Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.346
Filtrar
1.
J Breath Res ; 18(3)2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38701772

RESUMO

The analysis of volatile organic compounds (VOCs) in exhaled air has attracted the interest of the scientific community because it provides the possibility of monitoring physiological and metabolic processes and non-invasive diagnostics of various diseases. However, this method remains underused in clinical practice as well as in research because of the lack of standardized procedures for the collection, storage and transport of breath samples, which would guarantee good reproducibility and comparability of results. The method of sampling, as well as the storage time of the breath samples in the polymer bags used for sample storage and transport, affect the composition and concentration of VOCs present in the breath samples. The aim of our study was to compare breath samples obtained using two methods with fully disposable equipment: a Haldane sampling tube intended for direct breath collection and breath samples exhaled into a transparent Tedlar bag. The second task was to monitor the stability of selected compounds of real breath samples stored in a Tedlar bag for 6 h. Gas chromatography coupled with ion mobility spectrometry (GC-IMS) implemented in the BreathSpec®device was used to analyse exhaled breath. Our results showed a significant difference in the signal intensity of some volatiles when taking a breath sample with a Haldane tube and a Tedlar bag. Due to its endogenous origin, acetone levels were significantly higher when the Haldane tube sampler was used while elevated levels of 2-propanol and unidentified VOC (designated as VOC 3) in the Tedlar bag samples likely originated from contamination of the Tedlar bags. The VOC stability study revealed compound-specific signal intensity changes of the selected VOCs with storage time in the Tedlar bags, with some volatiles showing increasing signal intensity during storage in Tedlar bags. This limits the use of Tedlar bags only for very limited time and carefully selected purpose. Our results highlight the importance of careful design and implementation of experiments and clinical protocols to obtain relevant and reliable results.


Assuntos
Testes Respiratórios , Manejo de Espécimes , Compostos Orgânicos Voláteis , Humanos , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Compostos Orgânicos Voláteis/análise , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Mobilidade Iônica/instrumentação , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Expiração , Pessoa de Meia-Idade , Fatores de Tempo
2.
Forensic Sci Int ; 358: 112010, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38581825

RESUMO

We used a nanopore sequencer to quantify DNA fragments > 10,000 bp in size and then evaluated their relationship with short-term bloodstain age. Moreover, DNA degradation was investigated after bloodstains were wetted once with water. Bloodstain samples on cotton gauze were stored at room temperature and low humidity for up to 6 months. Bloodstains stored for 1 day were wetted with nuclease-free water, allowed to dry, and stored at room temperature and low humidity for up to 1 week. The proportion of fragments > 20,000 bp in dry bloodstains tended to decrease over time, particularly for fragments > 50,000 bp in size. This trend was modeled using a power approximation curve, with the highest R2 value (0.6475) noted for fragments > 50,000 bp in size; lower values were recorded for shorter fragments. The proportion of longer fragments was significantly reduced in bloodstains that were dried after being wetted once, and there was significant difference in fragments > 50,000 bp between dry conditions and once-wetted. This result suggests that even temporary exposure to water causes significant DNA fragmentation, but not extensive degradation. Thus, bloodstains that appear fresh but have a low proportion of long DNA fragments may have been wetted previously. Our results indicate that evaluating the proportion of long DNA fragments yields information on both bloodstain age and the environment in which they were stored.


Assuntos
Manchas de Sangue , DNA , Nanoporos , Manejo de Espécimes , Humanos , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Análise de Sequência de DNA , Degradação Necrótica do DNA , Fatores de Tempo , Fragmentação do DNA , Impressões Digitais de DNA/instrumentação , Impressões Digitais de DNA/métodos
3.
Am J Vet Res ; 85(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38479103

RESUMO

OBJECTIVE: To identify the safest, most efficient method for hair sample collection from companion dogs among clippers, scissors, and razors and to validate obtained samples with cortisol concentration analysis. ANIMALS: 25 healthy, privately owned dogs. METHODS: 2 hair samples were collected from each dog's ischiatic region with different implements (scissors, razors, or clippers). The collecting clinician completed a Hair Collection Questionnaire (HCQ) for each sample that compared subjective sample quality, time of collection, restraint needed, and patient experience. Each sample was evaluated by cortisol enzyme immunoassay. RESULTS: Clippers had higher overall HCQ scores than scissors, and scissors had higher HCQ scores than razors. Collection was faster for clippers than scissors, and scissors were faster than razors. There were no differences in sample quality between scissors and clippers, and sample quality was lower with razors. There was no difference in restraint needed or patient experience. Collection of long hair had higher HCQ scores than collection of medium and short hair. Collection of hair from dogs with an undercoat had higher HCQ scores than collection of hair from dogs without an undercoat. Dog size had no effect on HCQ score. Hair cortisol concentration did not vary between scissors or clippers (P = .111). Hair color and age did not affect hair cortisol concentration (P = .966 and P = .676, respectively). CLINICAL RELEVANCE: Clippers are recommended for hair sample collection from companion dogs. Scissors are an adequate alternative.


Assuntos
Cabelo , Hidrocortisona , Cães , Animais , Cabelo/química , Hidrocortisona/análise , Masculino , Feminino , Manejo de Espécimes/veterinária , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , Envelhecimento , Inquéritos e Questionários
4.
J Forensic Sci ; 69(3): 1002-1010, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38380584

RESUMO

Plastic bags, such as ziplock bags, have been used to transport illicit materials worldwide; however, very few studies have tried to optimize the recovery of DNA from these items. This study reports on the best combination of swabs and moistening solution for the greatest recovery of cellular material from ziplock bags. Five swabs, two different variations of Copan Diagnostics nylon 4N6FLOQSwabs, one Medical Wire rayon DRYSWAB, one IsoHelix rayon swab, and one Livingstone cotton swab, were evaluated with two moistening solutions, Triton X-100 in either distilled water or isopropanol. Fingermarks were deposited on ziplock bags and stained with Diamond™ Nucleic Acid Dye to allow visualization of the cells pre- and post-swabbing to determine the number of cells recovered. Based on cell counting data, swabs moistened with Triton X-100 in distilled water performed better than those moistened with isopropanol. Livingstone cotton swabs had the worst recovery of cellular material, while the other swabs tested had no significant difference in their respective solutions. A comparison of the best three swabs for cellular recovery yielded no differences in the DNA concentration extracted. A linear relationship was observed between the log number of cells recovered by swabbing and the DNA concentration following extraction and quantification. The process of monitoring cell collection using fluorescence microscopy on ziplock bags allowed evaluation of swabbing efficacy. Additionally, this study highlights the ability to evaluate cellular recovery independently of traditional extraction, quantification, or profiling techniques which may unequally affect samples.


Assuntos
2-Propanol , DNA , Microscopia de Fluorescência , Octoxinol , Manejo de Espécimes , Humanos , Manejo de Espécimes/métodos , Manejo de Espécimes/instrumentação , DNA/isolamento & purificação , DNA/análise , Dermatoglifia , Impressões Digitais de DNA , Contagem de Células
7.
BMC Pregnancy Childbirth ; 22(1): 194, 2022 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-35264142

RESUMO

BACKGROUND: Sexually transmitted infections (STIs) during pregnancy may increase the risk of adverse pregnancy outcomes. STI syndromic management is standard of care in South Africa but has its limitations. We evaluated the impact of diagnosing and treating curable STIs during pregnancy on adverse pregnancy and birth outcomes. METHODS: We combined data from two prospective studies of pregnant women attending public sector antenatal care (ANC) clinics in Tshwane District and Cape Town, South Africa. Pregnant women were enrolled, tested and treated for STIs. We evaluated the association between any STI at the first ANC visit and a composite adverse pregnancy outcome (miscarriage, stillbirth, preterm birth, early neonatal death, or low birthweight) using modified Poisson regression models, stratifying by HIV infection and adjusting for maternal characteristics. RESULTS: Among 619 women, 61% (n = 380) were from Tshwane District and 39% (n = 239) from Cape Town; 79% (n = 486) were women living with HIV. The prevalence of any STI was 37% (n = 228); C. trachomatis, 26% (n = 158), T. vaginalis, 18% (n = 120) and N. gonorrhoeae, 6% (n = 40). There were 93% (n = 574) singleton live births, 5% (n = 29) miscarriages and 2% (n = 16) stillbirths. Among the live births, there were 1% (n = 3) neonatal deaths, 7% (n = 35) low birthweight in full-term babies and 10% (n = 62) preterm delivery. There were 24% (n = 146) for the composite adverse pregnancy outcome. Overall, any STI diagnosis and treatment at first ANC visit was not associated with adverse outcomes in women living with HIV (adjusted relative risk (aRR); 1.43, 95% CI: 0.95-2.16) or women without HIV (aRR; 2.11, 95% CI: 0.89-5.01). However, C. trachomatis (aRR; 1.57, 95% CI: 1.04-2.39) and N. gonorrhoeae (aRR; 1.69, 95% CI: 1.09-3.08), were each independently associated with the composite adverse outcome in women living with HIV. CONCLUSION: Treated STIs at the first ANC visit were not associated with adverse pregnancy outcome overall. In women living with HIV, C. trachomatis or N. gonorrhoeae at first ANC were each independently associated with adverse pregnancy outcome. Our results highlights complex interactions between the timing of STI detection and treatment, HIV infection and pregnancy outcomes, which warrants further investigation.


Assuntos
Infecções por HIV/complicações , Programas de Rastreamento/métodos , Complicações Infecciosas na Gravidez/diagnóstico , Resultado da Gravidez/epidemiologia , Infecções Sexualmente Transmissíveis/diagnóstico , Adulto , Chlamydia trachomatis/isolamento & purificação , Centros Comunitários de Saúde , Feminino , Humanos , Neisseria gonorrhoeae/isolamento & purificação , Gravidez , Cuidado Pré-Natal , Prevalência , Estudos Prospectivos , África do Sul/epidemiologia , Manejo de Espécimes/instrumentação , Trichomonas vaginalis/isolamento & purificação
8.
J Pediatr ; 245: 179-183.e8, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35248569

RESUMO

OBJECTIVE: To evaluate the suitability of urine samples collected with cotton balls placed into diapers for routine laboratory chemistry analyses. STUDY DESIGN: Twenty pools of residual unpreserved urine samples were separated into control and treated aliquots. The treated samples were absorbed into 2 different brands of cotton balls, wrapped in 3 different brands of diapers, and incubated at 37°C for 1 hour. The urine-soaked cotton balls were placed into a syringe and expressed via plunger depression. Urine sodium, potassium, creatinine, urea, calcium, magnesium, inorganic phosphorus, albumin, and total protein were measured on all samples on 5 automated clinical chemistry platforms: Ortho Vitros 4600, Siemens Dimension Vista 500, Beckman Coulter AU5822, Roche Cobas 6000, and Abbott Architect c8000 at 5 separate hospital laboratories. Criteria used to exclude the presence of significant effects of urine from presoaked cotton balls in a diaper on the measurement of chemistry laboratory tests were R2 >0.95, slope of 0.9-1.1, and mean bias within ±10%. RESULTS: Albumin and total protein measurements demonstrated significant negative bias in urine from both brands of presoaked cotton balls with all brands of diapers on all 5 chemistry platforms compared with the control urine. We did not observe a significant effect of presoaking urine in cotton balls in a diaper on the measurement of sodium, inorganic phosphorus, and urea. The remaining tests demonstrated significant effects when measured in urine from presoaked cotton balls and/or diapers that were specific to the chemistry analyzer platform or diaper. CONCLUSIONS: Diaper and cotton ball-based urine collection significantly impacts the measurement of several common chemistry assays.


Assuntos
Fibra de Algodão , Manejo de Espécimes , Urinálise , Albuminas , Fraldas Infantis , Humanos , Fósforo , Sódio , Manejo de Espécimes/instrumentação , Ureia , Urinálise/métodos
9.
Sci Rep ; 12(1): 3951, 2022 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-35273232

RESUMO

The SARS-CoV-2 pandemic has brought to light the need for expedient diagnostic testing. Cost and availability of large-scale testing capacity has led to a lag in turnaround time and hindered contact tracing efforts, resulting in a further spread of SARS-CoV-2. To increase the speed and frequency of testing, we developed a cost-effective single-tube approach for collection, denaturation, and analysis of clinical samples. The approach utilizes 1 µL microbiological inoculation loops to collect saliva, sodium dodecyl sulfate (SDS) to inactivate and release viral genomic RNA, and a diagnostic reaction mix containing polysorbate 80 (Tween 80). In the same tube, the SDS-denatured clinical samples are introduced to the mixtures containing all components for nucleic acids detection and Tween 80 micelles to absorb the SDS and allow enzymatic reactions to proceed, obviating the need for further handling of the samples. The samples can be collected by the tested individuals, further decreasing the need for trained personnel to administer the test. We validated this single-tube sample-to-assay method with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) and reverse transcription loop-mediated isothermal amplification (RT-LAMP) and discovered little-to-no difference between Tween- and SDS-containing reaction mixtures, compared to control reactions. This approach reduces the logistical burden of traditional large-scale testing and provides a method of deployable point-of-care diagnostics to increase testing frequency.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , SARS-CoV-2/genética , Saliva/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Humanos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Reação em Cadeia da Polimerase em Tempo Real , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos
10.
Elife ; 112022 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-35060902

RESUMO

Cryogenic electron microscopy has become an essential tool for structure determination of biological macromolecules. In practice, the difficulty to reliably prepare samples with uniform ice thickness still represents a barrier for routine high-resolution imaging and limits the current throughput of the technique. We show that a nanofluidic sample support with well-defined geometry can be used to prepare cryo-EM specimens with reproducible ice thickness from picoliter sample volumes. The sample solution is contained in electron-transparent nanochannels that provide uniform thickness gradients without further optimisation and eliminate the potentially destructive air-water interface. We demonstrate the possibility to perform high-resolution structure determination with three standard protein specimens. Nanofabricated sample supports bear potential to automate the cryo-EM workflow, and to explore new frontiers for cryo-EM applications such as time-resolved imaging and high-throughput screening.


Assuntos
Microscopia Crioeletrônica/métodos , Microfluídica/instrumentação , Microfluídica/métodos , Análise Serial de Proteínas/métodos , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Microscopia Crioeletrônica/instrumentação , Complexo de Endopeptidases do Proteassoma , Água/química
11.
J Mater Sci Mater Med ; 33(1): 8, 2022 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-34982267

RESUMO

The collection capacity of common nasopharyngeal swabs and irregularities of medical personnel limit the accuracy of PCR testing. This study describes a newly designed 3D-printed swab that is combined with a 3D-printed cover to prevent the extraction of undesired nasal secretions. This swab improved the accuracy of PCR test results. The results of a series of experiments showed that, because of the mucus extraction effect, 3D-printed swabs can replace ordinary cotton swabs. The crisis of the worldwide medical supply shortage can be ameliorated to a certain extent by applying 3D printing technology.


Assuntos
Teste de Ácido Nucleico para COVID-19/instrumentação , Manejo de Espécimes/instrumentação , Materiais Biocompatíveis , Fenômenos Biomecânicos , COVID-19/diagnóstico , COVID-19/virologia , Simulação por Computador , Desenho de Equipamento , Análise de Elementos Finitos , Humanos , Teste de Materiais , Nasofaringe/virologia , Impressão Tridimensional , Resinas Sintéticas , Segurança , Resistência à Tração , Têxteis
12.
Microbiol Spectr ; 9(3): e0110821, 2021 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-34878310

RESUMO

Equitable and timely access to COVID-19-related care has emerged as a major challenge, especially in developing and low-income countries. In India, ∼65% of the population lives in villages where infrastructural constraints limit the access to molecular diagnostics of COVID-19 infection. Especially, the requirement of a cold chain transport for sustained sample integrity and associated biosafety challenges pose major bottlenecks to the equitable access. Here, we developed an innovative clinical specimen collection medium, named SupraSens microbial transport medium (SSTM). SSTM allowed a cold chain-independent transport at a wide temperature range (15°C to 40°C) and directly inactivated SARS-CoV-2 (<15 min). Evaluation of SSTM compared to commercial viral transport medium (VTM) in field studies (n = 181 patients) highlighted that, for the samples from same patients, SSTM could capture more symptomatic (∼26.67%, 4/15) and asymptomatic (52.63%, 10/19) COVID-19 patients. Compared to VTM, SSTM yielded significantly lower quantitative PCR (qPCR) threshold cycle (Ct) values (mean ΔCt > -3.50), thereby improving diagnostic sensitivity of SSTM (18.79% [34/181]) versus that of VTM (11.05% [20/181]). Overall, SSTM had detection of COVID-19 patients 70% higher than that of VTM. Since the logistical and infrastructural constraints are not unique to India, our study highlights the invaluable global utility of SSTM as a key to accurately identify those infected and control COVID-19 transmission. Taken together, our data provide a strong justification to the adoption of SSTM for sample collection and transport during the pandemic. IMPORTANCE Approximately forty-four percent of the global population lives in villages, including 59% in Africa (https://unhabitat.org/World%20Cities%20Report%202020). The fast-evolving nature of SARS-CoV-2 and its extremely contagious nature warrant early and accurate COVID-19 diagnostics across rural and urban population as a key to prevent viral transmission. Unfortunately, lack of adequate infrastructure, including the availability of biosafety-compliant facilities and an end-to-end cold chain availability for COVID-19 molecular diagnosis, limits the accessibility of testing in these countries. Here, we fulfill this urgent unmet need by developing a sample collection and transport medium, SSTM, that does not require cold chain, neutralizes the virus quickly, and maintains the sample integrity at broad temperature range without compromising sensitivity. Further, we observed that use of SSTM in field studies during pandemic improved the diagnostic sensitivity, thereby establishing the feasibility of molecular testing even in the infrastructural constraints of remote, hilly, or rural communities in India and elsewhere.


Assuntos
COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , COVID-19/virologia , Teste para COVID-19 , Contenção de Riscos Biológicos , Meios de Cultura/química , Meios de Cultura/metabolismo , Humanos , Técnicas de Diagnóstico Molecular , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/genética , SARS-CoV-2/metabolismo , Manejo de Espécimes/instrumentação
13.
Microbiologyopen ; 10(6): e1244, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34964289

RESUMO

The human microbiome has begun to emerge as a potential forensic tool, with varied applications ranging from unique identification to investigative leads that link individuals and/or locations. The relative abundance of the combined DNA of the microbiome, compared to human nuclear DNA, may expand potential sources of biological evidence, especially in cases with transfer or low-copy number DNA samples. This work sought to determine the optimal swab type for the collection and analysis of microorganisms. A bacterium (Proteus mirabilis) was deposited by pipette onto four swab types (cotton, flocked, dental applicators, and dissolvable), and extraction and real-time PCR quantitation of the bacterial DNA were performed, which allowed for absolute microbial DNA recovery and comparison of yields across the four sampling substrates. Flocked swabs had the highest yield (~1240 ng) compared to the cotton swabs (~184 ng), dental applicators (~533 ng), and dissolvable swabs (~430 ng). The collection efficiency was further evaluated for cotton and flocked swabs using dried microbial samples spotted onto non-porous surfaces (treated wood, glass, plastic, and tile). Flocked swabs performed consistently better across wood, glass, and tile, but showed decreased recovery from plastic. The cotton swabs failed in the recovery of P. mirabilis DNA across all surfaces. Knowing the appropriate sampling substrate will be useful as others continue to investigate the use of the microbiome as a forensics tool.


Assuntos
Técnicas Bacteriológicas/instrumentação , DNA Bacteriano/análise , Microbiota , Proteus mirabilis/isolamento & purificação , Manejo de Espécimes/instrumentação , DNA Bacteriano/isolamento & purificação , Humanos , Proteus mirabilis/genética , Reação em Cadeia da Polimerase em Tempo Real
14.
PLoS Negl Trop Dis ; 15(12): e0009891, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34882672

RESUMO

The direct fluorescent antibody test (dFAT) using brain sample after opening the skull is the standard rabies diagnostic test in animal rabies. However, it is not feasible in many resource-limited settings. Lateral flow devices (LFD) combined with a simple sampling methodology is quicker, simpler, and less hazardous than the standard test and can be a useful tool. We conducted a prospective on-site study to evaluate the diagnostic accuracy of the LFD with the straw sampling method compared with that of the dFAT with the skull opening procedure for post-mortem canine rabies diagnosis. We collected 97 rabies-suspected animals between December 1, 2020 and March 31, 2021. Among the 97 samples, 53 and 50 cases were positive tests for dFAT and LFD, respectively. The sensitivity and specificity of LFD with straw sampling method were 94.3% (95% confidence interval [CI], 84.3-98.8%) and 100% (95% CI, 92.0-100%), respectively. The performance of LFD by the straw sampling method showed relatively high sensitivity and 100% specificity compared with that of dFAT performed on samples collected after opening the skull. This methodology can be beneficial and is a strong tool to overcome limited animal surveillance in remote areas. However, because of our limited sample size, more data using fresh samples on-site and the optimizations are urgently needed for the further implementation in endemic areas.


Assuntos
Encéfalo/virologia , Testes Diagnósticos de Rotina/veterinária , Raiva/diagnóstico , Raiva/veterinária , Manejo de Espécimes/instrumentação , Animais , Autopsia/instrumentação , Autopsia/métodos , Cromatografia de Afinidade/instrumentação , Cromatografia de Afinidade/métodos , Testes Diagnósticos de Rotina/instrumentação , Testes Diagnósticos de Rotina/métodos , Cães , Feminino , Testes Imunológicos/métodos , Masculino , Estudos Prospectivos , Raiva/virologia , Vírus da Raiva/imunologia , Sensibilidade e Especificidade
15.
BMC Microbiol ; 21(1): 324, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809575

RESUMO

BACKGROUND: To initiate fecal and oral collections in prospective cohort studies for microbial analyses, it is essential to understand how field conditions and geographic differences may impact microbial communities. This study aimed to investigate the impact of fecal and oral sample collection methods and room temperature storage on collection samples for studies of the human microbiota. RESULTS: We collected fecal and oral samples from participants in two Iranian cohorts located in rural Yazd (n = 46) and urban Gonbad (n = 38) and investigated room temperature stability over 4 days of fecal (RNAlater and fecal occult blood test [FOBT] cards) and comparability of fecal and oral (OMNIgene ORAL kits and Scope mouthwash) collection methods. We calculated interclass correlation coefficients (ICCs) based on 3 alpha and 4 beta diversity metrics and the relative abundance of 3 phyla. After 4 days at room temperature, fecal stability ICCs and ICCs for Scope mouthwash were generally high for all microbial metrics. Similarly, the fecal comparability ICCs for RNAlater and FOBT cards were high, ranging from 0.63 (95% CI: 0.46, 0.75) for the relative abundance of Firmicutes to 0.93 (95% CI: 0.89, 0.96) for unweighted Unifrac. Comparability ICCs for OMNIgene ORAL and Scope mouthwash were lower than fecal ICCs, ranging from 0.55 (95% CI: 0.36, 0.70) for the Shannon index to 0.79 (95% CI: 0.69, 0.86) for Bray-Curtis. Overall, RNAlater, FOBT cards and Scope mouthwash were stable up to 4 days at room temperature. Samples collected using FOBT cards were generally comparable to RNAlater while the OMNIgene ORAL were less similar to Scope mouthwash. CONCLUSIONS: As microbiome measures for feces samples collected using RNAlater, FOBT cards and oral samples collected using Scope mouthwash were stable over four days at room temperature, these would be most appropriate for microbial analyses in these populations. However, one collection method should be consistently since each method may induce some differences.


Assuntos
Bactérias/isolamento & purificação , Fezes/microbiologia , Microbiota , Boca/microbiologia , Manejo de Espécimes/métodos , Adulto , Bactérias/classificação , Bactérias/genética , Cetilpiridínio , DNA Bacteriano/genética , Combinação de Medicamentos , Feminino , Humanos , Irã (Geográfico) , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos de Amônio Quaternário , RNA Ribossômico 16S/genética , Manejo de Espécimes/instrumentação
16.
J Am Soc Mass Spectrom ; 32(12): 2803-2811, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34739241

RESUMO

Sweat analysis provides an alternative and noninvasive way of clinical diagnostics. However, sampling and transferring sweat-derived samples to analytical instruments is challenging. In this report, we demonstrate a method utilizing a flat disc-shaped sampling probe, and a compatible re-extraction apparatus coupled online with extractive electrospray ionization (EESI) mass spectrometry (MS). The probe enables sampling of metabolites from a skin area of ∼2.2 cm2. The subsequent online re-extraction and analysis by EESI-MS further mitigates matrix effects caused by sweat components, thus eliminating sample preparation steps. The total analysis time is only 6 min. We have optimized the key parameters of the system, including flow rate of the nebulizing gas in ESI, pressure of the nebulizing gas in pneumatic sample nebulizer, flow rate of the solvent in ESI, and composition of extractant. The standard solutions (0.1 mL) were supplemented with 0.04 M sodium chloride to mimic the matrix effect normally observed in sweat samples. The method has been characterized with four chemical standards (positive-ion mode of histidine, leucine, urocanic acid; negative-ion mode of lactic acid). The limits of detection range from 1.09 to 95.9 nmol. We have further demonstrated the suitability of the method for analysis of sweat. An attempt was made to identify some of the recorded signals by product-ion scan and accurate/exact mass matching.


Assuntos
Pele/química , Manejo de Espécimes/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Suor/química , Biomarcadores/análise , Biomarcadores/metabolismo , Desenho de Equipamento , Feminino , Humanos , Limite de Detecção , Masculino
17.
Microbiol Spectr ; 9(2): e0138721, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34612701

RESUMO

Storage of biological specimens is crucial in the life and medical sciences. Storage conditions for samples can be different for a number of reasons, and it is unclear what effect this can have on the inferred microbiome composition in metagenomics analyses. Here, we assess the effect of common storage temperatures (deep freezer, -80°C; freezer, -20°C; refrigerator, 5°C; room temperature, 22°C) and storage times (immediate sample processing, 0 h; next day, 16 h; over weekend, 64 h; longer term, 4, 8, and 12 months) as well as repeated sample freezing and thawing (2 to 4 freeze-thaw cycles). We examined two different pig feces and sewage samples, unspiked and spiked with a mock community, in triplicate, respectively, amounting to a total of 438 samples (777 Gbp; 5.1 billion reads). Storage conditions had a significant and systematic effect on the taxonomic and functional composition of microbiomes. Distinct microbial taxa and antimicrobial resistance classes were, in some situations, similarly affected across samples, while others were not, suggesting an impact of individual inherent sample characteristics. With an increasing number of freeze-thaw cycles, an increasing abundance of Firmicutes, Actinobacteria, and eukaryotic microorganisms was observed. We provide recommendations for sample storage and strongly suggest including more detailed information in the metadata together with the DNA sequencing data in public repositories to better facilitate meta-analyses and reproducibility of findings. IMPORTANCE Previous research has reported effects of DNA isolation, library preparation, and sequencing technology on metagenomics-based microbiome composition; however, the effect of biospecimen storage conditions has not been thoroughly assessed. We examined the effect of common sample storage conditions on metagenomics-based microbiome composition and found significant and, in part, systematic effects. Repeated freeze-thaw cycles could be used to improve the detection of microorganisms with more rigid cell walls, including parasites. We provide a data set that could also be used for benchmarking algorithms to identify and correct for unwanted batch effects. Overall, the findings suggest that all samples of a microbiome study should be stored in the same way. Furthermore, there is a need to mandate more detailed information about sample storage and processing be published together with DNA sequencing data at the International Nucleotide Sequence Database Collaboration (ENA/EBI, NCBI, DDBJ) or other repositories.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Microbiota , Preservação Biológica/métodos , Manejo de Espécimes/métodos , Animais , Bactérias/classificação , Bactérias/genética , Bactérias/isolamento & purificação , Farmacorresistência Bacteriana , Fezes/química , Fezes/microbiologia , Humanos , Preservação Biológica/instrumentação , Esgotos/química , Esgotos/microbiologia , Manejo de Espécimes/instrumentação , Suínos , Temperatura , Fatores de Tempo
18.
Microbiol Spectr ; 9(2): e0073621, 2021 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-34668741

RESUMO

The supply of testing equipment is vital in controlling the spread of SARS-CoV-2. We compared the diagnostic efficacy and tolerability of molded plastic (FinSwab; Valukumpu, Finland) versus flocked nylon (FLOQSwab; Copan, Italy) nasopharyngeal swabs in a clinical setting. Adults (n = 112) with suspected symptomatic COVID-19 infection underwent nasopharyngeal sampling with FinSwab and FLOQSwab from the same nostril at a drive-in coronavirus testing station. In a subset of 36 patients the samples were collected in a randomized order to evaluate the discomfort associated with sampling. SARS-CoV-2 and 16 other respiratory viruses, as well as human ß-actin mRNA were analyzed by using reverse transcriptase PCR (RT-PCR) assays. Among the 112 patients (mean age, 38 [standard deviation (SD), 14] years) ß-actin mRNA was found in all samples. There was no difference in the ß-actin mRNA cycle threshold (CT) values between FinSwab (mean, 22.3; SD, 3.61) and FLOQSwab (mean, 22.1; SD, 3.50; P = 0.46) swabs. There were 31 virus-positive cases (26 rhinovirus, 4 SARS-CoV-2, and 1 coronavirus-OC43), 24 of which were positive in both swabs; 3 rhinovirus positives were only found in the FinSwab, and similarly 4 rhinovirus positives were only found in the FLOQSwab. Rhinovirus CT values were similar between swab types. Of the 36 patients, 22 (61%) tolerated the sampling with the FinSwab better than with the FLOQSwab (P = 0.065). The molded plastic nasopharyngeal swab (FinSwab) was comparable to the standard flocked swab in terms of efficacy for respiratory virus detection and tolerability of sampling. IMPORTANCE We demonstrate that a molded plastic swab is a valid alternative to conventional brush-like swabs in collection of a nasopharyngeal sample for virus diagnostics.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virologia , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/instrumentação , Actinas/genética , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Plásticos , RNA Mensageiro/genética , Infecções Respiratórias/diagnóstico , Rhinovirus/isolamento & purificação , Manejo de Espécimes/métodos , Adulto Jovem
19.
Nat Commun ; 12(1): 6246, 2021 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-34716329

RESUMO

Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.


Assuntos
Proteômica/instrumentação , Proteômica/métodos , Análise de Célula Única/instrumentação , Análise de Célula Única/métodos , Animais , Biomarcadores/análise , Linhagem Celular , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Camundongos , Nanoestruturas/química , Proteínas/análise , Células RAW 264.7 , Reprodutibilidade dos Testes , Análise de Sequência de RNA , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Espectrometria de Massas em Tandem/métodos , Fluxo de Trabalho
20.
Parasit Vectors ; 14(1): 449, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34488835

RESUMO

BACKGROUND: For over a decade, monitoring of West Nile virus (WNV) in Germany has consisted of a bird monitoring programme as well as a mosquito-based surveillance programme employing CO2-baited encephalitis vector surveillance (EVS) traps for mass trapping and screening of mosquitoes. In contrast to the EVS traps, the Reiter/Cummings type box gravid trap collects gravid female mosquitoes, which have already taken a blood meal, increasing the likelihood of being infected with pathogens. The traps can be equipped with a honey-baited Flinders Technology Associates® (FTA) card to encourage sugar feeding by the trapped mosquitoes. FTA cards contain nucleic acid preserving substances, which prevent the degradation of viral RNA in the expectorated mosquito saliva and allows for testing the card for flavivirus RNA. This study aimed to assess the suitability of the method for WNV surveillance in Germany as an alternative to previous methods, which are expensive, time-consuming, and predominantly target host-seeking populations less likely to be infected with WNV. METHODS: In the Thüringer Zoopark Erfurt, snowy owls (Nyctea scandiaca) and greater flamingos (Phoenicopterus roseus) died of WNV infections in July and August 2020. In response, five Reiter/Cummings type box gravid traps were positioned during the daytime on the 10th, 13th, and 16th of September in five different locations. The FTA cards and mosquitoes in the chamber were collected, kept in a cool chain, and further processed for virus detection using a modified generic flavivirus reverse transcription PCR. RESULTS: A total of 15 trappings during September collected a total of 259 female mosquitoes, 97% of which were Culex pipiens sensu lato, as well as 14 honey-baited FTA cards. Eight mosquitoes tested PCR-positive for WNV. Four FTA cards tested PCR-positive for mosquito-borne flaviviruses, two of which were confirmed as WNV, and the remaining two confirmed as Usutu virus. CONCLUSION: The suitability of the FTA cards in preserving viral RNA in the field and rapid turnaround time from collection to result is combined with a simple, cost-effective, and highly specific trapping method to create an arbovirus surveillance system, which circumvents many of the difficulties of previous surveillance programmes that required the analysis of mosquitoes in the laboratory.


Assuntos
Mel , Mosquitos Vetores/virologia , Febre do Nilo Ocidental/transmissão , Vírus do Nilo Ocidental/isolamento & purificação , Animais , Comportamento Alimentar , Feminino , Alemanha , Mosquitos Vetores/fisiologia , RNA Viral/isolamento & purificação , Manejo de Espécimes/instrumentação , Manejo de Espécimes/métodos , Vírus do Nilo Ocidental/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA