Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22.888
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Neurosurg Rev ; 47(1): 215, 2024 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-38730072

RESUMO

BACKGROUND AND OBJECTIVES: Cerebral aneurysms in complex anatomical locations and intraoperative rupture can be challenging. Many methods to reduce blood flow can facilitate its exclusion from the circulation. This study evaluated the safety and efficacy of using adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping. METHODS: Databases (PubMed, Embase, and Web of Science) were systematically searched for studies documenting the use of adenosine, rapid ventricular pacing, and hypothermia in cerebral aneurysm clipping and were included in this single-arm meta-analysis. The primary outcome was 30-day mortality. Secondary outcomes included neurological outcomes by mRs and GOS, and cardiac outcomes. We evaluated the risk of bias using ROBIN-I, a tool developed by the Cochrane Collaboration. OpenMetaAnalyst version 2.0 was used for statistical analysis and I2 measured data heterogeneity. Heterogeneity was defined as an I2 > 50%. RESULTS: Our systematic search yielded 10,100 results. After the removal of duplicates and exclusion by title and abstract, 64 studies were considered for full review, of which 29 were included. The overall risk of bias was moderate. The pooled proportions of the adenosine analysis for the different outcomes were: For the primary outcome: 11,9%; for perioperative arrhythmia: 0,19%; for postoperative arrhythmia: 0,56%; for myocardial infarction incidence: 0,01%; for follow-up good recovery (mRs 0-2): 88%; and for neurological deficit:14.1%. In the rapid ventricular pacing analysis, incidences were as follows: peri operative arrhythmia: 0,64%; postoperative arrhythmia: 0,3%; myocardial infarction: 0%. In the hypothermia analysis, the pooled proportion of 30-day mortality was 11,6%. The incidence of post-op neurological deficits was 35,4% and good recovery under neurological analysis by GOS was present in 69.2%. CONCLUSION: The use of the three methods is safe and the related complications were very low. Further studies are necessary, especially with comparative analysis, for extended knowledge.


Assuntos
Adenosina , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/cirurgia , Adenosina/uso terapêutico , Hipotermia Induzida/métodos , Resultado do Tratamento , Procedimentos Neurocirúrgicos/métodos , Estimulação Cardíaca Artificial/métodos
2.
BMC Cardiovasc Disord ; 24(1): 246, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730404

RESUMO

BACKGROUND: Clinical outcomes after catheter ablation (CA) or pacemaker (PM) implantation for the tachycardia-bradycardia syndrome (TBS) has not been evaluated adequately. We tried to compare the efficacy and safety outcomes of CA and PM implantation as an initial treatment option for TBS in paroxysmal atrial fibrillation (AF) patients. METHODS: Sixty-eight patients with paroxysmal AF and TBS (mean 63.7 years, 63.2% male) were randomized, and received CA (n = 35) or PM (n = 33) as initial treatments. The primary outcomes were unexpected emergency room visits or hospitalizations attributed to cardiovascular causes. RESULTS: In the intention-to-treatment analysis, the rates of primary outcomes were not significantly different between the two groups at the 2-year follow-up (19.8% vs. 25.9%; hazard ratio (HR) 0.73, 95% confidence interval (CI) 0.25-2.20, P = 0.584), irrespective of whether the results were adjusted for age (HR 1.12, 95% CI 0.34-3.64, P = 0.852). The 2-year rate of recurrent AF was significantly lower in the CA group compared to the PM group (33.9% vs. 56.8%, P = 0.038). Four patients (11.4%) in the CA group finally received PMs after CA owing to recurrent syncope episodes. The rate of major or minor procedure related complications was not significantly different between the two groups. CONCLUSION: CA had a similar efficacy and safety profile with that of PM and a higher sinus rhythm maintenance rate. CA could be considered as a preferable initial treatment option over PM implantation in patients with paroxysmal AF and TBS. TRIAL REGISTRATION: KCT0000155.


Assuntos
Fibrilação Atrial , Bradicardia , Estimulação Cardíaca Artificial , Ablação por Cateter , Frequência Cardíaca , Marca-Passo Artificial , Recidiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fibrilação Atrial/cirurgia , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/fisiopatologia , Estimulação Cardíaca Artificial/efeitos adversos , Fatores de Tempo , Fatores de Risco , Síndrome , Taquicardia/fisiopatologia , Taquicardia/diagnóstico , Taquicardia/terapia , Taquicardia/cirurgia
3.
Circ Arrhythm Electrophysiol ; 17(5): e012513, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38690657

RESUMO

BACKGROUND: The anatomy of myocardial fibers around the right cardiac veins (RCVs) and their roles in accessory pathways (APs) are rarely reported. METHODS: Six RCV-APs were identified from 566 patients with right-sided APs. Mapping of retrograde atrial activation was performed using CARTO 3 system under orthodromic tachycardia or right ventricular pacing. Venography of RCVs was acquired at the earliest retrograde atrial activation. RESULTS: Patients enrolled had a median age of 30 (11-51) years, 5 of them were male. Venography of RCVs could be classified into 3 distinct patterns based on the identified ventricular branches, right marginal vein only (type I; n=3), both right marginal vein and anterior cardiac veins (type II; n=2), and anterior cardiac vein only (type III; n=1). Patients with type I venography had rS QRS pattern in lead V1, negative delta wave in lead III and negative or isoelectric delta wave in lead aVF. However, patients with type II and III venography had QS QRS patterns in lead V1 and variable patterns of delta wave in inferior leads. Earliest retrograde atrial activation was found at a median of 16.75 (14.60-20.00) mm away from the tricuspid annulus, all with A larger than V. At the earliest retrograde atrial activation, far-field ventricular electrogram was found 30 ms later than QRS onset in 1 patient under sinus rhythm. AP conduction was eliminated by mechanical pressure in 2 and by radiofrequency ablation in 4 at the ostium of the veins colocalizing with the earliest retrograde activation of the right atrium. No recurrence was observed during 36 (10-60) months follow-up. CONCLUSIONS: The RCV-AP is a rare form of right-sided APs characterized by atrial insertions distant from the annulus. ECG-speculated ventricular insertion sites conformed to the location of identified RCVs.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Flebografia , Humanos , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Feixe Acessório Atrioventricular/fisiopatologia , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Adulto Jovem , Criança , Técnicas Eletrofisiológicas Cardíacas , Vasos Coronários/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Potenciais de Ação , Frequência Cardíaca , Estimulação Cardíaca Artificial
4.
Card Electrophysiol Clin ; 16(2): 149-155, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749634

RESUMO

Leadless pacemaker systems (LPs) were developed as an alternative to traditional transvenous permanent pacemakers (TV-PPM) due to increasing rates of device and procedural related complications, leading to a high-cost burden to our health-care system. LPs were initially indicated for single-chamber ventricular pacing; however, recent developments have allowed for dual-chamber pacing too. These systems have demonstrated highly successful implant rates with stable pacing performance. This article describes the retrieval techniques of the Micra LPs and ways to mitigate challenges encountered during the retrieval process.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/métodos
5.
Ann Noninvasive Electrocardiol ; 29(3): e13113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38563226

RESUMO

The anatomy of the His-Purkinje system has been studied, yet there remains a knowledge gap regarding the impact of His bundle pacing and its electrocardiographic implications. This case report highlights the presence of His-Purkinje system pathology without apparent clues on the surface electrocardiogram (EKG). By observing identical QRS morphology with varying HV intervals resulting from different pacing outputs, we demonstrate the presence of an electrical propagation block within the His bundle.


Assuntos
Fascículo Atrioventricular , Ramos Subendocárdicos , Humanos , Eletrocardiografia/métodos , Estimulação Cardíaca Artificial/métodos
7.
JACC Cardiovasc Interv ; 17(8): 1020-1028, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658116

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective and safe therapy for severe aortic stenosis. Rapid or fast pacing is required for implantation, which can be performed via a pre-existing cardiac implantable electric device (CIED). However, safety data on CIEDs for pacing in TAVR are missing. OBJECTIVES: The aim of this study was to elucidate procedural safety and feasibility of internal pacing with a CIED in TAVR. METHODS: Patients undergoing TAVR with a CIED were included in this analysis. Baseline characteristics, procedural details, and complications according to Valve Academic Research Consortium 3 (VARC-3) criteria after TAVR were compared between both groups. RESULTS: A total of 486 patients were included. Pacing was performed using a CIED in 150 patients and a transient pacemaker in 336 patients. No differences in technical success according to VARC-3 criteria or procedure duration occurred between the groups. The usage of transient pacers for pacing was associated with a significantly higher bleeding rate (bleeding type ≥2 according to VARC-3-criteria; 2.0% vs 13.1%; P < 0.01). Furthermore, impairment of the CIED appeared in 2.3% of patients after TAVR only in the group in which pacing was performed by a transient pacer, leading to surgical revision of the CIED in 1.3% of all patients when transient pacemakers were used. CONCLUSIONS: Internal pacing using a CIED is safe and feasible without differences of procedural time and technical success and might reduce bleeding rates. Furthermore, pacing using a CIED circumvents the risk of lead dislocation. Our data provide an urgent call for the use of a CIED for pacing during a TAVR procedure in general.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Hospitais com Alto Volume de Atendimentos , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Resultado do Tratamento , Fatores de Tempo , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Estudos Retrospectivos , Índice de Gravidade de Doença , Medição de Risco
11.
Tex Heart Inst J ; 51(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38564374

RESUMO

This report discusses a case of transient 2:1 atrioventricular block with conduction system pacing 4 hours after leadless right ventricular pacemaker implantation in a 19-year-old patient with a history of cardioinhibitory syncope and asystole cardiac arrest but without preexisting atrioventricular block. The atrioventricular block was resolved spontaneously. Pacing morphology was suggestive of right bundle branch pacing. Neither 2:1 atrioventricular block nor conduction system pacing has previously been a reported outcome of right ventricular leadless pacemaker implantation. The report demonstrates that conduction system pacing with leadless devices is achievable. Further study of techniques, limitations, and complications related to intentional right ventricular leadless conduction system pacing is warranted.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Adulto Jovem , Adulto , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial/efeitos adversos , Sistema de Condução Cardíaco , Ventrículos do Coração , Resultado do Tratamento
12.
Tex Heart Inst J ; 51(1)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38680081

RESUMO

Transcatheter aortic valve replacement is quickly becoming the standard of care for patients with severe aortic stenosis thanks to its minimally invasive nature and favorable outcomes. Recently, left ventricular pacing has been proposed as a safer alternative to traditional right heart pacing, which could simplify the transcatheter aortic valve replacement procedure overall, although procedural complications may still occur. This report describes a rare case of left ventricular pacing wire-induced acute severe mitral valve regurgitation during transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Doença Aguda , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/métodos , Masculino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia , Marca-Passo Artificial/efeitos adversos , Feminino , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem
14.
J Am Heart Assoc ; 13(9): e032777, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639357

RESUMO

BACKGROUND: A delayed and recurrent complete atrioventricular block (CAVB) is a life-threatening complication of transcatheter aortic valve replacement (TAVR). Post-TAVR evaluation may be important in predicting delayed and recurrent CAVB requiring permanent pacemaker implantation (PPI). The impact of new-onset right bundle-branch block (RBBB) after TAVR on PPI remains unknown. METHODS AND RESULTS: In total, 407 patients with aortic stenosis who underwent TAVR were included in this analysis. Intraprocedural CAVB was defined as CAVB that occurred during TAVR. A 12-lead ECG was evaluated at baseline, immediately after TAVR, on postoperative days 1 and 5, and according to the need to identify new-onset bundle-branch block (BBB) and CAVB after TAVR. Forty patients (9.8%) required PPI, 17 patients (4.2%) had persistent intraprocedural CAVB, and 23 (5.7%) had delayed or recurrent CAVB after TAVR. The rates of no new-onset BBB, new-onset left BBB, and new-onset RBBB were 65.1%, 26.8%, and 4.7%, respectively. Compared with patients without new-onset BBB and those with new-onset left BBB, the rate of PPI was higher in patients with new-onset RBBB (3.4% versus 5.6% versus 44.4%, P<0.0001). On post-TAVR evaluation in patients without persistent intraprocedural CAVB, the multivariate logistic regression analysis showed that new-onset RBBB was a statistically significant predictor of PPI compared with no new-onset BBB (odds ratio [OR], 18.0 [95% CI, 5.94-54.4]) in addition to the use of a self-expanding valve (OR, 2.97 [95% CI, 1.09-8.10]). CONCLUSIONS: Patients with new-onset RBBB after TAVR are at high risk for PPI.


Assuntos
Estenose da Valva Aórtica , Bloqueio de Ramo , Estimulação Cardíaca Artificial , Eletrocardiografia , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Estenose da Valva Aórtica/cirurgia , Idoso de 80 Anos ou mais , Idoso , Estimulação Cardíaca Artificial/efeitos adversos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Complicações Pós-Operatórias/diagnóstico , Recidiva
15.
J Am Heart Assoc ; 13(9): e034004, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639381

RESUMO

BACKGROUND: An epicardial connection (EC) through the intercaval bundle (EC-ICB) between the right pulmonary vein (RPV) and right atrium (RA) is one of the reasons for the need for carina ablation for PV isolation and may reduce the acute and chronic success of PV isolation. We evaluated the intra-atrial activation sequence during RPV pacing after failure of ipsilateral RPV isolation and sought to identify specific conduction patterns in the presence of EC-ICB. METHODS AND RESULTS: This study included 223 consecutive patients who underwent initial catheter ablation of atrial fibrillation. If the RPV was not isolated using circumferential ablation or reconnected during the waiting period, an exit map was created during mid-RPV carina pacing. If the earliest site on the exit map was the RA, the patient was classified into the EC-ICB group. The exit map, intra-atrial activation sequence, and RPV-high RA time were evaluated. First-pass isolation of the RPV was not achieved in 36 patients (16.1%), and 22 patients (9.9%) showed reconnection. Twelve and 28 patients were classified into the EC-ICB and non-EC-ICB groups, respectively, after excluding those with multiple ablation lesion sets or incomplete mapping. The intra-atrial activation sequence showed different patterns between the 2 groups. The RPV-high RA time was significantly shorter in the EC-ICB than in the non-EC-ICB group (69.2±15.2 versus 148.6±51.2 ms; P<0.001), and RPV-high RA time<89.0 ms was highly predictive of the existence of an EC-ICB (sensitivity, 91.7%; specificity, 89.3%). CONCLUSIONS: An EC-ICB can be effectively detected by intra-atrial sequencing during RPV pacing, and an RPV-high RA time of <89.0 ms was highly predictive.


Assuntos
Fibrilação Atrial , Estimulação Cardíaca Artificial , Ablação por Cateter , Átrios do Coração , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Feminino , Masculino , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Estimulação Cardíaca Artificial/métodos , Idoso , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Pericárdio/cirurgia , Pericárdio/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca/fisiologia
18.
Medicina (Kaunas) ; 60(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38541230

RESUMO

Background and Objectives: Atrioventricular (AV) dyssynchrony as well as atrial and ventricular pacing affect left atrial (LA) function. We conducted a study evaluating the effect of atrial and ventricular pacing on LA morphological and functional changes after dual-chamber pacemaker implantation. Materials and Methods: The study prospectively enrolled 121 subjects who had a dual-chamber pacemaker implanted due to sinus node disease (SND) or atrioventricular block (AVB). Subjects were divided into three groups based on indication and pacemaker programming: (1) SND DDDR 60; (2) AVB DDD 60 and (3) AVB DDD 40. Subjects were invited to one- and three-month follow-up visits. Three subsets based on pacing burden were analyzed: (1) high atrial (A) low ventricular (V); (2) high A, high V and (3) low A, high V. LA function was assessed from volumetric parameters and measured strains from echocardiography. Results: The high A, low V group consisted of 38 subjects; while high A, high V had 26 and low A, high V had 23. A significant decrease in reservoir and contractile LA strain parameters were only observed in the high A, low V pacing group after three months (reservoir 25.9 ± 10.3% vs. 21.1 ± 9.9%, p = 0.003, contractile -14.0 ± 9.0% vs. -11.1 ± 7.8, p = 0.018). While the re-established atrioventricular synchrony in the low A, high V group maintained reservoir LA strain at the baseline level after three months (21.4 ± 10.4% vs. 22.5 ± 10.4%, p = 0.975); in the high A, high V group, a further trend to decrease was noted (20.3 ± 8.9% vs. 18.7 ± 8.3%, p = 0.231). Conclusions: High atrial pacing burden independently of atrioventricular dyssynchrony and ventricular pacing impairs LA functional and morphological parameters. Changes appear soon after pacemaker implantation and are maintained.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Átrios do Coração , Síndrome do Nó Sinusal/terapia , Bloqueio Atrioventricular/terapia
19.
Acta Biomater ; 178: 330-339, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38432350

RESUMO

Cardiac pacing with temporary epicardial pacing wires (TEPW) is used to treat rhythm disturbances after cardiac surgery. Occasionally, TEPW cannot be mechanically extracted and remain in the thorax, where they may rarely cause serious complications like migration and infection. We aim to develop bioresorbable TEPW that will dissolve over time even if postoperative removal is unsuccessful. In the present study, we demonstrate a completely bioresorbable design using molybdenum (Mo) as electric conductor and the resorbable polymers poly(D, L-lactic-co-glycolic acid) (PLGA) and polycaprolactone (PCL) for electrically insulating double-coating. We compared the pacing properties of these Mo TEPW demonstrators to conventional steel TEPW in Langendorff-perfused rat hearts and observed similar functionality. In vitro, static immersion tests in simulated body fluid for up to 28 days elucidated the degradation behaviour of uncoated Mo strands and the influence of polymer coating thereon. Degradation was considerably reduced in double-coated Mo TEPW compared to the uncoated and the PLGA-coated condition. Furthermore, we confirmed good biocompatibility of Mo degradation products in the form of low cytotoxicity in cell cultures of human cardiomyocytes and cardiac fibroblasts. STATEMENT OF SIGNIFICANCE: Temporary pacing wires are routinely implanted on the heart surface to treat rhythm disturbances in the days following cardiac surgery. Subsequently, these wires are to be removed. When removal attempts are unsuccessful, wires are cut at skin level and the remainders are left inside the chest. Retained fragments may migrate within the body or become a centre of infection. These complications may be prevented using resorbable pacing wires. We manufactured completely resorbable temporary pacing wires using molybdenum as electrical conductor and assessed their function, degradation and biological compatibility. Our study represents an important step in the development of a safer approach to the treatment of rhythm disturbances after cardiac surgery.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Animais , Ratos , Molibdênio/farmacologia , Implantes Absorvíveis , Pericárdio
20.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA