Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 132(3): 707-716, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32833716

RESUMO

BACKGROUND: Despite their usefulness in perioperative and acute care settings, factor-Xa inhibitor-specific assays are scarcely available, contrary to heparin anti-Xa assay. We assessed whether the heparin anti-Xa assay can (1) be used as a screening test to rule out apixaban, rivaroxaban, fondaparinux, and danaparoid levels that contraindicate invasive procedures according to current guidelines (>30 ng·mL-1, >30 ng·mL-1, >0.1 µg·mL-1, and >0.1 IU·mL-1, respectively), (2) quantify the anticoagulant level if found significant, that is, if it exceeded the abovementioned threshold. METHODS: In the derivation cohort then in the validation cohort, via receiver operating characteristics (ROC) curve analysis, we evaluated the ability of heparin anti-Xa assay to detect levels of factor-Xa inhibitors above or below the abovementioned safety thresholds recommended for an invasive procedure (screening test). Among samples with relevant levels of factor-Xa inhibitor, we determined the conversion factor linking the measured level and heparin anti-Xa activity in a derivation cohort. In a validation cohort, the estimated level of each factor-Xa inhibitor was thus inferred from heparin anti-Xa activity. The agreement between measured and estimated levels of factor-Xa inhibitors was assessed. RESULTS: Among 989 (355 patients) and 756 blood samples (420 patients) in the derivation and validation cohort, there was a strong linear relationship between heparin anti-Xa activities and factor-Xa inhibitors measured level (r = 0.99 [95% confidence interval {CI}, 0.99-0.99]). In the derivation cohort, heparin anti-Xa activity ≤0.2, ≤0.3, <0.1, <0.1 IU·mL-1 reliably ruled out a relevant level of apixaban, rivaroxaban, fondaparinux, and danaparoid, respectively (area under the ROC curve ≥0.99). In the validation cohort, these cutoffs yielded excellent classification accuracy (≥96%). If this screening test indicated relevant level of factor-Xa inhibitor, estimated and measured levels closely agreed (Lin's correlation coefficient close to its maximal value: 95% CI, 0.99-0.99). More than 96% of the estimated levels fell into the predefined range of acceptability (ie, 80%-120% of the measured level). CONCLUSIONS: A unique simple test already widely used to assay heparin was also useful for quantifying these 4 other anticoagulants. Both clinical and economic impacts of these findings should be assessed in a specific study.


Assuntos
Testes de Coagulação Sanguínea , Coagulação Sanguínea/efeitos dos fármacos , Sulfatos de Condroitina/sangue , Dermatan Sulfato/sangue , Monitoramento de Medicamentos , Inibidores do Fator Xa/sangue , Fondaparinux/sangue , Heparitina Sulfato/sangue , Pirazóis/sangue , Piridonas/sangue , Rivaroxabana/sangue , França , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Clin Chem Lab Med ; 58(11): 1921-1930, 2020 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-32441664

RESUMO

Objectives Chromogenic anti-activated factor X (FXa) assays are currently the "gold standard" for monitoring indirect anticoagulants. However, anti-FXa has been shown to vary according to the choice of reagents. In the present study, the performance of anti-FXa measurement was evaluated in order to gain more insight into the clinical applications. Furthermore, the longitudinal coefficient of variation (CV) was studied to investigate whether there is improvement over time. Methods Laboratory tests results were evaluated for samples spiked with unfractionated heparin (UFH), low-molecular-weight-heparin (LMWH), fondaparinux and danaparoid sodium. External quality assessment (EQA) data from multiple years were used from more than 100 laboratories. Results Comparison of the results for all methods showed significant differences in measured values between the frequently used methods (ANOVA: p < 0.001). The largest differences were observed for LMWH and UFH measurements. These differences may be caused by differences in method composition, such as the addition of dextran sulphate. Substantial interlaboratory variation in anti-FXa monitoring was observed for all parameters, particularly at low concentrations. Our results showed that below 0.35 IU/mL, the CVs for UFH and LMWH increase dramatically and results below this limit should be used with caution. Conclusions Our study demonstrates that the choice of the anti-FXa method is particularly important for UFH and LMWH measurement. The variation in measurements may have an effect on clinical implications, such as therapeutic ranges. Furthermore, the longitudinal EQA data demonstrated a constant performance and, in at least 50% of the cases, improvement in the CV% of the anti-Xa results over time.


Assuntos
Sulfatos de Condroitina/sangue , Dermatan Sulfato/sangue , Inibidores do Fator Xa/sangue , Fondaparinux/sangue , Heparina de Baixo Peso Molecular/sangue , Heparitina Sulfato/sangue , Análise Química do Sangue/métodos , Monitoramento de Medicamentos , Humanos , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA