Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 278
Filtrar
1.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38833618

RESUMO

AIMS: Debulking of infective mass to reduce the burden if infective material is a fundamental principle in the surgical management of infection. The aim of this study was to investigate the validity of this principle in patients undergoing transvenous lead extraction in the context of bloodstream infection (BSI). METHODS AND RESULTS: We performed an observational single-centre study on patients that underwent transvenous lead extraction due to a BSI, with or without lead-associated vegetations, in combination with a percutaneous aspiration system during the study period 2015-22. One hundred thirty-seven patients were included in the final analysis. In patients with an active BSI at the time of intervention, the use of a percutaneous aspiration system had a significant impact on survival (log-rank: P = 0.0082), while for patients with a suppressed BSI at the time of intervention, the use of a percutaneous aspiration system had no significant impact on survival (log-rank: P = 0.25). CONCLUSION: A reduction of the infective burden by percutaneous debulking of lead vegetations might improve survival in patients with an active BSI.


Assuntos
Remoção de Dispositivo , Infecções Relacionadas à Prótese , Humanos , Feminino , Masculino , Remoção de Dispositivo/métodos , Idoso , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/mortalidade , Pessoa de Meia-Idade , Resultado do Tratamento , Desfibriladores Implantáveis/efeitos adversos , Sucção , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Endocardite Bacteriana/cirurgia , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/etiologia , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais
2.
Clin Infect Dis ; 79(3): 663-671, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-38913722

RESUMO

BACKGROUND: Information on infective endocarditis (IE) caused by Cutibacterium spp. is limited and new Duke-International Society for Cardiovascular Infectious Diseases (ISCVID) criteria have not yet been properly assessed. We examined clinical characteristics, outcomes, and performance of diagnostic tests for Cutibacterium valvular and cardiac implantable electronic device-related IE (CIED-IE). METHODS: Data corresponding to all episodes of Cutibacterium IE recorded from 2008 to 2023 in a prospective national cohort including 46 Spanish hospitals were examined. Possible IE cases were reassessed using the new criteria. The sensitivity of blood cultures, valvular and CIED cultures, and polymerase chain reaction of the 16S rRNA gene and sequencing (16SPCR) was evaluated. RESULTS: Of 6692 episodes of IE, 67 (1%) were caused by Cutibacterium spp. with 85% affecting men. Of these, 50 were valve-related (45 prosthetic, 5 native) and 17 CIED-related. The new criteria identified 8 additional cases and reclassified 15 as definite IE. Intracardiac complications (abscess, pseudoaneurysm, perforation, or intracardiac fistula) occurred in 23 of 50 (46%) valvular IE episodes, leading to 18% mortality, and up to 40% mortality if surgery was indicated but could not be performed. All CIED-IE cases underwent device removal and no deaths were recorded. Positive diagnosis rates for blood cultures, valve/device cultures, and 16SPCR were 52%, 70%, and 82%, respectively. CONCLUSIONS: Cutibacterium IE is a rare yet potentially life-threatening condition that warrants a high index of suspicion in men with endovascular prosthetic material. The new Duke-ISCVID criteria and molecular techniques are useful for its diagnosis. Considering a significant complication rate, cardiac surgery and removal of CIEDs play a key role in reducing mortality.


Assuntos
Endocardite Bacteriana , Infecções Relacionadas à Prótese , Humanos , Masculino , Feminino , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Endocardite Bacteriana/microbiologia , Endocardite Bacteriana/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , RNA Ribossômico 16S/genética , Propionibacteriaceae/isolamento & purificação , Propionibacteriaceae/genética , Próteses Valvulares Cardíacas/efeitos adversos , Próteses Valvulares Cardíacas/microbiologia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Idoso de 80 Anos ou mais , Espanha/epidemiologia , Adulto , Desfibriladores Implantáveis/efeitos adversos
4.
Infect Dis (Lond) ; 56(7): 543-553, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38529922

RESUMO

BACKGROUND: Patients with cardiac implantable electronic device (CIED) and Staphylococcus aureus bacteraemia (SAB) are at risk of having CIED infection, pocket infection or endocarditis. To avoid treatment failures, guidelines recommend that the CIED should be extracted in all cases of SAB butrecent studies indicate low extraction rates and low risk of relapse. The aim of the study was to describe a Swedish population-based cohort of patients with CIED and SAB, the rate of extraction, and treatment failure measured as recurrent SAB. METHODS: Patients identified to have SAB in the Karolinska Laboratory database, serving a population of 1.9 million, from January 2015 through December 2019 were matched to the Swedish ICD and Pacemaker Registry. Patients with CIED and SAB were included. Clinical data were collected from medical records. RESULTS: A cohort of 274 patients was identified and 38 patients (14%)had the CIED extracted. Factors associated with extraction were lower age, lower Charlson comorbidity index, shorter time since CIED implantation, and non-nosocomial acquisition, but not mortality. No patient was put on lifelong antibiotic treatment. Sixteen patients (6%) had a recurrent SAB within one year, two in patients subjected to extraction (5%) and 14 in patients not subjected to CIED-extraction (6%). Three of the 14 patients were found to have definite endocarditis during the recurrent episode. CONCLUSIONS: Despite a low extraction rate, there were few recurrences. We suggest that extraction of the CIED might be omitted if pocket infection, changes on the CIED, or definite endocarditis are not detected.


Assuntos
Bacteriemia , Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Infecções Estafilocócicas , Staphylococcus aureus , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Infecções Estafilocócicas/epidemiologia , Infecções Estafilocócicas/microbiologia , Bacteriemia/epidemiologia , Bacteriemia/microbiologia , Desfibriladores Implantáveis/efeitos adversos , Suécia/epidemiologia , Marca-Passo Artificial/microbiologia , Marca-Passo Artificial/efeitos adversos , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/epidemiologia , Staphylococcus aureus/isolamento & purificação , Remoção de Dispositivo , Recidiva , Fatores de Risco , Antibacterianos/uso terapêutico
5.
J Interv Card Electrophysiol ; 67(5): 1211-1217, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38374300

RESUMO

BACKGROUND: The avascular capsule around the generator of the cardiac implantable electronic device (CIED) could be susceptible to bacterial colonization and source of infection. Capsulectomy during CIED generator replacement may be beneficial in preventing device infection, but there is a lack of evidence. METHODS: This prospective randomized trial, conducted from December 2013 to December 2019, included 195 patients divided equally into two groups. In the intervention group (n = 97), capsule removal was performed on the floor of the pocket, while it was not performed in the control group (n = 98). In both groups, swab culture was performed in the pocket. The primary outcome was the occurrence of device infection requiring pocket revision. RESULTS: A total of 195 patients were included (mean age 70.2 ± 13.6 years, 55.4% women), with an average follow-up period of 54.3 ± 28.9 months. Among 182 patients undergoing microbiological cultures of pockets, 19 (10.4%) were confirmed positive, and Staphylococcus species were identified most frequently. The primary outcome occurred in 4 (2.1%), and there was no significant difference between the two groups (3.1% vs. 1.0%, p = 0.606). Hematoma has occurred in 10 patients (3.1% vs. 7.1%, p = 0.338), one of them required wound revision. In multivariable analysis, the occurrence of hematoma was the only independent risk factor associated with device infection (HR 13.6, 95% CI 1.02-181.15, p = 0.048). CONCLUSIONS: In this long-term prospective study, capsulectomy during the replacement of the generator did not reduce the incidence of device infection. There was no association between bacterial colonization in the capsule around the generator and CIED infection.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Infecções Relacionadas à Prótese , Humanos , Feminino , Masculino , Estudos Prospectivos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Idoso , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Pessoa de Meia-Idade
6.
Curr Cardiol Rep ; 25(8): 781-793, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37351825

RESUMO

PURPOSE OF REVIEW: Bloodstream infection (BSI) in patients with cardiac implantable electronic devices (CIEDs) is common and can prompt challenges in defining optimal management. We provide a contemporary narrative review of this topic and propose a pathogen-dependent clinical approach to patient management. RECENT FINDINGS: BSI due to staphylococci, viridans group streptococci, and enterococci is associated with an increased risk of underlying CIED infection, while the risk of CIED infection due to other organisms is poorly defined. There is growing evidence that positron emission tomography-computed tomography may be helpful in some patients with BSI and underlying CIED. Twenty studies were included to examine the impact of microbiologic findings on the risk of CIED infection among patients with BSI. Diagnosis of CIED infection in patients with BSI without pocket findings is often difficult, necessitating the use of novel diagnostic tools to help guide the clinician in subsequent patient management.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Sepse , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/complicações , Sepse/complicações , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/microbiologia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Estudos Retrospectivos
7.
Heart Rhythm ; 19(6): 901-908, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35124230

RESUMO

BACKGROUND: Device-related infection (DRI) is a severe complication of treatment with cardiac implantable electronic devices. Identification of the causative pathogen is essential for optimal treatment, but conventional methods often are inadequate. OBJECTIVE: The purpose of this study was to improve microbiological diagnosis in DRI using sonication and next-generation sequencing analysis. The primary objective was identification of causative pathogens. The secondary objective was estimation of the sensitivity of different microbiological methods in detecting the causative pathogen. METHODS: Consecutive patients with clinical signs of DRI between October 2016 and January 2019 from 3 tertiary centers in Denmark were included in the study. Patients underwent a diagnostic approach, including blood cultures and perioperative collection of microbiological samples (pocket swab, pocket tissue biopsies, generator, and leads). Conventional culturing was performed, and device components were sonicated and examined with an amplicon-based metagenomic analysis using next-generation sequencing. The results were compared with a reference standard-identified causative pathogen. RESULTS: In 110 patients with clinical signs of pocket (n = 50) or systemic DRI (n = 60), we collected 109 pocket swabs, 220 pocket tissue biopsies, 106 generators, 235 leads, and a minimum 1 set of blood cultures from 102 patients. Combining all findings, we identified the causative pathogen in 95% of cases, irrespective of DRI type. The usability of each microbiological method differed between DRI types. In pocket DRI, next-generation sequencing analysis of generators achieved sensitivity of 90%. For systemic DRI, blood cultures reached sensitivity of 93%. CONCLUSION: Using a strategy including sonication and next-generation sequencing, we identified the causative pathogen in 95% of DRI. Sensitivity of microbiological methods differed according to the type of DRI.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/microbiologia , Eletrônica , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Sonicação/métodos
8.
Microb Drug Resist ; 28(3): 382-385, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34918959

RESUMO

Vancomycin-resistant enterococcal (VRE) bacteremia is associated with higher mortality rates and longer hospitalizations than vancomycin-sensitive enterococcal (VSE) bacteremia. A 67-year-old man with a right psoas abscess and pacemaker-associated tricuspid valve endocarditis in September 2020 grew VSE Enterococcus faecium from blood cultures that cleared after administration of intravenous vancomycin and gentamicin. Subsequently, he underwent tricuspid valve repair, pacemaker removal, and partial lead extraction. Valve and postoperative blood cultures grew VRE E. faecium, which cleared after administration of intravenous daptomycin. One VSE and two VRE isolates were collected and sequenced. All isolates belonged to E. faecium multilocus sequence type ST17 and were closely related, having <20 mutations in pairwise genome comparisons. Vancomycin resistance was due to the acquisition of a plasmid-encoded VanA operon. None of the isolates encoded the virulence factors asa1, gelE, cylA, or hyl; all encoded a homologue of efaAfm. VSE E. faecium, but not VRE E. faecium isolates, encoded a glucose transporter gene mutation. Two VRE E. faecium isolates formed more robust biofilms than the VSE E. faecium isolate (p < 0.001). The VRE E. faecium isolates, which generated larger biofilms than the VSE E. faecium isolate, could have remained protected in the heart valve and only caused bacteremia when disrupted during cardiac surgery. This study demonstrates that bacteria detected in the bloodstream of patients with endocarditis may not fully represent the organisms adherent to the cardiac valves or indwelling devices.


Assuntos
Bacteriemia/microbiologia , Endocardite Bacteriana/microbiologia , Enterococos Resistentes à Vancomicina/isolamento & purificação , Idoso , Antibacterianos/farmacologia , Bacteriemia/tratamento farmacológico , Daptomicina/uso terapêutico , Farmacorresistência Bacteriana Múltipla , Endocardite Bacteriana/tratamento farmacológico , Enterococcus faecium , Genes Bacterianos , Humanos , Masculino , Testes de Sensibilidade Microbiana , Marca-Passo Artificial/microbiologia , Valva Tricúspide/microbiologia , Enterococos Resistentes à Vancomicina/efeitos dos fármacos
10.
Med Microbiol Immunol ; 210(5-6): 245-250, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34254192

RESUMO

Our study aimed to evaluate the sensitivity of the sonication tool for the microbiological diagnosis of cardiovascular implantable electronic device infections (CIEDIs). The extracted cardiac implants of 52 patients were assessed: 19 with CIEDI and 33 with elective generator replacement or revision without clinical infection. Sonication fluid culture of explanted CIEDs yielded higher numbers of microorganisms than pocket tissue or swab cultures. The sensitivity of sonication fluid culture was significantly higher than that of pocket swab and tissue culture for microbiological diagnosis of CIEDI. The microorganisms isolated most frequently via sonication of explanted CIEDs were Gram-positive cocci (70%), of which 50% was coagulase-negative Staphylococcus. Sonication fluid culture detected colonization in 36.4% of the non-infected patients. Sonication fluid culture represents a promising diagnostic strategy with increased sensitivity compared to conventional culture methods for microbiological diagnosis of cardiac devices associated with infection and colonization.


Assuntos
Bactérias/isolamento & purificação , Técnicas Bacteriológicas , Dispositivos de Terapia de Ressincronização Cardíaca/microbiologia , Desfibriladores Implantáveis/microbiologia , Marca-Passo Artificial/microbiologia , Infecções Relacionadas à Prótese/diagnóstico , Sonicação , Adulto , Idoso , Bactérias/crescimento & desenvolvimento , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
11.
Value Health ; 24(7): 930-938, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34243836

RESUMO

OBJECTIVES: To model the cost-effectiveness of the TYRX Absorbable Antibacterial Envelope when used in patients at increased risk of cardiac implantable electronic device (CIED) infection in the context of 3 European healthcare systems: Germany, Italy, and England. METHODS: A decision tree model with a lifetime horizon was populated using data from the Worldwide Randomized Antibiotic Envelope Infection Prevention Trial, a large multicenter randomized controlled trial. Use of the antibacterial envelope adjunctive to standard of care was compared to standard of care infection prevention alone. Patients in the model were divided into subgroups based on presence of factors known to increase infection risk. RESULTS: The antibacterial envelope had the most favorable cost-effectiveness profile when patients had previously experienced CIED infection, had a history of immunosuppressive therapy, or had a Prevention of Arrhythmia Device Infection Trial (PADIT) score indicating high risk of infection (scores ≥6) at cost-effectiveness thresholds of €50 000 in Germany (assumed in the absence of an official threshold), €40 000 in Italy, and £30 000 in England. Probabilistic sensitivity analysis indicated that the antibacterial envelope was likely to be cost-effective in patients with other risk factors (including replacement of high power CIEDs, generator replacement with lead modification, and PADIT scores indicating intermediate risk of infection) when used with some device types and in some countries. CONCLUSIONS: The absorbable antibacterial envelope was associated with cost-effectiveness ratios below European benchmarks in selected patients at increased risk of infection, suggesting the envelope provides value for European healthcare systems by reducing CIED infections.


Assuntos
Antibioticoprofilaxia/economia , Análise Custo-Benefício , Controle de Infecções , Marca-Passo Artificial/microbiologia , Árvores de Decisões , Europa (Continente) , Humanos
12.
Carbohydr Polym ; 245: 116525, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32718629

RESUMO

In this study, we developed an injectable antibacterial hydrogel based on hyaluronic acid (HA) and chlorhexidine (CHX) for cardiovascular implantable electronic device (CIED) infection treatment. To balance stability and moldability, the HA scaffold was pre-crosslinked by 1,4-butanediol diglycidyl ether (BDDE) and then ground to form an HA microgel (CHA). Then, the antibacterial agent CHX was further crosslinked in the CHA microgel through electrostatic interactions between CHA and CHX to obtain hybrid crosslinked hydrogels (CHA/CHX). These hydrogels exhibited shear-thinning/self-recovery behavior, allowing easy injection into the CIED pocket and good matching with the pocket shape without extra space requirements, which represents an improvement on previously reported methods. In vitro and in vivo antibacterial tests showed that the CHA/CHX hydrogels had both good biocompatibility and very effective antibacterial action. The above results indicated that the CHA/CHX hydrogels would be an excellent candidate for CIED pocket infection treatment.


Assuntos
Antibacterianos/química , Antibacterianos/uso terapêutico , Reagentes de Ligações Cruzadas/química , Ácido Hialurônico/química , Hidrogéis/química , Hidrogéis/uso terapêutico , Marca-Passo Artificial/microbiologia , Infecções Estafilocócicas/prevenção & controle , Staphylococcus aureus/efeitos dos fármacos , Animais , Antibacterianos/farmacologia , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/uso terapêutico , Linhagem Celular , Clorexidina/química , Eritrócitos/efeitos dos fármacos , Eritrócitos/metabolismo , Escherichia coli/efeitos dos fármacos , Feminino , Humanos , Hidrogéis/farmacologia , Masculino , Teste de Materiais/métodos , Camundongos , Estrutura Molecular , Coelhos , Reologia/métodos , Infecções Estafilocócicas/microbiologia , Eletricidade Estática
14.
J Cardiovasc Electrophysiol ; 31(3): 712-717, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32009284

RESUMO

INTRODUCTION: Infections of cardiac implantable electronic devices remain a prevalent health concern necessitating the advent of novel preventative strategies. Based on the observation that bacterial infections of the Micra transcatheter pacemaker device are extremely rare, we examine the effect of parylene coating on bacterial adhesion and growth. METHODS: Bacterial growth was compared on polyurethane coated, bare, or parylene coated titanium surfaces. Eight test samples per bacterial species and material combination were incubated with Staphylococcus Aureus or Pseudomonas aeruginosa for 24 hours and then assayed for bacterial growth. The surface contact angle was also characterized by measuring the angle between the tangent to the surface of a liquid droplet made with the surface of the solid sample. RESULTS: The mean bacterial colony counts were significantly reduced for both parylene coated titanium versus bare samples (3.69 ± 0.27 and 4.80 ± 0.48 log[CFU/mL] respectively for S. aureus [P < .001] and 5.51 ± 0.27 and 6.08 ± 0.11 log[CFU/mL] respectively for P. aeruginosa [P < .001]), and for parylene coated titanium versus polyurethane samples (4.27 ± 0.42 and 5.40 ± 0.49 log[CFU/mL] respectively for S. aureus [P < .001] and 4.23 ± 0.42 and 4.84 ± 0.32 log[CFU/mL] respectively for P. aeruginosa [P = .006]). Parylene coated titanium samples had a higher contact angle compared with bare titanium, but lower compared with polyurethane (mean contact angle 87.5 ± 3.1 degrees parylene, 73.3 ± 3.7 degrees titanium [P < .001 vs parylene], and 94.8 ± 3.7 degrees polyurethane [P = .002 vs parylene]). CONCLUSIONS: Parylene coating significantly reduced the ability of bacteria to grow in colony count assays suggesting that this could contribute to the reduction of bacterial infections of Micra transcatheter pacemakers.


Assuntos
Antibacterianos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Contaminação de Equipamentos , Marca-Passo Artificial/microbiologia , Polímeros/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Xilenos/farmacologia , Contagem de Colônia Microbiana , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/crescimento & desenvolvimento
16.
Medicina (B Aires) ; 80(1): 17-22, 2020.
Artigo em Espanhol | MEDLINE | ID: mdl-32044737

RESUMO

Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Endocardite/diagnóstico por imagem , Endocardite/microbiologia , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/microbiologia , Feminino , Fluordesoxiglucose F18 , Próteses Valvulares Cardíacas/microbiologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/microbiologia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Adulto Jovem
17.
Medicina (B.Aires) ; 80(1): 17-22, feb. 2020. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1125033

RESUMO

La endocarditis infecciosa (EI) es una enfermedad grave y potencialmente letal. La capacidad diagnóstica de los criterios de Duke modificados es alta para válvulas nativas, pero decae en el caso de EI de válvulas protésicas o EI asociadas a dispositivos. El ecocardiograma y los hallazgos microbiológicos son fundamentales para el diagnóstico, pero pueden resultar insuficientes en este grupo de pacientes. Nuestro objetivo fue evaluar la utilidad de la tomografía por emisión de positrones y fusión con tomografía computarizada (PET/TC) en pacientes con sospecha de EI, portadores de válvulas protésicas o dispositivos intracardiacos. Se estudiaron 32 pacientes, a los cuales se les realizó un PET/CT con 18F-Flúor desoxiglucosa (18F-FDG). Se consideraron sugestivos de infección aquellos con captación intensa de tipo focal y/o heterogénea con un punto de corte de Standard Uptake Value (SUV) mayor o igual a 3.7. Los diagnósticos iniciales según los criterios de Duke modificados, se compararon con el diagnóstico final establecido por la Unidad de Endocarditis institucional. El agregado del PET/CT a esos criterios, proporcionó un diagnóstico concluyente en 22 de los 32 casos iniciales, reclasificando a 11 casos en EI definitivas y a otros 5 casos como negativos para ese diagnóstico. La EI continúa siendo un grave problema clínico. En aquellos casos donde los criterios de Duke no son suficientes para establecer el diagnóstico y la sospecha clínica persiste, el PET/CT puede ser una herramienta complementaria útil para aumentar la sensibilidad diagnóstica.


Infective endocarditis (IE) is a serious and potentially lethal condition. The diagnostic capacity of the modified Duke criteria is high for native valves, but it declines in the case of EI of prosthetic valves or EI associated with devices. Echocardiography and microbiological findings are essential for diagnosis but may be insufficient in this group of patients. Our objective was to evaluate the usefulness of positron emission tomography and fusion with computed tomography (PET / CT) in patients with suspected IE, carriers of prosthetic valves or intracardiac devices; 32 patients were studied, who underwent PET / CT with 18F-Fluorine deoxyglucose (18F-FDG). Those with intense focal and/or heterogeneous uptake with a Standard Uptake Value (SUV) cut-off point greater than or equal to 3.7 were considered suggestive of infection. The initial diagnoses according to the modified Duke criteria were compared with the final diagnosis established by the Institutional Endocarditis Unit. The addition of PET / CT to these criteria, provided a conclusive diagnosis in 22 of the 32 initial cases reclassifying 11 cases in definitive EI; another 5 cases were negative for that diagnosis. EI continues to be a serious clinical problem. In those cases where the Duke criteria are not sufficient to establish the diagnosis and clinical suspicion persists, PET / CT can be a useful complementary tool to increase the diagnostic sensitivity.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto Jovem , Marca-Passo Artificial/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Endocardite/microbiologia , Endocardite/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Marca-Passo Artificial/microbiologia , Valores de Referência , Próteses Valvulares Cardíacas/microbiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Infecções Relacionadas à Prótese/diagnóstico por imagem , Desfibriladores Implantáveis/microbiologia , Estatísticas não Paramétricas , Fluordesoxiglucose F18
18.
Clin Microbiol Infect ; 26(2): 255.e1-255.e6, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30797886

RESUMO

The rate of cardiac implantable electronic device (CIED) infection is increasing with time. We sought to determine the predictors, relative mortality, and cost burden of early-, mid- and late-onset CIED infections. We conducted a retrospective cohort study of all CIED implantations in Ontario, Canada between April 2013 and March 2016. The procedures and infections were identified in validated, population-wide health-care databases. Infection onset was categorized as early (0-30 days), mid (31-182 days) and late (183-365 days). Cox proportional hazards regression was used to assess the mortality impact of CIED infections, with infection modelled as a time-varying covariate. A generalized linear model with a log-link and γ distribution was used to compare health-care system costs by infection status. Among 17 584 patients undergoing CIED implantation, 215 (1.2%) developed an infection, including 88 early, 85 mid, and 42 late infections. The adjusted hazard ratio (aHR) of death was higher for patients with early (aHR 2.9, 95% CI 1.7-4.9), mid (aHR 3.3, 95% CI 1.9-5.7) and late (aHR 19.9, 95% CI 9.9-40.2) infections. Total mean 1-year health costs were highest for late-onset (mean Can$113 778), followed by mid-onset (mean Can$85 302), and then early-onset (Can$75 415) infections; costs for uninfected patients were Can$25 631. After accounting for patient and procedure characteristics, there was a significant increase in costs associated with early- (rate ratio (RR) 3.1, 95% CI 2.3-4.1), mid- (RR 2.8, 95% CI 2.4-3.3) and late- (RR 4.7, 95% CI 3.6-6.2) onset infections. In summary, CIED infections carry a tremendous clinical and economic burden, and this burden is disproportionately high for late-onset infections.


Assuntos
Efeitos Psicossociais da Doença , Desfibriladores Implantáveis/economia , Cardiopatias/economia , Marca-Passo Artificial/economia , Infecções Relacionadas à Prótese/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/microbiologia , Feminino , Custos de Cuidados de Saúde , Cardiopatias/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Ontário , Marca-Passo Artificial/microbiologia , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Fatores de Risco , Infecção da Ferida Cirúrgica/economia
19.
Clin Nucl Med ; 45(1): e55-e56, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31246690

RESUMO

A 59-year-old man with a pacemaker who was admitted for evaluation of fever was found to have a redundant loop of the ventricular lead and a vegetation attached to it. An FDG PET/CT revealed a focus of FDG uptake at the ventricular lead loop. Surgical extraction of the pacemaker device confirmed a Propionibacterium acnes pacemaker endocarditis. We hypothesize that the redundant loop of the ventricular lead induced a chronic mechanical stress both to the tricuspid valve and to the lead itself, facilitating the bacterial colonization of the lead.


Assuntos
Endocardite Bacteriana/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/microbiologia , Marca-Passo Artificial/microbiologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Propionibacterium acnes/fisiologia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
20.
Pacing Clin Electrophysiol ; 42(10): 1331-1339, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31424091

RESUMO

BACKGROUND: Enterococcal cardiovascular implantable electronic device (CIED) infections are not well characterized. METHODS: Data from the Multicenter Electrophysiologic Device Infection Cohort, a prospective study of CIED infections, were used for descriptive analysis of adults with enterococcal CIED infections. RESULTS: Of 433 patients, 21 (4.8%) had enterococcal CIED infection. Median age was 71 years. Twelve patients (57%) had permanent pacemakers, five (24%) implantable cardioverter defibrillators, and four (19%) biventricular devices. Median time from last procedure to infection was 570 days. CIED-related bloodstream infections occurred in three patients (14%) and 18 (86%) had infective endocarditis (IE), 14 (78%) of which were definite by the modified Duke criteria. IE cases were classified as follows: valvular IE, four; lead IE, eight; both valve and lead IE, six. Vegetations were demonstrated by transesophageal echocardiography in 17 patients (81%). Blood cultures were positive in 19/19 patients with confirmed results. The most common antimicrobial regimen was penicillin plus an aminoglycoside (33%). Antibiotics were given for a median of 43 days. Only 14 patients (67%) underwent device removal. There was one death during the index hospitalization with four additional deaths within 6 months (overall mortality 24%). There were no relapses. CONCLUSIONS: Enterococci caused 4.8% of CIED infections in our cohort. Based on the late onset after device placement or manipulation, most infections were likely hematogenous in origin. IE was the most common infection syndrome. Only 67% of patients underwent device removal. At 6 months follow-up, no CIED infection relapses had occurred, but overall mortality was 24%.


Assuntos
Desfibriladores Implantáveis/microbiologia , Endocardite Bacteriana/microbiologia , Enterococcus/isolamento & purificação , Infecções por Bactérias Gram-Positivas/microbiologia , Marca-Passo Artificial/microbiologia , Complicações Pós-Operatórias/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Ecocardiografia Transesofagiana , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/tratamento farmacológico , Feminino , Infecções por Bactérias Gram-Positivas/diagnóstico por imagem , Infecções por Bactérias Gram-Positivas/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/tratamento farmacológico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA