Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2219-2226, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38400857

RESUMO

PURPOSE: To evaluate the Schlemm's canal (SC) parameters obtained by swept-source optical coherence tomography (OCT) different in Graves' ophthalmopathy (GO) eyes compared to healthy eyes. METHODS: This cross-sectional observational study evaluated 64 eyes of 32 GO cases and 56 eyes of 28 healthy controls. The study was conducted between October 2020 and June 2021. SC images were obtained from the temporal limbus of individuals using swept-source OCT. SC length (SCL) and SC area (SCA) were measured. The relationship between SC parameters in the patient group and intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness, Graves' disease (GD) duration, and clinical activity score (CAS) was evaluated. RESULTS: In the GO group, 64 eyes of 32 patients were evaluated, and in the age and gender-matched healthy control group, 56 eyes of 28 individuals were assessed. SC images from 4 eyes of 4 patients in the patient group and 1 eye of 1 patient in the control group were not clear, preventing SCL and SCA measurements for these eyes. SCL and SCA measurements were found to be lower, and IOP and Hertel values were higher in the GO group compared to the healthy controls. However, no significant correlation was observed between SCL and SCA with IOP, RNFL thickness, GD duration, GO duration, or CAS in the GO group. In the GO group, the mean value of SCA was found to be higher in eyes with glaucoma or OHT compared to those without. CONCLUSION: These findings indicate that SC in GO-affected eyes is shorter and has a smaller area than in healthy individuals. Additionally, higher IOP and Hertel values were observed in the GO group compared to healthy controls. This study suggests that assessing SC using anterior segment OCT could provide valuable insights into the regulation of IOP and the development of glaucoma in GO-affected eyes.


Assuntos
Oftalmopatia de Graves , Pressão Intraocular , Fibras Nervosas , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Oftalmopatia de Graves/diagnóstico , Estudos Transversais , Masculino , Feminino , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Pessoa de Meia-Idade , Células Ganglionares da Retina/patologia , Adulto , Limbo da Córnea/patologia , Limbo da Córnea/diagnóstico por imagem , Esclera/patologia , Esclera/diagnóstico por imagem , Idoso , Canal de Schlemm
2.
Am J Ophthalmol ; 262: 178-185, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38360335

RESUMO

PURPOSE: To investigate the correlation between the opening and closing states of anterior chamber angle (ACA) and the density of limbal epithelial basal cells (LEBCs) in subjects with primary angle-closure glaucoma (PACG). DESIGN: Cross-sectional observational study. METHODS: A total of 54 eyes of 29 patients diagnosed with PACG were included in the study. Fifty-four eyes from normal subjects were included as control. Automatic evaluation system for ultrasound biomicroscopy images of anterior chamber angle was used to assist ophthalmologists in identifying the opening or closing state of ACA, and the in vivo confocal microscopy (IVCM) was used to evaluate the density of LEBCs in different directions. RESULTS: (1) The average density of LEBCs in the superior, inferior, nasal, and temporal limbus of the eyes in the PACG group was lower than that in the control group, and this pattern did not align with the density distribution observed in the control group. (2) In the early, moderate and advanced PACG, the density of LEBCs corresponding to the closed angle was lower than that in the control group (P < .05). Compared with the density of LEBCs corresponding to the closed angle and the open angle, the closed angle of PACG in the early, moderate and advanced stages was less than that in the open angle (P < .05 in the early and moderate stages; advanced stage P > .05). (3) The basal cell density was processed by dimensionless analysis. In the data calculated by averaging and minimizing, both closed angle dimensionless values were smaller than the open angle (P < .05). (4) Comparative analysis was conducted among the normal, open-angle, and closed-angle conditions in the superior, inferior, nasal, and temporal limbus. In the early stage of PACG, significant differences were observed in 4 limbal regions (P < .05), while in the moderate PACG stage, this difference was noted in 3 limbal regions (P < .05). In advanced PACG, 2 limbal regions exhibited significant differences (P < .05). These findings suggest that during the early PACG stage, angle closure is the predominant influencing factor on LEBCs density, while in the advanced stage, the decrease in density is attributed to a combination of angle closure and the natural progression of the disease. CONCLUSIONS: There is a significant correlation between anterior chamber angle status and LEBCs. Advanced PACG and angle closure should be highly suspected of the occurrence of limbal stem cell deficiency (LSCD).


Assuntos
Câmara Anterior , Glaucoma de Ângulo Fechado , Pressão Intraocular , Limbo da Córnea , Microscopia Acústica , Microscopia Confocal , Células-Tronco , Humanos , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/fisiopatologia , Estudos Transversais , Limbo da Córnea/patologia , Limbo da Córnea/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Contagem de Células , Idoso , Células-Tronco/patologia , Pressão Intraocular/fisiologia , Gonioscopia , Deficiência Límbica de Células-Tronco
3.
Vet Ophthalmol ; 27(1): 30-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37118910

RESUMO

OBJECTIVE: To evaluate alterations in epithelial thickness during corneal degeneration, corneal pigmentation, and additional features observed through spectral-domain optical coherence tomography (SD-OCT) in brachycephalic dogs. ANIMALS AND PROCEDURES: The study used 55 eyes from 49 brachycephalic dogs that underwent OCT-containing ophthalmic examinations. The examined eyes were classified into corneal degeneration, corneal pigmentation, and normal groups according to corneal lesions. For each eye, corneal epithelial thickness (CET) in the central cornea and maximum limbal epithelial thickness (maxLET) in 4 quadrants of limbus (superior, inferior, nasal, and temporal) were measured from OCT images. Additional abnormal findings on OCT images, including irregular epithelium, subepithelial hyperreflectivity, and conjunctivochalasis, were also recorded. RESULTS: The corneal degeneration group had significantly thinner nasal and temporal maxLETs than that of the normal group (p < .001). In the central corneal OCT image of the corneal degeneration group, an irregular epithelium was observed in 70.6% and subepithelial hyperreflectivity in 82.4%, both of which were significantly higher than the normal group (p < .001). In a comparative analysis, the nasal, temporal, and inferior maxLETs were significantly thinner in the corneal pigmentation group than those in the normal group (p < .001, p < .001, and p = .01, respectively). CONCLUSIONS: Morphological changes in the limbal epithelium were observed in dogs with corneal degeneration and corneal pigmentation. LET reduction could be associated with their pathogenesis and would be valuable as an additional parameter for corneal diseases.


Assuntos
Doenças da Córnea , Distrofias Hereditárias da Córnea , Craniossinostoses , Doenças do Cão , Epitélio Corneano , Limbo da Córnea , Cães , Animais , Tomografia de Coerência Óptica/veterinária , Tomografia de Coerência Óptica/métodos , Limbo da Córnea/diagnóstico por imagem , Córnea/patologia , Doenças da Córnea/diagnóstico por imagem , Doenças da Córnea/veterinária , Doenças da Córnea/patologia , Distrofias Hereditárias da Córnea/patologia , Distrofias Hereditárias da Córnea/veterinária , Craniossinostoses/veterinária , Epitélio Corneano/diagnóstico por imagem , Epitélio Corneano/patologia , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/patologia
4.
Cont Lens Anterior Eye ; 46(6): 102065, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37827941

RESUMO

PURPOSE: To present a new method for 3-dimensional external limbal demarcation on corneoscleral topography derived from optical coherence tomography (OCT). Limbal shape is investigated and compared to other landmarks. METHODS: Images from the anterior segment were obtained with a ultrawide-field (20 mm) OCT. An automated algorithm was developed to demarcate the topographic limbus based on the transition from corneal to scleral curvature. The internal limbus was manually identified as the scleral spur on the OCT images. The external topographic limbus was fit with a circle on a plane. Ellipticity and ovality were defined by the lateral limbal deviation from the best-fit circle. Toricity was defined by the axial deviation from the best-fit plane. Repeatability was assessed by the within-subject standard deviation from two repeated measurements. For comparison, the white-to-white (WTW) diameter was obtained from Pentacam HR. RESULTS: 18 eyes from 11 subjects were analyzed. The topographic limbal diameter was 12.16 ± 0.68 mm (mean ± standard deviation) horizontally and 11.18 ± 0.65 mm vertically. The repeatability for the topographic limbal diameter was 0.054 mm. The internal and WTW horizontal limbal diameters were significantly smaller (linear mixed-effects model (GLMM), p <.017). The vertical internal limbal diameter was significantly larger (GLMM p <.05). The topographic limbus had significant ellipticity (0.25 ± 0.13 mm, wider horizontally, repeatability of 0.07 mm) and toricity (0.15 ± 0.08 mm, flatter horizontally, repeatability of 0.10 mm). Low coefficients of determination were found for the topographical limbus with the internal limbus (R2=0.021 and R2=0.039, for horizontal and vertical diameters respectively) and with the WTW (R2=0.146 for the horizontal diameter). CONCLUSION: The proposed method to demarcate the 3D external topographical limbus is repeatable. The topographic limbal shape and size cannot be accurately derived from WTW nor internal limbus measures. This new technology may improve the process of scleral lens fitting.


Assuntos
Limbo da Córnea , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Topografia da Córnea/métodos , Esclera/diagnóstico por imagem , Córnea , Algoritmos , Limbo da Córnea/diagnóstico por imagem
5.
Vet Ophthalmol ; 26 Suppl 1: 89-97, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35904513

RESUMO

OBJECTIVE: To investigate the variance in corneal epithelial thickness (CET) and limbal epithelial thickness (LET) according to the age and skull type by using spectral-domain optical coherence tomography (SD-OCT) in normal dogs. ANIMALS AND PROCEDURES: This study used an eye each from 46 dogs (24 brachycephalic and 22 non-brachycephalic dogs) assessed to have clear corneas. Each dog was classified according to age into groups 1 (0-5 years), 2 (6-10 years), and 3 (>11 years). OCT imaging was performed on the central cornea for CET and perpendicular to the quadrant of the limbus for LET. The average of the maximum LET (maxLET) value was measured in four eye quadrants. RESULTS: Corneal epithelial thickness was not significantly different according to age in brachycephalic and non-brachycephalic dogs. Visualization of the limbal invagination was better when the maxLET was thick. Nasal and temporal maxLETs were significantly thicker than superior and inferior maxLETs in non-brachycephalic dogs. In brachycephalic dogs, there was a significant decrease in nasal maxLET with age (rs  = -0.489, p = .015). Significant differences between brachycephalic and non-brachycephalic dogs were observed in nasal maxLET (p = .024) and temporal maxLET (p = .011). CONCLUSIONS: Invagination was better visualized in the nasal and temporal limbal quadrants of non-brachycephalic dogs compared with brachycephalic dogs, and the maxLETs of the regions were thicker than those of the brachycephalic dogs. CET and LET measurements using SD-OCT can help in clinical assessment and research on ocular surface diseases in dogs.


Assuntos
Doenças da Córnea , Doenças do Cão , Epitélio Corneano , Limbo da Córnea , Cães , Animais , Tomografia de Coerência Óptica/veterinária , Tomografia de Coerência Óptica/métodos , Epitélio Corneano/diagnóstico por imagem , Limbo da Córnea/diagnóstico por imagem , Córnea , Doenças da Córnea/diagnóstico por imagem , Doenças da Córnea/veterinária , Doenças do Cão/diagnóstico por imagem
6.
Sci Rep ; 12(1): 1400, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-35082345

RESUMO

We examined the performance of human Schlemm's canal (SC) imaging using different OCT devices: CIRRUS 5000 (840 nm, spectral-domain (SD)-OCT), PLEX Elite 9000 (1060 nm, swept-source (SS)-OCT) and CASIA SS-1000 (1310 nm, SS-OCT), and analyzed potential impact factors on visualization and the quantitative assessment of SC morphology in a pilot study. Ten healthy subjects were imaged using three OCT devices by a single experienced operator on the same day. Each eye underwent two cubic scans by each device, one on nasal and the other on temporal quadrant. The B-scan showing the largest SC was manually selected for processing. Four quantitative metrics, including one morphological metric as cross-sectional area (CSA), and three performance metrics as contrast, continuity, and coverage, were derived from the datasets. Repeated-measures ANOVA was used to investigate the difference between these parameters from the three devices (P < 0.05). We found the CSA measured from CIRRUS was significantly larger than PLEX, followed by CASIA. The contrast was highest in CIRRUS, followed by PLEX and CASIA. The coverage was also higher in CIRRUS as compared to PLEX and CASIA. No significant difference was seen in the continuity from the three devices. In summary, we showed the measurements from the three devices were not interchangeable.


Assuntos
Limbo da Córnea/diagnóstico por imagem , Esclera/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação , Malha Trabecular/diagnóstico por imagem , Adulto , Feminino , Glaucoma de Ângulo Aberto/diagnóstico por imagem , Glaucoma de Ângulo Aberto/patologia , Voluntários Saudáveis , Humanos , Pressão Intraocular , Limbo da Córnea/anatomia & histologia , Masculino , Projetos Piloto , Esclera/anatomia & histologia , Tomografia de Coerência Óptica/métodos , Malha Trabecular/anatomia & histologia
7.
Sci Rep ; 11(1): 12502, 2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34127762

RESUMO

Spectral-domain optical coherence tomography (SD-OCT) has been used to observe the morphology of the palisades of Vogt (POV) with satisfactory resolutions. In this study, we used SD-OCT to examine the microstructure of the POV in ocular surface disorders with limbal involvement. We detect subclinical limbal pathologies based on five parameters, including (1) decreased epithelial thickness, (2) loss of the sharp stromal tip, (3) loss of the smooth epithelial-stromal interface, (4) dilated stromal vessels, and (5) decreased POV density. Eighteen eyes of 10 patients with advancing wavelike epitheliopathy (AWE) and 15 eyes of 9 patients with phlyctenular keratitis/ocular rosacea were recruited. SD-OCT could detect abnormal changes in the POV in 100% of the lesion sites. In presumed-healthy areas of the diseased eyes diagnosed by slit-lamp biomicroscopy, SD-OCT detected abnormal changes in the POV in 100% of the eyes in both groups. In patients with unilateral disease, abnormal changes in the POV were detected by SD-OCT in 50% and 100% of presumed-healthy eyes diagnosed by slit-lamp biomicroscopy in the AWE group and phlyctenular keratitis/ocular rosacea group, respectively. SD-OCT is powerful in detecting POV changes in ocular surface disorders and can provide useful information that cannot be provided by slit-lamp biomicroscopy.


Assuntos
Ceratite/diagnóstico , Limbo da Córnea/diagnóstico por imagem , Rosácea/diagnóstico , Tomografia de Coerência Óptica/métodos , Adolescente , Adulto , Criança , Estudos Transversais , Epitélio Corneano/diagnóstico por imagem , Epitélio Corneano/patologia , Estudos de Viabilidade , Feminino , Humanos , Ceratite/patologia , Limbo da Córnea/patologia , Masculino , Pessoa de Meia-Idade , Rosácea/patologia , Microscopia com Lâmpada de Fenda , Adulto Jovem
8.
Invest Ophthalmol Vis Sci ; 62(6): 12, 2021 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-33974047

RESUMO

Purpose: The purpose of this study was to investigate the limbal changes in the palisades of Vogt (POV) in patients with herpes simplex keratitis (HSK) and herpes zoster ophthalmicus (HZO) with the application of in vivo confocal microscopy (IVCM). Methods: We enrolled 35 eyes of 35 consecutive patients with HSK and 4 patients with HZO in this observational study. Thirty-five participants were also recruited from a healthy population as the control group. All subjects were examined by IVCM in addition to routine slit-lamp biomicroscopy. The IVCM images of the corneal basal epithelial cells, corneal nerve, and the corneoscleral limbus were acquired and then were analyzed semiquantitatively. Results: The rate of absent and atypical POV was significantly higher in the affected eyes of patients with HSK than in the contralateral eyes and eyes of controls (88.57% vs. 65.71% vs. 17.14%, P < 0.01). In the HZO group, the rate of absent and atypical POV was 100% in the affected eyes and 50% in the contralateral eyes. When compared to the contralateral unaffected eyes and control eyes, the average density of the central basal epithelial cells and the sub-basal nerve plexus density and the total number of nerves in the central area of the affected eyes were significantly lower in the HSK group (1541 ± 704.4 vs. 2510 ± 746.8 vs. 3650 ± 746.1 cells/mm2, P < 0.0001). Spearman's rank correlation showed that the presence of absent and atypical POV had a significant negative correlation with central corneal basal epithelial cells (rs = -0.44979, P < 0.0001), the density of total nerves (rs = -0.49742, P < 0.0001), and the total nerve numbers (rs = -0.48437, P < 0.0001). A significant positive correlation was established between the presence of absent and atypical POV and HSK severity in affected eyes in the superior, inferior, nasal, and temporal quadrants (rs = 0.68940, rs = 0.78715, rs = 0.65591, and rs = 0.75481, respectively, P < 0.0001) and the contralateral eyes (rs = 0.51636, rs = 0.36207, rs = 0.36990, rs = 0.51241, correspondingly, P < 0.0001). Conclusions: Both eyes of patients with unilateral HSK and HZO demonstrated a profound and significant loss of limbal stem cells, which may explain the fact that HSK and HZO are risk factors for limbal stem cell deficiency (LSCD) in both eyes. The loss of LSCs was strongly correlated with the sub-basal nerve plexus and central basal epithelial cell alterations as shown by IVCM.


Assuntos
Infecções Oculares Virais/patologia , Herpes Zoster Oftálmico/patologia , Ceratite Herpética/patologia , Limbo da Córnea/patologia , Células-Tronco/patologia , Adulto , Contagem de Células , Estudos Transversais , Infecções Oculares Virais/diagnóstico por imagem , Feminino , Herpes Zoster Oftálmico/diagnóstico por imagem , Humanos , Ceratite Herpética/diagnóstico por imagem , Limbo da Córnea/diagnóstico por imagem , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Curr Opin Ophthalmol ; 32(3): 275-279, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33653980

RESUMO

PURPOSE OF REVIEW: The aim of this study was to provide a comprehensive summary of in-vivo imaging techniques of the aqueous outflow system and discuss its role in improving our understanding of glaucoma pathogenesis and management. RECENT FINDINGS: Our understanding of the aqueous outflow system is largely derived from ex-vivo studies. Recent innovations in imaging technology and techniques enable in-vivo evaluation of the conventional outflow system in real-time. Optical coherence tomography allows for noninvasive, high-resolution, volumetric imaging of ocular tissues. Dynamic structural changes have been observed at the trabecular meshwork and Schlemm's canal. In parallel, aqueous angiography using injected tracers show a similar dynamism with variable and pulsatile flow signals. SUMMARY: In-vivo imaging enable real-time evaluation of the conventional aqueous outflow pathway. This emerging field shows great promise to expand our understanding of the pathogenesis and treatment of glaucoma.


Assuntos
Humor Aquoso/diagnóstico por imagem , Diagnóstico por Imagem/métodos , Limbo da Córnea/diagnóstico por imagem , Malha Trabecular/diagnóstico por imagem , Angiografia/métodos , Glaucoma/diagnóstico por imagem , Humanos , Tomografia de Coerência Óptica/métodos
10.
Optom Vis Sci ; 98(2): 127-136, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33534377

RESUMO

SIGNIFICANCE: This study evaluates the reliability and validity of an automatic method of the external and internal limbal points identification from anterior segment optical coherence tomography (OCT) images in comparison with manual delineation. PURPOSE: The purpose of this work was to evaluate the repeatability and precision of a previously proposed automatic method of external and internal limbal points identification and to compare them with the manual delineation by experienced clinicians in terms of limbus diameter. METHODS: Optical coherence tomography tomograms obtained for 12 healthy volunteers without a history of eye diseases were analyzed. Fifteen OCT tomograms were captured for each patient. For all the images, the external and internal limbal points were determined using both the automatic and manual methods. The external and internal limbus diameters were used as the comparative parameter between the methods under consideration. The statistical analysis included mean, standard deviation, the Passing-Bablok regression, and the Pearson correlation coefficient. RESULTS: A strong linear dependence between the automatic and manual methods was identified. While compared with the subjective estimates from clinicians, the automatic technique overestimated the external limbus diameter (bias equals 0.21 mm for optometrist and 0.23 mm for ophthalmologist) and slightly underestimated the internal limbus diameter (bias equals 0.13 mm for optometrist and 0.04 mm for ophthalmologist). The automatic method showed significantly better repeatability than the manual method in the case of external limbal points identification and comparably high repeatability for internal limbal points recognition. CONCLUSIONS: Because of high precision and excellent repeatability, the automatic method of limbal points identification may be successfully used for estimation of the dynamic changes in the geometry of the anterior segment of the eye, where the large number of captured OCT images needs to be processed automatically with high precision.


Assuntos
Córnea/diagnóstico por imagem , Diagnóstico por Computador , Limbo da Córnea/diagnóstico por imagem , Esclera/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto , Segmento Anterior do Olho/diagnóstico por imagem , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
11.
J Pediatr Ophthalmol Strabismus ; 58(1): 62-65, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33495800

RESUMO

PURPOSE: To evaluate the accuracy of anterior segment optical coherence tomography (AS-OCT) for locating horizontal extraocular muscle (EOM) insertion after strabismus surgery. METHODS: The distance from the limbus to the postoperative muscle insertion was measured with calipers intraoperatively and by AS-OCT during the postoperative visit of adults undergoing strabismus surgery. Images were collected by masked technicians. Intraclass correlation coefficients (ICC) were used to evaluate the agreement between measurements. RESULTS: Twenty-eight patients were recruited. Measurements were taken from 31 eyes, including 17 lateral and 14 medial rectus muscles. EOM insertion was successfully identified by AS-OCT for 14 (45%) cases. The ICC between intra-operative and AS-OCT measurement was 0.886 when the distance from the limbus to the insertion of EOM was less than 8 mm and 0.001 when the distance from the limbus was between 8 and 10 mm. EOM insertion was undetectable if distance to the limbus was greater than 10 mm. CONCLUSIONS: AS-OCT can accurately identify post-surgical horizontal muscle insertion if the insertion is less than 8 mm from the limbus. [J Pediatr Ophthalmol Strabismus. 2021;58(1):62-65.].


Assuntos
Limbo da Córnea , Estrabismo , Adulto , Segmento Anterior do Olho/diagnóstico por imagem , Humanos , Limbo da Córnea/diagnóstico por imagem , Limbo da Córnea/cirurgia , Músculos Oculomotores/diagnóstico por imagem , Músculos Oculomotores/cirurgia , Estrabismo/diagnóstico por imagem , Estrabismo/cirurgia , Tomografia de Coerência Óptica
12.
Acta Ophthalmol ; 99(6): e943-e948, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33502099

RESUMO

PURPOSE: To analyse the factors influencing the primary patency of clear corneal incisions in femtosecond laser-assisted cataract surgery (FLACS). METHODS: In this prospective single-centre study, the graphical user interfaces of 159 patients undergoing femtosecond laser-assisted cataract surgery were documented by video. Subsequently, the quality of limbus detection along with the incidence of vessels and an arcus lipoides were assessed by a grading system and analysed in relation to the primary patency of the incisions. In particular, the differences between a superior and a temporal main incision were analysed. RESULTS: The designed grading system could be applied in all cases without any problems. Limbus detection was highly inhomogeneous but had no influence on the patency of the incisions (46.3% poor, 18.4% moderate, 35.1% good). The characteristics of the arcus lipoides had little influence on the patency of the main incisions. Pronounced vascular ingrowth caused more tissue bridges but did not reduce the patency of the incisions. Temporal access was generally easier to open than a superior one (97.1% versus 88.9%). CONCLUSION: We showed a patency rate of superior FLACS incisions of over 97% with the Femto LDV Z8 in our study. Temporal main incision is preferable to superior main incision in more difficult situations. The new grading system is suitable for further studies to provide information on the quality of the incision.


Assuntos
Extração de Catarata/métodos , Catarata/diagnóstico , Topografia da Córnea/métodos , Terapia a Laser/métodos , Limbo da Córnea/diagnóstico por imagem , Acuidade Visual , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Ocul Surf ; 19: 94-103, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32335247

RESUMO

PURPOSE: To determine the utility of anterior segment optical coherence tomography angiography (AS-OCTA) in assessing limbal stem cell deficiency (LSCD). METHODS: Twenty-six eyes of 24 LSCD patients, classified clinically into stage I, II and III, and 12 eyes of 12 healthy subjects were included. AS-OCTA images were analyzed by two masked observers, measuring the maximum corneal vascular extension (CoVE) from the limbus to the furthest vessel over the cornea, and corneal vascular thickness (CoVT) from the most superficial to the deepest corneal vessel. RESULTS: CoVE was 0.27 ± 0.10, 0.79 ± 0.21, 1.68 ± 0.89 and 2.53 ± 0.82 mm in controls, stage I, II and III LSCD, respectively (p < 0.001). The CoVT was 51.0 ± 19.4, 113.7 ± 36.6, 129.7 ± 39.3 and 336.0 ± 85.0 µm, respectively (p < 0.001). There was a significant difference in CoVE and CoVT between all stages compared to controls, and between stage I and III LSCD (p < 0.001). Further, CoVE showed a significant difference between stage I and II, whereas CoVT showed a significant difference between stage II and III LSCD (p < 0.001). BCVA showed strong correlation with CoVT (r = 0.765, p < 0.001) and moderate correlation with CoVE (r = 0.547, p = 0.001). AS-OCTA parameters showed excellent intra- and inter-class correlation coefficients (>0.900). CONCLUSION: LSCD demonstrates significant changes in CoVE and CoVT as early as stage I LSCD in comparison to controls. CoVE and CoVT strongly correlate to both disease severity and BCVA. AS-OCTA may provide novel quantitative and non-invasive parameters to assess LSCD.


Assuntos
Doenças da Córnea , Epitélio Corneano , Limbo da Córnea , Angiografia , Doenças da Córnea/diagnóstico por imagem , Humanos , Limbo da Córnea/diagnóstico por imagem , Microscopia Confocal , Células-Tronco , Tomografia de Coerência Óptica
14.
BMJ Case Rep ; 13(12)2020 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-33318273

RESUMO

A 24-year-old young man presented to us with total limbal stem cell deficiency (LSCD) in the right eye 1 year post ocular chemical burn. The patient subsequently underwent limbal biopsy in the healthy contralateral eye and autologous simple limbal epithelial transplantation in the right eye. The patient was followed up with sequential imaging of the cornea with high-resolution anterior segment optical coherence tomography (HR-ASOCT) for 3 years. The serial HR-ASOCT imaging in the operated eye showed regeneration of the epithelium from the limbal transplant over the human amniotic membrane (hAM) with integration of the transplant within the cornea with subepithelial retention of the hAM. Over the long-term follow-up, thinning of the hAM and thickening of the epithelium was noted. At 3 years, the cornea maintained an intact epithelium with no signs of recurrence of LSCD.


Assuntos
Queimaduras Químicas/diagnóstico por imagem , Queimaduras Químicas/cirurgia , Epitélio Corneano/transplante , Queimaduras Oculares/diagnóstico por imagem , Queimaduras Oculares/cirurgia , Limbo da Córnea/diagnóstico por imagem , Limbo da Córnea/cirurgia , Tomografia de Coerência Óptica , Seguimentos , Humanos , Masculino , Transplante Autólogo , Resultado do Tratamento , Adulto Jovem
15.
PLoS One ; 15(12): e0243382, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33362229

RESUMO

PURPOSE: This study aimed to evaluate the shape of the extraocular muscles (EOMs) in normal subjects using the en-face images of anterior segment optical coherence tomography (AS-OCT). The EOM insertion and the direction of the muscle fibers were investigated. SUBJECTS AND METHODS: A total of 97 healthy normal subjects (194 eyes) at Okayama University Hospital (age, 47.1±21.5 years; range, 8-79 years) participated in the study. A series of 256 tomographic images of the rectus EOMs were captured using the C-scan function of the AS-OCT (CASIA2, TOMEY Co., Japan), and the images were converted to en-face images in multi-TIFF format. The anterior chamber angle to EOM insertion distance (AID) and the angle of the muscle fibers from the insertion site (angle of muscles) were measured from the images. The correlations of AID and angle of muscles with age and axial length were investigated and evaluated. RESULTS: AID and angle of muscles were significantly correlated with age or axial length in some EOMs. The AIDs of medial rectus (MR) (P = 0.000) and superior rectus (SR) (P = 0.005) shortened with age. The AIDs of MR (P = 0.001) and inferior rectus (IR) (P = 0.035) elongated with axial length, whereas lateral rectus (LR) (P = 0.013) shortened. The angles of MR (P = 0.001) and LR (P = 0.000) were found to have a more downward direction toward the posterior in older subjects. CONCLUSION: En-face images can be created by AS-OCT, and the shape of the EOMs in normal subjects using these image measurements was available. With the ability to assess the EOMs, AID and angle of muscles are expected give useful information for treating and diagnosing strabismus-related diseases.


Assuntos
Envelhecimento/fisiologia , Segmento Anterior do Olho/diagnóstico por imagem , Músculos Oculomotores/diagnóstico por imagem , Tomografia de Coerência Óptica , Adolescente , Adulto , Idoso , Segmento Anterior do Olho/fisiologia , Criança , Feminino , Humanos , Japão/epidemiologia , Limbo da Córnea/diagnóstico por imagem , Limbo da Córnea/fisiologia , Masculino , Pessoa de Meia-Idade , Músculos Oculomotores/fisiologia , Adulto Jovem
16.
Invest Ophthalmol Vis Sci ; 61(13): 7, 2020 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-33141893

RESUMO

Purpose: Currently, the biomechanical properties of the corneo-scleral limbus when the eye-globe deforms are largely unknown. The purpose of this study is to evaluate changes in elasticity of the cornea, sclera, and limbus when subjected to different intraocular pressures (IOP) using wave-based optical coherence elastography (OCE). Special attention was given to the elasticity changes of the limbal region with respect to the elasticity variations in the neighboring corneal and scleral regions. Methods: Continuous harmonic elastic waves (800 Hz) were mechanically induced in the sclera near the corneo-sclera limbus of in situ porcine eye-globes (n = 8). Wave propagation was imaged using a phase-sensitive optical coherence tomography system (PhS-OCT). The eyes were subjected to five different IOP-levels (10, 15, 20, 30, and 40 mm Hg), and spatially distributed propagation velocities were calculated along corneal, limbal, and scleral regions. Finite element analysis (FEA) of the same regions under the same excitation conditions were conducted for further validation of results. Results: FEA demonstrated that the stiffness of the heterogeneous cornea-limbus-sclera transition can be characterized by phase velocity measurements of the elastic waves produced at 800 Hz in the anterior eye. Experimental results revealed that the wave speed in the limbus (cL = 6.5 m/s) is between the cornea (cc = 2.9 m/s) and sclera (cs = 10.0 m/s) at a physiological IOP level (15 mm Hg) and rapidly increases as the IOP level is increased, even surpassing the wave speed in the sclera. Finally, the change in elastic wave speed in the limbus (ΔcL∼18.5 m/s) was greater than in the cornea (Δcc ∼12.6 m/s) and sclera (Δcs∼8.1 m/s) for the same change in IOP. Conclusions: We demonstrated that wave-based OCE can be utilized to assess limbus biomechanical properties. Moreover, experimental evidence showed that the corneo-scleral limbus is highly nonlinear compared to the cornea and sclera when the eye-globe is deformed by an increase of IOP. This may suggest that the limbus has enough structural flexibility to stabilize anterior eye shape during IOP changes.


Assuntos
Segmento Anterior do Olho/fisiologia , Fenômenos Biomecânicos/fisiologia , Elasticidade/fisiologia , Limbo da Córnea/fisiologia , Animais , Segmento Anterior do Olho/diagnóstico por imagem , Córnea/diagnóstico por imagem , Córnea/fisiologia , Técnicas de Imagem por Elasticidade , Análise de Elementos Finitos , Pressão Intraocular/fisiologia , Limbo da Córnea/diagnóstico por imagem , Modelos Biológicos , Esclera/diagnóstico por imagem , Esclera/fisiologia , Sus scrofa , Tomografia de Coerência Óptica , Tonometria Ocular
19.
Optom Vis Sci ; 97(9): 766-774, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32941338

RESUMO

SIGNIFICANCE: Precise measurement of corneoscleral topography makes a valuable contribution to the understanding of anterior eye anatomy and supports the fitting process of contact lenses. Sagittal height data, determined by newer noninvasive techniques, are particularly useful for initial scleral lens selection. PURPOSE: The purpose of this study was to investigate the agreement and repeatability of Fourier-based profilometry and Scheimpflug imaging, in the measurement of sagittal height and toricity of the corneoscleral region. METHODS: Minimal (Minsag), maximal (Maxsag) sagittal height, toricity (Maxsag - Minsag), and the maximum possible measurement zone diameter of 38 subjects were compared using the Eye Surface Profiler (ESP; Eagle Eye, Houten, the Netherlands) and the corneoscleral profile module of the Pentacam (Oculus, Wetzlar, Germany) at two different sessions. Correlations between the instruments were analyzed using the Pearson coefficient. Differences between sessions and instruments were analyzed using Bland-Altman and paired t tests. RESULTS: For an equal chord length, the measurement with Pentacam was significantly greater for Minsag (344 µm; 95% confidence interval [CI], 322 to 364 µm; P < .001) and significantly greater for Maxsag (280 µm; 95% CI, 256 to 305 µm; P < .001), but significantly smaller for toricity (-63 µm; 95% CI, -95 to -31 µm; P < .001). Maximum possible measurement zone diameter with ESP (16.4 ± 1.3 mm) was significantly greater than with Pentacam (14.8 ± 1.1 mm) (P < .001). Repeated measurements from session 1 and session 2 were not significantly different for Pentacam and ESP (P = .74 and P = .64, respectively). The 95% CIs around differences indicate good repeatability for Pentacam (mean difference, -0.9 µm; 95% CI, -6.7 to 4.8 µm) and ESP (4.6 µm; -22.4 to 31.6). CONCLUSIONS: Although both instruments deliver useful data especially for the fitting of scleral and soft contact lenses, the sagittal height and the toricity measurements cannot be considered as interchangeable.


Assuntos
Topografia da Córnea , Diagnóstico por Imagem , Limbo da Córnea/anatomia & histologia , Adulto , Lentes de Contato , Feminino , Análise de Fourier , Humanos , Limbo da Córnea/diagnóstico por imagem , Masculino , Estudos Prospectivos , Ajuste de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA