Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.970
Filtrar
1.
PLoS One ; 19(5): e0301041, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38701088

RESUMO

OBJECTIVE: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. RESEARCH DESIGN AND METHODS: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40-400 mg/dL, 2.2-22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4-8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. RESULTS: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. CONCLUSIONS: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. TRIAL REGISTRATION: Clinical trial identifier: NCT04782934.


Assuntos
Etanol , Estudos de Viabilidade , Cetonas , Ácido Láctico , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Cetonas/análise , Masculino , Etanol/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Feminino , Ácido Láctico/análise , Ácido Láctico/sangue , Glicemia/análise , Pessoa de Meia-Idade , Diabetes Mellitus Tipo 1/sangue , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Glucose/análise
2.
Sci Rep ; 14(1): 11287, 2024 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760449

RESUMO

Spectrum power analysis in the low frequency oscillations (LFO) region of functional near infrared spectroscopy (fNIRS) is a promising method to deliver information about brain activation and therefore might be used for prognostication in patients with disorders of consciousness in the neurocritical care unit alongside with established methods. In this study, we measure the cortical hemodynamic response measured by fNIRS in the LFO region following auditory and somatosensory stimulation in healthy subjects. The significant hemodynamic reaction in the contralateral hemisphere correlation with the physiologic electric response suggests neurovascular coupling. In addition, we investigate power spectrum changes in steady state measurements of cerebral death patients and healthy subjects in the LFO region, the frequency of the heartbeat and respiration. The spectral power within the LFO region was lower in the patients with cerebral death compared to the healthy subjects, whereas there were no differences in spectral power for physiological activities such as heartbeat and respiration rate. This finding indicates the cerebral origin of our low frequency measurements. Therefore, LFO measurements are a potential method to detect brain activation in patients with disorders of consciousness and cerebral death. However, further studies in patients are needed to investigate its potential clinical use.


Assuntos
Morte Encefálica , Acoplamento Neurovascular , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Feminino , Adulto , Acoplamento Neurovascular/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Morte Encefálica/fisiopatologia , Pessoa de Meia-Idade , Hemodinâmica/fisiologia , Idoso , Encéfalo/fisiopatologia , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Frequência Cardíaca/fisiologia
3.
Cereb Cortex ; 34(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38725293

RESUMO

Numerous studies reported inconsistent results concerning gender influences on the functional organization of the brain for language in children and adults. However, data for the gender differences in the functional language networks at birth are sparse. Therefore, we investigated gender differences in resting-state functional connectivity in the language-related brain regions in newborns using functional near-infrared spectroscopy. The results revealed that female newborns demonstrated significantly stronger functional connectivities between the superior temporal gyri and middle temporal gyri, the superior temporal gyri and the Broca's area in the right hemisphere, as well as between the right superior temporal gyri and left Broca's area. Nevertheless, statistical analysis failed to reveal functional lateralization of the language-related brain areas in resting state in both groups. Together, these results suggest that the onset of language system might start earlier in females, because stronger functional connectivities in the right brain in female neonates were probably shaped by the processing of prosodic information, which mainly constitutes newborns' first experiences of speech in the womb. More exposure to segmental information after birth may lead to strengthened functional connectivities in the language system in both groups, resulting in a stronger leftward lateralization in males and a more balanced or leftward dominance in females.


Assuntos
Idioma , Caracteres Sexuais , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Feminino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Recém-Nascido , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Descanso/fisiologia , Lateralidade Funcional/fisiologia , Vias Neurais/fisiologia , Mapeamento Encefálico/métodos
4.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38707651

RESUMO

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Assuntos
Circulação Cerebrovascular , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Feminino , Masculino , Adulto , Circulação Cerebrovascular/fisiologia , Hemodinâmica/fisiologia , Oximetria/métodos , Oximetria/instrumentação , Oxigênio/sangue , Oxigênio/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Desenho de Equipamento
5.
Food Res Int ; 186: 114401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38729704

RESUMO

Fuzhuan brick tea (FBT) fungal fermentation is a key factor in achieving its unique dark color, aroma, and taste. Therefore, it is essential to develop a rapid and reliable method that could assess its quality during FBT fermentation process. This study focused on using electronic nose (e-nose) and spectroscopy combination with sensory evaluations and physicochemical measurements for building machine learning (ML) models of FBT. The results showed that the fused data achieved 100 % accuracy in classifying the FBT fermentation process. The SPA-MLR method was the best prediction model for FBT quality (R2 = 0.95, RMSEP = 0.07, RPD = 4.23), and the fermentation process was visualized. Where, it was effectively detecting the degree of fermentation relationship with the quality characteristics. In conclusion, the current study's novelty comes from the established real-time method that could sensitively detect the unique post-fermentation quality components based on the integration of spectral, and e-nose and ML approaches.


Assuntos
Nariz Eletrônico , Fermentação , Espectroscopia de Luz Próxima ao Infravermelho , Paladar , Chá , Chá/química , Chá/microbiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Odorantes/análise , Quimiometria/métodos , Humanos , Fungos/metabolismo , Aprendizado de Máquina , Compostos Orgânicos Voláteis/análise
6.
Food Res Int ; 186: 114320, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38729710

RESUMO

High-moisture extrusion (HME) is widely used to produce meat analogues. During HME the plant-based materials experience thermal and mechanical stresses. It is complicated to separate their effects on the final products because these effects are interrelated. In this study we hypothesize that the intensity of the thermal treatment can explain a large part of the physicochemical changes that occur during extrusion. For this reason, near-infrared (NIR) spectroscopy was used as a novel method to quantify the thermal process intensity during HME. High-temperature shear cell (HTSC) processing was used to create a partial least squares (PLS) regression curve for processing temperature under controlled processing conditions (root mean standard error of cross-validation (RMSECV) = 4.00 °C, coefficient of determination of cross-validation (R2CV) = 0.97). This PLS regression model was then applied to HME extrudates produced at different screw speeds (200-1200 rpm) and barrel temperatures (100-160 °C) with two different screw profiles to calculate the equivalent shear cell temperature as a measure for thermal process intensity. This equivalent shear cell temperature reflects the effects of changes in local temperature conditions, residence time and thermal stresses. Furthermore, it can be related to the degree of texturization of the extrudates. This information can be used to gain new insights into the effect of various process parameters during HME on the thermal process intensity and extrudate quality.


Assuntos
Manipulação de Alimentos , Temperatura Alta , Proteínas de Soja , Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Manipulação de Alimentos/métodos , Proteínas de Soja/química , Proteínas de Soja/análise , Análise dos Mínimos Quadrados , Água/química
7.
Sci Rep ; 14(1): 10426, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714752

RESUMO

Discriminating different cultivars of maca powder (MP) and detecting their authenticity after adulteration with potent adulterants such as maize and soy flour is a challenge that has not been studied with non-invasive techniques such as near infrared spectroscopy (NIRS). This study developed models to rapidly classify and predict 0, 10, 20, 30, 40, and 50% w/w of soybean and maize flour in red, black and yellow maca cultivars using a handheld spectrophotometer and chemometrics. Soy and maize adulteration of yellow MP was classified with better accuracy than in red MP, suggesting that red MP may be a more susceptible target for adulteration. Soy flour was discovered to be a more potent adulterant compared to maize flour. Using 18 different pretreatments, MP could be authenticated with R2CV in the range 0.91-0.95, RMSECV 6.81-9.16 g/,100 g and RPD 3.45-4.60. The results show the potential of NIRS for monitoring Maca quality.


Assuntos
Aprendizado de Máquina , Pós , Espectroscopia de Luz Próxima ao Infravermelho , Zea mays , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Zea mays/química , Espectrofotometria/métodos , Macau , Contaminação de Alimentos/análise , Glycine max/química , Farinha/análise
8.
PLoS One ; 19(5): e0302828, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722930

RESUMO

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Assuntos
Hemodinâmica , Músculo Esquelético , Oxiemoglobinas , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Hemodinâmica/fisiologia , Feminino , Adulto , Músculo Esquelético/fisiologia , Músculo Esquelético/irrigação sanguínea , Oxiemoglobinas/metabolismo , Oxiemoglobinas/análise , Ventosaterapia/métodos , Adulto Jovem , Hemoglobinas/metabolismo
9.
Cereb Cortex ; 34(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38715408

RESUMO

Speech comprehension in noise depends on complex interactions between peripheral sensory and central cognitive systems. Despite having normal peripheral hearing, older adults show difficulties in speech comprehension. It remains unclear whether the brain's neural responses could indicate aging. The current study examined whether individual brain activation during speech perception in different listening environments could predict age. We applied functional near-infrared spectroscopy to 93 normal-hearing human adults (20 to 70 years old) during a sentence listening task, which contained a quiet condition and 4 different signal-to-noise ratios (SNR = 10, 5, 0, -5 dB) noisy conditions. A data-driven approach, the region-based brain-age predictive modeling was adopted. We observed a significant behavioral decrease with age under the 4 noisy conditions, but not under the quiet condition. Brain activations in SNR = 10 dB listening condition could successfully predict individual's age. Moreover, we found that the bilateral visual sensory cortex, left dorsal speech pathway, left cerebellum, right temporal-parietal junction area, right homolog Wernicke's area, and right middle temporal gyrus contributed most to prediction performance. These results demonstrate that the activations of regions about sensory-motor mapping of sound, especially in noisy conditions, could be sensitive measures for age prediction than external behavior measures.


Assuntos
Envelhecimento , Encéfalo , Compreensão , Ruído , Espectroscopia de Luz Próxima ao Infravermelho , Percepção da Fala , Humanos , Adulto , Percepção da Fala/fisiologia , Masculino , Feminino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Pessoa de Meia-Idade , Adulto Jovem , Idoso , Compreensão/fisiologia , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Envelhecimento/fisiologia , Mapeamento Encefálico/métodos , Estimulação Acústica/métodos
10.
PLoS One ; 19(5): e0302375, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38701103

RESUMO

There are numerous reports of enhanced or emerged visual arts abilities in patients with semantic impairment. These reports led to the theory that a loss of function on the language side of the brain can result in changes of ability to draw and/or to paint. Further, the left posterior middle temporal gyrus (l-pMTG) has been revealed to contribute to the higher control semantic mechanisms with objects recognition and integration of visual information, within a widely distributed network of the left hemisphere. Nevertheless, the theory has not been fully studied in neural bases. The aim of this study is to examine role of the l-pMTG on shape recognition and its reconstruction within drawing behavior, by using a combining method of the repetitive transcranial magnetic stimulation (rTMS) and functional near-infrared spectroscopy (fNIRS). Eighteen healthy participants received a low frequency inhibitory rTMS to their l-pMTG during the drawing task of the Benton Visual Retention Test (BVRT). There was a significant decrease of the mean accuracy of reproductions in the Complex designs of the BVRT, compared to the Simple and Medium designs. The fNIRS data showed strong negative correlations with the results of the BVRT. Though our hypothesis had a contradiction that rTMS would have inhibited the brain activity in the stimulated site, the results suggest that shape recognition and its reconstruction such as the BVRT require neural activations of the l-TL as well as that of the l-pMTG.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Lobo Temporal , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Lobo Temporal/fisiologia , Lobo Temporal/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Feminino , Adulto , Adulto Jovem , Reconhecimento Visual de Modelos/fisiologia , Mapeamento Encefálico/métodos
11.
BMJ Open ; 14(5): e079858, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724058

RESUMO

INTRODUCTION: Anastomotic leakage (AL) is defined as the failure of complete healing or disruption of the anastomosis subsequent to rectal cancer surgery, resulting in the extravasation of intestinal contents into the intra-abdominal or pelvic cavity. It is a serious complication of rectal cancer surgery, accounting for a considerable increase in morbidity and mortality. The use of fluorescence imaging technology in surgery allows surgeons to better evaluate blood perfusion. However, the conclusions of some existing studies are not consistent, so a consensus on whether the near-infrared indocyanine green (NIR-ICG) imaging system can reduce the incidence of AL is needed. METHODS: This POSTER trial is designed as a multicentre, prospective, randomised controlled clinical study adhering to the "population, interventions, comparisons, outcomes (PICO)" principles. It is scheduled to take place from August 2019 to December 2024 across eight esteemed hospitals in China. The target population consists of patients diagnosed with rectal cancer through pathological confirmation, with tumours located≤10 cm from the anal verge, eligible for laparoscopic surgery. Enrolled patients will be randomly assigned to either the intervention group or the control group. The intervention group will receive intravenous injections of ICG twice, with intraoperative assessment of anastomotic blood flow using the near-infrared NIR-ICG system during total mesorectal excision (TME) surgery. Conversely, the control group will undergo conventional TME surgery without the use of the NIR-ICG system. A 30-day follow-up period postoperation will be conducted to monitor and evaluate occurrences of AL. The primary endpoint of this study is the incidence of AL within 30 days postsurgery in both groups. The primary outcome investigators will be blinded to the application of ICG angiography. Based on prior literature, we hypothesise an AL rate of 10.3% in the control group and 3% in the experimental group for this study. With a planned ratio of 2:1 between the number of cases in the experimental and control groups, and an expected 20% lost-to-follow-up rate, the initial estimated sample size for this study is 712, comprising 474 in the experimental group and 238 in the control group. ETHICS AND DISSEMINATION: This study has been approved by Ethics committee of Beijing Friendship Hospital, Capital Medical University (approval number: 2019-P2-055-02). The results will be disseminated in major international conferences and peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04012645.


Assuntos
Fístula Anastomótica , Verde de Indocianina , Laparoscopia , Neoplasias Retais , Humanos , Verde de Indocianina/administração & dosagem , Neoplasias Retais/cirurgia , Neoplasias Retais/diagnóstico por imagem , Laparoscopia/métodos , Estudos Prospectivos , Fístula Anastomótica/prevenção & controle , Corantes , Feminino , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Masculino , China , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Pessoa de Meia-Idade
12.
PLoS One ; 19(5): e0303144, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38718035

RESUMO

Charitable fundraising increasingly relies on online crowdfunding platforms. Project images of charitable crowdfunding use emotional appeals to promote helping behavior. Negative emotions are commonly used to motivate helping behavior because the image of a happy child may not motivate donors to donate as willingly. However, some research has found that happy images can be more beneficial. These contradictory results suggest that the emotional valence of project imagery and how fundraisers frame project images effectively remain debatable. Thus, we compared and analyzed brain activation differences in the prefrontal cortex governing human emotions depending on donation decisions using functional near-infrared spectroscopy, a neuroimaging device. We advance existing theory on charitable behavior by demonstrating that little correlation exists in donation intentions and brain activity between negative and positive project images, which is consistent with survey results on donation intentions by victim image. We also discovered quantitative brain hemodynamic signal variations between donors and nondonors, which can predict and detect donor mental brain functioning using functional connectivity, that is, the statistical dependence between the time series of electrophysiological activity and oxygenated hemodynamic levels in the prefrontal cortex. These findings are critical in developing future marketing strategies for online charitable crowdfunding platforms, especially project images.


Assuntos
Emoções , Obtenção de Fundos , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Emoções/fisiologia , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Obtenção de Fundos/métodos , Feminino , Masculino , Adulto , Instituições de Caridade , Córtex Pré-Frontal/fisiologia , Córtex Pré-Frontal/diagnóstico por imagem , Intenção , Adulto Jovem , Mapeamento Encefálico/métodos , Crowdsourcing , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem
13.
PLoS One ; 19(5): e0304107, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38781193

RESUMO

AIM: In a previous study, we reported that watching two-dimensional videos of earthquakes significantly reduced sympathetic nerve activity in healthy young adults. In the present study, we aimed to investigate the emotional responses to earthquakes using immersive virtual reality (VR), which can provide a more realistic experience. METHODS: In total, 24 healthy young adults (12 males, 21.4 ± 0.2 years old) participated. Participants were required to watch earthquake and neutral videos while wearing a head-mounted display and near-infrared spectroscopy (NIRS), during which physiological signals, including pulse rate and cerebral blood flow (CBF) in the dorsolateral prefrontal cortex, were measured. We also analyzed changes in sympathetic and parasympathetic indices and obtained seven emotion ratings: valence, arousal, dominance, fear, astonishment, anxiety, and panic. RESULTS: The VR earthquake videos evoked negative subjective emotions, and the pulse rate significantly decreased. Sympathetic nerve activity tended to decrease, whereas CBF in the left prefrontal cortex showed a slight increase, although this was not significant. CONCLUSIONS: This study showed that measurements combined with NIRS and immersive VR have the potential to capture emotional responses to different stimuli.


Assuntos
Terremotos , Emoções , Frequência Cardíaca , Espectroscopia de Luz Próxima ao Infravermelho , Realidade Virtual , Humanos , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Emoções/fisiologia , Feminino , Adulto Jovem , Frequência Cardíaca/fisiologia , Circulação Cerebrovascular/fisiologia , Adulto , Córtex Pré-Frontal/fisiologia , Nível de Alerta/fisiologia
14.
PLoS One ; 19(5): e0304356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38781258

RESUMO

INTRODUCTION: Functional near-infrared spectroscopy (fNIRS) is a promising tool for studying brain activity, offering advantages such as portability and affordability. However, challenges in data collection persist due to factors like participant physiology, environmental light, and gross-motor movements, with limited literature on their impact on fNIRS signal quality. This study addresses four potentially influential factors-hair color, hair cleanliness, environmental light, and gross-motor movements-on fNIRS signal quality. Our aim is to raise awareness and offer insights for future fNIRS research. METHODS: Six participants (4 Females, 2 Males) took part in four different experiments investigating the effects of hair color, hair cleanliness, environmental light, and gross-motor movements on fNIRS signal quality. Participants in Experiment 1, categorized by hair color, completed a finger-tapping task in a between-subjects block design. Signal quality was compared between each hair color. Participants in Experiments 2 and 3 completed a finger-tapping task in a within-subjects block design, with signal quality being compared across hair cleanliness (i.e., five consecutive days without washing the hair) and environmental light (i.e., sunlight, artificial light, no light, etc.), respectively. Experiment 4 assessed three gross-motor movements (i.e., walking, turning and nodding the head) in a within-subjects block design. Motor movements were then compared to resting blocks. Signal quality was evaluated using Scalp Coupling Index (SCI) measurements. RESULTS: Lighter hair produced better signals than dark hair, while the impact of environmental light remains uncertain. Hair cleanliness showed no significant effects, but gross motor movements notably reduced signal quality. CONCLUSION: Our results suggest that hair color, environmental light, and gross-motor movements affect fNIRS signal quality while hair cleanliness does not. Nevertheless, future studies with larger sample sizes are warranted to fully understand these effects. To advance future research, comprehensive documentation of participant demographics and lab conditions, along with signal quality analyses, is essential.


Assuntos
Cor de Cabelo , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Feminino , Masculino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Cor de Cabelo/fisiologia , Luz , Adulto Jovem , Cabelo/química , Cabelo/fisiologia , Movimento/fisiologia , Movimento (Física)
15.
PLoS One ; 19(5): e0303983, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38781264

RESUMO

Despite accumulating evidence that blood flow restriction (BFR) training promotes muscle hypertrophy and strength gain, the underlying neurophysiological mechanisms have rarely been explored. The primary goal of this study is to investigate characteristics of cerebral cortex activity during BFR training under different pressure intensities. 24 males participated in 30% 1RM squat exercise, changes in oxygenated hemoglobin concentration (HbO) in the primary motor cortex (M1), pre-motor cortex (PMC), supplementary motor area (SMA), and dorsolateral prefrontal cortex (DLPFC), were measured by fNIRS. The results showed that HbO increased from 0 mmHg (non-BFR) to 250 mmHg but dropped sharply under 350 mmHg pressure intensity. In addition, HbO and functional connectivity were higher in M1 and PMC-SMA than in DLPFC. Moreover, the significant interaction effect between pressure intensity and ROI for HbO revealed that the regulation of cerebral cortex during BFR training was more pronounced in M1 and PMC-SMA than in DLPFC. In conclusion, low-load resistance training with BFR triggers acute responses in the cerebral cortex, and moderate pressure intensity achieves optimal neural benefits in enhancing cortical activation. M1 and PMC-SMA play crucial roles during BFR training through activation and functional connectivity regulation.


Assuntos
Córtex Cerebral , Córtex Motor , Treinamento Resistido , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Masculino , Treinamento Resistido/métodos , Adulto Jovem , Córtex Cerebral/fisiologia , Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/metabolismo , Córtex Cerebral/diagnóstico por imagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Córtex Motor/fisiologia , Córtex Motor/diagnóstico por imagem , Córtex Pré-Frontal/fisiologia , Córtex Pré-Frontal/irrigação sanguínea , Córtex Pré-Frontal/metabolismo , Córtex Pré-Frontal/diagnóstico por imagem
16.
Nano Lett ; 24(20): 6131-6138, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38727077

RESUMO

Accurate intraoperative tumor delineation is critical to achieving successful surgical outcomes. However, conventional techniques typically suffer from poor specificity and low sensitivity and are time-consuming, which greatly affects intraoperative decision-making. Here, we report a cascade activatable near-infrared fluorescent (NIRF) probe IR780SS@CaP that can sequentially respond to tumor acidity and elevated glutathione levels for accurate intraoperative tumor localization. Compared with nonactivatable and single-factor activatable probes, IR780SS@CaP with a cascade strategy can minimize nonspecific activation and false positive signals in a complicated biological environment, affording a superior tumor-to-normal tissue ratio to facilitate the delineation of abdominal metastases. Small metastatic lesions that were less than 1 mm in diameter can be precisely identified by IR780SS@CaP and completely excised under NIRF imaging guidance. This study could benefit tumor diagnosis and image-guided tumor surgery by providing real-time information and reliable decision support, thus reducing the risk of both recurrence and complications to improve patient outcomes.


Assuntos
Corantes Fluorescentes , Corantes Fluorescentes/química , Humanos , Animais , Camundongos , Imagem Óptica/métodos , Linhagem Celular Tumoral , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Cirurgia Assistida por Computador/métodos , Espectroscopia de Luz Próxima ao Infravermelho/métodos
17.
J Tradit Chin Med ; 44(3): 505-514, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38767634

RESUMO

OBJECTIVE: To evaluate the quality of Moyao (Myrrh) in the identification of the geographical origin and processing of the products. METHODS: Raw Moyao (Myrrh) and two kinds of Moyao (Myrrh) processed with vinegar from three countries were identified using near-infrared (NIR) spectroscopy combined with chemometric techniques. Principal component analysis (PCA) was used to reduce the dimensionality of the data and visualize the clustering of samples from different categories. A classical chemometric algorithm (PLS-DA) and two machine learning algorithms [K-nearest neighbor (KNN) and support vector machine] were used to conduct a classification analysis of the near-infrared spectra of the Moyao (Myrrh) samples, and their discriminative performance was evaluated. RESULTS: Based on the accuracy, precision, recall rate, and F1 value in each model, the results showed that the classical chemometric algorithm and the machine learning algorithm obtained positive results. In all of the chemometric analyses, the NIR spectrum of Moyao (Myrrh) preprocessed by standard normal variation or Multivariate scattering correction combined with KNN achieved the highest accuracy in identifying the geographical origins, and the accuracy of identifying the processing technology established by the KNN method after first-order derivative pretreatment was the best. The best accuracy of geographical origin discrimination and processing technology discrimination were 0.9853 and 0.9706 respectively. CONCLUSIONS: NIR spectroscopy combined with chemometric technology can be an important tool for tracking the origin and processing technology of Moyao (Myrrh) and can also provide a reference for evaluations of its quality and the clinical use.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Análise de Componente Principal , Quimiometria/métodos , Medicamentos de Ervas Chinesas/química , Geografia , Algoritmos , China
18.
PLoS One ; 19(5): e0287088, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38771771

RESUMO

A variety of costly research-grade imaging devices are available for the detection of spectroscopic features. Here we present an affordable, open-source and versatile device, suitable for a range of applications. We provide the files to print the imaging chamber with commonly available 3D printers and instructions to assemble it with easily available hardware. The imager is suitable for rapid sample screening in research, as well as for educational purposes. We provide details and results for an already proven set-up which suits the needs of a research group and students interested in UV-induced near-infrared fluorescence detection of microbial colonies grown on Petri dishes. The fluorescence signal confirms the presence of bacteriochlorophyll a in aerobic anoxygenic phototrophic bacteria (AAPB). The imager allows for the rapid detection and subsequent isolation of AAPB colonies on Petri dishes with diverse environmental samples. To this date, 15 devices have been build and more than 7000 Petri dishes have been analyzed for AAPB, leading to over 1000 new AAPB isolates. Parts can be modified depending on needs and budget. The latest version with automated switches and double band pass filters costs around 350€ in materials and resolves bacterial colonies with diameters of 0.5 mm and larger. The low cost and modular build allow for the integration in high school classes to educate students on light properties, fluorescence and microbiology. Computer-aided design of 3D-printed parts and programming of the employed Raspberry Pi computer could be incorporated in computer sciences classes. Students have been also inspired to do agar art with microbes. The device is currently used in seven different high schools in Finland. Additionally, a science education network of Finnish universities has incorporated it in its program for high school students. Video guides have been produced to facilitate easy operation and accessibility of the device.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Fluorescência , Processos Fototróficos , Imagem Óptica/métodos , Imagem Óptica/instrumentação
19.
Crit Care Explor ; 6(5): e1094, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38727717

RESUMO

OBJECTIVES: Near-infrared spectroscopy (NIRS) is a potentially valuable modality to monitor the adequacy of oxygen delivery to the brain and other tissues in critically ill patients, but little is known about the physiologic determinants of NIRS-derived tissue oxygen saturations. The purpose of this study was to assess the contribution of routinely measured physiologic parameters to tissue oxygen saturation measured by NIRS. DESIGN: An observational sub-study of patients enrolled in the Role of Active Deresuscitation After Resuscitation-2 (RADAR-2) randomized feasibility trial. SETTING: Two ICUs in the United Kingdom. PATIENTS: Patients were recruited for the RADAR-2 study, which compared a conservative approach to fluid therapy and deresuscitation with usual care. Those included in this sub-study underwent continuous NIRS monitoring of cerebral oxygen saturations (SctO2) and quadriceps muscle tissue saturations (SmtO2). INTERVENTION: Synchronized and continuous mean arterial pressure (MAP), heart rate (HR), and pulse oximetry (oxygen saturation, Spo2) measurements were recorded alongside NIRS data. Arterial Paco2, Pao2, and hemoglobin concentration were recorded 12 hourly. Linear mixed effect models were used to investigate the association between these physiologic variables and cerebral and muscle tissue oxygen saturations. MEASUREMENTS AND MAIN RESULTS: Sixty-six patients were included in the analysis. Linear mixed models demonstrated that Paco2, Spo2, MAP, and HR were weakly associated with SctO2 but only explained 7.1% of the total variation. Spo2 and MAP were associated with SmtO2, but together only explained 0.8% of its total variation. The remaining variability was predominantly accounted for by between-subject differences. CONCLUSIONS: Our findings demonstrated that only a small proportion of variability in NIRS-derived cerebral and tissue oximetry measurements could be explained by routinely measured physiologic variables. We conclude that for NIRS to be a useful monitoring modality in critical care, considerable further research is required to understand physiologic determinants and prognostic significance.


Assuntos
Estado Terminal , Oximetria , Saturação de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Feminino , Saturação de Oxigênio/fisiologia , Pessoa de Meia-Idade , Idoso , Oximetria/métodos , Monitorização Fisiológica/métodos , Encéfalo/metabolismo , Encéfalo/irrigação sanguínea , Reino Unido , Oxigênio/metabolismo , Oxigênio/sangue , Oxigênio/análise , Unidades de Terapia Intensiva , Músculo Quadríceps/metabolismo , Músculo Quadríceps/irrigação sanguínea
20.
Artigo em Inglês | MEDLINE | ID: mdl-38717876

RESUMO

Neurovascular coupling (NVC) provides important insights into the intricate activity of brain functioning and may aid in the early diagnosis of brain diseases. Emerging evidences have shown that NVC could be assessed by the coupling between electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS). However, this endeavor presents significant challenges due to the absence of standardized methodologies and reliable techniques for coupling analysis of these two modalities. In this study, we introduced a novel method, i.e., the collaborative multi-output variational Gaussian process convergent cross-mapping (CMVGP-CCM) approach to advance coupling analysis of EEG and fNIRS. To validate the robustness and reliability of the CMVGP-CCM method, we conducted extensive experiments using chaotic time series models with varying noise levels, sequence lengths, and causal driving strengths. In addition, we employed the CMVGP-CCM method to explore the NVC between EEG and fNIRS signals collected from 26 healthy participants using a working memory (WM) task. Results revealed a significant causal effect of EEG signals, particularly the delta, theta, and alpha frequency bands, on the fNIRS signals during WM. This influence was notably observed in the frontal lobe, and its strength exhibited a decline as cognitive demands increased. This study illuminates the complex connections between brain electrical activity and cerebral blood flow, offering new insights into the underlying NVC mechanisms of WM.


Assuntos
Algoritmos , Eletroencefalografia , Memória de Curto Prazo , Acoplamento Neurovascular , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Eletroencefalografia/métodos , Masculino , Feminino , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Adulto , Distribuição Normal , Acoplamento Neurovascular/fisiologia , Adulto Jovem , Memória de Curto Prazo/fisiologia , Voluntários Saudáveis , Reprodutibilidade dos Testes , Análise Multivariada , Lobo Frontal/fisiologia , Lobo Frontal/diagnóstico por imagem , Mapeamento Encefálico/métodos , Ritmo Teta/fisiologia , Encéfalo/fisiologia , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Dinâmica não Linear , Ritmo Delta/fisiologia , Ritmo alfa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA