Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-22921438

RESUMO

OBJECTIVE: The purpose of this study was to examine the influence of zygomaticomaxillo-orbitalis (ZMO) fracture and its symptoms on mucociliary transport (MCT). STUDY DESIGN: The study encompassed 144 patients who sustained ZMO fracture. A saccharine test was conducted in every patient both on the side of fracture and on the unaffected side. The results were analyzed in connection with the patients' age, sex, degree of injury, method of treatment, time since fracture, and duration of surgery. RESULTS: It was shown that MCT was considerably impaired on the affected side compared with the control side. However, the degree of impairment did not vary significantly in the patients regardless of the analyzed parameters. CONCLUSIONS: ZMO fracture induces the disorder of MCT. Balloon Foley catheter in the open reduction of ZMO fracture impairs MCT. The analyzed parameters do not affect the disorders of MCT.


Assuntos
Fraturas Maxilares/metabolismo , Depuração Mucociliar/fisiologia , Mucosa/patologia , Fraturas Orbitárias/metabolismo , Fraturas Zigomáticas/metabolismo , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Masculino , Fraturas Maxilares/cirurgia , Pessoa de Meia-Idade , Fraturas Orbitárias/cirurgia , Sacarina/metabolismo , Cateterismo Urinário/efeitos adversos , Fraturas Zigomáticas/cirurgia
2.
Int J Oral Maxillofac Surg ; 33(4): 361-8, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15145039

RESUMO

In this study the reconstruction capacity of orbital wall in sheep was evaluated when poly-L/D-lactide (PLDLA96) implants were used for large blow-out defects in 18 sheep. The contralateral side, where the defects healed spontaneously, served as controls. The follow-up was 12, 16, 22 and 36 weeks. Healing was evaluated clinically, radiologically, histologically and immunohistochemically. Physiochemical properties of the implants were also studied. At first, the implants were surrounded by elastic capsules, which gradually ossified. At 36 weeks, 60% were still visible and deformed but surrounded by bone. Light microscopy revealed a low grade inflammatory reaction. Expression of Tn-c and cFn was intense throughout the study. Shear strength decreased gradually and was not measurable after 16 weeks. Crystallinity increased steadily from 1.5 to 29.30% and molecular weight decreased from 49,000 to 4186. In CT, the final bony defect was smaller in the reconstructed sides than in the controls. Based on this study it can be concluded that PLDLA96 implant provokes a local inflammation, which does not prevent bone healing. The deformation of the implant, however, indicates that this PLDLA96 plate is not suitable for orbital floor reconstruction.


Assuntos
Implantes Absorvíveis , Fraturas Orbitárias/cirurgia , Implantes Orbitários , Animais , Fibronectinas/biossíntese , Histocitoquímica , Implantes Experimentais , Teste de Materiais , Fraturas Orbitárias/diagnóstico por imagem , Fraturas Orbitárias/metabolismo , Poliésteres , Radiografia , Resistência ao Cisalhamento , Ovinos , Carneiro Doméstico , Tenascina/biossíntese , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA