Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 543
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
2.
Heart Vessels ; 39(6): 556-562, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38368576

RESUMO

Cardiac magnetic resonance imaging (CMR) often shows discrepancies between right ventricular outflow tract (RVOT) flow and left ventricular outflow tract flow in patients with late-stage repaired tetralogy of Fallot (rTOF), leading to potential errors in pulmonary regurgitation fraction (PRF) assessment. This study aimed to identify the conditions under which RVOT flow can be acutely evaluated using four-dimensional (4D) flow CMR. Twenty-seven consecutive patients with rTOF underwent both two-dimensional phase-contrast (2D PC) and 4D flow CMR between 2016 and 2018, excluding those with peripheral pulmonary artery stenosis, RVOT conduit replacement, unknown surgical method, and an aortic valve regurgitation greater than 20%. Seven healthy controls also underwent only 4D Flow CMR. All healthy controls and fifteen patients with rTOF showed laminar RVOT flow, while seven patients exhibited helical, and four patients exhibited vortical RVOT flow in 4D flow CMR visualization. Flow-volume concordance between the pulmonary artery and aortic flow was significantly lower in patients with rTOF and PRF > 40% in 2D PC CMR. This concordance rate in the suprapulmonary valve was high in both the TOF and control groups, comparing at five RVOT locations in 4D flow CMR. Regarding RVOT flow regurgitation in 4D flow, the whole bulk evaluation exhibited greater variation depending on the flow type compared to the whole pixel-wise evaluation. The study confirmed the flow volume at the upper section of the pulmonary valve as the most accurate correlate of aortic flow volume. Furthermore, the 4D flow CMR using the pixel-wise method demonstrated superior accuracy compared to the traditional bulk flow method.


Assuntos
Imagem Cinética por Ressonância Magnética , Tetralogia de Fallot , Humanos , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Masculino , Feminino , Adulto , Imagem Cinética por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Adolescente , Procedimentos Cirúrgicos Cardíacos/métodos , Adulto Jovem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Estudos Retrospectivos , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Criança , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
3.
J Thorac Cardiovasc Surg ; 163(4): e299-e308, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34446290

RESUMO

BACKGROUND: Ventricular interdependence may account for altered ventricular mechanics in congenital heart disease. The present study aimed to identify differences in load-dependent right ventricular (RV)-left ventricular (LV) interactions in porcine models of pulmonary stenosis (PS) and pulmonary insufficiency (PI) by invasive admittance-derived hemodynamics in conjunction with noninvasive cardiovascular magnetic resonance (CMR). METHODS: Seventeen pigs were used in the study (7 with PS, 7 with PI, and 3 controls). Progressive PS was created by tightening a Teflon tape around the pulmonary artery, and PI was created by excising 2 leaflets of the pulmonary valve. Admittance catheterization data were obtained for the RV and LV at 10 to 12 weeks after model creation, with the animal ventilated under temporary diaphragm paralysis. CMR was performed in all animals immediately prior to pressure-volume catheterization. RESULTS: In the PS group, RV contractility was increased, manifested by increased end-systolic elastance (mean difference, 1.29 mm Hg/mL; 95% confidence interval [CI], 0.57-2.00 mm Hg/mL). However, in the PI group, no significant changes were observed in RV systolic function despite significant changes in RV diastolic function. In the PS group, LV end-systolic volume was significantly lower compared with controls (mean difference, 25.1 mL; 95% CI, -40.5 to -90.7 mL), whereas in the PI group, the LV showed diastolic dysfunction, demonstrated by an elevated isovolumic relaxation constant and ventricular stiffness (mean difference, 0.03 mL-1; 95% CI, -0.02 to 0.09 mL-1). CONCLUSIONS: The LV exhibits systolic dysfunction and noncompliance with PI. PS is associated with preserved LV systolic function and evidence of some LV diastolic dysfunction. Interventricular interactions influence LV filling and likely account for differential effects of RV pressure and volume overload on LV function.


Assuntos
Diástole/fisiologia , Disfunção Ventricular/fisiopatologia , Pressão Ventricular/fisiologia , Animais , Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Modelos Animais , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Volume Sistólico/fisiologia , Suínos , Sístole/fisiologia , Disfunção Ventricular/diagnóstico por imagem
4.
Sci Rep ; 11(1): 18879, 2021 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-34556756

RESUMO

We measured right ventricular (RV) strain by applying a novel postprocessing technique to conventional short-axis cine magnetic resonance imaging in the repaired tetralogy of Fallot (TOF) and investigated whether pulmonary valve replacement (PVR) changes the RV strain. Twenty-four patients with repaired TOF who underwent PVR and 16 healthy controls were enrolled. Global maximum and minimum principal strains (GPSmax, GPSmin) and global circumferential and longitudinal strains (GCS, GLS) were measured from short-axis cine images reconstructed radially along the long axis. Strain parameters before and after PVR were compared using paired t-tests. One-way ANOVA with Tukey post-hoc analysis was used for comparisons between the before and after PVR groups and the control group. There were no differences in strain parameters before and after PVR. The GPSmax before PVR was lower than that in the control group (P = 0.002). Before and after PVR, GCSs were higher and GLSs were lower than those in the control group (before and after GCSs: P = 0.002 for both, before and after GLSs: P < 0.0001 and P = 0.0003). RV strains from radially reconstructed short-axis cine images revealed unchanged myocardial motion after PVR. When compared to the control group, changes in GCS and GLS in TOF patients before and after PVR might be due to RV remodeling.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Função Ventricular Direita/fisiologia , Remodelação Ventricular/fisiologia , Adulto Jovem
5.
Sci Rep ; 11(1): 11623, 2021 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-34079023

RESUMO

We used 4D-flow MRI to investigate circulation, an area integral of vorticity, in the main pulmonary artery (MPA) as a new hemodynamic parameter for assessing patients with a repaired Tetralogy of Fallot (TOF). We evaluated the relationship between circulation, right ventricular (RV) function and the pulmonary regurgitant fraction (PRF). Twenty patients with a repaired TOF underwent cardiac MRI. Flow-sensitive 3D-gradient sequences were used to obtain 4D-flow images. Vortex formation in the MPA was visualized, with short-axis and longitudinal vorticities calculated by software specialized for 4D flow. The RV indexed end-diastolic/end-systolic volumes (RVEDVi/RVESVi) and RV ejection fraction (RVEF) were measured by cine MRI. The PR fraction (PRF) and MPA area were measured by 2D phase-contrast MRI. Spearman ρ values were determined to assess the relationships between circulation, RV function, and PRF. Vortex formation in the MPA occurred in 15 of 20 patients (75%). The longitudinal circulation (11.7 ± 5.1 m2/s) was correlated with the RVEF (ρ = - 0.85, p = 0.0002), RVEDVi (ρ = 0.62, p = 0.03), and RVESVi (ρ = 0.76, p = 0.003) after adjusting for the MPA size. The short-axis circulation (9.4 ± 3.4 m2/s) in the proximal MPA was positively correlated with the MPA area (ρ = 0.61, p = 0.004). The relationships between the PRF and circulation or RV function were not significant. Increased longitudinal circulation in the MPA, as demonstrated by circulation analysis using 4D flow MRI, was related to RV dysfunction in patients with a repaired TOF.


Assuntos
Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Criança , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Volume Sistólico/fisiologia , Tetralogia de Fallot/patologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia
6.
Am J Physiol Heart Circ Physiol ; 321(1): H38-H51, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-34048283

RESUMO

Pulmonary regurgitation (PR) after repair of tetralogy of Fallot (rTOF) is associated with progressive right (RV) and left (LV) ventricular dysfunction and fibrosis. However, angiotensin II receptor blockade therapy has shown mixed and often disappointing results. The aim of this study was to serially assess changes in biventricular remodeling, dysfunction, and interactions in a rat model of isolated severe PR and to study the effects of angiotensin II receptor blockade. PR was induced in Sprague-Dawley rats by leaflet laceration. Shams (n = 6) were compared with PR (n = 5) and PR + losartan treatment (n = 6). In the treatment group, oral losartan (50 mg·kg-1·day-1) was started 6 wk after PR induction and continued for 6 wk until the terminal experiment. In all groups, serial echocardiography was performed every 2 wk until the terminal experiment where biventricular myocardium was harvested and analyzed for fibrosis. PR and PR + losartan rats experienced early progressive RV dilatation by 2 wk which then stabilized. RV systolic dysfunction occurred from 4 wk after insult and gradually progressed. In PR rats, RV dilatation caused diastolic LV compression and impaired relaxation. PR rats developed increased RV fibrosis compared with shams. Although losartan decreased RV fibrosis, RV dilatation and dysfunction were not improved. This suggests that RV dilatation is an early consequence of PR and affects LV relaxation. RV dysfunction may progress independent of further remodeling. Reduced RV fibrosis was not associated with improved RV function and may not be a viable therapeutic target in rTOF with predominant RV volume loading.NEW & NOTEWORTHY The time-course of RV dilatation and the mechanisms of biventricular dysfunction caused by PR have not been well characterized and the effect of losartan in volume-overloaded RV remains controversial. Our findings suggest that severe PR induces early onset of RV dilatation and dysfunction with little progression after the first 4 wk. The RV dilatation distorts LV geometry with associated impaired LV relaxation. Losartan reduced RV fibrosis but did not reverse RV dilatation and dysfunction.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Losartan/uso terapêutico , Insuficiência da Valva Pulmonar/complicações , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Direita/tratamento farmacológico , Animais , Modelos Animais de Doenças , Ecocardiografia , Fibrose/tratamento farmacológico , Fibrose/etiologia , Fibrose/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Ratos , Ratos Sprague-Dawley , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia
7.
Ultrasound Med Biol ; 47(6): 1514-1527, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33685744

RESUMO

Using blood speckle tracking (BST) based on high-frame-rate echocardiography (HFRE), we compared right ventricle (RV) flow dynamics in children with atrial septal defects (ASDs) and repaired tetralogy of Fallot (rTOF). Fifty-seven children with rTOF with severe pulmonary insufficiency (PI) (n = 21), large ASDs (n = 11) and healthy controls (CTL, n = 25) were included. Using a flow phantom, we studied the effects of imaging plane and smoothing parameters on 2-D energy loss (EL). RV diastolic EL was similar in ASD and rTOF, but both were greater than in CTL. Locations of high EL were similar in all groups in systole, occurring in the RV outflow tract and around the tricuspid valve leaflets in early diastole. An additional apical early diastolic area of EL was noted in rTOF, corresponding to colliding tricuspid inflow and PI. The flow phantom revealed that EL varied with imaging plane and smoothing settings but that the EL trend was preserved if kept consistent.


Assuntos
Ecocardiografia/métodos , Comunicação Interatrial/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Complicações Pós-Operatórias/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/cirurgia , Criança , Pré-Escolar , Dilatação Patológica , Feminino , Ventrículos do Coração/patologia , Humanos , Lactente , Masculino , Fenômenos Físicos , Projetos Piloto , Fluxo Sanguíneo Regional
8.
Int J Cardiovasc Imaging ; 37(4): 1289-1299, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33389362

RESUMO

Our aim was to assess the regional right ventricular (RV) shape changes in pressure and volume overload conditions and their relations with RV function and mechanics. The end-diastolic and end-systolic RV endocardial surfaces were analyzed with three-dimensional echocardiography (3DE) in 33 patients with RV volume overload (rToF), 31 patients with RV pressure overload (PH), and 60 controls. The mean curvature of the RV inflow (RVIT) and outflow (RVOT) tracts, RV apex and body (both divided into free wall (FW) and septum) were measured. Zero curvature defined a flat surface, whereas positive or negative curvature indicated convexity or concavity, respectively. The longitudinal and radial RV wall motions were also obtained. rToF and PH patients had flatter FW (body and apex) and RVIT, more convex interventricular septum (body and apex) and RVOT than controls. rToF demonstrated a less bulging interventricular septum at end-systole than PH patients, resulting in a more convex shape of the RVFW (r = - 0.701, p < 0.0001), and worse RV longitudinal contraction (r = - 0.397, p = 0.02). PH patients showed flatter RVFW apex at end-systole compared to rToF (p < 0.01). In both groups, a flatter RVFW apex was associated with worse radial RV contraction (r = 0.362 in rToF, r = 0.482 in PH at end-diastole, and r = 0.555 in rToF, r = 0.379 in PH at end-systole, respectively). In PH group, the impairment of radial contraction was also related to flatter RVIT (r = 0.407) and more convex RVOT (r = - 0.525) at end-systole (p < 0.05). In conclusion, different loading conditions are associated to specific RV curvature changes, that are related to longitudinal and radial RV dysfunction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Hipertensão Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Função Ventricular Direita , Pressão Ventricular , Remodelação Ventricular , Adolescente , Adulto , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos de Casos e Controles , Criança , Feminino , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
11.
J Thorac Cardiovasc Surg ; 162(1): 196-205, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33097218

RESUMO

OBJECTIVES: A wide variety of right ventricular outflow tract (RVOT) and pulmonary artery (PA) geometries has been reported in patients with repaired tetralogy of Fallot (rTOF). We aimed to investigate the associations between RVOT/PA geometries and outcome indicators in a large rTOF cohort receiving non-conduit repair. METHODS: Three-dimensional magnetic resonance angiographic images of 206 patients with rTOF who had a pulmonary regurgitation (PR) fraction ≥20% were reviewed. Patients' RVOT geometry was quantitatively classified into 4 distinct shapes (tubular, hourglass, pyramid, and inverted trapezoid). Bilateral PA size discrepancy was defined as the diameter of the smaller side being less than 70% of that of the bigger side. RESULTS: Based on lateral projection of the 3-dimensional images, patients with an inverted trapezoid-shaped RVOT had the smallest RV end-diastolic volume index (EDVi) (108.7 ± 24.3 mL/m2) and pulmonary valve annulus diameter, and shortest QRS duration, whereas those with a pyramid-shaped RVOT had the largest RV EDVi (161.0 ± 44.6 mL/m2) and pulmonary valve annulus diameter. Similar trends of differences were also observed if such classifications were based on the frontal projections. Multivariable analysis revealed that RVOT shapes, subvalvular diameter, PR fraction, QRS duration, and the presence of bilateral PA size discrepancy were independent determinants of RV EDVi. Furthermore, having bilateral PA size discrepancy (25.2%) was independently associated with lower peak oxygen consumption (P = .041). CONCLUSIONS: Distinct RVOT morphologies and branch PA size discrepancy are associated with variations in RV remodeling and exercise capacity in patients with rTOF. These findings may aid decision-making regarding reintervention for PR and branch PA size discrepancy.


Assuntos
Ventrículos do Coração , Artéria Pulmonar , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Tolerância ao Exercício/fisiologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/patologia , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia , Adulto Jovem
12.
Am J Cardiol ; 141: 106-112, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-33217351

RESUMO

Ebstein anomaly (EA) and tricuspid valve dysplasia (TVD) are rare congenital malformations associated with nearly 50% mortality when diagnosed in utero. The diseases often produce severe tricuspid regurgitation (TR) in the fetus and in some cases, pulmonary regurgitation (PR) and circular shunting ensue. Since the ductus arteriosus (DA) plays a critical role in the circular shunt and may be constricted by transplacental nonsteroidal anti-inflammatory drugs (NSAIDs), we sought to assess the effect of NSAIDs on fetuses with EA/TVD. We reviewed mothers of singleton fetuses with EA/TVD and PR, indicative of circular shunting, who were offered NSAIDs at multiple centers from 2010 to 2018. Initial dosing consisted of indomethacin, followed by ibuprofen in most cases. Twenty-one patients at 10 centers were offered therapy at a median gestational age (GA) of 30.0 weeks (range: 20.9 to 34.9). Most (15/21 = 71%) mothers received NSAIDs, and 12 of 15 (80%) achieved DA constriction after a median of 2.0 days (1.0 to 6.0). All fetuses with DA constriction had improved PR; 92% had improved Doppler patterns. Median GA at pregnancy outcome (live-birth or fetal demise) was 36.1 weeks (30.7 to 39.0) in fetuses with DA constriction versus 33 weeks (23.3 to 37.3) in fetuses who did not receive NSAIDs or achieve DA constriction (p = 0.040). Eleven of 12 patients (92%) with DA constriction survived to live-birth, whereas 4 of 9 patients (44%) who did not receive NSAIDs or achieve DA constriction survived (p = 0.046). In conclusion, our findings demonstrate the proof of concept that NSAIDs mitigate circular shunt physiology by DA constriction and improve PR among fetuses with severe EA/TVD. Although the early results are encouraging, further investigation is necessary to determine safety and efficacy.


Assuntos
Anti-Inflamatórios não Esteroides/uso terapêutico , Canal Arterial/fisiopatologia , Anomalia de Ebstein/tratamento farmacológico , Terapias Fetais/métodos , Idade Gestacional , Insuficiência da Valva Pulmonar/tratamento farmacológico , Insuficiência da Valva Tricúspide/tratamento farmacológico , Valva Tricúspide/anormalidades , Constrição , Canal Arterial/diagnóstico por imagem , Duração da Terapia , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/fisiopatologia , Ecocardiografia , Feminino , Coração Fetal , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/tratamento farmacológico , Cardiopatias Congênitas/fisiopatologia , Humanos , Ibuprofeno/uso terapêutico , Indometacina/uso terapêutico , Nascido Vivo , Troca Materno-Fetal , Mortalidade Perinatal , Gravidez , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Ultrassonografia Doppler , Ultrassonografia Pré-Natal
14.
Pediatr Cardiol ; 42(2): 379-388, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33156379

RESUMO

Today, strategy of repair remains controversial and rare analyses on annular integrity associated with outcomes in complete repair by RVOT incision were performed in a large TOF cohort in China. This is a retrospective cohort study involving patients with TOF who had undergone complete repair by RVOT incision between January 2012 and December 2017 in Fuwai hospital. The primary outcome was a composite of reintervention, significant pulmonary regurgitation (PR) and significant annular peak gradient (APG). Multivariate Cox proportional-hazards model analyses were used to assess the relationships between annular integrity and outcomes. In total, 1673 survival patients with the median age of 318 days were included, and 1002 were male. During a median follow-up of 49 months, 538 participants developed the primary outcome (27 reinterventions). Multivariate Cox analyses showed that compared with AS, TAP was associated with an increased risk of primary outcome (adjusted HR, 1.94 [95% CI 1.60-2.37]) and the results remained unchanged even in most subgroups defined. In secondary outcomes analyses, TAP is associated with a higher risk of reintervention (adjusted HR, 3.32 [95% CI 1.25-8.79]) and significant PR (adjusted HR, 2.51 [95% CI 2.00-3.16]). However, TAP is not associated with a decreased risk of significant APG (adjusted HR, 1.33 [95% CI 0.94-1.88]). PVA integrity preservation is important in complete repair of TOF with RVOT incision. TAP is associated with a higher risk of reintervention and significant PR, and with a similar risk of significant APG. Significant APG in AS patients at discharge has a downtrend over time.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Insuficiência da Valva Pulmonar/fisiopatologia , Tetralogia de Fallot/cirurgia , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , China , Feminino , Humanos , Lactente , Masculino , Modelos de Riscos Proporcionais , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
15.
Heart ; 107(3): 223-228, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33199362

RESUMO

BACKGROUND AND OBJECTIVES: Chronic pulmonic regurgitation (PR) following repair of congenital heart disease (CHD) impairs right ventricular function that impacts peak exercise cardiac index (pCI). We aimed to estimate in a non-invasive way pCI and peak oxygen consumption (pVO2) and to evaluate predictors of low pCI in patients with significant residual pulmonic regurgitation after CHD repair. METHOD: We included 82 patients (median age 19 years (range 10-54 years)) with residual pulmonic regurgitation fraction >40%. All underwent cardiac MRI and cardiopulmonary testing with measurement of pCI by thoracic impedancemetry. Low pCI was defined <7 L/min/m2. RESULTS: Low pCI was found in 18/82 patients. Peak indexed stroke volume (pSVi) tended to compensate chronotropic insufficiency only in patients with normal pCI (r=-0.31, p=0.01). Below 20 years of age, only 5/45 patients had low pCI but near-normal (≥6.5 L/min/m2). pVO2 (mL/kg/min) was correlated with pCI (r=0.58, p=0.0002) only in patients aged >20 years. Left ventricular stroke volume in MRI correlated with pSVi only in the group of patients with low pCI (r=0.54, p=0.02). No MRI measurements predicted low pCI. In multivariable analysis, only age predicted a low pCI (OR=1.082, 95% CI 1.035 to 1.131, p=0.001) with continuous increase of risk with age. CONCLUSIONS: In patients with severe PR, pVO2 is a partial reflection of pCI. Risk of low pCI increases with age. No resting MRI measurement predicts low haemodynamic response to exercise. Probably more suitable to detect ventricular dysfunction, pCI measurement could be an additional parameter to take into account when considering pulmonic valve replacement.


Assuntos
Baixo Débito Cardíaco/metabolismo , Baixo Débito Cardíaco/fisiopatologia , Teste de Esforço , Consumo de Oxigênio , Insuficiência da Valva Pulmonar/metabolismo , Insuficiência da Valva Pulmonar/fisiopatologia , Adolescente , Adulto , Baixo Débito Cardíaco/etiologia , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/complicações , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
16.
J Cardiovasc Magn Reson ; 22(1): 68, 2020 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-32938483

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. METHODS: CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velocity offsets, net flow, clinically significant difference (deviation > 10% net flow), and regurgitation severity were assessed. RESULTS: Data from 175 patients (28 (17-38) years) were included, of which 84% had congenital heart disease. First, second and third order and optimized stationary tissue correction did not improve the velocity offsets and net flow measurements. Uncorrected measurements resulted in the least clinically significant differences in net flow compared to phantom corrected data. Optimized stationary tissue correction per scanner and software program resulted in net flow differences (> 10%) in 19% (MASS) and 30% (Circle cvi42) of all measurements compared to 18% (MASS) and 23% (Circle cvi42) with no correction. Compared to phantom correction, regurgitation reclassification was the least common using uncorrected data. One CMR scanner performed worse and significant net flow differences of > 10% were present both with and without stationary tissue correction in more than 30% of all measurements. CONCLUSION: Phase offset errors had a significant impact on net flow quantification, regurgitation assessment and varied greatly between CMR scanners. Background phase correction using stationary tissue correction worsened accuracy compared to no correction on three GE Healthcare CMR scanners. Therefore, careful assessment of phase offset errors at each individual scanner is essential to determine whether routine use of phantom correction is necessary. TRIAL REGISTRATION: Observational Study.


Assuntos
Aorta/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/instrumentação , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Aorta/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Criança , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Imagens de Fantasmas , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
18.
Semin Cardiothorac Vasc Anesth ; 24(4): 364-368, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32746732

RESUMO

Noonan syndrome is a relatively common genetic disorder and the second most common cause of congenital heart disease after trisomy 21. The spectrum of cardiac anomalies in Noonan syndrome typically involves pulmonary valve stenosis occasionally in conjunction with hypertrophic cardiomyopathy. Mitral valve involvement is a rare finding in Noonan syndrome and is most commonly associated with either mitral valve prolapse or abnormal valvular insertion causing left ventricular outflow tract obstruction. Patients with Noonan syndrome typically have preserved fertility and, given the success of cardiac surgery and medical management of heart failure in this population, are beginning to present more commonly as parturients in adulthood. Maternal physiologic changes during pregnancy introduce an added complexity to hemodynamic management and anesthetic considerations during labor and delivery. In this article, we present a case of a patient with Noonan syndrome with severe mitral stenosis, pulmonary valve insufficiency, and severe restrictive and obstructive pulmonary disease who presented preterm for delivery due to increased dyspnea at rest. Here we review the pathophysiology behind Noonan syndrome and peripartum management strategies in a patient with severe combined cardiac and pulmonary disease.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Pneumopatias Obstrutivas/complicações , Estenose da Valva Mitral/complicações , Síndrome de Noonan/complicações , Síndrome de Noonan/fisiopatologia , Complicações na Gravidez/fisiopatologia , Insuficiência da Valva Pulmonar/complicações , Adulto , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Cesárea , Dispneia/complicações , Dispneia/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Feminino , Humanos , Pneumopatias Obstrutivas/diagnóstico por imagem , Pneumopatias Obstrutivas/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/fisiopatologia , Gravidez , Nascimento Prematuro , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Ultrassonografia/métodos
19.
PLoS One ; 15(8): e0237193, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32780780

RESUMO

BACKGROUND: The myocardial adaptive mechanism in patients with repaired tetralogy of Fallot (rTOF) is less understood. We aimed to investigate biventricular myocardial adaptive remodeling in rTOF patients. METHODS: We recruited 32 rTOF patients and 38 age- and sex-matched normal controls. The pulmonary stenosis of rTOF patients was measured using catheterized pressure gradient between right ventricle (RV) and pulmonary artery (PGRVPA). rTOF patients with PGRVPA < 15 mmHg and ≥15 mmHg were classified as low pulmonary stenosis (rTOFlow, n = 19) and high pulmonary stenosis (rTOFhigh, n = 13) subgroups, respectively. Magnetic resonance imaging tissue phase mapping was employed to evaluate the voxelwise biventricular myocardial motion in longitudinal (Vz), radial (Vr), and circumferential (Vφ) directions. RESULTS: The rTOFlow subgroup presented higher pulmonary regurgitation fraction than rTOFhigh subgroup (p < 0.001). Compared with the normal group, only rTOFlow subgroup presented a decreased RV ejection fraction (RVEF) (p < 0.05). The rTOFlow subgroup showed decreased systolic and diastolic Vz in RV and LV, whereas rTOFhigh subgroup showed such change only in RV. In rTOFlow subgroup, RVEF significantly correlated with RV systolic Vr (r = 0.56, p < 0.05), whereas LVEF correlated with LV systolic Vz (r = 0.51, p = 0.02). Prolonged QRS correlated with RV systolic Vr (r = -0.58, p < 0.01) and LV diastolic Vr (r = 0.81, p < 0.001). No such correlations occurred in rTOFhigh subgroup. CONCLUSIONS: The avoidance of unfavorable functional interaction in RV and LV in rTOFhigh subgroup suggested that adequate pulmonary stenosis (PGRVPA ≥ 15 mmHg in this sereis) has a protective effect against pulmonary regurgitation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/reabilitação , Adulto , Pressão Sanguínea , Estudos de Casos e Controles , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Insuficiência da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/fisiopatologia , Volume Sistólico , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita , Adulto Jovem
20.
Can J Cardiol ; 36(12): 1978.e1-1978.e3, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32818557

RESUMO

Mucolipidosis type III α/ß is an autosomal recessive lysosomal storage disease, caused by the deficient activity of UDP-N-acetyl glucosamine-1-phosphotransferase. The resultant intralysosomal accumulation of partly degraded mucopolysaccharides and sphingolipids causes multiple-organ damage, including the heart. The most documented cardiac manifestation is the thickening and insufficiency of mitral and aortic valves, but there are very few reports about the myocardial involvement. We report a case with mucolipidosis type III α/ß complicated by marked dilatation and dysfunction of the right ventricle, which is quite rare and further broadens the clinical spectrum of the disease.


Assuntos
Insuficiência da Valva Aórtica , Cardiomegalia , Diuréticos/administração & dosagem , Ventrículos do Coração , Insuficiência da Valva Pulmonar , Disfunção Ventricular Direita , Adulto , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Cardiomegalia/diagnóstico por imagem , Cardiomegalia/etiologia , Dilatação Patológica , Ecocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Mucolipidoses/diagnóstico , Tamanho do Órgão , Administração dos Cuidados ao Paciente/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/fisiopatologia , Disfunção Ventricular Direita/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA