Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32.188
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38728527

RESUMO

CASE: A 79-year-old woman presented with a periprosthetic fracture 8 years after a total knee arthroplasty (TKA). Radiographs demonstrated tibial implant loosening with severe osteolysis. A high-grade osteosarcoma around the prosthesis was diagnosed, and a supracondylar femoral amputation was performed. After 2 years, no complications have occurred. CONCLUSIONS: A malignant tumor around a TKA is extremely rare. Surgeons should remain vigilant with patients who present with rapidly progressive or very aggressive implant loosening with osteolysis. Owing to its complexity and potentially devastating prognosis, treatment should be guided by a specialist multidisciplinary team. Complex limb salvage procedures or amputation is usually required.


Assuntos
Artroplastia do Joelho , Neoplasias Ósseas , Osteossarcoma , Humanos , Feminino , Osteossarcoma/cirurgia , Osteossarcoma/diagnóstico por imagem , Artroplastia do Joelho/efeitos adversos , Idoso , Neoplasias Ósseas/cirurgia , Neoplasias Ósseas/diagnóstico por imagem , Amputação Cirúrgica , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/diagnóstico por imagem , Falha de Prótese
2.
J Bodyw Mov Ther ; 38: 60-66, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38763614

RESUMO

The use of routine ionizing imaging in identify and classify patients with dislocation or infection after surgery has some medical contraindication, in addition to risks associated with the ionizing load and elevated costs. A novel, less expensive and non-ionizing imaging technique, called infrared thermal imaging, can be proposed as a complementary method to routinely evaluate hip prosthesis patients and track their inflammation response following serious complications. Here we report a case of a total hip prosthesis which was dislocated during inpatient rehabilitation, and ultimately reduced without surgical procedure. During the process, routine clinical and radiographic diagnosis was complemented with an infrared examination. The infrared images were easy to take bedside, without direct contact with the area of surgery, and well tolerated. After the dislocation reduction, the thermal imaging procedure provided important feedbacks on the local inflammation, helping to exclude other complications such as the infections.


Assuntos
Prótese de Quadril , Humanos , Termografia/métodos , Artroplastia de Quadril/reabilitação , Artroplastia de Quadril/métodos , Artroplastia de Quadril/efeitos adversos , Feminino , Falha de Prótese , Masculino , Luxação do Quadril , Raios Infravermelhos , Idoso , Pessoa de Meia-Idade
3.
Jt Dis Relat Surg ; 35(2): 443-447, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38727127

RESUMO

While the usual etiology of slipped capital femoral epiphysis (SCFE) is idiopathic, there are many other factors that increase the predisposition to slippage. Chemotherapy can be one of them. In this article, we report a rare case of acute SCFE after tumor prosthesis implantation in a patient who received chemotherapy. A 10-year-old girl with osteosarcoma of the right distal femur underwent (neo-) adjuvant chemotherapy, wide tumor resection, and reconstruction using a growing tumor prosthesis and a short non-cemented femoral stem. Half a year after implantation, she developed aseptic loosening. Revision surgery was performed using a hydroxyapatite (HA)-coated cementless femoral stem. Postoperative plain radiographs revealed SCFE that was treated by closed reduction and screw fixation. The patient recovered without complications, and unaffected hip showed no radiographic signs of slippage on follow-up. The forces of implanting a tumor prosthesis, particularly with a non-cemented stem, can increase the risk of an acute SCFE. The controversy over prophylactic pinning of the uninvolved hip in chemotherapy-associated SCFE is unresolved. Pinning can be considered only in the presence of abnormal prodromal radiological findings.


Assuntos
Neoplasias Ósseas , Neoplasias Femorais , Osteossarcoma , Escorregamento das Epífises Proximais do Fêmur , Humanos , Feminino , Criança , Escorregamento das Epífises Proximais do Fêmur/cirurgia , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem , Neoplasias Femorais/cirurgia , Osteossarcoma/tratamento farmacológico , Osteossarcoma/cirurgia , Neoplasias Ósseas/tratamento farmacológico , Neoplasias Ósseas/cirurgia , Reoperação , Falha de Prótese , Radiografia , Desenho de Prótese , Quimioterapia Adjuvante/efeitos adversos , Resultado do Tratamento
4.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742736

RESUMO

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Falha de Prótese , Humanos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ecocardiografia Transesofagiana , Masculino , Resultado do Tratamento , Feminino , Idoso , Reoperação
5.
Ann Plast Surg ; 92(6): 621-624, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38717197

RESUMO

ABSTRACT: The unique dual-lumen and baffle design of the IDEAL IMPLANT Structured Saline breast implant gives it specific advantages over both silicone gel-filled and the original saline-filled implants. This internal baffle structure also gives it an appearance on various radiologic imaging studies that may be misinterpreted as a rupture because of similarities to the well-known radiologic appearance of a ruptured silicone gel implant. Patients may present with various misinterpreted imaging studies, highlighting the need for plastic surgeons and radiologists to be familiar with the normal appearance of the intact IDEAL IMPLANT and be able to distinguish it from a ruptured IDEAL IMPLANT. The radiology findings must be correlated with the clinical findings, or an intact IDEAL IMPLANT misdiagnosed as ruptured, may cause unnecessary patient worry, and may prompt unnecessary surgery for removal or replacement.


Assuntos
Implantes de Mama , Remoção de Dispositivo , Erros de Diagnóstico , Falha de Prótese , Humanos , Implantes de Mama/efeitos adversos , Feminino , Procedimentos Desnecessários , Implante Mamário/efeitos adversos , Implante Mamário/métodos , Adulto , Desenho de Prótese , Géis de Silicone , Solução Salina , Pessoa de Meia-Idade
6.
JACC Cardiovasc Interv ; 17(9): 1106-1115, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38749590

RESUMO

BACKGROUND: Unintended deformation of implanted coronary stents can lead to loss of coronary access, stent thrombosis and coronary events during follow-up. The incidence, mechanisms and clinical outcomes of unintended stent deformations (USD) during complex bifurcation stenting are not well characterized. OBJECTIVES: In a prespecified analysis of the OCTOBER (European Trial on Optical Coherence Tomography Optimized Bifurcation Event Reduction) trial, we aimed to: 1) determine the incidence and characterize mechanisms of USD identified by optical coherence tomography (OCT); and 2) evaluate physician's detection and correction of accidental abluminal rewiring and USD. METHODS: OCT scans were analyzed for accidental abluminal rewiring and USD. When USD was identified, the plausible mechanism was determined by analysis of all procedural OCT scans and the corresponding angiograms. RESULTS: USD was identified by the core lab in 9.3% (55/589) of OCT-guided cases. Accidental abluminal rewiring was the cause in 44% (24/55), and guide catheter collision was the cause in 40% (22/55) of cases. USD was found in 18.5% of all cases with left main bifurcation percutaneous coronary intervention. The total incidence of abluminal rewiring was 33 in 32 OCT-guided cases (5.4%) and was corrected by physicians in 18 of 33 appearances (54.5%). The 2-year major adverse cardiac event rate for patients with untreated USD (n = 30) was 23.3%, whereas patients with confirmed or possibly corrected USD (n = 25) had no events during follow-up. CONCLUSIONS: USD was associated with adverse procedural complications and cardiac events during follow-up when not identified and corrected. The predominant mechanisms were undetected abluminal rewiring and guide catheter collision. Left main bifurcation percutaneous coronary intervention was a particular risk with USD detected in 18.5% of cases.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Desenho de Prótese , Stents , Tomografia de Coerência Óptica , Humanos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Masculino , Feminino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Europa (Continente) , Fatores de Tempo , Falha de Prótese , Valor Preditivo dos Testes
8.
Clin Orthop Surg ; 16(2): 251-258, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38562641

RESUMO

Background: The purpose of this study was to evaluate the clinical and radiological outcomes of high-flexion total knee arthroplasty (TKA) using Vega Knee System (B. Braun, Aesculap) at a long-term follow-up and to analyze the implant survivorship. Methods: We enrolled 165 patients (232 knees) with a minimum 7-year follow-up after TKA (VEGA Knee System). For clinical assessment, range of motion (ROM), Knee Injury and Osteoarthritis Outcome Score (KOOS), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) were used. For radiologic assessment, hip-knee-ankle angle, component position, and the existence of radiolucent lines and loosening were used. Survival analysis was conducted using the Kaplan-Meier method. Results: The mean follow-up period was 9.8 years. The mean ROM increased from 124.4° to 131.4° at the final follow-up. The WOMAC score decreased from 38.5 to 17.4 at the final follow-up (p < 0.001). All 5 subscales of the KOOS improved at the final follow-up (all subscales, p < 0.001). Revision TKA was performed in 10 cases (4.3%), which included 9 cases of aseptic loosing and 1 case of periprostatic joint infection. Of the 9 aseptic loosening cases (3.9%), 8 cases (3.4%) were loosening of the femoral component and 1 case (0.4%) was loosening of the tibial component. When revision for any reason was considered an endpoint, the 10-year survivorship was 96.2% (95% confidence interval [CI], 93.9%-98.5%). On the other hand, when revision for aseptic loosening was considered the endpoint, the 10-year survivorship was 96.6% (95% CI, 94.4%-98.8%). Conclusions: The Vega Knee System provided good clinical results in the long-term follow-up period. Although the VEGA Knee System showed acceptable implant survivorship, loosening of the femoral component occurred in about 3.4% of the patients. For more accurate evaluation of the survivorship of high-flexion design TKA with a short posterior flange, it is necessary to conduct more long-term follow-up studies targeting diverse races, especially Asians who frequently perform high-flexion activities.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite , Humanos , Artroplastia do Joelho/métodos , Falha de Prótese , Resultado do Tratamento , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite/cirurgia , Reoperação , Amplitude de Movimento Articular , Desenho de Prótese , Seguimentos , Estudos Retrospectivos
9.
Acta Orthop ; 95: 157-165, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38597226

RESUMO

BACKGROUND AND PURPOSE:  Different marker-selection methods are applied to represent implant and tibial segments in radiostereometric analysis (RSA) studies of total knee arthroplasty (TKA). Either a consistent set of markers throughout subsequent RSA examinations ("consistent-marker method") is used or all available markers at each follow-up ("all-marker method"). The aim of this secondary analysis was to compare marker-selection methods on individual and group level TKA migration results. METHODS:  Data from a randomized RSA study with 72 patients was included. Tibial baseplate migration was evaluated at 3 months, 1, 2, and 5 years postoperatively with both marker-selection methods. Additionally, migration was calculated using 5 fictive points, either plotted based on the consistent set of markers or all available markers. RESULTS:  Migration could be calculated with both marker-selection methods for 248 examinations. The same prosthesis and bone markers (n = 136), different prosthesis markers (n = 71), different bone markers (n = 21), or different prosthesis and bone markers (n = 20) were used. The mean difference in maximum total point motion (MTPM) between all examinations was 0.02 mm, 95% confidence interval -0.26 to 0.31 mm. 5 implants were classified as continuously migrating with the consistent-marker method versus 6 implants (same 5 plus one additional implant) with the all-marker method. Using fictive points, fewer implants were classified as continuously migrating in both marker-selection methods. Differences between TKA groups in mean MTPM were comparable with both marker-selection methods, also when fictive points were used. CONCLUSION:  Estimated group differences in mean MTPM were similar between marker-selection methods, but individual migration results differed. The latter has implications when classifying implants for estimated risk of future loosening.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Seguimentos , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Osteoartrite do Joelho/cirurgia
10.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(4): 455-460, 2024 Apr 15.
Artigo em Chinês | MEDLINE | ID: mdl-38632066

RESUMO

Objective: To explore the short-term effectiveness of hip revision surgery guided by artificial intelligence preoperative planning (AIHIP) system. Methods: The clinical data of 22 patients (23 hips) who were admitted between June 2019 and March 2023 and met the selection criteria were retrospectively analyzed. There were 12 males and 10 females with an average age of 69.7 years (range, 44-90 years). There were 19 hips in the first revision, 3 hips in the second revision, and 1 hip in the third revision. The causes of revision included 12 hips with prosthesis loosening, 4 hips with acetabular cup loosening, 3 hips with osteolysis, 2 hips with acetabular dislocation, 1 hip with postoperative infection, and 1 hip with prosthesis wear. There were 6 hips in stage ⅡA, 9 hips in stage ⅡB, 4 hips in stage ⅡC, 3 hips in stage ⅢA, and 1 hip in stage ⅢB according to Paprosky staging of acetabular bone defect. The replacement of prosthesis type, operation time, hospitalization stay, ground active condition, and postoperative infection, fracture, prosthesis loosening, and other adverse events were recorded. The function of the affected limb was evaluated by Harris score before operation, at 1 week and 6 months after operation, and the range of motion of the hip joint was compared before operation and at 6 months after operation. Results: The operation time was 85-510 minutes, with an average of 241.8 minutes; the hospitalization stay was 7-35 days, with an average of 15.2 days; the time of disassociation from the walker was 2-108 days, with an average of 42.2 days. All the 22 patients were followed up 8-53 months (mean, 21.7 months). No adverse events such as prosthesis loosening or infection occurred in the rest of the patients, except for postoperative hematoma of the thigh in 1 patient and dislocation of the hip in 1 hip. The matching degree of acetabular cup was completely matched in 22 hips and mismatched in 1 hip (+2), the matching rate was 95.65%. The matching degree of femoral stem was completely matched in 22 hips and generally matched in 1 hip (-1), and the matching rate was 100%. The Harris scores were 55.3±9.8 and 89.6±7.2 at 1 week and 6 months after operation, respectively, which significantly improved when compared with before operation (33.0±8.6, P<0.05), and further improved at 6 months after operation than at 1 week after operation ( P<0.05). The function of hip joint was evaluated by Harris score at 6 months after operation, and 21 hips were good and 2 hips were moderate, which could meet the needs of daily life. The range of motion of hip joint was (111.09±10.11)° at 6 months after operation, which was significantly different from (79.13±18.50)° before operation ( t=-7.269, P<0.001). Conclusion: AIHIP system can improve the accuracy of revision surgery, reduce the difficulty of surgery, and achieve good postoperative recovery and satisfactory short-term effectiveness.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Masculino , Feminino , Humanos , Idoso , Falha de Prótese , Reoperação , Estudos Retrospectivos , Inteligência Artificial , Seguimentos , Resultado do Tratamento , Articulação do Quadril/cirurgia , Acetábulo/cirurgia , Complicações Pós-Operatórias , Luxações Articulares/cirurgia
11.
BMC Musculoskelet Disord ; 25(1): 277, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600536

RESUMO

INTRODUCTION: The number of primary and revision Total Knee Arthroplasty (TKA) cases are expected to increase in future. There are various advantages and disadvantage to employing either of the two main types of stem fixation methods - cemented or hybrid technique. This review aimed to study the most optimal fixation method for revision TKAs by comparing radiological outcomes and re-revision rates. METHODS: A systematic review and meta-analysis was performed using PubMed and Cochrane Library from 2010 to identify studies explicitly comparing outcomes between cemented against hybrid fixation revision TKA techniques, with a minimum follow up of at least 24 months. A total of 8 studies was included in this review. Egger's test and visual inspection of the funnel plot did not reveal publication bias. RESULTS: There was no statistically significant difference in radiological failure and loosening (OR 0.79, CI 0.37-1.66, I2 = 29%, p = 0.22), all causes of re-revision (OR 1.03, CI 0.73-1.44, I2 = 0%, p = 0.56) and aseptic revision (OR 0.74, CI 0.27-2.02, I2 = 0%, p = 0.41) between cemented and hybrid techniques. Functional and pain outcomes compared between the two fixation techniques were largely similar across the studies included in this meta-analysis. CONCLUSION: Despite a trend favouring hybrid stems in revision TKA, current evidence revealed that radiological outcomes and re-revision rates are largely similar between cemented and hybrid fixation techniques.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Cimentos Ósseos/uso terapêutico , Exame Físico , Desenho de Prótese , Falha de Prótese , Reoperação/métodos , Resultado do Tratamento
14.
Arch Orthop Trauma Surg ; 144(5): 2421-2428, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38609679

RESUMO

BACKGROUND: Femoral stem fracture following total hip arthroplasty (THA) is an infrequent but nevertheless devastating complication, with an increasing worldwide prevalence as demand for primary THA continues to increase. The aim of this study was to perform a systematic review and meta-analysis of risk factors for femoral stem fracture to help identify at risk patients. METHODS: A systematic search was conducted on EMBASE, MEDLINE and AMED to identify relevant studies. Data regarding study design, source, population, intervention, and outcomes was collated. Data extraction was performed on a custom form generated using Cochrane recommended methodology and analysis of risk factors performed including odds ratios (ORs) with 95% confidence intervals (CIs). RESULTS: A total of 15 studies reporting a total of 402 stem fractures in 49 723 THAs were identified. The median time from index procedure to stem fracture was 68 months (IQR 42.5-118) whilst mean age at index surgery was 61.8 years (SD 6.9). Male gender (OR = 3.27, 95% CI = 2.59-4.13, p < 0.001), patient weight above 80 kg (OR = 3.55, 95% CI = 2.88-4.37, p < 0.001), age under 63 years (OR = 1.22, 95% CI = 1.01-1.49, p < 0.001), varus stem alignment (OR = 5.77, 95% CI = 3.83-8.7, p < 0.001), use of modular implants (OR = 1.95, 95% CI = 1.56-2.44, p < 0.01) and undergoing revision arthroplasty (OR = 3.33, 95% CI = 2.70-4.1, p < 0.001) were significant risk factors for prosthetic stem fracture. A risk window of 15 years post-surgery was identified. CONCLUSIONS: This review concludes that patient weight, younger age, male sex, varus stem alignment, revision arthroplasty and use of modular stems are significant risk factors for femoral stem fracture. Modifying these risk factors where possible may help reduce incidence of femoral stem fracture in at risk patients.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Humanos , Artroplastia de Quadril/efeitos adversos , Fatores de Risco , Fraturas do Fêmur/cirurgia , Fraturas do Fêmur/epidemiologia , Fraturas do Fêmur/etiologia , Masculino , Falha de Prótese , Feminino , Prótese de Quadril/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade
15.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38625551

RESUMO

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Reoperação , Humanos , Artroplastia do Joelho/métodos , Artroplastia do Joelho/instrumentação , Alemanha/epidemiologia , Reoperação/estatística & dados numéricos , Masculino , Idoso , Feminino , Tíbia/cirurgia , Pessoa de Meia-Idade , Cimentos Ósseos
16.
Arch Orthop Trauma Surg ; 144(5): 2067-2076, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38642161

RESUMO

BACKGROUND: Polyaryl-ether-ether-ketone (PEEK) has gained popularity as a substrate for orthopaedic hardware due to its desirable properties such as heat and deformation resistance, low weight, and ease of manufacturing. However, we observed a relatively high failure rate of PEEK-based hinges in a distal femur reconstruction system. In this study, we aimed to evaluate the proportion of patients who experienced implant failure, analyse the mechanism of failure, and document the associated clinical findings. METHODS: We conducted a retrospective cohort study, reviewing the medical charts of 56 patients who underwent distal femur resection and reconstruction with a PEEK Optima hinge-based prosthesis between 2004 and 2018. Concurrently, we performed a clinical and biomechanical failure analysis. RESULTS: PEEK component failure occurred in 21 out of 56 patients (37.5%), with a mean time to failure of 63.2 months (range: 13-144 months, SD: 37.9). The survival distributions of PEEK hinges for males and females were significantly different (chi-square test, p-value = 0.005). Patient weight was also significantly associated with the hazard of failure (Wald's test statistic, p-value = 0.031). DISCUSSION: Our findings suggest that PEEK hinge failure in a distal femur reconstruction system is correlated with patient weight and male gender. Retrieval analysis revealed that failure was related to fretting and microscopic fractures due to cyclic loading, leading to instability and mechanical failure of the PEEK component in full extension. Further assessment of PEEK-based weight bearing articulating components against metal is warranted.


Assuntos
Benzofenonas , Fêmur , Cetonas , Polietilenoglicóis , Polímeros , Desenho de Prótese , Falha de Prótese , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fêmur/cirurgia , Adulto , Idoso de 80 Anos ou mais
17.
Arch Orthop Trauma Surg ; 144(5): 2019-2026, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581441

RESUMO

BACKGROUND: Routine total hip arthroplasty (THA) using a short cemented stem as compared with a standard length cemented stem may have benefits in terms of stress distribution, bone preservation, stem subsidence and ease of revision surgery. Two senior arthroplasty surgeons transitioned their routine femoral implant from a standard 150 mm Exeter V40 cemented stem to a short 125 mm Exeter V40 cemented stem for all patients over the course of several years. We analysed revision rates, adjusted survival, and PROMS scores for patients who received a standard stem and a short stem in routine THA. METHODS: All THAs performed by the two surgeons between January 2011 and December 2021 were included. All procedures were performed using either a 150 mm or 125 mm Exeter V40 stem. Demographic data, acetabular implant type, and outcome data including implant survival, reason for revision, and post-operative Oxford Hip Scores were obtained from the New Zealand Joint Registry (NZJR), and detailed survival analyses were performed. Primary outcome was revision for any reason. Reason for revision, including femoral or acetabular failure, and time to revision were also recorded. RESULTS: 1335 THAs were included. 516 using the 150 mm stem and 819 using the 125 mm stem. There were 4055.5 and 3227.8 component years analysed in the standard stem and short stem groups respectively due to a longer mean follow up in the 150 mm group. Patient reported outcomes were comparable across all groups. Revision rates were comparable between the standard 150 mm stem (0.44 revisions/100 component years) and the short 125 mm stem (0.56 revisions/100 component years) with no statistically significant difference found (p = 0.240). CONCLUSION: Routine use of a short 125 mm stem had no statistically significant impact on revision rate or PROMS scores when compared to a standard 150 mm stem. There may be benefits to routine use of a short cemented femoral implant.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Prótese de Quadril , Medidas de Resultados Relatados pelo Paciente , Desenho de Prótese , Reoperação , Humanos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Reoperação/estatística & dados numéricos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Falha de Prótese , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Cimentação
18.
Arch Orthop Trauma Surg ; 144(5): 2273-2281, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38615291

RESUMO

INTRODUCTION: Following total knee arthroplasty (TKA), there is a significant decline in periprosthetic bone mineral density (BMD), potentially resulting in complications such as prosthetic loosening, periprosthetic fracture, and influencing the postoperative recovery. The objective of this study was to summarize the factors influencing periprosthetic BMD in TKA from existing studies. METHODS: A comprehensive systematic search was performed in 4 databases: Pubmed, Embase, Web of Science, and Cochrane Library. The last search was carried out on October 12, 2023. We used the keywords ''total knee arthroplasty'', ''bone mineral density'' and each of them combined with ''tibia'' and ''femur'' to identify all relevant articles reporting about potential impact factors influencing the periprosthetic BMD in patients after TKA. RESULTS: Out of 1391 articles, 22 published from 2001 to 2023 were included in this systematic review. Following eligibility screening, six significant categories affecting periprosthetic BMD were recognized: prosthesis type, design of stem, coating, body weight, cement, and peg distance. CONCLUSION: Mobile-bearing prostheses, modular polyethylene design, short stems, cruciform stems, avoidance of bone cement, higher body mass index, titanium nitride coating, and a smaller medial peg distance could potentially benefit periprosthetic BMD. Comprehensive consideration of diverse factors influencing periprosthetic BMD before surgery and collaboration with post-operative drug therapy are essential. TRIAL REGISTRY: The PROSPERO registration number is CRD42023472030.


Assuntos
Artroplastia do Joelho , Densidade Óssea , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Desenho de Prótese , Fraturas Periprotéticas/etiologia , Falha de Prótese
19.
Eur J Orthop Surg Traumatol ; 34(4): 2155-2162, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38565783

RESUMO

INTRODUCTION: Increasing interest in the use of anatomical stems has developed as the prevalence of periprosthetic fractures (PPFs) continues to increase. The primary aim of this study was to determine the long-term survivorship and PPF rate of an anatomical femoral stem in a single UK centre. PATIENTS AND METHODS: Between 2000 and 2002, 94 consecutive THAs were performed using the 170 mm Lubinus SP II anatomical femoral stem in our institution. Patient demographics, operative details and clinical outcomes were collected prospectively in an arthroplasty database. Patient records and national radiographic archives were reviewed finally at a mean of 21.5 years (SD 0.7) following surgery to identify occurrence of subsequent revision surgery, dislocation or periprosthetic fracture. RESULTS: Mean patient age at surgery was 65.8 years (SD 12.5, 34-88 years). There were 48 women (51%). Osteoarthritis was the operative indication in 88 patients (94%). Analysis of all-cause THA failure demonstrated a survivorship of 98.5% (95% confidence interval [CI], 98.0-99.3%) at 10 years and 96.7% (94.5-98.9%) at 21 years. The 20-year stem survival for aseptic loosening was 100% with no cases of significant lysis found (lucent line > 2 mm) and no stems required revision. Patient demographics did not appear to influence risk of revision (p > 0.05). There were 2 revisions in total (2 for acetabular loosening with original stems retained). There were no PPFs identified at mean 21.5 year follow-up and 5 dislocations (5%). CONCLUSIONS: The Lubinus SP II 170 mm stem demonstrated excellent survivorship and negligible PPF rates over 20 years following primary THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Falha de Prótese , Reoperação , Humanos , Idoso , Feminino , Masculino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Reoperação/estatística & dados numéricos , Adulto , Seguimentos , Reino Unido , Desenho de Prótese , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia
20.
BMC Musculoskelet Disord ; 25(1): 312, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38649874

RESUMO

BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed. There were no exclusions for BMI or other factors. We examined the data with Kaplan-Meier survival analysis. The primary endpoint for survival was mechanical failure of the modular neck-body junction. RESULTS: The survivorship of this device in 172 subjects was 100% with none experiencing mechanical failure of the modular junction at an average of 15 years. 60 patients died of causes unrelated to their THA and 9 patients were lost to follow-up. There were three early (≤ 12 months) dislocations (1.7%), and seven total dislocations (4.1%). 16 patients underwent reoperations during the follow-up period, none for any complication of the modular junction. Radiographic results showed well-fixed femoral stems in all cases. There were no leg length discrepancies of greater than 10 mm, and 85% were within 5 mm. CONCLUSION: There were no mechanical failures of the modular junction in any of the subjects over the average 15-year period, demonstrating that this dual-modular design is not associated with increased failure rates. We achieved a 1.7% early dislocation rate and a 4.1% total dislocation rate without any clinically significant leg length discrepancies.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Humanos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Seguimentos , Osteoartrite do Quadril/cirurgia , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estimativa de Kaplan-Meier , Reoperação/estatística & dados numéricos , Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA