Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
J Vasc Interv Radiol ; 35(9): 1397-1403.e2, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38825180

RESUMO

The purpose of this study was to evaluate the contemporary trends in inferior vena cava (IVC) filter utilization in the inpatient setting following the U.S. Food and Drug Administration (FDA) safety communications and compare those trends in relation to incidence of hospital admissions involving venous thromboembolism (VTE). The National Inpatient Sample was queried between 2005 and 2019. There was an increasing trend in the utilization of IVC filters between 2005 and 2010 (P < .01). Following the FDA communication in 2010, this reversed to a decreasing trend (P < .001), which persisted following the second FDA communication in 2014, although there was no significant change in the rate of decline (P = .67). Throughout the study period, the proportion of IVC filters placed in patients with VTE increased from 70.8% to 82.2%.


Assuntos
Bases de Dados Factuais , Pacientes Internados , United States Food and Drug Administration , Filtros de Veia Cava , Tromboembolia Venosa , Humanos , Filtros de Veia Cava/tendências , Estados Unidos/epidemiologia , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/prevenção & controle , Fatores de Tempo , Padrões de Prática Médica/tendências , Masculino , Feminino , Implantação de Prótese/tendências , Implantação de Prótese/instrumentação , Estudos Retrospectivos , Pessoa de Meia-Idade , Incidência , Idoso
2.
Andrology ; 12(6): 1209-1214, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38228573

RESUMO

INTRODUCTION: Testicular tumors are the most common malignancies in young adults and their incidence is growing. The implantation of a testicular prosthesis, for example, during orchiectomy is a standard procedure but its frequency in Germany is unknown. This study aims to analyze trends of testicular prosthesis implantation in recent years in Germany. MATERIAL AND METHODS: The nationwide German hospital billing database and the German hospital quality reports from 2006 to 2021 were studied. RESULTS: A total of 12,753 surgical procedures with implantation of testicular prosthesis and 1,244 procedures with testicular prosthesis explantation were included. Testicular prosthesis implantation increased in total from 699 cases in 2006 to 870 cases in 2020 (+11.4 cases/year; p < 0.001). The share of implantation of testicular prosthesis due to testicular tumor decreased from 72.6% in 2006 to 67.5% in 2020 (p < 0.001). The share of implantation due to gender affirming surgery increased from 6.8% in 2006 to 23.3% in 2020 (p < 0.001). The share of implantation due to testicular atrophy decreased from 11.4% in 2006 to 3.4% in 2020 (p < 0.001). Simultaneous implantation of testicular prosthesis during orchiectomy for testicular cancer increased from 7.8% in 2006 to 11.4% in 2020 (p < 0.001). In 2006, 146 hospitals (85%) performed < 5 testicular prosthesis implantation, while 20 hospitals (12%) performed 5-15 implantation procedures and 6 hospitals (3%) performed > 15 testicular implantation surgeries. In 2021, 115 hospitals (72%) performed < 5 testicular prosthesis implantation, while 39 hospitals (25%) performed 5-15 implantation procedures and 5 hospitals (3%) performed > 15 testicular implantation surgeries. CONCLUSION: This study shows that implantation of testicular prostheses is steadily increasing. Explantation rates are low. Besides testicular cancer transgender surgeries were the main driver for increasing case numbers in recent years.


Assuntos
Orquiectomia , Neoplasias Testiculares , Humanos , Masculino , Alemanha/epidemiologia , Neoplasias Testiculares/cirurgia , Neoplasias Testiculares/epidemiologia , Orquiectomia/tendências , Adulto , Implantação de Prótese/tendências , Próteses e Implantes/tendências , Adulto Jovem , Cirurgia de Readequação Sexual/tendências , Testículo/cirurgia
3.
J Gynecol Obstet Hum Reprod ; 51(1): 102234, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34571197

RESUMO

Native tissue cystocele repair has been the cornerstone of prolapse surgery, especially since the learned societies warned clinicians and patients about serious mesh related complications and recommend a vaginal route without prosthesis in first intention. Surgical techniques mainly consist in anterior colporraphy, vaginal patch plastron and para vaginal repair. However, in case of vaginal patch plastron, the vagina left in contact with the bladder is a material of much better quality than colporraphy alone. The multiplication of native tissues, generating post-operative fibrosis, associated with anchorage on a strong ligamentous structure, allows to expect better outcomes compared to anterior colporraphy. Indeed, vaginal plastron corrects median cystoceles with a vaginal strip as well as lateral cystoceles thanks to bilateral paravaginal suspension. Thereby, vaginal patch plastron appears to be a good compromise between the 3 autologous techniques with median and paralateral repair We aimed to describe the surgical technique of the vaginal patch plastron for vaginal native tissue repair for cystocele.


Assuntos
Cistocele/cirurgia , Implantação de Prótese/instrumentação , Telas Cirúrgicas/normas , Adulto , Cistocele/complicações , Feminino , Humanos , Pessoa de Meia-Idade , Prolapso de Órgão Pélvico/cirurgia , Implantação de Prótese/métodos , Implantação de Prótese/tendências
5.
Bone Joint J ; 103-B(3): 430-439, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33641410

RESUMO

Upper limb amputations, ranging from transhumeral to partial hand, can be devastating for patients, their families, and society. Modern paradigm shifts have focused on reconstructive options after upper extremity limb loss, rather than considering the amputation an ablative procedure. Surgical advancements such as targeted muscle reinnervation and regenerative peripheral nerve interface, in combination with technological development of modern prosthetics, have expanded options for patients after amputation. In the near future, advances such as osseointegration, implantable myoelectric sensors, and implantable nerve cuffs may become more widely used and may expand the options for prosthetic integration, myoelectric signal detection, and restoration of sensation. This review summarizes the current advancements in surgical techniques and prosthetics for upper limb amputees. Cite this article: Bone Joint J 2021;103-B(3):430-439.


Assuntos
Amputados/reabilitação , Membros Artificiais/tendências , Desenho de Prótese/tendências , Implantação de Prótese/tendências , Extremidade Superior/cirurgia , Amputação Cirúrgica , Cotos de Amputação/inervação , Humanos , Osseointegração , Sensação , Extremidade Superior/inervação
6.
Europace ; 23(3): 456-463, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33595062

RESUMO

AIMS: During the COVID-19 pandemic, concern regarding its effect on the management of non-communicable diseases has been raised. However, there are no data on the impact on cardiac implantable electronic devices (CIED) implantation rates. We aimed to determine the impact of SARS-CoV2 on the monthly incidence rates and type of pacemaker (PM) and implantable cardiac defibrillator (ICD) implantations in Catalonia before and after the declaration of the state of alarm in Spain on 14 March 2020. METHODS AND RESULTS: Data on new CIED implantations for 2017-20 were prospectively collected by nine hospitals in Catalonia. A mixed model with random intercepts corrected for time was used to estimate the change in monthly CIED implantations. Compared to the pre-COVID-19 period, an absolute decrease of 56.5% was observed (54.7% in PM and 63.7% in ICD) in CIED implantation rates. Total CIED implantations for 2017-19 and January and February 2020 was 250/month (>195 PM and >55 ICD), decreasing to 207 (161 PM and 46 ICD) in March and 131 (108 PM and 23 ICD) in April 2020. In April 2020, there was a significant fall of 185.25 CIED implantations compared to 2018 [95% confidence interval (CI) 129.6-240.9; P < 0.001] and of 188 CIED compared to 2019 (95% CI 132.3-243.7; P < 0.001). No significant differences in the type of PM or ICD were observed, nor in the indication for primary or secondary prevention. CONCLUSIONS: During the first wave of the COVID-19 pandemic, a substantial decrease in CIED implantations was observed in Catalonia. Our findings call for measures to avoid long-term social impact.


Assuntos
COVID-19 , Desfibriladores Implantáveis/tendências , Marca-Passo Artificial/tendências , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Humanos , Segurança do Paciente , Estudos Prospectivos , Implantação de Prótese/instrumentação , Espanha , Fatores de Tempo
7.
J Vasc Surg Venous Lymphat Disord ; 9(5): 1093-1098, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33482377

RESUMO

In response to the pandemic, an abrupt pivot of Vascular Quality Initiative physician members away from standard clinical practice to a restrictive phase of emergent and urgent vascular procedures occurred. The Society for Vascular Surgery Patient Safety Organization queried both data managers and physicians in May 2020. Approximately three-fourths (74%) of physicians adopted restrictive operating policies for urgent and emergent cases only, whereas one-half proceeded with "time sensitive" elective cases as urgent. Data manager case entry was negatively affected by both low case volumes and staffing due to reassignment or furlough. Venous registry volumes were reduced fivefold in the first quarter of 2020 compared with a similar period in 2019. The consequences of delaying vascular procedures for ambulatory venous practice remain unknown with increased morbidity likely. Challenges to determine venous thromboembolism mortality impact exist given difficulty in verifying "in home and extended care facility" deaths. Further ramifications of a pandemic shutdown will likely be amplified if postponement of elective vascular care extends beyond a short window of time. It will be important to monitor disease progression and case severity as a result of policy shifts adopted locally in response to pandemic surges.


Assuntos
COVID-19 , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Cirurgiões/tendências , Varizes/terapia , Procedimentos Cirúrgicos Vasculares/tendências , Filtros de Veia Cava/tendências , Tromboembolia Venosa/terapia , Procedimentos Cirúrgicos Eletivos/tendências , Pesquisas sobre Atenção à Saúde , Humanos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Varizes/diagnóstico por imagem , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Tromboembolia Venosa/diagnóstico por imagem , Carga de Trabalho
8.
Prosthet Orthot Int ; 44(6): 384-401, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33164655

RESUMO

The human-prosthesis interface is one of the most complicated challenges facing the field of prosthetics, despite substantive investments in research and development by researchers and clinicians around the world. The journal of the International Society for Prosthetics and Orthotics, Prosthetics and Orthotics International, has contributed substantively to the growing body of knowledge on this topic. In celebrating the 50th anniversary of the International Society for Prosthetics and Orthotics, this narrative review aims to explore how human-prosthesis interfaces have changed over the last five decades; how research has contributed to an understanding of interface mechanics; how clinical practice has been informed as a result; and what might be potential future directions. Studies reporting on comparison, design, manufacturing and evaluation of lower limb prosthetic sockets, and osseointegration were considered. This review demonstrates that, over the last 50 years, clinical research has improved our understanding of socket designs and their effects; however, high-quality research is still needed. In particular, there have been advances in the development of volume and thermal control mechanisms with a few designs having the potential for clinical application. Similarly, advances in sensing technology, soft tissue quantification techniques, computing technology, and additive manufacturing are moving towards enabling automated, data-driven manufacturing of sockets. In people who are unable to use a prosthetic socket, osseointegration provides a functional solution not available 50 years ago. Furthermore, osseointegration has the potential to facilitate neuromuscular integration. Despite these advances, further improvement in mechanical features of implants, and infection control and prevention are needed.


Assuntos
Membros Artificiais/tendências , Desenho de Prótese/tendências , Ajuste de Prótese/tendências , Implantação de Prótese/tendências , Previsões , Humanos , Extremidade Inferior , Osseointegração
9.
Clin J Am Soc Nephrol ; 15(11): 1622-1630, 2020 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-32967922

RESUMO

BACKGROUND AND OBJECTIVES: Patients on dialysis are at high risk of complications related to implantable cardioverter defibrillator (ICD) implantation; use of subcutaneous ICDs may be preferred over transvenous devices due to lower risk of bloodstream infection and interference with vascular access sites. We evaluated trends in use and in-hospital outcomes of subcutaneous compared with transvenous ICDs among patients on dialysis in the United States. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Retrospective analysis of ICD implants from 2012 to 2018 among patients on dialysis reported to the National Cardiovascular Data Registry ICD Registry, a nationally representative US ICD Registry. We examined overall trends in subcutaneous ICD adoption as a proportion of all eligible ICD implants among patients on dialysis and then compared in-hospital outcomes between eligible subcutaneous ICD and transvenous ICD recipients using inverse probability of treatment weighting. RESULTS: Of the 23,136 total ICD implants in patients on dialysis during the study period, 3195 (14%) were subcutaneous ICDs. Among eligible first-time ICD recipients on dialysis, the proportion of subcutaneous ICDs used increased yearly from 10% in 2012 to 69% in 2018. In propensity score-weighted analysis of 3327 patients, compared with transvenous ICDs, patients on dialysis receiving subcutaneous ICDs had a higher rate of in-hospital cardiac arrest (2% versus 0.4%, P=0.002), but there was no significant difference in total in-hospital complications (2% versus 1%, P=0.08), all-cause death, or length of hospital stay. CONCLUSIONS: The utilization of subcutaneous ICDs among US patients on dialysis has been steadily increasing. The overall risk of short-term complications is low and comparable with transvenous ICDs, but higher risks of in-hospital cardiac arrest merits closer monitoring and further investigation. PODCAST: This article contains a podcast at https://www.asn-online.org/media/podcast/CJASN/2020_09_23_CJN07920520.mp3.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Implantação de Prótese/métodos , Implantação de Prótese/tendências , Diálise Renal/estatística & dados numéricos , Desfibriladores Implantáveis/efeitos adversos , Feminino , Parada Cardíaca/epidemiologia , Mortalidade Hospitalar , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/efeitos adversos , Sistema de Registros , Diálise Renal/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo , Estados Unidos/epidemiologia
10.
Spine (Phila Pa 1976) ; 45(15): 1024-1029, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32675601

RESUMO

STUDY DESIGN: Retrospective analysis using data from RCTs. OBJECTIVE: This study aimed to report on the incidence of radiological adjacent segment degeneration (ASD) in patients with cervical radiculopathy due to a herniated disc that were randomized to receive cervical arthroplasty or arthrodesis. SUMMARY OF BACKGROUND DATA: Cervical disc prostheses were introduced to prevent ASD in the postsurgical follow-up. However, it is still a controversial issue. METHODS: Two hundred fifty-three patients were included in two randomized, double-blinded trials comparing anterior cervical discectomy with arthroplasty (ACDA), with intervertebral cage (ACDF), or without intervertebral cage (ACD) for one-level disc herniation. Neutral lateral radiographs were obtained preoperatively, at 1- and 2-year follow-up after surgery. Radiological ASD was evaluated on X-ray and defined by a decrease in disc height and the presence of anterior osteophyte formation on both the superior and the inferior level in relation to the target level. RESULTS: Radiological ASD was present in 34% of patients at baseline and increased to 59% at 2-year follow-up in the arthrodesis groups (ACD and ACDF combined), and to 56% in the arthroplasty group. Progression of radiological ASD was present in 29% of patients in the arthrodesis group and in 31% of patients in the arthroplasty group for 2-year follow-up. CONCLUSIONS: Radiological ASD occurs in a similar manner in patients who were subjected to arthrodesis in cervical radiculopathy and in patients who received arthroplasty to maintain motion. Current data tend to indicate that the advantage of cervical prosthesis in preventing radiological ASD is absent. LEVEL OF EVIDENCE: 2.


Assuntos
Artroplastia/tendências , Vértebras Cervicais/cirurgia , Discotomia/tendências , Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral/cirurgia , Implantação de Prótese/tendências , Adulto , Artroplastia/efeitos adversos , Vértebras Cervicais/diagnóstico por imagem , Discotomia/efeitos adversos , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/prevenção & controle , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos
11.
Spine (Phila Pa 1976) ; 45(19): 1329-1334, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32576776

RESUMO

STUDY DESIGN: Retrospective analysis using data from randomized clinical trials. OBJECTIVE: To compare the occurrence of heterotopic ossification (HO) between two cervical disc prostheses. Clinical outcome and range of motion (ROM) were also evaluated. SUMMARY OF BACKGROUND DATA: Cervical arthroplasty was reported to be able to maintain the segmental ROM. However, controversy exists since the difference of the occurrence of HO concerning cervical prosthesis is still huge. METHODS: Patients who underwent anterior cervical discectomy with arthroplasty for a cervical radiculopathy due to a herniated disc from the The Netherlands Cervical Kinematics (NECK) trial (activC; metal endplates with a polyethylene inlay and a keel for primary stability) and the PROCON trial (Bryan; metal-on-polymer with titanium coated endplates without a keel) were analyzed for HO at 12 and 24 months postoperatively. HO was scored according to the McAfee-Mehren classification. Segmental ROM was defined by a custom developed image analysis tool, and global cervical ROM was measured by Cobb's angle. Clinical outcome was evaluated by means of the neck disability index (NDI) as well as physical-component summary (PCS) and mental-component summary (MCS). RESULTS: At 2-year follow-up, the occurrence of HO was 68% in patients treated with the activC prosthesis (severe HO 55%), which was comparable with 85% (P = 0.12) in patients with the Bryan disc (severe HO 44%; P = 0.43). The HO progression was similar between groups. Clinically, the patients had comparable NDI, PCS, and MCS at 2-year follow-up, and comparable improvement of clinical outcomes. The global ROM in the Bryan group (56.4 ±â€Š10.8°) was significantly higher than in the activC group (49.5 ±â€Š14.0, P = 0.044) at 2-year follow-up. CONCLUSION: In comparison of two cervical disc prostheses the development of HO is independent on their architecture. Although global ROM was higher in the Bryan prosthesis group, this difference was not deemed clinically important, particularly because the clinical condition of patients with and without severe HO was comparable. LEVEL OF EVIDENCE: 2.


Assuntos
Artroplastia/tendências , Prótese Ancorada no Osso/tendências , Vértebras Cervicais/diagnóstico por imagem , Discotomia/tendências , Ossificação Heterotópica/diagnóstico por imagem , Implantação de Prótese/tendências , Adulto , Artroplastia/efeitos adversos , Prótese Ancorada no Osso/efeitos adversos , Vértebras Cervicais/cirurgia , Discotomia/instrumentação , Método Duplo-Cego , Feminino , Humanos , Degeneração do Disco Intervertebral/diagnóstico por imagem , Degeneração do Disco Intervertebral/epidemiologia , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/epidemiologia , Deslocamento do Disco Intervertebral/cirurgia , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Ossificação Heterotópica/epidemiologia , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
12.
Circ Heart Fail ; 13(4): e006544, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32233662

RESUMO

BACKGROUND: The Affordable Care Act (ACA) has been associated with increased heart transplant listings among blacks, who are disproportionately uninsured. It is unclear whether the ACA is also associated with increased ventricular assist device implantation in blacks. METHODS: Using Healthcare Cost and Utilization Project Data State Inpatient Databases from 19 states and Washington DC, we analyzed 1157 patients from early-adopter states (ACA Medicaid expansion by January 2014) and 785 patients from nonadopter states (no implementation from 2013 to 2014). Piecewise Poisson regression with a discontinuity was used to estimate change in census-adjusted rates of ventricular assist device implants by race and ACA adopter status 1 year before and after January 2014. RESULTS: Following the ACA Medicaid expansion, the proportional change in rate increased significantly among blacks from early adopter (1.40 [95% CI, 1.12-1.75], pre 0.57/100 000 to post-ACA 0.80/100 000) but not nonadopter states (1.25 [95% CI, 0.98-1.58], pre 0.40/100 000 to post-ACA 0.50/100 000). However, the early and nonadopter changes in implantation rates were not statistically different from each other (P=0.50). There were no immediate changes in whites in either state group following the ACA Medicaid expansion (early adopter, 1.12 [95% CI, 0.98-1.29], pre 0.27/100 000 to post-ACA 0.30/100 000; nonadopter, 0.98 [95% CI, 0.82-1.16], pre 0.27/100 000 to post-ACA 0.26/100 000). CONCLUSIONS: Among eligible states participating in Healthcare Cost and Utilization Project Data State Inpatient Databases, the ACA was not associated with immediate changes in ventricular assist device implantation rates by race. Although a significant increase in implantation rate was observed among blacks from early-adopter states, the change was not statistically different from the change seen in nonadopter states.


Assuntos
Negro ou Afro-Americano , Disparidades em Assistência à Saúde/tendências , Insuficiência Cardíaca/terapia , Coração Auxiliar/tendências , Medicaid/tendências , Avaliação de Processos e Resultados em Cuidados de Saúde/tendências , Patient Protection and Affordable Care Act/tendências , Implantação de Prótese/tendências , População Branca , Adulto , Idoso , Bases de Dados Factuais , Definição da Elegibilidade/tendências , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Prática Médica/tendências , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Função Ventricular , Adulto Jovem
13.
Open Heart ; 7(1): e001214, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32201591

RESUMO

Objectives: To describe the contemporary trends in the use of mechanical circulatory support (MCS) in patients with acute myocardial infarction and cardiogenic shock (AMICS). To evaluate survival benefit with early application of intra-aortic balloon pump (IABP) or Impella CP. Methods: A cohort study of all consecutive patients with AMICS undergoing percutaneous coronary intervention (PCI) <24 hours of symptom onset (early PCI) in southeastern Denmark from 2010 to 2017. A matched case-control study comparing 30-day mortality between patients receiving early-IABP or early-Impella CP and their respective control group. Controls were matched on age, left ventricular ejection fraction, arterial lactate, estimated glomerular filtration rate and cardiac arrest before PCI. Early-IABP/Impella CP was defined as applied before PCI if shock developed pre-PCI, or immediately after PCI if shock developed during PCI. Results: 903 patients with AMICS undergoing early PCI were identified. Use of MCS decreased from 50% in 2010 to 25% in 2017, p for trend of <0.001. The IABP was abandoned in 2012 and replaced mostly by Impella CP. Patients receiving MCS in 2013-2017 had more compromised haemodynamics compared with patients receiving MCS in 2010-2012. 40 patients received early IABP, and 40 patients received early Impella CP. Only the group receiving early Impella CP was associated with lower 30-day mortality compared with their matched control group (30-day mortality 40% vs 77.5%, plog-rank of<0.001). Conclusion: Use of MCS decreased by 50% from 2010 to 2017. Patients receiving MCS had more compromised haemodynamics in recent years. Early application of Impella CP was associated with reduced 30-day mortality compared with a matched control group.


Assuntos
Coração Auxiliar/tendências , Balão Intra-Aórtico/tendências , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/tendências , Padrões de Prática Médica/tendências , Implantação de Prótese/tendências , Choque Cardiogênico/terapia , Idoso , Difusão de Inovações , Feminino , Humanos , Balão Intra-Aórtico/efeitos adversos , Balão Intra-Aórtico/mortalidade , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese/tendências , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/mortalidade , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
14.
Trends Cardiovasc Med ; 30(4): 223-229, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31201005

RESUMO

Early generation left ventricular assist devices (LVAD) for treatment of refractory heart failure attempted to mimic the pulsatility of a native heart and were bulky and less durable due to valves within the inflow and outflow pathways. The next disruption came with the introduction of continuous flow pumps characterized by a low-pulse pressure circulation. Since the mechanism of action did not involve displacement of blood, these pumps were much smaller and less noisy in part due to fewer moving parts. Such devices include the HeartMate II axial-flow pathway pump which is implanted thoraco-abdominally and the HVAD, a centrifugal-flow pathway pump which is smaller and is implanted entirely within the thoracic cavity and uses a combination of hydrodynamic and magnetic levitation of the internal rotor. These pumps improved survival compared with the early generation LVADs and in a trial, the HVAD demonstrated non-inferiority compared with the HeartMate II but with an increase in ischemic and hemorrhagic strokes. The HeartMate 3 LVAD is an intrapericardial centrifugal-flow pathway pump with a full magnetically levitated, frictionless rotor with a fixed intrinsic pulse. In a randomized trial, the HeartMate 3 "hybrid" pump was associated with near-elimination of pump thrombosis, a reduction in strokes of any type or severity and lower mucosal bleeding rates. Despite improvements in hemocompatibility, right heart failure and infections contribute to significant morbidity, and devices designed to be internally contained with a wireless power source and physiological flow characteristics are still required despite great strides in the field.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/tendências , Magnetismo/tendências , Implantação de Prótese/tendências , Função Ventricular Esquerda , Animais , Difusão de Inovações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Desenho de Prótese/tendências , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento
15.
Asian J Androl ; 22(1): 70-75, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31571642

RESUMO

Since their popularization, genitourinary prosthetics have remained a gold-standard therapy for the treatment of erectile dysfunction and stress urinary incontinence and in cases of testicular loss or dysfunction. They have also represented an area of significant innovation, which has contributed to excellent long-term outcomes. Given this history, the objective of the current review was to provide a 5-10-year outlook on anticipated trends and developments in the field of genitourinary prosthetics. To accomplish this objective, a PubMed and patent search was performed of topics relating to penile and testicular prostheses and urinary sphincters. In regard to penile prostheses, findings demonstrated several new concepts including temperature-sensitive alloys, automated pumps, devices designed specifically for neophalluses, and improved malleable designs. With artificial urinary sphincters, new concepts include the ability to add or remove fluid from an existing system, two-piece systems, and new mechanisms to occlude the urethra. For testicular prosthetics, future implementations may not only better replicate the feel of a biological testicle but also add endocrinological functions. Beyond device innovation, the future of prosthetics is also one of expanding geographic boundaries, which necessitates variable cost modeling and regulatory considerations. Surgical trends are also changing, with a greater emphasis on nonnarcotic, postoperative pain control, outpatient surgeries, and adjunctive techniques to lengthen the penis and address concomitant stress incontinence, among others. Concomitant with device and surgical changes, future considerations also include a greater need for education and training, particularly given the rapid expansion of sexual medicine into developing nations.


Assuntos
Prótese de Pênis/tendências , Desenho de Prótese/tendências , Implantação de Prótese/tendências , Esfíncter Urinário Artificial/tendências , Procedimentos Cirúrgicos Urológicos Masculinos/tendências , Disfunção Erétil/cirurgia , Humanos , Masculino , Implante Peniano , Prótese de Pênis/economia , Próteses e Implantes/economia , Próteses e Implantes/tendências , Doenças Testiculares/cirurgia , Incontinência Urinária por Estresse/cirurgia , Esfíncter Urinário Artificial/economia
16.
J Orthop Surg Res ; 14(1): 350, 2019 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-31703710

RESUMO

BACKGROUND: The incidence of intertrochanteric hip fracture is expected to increase as the global population ages. It is one of the most important causes of mortality and morbidities in the geriatric population. The incidence of reverse oblique and transverse intertrochanteric (AO/OTA 31-A3) fractures is relatively low; however, the incidence of implant failure in AO/OTA 31-A3 fractures is relatively high compared with that in AO/OTA 31-A1 and A2 fractures. To date, the risk factors for implant failure in AO/OTA 31-A3 fractures treated with proximal femoral nail antirotation (PFNA) have remained ambiguous. The purpose of this study was to identify the predictive factors of implant failure in AO/OTA 31-A3 fractures treated with PFNA. METHODS: The data of all patients who underwent surgery for trochanteric fractures at our institution between January 2006 and February 2018 were retrospectively reviewed. All AO/OTA 31-A3 fractures treated with PFNA were included. Logistic regression analysis of potential predictors of implant failure was performed. Potential predictors included age, sex, body mass index, fracture type, reduction method, status of posteromedial support and lateral femoral wall, reduction quality, tip-apex distance and position of the helical blade in the femoral head. RESULTS: One hundred four (9.3%) patients with AO/OTA 31-A3 fractures were identified. Forty-five patients with AO/OTA 31-A3 fractures treated with PFNA were suitable for our study. Overall, implant failure occurred in six (13.3%) of forty-five patients. Multivariate analysis identified poor reduction quality (OR, 28.70; 95% CI, 1.91-431.88; p = 0.015) and loss of posteromedial support (OR, 18.98; 95% CI, 1.40-257.08; p = 0.027) as factors associated with implant failure. CONCLUSIONS: Poor reduction quality and loss of posteromedial support are predictors of implant failure in reverse oblique and transverse intertrochanteric fractures treated with PFNA.


Assuntos
Pinos Ortopédicos/efeitos adversos , Fêmur/cirurgia , Fraturas do Quadril/cirurgia , Falha de Prótese/efeitos adversos , Implantação de Prótese/efeitos adversos , Rotação , Adulto , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos/tendências , Feminino , Fêmur/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese/tendências , Implantação de Prótese/tendências , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
17.
J Orthop Surg Res ; 14(1): 346, 2019 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-31699134

RESUMO

BACKGROUND: Osteosarcoma is the most common primary malignant bone tumor in adults and is usually located in the long bones. Standard treatment consists of perioperative chemotherapy and radical surgical resection. Limb-sparing surgery using a variety of reconstructive techniques remains the gold standard. METHODS: In our study, we retrospectively analyzed 90 adult patients operated at our institution between 2000 and 2017 for extremity osteosarcoma that underwent limb-sparing reconstruction with the megaprosthesis. Sixty-one patients underwent resection and reconstruction of the distal femur, 9 patients-proximal femur, 7 patients-proximal tibia, 5 patients-total femoral resection and reconstruction, 5 patients-proximal humeral resection, and 3 patients-other types of resection with endoprosthetic reconstruction. The median follow-up time was 41 months, median overall survival was 86 months (3-225 months), and progression-free survival was 81 months (1-86 months). Functional assessment was made on 48 out of 56 living patients, after endoprosthetic reconstruction. The assessment was made according to MSTS functional scale. RESULTS: In 14 cases (15%), the endoprosthesis had to be explanted, or amputation was performed for local recurrence or septic complication. Due to a mechanical failure of the implant, we had to perform a revision in 5 patients (5%). Eighteen out of 74 patients with endoprosthesis died of the disease. The median MSTS score was 84% (53-100%), and the best result of 85% was achieved in patients after distal femoral resection with endoprosthetic reconstruction. CONCLUSION: Careful planning of the treatment of patients with extremity osteosarcoma that is performed at the referral centers gives the possibility of long-term survival with a good and excellent functional result.


Assuntos
Neoplasias Ósseas/cirurgia , Salvamento de Membro/tendências , Osteossarcoma/cirurgia , Procedimentos de Cirurgia Plástica/tendências , Implantação de Prótese/tendências , Recuperação de Função Fisiológica/fisiologia , Adulto , Idoso , Neoplasias Ósseas/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Salvamento de Membro/métodos , Masculino , Pessoa de Meia-Idade , Osteossarcoma/diagnóstico por imagem , Implantação de Prótese/métodos , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
JAMA Netw Open ; 2(10): e1913553, 2019 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-31626314

RESUMO

Importance: Defibrillation testing (DFT) is performed during implantable cardioverter-defibrillator (ICD) implantation to assess the capacity of the device to detect and terminate ventricular arrhythmias. However, DFT can result in complications and omission of its use has been shown to be safe. Objective: To describe temporal trends and variation in the use of DFT in contemporary practice in the United States. Design, Setting, and Participants: This multicenter cross-sectional study used data from the National Cardiovascular Data Registry ICD Registry. A total of 499 211 patients from 1794 different facilities undergoing first-time ICD implantation from April 2010 to December 2015 were included. Data analysis was performed from May 20, 2015, to August 15, 2019. Exposure: Defibrillation testing was assessed using the National Cardiovascular Data Registry ICD Registry. Main Outcomes and Measures: Defibrillation testing rates and median odds ratios (MORs) were assessed over time. The MOR represents the odds that a randomly selected patient receiving testing at a hospital with high testing rates would be tested compared with if he or she had received care at a hospital with low testing rates. Results: Of the 499 211 patients from 1794 different facilities included in this analysis, the mean (SD) age of the population was 65.5 (13.4) years and 356 681 patients (71.4%) were men. The use of DFT declined from 71.6% in the first calendar quarter of 2010 to 36.4% in the fourth quarter of 2015 (P < .001). Patients undergoing DFT were more likely than those without testing to have ischemic heart disease (170 569 [58.1%] vs 116 295 [56.6%]), ventricular tachycardia (91 500 [31.2%] vs 58 949 [28.7%]), and less advanced heart failure (New York Heart Association class I and II, 153 188 [52.2%] vs 91 215 [44.4%]) (P < .001 for all). The MOR for the use of defibrillation testing was 3.78 (95% CI, 3.54-4.03) in 2010, increasing to 6.05 (95% CI, 5.61-6.52) in 2015, indicating that by 2015 a randomly selected patient receiving testing at a hospital with high testing rates would have a 6-fold higher odds of being tested than if they had received care at a hospital with low testing rates. Conclusions and Relevance: Defibrillation testing at the time of ICD placement in the United States may have declined over time; however, institutional variation in its use appears to be marked and increased. This variability in the reduced use of defibrillation testing could reflect differences in individual or institutional cultures of practice.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Hospitais/estatística & dados numéricos , Implantação de Prótese/estatística & dados numéricos , Idoso , Estudos Transversais , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Implantação de Prótese/métodos , Implantação de Prótese/tendências , Sistema de Registros , Taquicardia Ventricular/terapia , Fatores de Tempo
19.
Circ Heart Fail ; 12(9): e006082, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31514517

RESUMO

BACKGROUND: Women comprise approximately one-third of the advanced heart failure population but may receive fewer advanced heart failure therapies including left ventricular assist devices (LVADs). During the early pulsatile-flow device era, women had higher post-LVAD mortality and increased complications. However, knowledge about these differences in the continuous-flow device era is limited. Therefore, we sought to explore temporal trends in LVAD utilization and post-LVAD mortality by sex. METHODS AND RESULTS: Patients with LVAD implantation from 2004 to 2016 were identified using the Nationwide Inpatient Sample. Trends in LVAD utilization and post-LVAD inpatient mortality were compared by sex and device era. Although LVADs are being increasingly utilized for patients with advanced systolic heart failure, women continue to represent a smaller proportion of LVAD recipients-25.8% in 2004 to 21.9% in 2016 (P for trend, 0.91). Women had increased inpatient mortality after LVAD implantation compared with men in the pulsatile-flow era (46.9% versus 31.1%, P<0.0001) but not in the continuous-flow era (13.3% versus 12.1%, P=0.27; P for interaction=0.0002). Inpatient mortality decreased for both sexes over time after LVAD, with a sharp fall in 2008 to 2009. Female sex was independently associated with increased post-LVAD inpatient mortality beyond adjustment for demographics and risk factors during the pulsatile-flow era (odds ratio, 2.13; 95% CI, 1.45-3.10; P<0.0001) but not during the continuous-flow era (1.18; 0.93-1.48; P=0.16). CONCLUSIONS: Although utilization of LVAD therapy increased over time for both sexes, LVAD implantation remains stably lower in women, which may suggest a potential underutilization of this potentially life-saving therapy. Prospective studies are needed to confirm these findings.


Assuntos
Mau Uso de Serviços de Saúde/tendências , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/tendências , Mortalidade Hospitalar/tendências , Implantação de Prótese/estatística & dados numéricos , Adulto , Idoso , Bases de Dados Factuais , Feminino , Mau Uso de Serviços de Saúde/estatística & dados numéricos , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/mortalidade , Implantação de Prótese/tendências , Fatores Sexuais , Estados Unidos/epidemiologia
20.
World Neurosurg ; 130: e251-e258, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31207376

RESUMO

OBJECTIVE: To investigate the characteristics of materials used as prostheses for microvascular decompression surgery (MVDs) in Japan and their possible adverse events (AEs) to determine preferable materials for MVDs. METHODS: A questionnaire was sent to all members of the Japanese Society for MVDs, and answers were obtained from 59 institutions. RESULTS: Among a total of 2789 MVDs, 1088 operations for trigeminal neuralgia, 1670 for hemifacial spasm, and 31 others, including 117 reoperations, were performed between April 2011 and March 2014. Nonabsorbable material was used in 96.5% of MVDs, including polytetrafluoroethylene (PTFE) (80.5%), polyurethane (11.9%), expanded PTFE (2.1%), and silk thread (1.47%). The use of absorbable materials, including fibrin glue (87.5%), cellulose (13.5%), gelatin (4,77%), and collagen (1.76%), was reported. The major combinations were PTFE with fibrin glue (58.7%) followed by PTFE alone (7.60%). Eighty-eight AEs in 85 (3.2%) cases were reported among 2672 first operations. AEs included 51 central nervous system dysfunctions, 15 wound infections/dehiscence, and 10 others, which were presumed to be related to the intraoperative procedure. Among relatively high-, moderate-, and low-volume centers, there were no significant differences in the frequency of AEs (P = 0.077). Tissue-prosthesis adhesion and/or granuloma formation were reported in 13 cases of 117 reoperations. The incidence of adhesion-related recurrence was 11.1% of all reoperations. CONCLUSIONS: The number of AEs was quite low in this survey, and intradural use of any prosthesis reported in this paper might be justified; however, further development of easily handled and less-adhesive prosthesis materials is awaited.


Assuntos
Prótese Vascular , Cirurgia de Descompressão Microvascular/instrumentação , Implantação de Prótese/instrumentação , Sociedades Médicas , Inquéritos e Questionários , Prótese Vascular/tendências , Humanos , Japão , Cirurgia de Descompressão Microvascular/tendências , Implantação de Prótese/tendências , Sociedades Médicas/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA