Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
PLoS One ; 17(1): e0260079, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35100273

RESUMO

Measurement of N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels has been shown to have clinical significance for diagnosis and management of heart disease in dogs. Evaluation of current reference limits for specific breeds is necessary to ensure the test can accurately distinguish between healthy and diseased animals. The objective of this study is to evaluate the adequacy of currently established NT-proBNP reference limits for clinical use in healthy Salukis. Cardiac health of 33 clinically healthy Salukis was evaluated via echocardiography using available breed standards. Plasma concentrations of NT-proBNP were measured using a commercially available assay. A one-sided 97.5% upper reference limit for the NT-proBNP concentrations was calculated using non-parametric percentile method. The 97.5% upper reference limit was 769 pmol/L (90% CI, 547-1214 pmol/L) for the study dogs. This upper reference limit was within the currently established non-breed specific NT-proBNP upper reference limit of 900 pmol/L. No relationship between sex, age, or body weight on plasma levels of NT-proBNP was noted. Results of this study supports the use of currently available non-breed specific NT-proBNP cut-off values for clinical evaluation of healthy Salukis.


Assuntos
Doenças do Cão/diagnóstico , Cardiopatias/diagnóstico , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Animais , Biomarcadores/sangue , Cães , Ecocardiografia , Feminino , Masculino , Peptídeo Natriurético Encefálico/normas , América do Norte , Fragmentos de Peptídeos/normas , Valores de Referência
2.
Crit Care Med ; 49(9): 1481-1492, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33870916

RESUMO

OBJECTIVES: To provide a comparative analysis of conventional heparin-versus bivalirudin-based systemic anticoagulation in adult and pediatric patients supported on extracorporeal membrane oxygenation. DESIGN: Retrospective chart review study of adult and pediatric patients receiving extracorporeal membrane oxygenation from January 1, 2014, to October 1, 2019. SETTING: A large, high-volume tertiary referral adult and pediatric extracorporeal membrane oxygenation center. PATIENTS: Four hundred twenty-four individuals requiring extracorporeal membrane oxygenation support and systemically anticoagulated with either unfractionated heparin (223 adult and 65 pediatric patients) or bivalirudin (110 adult and 24 pediatric patients) were included. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Digital data abstraction was used to retrospectively collect patient details. The majority of both groups were cannulated centrally (67%), and the extracorporeal membrane oxygenation type was predominantly venoarterial (84%). The adult bivalirudin group had a greater occurrence of heparin-induced thrombocytopenia (12% vs 1%; p < 0.01) and was more likely to require postcardiotomy extracorporeal membrane oxygenation (36% vs 55%; p < 0.01). There were no statistical differences between the groups in regards to age, sex, and extracorporeal membrane oxygenation initiation location. The main finding was a reduced mortality in the adult bivalirudin group (odds ratio, 0.39; p < 0.01), whereas no difference was noted in the pediatric group. A significant reduction in the composite transfusion requirement in the first 24 hours was noted in the pediatric bivaluridin group with an odds ratio of 0.28 (p = 0.02). Groups did not differ in regard to laboratories per day, anticoagulant dose adjustments, or ischemic complications. CONCLUSIONS: When compared with heparin-based systemic anticoagulation, bivalirudin demonstrated feasibility and safety as established by the absence of increases in identifiable adverse outcomes while manifesting substantial improvements in hospital mortality in adult patients. Further studies are necessary to corroborate these findings and further elucidate the role of bivalirudin during extracorporeal membrane oxygenation support.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Heparina/normas , Hirudinas/normas , Fragmentos de Peptídeos/normas , Adolescente , Adulto , Anticoagulantes/normas , Anticoagulantes/uso terapêutico , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Fragmentos de Peptídeos/uso terapêutico , Proteínas Recombinantes/normas , Proteínas Recombinantes/uso terapêutico , Estudos Retrospectivos
3.
Clin Chem Lab Med ; 58(2): 314-321, 2020 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-31622239

RESUMO

Background Previous studies have suggested that exercising may induce cardiac damage. Galectin-3 (Gal-3) and soluble suppression of tumorigenicity 2 (ST2) are very interesting biomarkers for heart failure and myocardial fibrosis. We aimed to compare the kinetics of emerging fibrosis cardiac biomarkers as Gal-3 and ST-2 in endurance runners, and recreational runners before and after a running event represented by a marathon and an ultratrail event. Methods Blood samples were taken from 19 healthy non-elite marathon runners (42 km), 27 ultratour runners (67 km), and 14 recreational runners who represented the control group (10 km) just before the run (T0), just after (T1) and 3 h after (T2), in order to analyze Gal-3, ST2, hsTnT, NT-proBNP, CKMB and hsCRP. We compared the percentage of evolution and the slopes obtained from T0 to T1 (pT0T1) and from T1 to T2 (pT1T2), between the different groups of runners participating in three different races. Results Plasma cardiac biomarker concentrations increased significantly from baseline to immediately post-exercise and most of the time decreased over the subsequent 3-h period. For pT0T1 and pT1T2, the markers Gal-3 and ST2 showed a significant difference between types of run (p < 0.05 and p < 0.0001, respectively). During the recovery time, Gal-3 returned to the baseline values but not ST2 which continued to increase. Conclusions Gal-3 and ST2 are considered as a reflection of cardiac fibrosis and remodeling. The evolution of both was different, particularly after the recovery time. ST2 values exceeding cutoff values at any time.


Assuntos
Galectinas/sangue , Proteína 1 Semelhante a Receptor de Interleucina-1/sangue , Adulto , Biomarcadores/sangue , Proteínas Sanguíneas/normas , Proteína C-Reativa/análise , Proteína C-Reativa/normas , Galectinas/normas , Coração/fisiologia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/normas , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/normas , Valores de Referência , Corrida
4.
Clin Biochem ; 77: 7-13, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31843667

RESUMO

OBJECTIVE: To determine the reference ranges of presepsin in term and preterm neonates without infection, with respect to gestational and postnatal age, within the first 28 days of life. METHODS: A total of 144 neonates born at 24-42 weeks' gestation, including healthy term and preterm neonates without clinical signs or symptoms of infection, were included in this prospective observational study. Presepsin measurements included cord blood levels and serum levels on postnatal days 1, 3, 5, 7, 14, 21, and 28. RESULTS: The presepsin values corresponding to the 10th percentile ranged from 240.8 pg/mL (on day 1) to 129.9 pg/mL (on day 28), whereas those corresponding to the 90th percentile ranged from 725.8 pg/mL (on day 1) to 471.6 pg/mL (on day 28). Significantly higher presepsin levels were observed in cesarean deliveries than in spontaneous deliveries (p: 0.012 to <0.001), in gestational ages ≤ 32 weeks than in gestational ages ≥37 weeks (p: <0.05 to <0.001), and in cases with a maternal history of chorioamnionitis than in those without (p: <0.05 to <0.001). CONCLUSION: In conclusion, our findings revealed, for the first time, the reference ranges of presepsin in healthy term and preterm neonates without infection with respect to gestational and postnatal age, sex, and body weight. Presepsin levels within the first 28 days of life seem likely to be affected by the type of delivery, gestational and postnatal age, birth weight, and presence of respiratory distress syndrome or maternal chorioamnionitis.


Assuntos
Receptores de Lipopolissacarídeos/metabolismo , Fragmentos de Peptídeos/metabolismo , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Fragmentos de Peptídeos/normas , Padrões de Referência
5.
Cancer Biother Radiopharm ; 34(8): 498-503, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31424293

RESUMO

Background: Glypican 3 (GPC3), a plasma membrane heparan sulfate proteoglycan, is overexpressed on human hepatocellular carcinoma and may represent a promising biomarker. Several studies have reported peptides that selectively bind to GPC3 and could serve as scaffolds for imaging or therapeutic agents. Materials and Methods: We synthesized variants of two previously published peptides, DHLASLWWGTEL (TJ12P1) and RLNVGGTYFLTTRQ (L5), and evaluated their in vitro binding performance in paired isogenic cell lines, A431(GPC3-) and A431-GPC3+ (G1), as well as the liver cancer cell line HepG2. Using flow cytometry and biolayer interferometry (BLI), we compared the binding of the TJ12P1 and L5 peptide variants to the binding of corresponding scrambled peptides having the same amino acid composition, but in random sequence. Results: While both peptides bound to G1 and HepG2, they also bound to A431. The corresponding scrambled peptides demonstrated greater apparent binding to both G1 and A431 than their specific counterparts. BLI confirmed lack of binding at 0.5-1 µM for both peptides. Conclusions: We conclude that neither TJ12P1 nor L5 variant demonstrates selectivity for GPC3 at concentrations near the reported KD, and that the peptides lack potency or are nonspecific, making them inadequate for use as imaging agents.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Glipicanas/metabolismo , Neoplasias Hepáticas/diagnóstico , Fragmentos de Peptídeos/metabolismo , Fragmentos de Peptídeos/normas , Carcinoma Hepatocelular/metabolismo , Humanos , Técnicas In Vitro , Neoplasias Hepáticas/metabolismo , Células Tumorais Cultivadas
6.
Clin Chem Lab Med ; 57(6): 911-917, 2019 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-30412461

RESUMO

Background The study aim was to evaluate and compare analytical performances and clinical results of ADVIA BNP and PBNP methods using the Centaur XPT platform with those of Access BNP, using the DxI platform and the ECLIA NT-proBNP method, using the Cobas e411 platform, respectively. Methods Limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 20% CV and 10% CV were evaluated according to international standardized protocols. The analytical parameters were assessed throughout a 90-working-day period using three curve calibrations. Results LoB, LoD and LoQ at 20% CV and 10% values of the ADVIA BNP method were 1.0 ng/L, 2.0 ng/L, 3.7 ng/L and 10.2 ng/L, respectively; while those of the ADVIA PBNP method were 1.3 ng/L, 3.0 ng/L, 9.7 ng/L and 22.3 ng/L, respectively. The ADVIA BNP and PBNP methods were able to measure the clinical decision values suggested by international guidelines for diagnosis of heart failure (HF) with an imprecision ≤6%. BNP concentrations measured with the ADVIA and Access methods showed a close linear regression (R=0.9923, n=200); a close linear regression was also found between NT-proBNP concentrations measured with the ADVIA and ECLIA methods (R=0.9954, n=202). However, the ADVIA method measured significantly lower BNP values than the Access method (on average -20.9%), while ADVIA PBNP method measured significantly higher NT-proBNP concentrations than the ECLIA method (on average +17.8%). Conclusions Analytical performances of the BNP and PBNP ADVIA methods are well in accordance with the quality specifications required by international guidelines for diagnosis and follow-up of patients with HF.


Assuntos
Imunoensaio/métodos , Peptídeo Natriurético Encefálico/análise , Fragmentos de Peptídeos/análise , Guias como Assunto , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/patologia , Humanos , Imunoensaio/normas , Limite de Detecção , Peptídeo Natriurético Encefálico/normas , Fragmentos de Peptídeos/normas , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
7.
Clin Chim Acta ; 483: 291-295, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29772213

RESUMO

BACKGROUND: The Enhanced Liver Fibrosis score has been recognized as a non-invasive test for liver fibrosis. However, reference intervals, biological variation and analytical performance have not been studied in detail so far. The aim was to acquire data that are essential for correct interpretation. METHODS: A total of 40 apparently healthy volunteers were evaluated for reference ranges of serum concentration of hyaluronic acid, aminoterminal propeptide of type III collagen, and tissue inhibitor of metalloproteases-1, and calculated ELF score. A subgroup of 20 subjects was evaluated repeatedly for 7 weeks. For all variables, reference intervals, within-subject and between-subject biological variations, reference change values, and the indexes of individuality were assessed. Analytical performance (intermediate precision) and interlaboratory comparison were also evaluated. RESULTS: The reference ranges were 5.1-62.7 µg/L for HA, 3.56-12.6 µg/L for PIIINP, 143.6-265.3 µg/L for TIMP-1, and 7.14-9.55 for the ELF score. The within-subject variations were 32.7, 10.6, 4.2, and 3.2% for HA, PIIINP, TIMP-1, and ELF score, respectively. Similarly, the between-subject variations were 59.0, 13.3, 12.8, and 5.2%. For the ELF score, RCV was 10.1% and II was 0.62. The intermediate precisions were <5%, <6%, and <10% for HA, PIIINP, and TIMP-1, respectively. CONCLUSION: The reference range of the ELF score overlap with the area defined as moderate fibrosis by the manufacturer. High biological variation of HA was diminished by the natural logarithm in the calculation of the ELF score. The use of the ELF score has suitable analytical and acceptable biological performance characteristics for clinical practice. However, the transfer of results evaluated in healthy persons to the populations with chronic liver diseases deserves caution.


Assuntos
Cirrose Hepática/diagnóstico , Índice de Gravidade de Doença , Adulto , Feminino , Voluntários Saudáveis , Humanos , Ácido Hialurônico/normas , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/normas , Pró-Colágeno/normas , Valores de Referência , Inibidor Tecidual de Metaloproteinase-1/normas
9.
Sci Rep ; 7: 45570, 2017 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-28368040

RESUMO

The two most common techniques for absolute protein quantification are based on either mass spectrometry (MS) or on immunochemical techniques, such as western blotting (WB). Western blotting is most often used for protein identification or relative quantification, but can also be deployed for absolute quantification if appropriate calibration standards are used. MS based techniques offer superior data quality and reproducibility, but WB offers greater sensitivity and accessibility to most researchers. It would be advantageous to apply both techniques for orthogonal quantification, but workflows rarely overlap. We describe DOSCATs (DOuble Standard conCATamers), novel calibration standards based on QconCAT technology, to unite these platforms. DOSCATs combine a series of epitope sequences concatenated with tryptic peptides in a single artificial protein to create internal tryptic peptide standards for MS as well as an intact protein bearing multiple linear epitopes. A DOSCAT protein was designed and constructed to quantify five proteins of the NF-κB pathway. For three target proteins, protein fold change and absolute copy per cell values measured by MS and WB were in excellent agreement. This demonstrates that DOSCATs can be used as multiplexed, dual purpose standards, readily deployed in a single workflow, supporting seamless quantitative transition from MS to WB.


Assuntos
Proteínas/análise , Proteínas/normas , Proteoma/análise , Proteoma/normas , Proteômica/métodos , Humanos , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/normas , Padrões de Referência
10.
J Pharm Sci ; 106(5): 1322-1330, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28137696

RESUMO

It was the aim of this study to incorporate a model peptide bivalirudin in self-emulsifying drug delivery system (SEDDS) and compare its storage stability with conventional aqueous solutions. Firstly, bivalirudin lipophilicity was increased via hydrophobic ion pairing using anionic or cationic surfactants. The chosen bivalirudin docusate complex (BIV/AOT) was incorporated into SEDDS composed of 40% (w/w) Cremophor EL, 20% (w/w) Capmul PG-8, and 40% (w/w) propylene glycol with a drug payload of 0.20% (w/w). SEDDS were stable over a wide pH range for at least 7 days at 37°C and showed an immediate bivalirudin release profile. Moreover, aqueous bivalirudin solutions were shown to be most stable between apparent pH 3 and 4. Furthermore, 94.39% and 72.66% of bivalirudin in SEDDS and 10% propylene glycol, respectively, remained intact after 90 days of storage at 25°C ± 2°C, whereas 99.12% and 80.54% were still intact in SEDDS and 10% propylene glycol at 5°C ± 3°C, respectively. Bivalirudin in reconstituted commercially available product Angiomax® was, however, long-term unstable. According to these findings, SEDDS could be considered as a potential bivalirudin stabilization medium against chemical degradation.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Emulsificantes/química , Hirudinas/química , Interações Hidrofóbicas e Hidrofílicas , Fragmentos de Peptídeos/química , Antitrombinas/química , Antitrombinas/normas , Sistemas de Liberação de Medicamentos/normas , Estabilidade de Medicamentos , Armazenamento de Medicamentos/métodos , Armazenamento de Medicamentos/normas , Emulsificantes/normas , Hirudinas/normas , Fragmentos de Peptídeos/normas , Proteínas Recombinantes/química , Proteínas Recombinantes/normas
11.
J Am Geriatr Soc ; 64(11): e189-e194, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27783390

RESUMO

OBJECTIVES: To determine reference values for laboratory tests in individuals aged 85 and older. DESIGN: Cross-sectional cohort study. SETTING: International. PARTICIPANTS: Long Life Family Study (LLFS) participants (N~5,000, age: range 25-110, median 67, 45% male). MEASUREMENTS: Serum biomarkers were selected based on association with aging-related diseases and included complete blood count, lipids (triglycerides, high-density lipoprotein cholesterol, low-density lipoprotein cholesterol, total cholesterol), 25-hydroxyvitamin D2 and D3, vitamin D epi-isomer, diabetes mellitus-related biomarkers (adiponectin, insulin, insulin-like growth factor 1, glucose, glycosylated hemoglobin, soluble receptor for advanced glycation endproduct), kidney disease-related biomarkers (albumin, creatinine, cystatin), endocrine biomarkers (dehydroepiandrosterone, sex-hormone binding globulin, testosterone), markers of inflammation (interleukin 6, high-sensitivity C-reactive protein, N-terminal pro b-type natriuretic peptide), ferritin, and transferrin. RESULTS: Of 38 measured biomarkers, 34 were significantly correlated with age. Summary statistics were generated for all biomarkers according to sex and 5-year age increments from 50 and up after excluding participants with diseases and treatments that were associated with biomarkers. A biomarker data set was also generated that will be useful for other investigators seeking to compare biomarker levels between studies. CONCLUSION: Levels of several biomarkers change with older age in healthy individuals. The descriptive statistics identified herein will be useful in future studies and, if replicated in additional studies, might also become useful in clinical practice. The availability of the reference data set will facilitate appropriate calibration of biomarkers measured in different laboratories.


Assuntos
Contagem de Células Sanguíneas , Glicemia/análise , Proteína C-Reativa , Insulina , Proteínas de Ligação ao Ferro , Lipídeos , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Testosterona , Vitamina D/análogos & derivados , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/análise , Biomarcadores/sangue , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/normas , Proteína C-Reativa/análise , Proteína C-Reativa/normas , Estudos de Coortes , Estudos Transversais , Feminino , Humanos , Insulina/sangue , Insulina/normas , Proteínas de Ligação ao Ferro/sangue , Proteínas de Ligação ao Ferro/normas , Lipídeos/sangue , Lipídeos/normas , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/normas , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/normas , Valores de Referência , Estatística como Assunto , Testosterona/sangue , Testosterona/normas , Estados Unidos , Vitamina D/sangue , Vitamina D/normas
12.
Bioanalysis ; 8(21): 2195-2203, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27678052

RESUMO

AIM: This work set out to realize an idea for a novel means of extracting the peptide therapeutic bivalirudin from human plasma in what would be a uniquely selective means of SPE, a mixed-mode protocol involving electrostatic interactions followed by HILIC. RESULTS: Inter and intra-assay relative error ranged from 3.52 to 8.23%, and 2.37 to 6.90%, respectively. Inter and intra-assay precision ranged from 2.64 to 7.12%, and 0.855 to 2.90%, respectively. Recoveries of 80% were attained, and there was no hint of discernible manifestation of matrix effects. CONCLUSION: The method was shown to perform excellently in the assessment tantamount to method validation. The essence of the extraction method presents a new option for highly selective extraction of peptides from biological matrices.


Assuntos
Análise Química do Sangue/métodos , Hirudinas/sangue , Fragmentos de Peptídeos/sangue , Espectrometria de Massas em Tandem/normas , Análise Química do Sangue/instrumentação , Calibragem , Cromatografia Líquida de Alta Pressão/normas , Hirudinas/isolamento & purificação , Hirudinas/normas , Humanos , Interações Hidrofóbicas e Hidrofílicas , Fragmentos de Peptídeos/isolamento & purificação , Fragmentos de Peptídeos/normas , Proteínas Recombinantes/sangue , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/normas , Extração em Fase Sólida , Eletricidade Estática
13.
J Proteomics ; 146: 133-40, 2016 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-27343760

RESUMO

UNLABELLED: Quantification of the antigens hemagglutinin and neuraminidase in influenza vaccines has been reported using an antibody-free liquid chromatography-mass spectrometry (LC-MS) based method known as MS(E) "Hi3". This approach is based on the average signal intensity of the three most intense tryptic peptides relative to a primary standard. This strategy assumes that the Hi3 signal responses are consistent for all proteins, and therefore comparable to a spiked reference for absolute quantification. This method is much faster than the current standard methods; however, the results can vary significantly which brought the method's accuracy into question. To address this question we generated synthetic proteins comprising a concatenation of the peptides used to quantify the proteins of interest (QconCAT). Complete tryptic digestion of a QconCAT protein produces equal molar peptide amounts, allowing verification of equal signal response of Hi3 peptides for the proteins of interest. The generation of an intact, stable, QconCAT protein that digest completely is challenging. We have designed and analyzed five QconCAT proteins with unique design elements to address these challenges. We conclude that a suitable QconCAT protein can be produced and that the results obtained reinforce the validity of the Hi3 approach for quantifying proteins in annual influenza vaccine formulations. SIGNIFICANCE: The advances in quantitative proteomics have allowed the adaptation and application of these methods to numerous fields. In this paper we have validated a Hi3 approach to augment the antigen quantification for influenza vaccines injected into many millions annually. This methodology allows analysis of multiple antigens simultaneously without the need to generate antibodies. Key circumstances where this is advantageous are for quantitation of very similar antigens, such as the new quadravalent products and when time is critical such as in a flu pandemic.


Assuntos
Antígenos Virais/análise , Vacinas contra Influenza/imunologia , Proteômica/métodos , Cromatografia Líquida , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/normas , Proteômica/normas , Padrões de Referência , Espectrometria de Massas em Tandem , Tripsina/metabolismo
14.
J Pharm Sci ; 105(6): 1837-1842, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27238482

RESUMO

Although the impact of hydrogen peroxide (HP) on proteins in liquid solutions has been studied extensively, the impact during lyophilization has been largely overlooked. The purpose of this work was to investigate the effect of HP on lyophilized proteins and HP removal by lyophilization. A protein formulation at 5 mg/mL and its placebo were spiked with HP up to 5.0 ppm and then lyophilized. HP concentration, protein oxidation, and aggregation were monitored before and after lyophilization, as well as during storage at 25°C. The lyophilization process removed on average 94.1% of HP from protein formulation, but only 72.5% from the placebo. There were also significant increases in protein oxidization and aggregation. The oxidation increment correlated with the decrease of HP concentration in both the protein formulation and placebo at all temperatures. Protein oxidation at different freezing temperatures was also studied in follow-up studies. Data from these studies suggest that (1) HP has a significant impact on oxidation and aggregation of protein during lyophilization; (2) significant oxidation can occur even when the protein formulation is frozen; (3) the oxidized protein is more prone to aggregation during lyophilization process.


Assuntos
Química Farmacêutica/métodos , Peróxido de Hidrogênio/metabolismo , Proteínas/metabolismo , Química Farmacêutica/normas , Armazenamento de Medicamentos/métodos , Armazenamento de Medicamentos/normas , Liofilização/métodos , Liofilização/normas , Peróxido de Hidrogênio/química , Oxirredução , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Fragmentos de Peptídeos/normas , Soluções Farmacêuticas/química , Soluções Farmacêuticas/metabolismo , Soluções Farmacêuticas/normas , Projetos Piloto , Proteínas/química , Proteínas/normas
15.
Biomark Med ; 10(4): 357-65, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26974681

RESUMO

AIM: While circulating biomarkers are critical tools for cardiovascular adult care, their relevance in childhood is unknown. METHODS: We evaluated the behavior of plasma concentrations of clinically relevant cardiac biomarkers (NT-proBNP, hs-cTnI, sST2, Galectin-3) in 106 healthy children. RESULTS: Subjects were divided into age subgroups: 24 newborns (0-30 days), 26 infants (1-12 months), 30 children (1-12 years) and 26 adolescents (13-18 years). Healthy adults were used as control. NT-proBNP (newborns: 504.3 [211.07-942.7] ng/L, median [25-75 percentiles]; infants: 200.64 [76.88-306.73]; children: 97.27 [49.24-271.80]; adolescents: 24.35 [13.14-58.83]; p < 0.001) and hs-cTnI (newborns: 9.3 [3.3-93.8] ng/L; infants: 13.8 [4.82-72.52]; children: 11.45 [4.0-48.10]; adolescents: 2.6[2.07-3.90]; p < 0.001) were highest in the first month of life, showing a decline in the next years. sST2 and Galectin-3 showed no differences. CONCLUSION: Changes in hs-cTnI and NT-proBNP suggest the design of age- and sex-based reference intervals that will have to be explored in a larger population.


Assuntos
Biomarcadores/sangue , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Galectina 3/sangue , Galectina 3/normas , Voluntários Saudáveis , Humanos , Imunoensaio , Lactente , Recém-Nascido , Proteína 1 Semelhante a Receptor de Interleucina-1/sangue , Masculino , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/normas , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/normas , Valores de Referência , Troponina I/sangue , Troponina I/normas , Adulto Jovem
16.
Clin Chem Lab Med ; 54(2): 293-303, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26088062

RESUMO

BACKGROUND: The aims of this study were to establish robust reference intervals and to investigate the factors influencing bone turnover markers (BTMs) in healthy premenopausal Spanish women. METHODS: A total of 184 women (35-45 years) from 13 centers in Catalonia were analyzed. Blood and second void urine samples were collected between 8 a.m. and 10 a.m. after an overnight fast. Serum procollagen type I amino-terminal propeptide (PINP) and serum cross-linked C-terminal telopeptide of type I collagen (CTX-I) were measured by two automated assays (Roche and IDS), bone alkaline phosphatase (bone ALP) by ELISA, osteocalcin (OC) by IRMA and urinary NTX-I by ELISA. PTH and 25-hydroxyvitamin D (25OHD) levels were measured. All participants completed a questionnaire on lifestyle factors. RESULTS: Reference intervals were: PINP: 22.7-63.1 and 21.8-65.5 µg/L, bone ALP: 6.0-13.6 µg/L, OC: 8.0-23.0 µg/L, CTX-I: 137-484 and 109-544 ng/L and NTX-I: 19.6-68.9 nM/mM. Oral contraceptive pills (OCPs) influenced PINP (p=0.007), and low body mass index (BMI) was associated with higher BTMs except for bone ALP. Women under 40 had higher median values of most BTMs. CTX-I was influenced by calcium intake (p=0.010) and PTH (p=0.007). 25OHD levels did not influence BTMs. Concordance between the two automated assays for PINP and particularly CTX-I was poor. CONCLUSIONS: Robust reference intervals for BTMs in a Southern European country are provided. The effects of OCPs and BMI on their levels are significant, whilst serum 25OHD levels did not influence BTMs. Age, calcium intake, BMI and PTH influenced CTX-I. The two automated assays for measuring PINP and CTX-I are not interchangeable.


Assuntos
Biomarcadores/sangue , Remodelação Óssea , Ensaio de Imunoadsorção Enzimática , Adulto , Fosfatase Alcalina/análise , Fosfatase Alcalina/normas , Biomarcadores/urina , Índice de Massa Corporal , Colágeno Tipo I/sangue , Colágeno Tipo I/normas , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Pessoa de Meia-Idade , Osteocalcina/análise , Osteocalcina/normas , Hormônio Paratireóideo/análise , Hormônio Paratireóideo/normas , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/normas , Fragmentos de Peptídeos/urina , Peptídeos/sangue , Peptídeos/normas , Pré-Menopausa , Pró-Colágeno/sangue , Pró-Colágeno/normas , Pró-Colágeno/urina , Valores de Referência , Vitamina D/análogos & derivados , Vitamina D/análise , Vitamina D/normas
17.
J Alzheimers Dis ; 47(3): 583-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26401694

RESUMO

The aim of this study was to investigate the process of amyloidogenesis of amyloid-ß (Aß)42 peptide, by means of fluorescence spectroscopy, electron microscopy, X-ray diffraction, and mass spectrometry. It has been repeatedly reported in the literature that the process of fibril formation by Aß42 peptide depends considerably not only upon the specific conditions (ionic conditions, pH, temperature, mixing, etc.), as well as the manufacturing route (synthetic or recombinant), but also on the methods of synthesis and purification. We have, for the first time, systematically analyzed samples of Aß42 peptide supplied by five different companies (Anaspec, Invitrogen, Enzo, Sigma-Aldrich, and SynthAssist) and obtained evidence of significant variability, including lot to lot variations. All studied samples formed amyloid-like fibrils at pH3-6, and the fibrils contained cross-ß structures. Samples from Anaspec, Invitrogen, and Enzo formed one particular type of amyloid-like fibrils, while the samples from Sigma-Aldrich and SynthAssist formed another distinct type of fibrils. The observed polymorphism emphasizes the capacity of the Aß42 peptide to act as a prion agent with varying structural characteristics. The presented data have allowed us to propose a possible mechanism of formation of amyloid-like fibrils.


Assuntos
Peptídeos beta-Amiloides/química , Peptídeos beta-Amiloides/normas , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/normas , Peptídeos beta-Amiloides/genética , Peptídeos beta-Amiloides/isolamento & purificação , Peptídeos beta-Amiloides/metabolismo , Humanos , Concentração de Íons de Hidrogênio , Espectrometria de Massas , Microscopia Eletrônica , Fragmentos de Peptídeos/genética , Fragmentos de Peptídeos/isolamento & purificação , Fragmentos de Peptídeos/metabolismo , Príons/metabolismo , Multimerização Proteica , Controle de Qualidade , Proteínas Recombinantes/química , Proteínas Recombinantes/isolamento & purificação , Proteínas Recombinantes/metabolismo , Espectrometria de Fluorescência , Difração de Raios X
18.
Trends Pharmacol Sci ; 36(5): 297-309, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25840462

RESUMO

Aggregation of amyloid-ß (Aß) into oligomers, fibrils, and plaques is central in the molecular pathogenesis of Alzheimer's disease (AD), and is the main focus of AD drug development. Biomarkers to monitor Aß metabolism and aggregation directly in patients are important for further detailed study of the involvement of Aß in disease pathogenesis and to monitor the biochemical effect of drugs targeting Aß in clinical trials. Furthermore, if anti-Aß disease-modifying drugs prove to be effective clinically, amyloid biomarkers will be of special value in the clinic to identify patients with brain amyloid deposition at risk for progression to AD dementia, to enable initiation of treatment before neurodegeneration is too severe, and to monitor drug effects on Aß metabolism or pathology to guide dosage. Two types of amyloid biomarker have been developed: Aß-binding ligands for use in positron emission tomography (PET) and assays to measure Aß42 in cerebrospinal fluid (CSF). In this review, we present the rationales behind these biomarkers and compare their ability to measure Aß plaque load in the brain. We also review possible shortcomings and the need of standardization of both biomarkers, as well as their implementation in the clinic.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Fragmentos de Peptídeos/líquido cefalorraquidiano , Tomografia por Emissão de Pósitrons/normas , Doença de Alzheimer/líquido cefalorraquidiano , Peptídeos beta-Amiloides/normas , Animais , Biomarcadores/líquido cefalorraquidiano , Humanos , Fragmentos de Peptídeos/normas , Padrões de Referência
19.
AAPS J ; 17(3): 643-51, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25716148

RESUMO

A liquid chromatography-high resolution mass spectrometry (LC-HRMS) method was developed using three peptide drugs: salmon calcitonin, bivalirudin, and exenatide as model systems to assess the suitability of this approach for monitoring peptide drug product quality. Calcitonin and its related impurities displayed linear responses over the range from 0.1 to 10 µM (R (2) values for calcitonin salmon, Glu(14)-calcitonin, and acetyl-calcitonin were 0.995, 0.996, and 0.993, respectively). Intra-assay precision in terms of relative standard deviation (%RSD) was less than 10% at all tested concentrations. The accuracy of the method was greater than 85% as measured by spiking 0.1, 0.3, and 1% of Glu(14)-calcitonin and acetyl-calcitonin into a stock calcitonin solution. Limits of detection for calcitonin, Glu(14)-calcitonin, and acetyl-calcitonin were 0.02, 0.03, and 0.04 µM, respectively, indicating that an impurity present at less than 0.1% (0.1 µM) of the drug product API concentration (107 µM) could be detected. Method validation studies analyzing bivalirudin and exenatide drug products exhibited similar results to calcitonin salmon in regard to high selectivity, sensitivity, precision, and linearity. Added benefits of using LC-HRMS-based methods are the ability to also determine amino acid composition, confirm peptide sequence, and quantify impurities, even when they are co-eluting, within a single experiment. LC-HRMS represents a promising approach for the quality control of peptides including the measurement of any peptide-related impurities. While the development work performed here is focus on peptide drug products, the principles could be adapted to peptide drug substance.


Assuntos
Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Sequência de Aminoácidos , Calcitonina/análise , Calcitonina/normas , Exenatida , Hirudinas/análise , Hirudinas/normas , Limite de Detecção , Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/normas , Peptídeos/normas , Controle de Qualidade , Proteínas Recombinantes/análise , Proteínas Recombinantes/normas , Peçonhas/análise
20.
Anal Chem ; 87(2): 1097-102, 2015 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-25522095

RESUMO

Quantification by targeted proteomics has largely depended on mass spectrometry and isotope-labeled internal standards. In addition to traditionally used recombinant proteins or synthetic peptides, concatenated peptides (QconCATs) were introduced as a conceptually new source of internal standard. In the present study, we focused on assessing the length of natural flanking sequences, which surround each peptide included in QconCAT and provide for identical rates of analyte and standard digestion by trypsin. We have expressed, purified, and characterized a set of seven (15)N-labeled QconCATs that cover seven tryptic peptides from human clusterin with a length of natural flanking sequences ranging from none (+0) to six amino acid residues (+6) for each tryptic peptide. Individual QconCATs were mixed with recombinant human clusterin at a 1:1 molar ratio and digested, and the actual ratios for each combination of peptide/flanking sequence were measured with a multiple reaction monitoring assay. Data analysis suggested that natural flanking sequences shorter than +6 residues can cause a quantitative error because the random appearance of other amino acid residues in close proximity to trypsin cleavage sites has unpredictable consequences for the digestion rates of QconCATs.


Assuntos
Cromatografia Líquida/métodos , Clusterina/análise , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/normas , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massas em Tandem/métodos , Tripsina/metabolismo , Sequência de Aminoácidos , Clusterina/química , Humanos , Marcação por Isótopo , Dados de Sequência Molecular , Fragmentos de Peptídeos/análise , Proteínas Recombinantes/química , Padrões de Referência , Homologia de Sequência de Aminoácidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA