Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Chemosphere ; 364: 143028, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39111672

RESUMO

The widespread usage of levofloxacin (LVF) intake is executed for several urinary and respiratory systems infections in human. But, its over intake leads to severe damage to humans and the environment by its exposure. Hence the detection of LVF is concerned and we herein developed an electrocatalyst, strontium tungsten oxide nanospheres and later decorated onto the functionalized multiwall carbon nanotubes (SrWO4/f-MWCNT) to perform effective electrochemical recognition of LVF in aquatic and biological samples. Binary metal oxide with carbon composite SrWO4/f-MWCNT was developed due to its specific features as nanostructures. Various methods of investigation have been examined to identify the physiochemical characteristics like X-ray diffraction, Raman spectroscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and morphological characteristics including field emission scanning electron microscopy, and transmission electron microscopy. The synthesized SrWO4/f-MWCNT sample crystalline size was around 32.9 nm. The SrWO4/f-MWCNT modified glassy carbon electrode (GCE) has been subjected to electrochemical investigation with a wide linear range of 0.049 µM-574.73 µM with good sensitivity 2.86 µA µM-1 cm2, the limit of detection at 14.9 nM for LVF sensing. Furthermore, the designed LVF detection exhibited excellent anti-interference, stability, reproducibility, and repeatability. The as-developed sensor's electrochemical outcomes indicate the superior performance inherent in the developed composite.


Assuntos
Técnicas Eletroquímicas , Levofloxacino , Nanotubos de Carbono , Compostos de Tungstênio , Nanotubos de Carbono/química , Levofloxacino/química , Levofloxacino/análise , Levofloxacino/urina , Compostos de Tungstênio/química , Técnicas Eletroquímicas/métodos , Catálise , Eletrodos , Limite de Detecção , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/química , Óxidos/química , Tungstênio/química
2.
Anal Methods ; 16(35): 6011-6019, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39171860

RESUMO

The potential impact on human health and the environment has spurred significant interest in detecting and quantifying pharmaceutical compounds across various matrices, from environmental to biological samples. Here, we present an electrochemical approach for determining levofloxacin in drug, synthetic urine, water, and breast milk samples. An affordable sensor was constructed using 3D printing and composite material based on nail polish, graphite, and aluminum oxide. The conductive composite material was characterized spectroscopically, electrochemically, and by imaging techniques. Subsequently, an electrochemical method based on square wave voltammetry was optimized and applied. The method exhibited good sensitivity (5.11 ± 0.0912 µA L µmol-1 cm-2) and enhanced stability (RSD = 7.2%), with electrochemical responses correlating with the concentration of levofloxacin in the samples tested, yielding recovery values in the range of 98 to 111%. The developed method demonstrated a robust linear working range from 2 to 100 µmol L-1 and a nanomolar detection limit of 128 nmol L-1, rendering it suitable for quantitative analysis. The sensor also shows promise as a platform for the sensitive detection of pharmaceutical compounds, contributing to greater safety and sustainability in these domains.


Assuntos
Óxido de Alumínio , Técnicas Eletroquímicas , Eletrodos , Grafite , Levofloxacino , Grafite/química , Levofloxacino/análise , Humanos , Óxido de Alumínio/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Limite de Detecção , Análise Custo-Benefício , Impressão Tridimensional , Unhas/química , Antibacterianos/análise
3.
Talanta ; 280: 126763, 2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39208680

RESUMO

Norfloxacin (NOR) and levofloxacin (LEV) are the two most frequently used fluoroquinolones (FQs) in clinic. Their residues seriously endanger the ecosystem and human health. Due to their similarity in structure and properties, it is urgent to develop an efficient and sensitive strategy for detection and differentiation. Herein, we synthesized a novel ratiometric fluorescent sensor for the first time by combining N, S co-doped carbon dots (CDs) and the precursors of Tb-MOFs through a facile one-pot method. The introduction of CDs effectively facilitated the energy transfer between Tb3+ and FQs, overcoming the limitation that single Tb-MOFs could not identify similar antibiotics. Specifically, the presence of NOR resulted in reverse signal response through the inner filter effect and antenna effect. The synergistic effect of these two mechanisms contributed to achieving signal amplification accompanied by a distinguishable color transition. The limit of detection (LOD) was 0.036 µM. Different from NOR, the addition of LEV reduced the electron density of the system, weakened the coordination ability of Tb3+ with LEV, and induced a single signal response with Tb3+ fluorescence intensity as a reference signal (LOD = 0.383 µM). Furthermore, the method proved to be rapid and visual, allowing for the straightforward analysis of FQs residues in water, food matrices, and biological samples with satisfactory precision. By integrating N, S-CDs@Tb-MOFs with flexible substrates, the paper-based sensor facilitated the visual quantitative determination of FQs by reading RGB values. The developed sensor presents a promising strategy for the identification and real-time monitoring of antibiotics.


Assuntos
Carbono , Corantes Fluorescentes , Levofloxacino , Norfloxacino , Pontos Quânticos , Espectrometria de Fluorescência , Térbio , Norfloxacino/análise , Norfloxacino/química , Levofloxacino/análise , Levofloxacino/química , Carbono/química , Pontos Quânticos/química , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes/química , Térbio/química , Limite de Detecção , Humanos , Antibacterianos/análise , Antibacterianos/química , Fluorescência
4.
Food Chem ; 460(Pt 2): 140688, 2024 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-39089027

RESUMO

As the contamination and enrichment in food chain of levofloxacin (LV) antibiotics have caused a significant threat to life safety, the instant detection of LV has become an urgent need. Here, a PDI-functionalized imine-based covalent organic framework (PDI-COF300) was prepared by the electrostatic self-assembly method as fluorescent probe for smartphone visual detection of LV, which exhibited excellent fluorescence quantum yield (82.68%), greater stability, high sensitivity with detection limit of 0.303 µM. Based on the results of molecular docking and Stern-Volmer equation, the LV detection by PDI-COF300 was mainly a static quenching process through π-π stacked hydrophobic interactions and fluorescence resonance energy transfer. Besides, PDI-COF300 was applied to LV detection in environmental medium and milk samples with recoveries from 85.56% to 108.34% and relative standard deviations <2.70%. This work also provided a new general strategy for using PDI-COF in smartphone devices and fluorescent papers for LV fluorescence detection and microanalysis.


Assuntos
Iminas , Levofloxacino , Smartphone , Levofloxacino/química , Levofloxacino/análise , Iminas/química , Estruturas Metalorgânicas/química , Leite/química , Animais , Limite de Detecção , Corantes Fluorescentes/química , Contaminação de Alimentos/análise , Antibacterianos/análise , Antibacterianos/química , Simulação de Acoplamento Molecular , Espectrometria de Fluorescência
5.
Langmuir ; 40(24): 12671-12680, 2024 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-38853520

RESUMO

The design of single-atom nanozymes with dual active sites to increase their activity and for the detection and degradation of contaminants is rare and challenging. In this work, a single-atom nanozyme (FeCu-NC) based on a three-dimensional porous Fe/Cu dual active site was developed as a colorimetric sensor for both the quantitative analysis of isoniazid (INH) and the efficient degradation of levofloxacin (LEV). FeCu-NC was synthesized using a salt template and freeze-drying method with a three-dimensional hollow porous structure and dual active sites (Fe-Nx and Cu-Nx). In terms of morphology and structure, FeCu-NC exhibits excellent peroxidase-like activity and catalytic properties. Therefore, a colorimetric sensor was constructed around FeCu-NC for sensitive and rapid quantitative analysis of INH with a linear range of 0.9-10 µM and a detection limit as low as 0.3 µM, and the sensor was successfully applied to the analysis of INH in human urine. In addition, FeCu-NC promoted the efficient degradation of LEV by peroxymonosulfate activation, with a degradation rate of 90.4% for LEV at 30 min. This work sheds new light on the application of single-atom nanozymes to antibiotics for colorimetric sensing and degradation.


Assuntos
Cobre , Ferro , Isoniazida , Levofloxacino , Isoniazida/química , Isoniazida/análise , Levofloxacino/urina , Levofloxacino/análise , Levofloxacino/química , Ferro/química , Cobre/química , Humanos , Peroxidase/química , Peroxidase/metabolismo , Colorimetria/métodos , Nanoestruturas/química , Catálise
6.
Carbohydr Polym ; 340: 122306, 2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-38858025

RESUMO

In this study, a novel hydrogel, ß-cyclodextrin/carbon dots-grafted cellulose nanofibrils hydrogel (ßCCH), was fabricated for removal and fluorescence determination of levofloxacin (LEV). A comprehensive analysis was performed to characterize its physicochemical properties. Batch adsorption experiments were conducted, revealing that ßCCH reached a maximum adsorption capacity of 1376.9 mg/g, consistent with both Langmuir and pseudo-second-order models, suggesting that the adsorption process of LEV on ßCCH was primarily driven by chemical adsorption. The removal efficiency of ßCCH was 99.2 % under the fixed conditions (pH: 6, initial concentration: 20 mg/L, contact time: 300 min, temperature: 25 °C). The removal efficiency of ßCCH for LEV still achieved 97.3 % after five adsorption-desorption cycles. By using ßCCH as a fluorescent probe for LEV, a fast and sensitive method was established with linear ranges of 1-120 mg/L and 0.2-1.0 µg/L and a limit of detection (LOD) as low as 0.09 µg/L. The viability of ßCCH was estimated based on the economic analysis of the synthesis process and the removal of LEV, demonstrating that ßCCH was more cost-effective than commercial activated carbon. This study provides a novel approach for preparing a promising antibiotic detection and adsorption material with the advantages of stability, and cost-effectiveness.


Assuntos
Carbono , Celulose , Hidrogéis , Levofloxacino , Nanofibras , beta-Ciclodextrinas , Levofloxacino/análise , Levofloxacino/química , beta-Ciclodextrinas/química , Celulose/química , Adsorção , Nanofibras/química , Carbono/química , Hidrogéis/química , Antibacterianos/análise , Antibacterianos/química , Limite de Detecção , Poluentes Químicos da Água/análise , Corantes Fluorescentes/química , Pontos Quânticos/química , Fluorescência
7.
Inorg Chem ; 63(18): 8336-8341, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38651971

RESUMO

A cube-like Zn(II)-Eu(III) nanocluster 1 (molecular sizes: 1.8 × 2.0 × 2.0 nm) was constructed by the use of a new long-chain Schiff base ligand. It shows a ratiometric fluorescence response to levofloxacin (LFX) with high sensitivity and selectivity, which can be expressed as I615 nm/I550 nm = A*[LFX]2 + B*[LFX] + C. It is used to quantitatively detect the LFX concentrations in fetal calf serum (FCS) and tablets sold in pharmacy. Filter paper strips bearing 1 can be used to qualitatively detect LFX by a color change to red under a UV lamp. 1 and its hybrid with sodium alginate (SA), 1@SA, display potential applications in the qualitative detection of LFX in FCS and the medicine. The limit of detection of 1 to LFX is as low as 2.1 × 10-2 nM.


Assuntos
Alginatos , Európio , Levofloxacino , Zinco , Alginatos/química , Zinco/química , Zinco/sangue , Levofloxacino/sangue , Levofloxacino/análise , Európio/química , Espectrometria de Fluorescência , Animais , Humanos , Bovinos , Comprimidos , Corantes Fluorescentes/química
8.
Int J Biol Macromol ; 267(Pt 1): 131321, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38570001

RESUMO

The improper usage of levofloxacin (LEV) endangers both environmental safety and human public health. Therefore, trace analysis and detection of LEV have extraordinary significance. In this paper, a novel molecularly imprinted polymer (MIP) electrochemical sensor was developed for the specific determination of LEV by electrochemical polymerization of o-phenylenediamine (o-PD) using poly(3,4-ethylenedioxythiophene)/chitosan (PEDOT/CS) with a porous structure and rich functional groups as a carrier and LEV as a template molecule. The morphology, structure and properties of the modified materials were analyzed and studied. The result showed that the electron transfer rate and the electroactive strength of the electrode surface are greatly improved by the interconnection of PEDOT and CS. Meanwhile, PEDOT/CS was assembled by imprinting with o-PD through non-covalent bonding, which offered more specific recognition sites and a larger surface area for the detection of LEV and effectively attracted LEV through intermolecular association. Under the optimized conditions, MIP/PEDOT/CS/GCE showed good detection performance for LEV in a wide linear range of 0.0019- 1000 µM, with a limit of detection (LOD, S/N = 3) of 0.4 nM. Furthermore, the sensor has good stability and selectivity, and exhibits excellent capabilities in the microanalysis of various real samples.


Assuntos
Compostos Bicíclicos Heterocíclicos com Pontes , Quitosana , Técnicas Eletroquímicas , Levofloxacino , Impressão Molecular , Polímeros Molecularmente Impressos , Polímeros , Quitosana/química , Levofloxacino/análise , Levofloxacino/química , Polímeros/química , Compostos Bicíclicos Heterocíclicos com Pontes/química , Impressão Molecular/métodos , Técnicas Eletroquímicas/métodos , Polímeros Molecularmente Impressos/química , Eletrodos , Limite de Detecção , Humanos
9.
Chemosphere ; 355: 141763, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522672

RESUMO

The fluoroquinolones ciprofloxacin, danofloxacin, enoxacin, levofloxacin and lomefloxacin, occur in water bodies worldwide and therefore pose a threat to the aquatic environment. Advanced purification procedures, such as electrochemical oxidation, may act as a remedy since they contribute to eliminating contaminants and prevent micropollutants from entering open water bodies. By electrochemical treatment in a micro-flow reactor equipped with a boron-doped diamond (BDD) electrode, the fluoroquinolones were efficiently degraded. A total of 15 new products were identified using high-performance high-resolution chromatography coupled with high-resolution multifragmentation mass spectrometry. The ecotoxicity of the emerging transformation products was estimated through in silico quantitative structure activity relationship analysis. Almost all transformation products were predicted less ecotoxic than the initial compounds. The fluoroquinolone degradation followed three major mechanisms depending on the voltage during the electrochemical oxidation. At approximately 1 V, the reactions started with the elimination of molecular hydrogen from the piperazine moiety. At approx. 1.25 V, methyl and methylene groups were eliminated. At 1.5 V, hydroxyl radicals, generated at the BDD electrode, led to substitution at the piperazine ring. This novel finding of the three reactions depending on voltage contributes to the mechanistic understanding of electrochemical oxidation as potential remedy against fluoroquinolones in the aquatic environment.


Assuntos
Ciprofloxacina , Poluentes Químicos da Água , Ciprofloxacina/química , Levofloxacino/análise , Enoxacino/análise , Diamante/química , Fluoroquinolonas/análise , Piperazina , Oxirredução , Eletrodos , Água , Poluentes Químicos da Água/análise
10.
Huan Jing Ke Xue ; 45(3): 1468-1479, 2024 Mar 08.
Artigo em Chinês | MEDLINE | ID: mdl-38471862

RESUMO

Pharmaceuticals and personal care products (PPCPs) are a group of emerging contaminants causing detrimental effects on aquatic living organisms even at low doses. To investigate the contamination characteristics and ecological risks of PPCPs in drains flowing into the Yellow River of Ningxia, 21 PPCPs were detected and analyzed using solid phase extraction and ultra-high performance liquid chromatography-mass spectrometry in this study. All 21 targeted compounds were detected in the drains, with total concentrations ranging from 47.52 to 1 700.96 ng·L-1. Ciprofloxacin, acetaminophen, benzophenone-3, and diethyltoluamide were the more commonly detected compounds, with detection frequencies exceeding 80%. The five highest-concentration PPCPs were acetaminophen, diethyltoluamide, caffeine, benzophenone-3, and levofloxacin, with the maximum concentrations of 597.21, 563.23, 559.00, 477.28, and 473.07 ng·L-1, respectively. Spatial analysis showed that the pollution levels of PPCPs in the drains of the four cities were different, with average concentrations of ∑PPCPs in the order of Yinchuan>Shizuishan>Wuzhong>Zhongwei. The total concentration of PPCPs before flowing into the Yellow River ranged from 124.82 to 1 046.61 ng·L-1. Source analysis showed that livestock and poultry breeding wastewater was the primary source for sulfadiazine and oxytetracycline, whereas medical wastewater was the primary source for levofloxacin and ciprofloxacin. The primary sources of triclocarban and triclosan were domestic sewage and industrial wastewater, whereas the primary source of caffeine and diethyltoluamide was domestic sewage. The pollution of diciofenac, cimetidine, triclocarban, and triclosan in the drains was positively correlated with the regional population and economic development level. The ecological risk assessment indicated that levofloxacin, diclofenac, gemfibrozil, benzophenone-3, and triclocarban posed high risks to aquatic organisms in drains flowing into the Yellow River. It is worthwhile to consider the mixture risk of the PPCPs that exhibited high risk at most sampling sites.


Assuntos
Benzofenonas , Carbanilidas , Cosméticos , Triclosan , Poluentes Químicos da Água , Acetaminofen , Organismos Aquáticos , Cafeína/análise , Ciprofloxacina , Cosméticos/análise , Monitoramento Ambiental/métodos , Levofloxacino/análise , Preparações Farmacêuticas , Medição de Risco , Rios/química , Esgotos/análise , Águas Residuárias , Poluentes Químicos da Água/análise
11.
J Environ Manage ; 354: 120329, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38373375

RESUMO

Microplastics (MPs) usually appear in the aquatic environment as complex pollutants in combination with other environmental pollutants, such as levofloxacin (LVFX). After a 45-day exposure to LVFX and MPs with different particle sizes at environmental levels, LVFX was neurotoxic to Rana nigromaculata tadpoles. The order of the effects of the exposure treatment on tadpole behavior was: LVFX-MP3>LVFX-MP1>LVFX-MP2 ≥ LVFX. Results of transcriptome analysis of tadpole brain tissue showed that LVFX in combination with 0.10 and 10.00 µm MP interferes with the nervous system through the cell adhesion molecules pathway. Interestingly, the order of effects of the co-exposure on oxidative stress in the intestine was inconsistent with that of tadpole behavior. We found that Paraacteroides might be a microplastic indicator species for the gut microbiota of aquatic organisms. The results of the targeted metabolism of neurotransmitters in the intestine suggest that in the LVFX-MP2 treatment, LVFX alleviated the intestinal microbiota disorder caused by 1.00 µm MP, by regulating intestinal microbiota participating in the TCA cycle VI and gluconeogenesis and tetrapyrrole biosynthesis I, while downregulating Met and Orn, and upregulating 5HIAA, thereby easing the neurotoxicity to tadpoles exposed to LVFX-MP2. This work is of great significance for the comprehensive assessment of the aquatic ecological risks of microplastics-antibiotic compound pollutants.


Assuntos
Poluentes Ambientais , Poluentes Químicos da Água , Animais , Levofloxacino/análise , Microplásticos/toxicidade , Plásticos , Tamanho da Partícula , Intestinos/química , Encéfalo , Ranidae , Poluentes Ambientais/análise , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/análise
12.
J Environ Manage ; 344: 118718, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37541001

RESUMO

Antibiotic-containing wastewater is a typical biochemical refractory organic wastewater and general treatment methods cannot effectively and quickly degrade the antibiotic molecules. In this study, a novel boron-doped diamond (BDD) pulse electrochemical oxidation (PEO) technology was proposed for the efficient removal of levofloxacin (LFXN) from wastewater. The effects of current density (j), initial pH (pH0), frequency (f), electrolyte types and initial concentration (c0(LFXN)) on the degradation of LFXN were systematically investigated. The degradation kinetics under four different processes have also been studied. The possible degradation mechanism of LFXN was proposed by Density functional theory calculation and analysis of degradation intermediates. The results showed that under the optimal parameters, the COD removal efficiency (η(COD)) was 94.4% and the energy consumption (EEC) was 81.43 kWh·m-3 at t = 120 min. The degradation of LFXN at pH = 2.8/c(H2O2) followed pseudo-first-order kinetics. The apparent rate constant was 1.33 × 10-2 min-1, which was much higher than other processes. The degradation rate of LFXN was as follows: pH = 2.8/c(H2O2) > pH = 2.8 > pH = 7/c(H2O2) > pH = 7. Ten aromatic intermediates were formed during the degradation of LFXN, which were further degraded to F-, NH4+, NO3-, CO2 and H2O. This study provides a promising approach for efficiently treating LFXN antibiotic wastewater by pulsed electrochemical oxidation with a BDD electrode without adding H2O2.


Assuntos
Águas Residuárias , Poluentes Químicos da Água , Antibacterianos , Levofloxacino/análise , Peróxido de Hidrogênio , Poluentes Químicos da Água/química , Boro/química , Diamante/química , Oxirredução , Eletrodos
13.
Sci Total Environ ; 862: 160773, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36509275

RESUMO

Levofloxacin (LEV) is prone to be retained in aquifers due to its strong adsorption affinity onto sand, thus posing a threat to groundwater quality. In-situ injection technology for remediating LEV-contaminated soil and groundwater is still challenging owing to the lack of appropriate remedial agents. Herein, two novel multi-component porous covalent-organic polymers (namely, SLEL-1 and SLEL-2) with alkyl chains were constructed through Schiff-base reactions to adsorb LEV from an aqueous solution, in which the kinetics, isotherms, influenced factors were investigated. Plausible adsorption mechanisms were proposed through characterization and experimental analysis, including pore filling effect, π-π electron-donor-acceptor (EDA) interaction, hydrogen bonding force, hydrophobic-hydrophobic interaction as well as electrostatic force. In addition, response surface methodology (RSM) revealed the treatment optimization and reciprocal relationship within multi-variables. Furthermore, taking advantage of favorable dispersion and outstanding competitive behavior, SLEL-1 was established as an in-situ adsorptive agent in dynamic saturated columns on a laboratory scale to investigate the removal of LEV from water-bearing stratum. Overall, the findings of this work provided an insight into the fabrication of SLELs as long-term mobile and reusable adsorptive agents for practical in-situ applications in the future.


Assuntos
Levofloxacino , Poluentes Químicos da Água , Levofloxacino/análise , Areia , Porosidade , Polímeros , Adsorção , Poluentes Químicos da Água/química
14.
Bioresour Technol ; 351: 127025, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35307521

RESUMO

This study evaluated the relationship between pyrolysis temperature (300-900 ℃), characteristics of swine manure (SM)-derived biochar (BC), and its adsorption of levofloxacin (LEV). The surface structure and chemistry of SM-derived BCs were characterized using Brunauer-Emmett-Teller analysis, scanning electron microscopy, Fourier-transform infrared spectroscopy, X-ray diffraction, Raman spectroscopy, and X-ray photoelectron spectroscopy. According to the characteristic analysis, the surface area and graphitization degree of SM-derived BC increased as temperature rose. The highest adsorption capacity was achieved by BC-900 (158 mg/g); this level was higher than that achieved in previous studies and comparable to that of commercial activated carbons. Characterization and adsorption experiments indicated that pore-filling, π-π stacking interaction, π-π electron donor-acceptor, H-bonding, and hydrophobic interactions each played a critical role in the adsorption of LEV on SM-derived BC. Collectively, this study confirms the potential utility of SM-derived BC for the removal of antibiotics.


Assuntos
Levofloxacino , Poluentes Químicos da Água , Adsorção , Animais , Carvão Vegetal/química , Cinética , Levofloxacino/análise , Esterco , Espectroscopia de Infravermelho com Transformada de Fourier , Suínos , Poluentes Químicos da Água/química
15.
Artigo em Inglês | MEDLINE | ID: mdl-34801729

RESUMO

Aeromonas hydrophila is an opportunistic bacteria with an overwhelming impact on fish farming industry especially with upraising of drug resistant mutants. This study aimed to evaluate and compare the therapeutic and side effects of levofloxacin (LEV), chitosan-nanoparticles (CNPs), and fructooligosaccharides (FOS) in control of this infection in tilapia. A total of 160 Nile-tilapia divided into 8-groups; G1: negative-control, G2: infected-control, G3: non-infected-(levofloxacin (LEV) 10 mg/kg bwt), G4: non-infected-(chitosan-nanoparticles (CNPs) 1 g/kg ration), G5: non-infected-(fructooligosaccharides (FOS) 20 g/kg ration), G6: infected-LEV, G7: infected-CNPs and G8: infected-FOS for 7 days. MICs were (0.125 µg/ml and 1.25 mg/ml) for LEV and CNPs respectively. No mortalities or significant adverse effects were recorded in non-infected treated-groups while infected were (20%) LEV, (30%) CNPs, (40%) FOS and (70%) G2. Aspartate aminotransferase (AST), alanine aminotransferase (ALT) and alkaline phosphatase (ALP) decreased by LEV and CNPs than FOS while all increased total protein (TP) and albumin than G2. Malondialdehyde (MDA) significantly decreased and superoxide dismutase (SOD) and reduced glutathione (GSH) increased in all infected-treated groups than G2 in various degrees. Urea and creatinine descending order were FOS, LEV then CNPs decreased significantly than G2. LEV musculature residues, using HPLC, decreased gradually till the 5th day; 621.00 ± 0.66, 270.00 ± 0.48 then 64.00 ± 0.40, and 471.00 ± 0.79, 175.00 ± 0.52 ppb then not detected at 1st, 3rd, and 5th days of withdrawal in non-infected and infected groups respectively. Finally, LEV and CNPs were superior as bactericidal, decreasing mortalities and enzyme activities while CNPs and FOS increased performance, non-specific immunity, and antioxidant biomarkers.


Assuntos
Aeromonas hydrophila/efeitos dos fármacos , Antibacterianos/farmacologia , Doenças dos Peixes/tratamento farmacológico , Infecções por Bactérias Gram-Negativas/tratamento farmacológico , Nanopartículas/química , Ração Animal , Animais , Antibacterianos/análise , Antioxidantes/metabolismo , Aquicultura , Quitosana/química , Quitosana/farmacologia , Ciclídeos/crescimento & desenvolvimento , Ciclídeos/microbiologia , Doenças dos Peixes/microbiologia , Doenças dos Peixes/mortalidade , Doenças dos Peixes/patologia , Infecções por Bactérias Gram-Negativas/mortalidade , Infecções por Bactérias Gram-Negativas/patologia , Infecções por Bactérias Gram-Negativas/veterinária , Fatores Imunológicos/química , Fatores Imunológicos/farmacologia , Levofloxacino/análise , Levofloxacino/farmacologia , Testes de Sensibilidade Microbiana , Oligossacarídeos/farmacologia , Prebióticos , Taxa de Sobrevida
16.
Braz. J. Pharm. Sci. (Online) ; 58: e18630, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1364418

RESUMO

Abstract The objective of the present investigation was to design, optimize and characterize the gastro retentive floating levofloxacin tablets and perform in-vivo evaluation using radiographic imaging. The floating tablets were prepared by using polymers i.e hydroxy propyl methyl cellulose (HPMC-K4M) and carbopol-940 individually and in combination by nonaquous granulation method. All the Formulations were evaluated for swelling index (S.I), floating behavior and in-vitro drug release kinetics. The compatibility study of levofloxacin with other polymers was investigated by FTIR, DSC, TGA and XRD. Results from FTIR and DSC revealed no chemical interaction amongst the formulation components. The optimized formulation (F11) showed floating lag time (FLT), total floating time (TFT) swelling index (S.I) of 60 sec, >16h and approximately 75 %, respectively. Moreover, F11 showed zero order levofloxacin release in simulated gastric fluid over the period of 6 h. X-ray studies showed that total buoyancy time was able to delay the gastric emptying of levofloxacin floating tablets in rabbits for more than 4 hours. In conclusion the optimized formulation (F11) can be used for the sustained delivery of levofloxacin for the treatment of peptic ulcer.


Assuntos
Liberação Controlada de Fármacos , Úlcera Péptica/classificação , Comprimidos/farmacologia , Raios X/efeitos adversos , Técnicas In Vitro/instrumentação , Espectroscopia de Infravermelho com Transformada de Fourier , Composição de Medicamentos/instrumentação , Otimização de Processos/análise , Levofloxacino/análise , Esvaziamento Gástrico/efeitos dos fármacos
17.
Bioanalysis ; 13(13): 1063-1070, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34100294

RESUMO

Aim: A new HPLC method with fluorescence detection has been developed and validated for the determination of levofloxacin, one of the fluoroquinolone class antibiotics, in breast milk. Materials & methods: Chromatographic separation was carried out on a reversed phase C18 column with acetonitrile and 10 mM o-phosphoric acid (25:75, v/v) mobile phase composition. Moxifloxacin was used as internal standard and the peaks were detected by fluorescence detection. Results & conclusion: Calibration graph was found linearly within the range of 2.5-500 ng/ml. Limit of detection and limit of quantification were found to be 0.63 and 2.11 ng/ml, respectively. Mean absolute recovery was 96.18%. The developed method has been successfully applied to the determination of levofloxacin in human breast milk taken from two healthy volunteers.


Assuntos
Antibacterianos/análise , Cromatografia Líquida de Alta Pressão/métodos , Fluoroquinolonas/análise , Levofloxacino/análise , Leite Humano/química , Adulto , Calibragem , Feminino , Fluorescência , Humanos , Moxifloxacina/análise , Reprodutibilidade dos Testes
18.
Anal Bioanal Chem ; 413(16): 4329-4339, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34041574

RESUMO

A reliable and efficient method for the simultaneous extraction and determination of antibiotics of ciprofloxacin and levofloxacin from milk was developed with solid phase extraction based on tailored adsorbent materials of deep eutectic solvents modified phenolic resin (DES-R-SPE). Six types of polyhydric alcohol-based hydrophilic DESs were prepared to modify the phenolic resin with the compositions of 3-aminophenol as a functional monomer, glyoxylic acid as a crosslinker, and polyethylene glycol 6000 as a porogen. And the prepared DES-Rs showed better extraction capacities for the target analytes than the unmodified phenolic resin because of more hydrogen bonding and electrostatic interactions supplied by DESs. The choline chloride-glycerol-based resin (DES1-R) with the highest adsorption amounts was selected and the adsorption behavior of it was studied with static adsorption and the dynamic adsorption performance; the adsorption process followed Freundlich isotherm (R2 ≥ 0.9337) and pseudo-second-order (R2 ≥ 0.9951). The present DES1-R-SPE method showed good linear range from 0.5 to100 µg mL-1 (R2 ≥ 0.9998), good recoveries of spiked milk samples (LEV, 96.7%; CIP, 101.5%), and satisfied repeatability for intra-day and inter-day (LEV, RSD≤5.4%; CIP, RSD≤4.6%).


Assuntos
Antibacterianos/isolamento & purificação , Ciprofloxacina/isolamento & purificação , Contaminação de Alimentos/análise , Formaldeído/química , Levofloxacino/isolamento & purificação , Leite/química , Fenóis/química , Polímeros/química , Adsorção , Animais , Antibacterianos/análise , Ciprofloxacina/análise , Interações Hidrofóbicas e Hidrofílicas , Levofloxacino/análise , Extração em Fase Sólida/métodos , Solventes
19.
Inorg Chem ; 60(9): 6585-6599, 2021 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-33878862

RESUMO

Silver vanadate nanorods (ß-AgVO3) with silver nanoparticles (Ag-NPs) decorated on the surface of the rods were synthesized by using simple hydrothermal technique and later anchored onto nitrogen-doped reduced graphene oxide (N-rGO) to make a novel nanocomposite. Experimental analyses were carried out to identify the electronic configuration by X-ray diffraction analysis, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy analysis, which revealed monoclinic patterns of the C12/m1 space group with Wulff construction forming beta silver vanadate (ß-AgVO3) crystals with optical density and phase transformations. Ag nucleation showed consistent results with metallic formation and electronic changes occurring in [AgO5] and [AgO3] clusters. Transmission electron microscopy and field-emission scanning electron microscopy with elemental mapping and EDX analysis of the morphology reveals the nanorod structure for ß-AgVO3 with AgNPs on the surface and sheets for N-rGO. Additionally, a novel electrochemical sensor is constructed by using Ag/AgVO3/N-rGO on screen-printed carbon paste electrodes for the detection of antiviral drug levofloxacin (LEV) which is used as a primary antibiotic in controlling COVID-19. Using differential pulse voltammetry, LEV is determined with a low detection limit of 0.00792 nm for a linear range of 0.09-671 µM with an ultrahigh sensitivity of 152.19 µA µM-1 cm-2. Furthermore, modified electrode performance is tested by real-time monitoring using biological and river samples.


Assuntos
Espectroscopia Dielétrica/instrumentação , Espectroscopia Dielétrica/métodos , Levofloxacino/análise , Nanocompostos/química , Antivirais/análise , Antivirais/sangue , Antivirais/urina , Carbono/química , Eletrodos , Grafite/química , Humanos , Levofloxacino/sangue , Levofloxacino/urina , Limite de Detecção , Nanopartículas Metálicas/química , Microscopia Eletrônica de Transmissão , Nanotubos/química , Espectroscopia Fotoeletrônica , Prata/química , Compostos de Prata/química , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Comprimidos , Vanadatos/química , Difração de Raios X
20.
Anal Chem ; 92(5): 3636-3642, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32011123

RESUMO

We developed a J-compensated QHSQC NMR method for the quantitative measurement of enantiopurity and concentration of levofloxacin in a complex drug matrix. The pulse sequence can achieve uniform signal responses by the suppression of the heteronuclear coupling modulation and alleviation of the homonuclear coupling evolution. Furthermore, we discuss the influence of relaxation on peak intensities and propose the selection conditions of reference signals to achieve accurate quantifications. The evaluation of the methodology shows that the results obtained by selected peaks are in accordance with theoretical analysis with good reliability and linearity. The enantiomeric separation and quantification of levofloxacin in creams are achieved by using a chiral solvating agent, a reference compound, and the J-compensated QHSQC pulse sequence. To our knowledge, this is the first example of QHSQC methodology to quantify enantiomers in the complex matrix.


Assuntos
Levofloxacino/análise , Levofloxacino/química , Espectroscopia de Ressonância Magnética/métodos , Modelos Lineares , Reprodutibilidade dos Testes , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA