Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 151
Filtrar
1.
Crit Care Med ; 49(9): 1481-1492, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33870916

RESUMO

OBJECTIVES: To provide a comparative analysis of conventional heparin-versus bivalirudin-based systemic anticoagulation in adult and pediatric patients supported on extracorporeal membrane oxygenation. DESIGN: Retrospective chart review study of adult and pediatric patients receiving extracorporeal membrane oxygenation from January 1, 2014, to October 1, 2019. SETTING: A large, high-volume tertiary referral adult and pediatric extracorporeal membrane oxygenation center. PATIENTS: Four hundred twenty-four individuals requiring extracorporeal membrane oxygenation support and systemically anticoagulated with either unfractionated heparin (223 adult and 65 pediatric patients) or bivalirudin (110 adult and 24 pediatric patients) were included. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Digital data abstraction was used to retrospectively collect patient details. The majority of both groups were cannulated centrally (67%), and the extracorporeal membrane oxygenation type was predominantly venoarterial (84%). The adult bivalirudin group had a greater occurrence of heparin-induced thrombocytopenia (12% vs 1%; p < 0.01) and was more likely to require postcardiotomy extracorporeal membrane oxygenation (36% vs 55%; p < 0.01). There were no statistical differences between the groups in regards to age, sex, and extracorporeal membrane oxygenation initiation location. The main finding was a reduced mortality in the adult bivalirudin group (odds ratio, 0.39; p < 0.01), whereas no difference was noted in the pediatric group. A significant reduction in the composite transfusion requirement in the first 24 hours was noted in the pediatric bivaluridin group with an odds ratio of 0.28 (p = 0.02). Groups did not differ in regard to laboratories per day, anticoagulant dose adjustments, or ischemic complications. CONCLUSIONS: When compared with heparin-based systemic anticoagulation, bivalirudin demonstrated feasibility and safety as established by the absence of increases in identifiable adverse outcomes while manifesting substantial improvements in hospital mortality in adult patients. Further studies are necessary to corroborate these findings and further elucidate the role of bivalirudin during extracorporeal membrane oxygenation support.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Heparina/normas , Hirudinas/normas , Fragmentos de Peptídeos/normas , Adolescente , Adulto , Anticoagulantes/normas , Anticoagulantes/uso terapêutico , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Fragmentos de Peptídeos/uso terapêutico , Proteínas Recombinantes/normas , Proteínas Recombinantes/uso terapêutico , Estudos Retrospectivos
2.
Crit Care ; 25(1): 160, 2021 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-33910609

RESUMO

BACKGROUND: During venovenous extracorporeal membrane oxygenation (vvECMO), direct thrombin inhibitors are considered by some potentially advantageous over unfractionated heparin (UFH). We tested the hypothesis that Argatroban is non-inferior to UFH regarding thrombosis and bleeding during vvECMO. METHODS: We conducted a propensity-score matched observational non-inferiority study of consecutive patients without heparin-induced-thrombocytopenia (HIT) on vvECMO, treated between January 2006 and March 2019 in the medical intensive care unit at the University Hospital Regensburg. Anticoagulation was realized with UFH until August 2017 and with Argatroban from September 2017 onwards. Target activated partial thromboplastin time was 50 ± 5seconds in both groups. Primary composite endpoint was major thrombosis and/or major bleeding. Major bleeding was defined as a drop in hemoglobin of ≥ 2 g/dl/day or in transfusion of ≥ 2 packed red cells/24 h, or retroperitoneal, cerebral, or pulmonary bleeding. Major thrombosis was defined as obstruction of > 50% of the vessel lumen diameter by means of duplex sonography. We also assessed technical complications such as oxygenator defects or pump head thrombosis, the time-course of platelets, and the cost of anticoagulation (including HIT-testing). RESULTS: Out of 465 patients receiving UFH, 78 were matched to 39 patients receiving Argatroban. The primary endpoint occurred in 79% of patients in the Argatroban group and in 83% in the UFH group (non-inferiority for Argatroban, p = 0.026). The occurrence of technical complications was equally distributed (Argatroban 49% vs. UFH 42%, p = 0.511). The number of platelets was similar in both groups before ECMO therapy but lower in the UFH group after end of ECMO support (median [IQR]: 141 [104;198]/nl vs. 107 [54;171]/nl, p = 0.010). Anticoagulation costs per day of ECMO were higher in the Argatroban group (€26 [13.8;53.0] vs. €0.9 [0.5;1.5], p < 0.001) but not after accounting for blood products and HIT-testing (€63 [42;171) vs. €40 [17;158], p = 0.074). CONCLUSION: In patients without HIT on vvECMO, Argatroban was non-inferior to UFH regarding bleeding and thrombosis. The occurrence of technical complications was similarly distributed. Argatroban may have less impact on platelet decrease during ECMO, but this finding needs further evaluation. Direct drug costs were higher for Argatroban but comparable to UFH after accounting for HIT-testing and transfusions.


Assuntos
Arginina/análogos & derivados , Oxigenação por Membrana Extracorpórea/métodos , Heparina/normas , Ácidos Pipecólicos/normas , Sulfonamidas/normas , Trombocitopenia/prevenção & controle , Adulto , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Antitrombinas/efeitos adversos , Antitrombinas/normas , Arginina/efeitos adversos , Arginina/normas , Estudos de Equivalência como Asunto , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Alemanha , Heparina/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Ácidos Pipecólicos/efeitos adversos , Pontuação de Propensão , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Sulfonamidas/efeitos adversos
3.
Medicina (Kaunas) ; 55(10)2019 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-31557911

RESUMO

Heparin is a vital pharmaceutical anticoagulant drug and remains one of the few naturally sourced pharmaceutical agents used clinically. Heparin possesses a structural order with up to four levels of complexity. These levels are subject to change based on the animal or even tissue sources that they are extracted from, while higher levels are believed to be entirely dynamic and a product of their surrounding environments, including bound proteins and associated cations. In 2008, heparin sources were subject to a major contamination with a deadly compound-an over-sulphated chondroitin sulphate polysaccharide-that resulted in excess of 100 deaths within North America alone. In consideration of this, an arsenal of methods to screen for heparin contamination have been applied, based primarily on the detection of over-sulphated chondroitin sulphate. The targeted nature of these screening methods, for this specific contaminant, may leave contamination by other entities poorly protected against, but novel approaches, including library-based chemometric analysis in concert with a variety of spectroscopic methods, could be of great importance in combating future, potential threats.


Assuntos
Sulfatos de Condroitina/análise , Heparina/química , Heparina/normas , Preparações Farmacêuticas/química , Preparações Farmacêuticas/normas , Controle de Qualidade , Animais , Sulfatos de Condroitina/isolamento & purificação , Cromatografia Líquida de Alta Pressão , Contaminação de Medicamentos , Humanos , Espectroscopia de Ressonância Magnética , Análise de Componente Principal
4.
Anesth Analg ; 126(2): 413-424, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29346209

RESUMO

Despite more than a half century of "safe" cardiopulmonary bypass (CPB), the evidence base surrounding the conduct of anticoagulation therapy for CPB has not been organized into a succinct guideline. For this and other reasons, there is enormous practice variability relating to the use and dosing of heparin, monitoring heparin anticoagulation, reversal of anticoagulation, and the use of alternative anticoagulants. To address this and other gaps, The Society of Thoracic Surgeons, the Society of Cardiovascular Anesthesiologists, and the American Society of Extracorporeal Technology developed an Evidence Based Workgroup. This was a group of interdisciplinary professionals gathered to summarize the evidence and create practice recommendations for various aspects of CPB. To date, anticoagulation practices in CPB have not been standardized in accordance with the evidence base. This clinical practice guideline was written with the intent to fill the evidence gap and to establish best practices in anticoagulation therapy for CPB using the available evidence. To identify relevant evidence, a systematic review was outlined and literature searches were conducted in PubMed using standardized medical subject heading (MeSH) terms from the National Library of Medicine list of search terms. Search dates were inclusive of January 2000 to December 2015. The search yielded 833 abstracts, which were reviewed by two independent reviewers. Once accepted into the full manuscript review stage, two members of the writing group evaluated each of 286 full papers for inclusion eligibility into the guideline document. Ninety-six manuscripts were included in the final review. In addition, 17 manuscripts published before 2000 were included to provide method, context, or additional supporting evidence for the recommendations as these papers were considered sentinel publications. Members of the writing group wrote and developed recommendations based on review of the articles obtained and achieved more than two thirds agreement on each recommendation. The quality of information for a given recommendation allowed assessment of the level of evidence as recommended by the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Recommendations were written in the three following areas: (1) heparin dosing and monitoring for initiation and maintenance of CPB; (2) heparin contraindications and heparin alternatives; and (3) reversal of anticoagulation during cardiac operations. It is hoped that this guideline will serve as a resource and will stimulate investigators to conduct more research and to expand on the evidence base on the topic of anticoagulation therapy for CPB.


Assuntos
Anestesiologistas/normas , Anticoagulantes/normas , Procedimentos Cirúrgicos Cardíacos/normas , Circulação Extracorpórea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Anticoagulantes/administração & dosagem , Procedimentos Cirúrgicos Cardíacos/métodos , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/normas , Circulação Extracorpórea/métodos , Heparina/administração & dosagem , Heparina/normas , Humanos , Procedimentos Cirúrgicos Torácicos/métodos , Procedimentos Cirúrgicos Torácicos/normas
5.
J Pharm Biomed Anal ; 149: 128-132, 2018 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-29112901

RESUMO

Apart from the characterization of impurities, the full characterization of heparin and low molecular weight heparin (LMWH) also requires the determination of average molecular weight, which is closely related to the pharmaceutical properties of anticoagulant drugs. To determine average molecular weight of these animal-derived polymer products, partial least squares regression (PLS) was utilized for modelling of diffused-ordered spectroscopy NMR data (DOSY) of a representative set of heparin (n=32) and LMWH (n=30) samples. The same sets of samples were measured by gel permeation chromatography (GPC) to obtain reference data. The application of PLS to the data led to calibration models with root mean square error of prediction of 498Da and 179Da for heparin and LMWH, respectively. The average coefficients of variation (CVs) did not exceed 2.1% excluding sample preparation (by successive measuring one solution, n=5) and 2.5% including sample preparation (by preparing and analyzing separate samples, n=5). An advantage of the method is that the sample after standard 1D NMR characterization can be used for the molecular weight determination without further manipulation. The accuracy of multivariate models is better than the previous results for other matrices employing internal standards. Therefore, DOSY experiment is recommended to be employed for the calculation of molecular weight of heparin products as a complementary measurement to standard 1D NMR quality control. The method can be easily transferred to other matrices as well.


Assuntos
Anticoagulantes/química , Biopolímeros/química , Espectroscopia de Ressonância Magnética/métodos , Modelos Químicos , Controle de Qualidade , Animais , Anticoagulantes/análise , Anticoagulantes/normas , Calibragem , Bovinos , Química Farmacêutica/instrumentação , Química Farmacêutica/métodos , Difusão , Guias como Assunto , Heparina/análise , Heparina/química , Heparina/normas , Heparina de Baixo Peso Molecular/análise , Heparina de Baixo Peso Molecular/química , Heparina de Baixo Peso Molecular/normas , Análise dos Mínimos Quadrados , Espectroscopia de Ressonância Magnética/instrumentação , Peso Molecular , Padrões de Referência , Ovinos , Suínos , Tecnologia Farmacêutica/instrumentação , Tecnologia Farmacêutica/métodos , Tecnologia Farmacêutica/normas
6.
Molecules ; 22(7)2017 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-28698456

RESUMO

Because of the complexity and global nature of the heparin supply chain, the control of heparin quality during manufacturing steps is essential to ensure the safety of the final active pharmaceutical ingredient (API). For this reason, there is a need to develop consistent analytical methods able to assess the quality of heparin early in production (i.e., as the crude heparin before it is purified to API under cGMP conditions). Although a number of analytical techniques have been applied to characterize heparin APIs, few of them have been applied for crude heparin structure and composition analyses. Here, to address this issue, NMR spectroscopy and chemometrics were applied to characterize 88 crude heparin samples. The samples were also analyzed by strong anion exchange HPLC (SAX-HPLC) as an orthogonal check of the purity levels of the crudes analyzed by NMR. The HPLC data showed that the chemometric analysis of the NMR data differentiated the samples based on their purity. These orthogonal approaches differentiated samples according their glycosaminoglycan (GAG) composition and their mono and disaccharide composition and structure for each GAG family (e.g., heparin/heparan, dermatan sulfate, and chondroitin sulfate A). Moreover, quantitative HSQC and multivariate analysis (PCA) were used to distinguish between crude heparin of different animal and tissue sources.


Assuntos
Dermatan Sulfato/química , Glicosaminoglicanos/química , Heparina/química , Animais , Cromatografia Líquida de Alta Pressão , Dermatan Sulfato/isolamento & purificação , Contaminação de Medicamentos , Glicosaminoglicanos/isolamento & purificação , Heparina/isolamento & purificação , Heparina/normas , Humanos , Espectroscopia de Ressonância Magnética , Controle de Qualidade
7.
Nat Biotechnol ; 34(6): 625-30, 2016 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-27281424

RESUMO

The contamination of the widely used lifesaving anticoagulant drug heparin in 2007 has drawn renewed attention to the challenges that are associated with the characterization, quality control and standardization of complex biological medicines from natural sources. Heparin is a linear, highly sulfated polysaccharide consisting of alternating glucosamine and uronic acid monosaccharide residues. Heparin has been used successfully as an injectable antithrombotic medicine since the 1930s, and its isolation from animal sources (primarily porcine intestine) as well as its manufacturing processes have not changed substantially since its introduction. The 2007 heparin contamination crisis resulted in several deaths in the United States and hundreds of adverse reactions worldwide, revealing the vulnerability of a complex global supply chain to sophisticated adulteration. This Perspective discusses how the US Food and Drug Administration (FDA), the United States Pharmacopeial Convention (USP) and international stakeholders collaborated to redefine quality expectations for heparin, thus making an important natural product better controlled and less susceptible to economically motivated adulteration.


Assuntos
Contaminação de Medicamentos/legislação & jurisprudência , Contaminação de Medicamentos/prevenção & controle , Saúde Global/legislação & jurisprudência , Heparina/normas , Farmacopeias como Assunto/normas , Vigilância de Produtos Comercializados/normas , Saúde Global/normas , Regulamentação Governamental , Legislação de Medicamentos , Guias de Prática Clínica como Assunto , Estados Unidos , United States Food and Drug Administration/legislação & jurisprudência
8.
Clin Appl Thromb Hemost ; 22(6): 520-7, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27084870

RESUMO

Heparin is a widely used clinical anticoagulant. It is also a linear glycosaminoglycan with an average mass between 10 and 20 kDa and is primarily made up of trisulfated disaccharides comprised of 1,4-linked iduronic acid and glucosamine residues containing some glucuronic acid residues. Heparin is biosynthesized in the Golgi of mast cells commonly found in the liver, intestines, and lungs. Pharmaceutical heparin currently used in the United States is primarily extracted from porcine intestines. Other sources of heparin including bovine intestine and bovine lung are being examined as potential substitutes for porcine intestinal heparin. These additional sources are intended to serve to diversify the heparin supply, making this lifesaving drug more secure. The current study examines bovine heparins prepared from both intestines and lung and compares these to porcine intestinal heparin. The structural properties of these heparins are examined using nuclear magnetic resonance, gel permeation chromatography, and disaccharide analysis of heparinase-catalyzed depolymerized heparin. The in vitro functional activities of these heparins have also been determined. The goal of this study is to establish the structural and functional similarities and potential differences between bovine and porcine heparins. Porcine and bovine heparins have structural and compositional similarities and differences.


Assuntos
Heparina/análise , Animais , Anticoagulantes , Testes de Coagulação Sanguínea , Bovinos , Heparina/química , Heparina/normas , Intestinos/química , Pulmão/química , Estrutura Molecular , Peso Molecular , Suínos
9.
Clin Appl Thromb Hemost ; 22(5): 423-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26842561

RESUMO

The introduction of oral direct anti-Xa anticoagulants apixaban and rivaroxaban has significantly impacted the treatment and prevention of thromboembolic disease. Clinical scenarios exist in which a quantitative assessment for degree of anticoagulation due to these agents would aid management. The purpose of this work was to evaluate the chromogenic antifactor Xa assay calibrated with heparin standards at our institution for assessment of intensity of anticoagulation with rivaroxaban or apixaban in addition to its current use for unfractionated heparin or low-molecular-weight heparin. We also aimed to propose expected steady state peak and trough antifactor Xa activities for these agents based upon dosing regimens approved for nonvalvular atrial fibrillation. Antifactor Xa activity correlated very strongly with apixaban and rivaroxaban concentration in both spiked samples and treated patient plasma samples (r (2) = .99, P < .001). This correlation was observed over a broad range (20-500 ng/mL) of drug concentrations, as sample dilution with pooled normal plasma significantly extended the range of quantitative assessment. Based on drug concentrations previously published in pharmacokinetic studies, the expected steady state peak and trough antifactor Xa activity ranges for apixaban are 1.80 to 2.20 IU/mL and 0.70 to 1.10 IU/mL, respectively. For rivaroxaban, these ranges are 3.80 to 6.20 IU/mL and 0.60 to 1.00 IU/mL, respectively. In conclusion, our findings demonstrate that heparin-calibrated antifactor Xa activity correlates strongly with apixaban and rivaroxaban concentration. The dilution of samples allowed for this correlation to be extended over the majority of on-therapy drug concentrations.


Assuntos
Testes de Coagulação Sanguínea/métodos , Inibidores do Fator Xa/farmacologia , Tromboembolia/tratamento farmacológico , Anticoagulantes/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Testes de Coagulação Sanguínea/normas , Calibragem , Relação Dose-Resposta a Droga , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/uso terapêutico , Heparina/normas , Humanos , Pirazóis/farmacologia , Piridonas/farmacologia , Rivaroxabana/farmacologia
10.
J Pharm Biomed Anal ; 115: 543-51, 2015 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-26319747

RESUMO

(1)H NMR spectroscopy was used to distinguish pure porcine heparin and porcine heparin blended with bovine species and to quantify the degree of such adulteration. For multivariate modelling several statistical methods such as partial least squares regression (PLS), ridge regression (RR), stepwise regression with variable selection (SR), stepwise principal component regression (SPCR) were utilized for modeling NMR data of in-house prepared blends (n=80). The models were exhaustively validated using independent test and prediction sets. PLS and RR showed the best performance for estimating heparin falsification regarding its animal origin with the limit of detection (LOD) and root mean square error of validation (RMSEV) below 2% w/w and 1% w/w, respectively. Reproducibility expressed in coefficients of variation was estimated to be below 10% starting from approximately 5% w/w of bovine adulteration. Acceptable calibration model was obtained by SPCR, by its application range was limited, whereas SR is least recommended for heparin matrix. The developed method was found to be applicable also to heparinoid matrix (not purified heparin). In this case root mean square of prediction (RMSEP) and LOD were approximately 7% w/w and 8% w/w, respectively. The simple and cheap NMR method is recommended for screening of heparin animal origin in parallel with official NMR test of heparin authenticity and purity.


Assuntos
Contaminação de Medicamentos , Heparina/análise , Espectroscopia de Prótons por Ressonância Magnética , Animais , Calibragem , Bovinos , Heparina/normas , Análise dos Mínimos Quadrados , Análise Multivariada , Análise de Componente Principal , Espectroscopia de Prótons por Ressonância Magnética/normas , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Especificidade da Espécie , Suínos
11.
Bull Exp Biol Med ; 158(4): 450-2, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25708323

RESUMO

We compared anti-IIa activity of a heparin analogue and a reference product was carried out to confirm their biosimilarity. The experiment was based on the method of estimation of anti-IIa activity of a commercial sodium heparin preparation according to United States Pharmacopoeia. High similarity of the two medicinal heparin preparations by this parameter is shown. The method is recommended for the use in comparability studies.


Assuntos
Medicamentos Biossimilares/farmacologia , Sulfatos de Condroitina/efeitos adversos , Hipersensibilidade a Drogas/metabolismo , Heparina/análise , Heparina/farmacologia , Protrombina/antagonistas & inibidores , Análise de Variância , Animais , Bovinos , Sulfatos de Condroitina/química , Heparina/normas , Análise de Regressão , Federação Russa , Especificidade da Espécie , Suínos
12.
J Cardiothorac Vasc Anesth ; 28(5): 1227-32, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281041

RESUMO

OBJECTIVE: UFH (unfractionated heparin) and protamine are integral to cardiac surgery, and inappropriate dosing can predispose to coagulopathy and hemorrhage. The FDA (Food and Drug Administration) recently has instituted changes to UFH formulation and it is not known if this has influenced its susceptibility to neutralization by protamine. Hence, the authors sought to compare 2 commercial preparations of UFH (old and new) with regard to their neutralization by protamine in patients undergoing cardiopulmonary bypass (CPB). DESIGN: Prospective, observational, cohort study. SETTING: Tertiary care university hospital and associated research laboratory PARTICIPANTS: Twenty adult patients undergoing elective cardiac surgery with CPB. INTERVENTIONS: Blood samples were drawn preinduction, prior to, and 5 and 30 minutes following protamine, and 0 and 2 hours after ICU admission. Protamine titration assays were conducted in vitro on samples drawn prior to and following protamine administration. Anti-IIa and anti-Xa activity were assayed in all samples. RESULTS: Anti-IIa and anti-Xa activity were detected ubiquitously at all time points following CPB, and there were no differences in susceptibility to protamine neutralization between the 2 groups. In vitro protamine titration studies revealed that anti-IIa was more resistant to protamine neutralization compared to anti-Xa activity. CONCLUSIONS: The 'old' and 'new' formulations of UFH evaluated in this study were similar in their susceptibility to protamine neutralization. Circulating UFH is detected as early as 5 minutes after protamine administration and anti-IIa is more resistant to protamine neutralization as compared to anti-Xa activity. Further studies are required to quantify the precise dose of protamine following CPB.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Heparina/normas , Heparina/uso terapêutico , Protaminas/normas , Protaminas/uso terapêutico , Idoso , Animais , Procedimentos Cirúrgicos Cardíacos/tendências , Química Farmacêutica , Estudos de Coortes , Feminino , Heparina/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Protaminas/sangue , Padrões de Referência , Suínos
13.
Pharmeur Bio Sci Notes ; 2014: 103-17, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25655247

RESUMO

Following the heparin adulteration crisis, the European Pharmacopoeia (Ph. Eur.) Group of Experts on Biologicals (Group 6) considered a revision of the general chapter 2.7.5. Assay of heparin with regard to the assay of the anticoagulant activity of heparin in order to replace the clotting method with more specific chromogenic methods for anti-IIa and anti-Xa activities. An international collaborative study was carried out in 3 phases under the aegis of the Biological Standardisation Programme (BSP) of the Council of Europe and the European Commission in order to recalibrate Heparin sodium Biological Reference Preparation (BRP) batch 3 for these new assays. Phase 1 confirmed the feasibility of the project, but also indicated that the composition of the buffers affects the assay results, thereby highlighting the importance of using common assay procedures. Phase 2 consisted of a collaborative study involving 15 laboratories to calibrate the anti-IIa and anti-Xa activities of Heparin sodium BRP batch 3. The collaborative study confirmed that Heparin sodium BRP batch 3 is suitable for use as a reference preparation in the proposed chromogenic assays for unfractionated heparin. It also showed that the currently defined acceptance limits (90 % to 111 %) can be maintained in the revised Ph. Eur. texts. Phase 3 of the study collected data on the impact of the new unitage on the release of products marketed in Europe. The data from 5 manufacturers, who each reported results from both the clotting and chromogenic assays for a total of 23 batches, indicated that the replacement of the pharmacopoeial method is unlikely to cause batch release issues. Based on the results of this study, the Ph. Eur. Commission assigned Heparin sodium BRP batch 3 with a potency of 1000 IU/vial for both anti-IIa and anti-Xa activities in the chromogenic assays.


Assuntos
Heparina/normas , Calibragem , Comportamento Cooperativo , Europa (Continente) , Heparina/análise , Humanos , Padrões de Referência
14.
J Extra Corpor Technol ; 45(2): 112-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23930380

RESUMO

In October 2009, the U.S. Pharmacopoeia (USP) changed the monograph for heparin to bring USP units in line with international units for heparin. The result was a 10% decrease in potency as measured by in vitro laboratory tests. This decrease led to questions regarding dosing guidelines. There existed a need for an in vivo study to determine the practical changes that may need to be implemented in regard to heparin administration for cardiopulmonary bypass in the clinical setting. A retrospective study was conducted to determine the heparin dose administered and the corresponding effect on patients undergoing coronary artery bypass grafting surgery using cardiopulmonary bypass. The study compared the heparin dose requirements and activated clotting time (ACT) results using the heparin before and after the USP changes. An analysis of the data was performed to determine the increased heparin dose required to achieve the same effect as before the USP change. This new heparin dosing protocol was instituted at Concord Hospital, Concord, NH. A prospective study was then preformed to verify the effects of the dosing change. In the new heparin group, the postheparin ACT fell by 9.1% (p = .028) and the patients achieving an ACT > 479 seconds fell by 12.8% as compared with the old heparin group. After adjustment of the loading dose calculation for heparin, the prospective study demonstrated the postheparin ACT (p = .684) and the percentage of patients achieving an ACT > 479 seconds (p = 1.000) to be similar to the values obtained before the USP change. An increase of the loading dose of approximately 12% is needed to achieve the patient effects seen before the UPS change.


Assuntos
Ponte Cardiopulmonar/estatística & dados numéricos , Ponte Cardiopulmonar/normas , Heparina/sangue , Heparina/normas , Sistema Internacional de Unidades , Tempo de Coagulação do Sangue Total/estatística & dados numéricos , Tempo de Coagulação do Sangue Total/normas , Anticoagulantes/sangue , Anticoagulantes/normas , Humanos , Padrões de Referência , Estados Unidos
15.
Electrophoresis ; 33(11): 1531-7, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22736353

RESUMO

The adulteration of raw heparin with oversulfated chondroitin sulfate (OSCS) in 2007-2008 produced a global crisis resulting in extensive revisions to the pharmacopeia monographs and prompting the FDA to recommend the development of additional methods for the analysis of heparin purity. As a consequence, a wide variety of innovative analytical approaches have been developed for the quality assurance and purity of unfractionated and low-molecular-weight heparins. This review discusses recent developments in electrophoresis techniques available for the sensitive separation, detection, and partial structural characterization of heparin contaminants. In particular, this review summarizes recent publications on heparin quality and related impurity analysis using electrophoretic separations such as capillary electrophoresis (CE) of intact polysaccharides and hexosamines derived from their acidic hydrolysis, and polyacrylamide gel electrophoresis (PAGE) for the separation of heparin samples without and in the presence of its relatively specific depolymerization process with nitrous acid treatment.


Assuntos
Sulfatos de Condroitina/análise , Eletroforese/métodos , Heparina/análise , Heparina/normas , Sulfatos de Condroitina/química , Contaminação de Medicamentos , Heparina/química
16.
Anal Bioanal Chem ; 404(1): 43-50, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22648164

RESUMO

Heparin is a widely used intravenous anticoagulant comprising of a very complex mixture of glycosaminoglycan chains, mainly derived from porcine intestinal mucosa. The species of origin and the absence of contaminants from other species are important determinants of the different physicochemical characteristics of heparin. They also determine the potential for introducing infectious and adventitious agents into heparin batches destined for medicinal use. We perform routine quantitative polymerase chain reaction (Q-PCR) release tests to confirm the quality of all crude heparin batches, including those used for the manufacture of enoxaparin sodium. Here we further demonstrate that the assessment of the DNA content in crude heparin is a good surrogate marker of contamination at the mucosa level. After spiking porcine mucosa with ovine mucosa and processing this material to form crude heparin, we were able to observe similar ratios of species-specific DNA in both the starting and end products. Experiments performed with 3,000 and 1,500 ppm contamination found these concentrations to be well above the detection limit for our assay of heparin batches. Additionally this Q-PCR method can be used to detect contamination in mucosa, thus providing a tool capable of monitoring for contaminants throughout the crude heparin manufacturing process. Q-PCR analysis of industrial crude heparin samples has confirmed over time the value of this method to assess the pure porcine origin of heparin.


Assuntos
DNA/genética , Contaminação de Medicamentos/prevenção & controle , Heparina/química , Reação em Cadeia da Polimerase/métodos , Ovinos/genética , Suínos/genética , Animais , Biomarcadores/análise , Heparina/normas , Limite de Detecção , Controle de Qualidade , Especificidade da Espécie
17.
Handb Exp Pharmacol ; (207): 3-22, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22566218

RESUMO

The history of heparin is described from its initial discovery in 1916 to recent developments in knowledge of its mechanism of action and clinical use. Commercial production started soon after its discovery, in the 1920s, and improved purification methods led to animal studies and the first clinical trials in the 1930s. Research into heparin's chemical structure proved difficult, with uncertainty about the uronic acid moiety and the N-acetyl content, but the structure of the basic disaccharide unit was established by the 1960s, though knowledge of the heterogeneity and fine structure of heparin chains continued to accumulate over the next 20 years. In 1976, it was found that only one third of heparin chains bound with high affinity to antithrombin, and subsequent studies identified a unique pentasaccharide sequence, which was essential for antithrombin binding and anticoagulant activity - this pentasaccharide was synthesised in 1983. Clinical usage of heparin continued to increase and two major developments were the use of low- dose heparin for prevention of deep vein thrombosis and pulmonary embolism, and the development of low-molecular-weight heparin as a separate drug.


Assuntos
Heparina/história , Heparina/química , Heparina/farmacologia , Heparina/normas , História do Século XX , História do Século XXI
18.
Pediatr Nephrol ; 27(10): 1869-79, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22374405

RESUMO

Despite advances in biomaterials and dialyzer design, thrombin generation occurs in the dialysis circuit because of platelet and leukocyte activation. As such, anticoagulation is required by the majority of children for successful dialysis to prevent clotting in the venous air detector and the capillary dialyzer, particularly for small children with slower blood flow rates. For many years unfractionated heparin has been the standard anticoagulant of choice, but is now being challenged by low-molecular-weight heparins (LMWHs) because they are simple to administer and reliable, particularly as the cost differential has been eroded. Alternative, nonheparin anticoagulants are more frequently available, but are often restricted to special circumstances: patients at high risk of hemorrhage; heparin allergy; or heparin-induced thrombocytopenia. These nonheparin alternatives are significantly more expensive than heparins, and may add a degree of complexity, such as citrate, which is a regional anticoagulant, although citrate-containing dialysate may permit short anticoagulant-free dialysis sessions. Systemic anticoagulants required for immune-mediated, heparin-induced thrombocytopenia are expensive and either have short half-lives, and therefore require continuous infusions, or prolonged half-lives, which, although allowing simple bolus administration, increases the risk of drug accumulation, over-dosage and hemorrhage.


Assuntos
Anticoagulantes/uso terapêutico , Coagulação Sanguínea/efeitos dos fármacos , Heparina/uso terapêutico , Diálise Renal , Fatores Etários , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Anticoagulantes/farmacocinética , Anticoagulantes/normas , Criança , Pré-Escolar , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Hemorragia/induzido quimicamente , Heparina/administração & dosagem , Heparina/efeitos adversos , Heparina/farmacocinética , Heparina/normas , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Lactente , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Diálise Renal/efeitos adversos , Diálise Renal/instrumentação , Diálise Renal/normas , Medição de Risco , Fatores de Risco , Resultado do Tratamento
19.
Jt Comm J Qual Patient Saf ; 37(3): 99-109, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21500752

RESUMO

BACKGROUND: Lean principles have been used at Denver Health Medical Center since 2005 to streamline nonclinical processes. Despite allocation of significant resources, particularly the expense of low molecular weight heparin (LMWH), to prophylaxis of venous thromboembolism (VTE), the incidence of postoperative VTE was significantly worse than national benchmarks. VTE risk factors were not consistently assessed, and the prescribing of prophylaxis varied widely. Lean was employed to standardize and implement risk assessment and evidence-based VTE prophylaxis for the institution. METHODS: In a rapid improvement event, a multidisciplinary group formulated an evidence-based risk assessment tool and clinical practice guideline for VTE prophylaxis, with plans for hospitalwide implementation and monitoring. RESULTS: The effects were immediate and improved steadily with feedback to clinicians. Within six months, compliance with the standard approached 100%. One year after implementation, the use of LMWH decreased more than 60% below baseline, and the use of sequential compression devices decreased by nearly 30%. With increased use of unfractionated heparin, the cost savings on VTE prophylaxis exceeded $15,000 per month, for a total of $425,000 since implementation. Moreover, the incidence of VTE decreased markedly during the same period. By reducing VTE rates, a total cost savings of $6.2 million was estimated for the past 28 months. CONCLUSIONS: Applying Lean to the clinical management of VTE prophylaxis improved compliance with standards and saved the hospital a significant amount of money. This was achieved without compromising clinical outcomes. This experience could be replicated at other institutions.


Assuntos
Anticoagulantes/uso terapêutico , Heparina/uso terapêutico , Tromboembolia Venosa/prevenção & controle , Anticoagulantes/economia , Anticoagulantes/normas , Centers for Medicare and Medicaid Services, U.S./economia , Centers for Medicare and Medicaid Services, U.S./normas , Colorado , Análise Custo-Benefício , Heparina/economia , Heparina/normas , Humanos , Dispositivos de Compressão Pneumática Intermitente , Estudos de Casos Organizacionais , Inovação Organizacional , Avaliação de Processos e Resultados em Cuidados de Saúde , Recursos Humanos em Hospital/educação , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/prevenção & controle , Guias de Prática Clínica como Assunto , Melhoria de Qualidade/economia , Melhoria de Qualidade/normas , Reembolso de Incentivo/normas , Medição de Risco/economia , Medição de Risco/métodos , Medição de Risco/normas , Desenvolvimento de Pessoal/métodos , Estados Unidos , Tromboembolia Venosa/economia , Tromboembolia Venosa/etiologia
20.
PLoS One ; 6(1): e15970, 2011 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-21267460

RESUMO

The year 2007 was marked by widespread adverse clinical responses to heparin use, leading to a global recall of potentially affected heparin batches in 2008. Several analytical methods have since been developed to detect impurities in heparin preparations; however, many are costly and dependent on instrumentation with only limited accessibility. A method based on a simple UV-scanning assay, combined with principal component analysis (PCA), was developed to detect impurities, such as glycosaminoglycans, other complex polysaccharides and aromatic compounds, in heparin preparations. Results were confirmed by NMR spectroscopy. This approach provides an additional, sensitive tool to determine heparin purity and safety, even when NMR spectroscopy failed, requiring only standard laboratory equipment and computing facilities.


Assuntos
Heparina/normas , Espectroscopia de Ressonância Magnética , Análise de Componente Principal , Espectrofotometria Ultravioleta , Contaminação de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Espectroscopia de Ressonância Magnética/métodos , Métodos , Padrões de Referência , Espectrofotometria Ultravioleta/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA