Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.642
Filtrar
1.
Food Res Int ; 183: 114240, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38760119

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic organic pollutants found in various environments, notably aquatic ecosystems and the food chain, posing significant health risks. Traditional methods for detecting PAHs in food involve complex processes and considerable reagent usage, raising environmental concerns. This study explores eco-friendly approaches suing solid phases derived from natural sources in matrix solid phase dispersion. We aimed to develop, optimize, and validate a sample preparation technique for seafood, employing natural materials for PAH analysis. Ten natural phases were compared with a commercial reference phase. The methodology involved matrix solid phase dispersion and pressurized liquid extraction, followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Three solid phases (perlite, sweet manioc starch, and barley) showed superior performance in LC-MS/MS and were further evaluated with gas chromatography-tandem mass spectrometry (GC-MS/MS), confirming perlite as the most effective phase. Validation followed Brazilian regulatory guidelines and European Community Regulation 2021/808/EC. The resulting method offered advantages in cost-effectiveness, reduced environmental impact, cleaner extracts, and enhanced analytical performance compared to the reference solid phase and LC-MS/MS. Proficiency analysis confirmed method reliability, with over 50% alignment with green analytical chemistry principles. In conclusion, this study developed an environmentally sustainable sample preparation technique for seafood analysis using natural solid phases, particularly perlite, for PAH determination.


Assuntos
Contaminação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Hidrocarbonetos Policíclicos Aromáticos , Alimentos Marinhos , Espectrometria de Massas em Tandem , Hidrocarbonetos Policíclicos Aromáticos/análise , Alimentos Marinhos/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Contaminação de Alimentos/análise , Extração em Fase Sólida/métodos , Reprodutibilidade dos Testes , Brasil , Química Verde/métodos
2.
Food Res Int ; 187: 114359, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38763643

RESUMO

Chinese Xiaokeng green tea (XKGT) possesses elegant and fascinating aroma characteristics, but its key odorants are still unknown. In this study, 124 volatile compounds in the XKGT infusion were identified by headspace-solid phase microextraction (HS-SPME), stir bar sorptive extraction (SBSE), and solvent extraction-solid phase extraction (SE-SPE) combined with gas chromatography-mass spectrometry (GC-MS). Comparing these three pretreatments, we found HS-SPME was more efficient for headspace compounds while SE-SPE was more efficient for volatiles with higher boiling points. Furthermore, SBSE showed more sensitive to capture ketones then was effective to the application of pretreatment of aroma analysis in green tea. The aroma intensities (AIs) were further identified by gas chromatography-olfactometry (GC-O). According to the AI and relative odor activity value (rOAV), 27 compounds were identified as aroma-active compounds. Quantitative descriptive analysis (QDA) showed that the characteristic aroma attributes of XKGT were chestnut-like, corn-like, fresh, and so on. The results of network analysis showed that (E, Z)-2,6-nonadienal, nonanal, octanal and nerolidol were responsible for the fresh aroma. Similarly, dimethyl sulfide, (E, E)-2,4-heptadienal, (E)-2-octenal and ß-cyclocitral contributed to the corn-like aroma. Furthermore, indole was responsible for the chestnut-like and soybean-like aroma. This study contributes to a better understanding of the molecular mechanism of the aroma characteristics of XKGT.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Odorantes , Olfatometria , Microextração em Fase Sólida , Chá , Compostos Orgânicos Voláteis , Odorantes/análise , Chá/química , Compostos Orgânicos Voláteis/análise , Microextração em Fase Sólida/métodos , Humanos , Camellia sinensis/química , Extração em Fase Sólida/métodos
3.
J Sep Sci ; 47(9-10): e2300925, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38726740

RESUMO

Deep eutectic solvents (DESs), as a new type of eco-friendly solvent, have attracted increasing attention on the extraction and separation of flavonoid compounds from various samples, owing to their excellent properties such as biodegradability and ease of handling with very low toxicity. This article provides a status review of the applications of DESs in the extraction of flavonoids, including the introduction of flavonoid compounds, the properties and superiority of DESs, and extraction methods (ultrasonic-assisted extraction, heating reflux extraction, matrix solid-phase dispersion, and solid-phase extraction). Finally, prospects and challenges in the application of DESs on extraction and separation are extensively elucidated and critically reviewed.


Assuntos
Solventes Eutéticos Profundos , Flavonoides , Extração em Fase Sólida , Flavonoides/isolamento & purificação , Flavonoides/química , Solventes Eutéticos Profundos/química , Solventes/química
4.
Molecules ; 29(9)2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38731551

RESUMO

The aim of this study is to solve the problems of the complicated pretreatment and high analytical cost in the detection technology of trace drugs and their metabolites in municipal wastewater. A high-performance magnetic sorbent was fsynthesized for the enrichment of trace drugs and their metabolites in wastewater to develop a magnetic solid-phase extraction pretreatment combined with the acoustic ejection mass spectrometry (AEMS) analytical method. The magnetic nanospheres were successfully prepared by magnetic nanoparticles modified with divinylbenzene and vinylpyrrolidone. The results showed that the linear dynamic range of 17 drugs was 1-500 ng/mL, the recovery was 44-100%, the matrix effect was more than 51%, the quantification limit was 1-2 ng/mL, and the MS measurement was fast. It can be seen that the developed magnetic solid-phase extraction (MSPE) method is a good solution to the problems of the complicated pretreatment and analytical cost in the analysis of drugs in wastewater. The developed magnetic material and acoustic excitation pretreatment coupled with mass spectrometry analysis method can realize the low-cost, efficient enrichment, and fast analysis of different kinds of drug molecules in urban sewage.


Assuntos
Drogas Ilícitas , Espectrometria de Massas , Esgotos , Extração em Fase Sólida , Esgotos/análise , Esgotos/química , Extração em Fase Sólida/métodos , Espectrometria de Massas/métodos , Drogas Ilícitas/análise , Poluentes Químicos da Água/análise , Águas Residuárias/análise , Águas Residuárias/química , Nanopartículas de Magnetita/química
5.
Molecules ; 29(9)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38731605

RESUMO

The aim of this study is to develop a rapid and accurate method for simultaneous analysis of multi-residue pesticides and conduct pesticide monitoring in agricultural products produced by the production and distribution stage in Korea. The representative agricultural products were selected as brown rice, soybean, potato, mandarin, and green pepper and developed using gas chromatography with tandem mass (GC-MS/MS) for the analysis of 272 pesticide residues. The experimental samples were extracted by the QuEChERS-EN method and then cleaned up by using d-SPE, including MgSO4 and primary secondary amine (PSA) sorbents. The established method was validated in accordance with Codex CAC-GL/40, and the limit of quantitation (LOQ) was determined to be 0.01 mg/kg. A total of 243 pesticides satisfied the guidelines in five samples at three levels with values of 60 to 120% (recovery) and ≤45% (coefficient of variation, CV). The remaining 29 pesticides did not satisfy the guidelines, and these pesticides are expected to be used as a screening method for the routine inspection of agricultural products. As a result of analyzing 223 agricultural products in South Korea by applying the simultaneous analysis method, none of the detected levels in the samples exceeded the standard values based on maximum residue limits (MRLs). The developed method in this study will be used to inspect residual pesticides in agricultural products, and it is anticipated to contribute to the distribution of safe agricultural products to consumers.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Resíduos de Praguicidas , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Resíduos de Praguicidas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Praguicidas/análise , Produtos Agrícolas/química , República da Coreia , Contaminação de Alimentos/análise , Limite de Detecção , Extração em Fase Sólida/métodos
6.
J Chromatogr A ; 1725: 464943, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38691924

RESUMO

In this study, we proposed a novel method utilizing polyethyleneimine (PEI)-modified halloysite nanotubes (HNTs)-based hybrid silica monolithic spin tip to analyze hydrophilic ß-lactam antibiotics and ß-lactamases inhibitors in whole blood samples for the first time. HNTs were incorporated directly into the hybrid silica monolith via a sol-gel method, which improved the hydrophilicity of the matrix. The as-prepared monolith was further modified with PEI by glutaraldehyde coupling reaction. It was found that the PEI-modified HNTs-based hybrid silica monolith enabled a large adsorption capacity of cefoperazone at 35.7 mg g-1. The monolithic spin tip-based purification method greatly reduced the matrix effect of whole blood samples and had a detection limit as low as 0.1 - 0.2 ng mL-1. In addition, the spiked recoveries of sulbactam, cefuroxime, and cefoperazone in blank whole blood were in the range of 89.3-105.4 % for intra-day and 90.6-103.5 % for inter-day, with low relative standard deviations of 1.3-7.2 % and 4.9-10.5 %, respectively. This study introduces a new strategy for preparing nanoparticles incorporated in a hybrid silica monolith with a high adsorption capacity. Moreover, it offers a valuable tool to monitor sulbactam, cefoperazone, and cefuroxime in whole blood from pregnant women with the final aim of guiding their administration.


Assuntos
Cefoperazona , Cefuroxima , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Nanotubos , Dióxido de Silício , Extração em Fase Sólida , Sulbactam , Cefoperazona/sangue , Cefoperazona/química , Humanos , Sulbactam/sangue , Sulbactam/química , Extração em Fase Sólida/métodos , Dióxido de Silício/química , Nanotubos/química , Cefuroxima/sangue , Cefuroxima/química , Argila/química , Adsorção , Antibacterianos/sangue , Antibacterianos/química , Polietilenoimina/química , Cromatografia Líquida de Alta Pressão/métodos , Reprodutibilidade dos Testes
7.
J Chromatogr A ; 1725: 464957, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38703458

RESUMO

This study focuses on the purification and detection of glufosinate (GLUF) and its metabolites N-acetyl GLUF and MPP in plasma samples. A Dikma Polyamino HILIC column was used for the effective retention and separation of GLUF and its metabolites, and the innovative addition of a low concentration of ammonium fluoride solution to the mobile phase effectively improved the detection sensitivity of the target analytes. Monodisperse core-shell weak cation exchange (WCX)/C18 bifunctional magnetic polymer composites (Fe3O4@WCX/C18) were prepared in a controllable manner, and their morphology and composition were fully characterized. The Fe3O4@WCX/C18 microspheres were used as a magnetic solid-phase extraction (MSPE) adsorbent for the sample purification and detection of GLUF and its metabolites in plasma samples combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The purification conditions of Fe3O4@WCX/C18 microspheres for GLUF and its metabolites in spiked plasma samples were optimized to achieve the best MSPE efficiency. The purification mechanisms of the target analytes in plasma samples include electrostatic attraction and hydrophobic interactions. Furthermore, the effect of the molar ratio of the two functional monomers 4-VBA and 1-octadecene in the adsorbent was optimized and it shows that the bifunctional components WCX/C18 have a synergistic effect on the determination of GLUF and its metabolites in plasma samples. In addition, the present study compared the purification performance of the Fe3O4@WCX/C18 microsphere-based MSPE method with that of the commercial Oasis WCX SPE method, and the results showed that the Fe3O4@WCX/C18 microsphere-based MSPE method established in this work had a stronger ability to remove matrix interferences. Under optimal purification conditions, the recoveries of GLUF and its metabolites in plasma were 87.6-111 % with relative standard deviations (RSDs) ranging from 0.2 % to 4.8 %. The limits of detection (LODs, S/N≥3) and limits of quantification (LOQs, S/N≥10) were 0.10-0.18 µg/L and 0.30-0.54 µg/L, respectively. The MSPE-LC-MS/MS method developed in this study is fast, simple, accurate and sensitive and can be used to confirm GLUF intoxication based not only on the detection of the GLUF prototype but also on the detection of its two metabolites.


Assuntos
Aminobutiratos , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Aminobutiratos/sangue , Aminobutiratos/química , Cromatografia Líquida/métodos , Limite de Detecção , Polímeros/química , Animais , Microesferas , Adsorção , Ratos , Cromatografia por Troca Iônica/métodos
8.
Mikrochim Acta ; 191(6): 297, 2024 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-38709347

RESUMO

A new detection platform based on a hydroxylated covalent organic framework (COF) integrated with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was constructed and used for detecting adrenergic receptor agonists (ARAs) residues in milk. The hydroxylated COF was prepared by polymerization of tris(4-aminophenyl)amine and 1,3,5-tris(4-formyl-3-hydroxyphenyl)benzene and applied to solid-phase extraction (SPE) of ARAs. This hydroxylated COF was featured with hierarchical flower-like morphology, easy preparation, and copious active adsorption sites. The adsorption model fittings and molecular simulation were applied to explore the potential adsorption mechanism. This detection platform was suitable for detecting four α2- and five ß2-ARAs residues in milk. The linear ranges of the ARAs were from 0.25 to 50 µg·kg-1; the intra-day and the inter-day repeatability were in the range 2.9-7.9% and 2.0-10.1%, respectively. This work demonstrates this hydroxylated COF has great potential as SPE cartridge packing, and provides a new way to determine ARAs residues in milk.


Assuntos
Leite , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Extração em Fase Sólida/métodos , Leite/química , Animais , Espectrometria de Massas em Tandem/métodos , Hidroxilação , Estruturas Metalorgânicas/química , Adsorção , Agonistas Adrenérgicos/química , Agonistas Adrenérgicos/análise , Limite de Detecção , Bovinos
9.
Anal Methods ; 16(19): 3142-3153, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38713147

RESUMO

We develop and validate a method for the rapid determination and identification of 20 ß-lactamase antibiotics traces in goat's milk by combining the solid phase extraction technology with ultra-high performance liquid chromatography-tandem mass spectrometry. Goat milk samples were extracted with acetonitrile twice. The supernatant was then extracted and cleaned by solid-phase extraction using divinylbenzene and N-vinylpyrrolidone copolymer. The method was validated, with limits of quantification (LOQs) of 0.3 µg kg-1, specificities of 1/3 LOQ, linearities (R2) > 0.99, recoveries of 80-110%, repeatabilities <10.0%, and intermediate precisions <10.0%. The developed method was suitable for the routine analysis of ß-lactamase antibiotics residues in goat's milk and was used to test 76 goat milk samples produced in China.


Assuntos
Antibacterianos , Cabras , Leite , Extração em Fase Sólida , Espectrometria de Massas em Tandem , beta-Lactamases , Animais , Extração em Fase Sólida/métodos , Leite/química , Espectrometria de Massas em Tandem/métodos , Antibacterianos/análise , Cromatografia Líquida de Alta Pressão/métodos , Limite de Detecção , Reprodutibilidade dos Testes , Resíduos de Drogas/análise , Contaminação de Alimentos/análise , Espectrometria de Massa com Cromatografia Líquida
10.
J Pharm Biomed Anal ; 245: 116161, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38714135

RESUMO

In this study, Fe3O4@ZnCr-layered double hydroxide/zeolitic imidazolate frameworks-8 (MLDH/ZIF-8) magnetically functionalized composites were synthesized by co-precipitation and in situ growth based on the advantages of LDHs and ZIF-8 using Fe3O4 nanoparticles as a magnetic substrate to obtain adsorbents with excellent performance. Moreover, the composite was used for the efficient enrichment of flavonoids in Chinese herbal medicines. The internal structures and surface properties were characterized by SEM, Fourier transform infrared spectroscopy, X-ray diffraction and so on. MLDH/ZIF-8 exhibited a large specific surface area and good paramagnetic properties. The MLDH/ZIF-8 magnetic composite was used as a magnetic solid-phase extraction (MSPE) adsorbent, and a MLDH/ZIF-8 MSPE-pressurized capillary electrochromatography coupling method was developed for the separation and detection of flavonoids (luteolin, kaempferol and apigenin) in a sample of the Chinese herb Ohwia caudata (Thunberg) H. Ohashi. The relevant parameters affecting the extraction efficiency were optimized to determine the ideal conditions for MSPE. 5 mg of adsorbent in sample solution at pH 6, vortex extraction for 5 min, elution with 1.5 mL of ethyl acetate for 15 min. The method showed good linearity in the concentration range of 3-50 µg mL-1 with correlation coefficients of 0.9934-0.9981, and displayed a relatively LODs of 0.07-0.09 µg mL-1. The spiked recoveries of all analytes ranged from 84.5% to 122.0% with RSDs (n=3) between 4.5% and 7.7%. This method is straightforward and efficient, with promising potential in the separation and analysis of active ingredients in various Chinese herbal medicines.


Assuntos
Medicamentos de Ervas Chinesas , Flavonoides , Hidróxidos , Extração em Fase Sólida , Flavonoides/isolamento & purificação , Flavonoides/análise , Flavonoides/química , Extração em Fase Sólida/métodos , Hidróxidos/química , Medicamentos de Ervas Chinesas/química , Adsorção , Nanopartículas de Magnetita/química , Estruturas Metalorgânicas/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
11.
J Chromatogr A ; 1726: 464965, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38733925

RESUMO

Aristolochic acids (AAs) naturally occurring in the herbal genus Aristolochia are associated with a high risk of kidney failure, multiple tumors and cancers. However, approaches with high selectivity and rapidity for measuring AAs in biological samples are still inadequate. Inspired by the mechanism of AAs-induced nephrotoxicity, we designed a hybrid magnetic polymer-porous agarose (denoted as MNs@SiO2M@DNV-A), mimicking the effect of basic and aromatic residues of organic anion transporter 1 (OAT1) for efficient enriching aristolochic acid I (AA I) and aristolochic acid II (AA II) in the plasma. The monomers of vinylbenzyl trimethylammonium chloride (VBTAC), N-vinyl-2-pyrrolidinone (NVP) and divinylbenzene (DVB) were employed to construct the polymer layer, which provided a selective adsorption for AAs by multiple interactions. The porous agarose shell contributed to remove interfering proteins in the plasma samples. A magnetic solid-phase extraction (MSPE) based on the proposed composite enhanced the selectivity toward AA I and AA II in the plasma samples. In combination of HPLC analysis, the proposed method was proved to be applicable to fast and specific quantification of AAs in blood samples, which was characterized by a good linearity, high sensitivity, acceptable recovery, excellent repeatability and satisfactory reusability.


Assuntos
Ácidos Aristolóquicos , Compostos de Amônio Quaternário , Sefarose , Extração em Fase Sólida , Ácidos Aristolóquicos/química , Ácidos Aristolóquicos/isolamento & purificação , Ácidos Aristolóquicos/sangue , Sefarose/química , Extração em Fase Sólida/métodos , Compostos de Amônio Quaternário/química , Cromatografia Líquida de Alta Pressão/métodos , Porosidade , Limite de Detecção , Animais , Humanos , Polímeros/química , Adsorção , Reprodutibilidade dos Testes
12.
Chemosphere ; 358: 142201, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38692367

RESUMO

Thallium (Tl) is a potential toxicity element that poses significant ecological and environmental risks. Recently, a substantial amount of Tl has been released into the environment through natural and human activities, which attracts increasing attention. The determination of this hazardous and trace element is crucial for controlling its pollution. This article summarizes the advancement and progress in optimizing Tl detection techniques, including atomic absorption spectroscopy (AAS), voltammetry, inductively coupled plasma (ICP)-based methods, spectrophotometry, and X-ray-based methods. Additionally, it introduces sampling and pretreatment methods such as diffusive gradients in thin films (DGT), liquid-liquid extraction, solid phase extraction, and cloud point extraction. Among these techniques, ICP-mass spectrometry (MS) is the preferred choice for Tl detection due to its high precision in determining Tl as well as its species and isotopic composition. Meanwhile, some new materials and agents are employed in detection. The application of novel work electrode materials and chromogenic agents is discussed. Emphasis is placed on reducing solvent consumption and utilizing pretreatment techniques such as ultrasound-assisted processes and functionalized magnetic particles. Most detection is performed in aqueous matrices, while X-ray-based methods applied to solid phases are summarized which provide non-destructive analysis. This work improves the understanding of Tl determination technology while serving as a valuable resource for researchers seeking appropriate analytical techniques.


Assuntos
Monitoramento Ambiental , Tálio , Tálio/análise , Monitoramento Ambiental/métodos , Poluentes Ambientais/análise , Espectrofotometria Atômica , Extração em Fase Sólida/métodos , Espectrometria de Massas/métodos , Extração Líquido-Líquido/métodos
13.
Chemosphere ; 358: 142227, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38704046

RESUMO

The widespread detection of perfluorooctanoic acid (PFOA) in the environment has raised significant concerns. The standard PFOA analytical method relies on expensive solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) instruments, making routine use prohibitive. We herein proposed a cost-effective yet novel enrichment method for determining PFOA at ng L-1 level. This method entailed a two-step sample preparation process: firstly, PFOA was extracted and enriched using a forward-extraction under acidic conditions, followed by a backward-extraction and enrichment step utilizing alkaline water. The enriched samples were subsequently subjected to a common ion chromatography (IC). Results reveal that maintaining a forward-extraction pH below its pKa value (2.8) is essential, as protonated PFOA proves effective in enhancing the enrichment factor (EF). The challenge lied in driving PFOA from forward-extractant to aqueous backward-extractant due to the decreased hydrophobicity of deprotonated PFOA (log Kow2 = 1.0). In addition, we found that evaporating forward-extractant with alkaline backward-extractant (containing 5% methanol) reduced potential analytical uncertainties associated with PFOA evaporation and sorption. Under optimal conditions, the method achieved a detection limit of 9.2 ng L-1 and an impressive EF value of 719. Comparison with SPE-LC-MS/MS confirmed the proposed method as a promising alternative for PFOA determination. Although initially targeted for PFOA, the novel methodology is likely applicable to preconcentration of other poly-fluoroalkyl substances.


Assuntos
Caprilatos , Fluorocarbonos , Extração Líquido-Líquido , Espectrometria de Massas em Tandem , Poluentes Químicos da Água , Caprilatos/análise , Caprilatos/química , Fluorocarbonos/análise , Fluorocarbonos/isolamento & purificação , Fluorocarbonos/química , Poluentes Químicos da Água/análise , Espectrometria de Massas em Tandem/métodos , Extração Líquido-Líquido/métodos , Cromatografia Líquida/métodos , Extração em Fase Sólida/métodos , Água/química , Monitoramento Ambiental/métodos
14.
Environ Sci Technol ; 58(19): 8518-8530, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38693060

RESUMO

Wastewater-based epidemiology (WBE) has been widely implemented around the world as a complementary tool to conventional surveillance techniques to inform and improve public health responses. Currently, wastewater surveillance programs in the U.S. are evaluating integrated approaches to address public health challenges across multiple domains, including substance abuse. In this work, we demonstrated the potential of online solid-phase extraction coupled with liquid chromatography-high-resolution mass spectrometry to support targeted quantification and nontargeted analysis of psychoactive and lifestyle substances as a step toward understanding the operational feasibility of a statewide wastewater surveillance program for substance use assessment in New York. Target screening confirmed 39 substances in influent samples collected from 10 wastewater treatment plants with varying sewershed characteristics and is anticipated to meet the throughput demands as the statewide program scales up to full capacity. Nontarget screening prioritized additional compounds for identification at three confidence levels, including psychoactive substances, such as opioid analgesics, phenethylamines, and cathinone derivatives. Consumption rates of 12 target substances detected in over 80% of wastewater samples were similar to those reported by previous U.S.-based WBE studies despite the uncertainty associated with back-calculations. For selected substances, the relative bias in consumption estimates was sensitive to variations in monitoring frequency, and factors beyond human excretion (e.g., as indicated by the parent-to-metabolite ratios) might also contribute to their prevalence at the sewershed scale. Overall, our study marks the initial phase of refining analytical workflows and data interpretation in preparation for the incorporation of substance use assessment into the statewide wastewater surveillance program in New York.


Assuntos
Águas Residuárias , Águas Residuárias/química , New York , Humanos , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Extração em Fase Sólida
15.
Anal Chim Acta ; 1308: 342662, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38740449

RESUMO

BACKGROUND: The ongoing infusion of pharmaceutical and personal care products (PPCPs) into ecosystems sustains a perpetual life cycle and leads to multi-generational exposures. Limited understanding of their environmental impact and their intrinsic ability to induce physiological effect in humans, even at low doses, pose great risks to human health. Few scholarly works have conducted systematic research into the occurrence of PPCPs within potable water systems. Concurrently, the associated monitoring techniques have not been comprehensively examined with regards to the specific nature of drinking water, namely whether the significant presence of disinfectants may influence the detection of PPCPs. RESULTS: A modified approach in terms of detailed investigation of sample preservation and optimization of an in-lab fabricated solid phase extraction (SPE) cartridge filled with DVB-VP and PS-DVB sorbent was proposed. Favorable methodological parameters were achieved, with correlation coefficients spanning from 0.9866 to 0.9998. The LODs of the PPCPs fluctuated from 0.001 to 2 µg L-1, while the LOQs varied from 0.002 to 5 µg L-1. The analysis of spiked samples disclosed a methodological precision of 2.31-9.86 % and a recovery of 52.4-119 %. We utilized the established method for analyzing 14 water samples of three categories (source water, finished water and tap water) from five centralized water supply plants. A total of 24 categories encompassing 72 PPCPs were detected, with the concentrations of PPCPs manifested a marked decrease from source water to finished water and finally to tap water. SIGNIFICANCE: Our research meticulously examined the enhancement and purification effects of widely used commercial SPE cartridges and suggested the use of in-lab fabricated SPE cartridges packed with DVB-VP and PS-DVB adsorbents. We also conducted a systematic evaluation of the need to incorporate ascorbic acid and sodium thiosulfate as preservatives for PPCP measurement, in consideration of the unique characteristics of drinking water matrices, specifically, the significant concentration levels of disinfectants. Furthermore, the proposed method was effectively employed to study the presence of PPCPs in source water, finished water, and tap water collected from centralized water supply plants.


Assuntos
Extração em Fase Sólida , Poluentes Químicos da Água , Extração em Fase Sólida/métodos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Preparações Farmacêuticas/análise , Abastecimento de Água , Água Potável/análise , Cosméticos/análise , Cosméticos/química , Monitoramento Ambiental/métodos
16.
Sci Rep ; 14(1): 8217, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589481

RESUMO

The present study of a novel metal-organic framework containing Fe single atoms doped on electrospun carbon nanofibers (Fe SA-MOF@CNF) based on dispersive micro solid phase extraction (D-µ-SPE) using HPLC-PDA for detection tartrazine in fake saffron samples was designed. The Fe SA-MOF@CNF sorbent was extensively characterized through various techniques including N2 adsorption-desorption isotherms, X-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared (FTIR) spectroscopy. The specific area of surface of the sorbent was 577.384 m2/g. The study variables were optimized via the central composite design (CCD), which included a sorbent mass of 15 mg, a contact time of 6 min, a pH of 7.56, and a tartrazine concentration of 300 ng/ml. Under the optimum condition, the calibration curve of this method was linear in the range of 5-1000 ng/mL, with a correlation coefficient of 0.992. The LOD and LOQ values were ranged 0.38-0.74 and 1.34-2.42 ng/ml, respectively. This approach revealed significant improvements, including high extraction recovery (98.64), recovery rates (98.43-102.72%), and accuracy (RSDs < 0.75 to 3.6%). the enrichment factors were obtained in the range of 80.6-86.4 with preconcentration factor of 22.3. Consequently, the D-µ-SPE method based on synthesized Fe SA-MOF@CNF could be recommended as a sustainable sorbent for detecting tartrazine in saffron samples.


Assuntos
Crocus , Estruturas Metalorgânicas , Tartrazina , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida/métodos , Corantes
17.
Wei Sheng Yan Jiu ; 53(2): 288-293, 2024 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-38604966

RESUMO

OBJECTIVE: To establish a method for the simultaneous determination of 6 benzodiazepine sedatives residue in aquatic products by high performance liquid chromatography-triple quadrupole mass spectrometry. METHODS: The samples were extracted with acetonitrile and purified by C_(18 )solid phase extraction column. The sample solution was separated by Waters ACQUITY UPLC BEH C_(18 )column(2.1 mm×50 mm, 1.7 µm) using 0.1% formic acid and methanol as mobile phase for gradient elution, determined in multiple reaction monitoring mode and quantified by internal standard method. RESULTS: Six benzodiazepine sedatives had a good linear relationship in the range of 1.0-50.0 µg/L with r>0.9990, the limits of detection and limits of quantification were 0.3 and 1.0 µg/kg. Average recoveries for the analytes at 3 spiked levels ranged from 74.2%-108.0% with relative standard deviations of 1.1%-6.7%(n=6). CONCLUSION: The method is simple, rapid, sensitive and accurate, which is suitable for simultaneous determination of 6 benzodiazepine sedatives residue in aquatic products.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Extração em Fase Sólida , Hipnóticos e Sedativos
18.
Wei Sheng Yan Jiu ; 53(2): 310-315, 2024 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-38604969

RESUMO

OBJECTIVE: To establish a method for twelve halobenzoquinones(HBQs) in drinking water by solid phase extraction-ultra-performance liquid chromatography coupled with electrospray-tandem mass spectrometry(SPE-UPLC-MS/MS). METHODS: The drinking water was acidified with formic acid and concentrated by Bond Elut Plexa solid phase extraction column. The sample solution was separated using Waters ACQUITY HSS T3 column(100 mm×2.1 mm, 1.8 µm) with gradient elution using methanol-water containing 0.1% formic acid as mobile phase. The target compouds were detected in negtive electrospray ionization(ESI~-) and multiple reaction monitoring. RESULTS: The concentration of twelve HBQs showed good linearity in the range 5.0-150.0 ng/mL, respectively, with the correlation coefficients greater than 0.999. The limits of detection(LOD) of twelve HBQs were lower than 2.0 ng/mL, and the limits of quantification(LOQ) for twelve HBQs were lower than 5.0 ng/mL, respectively. The recoveries of three levels in the matrix were 70.0%-84.0%. The matrix effffect was 0.08-0.64. CONCLUSION: The SPE-UPLC-MS/MS method has high sensitivity, good accuracy and fast analysis speed for the detection of halobenzoquinones in drinking water.


Assuntos
Água Potável , Formiatos , Espectrometria de Massas em Tandem , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Água Potável/química , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida
19.
Rapid Commun Mass Spectrom ; 38(11): e9738, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38572671

RESUMO

RATIONALE: Accurate identification of old rice samples from new ones benefits their market circulation and consumers. However, the current detection methods are still not satisfactory because of their insufficient accuracy or (and) time-consuming process. METHODS: Chelating carboxylic acids (CCAs) were selectively extracted from rice, by stirring with chelating resin and a dilute Na2CO3 solution. The green analytical chemistry guidelines for sample preparation were investigated by using the green chemistry calculator AGREE prep. The extractant was determined by liquid chromatography-mass spectrometry (LC/MS), and statistical analysis of the analytical data was carried out to evaluate the significance of the difference by ChiPlot. RESULTS: The limit of quantitation for the CCAs is in the range of 1 to 50 ng/mL, with a reasonable reproducibility. The CCAs in 23 rice samples were determined within a wide concentration range from 0.03 to 1174 µg/g. Intriguingly, the content of citric acid, malonic acid, α-ketoglutaric acid and cis-aconite acid in new rice was each found to be distinctively higher than that in old rice by several times. Even mixtures of old and new rice were found to show much difference in the concentration of citric acid and malic acid. CONCLUSION: A green analytical method has been developed for the simultaneous determination of CCAs by LC/MS analysis, and the identification of old rice samples from new ones was easily carried out according to their CCA content for the first time. The results indicated that the described method has powerful potential for the accurate identification of old rice samples from new ones.


Assuntos
Espectrometria de Massa com Cromatografia Líquida , Oryza , Cromatografia Líquida/métodos , Ácidos Carboxílicos , Oryza/química , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Ácido Cítrico , Cromatografia Líquida de Alta Pressão/métodos , Extração em Fase Sólida
20.
Anal Methods ; 16(16): 2505-2512, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38584507

RESUMO

Solid phase extraction (SPE) and liquid chromatographic (LC) separation of nucleobases and nucleosides are challenging due to the high hydrophilicity of these compounds. Herein we report a novel on-line SPE-LC-MS/MS method for their quantification after pre-column derivatization with chloroacetaldehyde (CAA). The method proposed is selective and sensitive with limits of detection at the nano-molar level. Analysis of urine and saliva samples by using this method is demonstrated. Adenine, guanine, cytosine, adenosine, guanosine, and cytidine were found in the range from 0.19 (guanosine) to 1.83 µM (cytidine) in urine and from 0.015 (guanosine) to 0.79 µM (adenine) in saliva. Interestingly, methylation of cytidine was found to be significantly different in urine from that in saliva. While 5-hydroxymethylcytidine was detected at a very low level (<0.05 µM) in saliva, it was found to be the most prominent methylated cytidine in urine at a high level of 3.33 µM. Since on-line SPE is deployed, the proposed LC-MS/MS quantitative assay is convenient to carry out and offers good assay accuracy and repeatability.


Assuntos
Nucleosídeos , Saliva , Extração em Fase Sólida , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Humanos , Extração em Fase Sólida/métodos , Saliva/química , Cromatografia Líquida/métodos , Nucleosídeos/urina , Nucleosídeos/análise , Limite de Detecção , Espectrometria de Massa com Cromatografia Líquida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA