Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 245
Filtrar
1.
Arq Bras Oftalmol ; 88(2): e20240029, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39319918

RESUMO

PURPOSE: To evaluate the effect of upper eyelid ptosis repairwith Muller muscle-conjunctival resection on meibomian gland function and ocular surface parameters. METHODS: Thirty-eight patients who underwent ptosis repair with Muller muscle-conjunctival resection were retrospectively reviewed. Meibomian gland loss, Ocular Surface Disease Index OXFORD score, meiboscore, and noninvasive keratograph break-up time were measured preoperatively and at 1st, 3rd, and 6th months postoperatively. RESULTS: Noninvasive keratograph break-up time values decreased significantly at 1st and 3rd months postoperatively compared to the preoperative level, but were similar to the preoperative level at 6th months postoperatively (p<0.001 and p=0.628, respectively). Ocular surface disease index, OXFORD score, meibomian gland loss, and meiboscore values increased significantly in the 1st and 3rd postoperative months compared to the preoperative period, but these values decreased to preoperative levels in the 6th postoperative month (p<0.001 and p>0.05, respectively). CONCLUSION: There is a transient deterioration in meibography findings and OSDI score in the early postoperative period afterMuller muscle-conjunctival resection. Patients undergoing Muller muscle-conjunctival resection may require topical lubricants, especially in the first 3 postoperative months.


Assuntos
Blefaroptose , Glândulas Tarsais , Humanos , Feminino , Glândulas Tarsais/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Blefaroptose/cirurgia , Adulto , Período Pós-Operatório , Resultado do Tratamento , Idoso , Fatores de Tempo , Túnica Conjuntiva/cirurgia , Túnica Conjuntiva/diagnóstico por imagem , Disfunção da Glândula Tarsal/diagnóstico por imagem , Período Pré-Operatório , Músculos Oculomotores/cirurgia , Músculos Oculomotores/diagnóstico por imagem
2.
Cornea ; 43(10): 1264-1271, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39288344

RESUMO

PURPOSE: The purpose of this study was to investigate the effects of artificial tears (AT) on the sublayers of the tear film assessed by a novel tear film imaging (TFI) device. METHODS: The mucoaqueous layer thickness (MALT) and lipid layer thickness (LLT) of 198 images from 11 healthy participants, 9 of whom had meibomian gland disease, were prospectively measured before and after exposure to 3 different AT preparations (Refresh Plus; Retaine [RTA]; Systane Complete PF [SYS]), using a novel nanometer resolution TFI device (AdOM, Israel). Participants were assessed at baseline and at 1, 5, 10, 30, and 60 minutes after instilling 1 drop of AT during 3 sessions on separate days. Repeated-measures analysis of variances were used for comparisons with P < 0.05 considered significant. RESULTS: For all ATs, the mean MALT was greatest 1 minute after drop instillation, with an increase of 67%, 55%, and 11% above the baseline for SYS, Refresh Plus, and RTA, respectively. The SYS formulation demonstrated the highest percentage increases in mean MALT and LLT at most postdrop time points. The MALT differences were significantly higher in the SYS than in the RTA ( P = 0.014). After 60 minutes, no AT group demonstrated statistically significant changes in MALT or LLT compared with baseline. CONCLUSIONS: We report, for the first time, the effects of AT on MALT and LLT using a high-resolution TFI. A substantial acute mean MALT increase occurs 1 minute after AT instillation with all agents tested, but there were clear differences in response and durability, suggesting the benefits of choosing specific AT according to the needs of each patient.


Assuntos
Lubrificantes Oftálmicos , Lágrimas , Humanos , Projetos Piloto , Lágrimas/química , Masculino , Feminino , Estudos Prospectivos , Adulto , Lubrificantes Oftálmicos/administração & dosagem , Pessoa de Meia-Idade , Adulto Jovem , Disfunção da Glândula Tarsal/diagnóstico , Glândulas Tarsais/metabolismo , Glândulas Tarsais/efeitos dos fármacos , Glândulas Tarsais/diagnóstico por imagem
3.
Arq Bras Oftalmol ; 88(1): e20230150, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109742

RESUMO

PURPOSE: To develop a simple, subjective, and reliable grading scale for isotretinoin-induced meibography changes. METHODS: After analyzing meibography images obtained from systemic isotretinoin users, a grading scale was proposed and named "meibography health score." The score ranged from 1 to 3, with decreasing gland reflectivity and identifiable margins. A total of 11 medical professionals were asked to grade 10 meibography images obtained from isotretinoin users using the proposed scale and were divided into three groups: (A) ophthalmologists with experience with meibography, (B) ophthalmologists with no experience with meibography, and (C) radiologists. The kappa statistic was determined to test interrater reliability. RESULTS: The overall kappa was approximately 0.64. The kappa scores for Groups A, B, and C were 0.78, 0.59, and 0.90, respectively. Grade 2 had the lowest kappa scores (0.62, 0.35, and 0.82 for A, B, and C, respectively) and grade 3 the highest (0.78, 0.90, and 1.0 for A, B and C, respectively). Furthermore, Group C had the highest kappa scores and Group B the lowest. CONCLUSION: The meibography health score exhibited good interrater reliability, particularly in severe cases.


Assuntos
Acne Vulgar , Fármacos Dermatológicos , Isotretinoína , Glândulas Tarsais , Variações Dependentes do Observador , Humanos , Isotretinoína/efeitos adversos , Acne Vulgar/tratamento farmacológico , Reprodutibilidade dos Testes , Glândulas Tarsais/efeitos dos fármacos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Fármacos Dermatológicos/efeitos adversos , Índice de Gravidade de Doença , Feminino , Masculino , Doenças Palpebrais/induzido quimicamente , Doenças Palpebrais/diagnóstico por imagem
4.
Surv Ophthalmol ; 69(6): 945-956, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39025239

RESUMO

Meibomian gland dysfunction (MGD) is increasingly recognized as a critical contributor to evaporative dry eye, significantly impacting visual quality. With a global prevalence estimated at 35.8 %, it presents substantial challenges for clinicians. Conventional manual evaluation techniques for MGD face limitations characterized by inefficiencies, high subjectivity, limited big data processing capabilities, and a dearth of quantitative analytical tools. With rapidly advancing artificial intelligence (AI) techniques revolutionizing ophthalmology, studies are now leveraging sophisticated AI methodologies--including computer vision, unsupervised learning, and supervised learning--to facilitate comprehensive analyses of meibomian gland (MG) evaluations. These evaluations employ various techniques, including slit lamp examination, infrared imaging, confocal microscopy, and optical coherence tomography. This paradigm shift promises enhanced accuracy and consistency in disease evaluation and severity classification. While AI has achieved preliminary strides in meibomian gland evaluation, ongoing advancements in system development and clinical validation are imperative. We review the evolution of MG evaluation, juxtapose AI-driven methods with traditional approaches, elucidate the specific roles of diverse AI technologies, and explore their practical applications using various evaluation techniques. Moreover, we delve into critical considerations for the clinical deployment of AI technologies and envisages future prospects, providing novel insights into MG evaluation and fostering technological and clinical progress in this arena.


Assuntos
Inteligência Artificial , Disfunção da Glândula Tarsal , Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Disfunção da Glândula Tarsal/diagnóstico , Tomografia de Coerência Óptica/métodos , Técnicas de Diagnóstico Oftalmológico , Microscopia Confocal/métodos
5.
BMC Ophthalmol ; 24(1): 280, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992580

RESUMO

BACKGROUND: The study aims to assess the tear film before and after phacoemulsification in patients with age-related cataracts. METHODS: A prospective observational study of 41 age-related cataract patients undergoing phacoemulsification procedure. Tear Film Break-Up Time (TBUT), Tear Film Meniscus Height (TMH), Meibomian glands (MG), and Lipid Layer Thickness (LLT) were assessed by a non-invasive Dry Eye Diagnostic System. All measurements were taken preoperatively, one week, one month, and three months postoperatively. The Marginal homogeneity and The Cochran Q tests were used in the statistical analysis. RESULTS: The value of Non-Invasive Break-Up Time (NITBUT) was statistically significantly lower at one week (7.15 ± 3.31), one month (7.61 ± 3.41), and three months (7.66 ± 3.36) postoperatively than preoperatively (10.71 ± 2.71), p < 0.001. The Non- Invasive Tear Meniscus Height (NITMH) was significantly lower at one week (0.18 ± 0.0), one month (0.20 ± 0.09), and three months (0.20 ± 0.09) postoperatively than preoperatively (0.30 ± 0.113) p < 0.001. By the first month, both (NITBUT) and (NITMH) improved significantly compared to the first post-operative week. There was no statistically significant difference between one month and three months. The (NITMH) improved to a healthy level of ≥ 0.2 mm by the first month through the third month. Both (NITBUT) and (NITMH) did not reach the baseline by the third month. The meibomian glands and the lipid layer thickness had the same preoperative grade distribution without changes. CONCLUSION: Phacoemulsification surgery can cause post-operative deterioration in the tear film, which starts within a week of the procedure, followed by gradual recovery over the next weeks and months. The phacoemulsification procedure mainly affects the tear break-up time and tear meniscus height. Both the lipid layer and meibomian glands are not affected.


Assuntos
Catarata , Facoemulsificação , Lágrimas , Humanos , Facoemulsificação/efeitos adversos , Lágrimas/metabolismo , Estudos Prospectivos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Catarata/complicações , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/metabolismo , Síndromes do Olho Seco/diagnóstico , Período Pós-Operatório , Idoso de 80 Anos ou mais , Glândulas Tarsais/metabolismo , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Período Pré-Operatório
6.
Invest Ophthalmol Vis Sci ; 65(8): 49, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39083311

RESUMO

Purpose: The purpose of this study was to investigate differences in the composition of meibum extracted from human meibomian glands displaying different morphological characteristics. Methods: Adult participants with evidence of meibomian gland shortening were enrolled. Glands were observed using infrared meibography, and meibum was collected from one short and one long gland from the lower eyelid of the same eye. Total protein concentration was evaluated using the detergent compatible (DC) protein assay and lipid analysis was performed using liquid chromatography mass spectrometry. Results: Fifteen participants (8 women and 7 men) completed the study (mean age = 34.7 ± 7.7 years). The average volume of meibum collected from the short and long glands was 0.02 ± 0.01 and 0.05 ± 0.03 µL, respectively (P = 0.01). Average protein concentration in the short glands was significantly higher compared to the long glands (0.10 ± 0.03 vs. 0.08 ± 0.02 mg/mL, P = 0.01). Among the non-polar lipids, the mole percent of cholesterol esters (CEs; P = 0.02), triacylglycerols (TAGs; P = 0.04), and ceramide (Cer; P = 0.03) was significantly lower in short glands compared with long glands. Among the polar lipids, the mole percent of (O-acyl)-ω-hydroxy fatty acid (OAHFA; P = 0.01) was significantly lower in short glands, whereas phosphatidylcholine (PC; P = 0.02) and sphingomyelin (SM; P = 0.01) were significantly higher in short glands than long glands. Conclusions: Meibum composition differed between short and long glands. The lower mole percent of CE, TAG, OAHFA, and Cer and a higher mole percent of PC and SM among short glands may indicate disease activity. This information may clarify the natural history of meibomian gland dysfunction and future targets for therapy.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/metabolismo , Glândulas Tarsais/diagnóstico por imagem , Feminino , Masculino , Adulto , Lágrimas/química , Lágrimas/metabolismo , Lipídeos/análise , Pessoa de Meia-Idade , Espectrometria de Massas , Disfunção da Glândula Tarsal/metabolismo , Cromatografia Líquida
7.
Invest Ophthalmol Vis Sci ; 65(8): 41, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39046756

RESUMO

Purpose: Understanding of the role of the tear film lipid layer (TFLL) in evaporative dry eye requires knowledge of its structure. X-ray studies show 11.1-nm thick lamellae in meibum at tear film temperature (approximately 35°C), whereas below 30°C, 4.88-nm thick lamellae predominate. Here, high resolution microscopy of meibum spread on saline is studied as a function of temperature, to compare with x-ray results. Methods: A purpose-built high resolution color microscope, previously used to study the TFLL, was used to study meibum from 10 subjects. It was spread on buffered saline at near 40°C, and allowed to cool to room temperature. Analytical methods from previous studies were applied to measure meibum and lamellar thickness. Results: Initially, an irregular "island" was formed, surrounded by a "background layer" of 7.8 ± 0.3 nm thickness. Dewetting of the meibum layer always occurred, leading to the formation of lens-shaped droplets. Below 30°C, the lenses start to emit "tails" having a multilamellar structure containing up to about 49 lamellae superimposed on the background layer, each lamella being 4.82 ± 0.13 nm thick. Conclusions: Below 30°C, meibum spread on saline shows a multilamellar structure like the 4.88 nm thickness in x-ray studies, demonstrating the ability to observe and measure tightly stacked lamellae. In contrast, above 30°C, the 11.1 nm lamellae were not observed as in x-ray studies, indicating that these lamellae were not tightly stacked but may be separated by disordered lipid. The role of these findings in evaporative dry eye is discussed.


Assuntos
Glândulas Tarsais , Lágrimas , Humanos , Glândulas Tarsais/metabolismo , Glândulas Tarsais/diagnóstico por imagem , Lágrimas/química , Solução Salina , Feminino , Adulto , Masculino , Síndromes do Olho Seco/metabolismo , Temperatura , Pessoa de Meia-Idade , Microscopia/métodos
8.
Cutan Ocul Toxicol ; 43(3): 176-181, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38873903

RESUMO

PURPOSE: The study aims to investigate changes in tear function, meibomian glands and corneal endothelium in patients receiving systemic isotretinoin therapy. MATERIALS AND METHODS: This prospective study included 38 eyes from 38 patients (23 females and 15 males) treated with systemic isotretinoin (0.5-1 mg/kg/day) following the diagnosis of acne vulgaris. All patients underwent a comprehensive ophthalmologic examination at baseline, 1st month, and third month of treatment. Subjective complaints were assessed using the Ocular Surface Disease Index (OSDI). Tear functions were evaluated through non-invasive tear break up time (NIBUT) and Schirmer I test. Meibomian gland (MG) changes were examined using meibography. Corneal parameters, including endothelial cell density (ECD), coefficient of variation (CV), the number of cells with a hexagonal shape (6A), average cell area (AVG), and central corneal thickness (CCT) were assessed using non-contact specular microscopy. RESULTS: The mean age of the patients was 19.29 ± 2.83 years. Ocular surface-related discomfort, measured with OSDI scores, significantly worsened at the third month measurements compared to the pre-treatment values (p < 0.001). In the 1st month of treatment, there was a significant decrease in NIBUT (p < 0.05). No statistically significant difference was found in the Schirmer test results at each visit. According to the 1st and third-month analysis, there was a significant increase in MG loss compared to the pre-treatment period (p < 0.001). ECD, CV, 6 A, AVG measurements at the first and third months showed a significant change compared to the pre-treatment values (p < 0.001). No significant difference was observed in the CCT measurements during the treatment. CONCLUSION: Systemic isotretinoin disrupted tear stability, caused MG loss, deterioration in corneal endothelium, and led to symptomatic complaints in patients.


Assuntos
Acne Vulgar , Fármacos Dermatológicos , Endotélio Corneano , Isotretinoína , Glândulas Tarsais , Lágrimas , Humanos , Feminino , Masculino , Isotretinoína/efeitos adversos , Isotretinoína/uso terapêutico , Isotretinoína/administração & dosagem , Endotélio Corneano/efeitos dos fármacos , Endotélio Corneano/patologia , Lágrimas/efeitos dos fármacos , Lágrimas/metabolismo , Adulto Jovem , Glândulas Tarsais/efeitos dos fármacos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Adolescente , Fármacos Dermatológicos/efeitos adversos , Fármacos Dermatológicos/administração & dosagem , Fármacos Dermatológicos/uso terapêutico , Adulto , Acne Vulgar/tratamento farmacológico , Estudos Prospectivos
9.
Transl Vis Sci Technol ; 13(6): 16, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38904611

RESUMO

Purpose: This study enhances Meibomian gland (MG) infrared image analysis in dry eye (DE) research through artificial intelligence (AI). It is comprised of two main stages: automated eyelid detection and tarsal plate segmentation to standardize meibography image analysis. The goal is to address limitations of existing assessment methods, bridge the curated and real-world dataset gap, and standardize MG image analysis. Methods: The approach involves a two-stage process: automated eyelid detection and tarsal plate segmentation. In the first stage, an AI model trained on curated data identifies relevant eyelid areas in non-curated datasets. The second stage refines the eyelid area in meibography images, enabling precise comparisons between normal and DE subjects. This approach also includes specular reflection removal and tarsal plate mask refinement. Results: The methodology achieved a promising instance-wise accuracy of 80.8% for distinguishing meibography images from 399 DE and 235 non-DE subjects. By integrating diverse datasets and refining the area of interest, this approach enhances meibography feature extraction accuracy. Dimension reduction through Uniform Manifold Approximation and Projection (UMAP) allows feature visualization, revealing distinct clusters for DE and non-DE phenotypes. Conclusions: The AI-driven methodology presented here quantifies and classifies meibography image features and standardizes the analysis process. By bootstrapping the model from curated datasets, this methodology addresses real-world dataset challenges to enhance the accuracy of meibography image feature extraction. Translational Relevance: The study presents a standardized method for meibography image analysis. This method could serve as a valuable tool in facilitating more targeted investigations into MG characteristics.


Assuntos
Inteligência Artificial , Síndromes do Olho Seco , Glândulas Tarsais , Humanos , Síndromes do Olho Seco/diagnóstico por imagem , Glândulas Tarsais/diagnóstico por imagem , Feminino , Masculino , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Adulto , Técnicas de Diagnóstico Oftalmológico/normas , Idoso , Raios Infravermelhos
10.
Transl Vis Sci Technol ; 13(6): 6, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38874976

RESUMO

Purpose: To evaluate the ability of swept-source optical coherence tomography angiography (SS-OCTA) to assess lid margin vascularity. Methods: This prospective, cross-sectional trial enrolled 125 participants, including 15 control subjects and 110 meibomian gland dysfunction (MGD) patients. Lid margin blood flow density (LMBFD) was obtained using SS-OCTA. LMBFD was assessed for repeatability in 54 of 125 participants and for reproducibility in 23 of 125 participants. The efficacy of LMBFD was validated in the 125 participants, who were divided into mild (n = 46), moderate (n = 42), and severe groups (n = 37) according to the lid margin vascularity severity shown in the slit-lamp photographs. Correlations between LMBFD and MG-related parameters, such as ocular surface disease index (OSDI), fluorescein tear break-up time (FTBUT), cornea fluorescein staining (CFS), lid margin score (LMS), and meibomian gland expressibility (ME), were analyzed in all 125 participants. Results: Repeatability and reproducibility coefficients were satisfactorily high in the scan mode with a scan area of 6 mm × 6 mm (intraclass correlation coefficient [ICC] repeatability = 0.905; ICC reproducibility = 0.986) and a scan area of 9 mm × 9 mm (ICC repeatability = 0.888; ICC reproducibility = 0.988). The LMBFD gradually increased in the mild, moderate, and severe groups (P < 0.001). LMBFD was significant correlated with OSDI (r = 0.290, P = 0.001), FTBUT (r = -0.195, P = 0.030), CFS (r = 0.352, P < 0.001), ME (r = 0.191, P = 0.033), and LMS (r = 0.370, P < 0.001). Conclusions: LMBFD may be a noninvasive, repeatable, reproducible, and efficient index for the quantitative evaluation of eyelid margin vascularity in the future. Translational Relevance: We demonstrated that SS-OCTA has the potential to evaluate the eyelid margin vascularity in MGD patients and guide future treatment strategies in clinics.


Assuntos
Pálpebras , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Masculino , Feminino , Estudos Prospectivos , Estudos Transversais , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto , Pálpebras/irrigação sanguínea , Pálpebras/diagnóstico por imagem , Idoso , Disfunção da Glândula Tarsal/diagnóstico por imagem , Fluxo Sanguíneo Regional , Angiografia/métodos , Glândulas Tarsais/diagnóstico por imagem
12.
Curr Eye Res ; 49(7): 691-697, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38717137

RESUMO

PURPOSE: The study aimed to investigate the factors associated with anterior location of Marx's line in ocular surface and living habits, especially in tear film. MATERIALS AND METHODS: This cross-sectional study enlisted 483 participants with meibomian gland dysfunction, who were divided into two groups: 160 participants with mild anterior location of Marx's line and 323 participants with moderate-to-severe anterior location. Participants completed a survey of demographic characteristics (sex, age, length of visual terminal use, sleep duration, skin property), and the Ocular Surface Disease Index and Standard Patient Evaluation of Eye Dryness questionnaires. They also underwent slit-lamp examinations of the lids, and measurements of non-invasive tear break up time, tear meniscus height, fluorescein tear break up time, lipid layer thickness, partial blink rate, lid wiper epitheliopathy, and meibomian gland dropout. RESULTS: The tear meniscus height (mild:0.21(0.18-0.25), moderate-to-severe:0.19(0.16-0.23), p = 0.004), fluorescein tear break up time(mild:3(2-4),moderate to severe:2(1-3), p = 0.000), max LLT(mild:87(62-100), moderate-to-severe:99(69-100), p = 0.04), average LLT(mild:64.5(47.5-96.75), moderate-to-severe:74(53-100), p = 0.012), min LLT(mild:52(38-75), moderate-to-severe:59(41-85), p = 0.029) differed significantly between mild and moderate-to-severe anterior location of Marx's line, and associated to the anterior location of Marx's line(r=-0.134, p = 0.03; r=-0.194, p = 0.000; r = 0.093, p = 0.041; r = 0.119, p = 0.009; r = 0.105, p = 0.022) However, no statistical significance was observed in the OSDI, SPEED, partial blink rate, non-invasive tear breakup time, lipid layer thickness, meibomian gland dropout and lid wiper epitheliopathy(p > 0.05). Meanwhile, in the demographic characteristics, statistically significant correlations were associated with skin property(r = 0.154, p = 0.001) and sleep duration(r=-0.124, p = 0.006), but not with age, sex, and the length of visual terminal use (p > 0.05). CONCLUSIONS: Lower TMH and shorter TBUT positively correlated with anterior location of the Marx's line, and were risk factors. Meanwhile, participants with oily skin and shorter sleep duration were more likely to exhibit anterior location of Marx's line.


Assuntos
Disfunção da Glândula Tarsal , Glândulas Tarsais , Lágrimas , Humanos , Estudos Transversais , Masculino , Feminino , Lágrimas/metabolismo , Lágrimas/fisiologia , Pessoa de Meia-Idade , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/metabolismo , Glândulas Tarsais/patologia , Adulto , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/metabolismo , Disfunção da Glândula Tarsal/fisiopatologia , Inquéritos e Questionários , Piscadela/fisiologia , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/metabolismo , Síndromes do Olho Seco/fisiopatologia , Idoso , Fatores de Risco
13.
Ophthalmic Plast Reconstr Surg ; 40(3): 352-355, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38722779

RESUMO

PURPOSE: Congenital distichiasis is managed either by ablation, using laser, cryotherapy, or electroepilation, or by surgical excision with mucous membrane grafting. Ablative procedures are usually blind as the exact depth of distichiatic eyelashes is unknown. The described surgical technique utilizes meibography for imaging the root and depth of distichiatic eyelashes that aided in performing electroepilation. METHODS: Six patients (n = 24 eyelids; mean age 15.5 ± 12.2 years) underwent infrared meibography (Oculus Keratograph 5 M) and noninvasive tear breakup time prospectively. Eyelashes were electroepilated using a premarked needle inserted at a depth based on meibography findings in 4 patients. Surgical success was defined as no distichiatic eyelash regrowth and functional success was defined as the resolution of symptoms at a minimum of 3 months of follow-up. RESULTS: All 6 patients had all 4 eyelids involved to varying degrees, with a total of 230 distichiatic eyelashes. The median number of distichiatic eyelashes was 9 in the upper eyelids and 4.5 in the lower eyelids. Meibography revealed visible distichiatic eyelash roots in 70% of eyelashes in the upper eyelid and 87.8% in the lower eyelid, respectively. The median eyelash root depth was 2.7 mm (mean 2.9 mm, range 1.8-5.4 mm). The mean noninvasive tear breakup time was 12.2 seconds despite absent or rudimentary meibomian gland segments seen on meibography. The anatomical success was 75% (12/16 eyelids), and functional success was 87.5% (7/8 eyes) at a median follow-up of 5.5 months. CONCLUSION: Preoperative infrared meibography in eyelids with congenital distichiasis helps estimate the eyelash depth and can be used to guide eyelash ablation procedures.


Assuntos
Pestanas , Glândulas Tarsais , Humanos , Feminino , Masculino , Pestanas/anormalidades , Adolescente , Adulto , Criança , Glândulas Tarsais/diagnóstico por imagem , Adulto Jovem , Estudos Prospectivos , Lágrimas/metabolismo , Lágrimas/fisiologia , Eletrocirurgia/métodos , Doenças Palpebrais/cirurgia , Doenças Palpebrais/diagnóstico , Doenças Palpebrais/congênito
14.
J Cataract Refract Surg ; 50(8): 868-875, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758201

RESUMO

The eyelid margin is vital to ocular surface integrity. Much peer-reviewed literature has been established in eyelid margin inflammation, better known as blepharitis. The purpose was to review and understand the impact of eyelid margin disease. Anterior blepharitis causes inflammation at the eyelash base, ciliary follicles, and the palpebral skin. Posterior blepharitis occurs when there is inflammation with the posterior eyelid margin disease. In common usage, the term "blepharitis" used alone almost always refers to anterior blepharitis. Classification of eyelid margin disease should be based on etiopathogenesis, location, primary vs secondary, and chronicity. Blepharitis has several etiopathologies (infectious, inflammatory, and squamous). Meibomian gland dysfunction (MGD) can refer to the functional and/or structural problems with the meibomian gland. Meibomitis (or meibomianitis) occurs when there is inflammation associated with the MGD. The presence of blepharitis and/or MGD (with or without inflammation) can affect the ocular surface and thereby affect anterior segment and cataract surgeries. This review article evaluates the differential diagnoses of eyelid margin disease, including various forms of blepharitis, MGD, and meibomitis.


Assuntos
Blefarite , Humanos , Blefarite/diagnóstico , Glândulas Tarsais/patologia , Glândulas Tarsais/diagnóstico por imagem , Doenças Palpebrais/diagnóstico , Pálpebras/patologia , Disfunção da Glândula Tarsal/diagnóstico , Diagnóstico Diferencial
15.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38708449

RESUMO

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Assuntos
Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/anatomia & histologia , Projetos Piloto , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Idoso , Disfunção da Glândula Tarsal/diagnóstico , Disfunção da Glândula Tarsal/diagnóstico por imagem , Lágrimas/fisiologia , Ritmo Circadiano/fisiologia , Fatores de Tempo
16.
BMJ Open Ophthalmol ; 9(1)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609325

RESUMO

OBJECTIVE: The objective of this study is to determine the validity and reliability of the red filter meibography by smartphone compared with infrared in assessing meibomian gland drop-out. METHODS AND ANALYSIS: An analytical cross-sectional study was done with a total of 35 subjects (68 eyes) with suspected MGD based on symptoms and lid morphological abnormalities. Meibomian glands were photographed using two smartphones (Samsung S9 and iPhone XR) on a slit-lamp with added red filter. Images were assessed subjectively using meiboscore by the two raters and drop-out percentages were assessed by ImageJ. RESULTS: There was no agreement in meiboscore and a minimal level of agreement in drop-out percentages between red filter meibography and infrared. Inter-rater reliability showed no agreement between two raters. Intra-rater reliability demonstrated weak agreement in rater 1 and no agreement in rater 2. CONCLUSION: Validity of the red filter meibography technique by smartphones is not yet satisfactory in evaluating drop-out. Further improvement on qualities of images must be done and research on subjective assessment was deemed necessary due to poor results of intrarater and inter-rater reliability.


Assuntos
Disfunção da Glândula Tarsal , Humanos , Smartphone , Estudos Transversais , Reprodutibilidade dos Testes , Glândulas Tarsais/diagnóstico por imagem
17.
Cont Lens Anterior Eye ; 47(3): 102162, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38565442

RESUMO

PURPOSE: To investigate if there is a visible difference in meibomian gland (MG) length between images captured with the Visante optical coherence tomography (OCT; wavelength = 1,310 nm) and the OCULUS Keratograph 5M (K5M; wavelength = 880 nm). METHODS: Adults between 18 and 40 years were recruited. Baseline dry eye disease was evaluated with the Standard Patient Evaluation of Eye Dryness (SPEED) and tear meniscus height and tear breakup time with the K5M. Right upper and lower eyelid MGs were imaged with the K5M and Visante OCT. Each image was graded with the 0 to 3 meiboscore scale. The central 5 MGs were evaluated with ImageJ for percent gland length visibility. RESULTS: Thirty participants were analyzed with a median (interquartile range [IQR]) age of 23.0 (5.0) years (53.3 % female). Overall, participants were asymptomatic and had normal tear films. Meiboscores based on K5M and Visante OCT was significantly different for the lower eyelid (0[1] vs 1[2]; p = 0.007) but not the upper eyelid (0[1] vs 0[1]; p = 1.00). The mean percent gland visibility of the upper eyelid (82.7[9.6] vs 75.2[13.5]; p < 0.001) and the lower eyelid (81.2[12.7] vs 64.1[17.6]; p < 0.001) were significantly greater on the Visante OCT than the K5M images, respectively. CONCLUSION: OCT images had significantly greater percent visible MG lengths than the K5M images. This suggests viable segments of the MGs may be missed with typical imaging, which may explain how it is possible that studies have found less post-treatment MG atrophy.


Assuntos
Síndromes do Olho Seco , Glândulas Tarsais , Lágrimas , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Feminino , Masculino , Adulto , Síndromes do Olho Seco/diagnóstico por imagem , Síndromes do Olho Seco/diagnóstico , Adulto Jovem , Lágrimas/química , Adolescente , Reprodutibilidade dos Testes
18.
Graefes Arch Clin Exp Ophthalmol ; 262(8): 2551-2560, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38502350

RESUMO

PURPOSE: To quantitatively evaluate the morphological parameters of meibomian glands (MGs) and lipid layer thickness (LLT) in patients with keratoconus (KC). METHODS: In this prospective, cross-sectional study, 164 eyes of 164 keratoconus patients and 64 eyes of 64 age-matched control subjects were included. An advanced automatic MG analyzer was used to quantitatively measure the morphological and functional parameters of MGs. Morphological and functional parameters of MGs, LLT, and other ocular surface parameters were compared between the control and KC groups. RESULTS: The mean meibomian gland diameter, length, square, and gland area ratio (GA) were all significantly decreased in the KC group (all P < 0.05), while no significant difference was observed in the gland tortuosity index (TI) and gland signal index (SI) between the KC and control groups (all P > 0.05). There was no significant difference in the number of total and incomplete blinking among patients with different stages of keratoconus (all P > 0.05). The gland diameter, square, and TI were all negatively associated with KC severity (all P < 0.05), while no significant difference was observed among all stages of KC in gland length, GA, and SI (all P > 0.05). Moreover, the LLTs were positively correlated with the gland diameter, square, GA, and TI and negatively correlated with anterior corneal curvature or KC severity (all P < 0.05). CONCLUSIONS: Atrophic morphological changes in the meibomian glands were closely correlated with the severity of keratoconus. Gland diameter may be a sensitive functional morphology metric of meibomian glands in patients with keratoconus.


Assuntos
Ceratocone , Glândulas Tarsais , Lágrimas , Humanos , Ceratocone/diagnóstico , Ceratocone/fisiopatologia , Ceratocone/metabolismo , Glândulas Tarsais/patologia , Glândulas Tarsais/metabolismo , Glândulas Tarsais/fisiopatologia , Glândulas Tarsais/diagnóstico por imagem , Masculino , Estudos Transversais , Feminino , Estudos Prospectivos , Adulto , Lágrimas/metabolismo , Adulto Jovem , Lipídeos , Córnea/patologia , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Pessoa de Meia-Idade , Adolescente , Piscadela/fisiologia
19.
Int Ophthalmol ; 44(1): 124, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38430354

RESUMO

PURPOSE: Euthyroid Graves' ophthalmology (EGO) refers to the subgroup of thyroid eye disease patients with distinct clinical presentations. This study evaluated the ocular surface and meibomian gland changes in EGO patients. METHODS: A cross-sectional study was conducted at The Chinese University of Hong Kong including 34 EGO patients and 34 age-and sex- matched healthy controls. Outcome measures include anterior segment examination, keratographic and meibographic imaging. RESULTS: Between 34 EGO patients and 34 age and sex-matched healthy controls, EGO was associated with a higher ocular surface disease index (P < 0.01), higher severity of meibomian gland dropout (upper: P < 0.001, lower: P < 0.00001) and higher percentage of partial blinking (P = 0.0036). The worse affected eyes of the EGO patients were associated with corneal staining (P = 0.0019), eyelid telangiectasia (P = 0.0009), eyelid thickening (P = 0.0013), eyelid irregularity (P = 0.0054), meibomian gland plugging (P < 0.00001), expressibility (P < 0.00001), and meibum quality (P < 0.00001). When the two eyes of the same EGO patient were compared, the degree of meibomian gland dropout was higher among the worse affected eyes (upper: P < 0.00001, and lower: P < 0.00001). Tear meniscus height, lipid layer thickness, and noninvasive break-up time were comparable between the two eyes of EGO patients and also between EGO patients and healthy controls. TMH was positively correlated with the degree of exophthalmos (r = 0.383, P < 0.05). CONCLUSION: EGO patients have more ocular surface complications and meibomian gland dropouts than healthy controls. Almost 60% of them had dry eye symptoms, but aqueous deficiency was not apparent. Further studies are warranted to clarify the mechanism of dry eye in EGO. (249 words).


Assuntos
Síndromes do Olho Seco , Glândulas Tarsais , Humanos , Glândulas Tarsais/diagnóstico por imagem , Estudos Transversais , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Piscadela , Lágrimas
20.
Indian J Ophthalmol ; 72(Suppl 4): S669-S675, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38389244

RESUMO

PURPOSE: Dry eye syndrome (DES) is a familiar sequelae of radiation therapy (RT) for head and neck cancers (HNC). Ocular surface changes such as DES occur due to injury to the conjunctival epithelium, goblet cells, corneal surface, lacrimal glands, and meibomian glands. This study aimed at the evaluation and early detection of changes in ocular surface parameters in patients receiving RT for extraocular HNC. METHODS: Forty-two eyes of 21 patients undergoing HNC RT were evaluated. Radiation technique and dose of radiation to the lens and eye were recorded. Subjects were evaluated for meibomian gland changes by meiboscore grading, ocular surface disease index (OSDI) questionnaire, Schirmer's test, tear film break-up time (TBUT), and slit-lamp examination before RT, immediately post RT, and 6 weeks post RT. A comparison of the ipsilateral eye on the irradiated side to the contralateral eye was done. RESULTS: A significant reduction in TBUT was seen immediately post RT and 6 weeks post RT ( P < 0.001 and 0.008, respectively), with an increase in meiboscore at both visits ( P < 0.001). An OSDI score of >13 was seen in 23.80% of patients post RT, with a significant difference from baseline ( P < 0.001). On comparing ipsilateral and contralateral eye groups, a significant difference from baseline was seen in TBUT ( P < 0.001 and 0.033, respectively) and meiboscore ( P < 0.001 for both eyes). A significant change of >1 second in TBUT and >1.7 in meiboscore was seen with a mean dose of around 8 Gy to the lens. CONCLUSION: All patients undergoing HNC RT should be followed up for ocular surface and meibomian gland changes. The contralateral eye should also be evaluated. Patients receiving lower doses to the ocular structures should also be kept under follow-up.


Assuntos
Síndromes do Olho Seco , Neoplasias de Cabeça e Pescoço , Glândulas Tarsais , Lágrimas , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/diagnóstico , Neoplasias de Cabeça e Pescoço/radioterapia , Glândulas Tarsais/efeitos da radiação , Glândulas Tarsais/diagnóstico por imagem , Glândulas Tarsais/patologia , Lágrimas/metabolismo , Idoso , Seguimentos , Adulto , Lesões por Radiação/diagnóstico , Lesões por Radiação/etiologia , Estudos Prospectivos , Inquéritos e Questionários , Córnea/efeitos da radiação , Córnea/patologia , Microscopia com Lâmpada de Fenda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA