Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Sci Rep ; 12(1): 2121, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35136119

RESUMO

The aim of the study was to evaluate the role of pseudocontinuous arterial spin labeling perfusion (pCASL-perfusion) in preoperative assessment of cerebral glioma grades. The study group consisted of 253 patients, aged 7-78 years with supratentorial gliomas (65 low-grade gliomas (LGG), 188 high-grade gliomas (HGG)). We used 3D pCASL-perfusion for each patient in order to calculate the tumor blood flow (TBF). We obtained maximal tumor blood flow (maxTBF) in small regions of interest (30 ± 10 mm2) and then normalized absolute maximum tumor blood flow (nTBF) to that of the contralateral normal-appearing white matter of the centrum semiovale. MaxTBF and nTBF values significantly differed between HGG and LGG groups (p < 0.001), as well as between patient groups separated by the grades (grade II vs. grade III) (p < 0.001). Moreover, we performed ROC-analysis which demonstrated high sensitivity and specificity in differentiating between HGG and LGG. We found significant differences for maxTBF and nTBF between grade III and IV gliomas, however, ROC-analysis showed low sensitivity and specificity. We did not observe a significant difference in TBF for astrocytomas and oligodendrogliomas. Our study demonstrates that 3D pCASL-perfusion as an effective diagnostic tool for preoperative differentiation of glioma grades.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Glioma/diagnóstico por imagem , Angiografia por Ressonância Magnética/estatística & dados numéricos , Imagem de Perfusão/estatística & dados numéricos , Adolescente , Adulto , Idoso , Neoplasias Encefálicas/irrigação sanguínea , Criança , Feminino , Glioma/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estudos Retrospectivos , Adulto Jovem
2.
Burns ; 47(1): 157-170, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33277087

RESUMO

BACKGROUND: Determination of the depth of burn wounds is still a challenge in clinical practise and fundamental for an optimal treatment. Hyperspectral imaging (HSI) has a high potential to be established as a new contact-free measuring method in medicine. From hyperspectral spectra 3D-perfusion parameters can be estimated and the microcirculatory of burn wounds over the first 72h after thermal injury can be objectively described. METHODS: We used a hyperspectral imaging camera and extended data processing methods to calculate 3D-perfusion parameters of burn wounds from adult patients. The data processing results in the estimation of perfusion parameters like volume fraction and oxygenation of haemoglobin for 6 different layers of the injured skin. The parameters are presented as depth profiles. We analyzed and compared measurements of wounds of different degrees of damage and present the methodology and preliminary results. RESULTS: The depth profiles of the perfusion parameters show characteristic features and differences depending on the degree of damage. With Hyperspectral Imaging and the advanced data processing the perfusion characteristics of burn wounds can be visualized in more detail. Based on the analysis of this perfusion characteristics, a new and better reliable classification of burn degrees can be developed supporting the surgeon in the early selection of the optimal treatment.


Assuntos
Queimaduras/diagnóstico por imagem , Imagem de Perfusão/normas , Ferimentos e Lesões/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento Hiperespectral/métodos , Masculino , Microcirculação/fisiologia , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos , Ferimentos e Lesões/sangue
3.
J Intensive Care Med ; 35(10): 1032-1038, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30348044

RESUMO

OBJECTIVE: Computed tomography angiography is limited in the intensive care unit (ICU) due to renal insufficiency, hemodynamic instability, and difficulty transporting unstable patients. A portable ventilation/perfusion (V/Q) scan can be used. However, it is commonly believed that an abnormal chest radiograph can result in a nondiagnostic scan. In this retrospective study, we demonstrate that portable V/Q scans can be helpful in ruling in or out clinically significant pulmonary embolism (PE) despite an abnormal chest x-ray in the ICU. DESIGN: Two physicians conducted chart reviews and original V/Q reports. A staff radiologist, with 40 years of experience, rated chest x-ray abnormalities using predetermined criteria. SETTING: The study was conducted in the ICU. PATIENTS: The first 100 consecutive patients with suspected PE who underwent a portable V/Q scan. INTERVENTIONS: Those with a portable V/Q scan. RESULTS: A normal baseline chest radiograph was found in only 6% of patients. Fifty-three percent had moderate, 24% had severe, and 10% had very-severe radiographic abnormalities. Despite the abnormal x-rays, 88% of the V/Q scans were low probability for a PE despite an average abnormal radiograph rating of moderate. A high-probability V/Q for PE was diagnosed in 3% of the population despite chest x-ray ratings of moderate to severe. Six patients had their empiric anticoagulation discontinued after obtaining the results of the V/Q scan, and no anticoagulation was started for PE after a low-probability V/Q scan. CONCLUSION: Despite the large percentage of moderate-to-severe x-ray abnormalities, PE can still be diagnosed (high-probability scan) in the ICU with a portable V/Q scan. Although low-probability scans do not rule out acute PE, it appeared less likely that any patient with a low-probability V/Q scan had severe hypoxemia or hemodynamic instability due to a significant PE, which was useful to clinicians and allowed them to either stop or not start anticoagulation.


Assuntos
Imagem de Perfusão/estatística & dados numéricos , Testes Imediatos/estatística & dados numéricos , Embolia Pulmonar/diagnóstico por imagem , Cintilografia/estatística & dados numéricos , Transtornos Respiratórios/diagnóstico por imagem , Idoso , Cuidados Críticos/métodos , Cuidados Críticos/estatística & dados numéricos , Estado Terminal , Feminino , Humanos , Unidades de Terapia Intensiva , Pulmão/diagnóstico por imagem , Masculino , Imagem de Perfusão/métodos , Valor Preditivo dos Testes , Probabilidade , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/complicações , Radiografia , Cintilografia/métodos , Transtornos Respiratórios/etiologia , Estudos Retrospectivos
4.
Rofo ; 191(8): 725-731, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30703823

RESUMO

GOAL: In order to ensure high-quality cooperation between referring physicians and imaging services, it is important to assess the quality of imaging services as perceived by referring physicians. The present study aimed to develop and validate a questionnaire for referring physicians to assess the quality of outpatient diagnostic imaging services. MATERIALS & METHODS: The questionnaire was developed by discussing and modifying an existing instrument by the German Association of Surgeons. After qualitative pretesting, the instrument was tested with physicians referring to four outpatient diagnostic imaging services in Switzerland. The results were first assessed using descriptive statistics. The final instrument was tested for validity using the concept of known-groups validity. The hypothesis underlying this procedure was that physicians referring frequently to services estimated the quality of these services to be higher than physicians who referred less often to services. The differences in ratings were assessed using a one-sided two-sample Wilcoxon test. The final questionnaire was tested for internal consistency and reliability using Cronbach's Alpha. RESULTS: Results show a high level of satisfaction of referring physicians with the relevant services but also potential for quality improvement initiatives. The psychometric evaluation of the final questionnaire shows that it is a valid instrument, showing significant differences between the ratings of physicians referring with high and low frequency. Furthermore, the instrument proves to be consistent and reliable. CONCLUSION: The final instrument presents a valid, consistent and reliable option for assess the quality of outpatient diagnostic imaging services as perceived by referring physicians. Results can be used as a basis for quality improvement. KEY POINTS: · A newly developed questionnaire assesses the quality of outpatient diagnostic imaging services as perceived by referring physicians. The questionnaire was developed and tested in Switzerland.. · Psychometric evaluation showed the questionnaire to be a valid, consistent and reliable instrument.. · Results are of interest for imaging services as well as for initiatives encompassing several services.. CITATION FORMAT: · Jossen M, Valeri F, Heilmaier C et al. Referring Physicians Assess the Quality of Outpatient Diagnostic Imaging Services: Development and Psychometric Evaluation of a Questionnaire. Fortschr Röntgenstr 2019; 191: 725 - 731.


Assuntos
Imagem de Perfusão/estatística & dados numéricos , Imagem de Perfusão/normas , Psicometria/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/normas , Inquéritos e Questionários/estatística & dados numéricos , Inquéritos e Questionários/normas , Assistência Ambulatorial/normas , Assistência Ambulatorial/estatística & dados numéricos , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/normas , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Diagnóstico Diferencial , Humanos , Aumento da Imagem/métodos , Aumento da Imagem/normas , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Lesões Pré-Cancerosas/diagnóstico por imagem , Lesões Pré-Cancerosas/fisiopatologia , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Encaminhamento e Consulta/normas , Encaminhamento e Consulta/estatística & dados numéricos , Fluxo Sanguíneo Regional/fisiologia
5.
Dis Esophagus ; 31(6)2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29701760

RESUMO

Anastomotic leakage is one of the most severe complications after esophageal resection with gastric tube reconstruction. Impaired perfusion of the gastric fundus is seen as the main contributing factor for this complication. Optical modalities show potential in recognizing compromised perfusion in real time, when ischemia is still reversible. This review provides an overview of optical techniques with the aim to evaluate the (1) quantitative measurement of change in perfusion in gastric tube reconstruction and (2) to test which parameters are the most predictive for anastomotic leakage.A Pubmed, MEDLINE, and Embase search was performed and articles on laser Doppler flowmetry (LDF), near-infrared spectroscopy (NIRS), laser speckle contrast imaging (LSCI), fluorescence imaging (FI), sidestream darkfield microscopy (SDF), and optical coherence tomography (OCT) regarding blood flow in gastric tube surgery were reviewed. Two independent reviewers critically appraised articles and extracted the data: Primary outcome was quantitative measure of perfusion change; secondary outcome was successful prediction of necrosis or anastomotic leakage by measured perfusion parameters.Thirty-three articles (including 973 patients and 73 animals) were selected for data extraction, quality assessment, and risk of bias (QUADAS-2). LDF, NIRS, LSCI, and FI were investigated in gastric tube surgery; all had a medium level of evidence. IDEAL stage ranges from 1 to 3. Most articles were found on LDF (n = 12), which is able to measure perfusion in arbitrary perfusion units with a significant lower amount in tissue with necrosis development and on FI (n = 12). With FI blood flow routes could be observed and flow was qualitative evaluated in rapid, slow, or low flow. NIRS uses mucosal oxygen saturation and hemoglobin concentration as perfusion parameters. With LSCI, a decrease of perfusion units is observed toward the gastric fundus intraoperatively. The perfusion units (LDF, LSCI), although arbitrary and not absolute values, and low flow or length of demarcation to the anastomosis (FI) both seem predictive values for necrosis intraoperatively. SDF and OCT are able to measure microvascular flow, intraoperative prediction of necrosis is not yet described.Optical techniques aim to improve perfusion monitoring by real-time, high-resolution, and high-contrast measurements and could therefore be valuable in intraoperative perfusion mapping. LDF and LSCI use perfusion units, and are therefore subjective in interpretation. FI visualizes influx directly, but needs a quantitative parameter for interpretation during surgery.


Assuntos
Fístula Anastomótica/diagnóstico por imagem , Esofagectomia/efeitos adversos , Fundo Gástrico/diagnóstico por imagem , Imagem de Perfusão/métodos , Estômago/cirurgia , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/etiologia , Meios de Contraste , Angiofluoresceinografia/métodos , Angiofluoresceinografia/estatística & dados numéricos , Fundo Gástrico/irrigação sanguínea , Humanos , Fluxometria por Laser-Doppler/métodos , Fluxometria por Laser-Doppler/estatística & dados numéricos , Microcirculação , Microscopia/métodos , Microscopia/estatística & dados numéricos , Imagem de Perfusão/estatística & dados numéricos , Período Pós-Operatório , Valores de Referência , Fluxo Sanguíneo Regional , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Espectroscopia de Luz Próxima ao Infravermelho/estatística & dados numéricos , Tomografia de Coerência Óptica/métodos , Tomografia de Coerência Óptica/estatística & dados numéricos
6.
Tuberk Toraks ; 65(2): 106-111, 2017 Jun.
Artigo em Turco | MEDLINE | ID: mdl-28990889

RESUMO

INTRODUCTION: Lung volume reduction coil (LVRC) is a new treatment method which exercise capacities among the patients with severe emphysema. In order to determine the emphysema distribution before LVRC treatment, we examined the contribution of combination of the high resolution computed tomography (HRCT) of the lung and the quantitative perfusion scintigraphy to the efficiency of the procedure. MATERIALS AND METHODS: The study was conducted retrospectively. The densitometry analysis and scores of emphysema areas of the patients who were found suitable for LVRC treatment in HRCT were determined. Before the procedure, the quantitative lung perfusion scintigraphies were taken. Lobes which had high emphysema score and in which a decrease perfusion was observed in quantitative perfusion scintigraphy were determined as treatment areas. RESULT: A total of 22 patients were treated. In HRCT it was observed that perfusion decreased in lobes in which the emphysema damage scoring was high. A significant statistical difference was found between pre-and post- procedure measurements in terms of FEV1, RV, and TLC (p<0.05). In six minute walk test, a statistically significant difference was found as 45.4 ± 23.9 m (p= 0.000). No significant difference was determined between perfusion ratios before the procedure and perfusion ratios after the procedure. CONCLUSIONS: The quantitative perfusion scintigraphy taken before LVRC treatment in severe emphysema patients guides to determine the target lobe for treatment and makes contribution to the efficiency of the procedure.


Assuntos
Broncoscopia/métodos , Imagem de Perfusão/estatística & dados numéricos , Pneumonectomia/métodos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
7.
J Neurointerv Surg ; 9(10): 1012-1016, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28899932

RESUMO

BACKGROUND: Variability in imaging protocols and techniques has resulted in a lack of consensus regarding the incorporation of perfusion imaging into stroke triage and treatment. The objective of our study was to evaluate the available scientific evidence regarding the utility of perfusion imaging in determining treatment eligibility in patients with acute stroke and in predicting their clinical outcome. METHODS: We performed a systematic review of the literature using PubMed, Web of Science, and Cochrane Library focusing on themes of medical imaging, stroke, treatment, and outcome (CRD42016037817). We included randomized controlled trials, cohort studies, and case-controlled studies published from 2011 to 2016. Two independent reviewers conducted the study appraisal, data abstraction, and quality assessments of the studies. RESULTS: Our literature search yielded 13 studies that met our inclusion criteria. In total, 994 patients were treated with the aid of perfusion imaging compared with 1819 patients treated with standard care. In the intervention group 51.1% of patients had a favorable outcome at 3 months compared with 45.6% of patients in the control group (p=0.06). Subgroup analysis of studies that used multimodal therapy (IV tissue plasminogen activator, endovascular thrombectomy) showed a significant benefit of perfusion imaging (OR 1.89, 95% CI 1.43 to 2.51, p<0.01). CONCLUSIONS: Perfusion imaging may represent a complementary tool to standard radiographic assessment in enhancing patient selection for reperfusion therapy, with a subset of patients having up to 1.9 times the odds of achieving independent functional status at 3 months. This is particularly important as patients selected based on perfusion status often included individuals who did not meet the current treatment eligibility criteria.


Assuntos
Imagem de Perfusão/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Estudos de Casos e Controles , Estudos de Coortes , Terapia Combinada/métodos , Procedimentos Endovasculares/métodos , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Seleção de Pacientes , Ensaios Clínicos Controlados Aleatórios como Assunto , Trombectomia/métodos , Terapia Trombolítica/métodos , Resultado do Tratamento
8.
MAGMA ; 30(6): 609-620, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28744673

RESUMO

OBJECTIVE: This research utilizes magnetic resonance angiography (MRA) to identify arterial locations during the parametric evaluation of concentration time curves (CTCs), and to prevent shape distortions in arterial input function (AIF). MATERIALS AND METHODS: We carried out cluster analysis with the CTC parameters of voxels located within and around the middle cerebral artery (MCA). Through MRA, we located voxels that meet the AIF criteria and those with distorted CTCs. To minimize partial volume effect, we re-scaled the time integral of CTCs by the time integral of venous output function (VOF). We calculated the steady-state value to area under curve ratio (SS:AUC) of VOF and used it as a reference in selecting AIF. CTCs close to this reference value (selected AIF) and those far from it were used (eliminated AIF) to compute cerebral blood flow (CBF). RESULTS: Eliminated AIFs were found to be either on or anterior to MCA, whereas selected AIFs were located superior, inferior, posterior, or anterior to MCA. If the SS:AUC of AIF was far from the reference value, CBF was either under- or over-estimated by a maximum of 41.1 ± 14.3 and 36.6 ± 19.2%, respectively. CONCLUSION: MRA enables excluding voxels on the MCA during cluster analysis, and avoiding the risk of shape distortions.


Assuntos
Circulação Cerebrovascular/fisiologia , Angiografia por Ressonância Magnética/métodos , Artéria Cerebral Média/diagnóstico por imagem , Imagem de Perfusão/métodos , Neoplasias Encefálicas/irrigação sanguínea , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/fisiopatologia , Análise por Conglomerados , Meios de Contraste , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética/estatística & dados numéricos , Artéria Cerebral Média/fisiologia , Imagem de Perfusão/estatística & dados numéricos
9.
MAGMA ; 30(6): 545-554, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28608327

RESUMO

OBJECTIVES: The objectives were to investigate the diffusional kurtosis imaging (DKI) incorporation into the intravoxel incoherent motion (IVIM) model for measurements of cerebral hypoperfusion in healthy subjects. MATERIALS AND METHODS: Eight healthy subjects underwent a hyperventilation challenge with a 4-min diffusion weighted imaging protocol, using 8 b values chosen with the Cramer-Rao Lower Bound optimization approach. Four regions of interest in gray matter (GM) were analyzed with the DKI-IVIM model and the bi-exponential IVIM model, for normoventilation and hyperventilation conditions. RESULTS: A significant reduction in the perfusion fraction (f) and in the product fD* of the perfusion fraction with the pseudodiffusion coefficient (D*) was found with the DKI-IVIM model, during the hyperventilation challenge. In the cerebellum GM, the percentage changes were f: -43.7 ± 40.1, p = 0.011 and fD*: -50.6 ± 32.1, p = 0.011; in thalamus GM, f: -47.7 ± 34.7, p = 0.012 and fD*: -47.2 ± 48.7, p = 0.040. In comparison, using the bi-exponential IVIM model, only a significant decrease in the parameter fD* was observed for the same regions of interest. In frontal-GM and posterior-GM, the reduction in f and fD* did not reach statistical significance, either with DKI-IVIM or the bi-exponential IVIM model. CONCLUSION: When compared to the bi-exponential IVIM model, the DKI-IVIM model displays a higher sensitivity to detect changes in perfusion induced by the hyperventilation condition.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Hiperventilação/diagnóstico por imagem , Adulto , Volume Sanguíneo Cerebral , Circulação Cerebrovascular , Imagem de Difusão por Ressonância Magnética/estatística & dados numéricos , Imagem Ecoplanar/métodos , Imagem Ecoplanar/estatística & dados numéricos , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Movimento (Física) , Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos
10.
Nucl Med Commun ; 38(2): 135-140, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27977536

RESUMO

OBJECTIVE: This study aims to compare the incidence of ventilation/perfusion (V/Q) scans interpreted as indeterminate for the diagnosis of pulmonary embolism (PE) using single-photon emission computed tomography (SPECT) versus planar scintigraphy and to consider the effect of variable interpretation of single subsegmental V/Q mismatch (SSM). METHODS: A total of 1300 consecutive V/Q scans were retrospectively reviewed. After exclusion and matching for age and sex, 542 SPECT and 589 planar scans were included in the analysis. European Association of Nuclear Medicine guidelines were used to interpret the V/Q scans, initially interpreting SSM as negative scans. Patients with SSM were followed up for 3 months and further imaging for PE was collected. RESULTS: Indeterminate scans were significantly fewer in the SPECT than the planar group on the basis of the initial report (7.7 vs. 12.2%, P<0.05). This is irrespective of classification of SSM as a negative scan (4.6 vs. 12.1%, P<0.0001) or an indeterminate scan (8.3 vs. 12.2%, P<0.05). Of the 21 patients who had SSM, 19 underwent computer tomography pulmonary angiogram and embolism was found in one patient. None of these patients died at the 3-month follow-up. CONCLUSION: V/Q SPECT has greater diagnostic certainty of PE, with a 41% reduction in an indeterminate scan compared with planar scintigraphy. This is irrespective of the clinician's interpretation of SSM as negative or intermediate probability. Patients with SSM would not require further computer tomography pulmonary angiogram imaging.


Assuntos
Imagem de Perfusão/métodos , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/estatística & dados numéricos , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Relação Ventilação-Perfusão , Adulto Jovem
11.
Acute Med ; 15(2): 58-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27441306

RESUMO

This was a retrospective review of five years' data relating to patients referred to the Acute Medical Unit (AMU) of a large teaching hospital with suspected Pulmonary Embolism (PE) during pregnancy or 6 weeks postpartum. During this period, 210 patients in this group underwent half-dose perfusion scanning as investigation for possible PE and were managed via our ambulatory pathway. Pulmonary embolism was diagnosed in 5.2% of patients compared to 18% of non-pregnant patients identified in a previous audit. Half-dose Q scanning enabled exclusion of PE in almost 90% of patients without the need for further imaging. A new local pathway for the investigation and management of PE during pregnancy has now been developed.


Assuntos
Procedimentos Clínicos/organização & administração , Imagem de Perfusão , Complicações Cardiovasculares na Gravidez , Transtornos Puerperais , Embolia Pulmonar , Adulto , Assistência Ambulatorial/métodos , Relação Dose-Resposta a Droga , Feminino , Hospitais de Ensino , Humanos , Pulmão/diagnóstico por imagem , Imagem de Perfusão/métodos , Imagem de Perfusão/estatística & dados numéricos , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Transtornos Puerperais/diagnóstico , Transtornos Puerperais/etiologia , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/etiologia , Compostos Radiofarmacêuticos/farmacologia , Estudos Retrospectivos , Reino Unido
12.
Microvasc Res ; 107: 6-16, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27131831

RESUMO

Laser speckle contrast imaging (LSCI) provides a noninvasive and cost effective solution for in vivo monitoring of blood flow. So far, most of the researches consider changes in speckle pattern (i.e. correlation time of speckle intensity fluctuation), account for relative change in blood flow during abnormal conditions. This paper introduces an application of LSCI for monitoring wound progression and characterization of cutaneous wound regions on mice model. Speckle images are captured on a tumor wound region at mice leg in periodic interval. Initially, raw speckle images are converted to their corresponding contrast images. Functional characterization begins with first segmenting the affected area using k-means clustering, taking wavelet energies in a local region as feature set. In the next stage, different regions in wound bed are clustered based on progressive and non-progressive nature of tissue properties. Changes in contrast due to heterogeneity in tissue structure and functionality are modeled using LSCI speckle statistics. Final characterization is achieved through supervised learning of these speckle statistics using support vector machine. On cross evaluation with mice model experiment, the proposed approach classifies the progressive and non-progressive wound regions with an average sensitivity of 96.18%, 97.62% and average specificity of 97.24%, 96.42% respectively. The clinical information yield with this approach is validated with the conventional immunohistochemistry result of wound to justify the ability of LSCI for in vivo, noninvasive and periodic assessment of wounds.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Fluxometria por Laser-Doppler/métodos , Microcirculação , Imagem de Perfusão/métodos , Sarcoma 180/irrigação sanguínea , Sarcoma 180/diagnóstico por imagem , Pele/irrigação sanguínea , Aprendizado de Máquina Supervisionado , Animais , Área Sob a Curva , Velocidade do Fluxo Sanguíneo , Interpretação Estatística de Dados , Modelos Animais de Doenças , Imuno-Histoquímica , Fluxometria por Laser-Doppler/estatística & dados numéricos , Masculino , Camundongos , Imagem de Perfusão/estatística & dados numéricos , Valor Preditivo dos Testes , Curva ROC , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Sarcoma 180/patologia , Pele/patologia , Fatores de Tempo , Cicatrização
13.
Microvasc Res ; 107: 46-50, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27154269

RESUMO

In this work, we report about q statistics concept to improve the performance of generalized differences algorithm based on intensity histogram for imaging functional blood vessel structures in a rodent window chamber of a mice. The method uses the dynamic speckle signals obtained by transilluminating the rodent window chamber to create activity maps of vasculatures. The proposed method of generalized differences with q statistics (GDq) is very sensitive to the values of defined parameters such as: camera exposure time, the q value and the camera frame number. Appropriate choice of q values enhances the visibility (contrast) of functional blood vessels but at the same time without sacrificing the spatial resolution, which is of utmost importance for in-vivo vascular imaging.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Fluxometria por Laser-Doppler , Imagem de Perfusão/métodos , Algoritmos , Animais , Velocidade do Fluxo Sanguíneo , Vasos Sanguíneos/fisiologia , Interpretação Estatística de Dados , Fluxometria por Laser-Doppler/estatística & dados numéricos , Camundongos , Imagem de Perfusão/estatística & dados numéricos , Valor Preditivo dos Testes , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Gravação em Vídeo
14.
World Neurosurg ; 90: 66-75, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26906896

RESUMO

OBJECTIVE: The purposes of this study were to review the cerebrovascular events (CVE) during pregnancy and puerperium in adults with moyamoya disease (MMD) and to evaluate its risk factors. METHODS: We reviewed electronic medical records on 141 pregnancies in 71 women diagnosed with MMD and this study included only 27 pregnancies (23 patients) diagnosed with MMD before pregnancy. Basal and acetazolamide-stress brain perfusion single-photon emission computed tomography (SPECT) was conducted for 40 hemispheres in 21 pregnancies within 1 year of the gestational period, ranging from 22 months before delivery to 12 months after delivery for evaluation of the hemodynamic status of the patients to devise the MMD treatment strategy. RESULTS: Twelve pregnancies (44.4%) showed CVE during pregnancy or puerperium in the group diagnosed with MMD before pregnancy. All the 12 CVE were ischemic, without any hemorrhagic events. A decreased cerebral vascular reserve capacity (CVRC) on stress SPECT was observed in 25 (62.5%) of the 40 hemispheres, and 18 of these 25 hemispheres showed TIA. In contrast, only 2 of 15 hemispheres which revealed normal CVRC on stress SPECT showed TIA. Overall, a decreased CVRC on stress SPECT imaging was statistically associated with development of CVE (P < 0.001). Furthermore, the clinical type of MMD was also regarded as predictive factor for CVE in this study. Especially, ischemic type MMD revealed a statistical association with the development of CVE (P = 0.014, odds ratio = 16.50). CONCLUSIONS: Assessment of cerebral hemodynamic status with stress SPECT may predict CVE during pregnancy and puerperium.


Assuntos
Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/epidemiologia , Doença de Moyamoya/diagnóstico por imagem , Doença de Moyamoya/epidemiologia , Complicações na Gravidez/diagnóstico por imagem , Complicações na Gravidez/epidemiologia , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Adulto , Causalidade , Comorbidade , Feminino , Humanos , Incidência , Imagem de Perfusão/estatística & dados numéricos , Período Pós-Parto , Gravidez , Reprodutibilidade dos Testes , República da Coreia/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Adulto Jovem
15.
Zhong Nan Da Xue Xue Bao Yi Xue Ban ; 41(12): 1270-1277, 2016 Dec 28.
Artigo em Chinês | MEDLINE | ID: mdl-28070038

RESUMO

OBJECTIVE: To investigate the correlations among total liver CT perfusion parameters, unpaired arteries (UAs) and microvessel area (MVA) in a rabbit liver VX2 tumor model, and to learn the tumoral angiogenesis condition and the mechanisms for perfusion imaging.
 Methods: Rabbits with or without the inoculated VX2 tumor in the liver underwent total liver CT perfusion imaging 2 weeks after the operation. Perfusion parameters included blood flow (BF), blood volume (BV), arterial liver perfusion (ALP), portal liver perfusion (PVP), hepatic perfusion index (HPI) for the tumor rim and the surrounding liver tissue. After the examination, the UAs and MVA of tumor tissues were obtained by immunohistochemical staining. The differences of perfusion parameters between the vital tumor rim and the surrounding liver tissue were compared. The correlations among perfusion parameters, UAs and MVA were analyzed.
 Results: There was significant difference between the CT perfusion parameters at the tumor rim and the surrounding liver tissue or liver tissue of the control group (P<0.05), but there was no significant difference between the perfusion parameters at the surrounding liver tissues of the experimental group and the control (P>0.05). There was positive correlation between UAs and MVA. UAs and MVA were positively correlated with BF, ALP and BV at the tumor rim. UAs and MVA were negatively correlated with PVP. HPI positively correlated with UAs, but it was not correlated with MVA.
 Conclusion: Total liver CT perfusion can provide quantitative information to evaluate the artery and portal vein perfusion of liver VX2 tumor, and to assess the degree of tumor angiogenesis.


Assuntos
Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Imagem de Perfusão/estatística & dados numéricos , Animais , Artérias/diagnóstico por imagem , Volume Sanguíneo , Carcinoma , Imuno-Histoquímica , Circulação Hepática , Microvasos/diagnóstico por imagem , Transplante de Neoplasias , Neoplasias de Células Escamosas , Sistema Porta/diagnóstico por imagem , Coelhos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
16.
Neuroradiology ; 57(12): 1219-25, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26337766

RESUMO

INTRODUCTION: Intravenous recombinant tissue plasminogen activator (IV-rtPA) is given in acute ischemic stroke patients to achieve reperfusion. Hemorrhagic transformation (HT) is a serious complication of IV-rtPA treatment and related to blood-brain barrier (BBB) injury. It is unclear whether HT occurs secondary to reperfusion in combination with ischemic BBB injury or is caused by the negative effect of IV-rtPA on BBB integrity. The aim of this study was to establish the association between reperfusion and the occurrence of HT. METHODS: From the DUST study, patients were selected with admission and follow-up non-contrast CT (NCCT) and CT perfusion (CTP) imaging, and a perfusion deficit in the middle cerebral artery territory on admission. Reperfusion was categorized qualitatively as reperfusion or no-reperfusion by visual comparison of admission and follow-up CTP. Occurrence of HT was assessed on follow-up NCCT. The association between reperfusion and occurrence of HT on follow-up was estimated by calculating odds ratios (ORs) and 95 % confidence intervals (CIs) with additional stratification for IV-rtPA treatment. RESULTS: Inclusion criteria were met in 299 patients. There was no significant association between reperfusion and HT (OR 1.2 95%CI 0.5-3.1). In patients treated with IV-rtPA (n = 203), the OR was 1.3 (95%CI 0.4-4.0), and in patients not treated with IV-rtPA (n = 96), the OR was 0.8 (95%CI 0.1-4.5). HT occurred in 14 % of the IV-rtPA patients and in 7 % of patients without IV-rtPA (95%CI of difference -1 to 14 %). CONCLUSION: Our results suggest that the increased risk of HT after acute ischemic stroke treatment is not dependent on the reperfusion status.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/epidemiologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Ativador de Plasminogênio Tecidual/administração & dosagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Idoso , Angiografia Cerebral/estatística & dados numéricos , Revascularização Cerebral/estatística & dados numéricos , Comorbidade , Progressão da Doença , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Imagem de Perfusão/estatística & dados numéricos , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Resultado do Tratamento
17.
Nuklearmedizin ; 54(5): 217-22, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26392088

RESUMO

UNLABELLED: V/P-SPECT is a sensitive and specific procedure for the detection or exclusion of pulmonary embolism. It is important to conform to the guidelines in order to obtain reliable results. The sequence usually starts with the ventilation, followed by the perfusion scan. According to the current guidelines the count rate of the second study should be at least 3 times that of the first study. It is not always easy to meet this requirement, particularly since the deposed quantity of ventilation activity is not well known. The aim was therefore to analyse data from a multicentre survey to determine whether this essential precondition was strictly met. METHODS: In a multicentre survey 48 tertiary hospitals were asked to submit projections of all V/P-SPECT studies performed in January 2014. In total, 286 complete data sets from 16 institutions could be evaluated. First, the count rates of the first projections from the V-studies were subtracted from those of the P-studies. The resulting count rates in the first SPECT projections were then divided to calculate the activity ratios between the pure perfusion and ventilation scans (P/V-ratio at least 3 according to the guidelines). RESULTS: The range of the P/V ratio was 0.57-78.71, the mean P/V ratio was 6.94 ± 9.56. For 71 of the 286 external V/P studies (about 25%) the P/V ratio was < 3, in 23 studies (about 8%) the ratio failed to even reach the factor 2. CONCLUSIONS: An activity ratio of 3 between the perfusion and ventilation scan was not reached in about 25% of the 286 V/P studies (in around 8% the P/V ratio was <2), so that V/P studies were performed inadequately in a considerable number of procedures. Controlling the count rate increase during the perfusion tracer application (e. g. by handheld monitor) is therefore essential to avoid insufficient data.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem de Perfusão/estatística & dados numéricos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Relação Ventilação-Perfusão , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Imagem de Perfusão/métodos , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos
18.
Thromb Res ; 134(6): 1182-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25312342

RESUMO

PURPOSE: The purpose of this investigation was to determine the prevalence of silent pulmonary embolism (PE) in patients with deep venous thrombosis (DVT) limited to the calf veins. METHODS: This is a systematic review. We attempted to identify all published investigations that reported the prevalence of silent PE in patients with infrapopliteal DVT. Studies were identified by searching PubMed through January 2014. The search was augmented by manually reviewing the references in all original articles and in reviews. RESULTS: The prevalence of silent PE in patients with DVT limited to the calf veins was described in 6 investigations. Pooled data showed a prevalence of 24 of 183 (13.1%) (95% CI 8.9-18.8%). CONCLUSION: Silent PE in patients with DVT limited to the calf veins is not rare. Imaging at the time of diagnosis of calf vein DVT, typically with a perfusion scan alone, may be useful, but there is an economic cost and exposure to radiation.


Assuntos
Imagem de Perfusão/estatística & dados numéricos , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/epidemiologia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Causalidade , Comorbidade , Humanos , Incidência , Radiografia , Fatores de Risco
19.
Stroke ; 45(4): 1029-34, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24569815

RESUMO

BACKGROUND AND PURPOSE: Our objective was to study nationwide utilization trends of computed tomographic (CT) angiogram (CTA) and CT perfusion (CTP) in acute ischemic stroke and particularly in the context of use of reperfusion therapies. METHODS: We reviewed the Premier Perspective Database for ischemic stroke-related hospitalizations of adult patients during a 5-year period, 2006 to 2010. Use of multimodal CT-based imaging and reperfusion therapies was determined through the procedure and billing codes. Logistic regression was used to identify predictors of utilization of imaging studies and reperfusion treatments. RESULTS: An increasing proportion of ischemic strokes received CTA each year: 3.8% in 2006, 5.6% in 2007, 6.5% in 2008, 7.5% in 2009, and 9.1% in 2010 (P<0.0001). The proportion of acute strokes that were imaged with CTP imaging also increased each year: 0.05% in 2006, 0.05% in 2007, 0.9% in 2008, 2.2% in 2009, and 2.9% in 2010 (P<0.0001). Reperfusion treatment was more common among those who were imaged with CTA (13.0%) and CTP (17.6%) compared with those with CT head alone (4.0%; P<0.0001). Specifically, higher rates of recombinant tissue-type plasminogen activator were observed in CTA (10.2%) and CTP (11.4%) compared with those with CT head alone (3.8%; P<0.0001). Similarly, higher rates of mechanical embolectomy were observed in CTA (2.8%) and CTP (6.3%) compared with those with CT head alone (0.2%; P<0.0001). CONCLUSIONS: There was a marked increase in the rate of CTA and CTP studies in setting of acute ischemic stroke from 2006 to 2010, and both modalities were associated with increased reperfusion therapy use.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Angiografia Cerebral/estatística & dados numéricos , Imagem de Perfusão/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Doença Aguda , Idoso , Isquemia Encefálica/tratamento farmacológico , Bases de Dados Factuais , Feminino , Fibrinolíticos/uso terapêutico , Hospitais Rurais/estatística & dados numéricos , Hospitais de Ensino/estatística & dados numéricos , Hospitais Urbanos/estatística & dados numéricos , Humanos , Modelos Logísticos , Masculino , Acidente Vascular Cerebral/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Estados Unidos
20.
Eur J Radiol ; 82(12): e894-900, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24094644

RESUMO

OBJECTIVE: To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients. MATERIALS AND METHODS: 173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume. RESULTS: Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p<0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p=0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = -0.22, -0.24, -0.24, all p<0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = -0.40, all p<0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p<0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed. CONCLUSIONS: dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/fisiopatologia , Imagem de Perfusão/estatística & dados numéricos , Circulação Pulmonar , Idoso , Idoso de 80 Anos ou mais , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA