year period. MATERIAL AND METHODS: Six different facial silicone elastomers: MDX4-4210, MDX4-4210/Type A, M511, A-2186, VST-50, and A-2000 were mixed with intrinsic silicone white opacifier (except for the control group) and subsequently combined with 4 silicone intrinsic pigment color groups: red (R), yellow (Y), burnt sienna (B), and a mixture of R+Y+B (M). The control group was a silicone elastomer without opacifier or pigment. Each of the 30 experimental groups consisted of 5 specimens (N=150). Five specimens were placed in a 250-mL Erlenmeyer flask filled with 160 mL of tap water. Seven flasks were then placed in a 660-W microwave oven. An exposure of 6 minutes was used according to the antimicrobial efficacy of microwave disinfection protocol on facial silicone prostheses with a final water temperature of 60 °C for 18 times (simulating 1.5 years of microwave disinfection with one 6-minute exposure monthly). A spectrophotometer was used to measure reflectance color change values (∆E). Color differences were calculated following CIELab (∆E*ab) and CIEDE2000 (∆E00) formulae. ∆E*ab and ∆E00 were statistically analyzed by a linear mixed effects model with 3 factors (silicone type, color shade, and time) using the R Statistical software program (α=.05). RESULTS: Both ∆E*ab and ∆E00 of all silicone elastomers studied were less than the visual perceptibility thresholds (∆E*ab<1.1 and E00<0.7) and were considered clinically acceptable (∆E*ab<3.0 and E00<2.1) after the 1.5-year simulation of microwave disinfection. Yellow and blue pigments had more effect on MDX4-4210 and M511, while red pigment had more effect on MDX4-4210, MDX4-4210/Type A, and M511 (P<.05). Nevertheless, the values were still below the perceptibility threshold (∆E*ab≤1.0 and E00<0.6). CONCLUSIONS: All 6 facial silicone elastomers maintained clinically acceptable color after 18 months of exposure to microwave disinfection.


Assuntos
Cor , Desinfecção , Prótese Maxilofacial , Micro-Ondas , Elastômeros de Silicone , Micro-Ondas/uso terapêutico , Desinfecção/métodos , Elastômeros de Silicone/química , Pigmentação em Prótese , Humanos , Técnicas In Vitro , Teste de Materiais , Dimetilpolisiloxanos
3.
J Microorg Control ; 29(1): 39-44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38508761

RESUMO

During the disinfection of indoor spaces using gaseous hypochlorous acid (HOCl(g)), inhalation is the most common route of exposure for humans. In this study, an artificial human respiratory tract model was exposed to 12-140 ppb HOCl(g) at an aspiration flow rate of 800 mL/s for 15 h in a 1 m3 chamber. The respiratory tract model was equipped with 5th order bronchi and all gas-contact parts were made of silicone rubber with no other chlorine-consuming substances. The concentration of HOCl(g) reaching the lung pseudo-space was approximately 47.4% of the HOCl(g) concentrations in the chamber and was calculated to be very close to zero when the chamber concentration was less than 20.5 ppb. The disappearance of HOCl(g) during inhalation is likely due to the adsorption of HOCl(g) on the gas-contact silicone rubber surfaces. The cytotoxicity of HOCl(g) on respiratory epithelial cells was also examined using human air-liquid-interface airway tissue models. Human nasal epithelium and bronchiolar epithelium were exposed to 100 ppb and 500 ppb HOCl(g) for 8 h and 5 d, respectively. No significant effects of HOCl(g) on cell viability and ciliary activity were observed in any cell type, indicating that low concentrations of HOCl(g), less than 500 ppb, had no cytotoxic effect.


Assuntos
Gases , Ácido Hipocloroso , Humanos , Ácido Hipocloroso/farmacologia , Elastômeros de Silicone , Células Epiteliais , Pulmão
4.
J Oral Sci ; 66(2): 116-119, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38447982

RESUMO

PURPOSE: This study investigated the color stability of different commercially available silicone materials for facial prostheses upon exposure to everyday beverages. It was hypothesized that the beverages would not alter the color of the silicone under conditions simulating daily exposure. METHODS: Sixty specimens were fabricated using two materials - VST-50 and Silfy - and exposed to commercially available cold mineral water, tea, or coffee. Specimen color was evaluated on days 1 and 15. The color was measured with a spectrophotometer based on CIELab system and color differences were calculated as ΔE. Statistical analysis was performed using the Kruskal-Wallis test and Mann-Whitney U test. RESULTS: The mean ΔE values after 15 days of exposure to mineral water, cold green tea, and coffee were 1.016, 3.480, and 3.636 for VST-50 and 0.440, 0.798, and 1.425 for Silfy, respectively. Both materials showed significant differences in color, and VST-50 showed a greater color change than Silfy, especially for coffee. CONCLUSION: Pigmented silicone elastomers have low color stability, leading to an overall color change in silicone prostheses when exposed to pigmented beverages. Color changes in such prostheses can be mitigated by selecting materials with better color stability to extend their longevity.


Assuntos
Prótese Maxilofacial , Águas Minerais , Elastômeros de Silicone , Cor , Café , Pigmentação em Prótese , Teste de Materiais , Bebidas
5.
J Long Term Eff Med Implants ; 34(3): 43-53, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38505893

RESUMO

The aim of this systematic review was to identify and analyze the findings of various studies that analyzed the changes in the color stability of maxillofacial prosthetic materials after the addition of various colorants and nanoparticles and assess the change in color after being subjected to either natural or artificial accelerated aging as well as outdoor aging. This systematic review was conducted in accordance with the guidelines of transparent reporting of systematic reviews and meta-analysis (PRISMA Statement). The primary objective of this systematic review was to evaluate the color stability of maxillofacial prosthesis. The secondary objective was to assess the effect of various colorants; pigments; opacifiers; UV absorbers-such as inorganic colorants (dry earth pigments); metal oxides; and organic colorants. The time period of the included studies extended from 2013 to 2023. Electronic database search identified a total of 217 studies. Ten studies were included to meet the research question. All 10 included studies analyzed the effect of various colorants and their exposure to various aging and weathering conditions. It was found that various pigments and nanoparticles had an effect on the color stability. Also weathering and aging conditions had a direct effect on the color stability as well. In terms of disinfection, although there was not much color difference observed, highest change in color stability was observed when rubbing or brushing of the prosthesis was carried out. In conclusion, the color stability of maxillofacial prosthetics is a critical factor that influences both patient satisfaction and the overall cosmetic look. The potential of pigments and nanoparticles to enhance the color stability of silicone-based maxillofacial prosthesis has received much research. By avoiding color fading and discoloration brought on by environmental variables including UV radiation, aging, and chemical exposure, the inclusion of various pigments and nanoparticles has been demonstrated to improve the color stability of silicone maxillofacial prostheses.


Assuntos
Prótese Maxilofacial , Pigmentação em Prótese , Humanos , Elastômeros de Silicone , Cor , Próteses e Implantes , Teste de Materiais
6.
Am J Dent ; 37(1): 53-56, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38458984

RESUMO

PURPOSE: To evaluate flow profile and non-Newtonian behavior of 10 different silicone lining materials. METHODS: Ten commercially available silicone lining materials were selected for evaluation. The flow profile and non-Newtonian behavior of each material was measured using a shark fin testing method. Fin height and resultant base thickness were measured with a digital caliper and compared with one-way ANOVA and Student-Newman-Keuls post hoc test and fin base by Kruskal-Wallis one-way ANOVA on ranks with Dunn post hoc test with significance at P< 0.05 for both. RESULTS: Shark fin heights ranged from 9.62 ± 0.86 mm [Reline II (Soft)] to 25.54 ± 0.43 mm [Sofreliner (Medium)]. Shark fin bases ranged from 2.57 ± 0.51 mm [Sofreliner (Medium)] to 10.31 ± 0.57 mm [Reline II (Soft)]. Statistically significant differences were found between certain samples' shark fin heights as well as resultant bases (P< 0.05) indicating different rheological properties. CLINICAL SIGNIFICANCE: Silicone liner materials differ significantly with respect to flow profile and non-Newtonian behavior. While a high flow profile (low viscosity) of an elastomeric impression material improves accuracy, it may be a detriment to a denture lining material that must achieve a critical minimum thickness to provide resilience. Likewise, a low flow profile (high viscosity) material may also pose a disadvantage, requiring excessive compression and possible tissue distortion to achieve the same critical thickness. The results of this study should be considered when selecting the appropriate material for clinical application. Additional studies are indicated to further quantify rheological properties as well as correlate them to physical properties after the complete cure of the material.


Assuntos
Reembasadores de Dentadura , Silicones , Humanos , Viscosidade , Teste de Materiais , Bases de Dentadura , Elastômeros de Silicone , Propriedades de Superfície
7.
J Biomed Mater Res B Appl Biomater ; 112(2): e35377, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38359174

RESUMO

Silicone rubber (SR), a common medical-grade polymer used in medical devices, has previously been modified for nitric oxide (NO) releasing capabilities. However, the effects of material properties such as film thickness on NO release kinetics are not well explored. In this study, SR is used in the first analysis of how a polymer's thickness affects the storage and uptake of an NO donor and subsequent release properties. Observed NO release trends show that a polymer's thickness results in tunable NO release. These results indicate how crucial a polymer's thickness is to optimize the NO release in an efficient and effective method.


Assuntos
Óxido Nítrico , Elastômeros de Silicone , Doadores de Óxido Nítrico
8.
Artigo em Inglês | MEDLINE | ID: mdl-38306955

RESUMO

1,3-dichlorobenzene (1,3-DCB) is an aromatic solvent that might be formed during thermal decomposition of bis(2,4-dichlorobenzoyl)peroxide used as initiator in silicone rubber production with many workers exposed worldwide. During metabolism of 1,3-DCB, two isomeric mercapturic acids can be formed from ring oxidation of 1,3-DCB in the liver, namely 2,4-dichlorophenylmercapturic acid (24CPhMA) and 3,5-dichlorophenylmercapturic acid (35CPhMA). These urinary mercapturic acids might serve as biomarkers of the toxicologically relevant absorbed dose of 1,3-DCB and have not been determined so far. Thus, we were aimed to develop an analytical method for quantification of these biomarkers. Authentic standards of both mercapturic acids as well as deuterium-labelled analogues were self-synthesized. A method for the quantification of both CPhMAs in human urine using online-SPE LC/MS/MS was developed and validated with an LOQ of 0.1 ng mL-1 for both CPhMAs. The analytes were extracted from urine by online-SPE on a restricted access material phase, transferred to the analytical column and quantified by tandem mass spectrometry. Interday (n = 6) and Intraday (n = 10) precision for both CPhMAs ranged from 1.7 to 4.3 % with accuracies between 99.4 and 109.9 % at concentrations of 0.6 and 3 ng mL-1. We applied the method on post-shift urine samples of 16 workers of the silicone rubber industry with occupational exposure to 1,3-DCB. Both CPhMAs were above LOQ in 15 of 16 urine samples with median levels (range) for 24CPhMA and 35CPhMA of 1.64 ng mL-1 (<0.1 - 8.2 ng mL-1) and 3.98 ng mL-1 (0.36 - 24.1 ng mL-1), respectively. This is the first report on specific urinary mercapturic acids of 1,3-DCB in humans. Our results show that ring oxidation of 1,3-DCB is considered to be a toxicologically relevant metabolic pathway in humans. This might improve risk assessment of 1,3-DCB-emissions in silicone rubber industry.


Assuntos
Clorobenzenos , Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Acetilcisteína/química , Elastômeros de Silicone , Biomarcadores/urina , Isótopos
9.
Technol Cancer Res Treat ; 23: 15330338241229367, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38297814

RESUMO

Objective: To investigate the dosimetric effects of using individualized silicone rubber (SR) bolus on the target area and organs at risk (OARs) during postmastectomy radiotherapy (PMRT), as well as evaluate skin acute radiation dermatitis (ARD). Methods: A retrospective study was performed on 30 patients with breast cancer. Each patient was prepared with an individualized SR bolus of 3 mm thickness. Fan-beam computed tomography (FBCT) was performed at the first and second fractions, and then once a week for a total of 5 times. Dosimetric metrics such as homogeneity index (HI), conformity index (CI), skin dose (SD), and OARs including the heart, lungs, and spinal cord were compared between the original plan and the FBCTs. The acute side effects were recorded. Results: In targets' dosimetric metrics, there were no significant differences in Dmean and V105% between planning computed tomography (CT) and actual treatments (P > .05), while the differences in D95%, V95%, HI, and CI were statistically significant (P < .05). In OARs, there were no significant differences between the Dmean, V5, and V20 of the affected lung, V5 of the heart and Dmax of the spinal cord (P > .05) except the V30 of affected lung, which was slightly lower than the planning CT (P < .05). In SD, both Dmax and Dmean in actual treatments were increased than plan A, and the difference was statistically significant (P < .05), while the skin-V20 and skin-V30 has no difference. Among the 30 patients, only one patient had no skin ARD, and 5 patients developed ARD of grade 2, while the remaining 24 patients were grade 1. Conclusion: The OR bolus showed good anastomoses and high interfraction reproducibility with the chest wall, and did not cause deformation during irradiation. It ensured accurate dose delivery of the target and OARs during the treatment, which may increase SD by over 101%. In this study, no cases of grade 3 skin ARD were observed. However, the potential of using OR bolus to reduce grade 1 and 2 skin ARD warrants further investigation with a larger sample size.


Assuntos
Neoplasias da Mama , Dermatite , Radioterapia de Intensidade Modulada , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Elastômeros de Silicone , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Estudos Retrospectivos , Reprodutibilidade dos Testes , Mastectomia/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X , Dermatite/cirurgia , Órgãos em Risco/efeitos da radiação
10.
Photodiagnosis Photodyn Ther ; 45: 103976, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224726

RESUMO

BACKGROUND: Urethral injury occurs in 1-6 % of male cases during minimally invasive surgery of lower rectal cancer. A Foley catheter emitting near-infrared (NIR) fluorescence of sufficient intensity has been expected to locate the urethra during image-guided surgery. Although it has been difficult to impart NIR fluorescent properties to biocompatible thermosetting polymers, we have recently succeeded in developing a NIR fluorescent compound for silicone rubber and a NIR fluorescent Foley catheter (HICARL). Here, we evaluated its NIR fluorescence properties and visibility performance using porcine anorectal isolation specimens. METHODS: The HICARL catheter was made of a mixture of solid silicone rubber and a NIR fluorescent compound that emits fluorescence with a wavelength of 820-880 nm, while a conventional transparent Foley catheter was made of solid silicone rubber only. As a standard for comparison of the intensity of NIR fluorescence, a transparent Foley catheter the lumen of which was filled with a mixture of indocyanine green (ICG) and human plasma was used. As a comparison to assess the visibility performance of the HICARL catheter, a transparent Foley catheter into which a commercially available NIR fluorescent polyurethane ureteral catheter (NIRC) was placed was used. RESULTS: A NIR fluorescence quantitative imaging analysis revealed that the Foley-NIRC catheter and the HICARL catheter emitted 3.42 ± 0.42 and 6.43 ± 0.07 times more fluorescence than the Foley-ICG catheter, respectively. The location of the HICARL catheter placed in the anorectum with a wall thickness of 3.8 ± 0.1 mm was clearly delineated in its entirety by NIR fluorescence, while that of the Foley-NIRC catheter was faintly or only partially visible. CONCLUSIONS: The HICARL catheter emitting NIR fluorescence of sufficient intensity is a promising and easy-to-use tool for urethral visualization during image-guided surgery of lower rectal cancer.


Assuntos
Fotoquimioterapia , Neoplasias Retais , Cirurgia Assistida por Computador , Humanos , Masculino , Animais , Suínos , Elastômeros de Silicone , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Corantes , Verde de Indocianina/farmacologia , Catéteres , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/cirurgia
11.
J Prosthet Dent ; 131(2): 340.e1-340.e6, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38212157

RESUMO

STATEMENT OF PROBLEM: Part 1 of this 2-part study determined that microwave disinfection did not degrade the color stability of facial silicone prostheses. However, investigations on the effects of microwave disinfection on the mechanical properties of different silicone elastomers are lacking. PURPOSE: The purpose of this in vitro study was to examine the mechanical properties of commonly used colored facial silicone elastomers before and after microwave disinfection over a simulated 1.5-year period. MATERIAL AND METHODS: Six commonly used facial silicone elastomers: MDX4-4210, MDX4-4210/Type A, M511, A-2186, VST-50, and A-2000 were combined with functional intrinsic silicone pigments and opacifier (red, yellow, blue, and white). A total of 288 specimens were fabricated (n=12). Half of the specimens were tested for mechanical properties as the baseline, while the other specimens were tested after microwave disinfection. Microwave disinfection was performed with 660 W, 6 minutes of exposure time, and microwaved for 18 cycles to simulate 1.5 years of usage (one 6-minute exposure monthly). For mechanical property testing, all specimens were tested for tensile strength and percentage elongation (ASTM D412), tear strength (ASTM D624), and hardness (ASTM D2240). For each property, a 2-way ANOVA (silicone type and microwave disinfection factors) and Tukey multiple comparison test were performed using the R statistical software program (α=.05). RESULTS: Following microwave disinfection, tensile strength and percentage elongation of A-2000 increased significantly (P<.05). MDX4-4210, MDX4-4210/Type A, and A-2000 showed significant increases in their hardness (P<.001). Tear strength also increased significantly for MDX4-4210 and VST-50 (P<.05). Among the materials tested (ranked from highest to lowest value,=not statistically significant different), for tensile strength, VST-50>A-2186=A-2000>MDX4-4210/Type A=M511=MDX4-4210 (P<.05). For percentage elongation, VST-50>MDX4-4210/Type A>A-2186>M511=A-2000=MDX4-4210=M511 (P<.05). For hardness, A-2000=A-2186>M511=VST-50>MDX4-4210>MDX4-4210/Type A (P<.05). For tear strength, VST-50>A-2186>A-2000>M511>MDX4-4210/Type A=MDX4-4210 (P<.05). CONCLUSIONS: Overall, the mechanical properties of all the silicones tested were not adversely affected by microwave disinfection. VST-50 showed the best mechanical properties among the materials tested both before and after microwave disinfection. Microwave energy is a safe method of disinfecting the silicone elastomers tested in this study.


Assuntos
Implantes Dentários , Dimetilpolisiloxanos , Prótese Maxilofacial , Elastômeros de Silicone , Desinfecção , Teste de Materiais , Micro-Ondas/uso terapêutico , Resistência à Tração
12.
Int J Prosthodont ; 37(1): 41-48, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37222545

RESUMO

PURPOSE: To evaluate the effect of adding tea tree oil to denture liners on Candida albicans and bond strength to the acrylic denture base. MATERIALS AND METHODS: Disc-shaped specimens were fabricated from silicone-based resilient liner (Tokuyama, Molloplast), acrylic-based hard liner (GC Reline), and acrylic-based soft liner (Visco-gel). Tea tree oil (TTO) was incorporated into the liners at varying concentrations (0% [control], 2%, 5%, 8%). C albicans were counted by viable colony count, and optical density (OD) was measured with a spectrophotometer. The tensile strength to heat polymerized acrylic denture base was measured in a universal testing machine. The compliance of the data to the distribution of normality was evaluated using the Shapiro Wilk test. Two-way ANOVA, Bonferroni correction, and paired sample t test were performed (α = .05). RESULTS: The addition of TTO into liners provided a significant decrease in the OD values (P < .001). The control groups of the liners presented the highest colony counts, whereas increasing TTO decreased the results (P < .01). According to tensile bond strength test, 8% TTO addition resulted in a significant decrease for Tokuyama (P < .01) and Molloplast liners (P < .05), while 2% TTO resulted in significance for GC Reline (P < .001). CONCLUSIONS: Denture liners containing increasing percentages of TTO presented lower amounts of C albicans colonies and decreased bond strength to the denture bases. When using TTO for its antifungal properties, the amount added should be carefully selected because the tensile bond strength may be affected.


Assuntos
Colagem Dentária , Reembasadores de Dentadura , Óleo de Melaleuca , Elastômeros de Silicone/química , Bases de Dentadura , Candida albicans , Óleo de Melaleuca/farmacologia , Resinas Acrílicas/química , Teste de Materiais , Polimetil Metacrilato , Resistência à Tração
13.
J Cataract Refract Surg ; 50(4): 394-400, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37994083

RESUMO

PURPOSE: To assess the complications that resulted in the explantation or secondary intervention with foldable intraocular lenses (IOLs). SETTING: University setting, Salt Lake City, Utah. DESIGN: Survey study. METHODS: For the 25th consecutive year, surgeons were surveyed regarding complications associated with foldable IOLs requiring explantation or secondary intervention over the 2022 calendar year. These forms were made available online using the ASCRS and ESCRS websites and a fax-on-demand service. Surgeons completed 1 survey for each foldable IOL requiring explantation or secondary intervention. Further analysis determined complication trends related to specific IOL styles, materials, and types over the past 16 years (2007 to 2022). RESULTS: 103 completed surveys were returned in 2022 contributing to a total of 1627 tabulated surveys since 2007. In the 2022 survey, dislocation/decentration continued to be the most common complication overall. Glare/optical aberrations was a common complication associated with multifocal IOLs continuing a 16-year trend. In addition, hydrophilic acrylic IOLs as well as some silicone lenses in eyes with asteroid hyalosis demonstrated calcification as the most common complication necessitating explantation. CONCLUSIONS: Dislocation/decentration remains the leading cause of explantation in most IOL types. Glare/optical aberrations continue to be an associated complication of multifocal IOLs suggesting this ongoing issue has yet to be resolved with this type of IOL. In addition, calcification of hydrophilic acrylic lenses and silicone lenses is a rare event but continues to occur.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Lentes Intraoculares/efeitos adversos , Inquéritos e Questionários , Silicones , Remoção de Dispositivo , Elastômeros de Silicone
14.
Clin Pharmacol Ther ; 115(5): 1085-1091, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38159264

RESUMO

Episil is a bioadhesive barrier-forming liquid gel that can relieve mucositis caused by radiotherapy (RT) and effectively relieve pain. The purpose of this trial is to compare the efficacy and safety of Episil in improving acute radiation dermatitis (ARD) in patients with breast cancer. This study included patients who met the criteria for postoperative RT for breast cancer. The primary end point was the grade of RD during treatment. A total of 102 patients were included in this study. The patients were grouped in a 2:1 ratio using the randomized number table method: 67 patients received Episil combined with conventional skin care (the Episil group), whereas the remaining 35 patients served as the control group and received conventional skin care only (the control group). According to the grading criteria of the Radiation Therapy Oncology Group (RTOG), the skin reaction rate and severity were significantly better in the Episil group than the control group (24.62%, 72.31%, 3.08, 0, 0 vs. 0, 85.71%, 14.29%, 0, 0, 0) across grades 0 to 4 (P < 0.05). The itchiness score exhibited s significant reduction in the Episil group as compared with the control group (P < 0.05). The results of the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) showed that the overall health (z = -5.855, P < 0.001) and overall quality of life (z = -6.583, P < 0.001) were better in the Episil group than the control group after RT. Overall, in patients with breast cancer receiving RT, the topical application of Episil may significantly reduce the grading of ARD, alleviate patient symptoms, and improve the patient's overall quality of life.


Assuntos
Neoplasias da Mama , Radiodermite , Elastômeros de Silicone , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Qualidade de Vida , Radiodermite/tratamento farmacológico , Dor
15.
Int J Biol Macromol ; 258(Pt 2): 129110, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38161016

RESUMO

Polymer modification using silicone rubber represents a promising avenue for enhancing physico-mechanical properties. However, achieving optimal performance through direct blending is hindered by the poor interface compatibility between silicone rubber and the matrix. In this study, we prepared super-tough thermoplastic vulcanizates (TPVs) of polylactic acid/silicone rubber through dynamic vulcanization with PLA, methyl vinyl silicone rubber (MVQ), glycidyl methacrylate grafted MVQ (MVQ-g-GMA), and fumed silica nanoparticles (SiO2). The impact of the SiO2 addition in MVQ on the morphology, mechanical properties, crystallization, and thermal properties of the TPVs was investigated. The results showed that MVQ-g-GMA and SiO2 exhibited a synergistic compatibilization effect significantly improving the interfacial adhesion between PLA and MVQ. Therefore, the impact and tensile strength of the TPVs increased from 8.0 kJ/m2 and 22.2 MPa to 62.6 kJ/m2 and 36.7 MPa, respectively. Moreover, the TPVs also presented good low-temperature toughness with a maximum impact strength of 40.4 kJ/m2 at -20 °C. Additionally, improvements in thermal stability and crystallization rate were also observed. Overall, combining organic and inorganic synergistic compatibilization is a feasible and effective method to fabricate outstanding low-temperature toughness to PLA.


Assuntos
Dióxido de Silício , Elastômeros de Silicone , Poliésteres , Polímeros
16.
Int J Mol Sci ; 24(23)2023 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-38068948

RESUMO

The aim of this research was to obtain new polymer composites with a silicone rubber matrix, having favorable mechanical and functional properties. They contained admixtures in the amount of 10% by weight of expanded graphite (EG) or birch bark (BB). Additionally, some composites contained magnetic particles in the form of carbonyl iron in the amount of 20% by weight. The tensile strength, water absorption, frost resistance, surface contact angle, and free surface energy were examined. Microscopic images were taken using the SEM method and the content of some elements in selected microareas was determined using the EDXS method. In the study, a constant magnetic field with magnetic induction B was used, by means of which the properties and structure of polymer composites were modified. Scientific research in the field of polymers is the driving force behind the progress of civilization. Smart materials are able to respond to external stimuli, such as magnetic fields, with significant changes in their properties. The magnetic field affects not only chemical reactions, but also the crystallographic structure and physicochemical properties of the final products. Owing to their unique properties, such materials can be used in the space industry, automotive industry, or electrical engineering.


Assuntos
Polímeros , Elastômeros de Silicone , Polímeros/química , Elastômeros de Silicone/química , Fenômenos Químicos , Água , Campos Magnéticos
17.
Medicina (Kaunas) ; 59(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38003985

RESUMO

Background and Objectives: One's quality of life depends on overall health, and in particular, oral health, which has been and continues to become a public health issue through frequent manifestations in various forms, from simple oral stomatitis (inflammations of the oral cavity) to the complicated oral health pathologies requiring medical interventions and treatments (caries, pulp necrosis and periodontitis). The aim of this study focused on the preparation and evaluation of vitamins (vitamin A, B1 and B6) incorporated into several silicone-based lining materials as a new alternative to therapeutically loaded materials designed as oral cavity lining materials in prosthodontics. Materials and Methods: Silicone-based liners containing vitamins were prepared by mixing them in solution and becoming crosslinked, and then they were characterized using Fourier-transform infrared (FT-IR) spectroscopy to confirm the incorporation of the vitamins into the silicone network; scanning electron microscopy (SEM) to evidence the morphology of the liner materials; dynamic vapor sorption (DVS) to evaluate their internal hydrophobicity, swelling in environments similar to biological fluids and mechanical test to demonstrate tensile strength; MTT to confirm their biocompatibility on normal cell cultures (fibroblast) and mucoadhesivity; and histopathological tests on porcine oral mucosa to highlight their potential utility as soft lining materials with improved efficiency. Results: FT-IR analysis confirmed the structural peculiarities of the prepared lining materials and the successful incorporation of vitamins into the silicone matrix. The surface roughness of the materials was lower than 0.2 µm, while in cross-section, the lining materials showed a compact morphology. It was found that the presence of vitamins induced a decrease in the main mechanical parameters (strength and elongation at break, Young's modulus) and hydrophobicity, which varied from one vitamin to another. A swelling degree higher than 8% was found in PBS 6.8 (artificial saliva) and water. Hydrolytic stability studies in an artificial saliva medium showed the release of low concentrations of silicone and vitamin fragments in the first 24 h, which increased the swelling behavior of the materials, diffusion and solubility of the vitamins. The microscopic images of fibroblast cells incubated with vitamin liners revealed very good biocompatibility. Also, the silicone liners incorporating the vitamins showed good mucoadhesive properties. The appearance of some pathological disorders with autolysis processes was more pronounced in the case of vitamin A liners. Conclusions: The addition of the vitamins was shown to have a beneficial effect that was mainly manifested as increased biocompatibility, hydrolytic stability and mucoadhesiveness with the mucosa of the oral cavity and less of an effect on the mechanical strength. The obtained lining materials showed good resistance in simulated biological media but caused a pronounced autolysis phenomenon, as revealed by histopathological examination, showing that these materials may have broad implications in the treatment of oral diseases.


Assuntos
Reembasadores de Dentadura , Elastômeros de Silicone , Animais , Suínos , Elastômeros de Silicone/química , Vitaminas , Vitamina A , Mucosa Bucal , Qualidade de Vida , Saliva Artificial , Espectroscopia de Infravermelho com Transformada de Fourier , Teste de Materiais , Vitamina K
18.
Clin Oral Investig ; 27(12): 7799-7807, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919552

RESUMO

OBJECTIVE: The aim of this in vitro study was to evaluate the effect of an oxide nanocoating to prevent colour degradation of maxillofacial silicone elastomers following accelerated ageing. MATERIAL AND METHODS: Specimens (N = 40) of specified dimensions were fabricated in Factor II room temperature vulcanizing (RTV) silicone and processed according to the manufacturer's instructions. Two groups were classified with 20 specimens each. Specimens in the first group were coated with titanium dioxide (TiO2) by atomic layer deposition technology. The colour stability test was conducted with a UV-VIS spectrometer (Schimadzu) for both titanium dioxide nanocoated and uncoated specimen groups after subjecting them to accelerated ageing. It was analysed using the CIE L*a*b method. RESULTS: The average colour change was highest for uncoated specimens (2.868), and the average colour change for titanium dioxide-coated specimens was significantly low (1.774). The average colour change of uncoated specimens (2.868) was close to the acceptable threshold value (3), and that of coated specimens (1.774) was far below the acceptable threshold (3). CONCLUSIONS: The colour change that occurred in titanium dioxide nanocoated specimens following accelerated ageing was significantly lower than that in the uncoated group, showing that the TiO2 nanocoating was effective in reducing the colour degradation of silicone elastomers. CLINICAL RELEVANCE: Maxillofacial prostheses fabricated from silicone elastomers go through undesirable colour degradation over time. The development of a scientific technique that retards the colour deterioration of silicone prostheses would be of great clinical significance.


Assuntos
Elastômeros de Silicone , Cor , Temperatura , Teste de Materiais
19.
Biomater Sci ; 11(22): 7311-7326, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37847519

RESUMO

Rosin is a characteristic natural renewable resource. In view of the unique hydrogenated phenanthrene ring skeleton structure of rosin, it can be designed and synthesized to modify silicone rubber for improving its mechanical properties, thermal stability, and other properties. In this paper, the research progress of silicone rubber modified by rosin and its derivatives is reviewed, including internal or surface modification of room temperature or high temperature vulcanized silicone rubber. The different chemical modifications and polymerization pathways to obtain bio-based silicone rubber (e.g. rosin-based silicone cross-linking agent, filler compound rosin-based silicone cross-linking agent, rosin-based polymer, and rosin quaternary ammonium salt bifunctional antibacterial coating) are discussed and its research prospect is reviewed. Overall, the present review article will provide a quantitative experimental basis for rosin to produce bio-renewable multifunctional silicone rubber to increase our level of understanding of the behavior of this important class of silicone rubber and other similar bio-based polymers.


Assuntos
Resinas Vegetais , Elastômeros de Silicone , Elastômeros de Silicone/química , Resinas Vegetais/química , Antibacterianos , Polímeros/química
20.
Shanghai Kou Qiang Yi Xue ; 32(3): 251-254, 2023 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-37803978

RESUMO

PURPOSE: To evaluate the effect of different kinds of gingival retraction agents after directly contacted with polyvinyl siloxane impression materials on polymerization inhibition and the inhibition degree. METHODS: Five kinds of gingival retraction agents (0.1% epinephrine hydrochloride, 0.05% oxymetazoline, 15.5% ferric sulfate, 25% aluminum chloride and 5% aluminum chloride) were chosen, normal saline was as control group, and two kinds of polyvinyl siloxane impression materials (ExpressTM, ImprintTM Ⅱ) were combined into 12 groups. There were 12 specimens in each group and 144 specimens in total. Silicone rubber impression materials were mixed by the same operator using a dispensing gun into the acrylic mold, so that they could directly contact the gingival retraction agents on the densely woven cotton fabrics. The samples were removed when the polymerization time arrived according to the manufactures' recommendations and then placed under a stereomicroscope with a magnification of 10 times to observe whether polymerization inhibition occurred, the degree of inhibition was compared afterwards. SPSS 22.0 software package was used for statistical analysis. RESULTS: The polymerization inhibition of two kinds of silicone rubber impression materials occurred in 15.5% ferric sulfate group and 25% aluminum chloride group, and the inhibition occurrence rate was 100%, the difference was statistically significant (P<0.05) compared with normal saline group. Inhibition was not found in 0.1% epinephrine hydrochloride group, 0.05% oxymetazoline group and 5% aluminum chloride. The effect of 15.5% ferric sulfate and 25% aluminum chloride on polymerization inhibition degree of ImprintTM Ⅱ was greater than ExpressTM, and the difference was statistically significant(P<0.05). CONCLUSIONS: When silicone rubber impression material is used during impression procedure, attention should be paid to the effect of the gingival retraction agent containing 15.5% ferric sulfate and 25% aluminum chloride on its polymerization. The gingival retraction agent should be washed before impression to avoid the residue directly contacting the silicone rubber to prevent polymerization.


Assuntos
Oximetazolina , Elastômeros de Silicone , Cloreto de Alumínio , Elastômeros de Silicone/química , Polimerização , Solução Salina , Materiais para Moldagem Odontológica/química , Epinefrina/química , Técnica de Moldagem Odontológica