Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.413
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
BMC Pulm Med ; 24(1): 462, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39300424

RESUMO

BACKGROUND: Mechanical ventilation is crucial for patient management in intensive care units, but it comes with complications such as pressure ulcers and ventilator-associated pneumonia (VAP). The impact of head-of-bed elevation angles on these complications remains a critical area for investigation. METHODS: This systematic review and meta-analysis followed PRISMA guidelines and involved searches across PubMed, Embase, Web of Science, and Cochrane Library, conducted on September 19, 2023, with no date or language restrictions. We included randomized controlled trials that compared different head-of-bed elevation angles in adult ICU patients on mechanical ventilation. Data were extracted on study characteristics, quality assessed using the Cochrane risk of bias tool, and statistical analyses performed using chi-square tests for heterogeneity and fixed or random-effects models based on heterogeneity results. RESULTS: Six studies met inclusion criteria out of an initial 601 articles. These studies showed minimal heterogeneity (I2 = 0.0% for pressure ulcers, p = 0.930; and for VAP, p = 0.797), supporting the use of fixed-effect models. Results indicated that a higher elevation angle (45°) significantly increased the risk of pressure ulcers (OR = 1.95, 95% CI: 1.12-3.37, p < 0.05) and decreased the incidence of VAP compared to a lower angle (30°) (OR = 0.51, 95% CI: 0.31-0.84, p < 0.05). CONCLUSIONS: While higher head-of-bed elevation can reduce the risk of VAP in mechanically ventilated patients, it may increase the risk of pressure ulcers. Clinical strategies should carefully balance these outcomes to optimize patient care in ICU settings. REGISTRATION: PROSPERO 2024 CRD42024570232.


Assuntos
Unidades de Terapia Intensiva , Pneumonia Associada à Ventilação Mecânica , Úlcera por Pressão , Respiração Artificial , Humanos , Úlcera por Pressão/etiologia , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/epidemiologia , Respiração Artificial/efeitos adversos , Pneumonia Associada à Ventilação Mecânica/epidemiologia , Pneumonia Associada à Ventilação Mecânica/etiologia , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Leitos , Posicionamento do Paciente/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
J Wound Ostomy Continence Nurs ; 51(5): 382-388, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39313973

RESUMO

PURPOSE: The aim of the study was to determine the clinical value of using a powered alternating pressure air mattress (P-APAM) in the prevention of pressure injury (PI) in patients at medium to high risk. DESIGN: Noncomparative, observational study. SUBJECTS AND SETTING: The sample comprised 86 patients who were >18 years old, were classified as having medium to high risk of PI, had no PI at baseline, and were lying more than 15 hours a day on a specific P-APAM. Data were collected between September 2018 and July 2019, in 4 nursing homes, and 1 long-term care geriatrics hospital department in France. METHODS: In addition to guideline-based care for PI prevention, patients were followed up for 35 days following placement on the P-APAM. The main outcome was the percentage of patients who developed between day 0 and day 35 at least 1 PI of at least stage 2 on the sacrum, spine, or heel. Secondary outcomes were patient assessments of comfort, caregiver satisfaction, mattress noise level, and mattress safety. RESULTS: No patients experienced a PI (incidence = 0%; 95% confidence interval, 0.00%-4.28%). Patients were satisfied or very satisfied with the mattress in most cases in terms of comfort (77.9%) and stability (73.0%). Patients also rated the noise level of the mattress as satisfactory or very satisfactory in all cases (100%). CONCLUSION: When combined with guideline-based PI prevention measures, use of the P-APAM was associated with a low incidence of PI.


Assuntos
Leitos , Úlcera por Pressão , Humanos , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/epidemiologia , Masculino , Feminino , Leitos/normas , Leitos/estatística & dados numéricos , Idoso , Incidência , Idoso de 80 Anos ou mais , França/epidemiologia , Pessoa de Meia-Idade , Casas de Saúde/estatística & dados numéricos , Casas de Saúde/organização & administração , Casas de Saúde/normas , Desenho de Equipamento/normas , Desenho de Equipamento/métodos
3.
J Wound Care ; 33(9): 652-658, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39287027

RESUMO

OBJECTIVE: Pressure ulcers (PUs) severely impact health outcomes in neonatal intensive care, with up to 28% prevalence and doubled mortality rates. Due to their only partially developed stratum corneum, neonates are highly susceptible to PUs because of a lack of adequate support surfaces. The occipital region of the head and hip are the main risk areas due to immobility and newborn body proportions. The main goal of the study was to investigate the impact of reduction in local pressure in these body areas by two air mattress designs and different filling states. METHOD: Two innovative air-filled mattress prototypes (prototype 1 and prototype 2), consisting of three different segments (head, trunk and feet regions), were developed to reduce local interface pressures by optimising pressure distribution, and were assessed with three air pressure filling states (0.2kPa, 0.4kPa and 0.6kPa). A baby doll was used to investigate pressure distribution and local pressure impact. It measured 51cm and the weight was modified to be 1.3kg, 2.3kg and 3.3kg, representing premature to term newborn weights, respectively. A specialised foam mattress and an unsupported surface were considered as controls. RESULTS: The interface pressures at the hip region for newborn models could be reduced by up to 41% with mattress prototype 1 and 49% with prototype 2 when filled with 0.2kPa air pressure. It was found that the size and the pressure inside air segments was crucial for interface pressure. CONCLUSION: Our results demonstrated that air mattresses achieved lower interface pressures compared to conventional support surfaces, and that the benefit of the air mattresses depended on their filling status. The importance of using innovative, segmented designs that were tailored to meet the specific needs of highly vulnerable paediatric patients was demonstrated.


Assuntos
Leitos , Desenho de Equipamento , Úlcera por Pressão , Úlcera por Pressão/prevenção & controle , Humanos , Recém-Nascido , Pressão
4.
PLoS One ; 19(8): e0305625, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39088472

RESUMO

INTRODUCTION: Bedsharing is common but advised against by the American Academy of Pediatrics. It is unknown if breastfeeding physicians bedshare more or less than the general population. OBJECTIVES: To determine the prevalence of bedsharing among physicians, their reasons for bedsharing or not, and whether bedsharing was associated with a longer duration of breastfeeding. METHODS: An online survey was adapted from surveys administered by the Centers for Disease Control and Prevention. The survey was administered to physicians and medical students who birthed children from October 2020 through August 2021. Respondents were asked to report on a singleton birth, and questions centered around sleep practices and breastfeeding. Survival analysis was used to examine the association between bedsharing and breastfeeding duration. RESULTS: Of 546 respondents with bedsharing data, 68% reported some history of bedsharing, and 77% were in specialties that involved caring for pregnant people and/or infants. Those who bedshared breastfed an average of four months longer than those who never bedshared (18.08 versus 14.08 months p<0.001). The adjusted risk of breastfeeding cessation was markedly lower for those who bedshared compared to those who did not (Hazard Ratio 0.57, 95% Confidence Interval 0.45, 0.71). The primary reason for bedsharing was to breastfeed (73%); the primary reason for not bedsharing was safety concerns (92%). Among those who bedshared (n = 373), 52% did not inform their child's healthcare provider. CONCLUSIONS: Bedsharing is common among our sample of mainly breastfeeding physicians, including those who care for pregnant people and/or infants. It is also associated with a longer duration of breastfeeding, which has implications for population health. Practicing bedsharing implies cognitive dissidence and may affect how physicians counsel about bedsharing. Additionally, lack of disclosure of bedsharing practices has implications for practical guidance about having open non-judgmental conversations and may be a missed opportunity to counsel on bedsharing safety.


Assuntos
Aleitamento Materno , Médicos , Sono , Humanos , Aleitamento Materno/estatística & dados numéricos , Feminino , Médicos/estatística & dados numéricos , Médicos/psicologia , Inquéritos e Questionários , Masculino , Adulto , Pessoa de Meia-Idade , Lactente , Recém-Nascido , Leitos , Gravidez
5.
BMJ Case Rep ; 17(8)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134335

RESUMO

Fibrotic hypersensitivity pneumonitis (HP) has a poor prognosis when no antigen is identified, which occurs in many cases. We present a case of HP due to foam exposure in bedding, an unrecognised cause of HP. A woman was referred for dyspnoea and cough. High-resolution chest computed tomography (HRCT) showed a three-density pattern with gas trapping. Pulmonary function tests (PFTs) revealed restriction and reduced diffusing capacity. Bronchoalveolar lavage showed lymphocytosis (43%) and lung cryobiopsy showed fibrosis, lymphocytic infiltration and multinucleated giant cells. She had foam in mattress and pillows but no other exposures. Her symptoms, PFTs, and imaging improved after avoiding foam in her bedding. After re-exposure to a foam pillow, her symptoms, PFTs, and HRCT worsened. Microbiological analysis of the foam pillow reported Penicillium spp, known to cause HP. Foam exposure is a novel cause of HP, and foam avoidance can prevent disease progression and death.


Assuntos
Alveolite Alérgica Extrínseca , Roupas de Cama, Mesa e Banho , Penicillium , Tomografia Computadorizada por Raios X , Humanos , Alveolite Alérgica Extrínseca/etiologia , Alveolite Alérgica Extrínseca/diagnóstico , Feminino , Roupas de Cama, Mesa e Banho/efeitos adversos , Leitos/efeitos adversos , Testes de Função Respiratória , Pessoa de Meia-Idade , Pulmão/diagnóstico por imagem , Pulmão/patologia , Dispneia/etiologia
6.
Sensors (Basel) ; 24(15)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39123929

RESUMO

The transition from wakefulness to sleep occurs when the core body temperature decreases. The latter is facilitated by an increase in the cutaneous blood flow, which dissipates internal heat into the micro-environment surrounding the sleeper's body. The rise in cutaneous blood flow near sleep onset causes the distal (hands and feet) and proximal (abdomen) temperatures to increase by about 1 °C and 0.5 °C, respectively. Characterizing the dynamics of skin temperature changes throughout sleep phases and understanding its relationship with sleep quality requires a means to unobtrusively and longitudinally estimate the skin temperature. Leveraging the data from a temperature sensor strip (TSS) with five individual temperature sensors embedded near the surface of a smart bed's mattress, we have developed an algorithm to estimate the distal skin temperature with a minute-long temporal resolution. The data from 18 participants who recorded TSS and ground-truth temperature data from sleep during 14 nights at home and 2 nights in a lab were used to develop an algorithm that uses a two-stage regression model (gradient boosted tree followed by a random forest) to estimate the distal skin temperature. A five-fold cross-validation procedure was applied to train and validate the model such that the data from a participant could only be either in the training or validation set but not in both. The algorithm verification was performed with the in-lab data. The algorithm presented in this research can estimate the distal skin temperature at a minute-level resolution, with accuracy characterized by the mean limits of agreement [-0.79 to +0.79 °C] and mean coefficient of determination R2=0.87. This method may enable the unobtrusive, longitudinal and ecologically valid collection of distal skin temperature values during sleep. Therelatively small sample size motivates the need for further validation efforts.


Assuntos
Algoritmos , Leitos , Temperatura Cutânea , Sono , Temperatura Cutânea/fisiologia , Humanos , Sono/fisiologia , Masculino , Feminino , Adulto , Vigília/fisiologia , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(4): 413-418, 2024 Jul 30.
Artigo em Chinês | MEDLINE | ID: mdl-39155255

RESUMO

Nursing beds can be widely used in medical institutions and households to provide medical care for patients or disabled individuals. With the increasing demand for nursing, nursing beds are developing towards intelligence and comfort. In this study, the backrest lifting mechanism of nursing beds is selected as the research object. The standards for backrest angle adjustment and the basis for comfort judgment are reviewed, and the research on various adjustment configurations are sorted in order to provide assistance to relevant research institutions in understanding current technologies and assist users in making choices.


Assuntos
Leitos , Humanos , Desenho de Equipamento , Remoção , Movimentação e Reposicionamento de Pacientes/instrumentação
8.
BMC Pediatr ; 24(1): 509, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39118070

RESUMO

OBJECTIVE: To determine the effectiveness of phase-change-material mattress (PCM) during transportation of newborns with hypoxic ischemic encephalopathy (HIE). STUDY DESIGN: Randomized controlled trial of newborns with HIE from June 2016 to December 2019. Patients were randomized to transport with PCM or without PCM (control) when transferred to a cooling center in northern Vietnam. Primary outcome measure was mortality rate, secondary outcomes including temperature control and adverse effects. RESULT: Fifty-Two patients in PCM-group and 61 in control group. Median rectal temperature upon arrival was 34.5 °C (IQR 33.5-34.8) in PCM-group and 35.1 °C (IQR 34.5-35.9) in control group (p = 0.023). Median time from birth to reach target temperature was 5.0 ± 1.4 h and 5.5 ± 1.2 h in the respective groups (p = 0.065). 81% of those transported with PCM versus 62% of infants transported without (p = 0.049) had reached target temperature within the 6-h timeframe. There was no record of overcooling (< 32 °C) in any of the groups. The was no difference in mortality rate between the two groups (33% and 34% respectively (p > 0.05)). CONCLUSION: Phase-change-material can be used as a safe and effective cooling method during transportation of newborns with HIE in low-resource settings. TRIAL REGISTRATION: The study was retro-prospectively registered in Clinical Trials (04/05/2022, NCT05361473).


Assuntos
Leitos , Hipotermia Induzida , Hipóxia-Isquemia Encefálica , Transporte de Pacientes , Humanos , Hipóxia-Isquemia Encefálica/terapia , Hipóxia-Isquemia Encefálica/mortalidade , Recém-Nascido , Vietnã , Hipotermia Induzida/métodos , Feminino , Transporte de Pacientes/métodos , Masculino , Temperatura Corporal
9.
Sensors (Basel) ; 24(15)2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39123813

RESUMO

The analysis of biomedical signals is a very challenging task. This review paper is focused on the presentation of various methods where biomedical data, in particular vital signs, could be monitored using sensors mounted to beds. The presented methods to monitor vital signs include those combined with optical fibers, camera systems, pressure sensors, or other sensors, which may provide more efficient patient bed monitoring results. This work also covers the aspects of interference occurrence in the above-mentioned signals and sleep quality monitoring, which play a very important role in the analysis of biomedical signals and the choice of appropriate signal-processing methods. The provided information will help various researchers to understand the importance of vital sign monitoring and will be a thorough and up-to-date summary of these methods. It will also be a foundation for further enhancement of these methods.


Assuntos
Leitos , Sinais Vitais , Humanos , Sinais Vitais/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Processamento de Sinais Assistido por Computador , Sono/fisiologia
11.
Br J Hosp Med (Lond) ; 85(8): 1-13, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212554

RESUMO

Aims/Background Artificial intelligence technology has attained rapid development in recent years. The integration of artificial intelligence applications into pressure reduction mattresses, giving rise to artificial intelligence-powered pressure reduction mattresses, is expected to provide personalised intelligent pressure reduction solutions, through automatic user's data-based adjustment of the patient's local pressure condition to prevent pressure injury. The purpose of this study was to investigate the effectiveness of artificial intelligence-powered smart decompression in the prevention of postoperative medium- and high-risk pressure injury in middle-aged and elderly patients. Methods A total of 400 middle-aged and elderly patients admitted to our hospital from June 2021 to December 2023 were selected as study subjects. Patients were categorised into observation and control groups according to the medical record system. General demographic data of the patients were collected. The propensity score matching method was used to balance the baseline data of the two groups of patients. The incidence, severity, complications and sleep quality in the matched study subjects were also compared. Results After matching, there were 96 patients in the two groups, and the differences in baseline data between the two groups were not statistically significant. Pressure injury and the total incidence of complications in the observation group were significantly lower than those in the control group (p < 0.05). Before treatment, there was no difference in the scores of all aspects of the Richards Campbell Sleep Questionnaire between the two groups (p > 0.05). After treatment, the scores of all aspects of Richards Campbell Sleep Questionnaire in the observation group were significantly lower than those in the control group (p < 0.05). Conclusion The artificial intelligence-powered smart decompression mattress can significantly prevent moderate- and high-risk pressure injury, effectively reducing the incidence of pressure injury and complications in postoperative long-term bedridden patients, alleviating the severity of pressure injury, relieving the pressure on various parts, and improving the sleep quality of patients.


Assuntos
Inteligência Artificial , Leitos , Úlcera por Pressão , Humanos , Feminino , Masculino , Úlcera por Pressão/prevenção & controle , Úlcera por Pressão/etiologia , Úlcera por Pressão/epidemiologia , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Descompressão/métodos
12.
J Appl Biomech ; 40(5): 357-363, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39159922

RESUMO

The peak compressive forces at L5/S1 during patient transfers have been estimated. However, no study has considered the actual patient body weight that caregivers had to handle during transfers. We developed a simple kinematic model of lifting to address this limitation. Fifteen prospective health care providers transferred a 70-kg individual who mimicked a patient ("patient") from bed to wheelchair. Trials were acquired with the patient donning (weighted) and doffing (unweighted) a 5-kg weight belt. Trials were also acquired with and without knee assistance and a mechanical lift. During trials, kinematics and kinetics of transfers were recorded to estimate the peak compressive force at L5/S1 using static equilibrium equations. The peak compressive force was associated with the transfer method (P < .0005), and the compressive force was 68% lower in lift-assisted than manual transfer (2230 [SD = 433] N vs 6875 [SD = 2307] N). However, the peak compressive force was not associated with knee assistance, nor with a change in the patient body weight. Our results inform that mechanical loading exceeding the National Institute for Occupational Safety and Health safety criterion occurs during patient transfers, confirming a high risk of lower back injuries in caregivers. However, the risk can be mitigated with the use of a mechanical lift.


Assuntos
Movimentação e Reposicionamento de Pacientes , Cadeiras de Rodas , Humanos , Fenômenos Biomecânicos , Masculino , Feminino , Leitos , Adulto , Estudos Prospectivos , Força Compressiva , Suporte de Carga
13.
Sensors (Basel) ; 24(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-39000837

RESUMO

Sleep quality is an important issue of public concern. This study, combined with sensor application, aims to explore the determinants of perceived comfort when using smart bedding to provide empirical evidence for improving sleep quality. This study was conducted in a standard sleep laboratory in Quanzhou, China, from March to April of 2023. Perceived comfort was evaluated using the Subjective Lying Comfort Evaluation on a seven-point rating scale, and body pressure distribution was measured using a pressure sensor. Correlation analysis was employed to analyze the relationship between perceived comfort and body pressure, and multiple linear regression was used to identify the factors of perceived comfort. The results showed that body pressure was partially correlated with perceived comfort, and sleep posture significantly influenced perceived comfort. In addition, height, weight, and body mass index are common factors that influence comfort. The findings highlight the importance of optimizing the angular range of boards based on their comfort performance to adjust sleeping posture and equalize pressure distribution. Future research should consider aspects related to the special needs of different populations (such as height and weight), as well as whether users are elderly and whether they have particular diseases. The design optimization of the bed board division and mattress softness, based on traditional smart bedding, can improve comfort and its effectiveness in reducing health risks and enhancing health status.


Assuntos
Roupas de Cama, Mesa e Banho , Humanos , Masculino , Feminino , Adulto , Postura/fisiologia , Qualidade do Sono , Leitos , China , Sono/fisiologia , Desenho de Equipamento , Adulto Jovem , Pessoa de Meia-Idade , Pressão
14.
PLoS One ; 19(7): e0306773, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38990820

RESUMO

INTRODUCTION: Since its creation in the 18th century, bedpan has remained more or less the same. Its unique material composition varies from one model to another, but its shape remains relatively similar. The environment is one of the four pillars of the nursing paradigm. It is therefore essential to question this device in the nursing discipline. AIM: To assess perceived patient comfort and ease of bedpan handling by nurses and their assistants. METHOD: A cross-sectional survey via an online questionnaire was conducted among nurses and nursing assistants, nursing students, and health executives using the bedpan for their patients to assess their feelings and their level of satisfaction. The questionnaire asks professionals about the ease of handling the bedpan and the patient's perceived comfort. RESULTS: 431 responses were obtained out of 3007 persons interviewed (14.3%). 83.0% believe that the cause of poor elimination by the patient is often or very often due to physical discomfort on the bedpan. 62.6% find the installation of the bedpan rather tough or very difficult. 59.2% find the removal of the bedpan rather tough or very difficult. DISCUSSION: Our study confirms our hypothesis and highlights a lack of comfort in the bedpan as perceived by professionals. This analysis is the first step in enabling the nurse researcher to support change in the transformation paradigm.


Assuntos
Conforto do Paciente , Humanos , Estudos Transversais , Inquéritos e Questionários , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Cuidadores/psicologia , Enfermeiras e Enfermeiros/psicologia , Adulto Jovem , Assistentes de Enfermagem/psicologia , Leitos
15.
Int Wound J ; 21(7): e14957, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38994923

RESUMO

Prolonged mechanical loading of the skin and underlying soft tissue cause pressure ulceration. The use of special support surfaces are key interventions in pressure ulcer prevention. They modify the degree and duration of soft tissue deformation and have an impact on the skin microclimate. The objective of this randomized cross-over trial was to compare skin responses and comfort after lying for 2.5 h supine on a support surface with and without a coverlet that was intended to assist with heat and moisture removal at the patient/surface interface. In addition, physiological saline solution was administered to simulate an incontinence episode on the mattress next to the participants' skin surface. In total, 12 volunteers (mean age 69 years) with diabetes mellitus participated. After loading, skin surface temperature, stratum corneum hydration and skin surface pH increased, whereas erythema and structural stiffness decreased at the sacral area. At the heel skin area, temperature, erythema, and stratum corneum hydration increased. These results indicate occlusion and soft tissue deformation which was aggravated by the saline solution. The differences in skin response showed only minor differences between the support surface with or without the coverlet.


Assuntos
Leitos , Estudos Cross-Over , Calcanhar , Úlcera por Pressão , Humanos , Idoso , Úlcera por Pressão/prevenção & controle , Masculino , Feminino , Pessoa de Meia-Idade , Suporte de Carga/fisiologia , Idoso de 80 Anos ou mais , Temperatura Cutânea/fisiologia
16.
Sci Rep ; 14(1): 15238, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38956282

RESUMO

The vector forces at the human-mattress interface are not only crucial for understanding the distribution of vertical and shear forces exerted on the human body during sleep but also serves as a significant input for biomechanical models of sleeping positions, whose accuracy determines the credibility of predicting musculoskeletal system loads. In this study, we introduce a novel method for calculating the interface vector forces. By recording indentations after supine and lateral positions using a vacuum mattress and 3D scanner, we utilize image registration techniques to align body pressure distribution with the mattress deformation scanning images, thereby calculating the vector force values for each unit area (36.25 mm × 36.25 mm). This method was validated through five participants attendance from two perspectives, revealing that (1) the mean summation of the vertical force components is 98.67% ± 7.21% body weight, exhibiting good consistency, and mean ratio of horizontal component force to body weight is 2.18% ± 1.77%. (2) the predicted muscle activity using the vector forces as input to the sleep position model aligns with the measured muscle activity (%MVC), with correlation coefficient over 0.7. The proposed method contributes to the vector force distribution understanding and the analysis of musculoskeletal loads during sleep, providing valuable insights for mattress design and evaluation.


Assuntos
Leitos , Sono , Humanos , Sono/fisiologia , Masculino , Fenômenos Biomecânicos , Adulto , Feminino , Postura/fisiologia , Adulto Jovem , Imageamento Tridimensional/métodos
17.
Attach Hum Dev ; 26(5): 403-422, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39033345

RESUMO

Bed-sharing is a controversial but common parenting practice with claimed benefits for emotional and behavioral development. Using data from the UK Millennium Cohort Study (N = 16,599), this prospective study investigated whether bed-sharing at 9 months is associated with childhood internalizing and externalizing symptom trajectories. Children were grouped by their patterns of co-developing internalizing and externalizing symptoms from 3 to 11 years of age using a parallel process latent class growth analysis. There were no associations between bed-sharing at 9 months of age and internalizing and externalizing symptom trajectories across childhood. This finding suggests that bed-sharing at 9 months has no positive or negative influence on the development of internalizing and externalizing symptoms across childhood. Clinicians should inform parents that bed-sharing during the second half of the first year is unlikely to have an impact on the later emotional and behavioral development of the children.


Assuntos
Comportamento Infantil , Humanos , Feminino , Masculino , Pré-Escolar , Criança , Estudos Prospectivos , Lactente , Reino Unido , Comportamento Infantil/psicologia , Poder Familiar/psicologia , Leitos , Desenvolvimento Infantil
18.
IEEE J Biomed Health Inform ; 28(6): 3379-3388, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38843069

RESUMO

Monitoring in-bed pose estimation based on the Internet of Medical Things (IoMT) and ambient technology has a significant impact on many applications such as sleep-related disorders including obstructive sleep apnea syndrome, assessment of sleep quality, and health risk of pressure ulcers. In this research, a new multimodal in-bed pose estimation has been proposed using a deep learning framework. The Simultaneously-collected multimodal Lying Pose (SLP) dataset has been used for performance evaluation of the proposed framework where two modalities including long wave infrared (LWIR) and depth images are used to train the proposed model. The main contribution of this research is the feature fusion network and the use of a generative model to generate RGB images having similar poses to other modalities (LWIR/depth). The inclusion of a generative model helps to improve the overall accuracy of the pose estimation algorithm. Moreover, the method can be generalized for situations to recover human pose both in home and hospital settings under various cover thickness levels. The proposed model is compared with other fusion-based models and shows an improved performance of 97.8% at PCKh @0.5. In addition, performance has been evaluated for different cover conditions, and under home and hospital environments which present improvements using our proposed model.


Assuntos
Redes Neurais de Computação , Postura , Humanos , Postura/fisiologia , Aprendizado Profundo , Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Leitos
19.
PeerJ ; 12: e17570, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38903879

RESUMO

Objectives: This study sought to evaluate the diagnostic value of a non-contact optical fiber mattress for apnea and hypopnea and compare it with traditional polysomnography (PSG) in adult obstructive sleep apnea hypopnea syndrome (OSAHS). Methods: To determine the value of a non-contact optical fiber mattress for apnea and hypopnea, six healthy people and six OSAHS patients were selected from Tongji Hospital to design a program to identify apnea or hypopnea. A total of 108 patients who received polysomnography for drowsiness, snoring or other suspected OSAHS symptoms. All 108 patients were monitored with both the non-contact optical fiber mattress and PSG were collected. Results: Six healthy controls and six patients with OSAHS were included. The mean apnea of the six healthy controls was 1.22 times/h, and the mean hypopnea of the six healthy controls was 2 times/h. Of the six patients with OSAHS, the mean apnea was 12.63 times/h, and the mean hypopnea was 19.25 times/h. The non-contact optical fiber mattress results showed that the mean apnea of the control group was 3.17 times/h and the mean hypopnea of the control group was 3.83 times/h, while the mean apnea of the OSAHS group was 11.95 times/h and the mean hypopnea of the OSAHS group was 17.77 times/h. The apnea index of the non-contact optical fiber mattress was positively correlated with the apnea index of the PSG (P < 0.05, r = 0.835), and the hypopnea index of the non-contact optical fiber mattress was also positively correlated with the hypopnea index of the PSG (P < 0.05, r = 0.959). The non-contact optical fiber mattress had high accuracy (area under curve, AUC = 0.889), specificity (83.4%) and sensitivity (83.3%) for the diagnosis of apnea. The non-contact fiber-optic mattress also had high accuracy (AUC = 0.944), specificity (83.4%) and sensitivity (100%) for the diagnosis of hypopnea. Among the 108 patients enrolled, there was no significant difference between the non-contact optical fiber mattress and the polysomnography monitor in total recording time, apnea hypopnea index (AHI), average heart rate, tachycardia index, bradycardia index, longest time of apnea, average time of apnea, longest time of hypopnea, average time of hypopnea, percentage of total apnea time in total sleep time and percentage of total hypopnea time in total sleep time. The AHI value of the non-contact optical fiber mattress was positively correlated with the AHI value of the PSG (P < 0.05, r = 0.713). The specificity and sensitivity of the non-contact optical fiber mattress AHI in the diagnosis of OSAHS were 95% and 93%, with a high OSAHS diagnostic accuracy (AUC = 0.984). Conclusion: The efficacy of the non-contact optical fiber mattress for OSAHS monitoring was not significantly different than PSG monitoring. The specificity of the non-contact optical mattress for diagnosing OSAHS was 95% and its sensitivity was 93%, with a high OSAHS diagnostic accuracy.


Assuntos
Fibras Ópticas , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/diagnóstico , Masculino , Polissonografia/instrumentação , Polissonografia/métodos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Leitos , Sensibilidade e Especificidade , Estudos de Casos e Controles , Idoso
20.
Trials ; 25(1): 376, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38863018

RESUMO

BACKGROUND: Intensive care medicine continues to improve, with advances in technology and care provision leading to improved patient survival. However, this has not been matched by similar advances in ICU bedspace design. Environmental factors including excessive noise, suboptimal lighting, and lack of natural lights and views can adversely impact staff wellbeing and short- and long-term patient outcomes. The personal, social, and economic costs associated with this are potentially large. The ICU of the Future project was conceived to address these issues. This is a mixed-method project, aiming to improve the ICU bedspace environment and assess impact on patient outcomes. Two innovative and adaptive ICU bedspaces capable of being individualised to patients' personal and changing needs were co-designed and implemented. The aim of this study is to evaluate the effect of an improved ICU bedspace environment on patient outcomes and operational impact. METHODS: This is a prospective multi-component, mixed methods study including a randomised controlled trial. Over a 2-year study period, the two upgraded bedspaces will serve as intervention beds, while the remaining 25 bedspaces in the study ICU function as control beds. Study components encompass (1) an objective environmental assessment; (2) a qualitative investigation of the ICU environment and its impact from the perspective of patients, families, and staff; (3) sleep investigations; (4) circadian rhythm investigations; (5) delirium measurements; (6) assessment of medium-term patient outcomes; and (7) a health economic evaluation. DISCUSSION: Despite growing evidence of the negative impact the ICU environment can have on patient recovery, this is an area of critical care medicine that is understudied and commonly not considered when ICUs are being designed. This study will provide new information on how an improved ICU environment impact holistic patient recovery and outcomes, potentially influencing ICU design worldwide. TRIAL REGISTRATION: ACTRN12623000541606. Registered on May 22, 2023. https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=385845&isReview=true .


Assuntos
Unidades de Terapia Intensiva , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Estudos Prospectivos , Fatores de Tempo , Leitos , Resultados de Cuidados Críticos , Ambiente de Instituições de Saúde , Arquitetura Hospitalar , Cuidados Críticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA