Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.521
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Transl Vis Sci Technol ; 13(5): 10, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38743410

RESUMO

Purpose: To compare perimetric outcomes of an iPad perimetry app (Melbourne Rapid Fields [MRF]) with those of the Humphrey Field Analyser (HFA) testing children with glaucoma. Methods: Sixteen children diagnosed and treated for glaucoma were recruited to evaluate their perimetric performance over two visits. At each visit, they undertook visual field assessment using the MRF application as well as the HFA. The HFA test was part of their usual clinical work up and a clinical assistant judged which test format (24-2 SITA standard or SITA fast) might be suited to the testing of that child. The primary outcome measure was the association and repeatability of mean deviation (MD) for the MRF and HFA tests, by way of regression, intraclass correlation coefficient and Bland-Altman analysis. Secondary measures were comparisons of pattern deviation indices, test times as well as an indication of participant test preference. Summary data show means ± standard deviation. Results: The age for our cohort was 7 to 15 years of age (mean, 10.0 ± 2.4 years of age). The MRF MD was in close concordance to HFA MD with an intraclass correlation coefficient of 0.91 (95% confidence interval, 0.82-0.95). Bland-Altman analysis found little bias (-0.6 dB) and a 95% coefficient of repeatability of 2.1 dB in eyes having a normal HFA MD. In eyes with glaucomatous visual field defects the 95% coefficient of repeatability at retest was much larger for both the MRF (10.5 dB) as well as for the HFA (10.0 dB). Average MRF test times (5.6 ± 1.2 minutes) were similar to SITA Fast (5.4 ± 1.9 minutes) with both being significantly faster than SITA standard (8.6 ± 1.4 minutes; P < 0.001). All children chose testing with the MRF as their preference. Conclusions: MRF correlated strongly with HFA and was preferred by the children over the HFA. MRF is suitable for perimetric evaluation of children with glaucoma. Translational Relevance: This study finds that an iPad based visual field test can be used with children having glaucoma to yield outcomes similar to SITA-fast. Children indicate a preference for such testing.


Assuntos
Computadores de Mão , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Criança , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Testes de Campo Visual/instrumentação , Masculino , Feminino , Adolescente , Glaucoma/diagnóstico , Glaucoma/fisiopatologia , Reprodutibilidade dos Testes
2.
BMC Med Inform Decis Mak ; 24(1): 115, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698412

RESUMO

BACKGROUND: Glaucoma, the second leading cause of global blindness, demands timely detection due to its asymptomatic progression. This paper introduces an advanced computerized system, integrates Machine Learning (ML), convolutional neural networks (CNNs), and image processing for accurate glaucoma detection using medical imaging data, surpassing prior research efforts. METHOD: Developing a hybrid glaucoma detection framework using CNNs (ResNet50, VGG-16) and Random Forest. Models analyze pre-processed retinal images independently, and post-processing rules combine predictions for an overall glaucoma impact assessment. RESULT: The hybrid framework achieves a significant 95.41% accuracy, with precision and recall at 99.37% and 88.37%, respectively. The F1 score, balancing precision and recall, reaches a commendable 93.52%. These results highlight the robustness and effectiveness of the hybrid framework in accurate glaucoma diagnosis. CONCLUSION: In summary, our research presents an innovative hybrid framework combining CNNs and traditional ML models for glaucoma detection. Using ResNet50, VGG-16, and Random Forest in an ensemble approach yields remarkable accuracy, precision, recall, and F1 score. These results showcase the methodology's potential to enhance glaucoma diagnosis, emphasizing its promising role in early detection and preventing irreversible vision loss. The integration of ML and DNNs in medical imaging analysis suggests a valuable path for future advancements in ophthalmic healthcare.


Assuntos
Aprendizado Profundo , Glaucoma , Aprendizado de Máquina , Humanos , Glaucoma/diagnóstico por imagem , Glaucoma/diagnóstico , Redes Neurais de Computação
3.
Sci Rep ; 14(1): 10306, 2024 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-38705883

RESUMO

Multiple ophthalmic diseases lead to decreased capillary perfusion that can be visualized using optical coherence tomography angiography images. To quantify the decrease in perfusion, past studies have often used the vessel density, which is the percentage of vessel pixels in the image. However, this method is often not sensitive enough to detect subtle changes in early pathology. More recent methods are based on quantifying non-perfused or intercapillary areas between the vessels. These methods rely upon the accuracy of vessel segmentation, which is a challenging task and therefore a limiting factor for reliability. Intercapillary areas computed from perfusion-distance measures are less sensitive to errors in the vessel segmentation since the distance to the next vessel is only slightly changing if gaps are present in the segmentation. We present a novel method for distinguishing between glaucoma patients and healthy controls based on features computed from the probability density function of these perfusion-distance areas. The proposed approach is evaluated on different capillary plexuses and outperforms previously proposed methods that use handcrafted features for classification. Moreover the results of the proposed method are in the same range as the ones of convolutional neural networks trained on the raw input images and is therefore a computationally efficient, simple to implement and explainable alternative to deep learning-based approaches.


Assuntos
Glaucoma , Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Glaucoma/diagnóstico por imagem , Glaucoma/diagnóstico , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Feminino , Masculino , Pessoa de Meia-Idade , Processamento de Imagem Assistida por Computador/métodos , Capilares/diagnóstico por imagem , Capilares/patologia
4.
Zhonghua Yan Ke Za Zhi ; 60(5): 458-466, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706086

RESUMO

Childhood glaucoma is a disease that seriously endangers children's visual health. It will accompany the patients throughout their lives and bring a heavy burden to families and society. Most childhood blindness caused by glaucoma is preventable or treatable. Relevant research has made progress in recent years. Based on the new consensus reached by the World Glaucoma Association and the latest medical evidence at home and abroad, this article summarizes the definition, classification, diagnosis, molecular genetics, pathogenesis and comprehensive treatments including drugs and surgery of childhood glaucoma, with a focus on the application of various surgical methods, so as to provide reference for clinical and scientific research and improve the clinical diagnosis and treatment of childhood glaucoma.


Assuntos
Glaucoma , Humanos , Glaucoma/diagnóstico , Glaucoma/terapia , Criança
5.
BMC Genomics ; 25(1): 484, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755526

RESUMO

Childhood glaucoma (CG) encompasses a heterogeneous group of genetic eye disorders that is responsible for approximately 5% of childhood blindness worldwide. Understanding the molecular aetiology is key to improving diagnosis, prognosis and unlocking the potential for optimising clinical management. In this study, we investigated 86 CG cases from 78 unrelated families of diverse ethnic backgrounds, recruited into the Genomics England 100,000 Genomes Project (GE100KGP) rare disease cohort, to improve the genetic diagnostic yield. Using the Genomics England/Genomic Medicine Centres (GE/GMC) diagnostic pipeline, 13 unrelated families were solved (13/78, 17%). Further interrogation using an expanded gene panel yielded a molecular diagnosis in 7 more unrelated families (7/78, 9%). This analysis effectively raises the total number of solved CG families in the GE100KGP to 26% (20/78 families). Twenty-five percent (5/20) of the solved families had primary congenital glaucoma (PCG), while 75% (15/20) had secondary CG; 53% of this group had non-acquired ocular anomalies (including iris hypoplasia, megalocornea, ectopia pupillae, retinal dystrophy, and refractive errors) and 47% had non-acquired systemic diseases such as cardiac abnormalities, hearing impairment, and developmental delay. CYP1B1 was the most frequently implicated gene, accounting for 55% (11/20) of the solved families. We identified two novel likely pathogenic variants in the TEK gene, in addition to one novel pathogenic copy number variant (CNV) in FOXC1. Variants that passed undetected in the GE100KGP diagnostic pipeline were likely due to limitations of the tiering process, the use of smaller gene panels during analysis, and the prioritisation of coding SNVs and indels over larger structural variants, CNVs, and non-coding variants.


Assuntos
Glaucoma , Humanos , Glaucoma/genética , Glaucoma/diagnóstico , Masculino , Feminino , Criança , Pré-Escolar , Citocromo P-450 CYP1B1/genética , Mutação , Lactente , Genômica/métodos , Linhagem , Adolescente , Fatores de Transcrição Forkhead
6.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739130

RESUMO

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Assuntos
Córnea , Topografia da Córnea , Glaucoma , Pressão Intraocular , Tonometria Ocular , Humanos , Tonometria Ocular/métodos , Córnea/diagnóstico por imagem , Pressão Intraocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Topografia da Córnea/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Reprodutibilidade dos Testes , Idoso , Adulto
7.
Vestn Oftalmol ; 140(2. Vyp. 2): 34-42, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739129

RESUMO

PURPOSE: This study analyzes changes in light sensitivity in each test point of the visual field in patients with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study were analyzed. All patients underwent assessment of retinal light sensitivity and its variability in 54 points corresponding to the 24-2 program. Mean light sensitivity values were calculated in each point. Intergroup analysis was performed to evaluate changes in light sensitivity in each point. RESULTS: The range of light sensitivity decrease in the early glaucoma group compared to the control group was from 1.5 to 3.6 dB. The range of light sensitivity decrease in the moderate glaucoma group compared to the control group was from 2.1 to 11.5 dB, and compared to the early glaucoma group - from -0.9 to 7.9 dB. The most frequent decrease in light sensitivity was detected in the nasal sector and along the horizontal line in the upper half of the visual field. This trend persisted within the central 10 degrees of the visual field. The range of light sensitivity decrease in the advanced glaucoma group compared to the control group was from 14.1 to 28.0 dB, and compared to the early glaucoma group - from 11.35 to 26.08 dB, compared to the moderate glaucoma group - from 9.1 to 23.5 dB. The most frequent and severe decrease in light sensitivity was detected in the paracentral zone in the lower half of the visual field. CONCLUSION: The study analyzed the trends in the development of glaucoma from the early to the advanced stage. The most frequent and severe defect in light sensitivity in cases of verified advanced glaucoma was found in the lower half of the visual field. Points No. 32, 33 and 40 can be indicated as the area of interest in assessing the progression of glaucoma, as they were found to have the most profound changes in light sensitivity as glaucoma progressed.


Assuntos
Progressão da Doença , Glaucoma , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Masculino , Feminino , Pessoa de Meia-Idade , Testes de Campo Visual/métodos , Estudos Prospectivos , Idoso , Estudos de Casos e Controles , Luz
8.
Vestn Oftalmol ; 140(2. Vyp. 2): 116-122, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739140

RESUMO

PURPOSE: This study assesses the light sensitivity and its variability in each point of the visual field in patients without glaucoma and with different stages of glaucoma. MATERIAL AND METHODS: The data of a prospective analytical case-control study involving 500 patients were analyzed. The initial examination of all patients was performed using basic ophthalmological methods, including static perimetry. Retinal light sensitivity and its variability were assessed in 54 points corresponding to the Humphrey 24-2 program. Mean deviation and pattern standard deviation of light sensitivity were calculated for each point. RESULTS: The lowest light sensitivity values in patients with moderate glaucoma were found in the periphery of the nasal sector, at point No. 27 - 14.4 dB, and at points No. 24-26 along the horizontal axis from the nasal side - from 17.7 to 22.7 dB. The maximum variability of light sensitivity was found in the nasal sector on both sides of the horizontal line - from 10.7 to 11.5 dB. The average light sensitivity above the horizontal axis in patients with advanced glaucoma was 10.8 dB, which is 2 dB higher than in the lower half of the visual field - 8.8 dB. The highest light sensitivity values were found at points No. 24 - 17.7 dB and No. 31 - 16.78 dB, the lowest - at point No. 32 - 4.5 dB. The average variability values of light sensitivity in the upper half of the visual field were 9.6 dB, which is 1 dB less than in the lower half of the visual field - 10.6 dB. CONCLUSION: According to our data, points No. 32 and No. 40 are of particular interest in the diagnostic plan. In these loci, the highest light sensitivity values were determined in early and moderate glaucoma. However, the values in these points decrease significantly in advanced glaucoma. It can be assumed that changes in light sensitivity in these loci at the early stages of glaucoma may be a predictor of glaucoma progression.


Assuntos
Glaucoma , Retina , Testes de Campo Visual , Campos Visuais , Humanos , Campos Visuais/fisiologia , Testes de Campo Visual/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Pessoa de Meia-Idade , Masculino , Feminino , Retina/fisiopatologia , Estudos Prospectivos , Adulto , Luz , Idoso , Limiar Sensorial/fisiologia , Estudos de Casos e Controles , Reprodutibilidade dos Testes
9.
Transl Vis Sci Technol ; 13(4): 2, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564202

RESUMO

Purpose: Prior evidence suggests racial disparities in the utilization of visual field testing (VFT) for the diagnosis and monitoring of glaucoma. In this study, we considered the effect of baseline glaucoma severity and socioeconomic disadvantage along with other potential confounders such as test reliability, ancillary tests, and glaucoma surgeries on racial disparity in the frequency of VFT. Methods: The records of all subjects with a diagnosis of glaucoma who received VFT at an academic, tertiary care facility from January 2018 to December 2021 were accessed. Analysis was performed to compare VFT frequency, the total number of office visits (DoS), and the ratio of VFT frequency to DoS (VFT/DoS) across self-reported races while controlling for sex, age, socioeconomic disadvantage (Area Deprivation Index), VF reliability indicators and baseline mean deviation, optical coherence tomography frequency, and glaucoma surgeries. Results: Among the 2654 subjects (1515 White, 782 Black, and 357 Asian) included in this study, Black subjects had the worst socioeconomic status and disease severity at baseline. They also experienced a 3% lower VFT/DoS ratio compared to White subjects (P = 0.031). Asian subjects had a 5% lower VFT/DoS ratio compared to White subjects (P = 0.015). Discussion: We identified racial disparity in performing VFT in subjects with glaucoma even when multiple confounders were considered. Further investigation is necessary to identify other race-associated factors to work toward reducing racial disparities in VFT. Translational Relevance: Black and Asian subjects with glaucoma receive fewer VFT per visit compared to White subjects even when considering socioeconomic disadvantage and disease severity.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Asiático , Glaucoma/diagnóstico , Tomografia de Coerência Óptica
10.
Rom J Ophthalmol ; 68(1): 60-64, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617728

RESUMO

Aim: To present a complex case of Ahmed tube exposure 6 months after the implantation associated with corneal melting and iris prolapse, and the surgical reposition that required multiple allografts and limbal reconstruction. Methods: A 60-year-old patient arrived at the emergency room with tube exposure combined with corneal melting and iris prolapse from a previously placed Ahmed valve 6 months prior. Our approach was to use one corneoscleral graft to repair the melted cornea and avoid further iris prolapse and a second scleral graft to cover the repositioned tube. Upon completion of conjunctival dissection, cleaning and deepithelization of the melted cornea and the tube by application of alcohol 100% followed. A new entry point was made for the tube and was covered using an alcohol-preserved scleral allograft and the previous entry point was repaired using a corneoscleral allograft with the corneal aspect restoring the limbus and avoiding further iris protrusion. Results: 6 months follow-up of the patient showed excellent recovery, anatomical restoration, and IOP normalization. Conclusion: Surgical repair of these cases can be very demanding, and requires surgical improvisation and prolonged surgical time. The literature remains very limited on how a surgeon should approach similar cases, which are the crucial tips, and which are the missteps that should be avoided. In this case, we used multiple scleral/corneoscleral allografts in a specific orientation and different sutures to reconstruct the damaged limbal area and restore the anatomy. Abbreviations: VA = Visual Acuity, GDD = Glaucoma Drainage Device, IOP = Intra Ocular Pressure.


Assuntos
Úlcera da Córnea , Glaucoma , Humanos , Pessoa de Meia-Idade , Glaucoma/complicações , Glaucoma/diagnóstico , Córnea , Iris , Etanol , Aloenxertos
11.
Int Ophthalmol ; 44(1): 186, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643220

RESUMO

PURPOSE: This study introduces the Order of Magnitude (OM), a cost-effective, indigenous, virtual reality-based visual field analyzer designed for detecting glaucomatous visual field loss. METHODS: The OM test employs a two-step supra-thresholding algorithm utilizing stimuli of 0.43°diameter (equivalent to Goldmann size III) at low and high thresholds. A comparative analysis was conducted against the Humphrey visual field (HVF) test, considered the gold standard in clinical practice. Participants, including those with glaucoma and normal individuals, underwent comprehensive eye examinations alongside the OM and HVF tests between April and October 2019. Diagnostic sensitivity and specificity of the OM test were assessed against clinical diagnoses made by specialists. RESULTS: We studied 157 eyes (74 glaucomatous, 83 control) of 152 participants. Results demonstrated a high level of reliability for both OM and HVF tests, with no significant difference observed (P = 0.19, Chi-square test). The sensitivity and specificity of the OM test were found to be 93% (95% CI 86-100%) and 83% (95% CI 72.4-93%), respectively, while the HVF test showed sensitivity and specificity of 98% (95% CI 93.9-100%) and 83% (95% CI 73.9-92.8%), respectively. CONCLUSION: These findings suggest that the OM test is non-inferior to the reference standard HVF test in identifying glaucomatous visual field loss.


Assuntos
Glaucoma , Campos Visuais , Humanos , Reprodutibilidade dos Testes , Glaucoma/diagnóstico , Testes de Campo Visual/métodos , Transtornos da Visão/diagnóstico , Sensibilidade e Especificidade
12.
Transl Vis Sci Technol ; 13(4): 10, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38578635

RESUMO

Purpose: This study aims to determine whether OCT-derived rates of change in minimum rim width (MRW) are associated with and can potentially predict corresponding alterations in retinal nerve fiber layer thickness (RNFLT) in people with glaucoma. Methods: The rates of change between six-monthly visits were taken from 568 eyes of 278 participants in the P3 Study. Structural equation models (SEM) assessed whether one parameter was predicted by the concurrent or previous rate of the other parameter, after adjusting for its own rate in the previous time interval. Root mean square error of approximation (RMSEA, with 90% confidence intervals [CI]), Tucker Lewis index (TLI) and the comparative fit index (CFI) assessed goodness of fit. Results: Models without a time lag provided a better fit for the data (RMSEA = 0.101 [CI, 0.089, 0.113]), compared to a model featuring a time lag in RNFLT (RMSEA = 0.114 [CI, 0.102, 0.126]) or MRW (RMSEA = 0.114 [CI, 0.102, 0.127]). The SEMs indicated that rates for both MRW and RNFLT were predicted by their own rate in the previous time interval and by the other measure's change in the concurrent time interval (P > 0.001 for all). No evidence of a clinically significant time lag for either parameter was determined. Conclusions: MRW and RNFLT exhibit concurrent changes over time in patients with glaucoma, with no clinically significant time lag determined. Translational Relevance: RNFLT may be more useful than MRW in early glaucoma assessment because of its previously reported lower variability and reduced sensitivity to intraocular pressure changes.


Assuntos
Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagem , Células Ganglionares da Retina , Fibras Nervosas , Retina , Glaucoma/diagnóstico , Tomografia de Coerência Óptica
13.
Invest Ophthalmol Vis Sci ; 65(4): 20, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38587439

RESUMO

Purpose: Axenfeld-Rieger syndrome (ARS) is characterized by ocular anomalies including posterior embryotoxon, iridocorneal adhesions, corectopia/iris hypoplasia, and developmental glaucoma. Although anterior segment defects and glaucoma contribute to decreased visual acuity, the role of potential posterior segment abnormalities has not been explored. We used high-resolution retinal imaging to test the hypothesis that individuals with ARS have posterior segment pathology. Methods: Three individuals with FOXC1-ARS and 10 with PITX2-ARS completed slit-lamp and fundus photography, optical coherence tomography (OCT), OCT angiography, and adaptive optics scanning light ophthalmoscopy (AOSLO). Quantitative metrics were compared to previously published values for individuals with normal vision. Results: All individuals demonstrated typical anterior segment phenotypes. Average ganglion cell and inner plexiform layer thickness was lower in PITX2-ARS, consistent with the glaucoma history in this group. A novel phenotype of foveal hypoplasia was noted in 40% of individuals with PITX2-ARS (but none with FOXC1-ARS). Moreover, the depth and volume of the foveal pit were significantly lower in PITX2-ARS compared to normal controls, even excluding individuals with foveal hypoplasia. Analysis of known foveal hypoplasia genes failed to identify an alternative explanation. Foveal cone density was decreased in one individual with foveal hypoplasia and normal in six without foveal hypoplasia. Two individuals (one from each group) demonstrated non-foveal retinal irregularities with regions of photoreceptor anomalies on OCT and AOSLO. Conclusions: These findings implicate PITX2 in the development of the posterior segment, particularly the fovea, in humans. The identified posterior segment phenotypes may contribute to visual acuity deficits in individuals with PITX2-ARS.


Assuntos
Segmento Anterior do Olho/anormalidades , Doenças da Córnea , Anormalidades do Olho , Oftalmopatias Hereditárias , Glaucoma , Humanos , Retina , Anormalidades do Olho/diagnóstico por imagem , Anormalidades do Olho/genética , Oftalmopatias Hereditárias/diagnóstico , Oftalmopatias Hereditárias/genética , Glaucoma/diagnóstico , Glaucoma/genética
14.
Transl Vis Sci Technol ; 13(4): 17, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591943

RESUMO

Purpose: To characterize the fundus tessellated density (FTD) in highly myopic glaucoma (HMG) and high myopia (HM) for discovering early signs and diagnostic markers. Methods: This retrospective cross-sectional study included hospital in-patients with HM (133 eyes) and HMG (73 eyes) with an axial length ≥26 mm at Zhongshan Ophthalmic Center. Using deep learning, FTD was quantified as the average exposed choroid area per unit area on fundus photographs in the global, macular, and disc regions. FTD-associated factors were assessed using partial correlation. Diagnostic efficacy was analyzed using the area under the curve (AUC). Results: HMG patients had lower global (0.20 ± 0.12 versus 0.36 ± 0.09) and macular FTD (0.25 ± 0.14 vs. 0.40 ± 0.09) but larger disc FTD (0.24 ± 0.11 vs. 0.19 ± 0.07) than HM patients in the tessellated fundus (all P < 0.001). In the macular region, nasal FTD was lowest in the HM (0.26 ± 0.13) but highest in the HMG (0.32 ± 0.13) compared with the superior, inferior, and temporal subregions (all P < 0.05). A fundus with a macular region nasal/temporal (NT) FTD ratio > 0.96 (AUC = 0.909) was 15.7 times more indicative of HMG than HM. A higher macular region NT ratio with a lower horizontal parapapillary atrophy/disc ratio indicated a higher possibility of HMG than HM (AUC = 0.932). Conclusions: FTD differs in degree and distribution between HMG and HM. A higher macular NT alone or with a lower horizontal parapapillary atrophy/disc ratio may help differentiate HMG. Translational Relevance: Deep learning-based FTD measurement could potentially assist glaucoma diagnosis in HM.


Assuntos
Aprendizado Profundo , Demência Frontotemporal , Glaucoma , Miopia , Humanos , Estudos Transversais , Estudos Retrospectivos , Glaucoma/complicações , Glaucoma/diagnóstico , Miopia/complicações , Miopia/diagnóstico , Atrofia , Corioide
15.
Transl Vis Sci Technol ; 13(4): 15, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38591945

RESUMO

Purpose: The purpose of this study was to estimate the distribution of the true rates of progression (RoP) of visual field (VF) loss. Methods: We analyzed the progression of mean deviation over time in series of ≥ 10 tests from 3352 eyes (one per patient) from 5 glaucoma clinics, using a novel Bayesian hierarchical Linear Mixed Model (LMM); this modeled the random-effect distribution of RoPs as the sum of 2 independent processes following, respectively, a negative exponential distribution (the "true" distribution of RoPs) and a Gaussian distribution (the "noise"), resulting in a skewed exGaussian distribution. The exGaussian-LMM was compared to a standard Gaussian-LMM using the Watanabe-Akaike Information Criterion (WAIC). The random-effect distributions were compared to the empirical cumulative distribution function (eCDF) of linear regression RoPs using a Kolmogorov-Smirnov test. Results: The WAIC indicated a better fit with the exGaussian-LMM (estimate [standard error]: 192174.4 [721.2]) than with the Gaussian-LMM (192595 [697.4], with a difference of 157.2 [22.6]). There was a significant difference between the eCDF and the Gaussian-LMM distribution (P < 0.0001), but not with the exGaussian-LMM distribution (P = 0.108). The estimated mean (95% credible intervals, CIs) "true" RoP (-0.377, 95% CI = -0.396 to -0.359 dB/year) was more negative than the observed mean RoP (-0.283, 95% CI = -0.299 to -0.268 dB/year), indicating a bias likely due to learning in standard LMMs. Conclusions: The distribution of "true" RoPs can be estimated with an exGaussian-LMM, improving model accuracy. Translational Relevance: We used these results to develop a fast and accurate analytical approximation for sample-size calculations in clinical trials using standard LMMs, which was integrated in a freely available web application.


Assuntos
Glaucoma , Campos Visuais , Humanos , Teorema de Bayes , Glaucoma/diagnóstico , Olho , Software
16.
Jpn J Ophthalmol ; 68(3): 183-191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598144

RESUMO

PURPOSE: To assess the impact of glaucoma on perceiving three-dimensional (3D) shapes based on monocular depth cues. STUDY DESIGN: Clinical observational study. METHODS: Twenty glaucoma patients, subjected to binocular visual-field sensitivity (binocular-VFS) tests using a Humphrey Visual Field Analyzer, and 20 age-matched healthy volunteers, underwent two tasks: identifying the nearest vertex of a 3D shape using monocular shading (3D-SfS), texture (3D-SfT), or motion (3D-SfM) cues, and distinguishing elementary one-dimensional (1D) features of these cues. The association of the visual-field index (VFI) of binocular-VFS with 3D shape perception in glaucoma patients was also examined. RESULTS: Glaucoma patients demonstrated reduced accuracy in distinguishing 1D luminance brightness and a larger "error-in-depth" between the perceived and actual depths for 3D-SfM and 3D-SfS compared to healthy volunteers. Six glaucoma patients with a 100% VFI for binocular-VFS exhibited a similar error-in-depth to the other fourteen glaucoma patients; they had a larger error-in-depth for 3D-SfM compared to healthy volunteers. No correlation between the error-in-depth values and the VFI values of binocular-VFS was observed. CONCLUSIONS: The 3D shape perception in glaucoma patients varies based on the depth cue's characteristics. Impaired 1D discrimination and larger thresholds for 3D-SfM in glaucoma patients with a 100% VFI for binocular-VFS indicate more pronounced perceptual deficits of lower-level elementary features for 3D-SfS and higher-level visual processing of 3D shapes for 3D-SfM. The effects of the location and degree of binocular visual-field defects on 3D shape perception remain to be elucidated. Our research provides insights into the 3D shape extraction mechanism in glaucoma.


Assuntos
Sinais (Psicologia) , Percepção de Profundidade , Glaucoma , Visão Binocular , Visão Monocular , Campos Visuais , Humanos , Masculino , Feminino , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Idoso , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Visão Monocular/fisiologia , Testes de Campo Visual , Pressão Intraocular/fisiologia , Percepção de Forma/fisiologia , Adulto
19.
Int Ophthalmol ; 44(1): 196, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662242

RESUMO

PURPOSE: Some patients refrained from seeking an ophthalmologist due to the anxiety and morbidity associated with the coronavirus disease (COVID-19) pandemic. We investigated progressive visual field defects in patients with glaucoma who refrained from ophthalmological examinations. METHODS: This was a retrospective study. We analyzed data from 886 patients with glaucoma who visited Inouye Eye Hospital in June 2022 and were followed-up prior to January 2020. We examined the number of times patients canceled visits between January 2020 and May 2022 due to coronavirus concerns. We assessed the mean deviation (MD) values of the Humphrey Visual Field Assessment (HFA) program 30-2 SITA Standard values after visit interruptions for worsening beyond the MD values predicted by the MD slope. Factors influencing this difference were analyzed using logistic regression analysis. RESULTS: The study included 374 men and 512 women. The mean age was 68.7 ± 12.0 years. Visit interruptions occurred in 146 patients (16.5%), with 95 (65.1%) rescheduling once, 27 (18.5%) twice, and 24 (16.4%) three or more times. Among 90 patients who underwent HFA regularly, 50 (55.6%) experienced worse-than-expected MD values and 12 (13.3%) deteriorated by 2 dB or more. Longer interruptions and high intraocular pressure before interruption worsened the MD values by 2 dB or more. CONCLUSION: Patients with glaucoma with visit interruptions due to the pandemic should be monitored for the progression of visual field impairment.


Assuntos
COVID-19 , Progressão da Doença , Glaucoma , SARS-CoV-2 , Campos Visuais , Humanos , COVID-19/epidemiologia , Masculino , Feminino , Estudos Retrospectivos , Idoso , Glaucoma/epidemiologia , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Pandemias , Testes de Campo Visual , Pressão Intraocular/fisiologia , Idoso de 80 Anos ou mais
20.
Transl Vis Sci Technol ; 13(4): 21, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38619925

RESUMO

Purpose: The purpose of this study was to explore risk factors for symptomatic presbyopia, defined as near add power ≥1.50 diopters, in patients with glaucoma. Methods: Treated glaucoma (n = 56), untreated glaucoma (n = 21), and control individuals (n = 376), aged 40 to 55 years at first visit, were enrolled in the study, and near add power, retinal thickness, and visual field were examined. The association between near add power and ocular parameters and the odds ratios (ORs) for symptomatic presbyopia were investigated. Survival analysis for symptomatic presbyopia was conducted. Results: Age, astigmatic power, mean deviation, and ganglion cell complex thickness were associated with near add power. The OR for symptomatic presbyopia was significant for age (OR = 1.51), astigmatism (OR = 1.01), mean deviation (OR = 0.72), ganglion cell complex thickness (OR = 0.98), treated and untreated glaucoma (OR = 2.09), and use of glaucoma eye drops (OR = 3.33). Survival analysis showed that the treated glaucoma group reached the near add power endpoint of ≥1.50 D (symptomatic presbyopia) significantly earlier than the other two groups, and there was no difference between the control and untreated glaucoma groups. Conclusions: Glaucoma patients treated with eye drops may start near correction earlier. Translational Relevance: Symptomatic presbyopia may develop earlier in patients with glaucoma, and our findings could further contribute to better management and understanding of presbyopia with glaucoma.


Assuntos
Glaucoma , Presbiopia , Humanos , Presbiopia/epidemiologia , Estudos Retrospectivos , Acuidade Visual , Estudos Transversais , Glaucoma/diagnóstico , Glaucoma/epidemiologia , Soluções Oftálmicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA