Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.803
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 545, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730391

RESUMO

BACKGROUND: This Finite Element Analysis was conducted to analyze the biomechanical behaviors of titanium base abutments and several crown materials with respect to fatigue lifetime and stress distribution in implants and prosthetic components. METHODS: Five distinct designs of implant-supported single crowns were modeled, including a polyetheretherketone (PEEK), polymer-infiltrated ceramic network, monolithic lithium disilicate, and precrystallized and crystallized zirconia-reinforced lithium silicates supported by a titanium base abutment. For the static load, a 100 N oblique load was applied to the buccal incline of the palatal cusp of the maxillary right first premolar. The dynamic load was applied in the same way as in static loading with a frequency of 1 Hz. The principal stresses in the peripheral bone as well as the von Mises stresses and fatigue strength of the implants, abutments, prosthetic screws, and crowns were assessed. RESULTS: All of the models had comparable von Mises stress values from the implants and abutments, as well as comparable maximum and minimum principal stress values from the cortical and trabecular bones. The PEEK crown showed the lowest stress (46.89 MPa) in the cervical region. The prosthetic screws and implants exhibited the highest von Mises stress among the models. The lithium disilicate crown model had approximately 9.5 times more cycles to fatique values for implants and 1.7 times more cycles to fatique values for abutments than for the lowest ones. CONCLUSIONS: With the promise of at least ten years of clinical success and favorable stress distributions in implants and prosthetic components, clinicians can suggest using an implant-supported lithium disilicate crown with a titanium base abutment.


Assuntos
Benzofenonas , Coroas , Dente Suporte , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Análise de Elementos Finitos , Titânio , Titânio/química , Humanos , Porcelana Dentária/química , Polietilenoglicóis/química , Materiais Dentários/química , Polímeros , Cetonas/química , Zircônio/química , Implantes Dentários para Um Único Dente , Teste de Materiais , Projeto do Implante Dentário-Pivô , Fenômenos Biomecânicos
2.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730400

RESUMO

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Assuntos
Resinas Compostas , Infiltração Dentária , Resistência à Flexão , Dureza , Teste de Materiais , Propriedades de Superfície , Técnicas In Vitro , Humanos , Análise do Estresse Dentário , Materiais Dentários/química , Estresse Mecânico , Polietilenoglicóis , Ácidos Polimetacrílicos/química , Bis-Fenol A-Glicidil Metacrilato
3.
Am J Dent ; 37(2): 66-70, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38704848

RESUMO

PURPOSE: To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation. METHODS: 160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al2O3-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al2O3-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests. RESULTS: There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS. CLINICAL SIGNIFICANCE: As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al2O3-impregnated discs had the smoothest surfaces.


Assuntos
Óxido de Alumínio , Resinas Compostas , Polimento Dentário , Saliva Artificial , Compostos de Silício , Propriedades de Superfície , Resinas Compostas/química , Polimento Dentário/métodos , Humanos , Saliva Artificial/química , Concentração de Íons de Hidrogênio , Óxido de Alumínio/química , Compostos de Silício/química , Compostos Inorgânicos de Carbono/química , Teste de Materiais , Nanocompostos/química , Ácido Cítrico/química , Saliva/enzimologia , Saliva/metabolismo , Saliva/química , Erosão Dentária , Borracha/química , Materiais Dentários/química
4.
BMC Oral Health ; 24(1): 557, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38735940

RESUMO

BACKGROUND: Dental resin-based composites are widely recognized for their aesthetic appeal and adhesive properties, which make them integral to modern restorative dentistry. Despite their advantages, adhesion and biomechanical performance challenges persist, necessitating innovative strategies for improvement. This study addressed the challenges associated with adhesion and biomechanical properties in dental resin-based composites by employing molecular docking and dynamics simulation. METHODS: Molecular docking assesses the binding energies and provides valuable insights into the interactions between monomers, fillers, and coupling agents. This investigation prioritizes SiO2 and TRIS, considering their consistent influence. Molecular dynamics simulations, executed with the Forcite module and COMPASS II force field, extend the analysis to the mechanical properties of dental composite complexes. The simulations encompassed energy minimization, controlled NVT and NPT ensemble simulations, and equilibration stages. Notably, the molecular dynamics simulations spanned a duration of 50 ns. RESULTS: SiO2 and TRIS consistently emerged as influential components, showcasing their versatility in promoting solid interactions. A correlation matrix underscores the significant roles of van der Waals and desolvation energies in determining the overall binding energy. Molecular dynamics simulations provide in-depth insights into the mechanical properties of dental composite complexes. HEMA-SiO2-TRIS excelled in stiffness, BisGMA-SiO2-TRIS prevailed in terms of flexural strength, and EBPADMA-SiO2-TRIS offered a balanced combination of mechanical properties. CONCLUSION: These findings provide valuable insights into optimizing dental composites tailored to diverse clinical requirements. While EBPADMA-SiO2-TRIS demonstrates distinct strengths, this study emphasizes the need for further research. Future investigations should validate the computational findings experimentally and assess the material's response to dynamic environmental factors.


Assuntos
Materiais Biocompatíveis , Resinas Compostas , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Dióxido de Silício , Resinas Compostas/química , Dióxido de Silício/química , Materiais Biocompatíveis/química , Materiais Dentários/química , Metacrilatos/química , Poliuretanos/química , Ácidos Polimetacrílicos/química , Polietilenoglicóis/química , Resinas Acrílicas/química
5.
BMC Oral Health ; 24(1): 523, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702708

RESUMO

BACKGROUND: The rising demand for improved aesthetics has driven the utilization of recently introduced aesthetic materials for creating custom post and core restorations. However, information regarding the fracture resistance of these materials remains unclear, which limits their practical use as custom post and core restorations in clinical applications. AIM OF THE STUDY: This study aimed to evaluate the fracture resistance of three non-metallic esthetic post and core restorations and their modes of failure. MATERIALS AND METHODS: Thirty-nine single-rooted human maxillary central incisors were endodontically treated. A standardized post space preparation of 9mm length was performed to all teeth to receive custom-made post and core restorations. The prepared teeth were randomly allocated to receive a post and core restoration made of one of the following materials (n=13): glass fiber-reinforced composite (FRC), polyetheretherketone (PEEK) and polymer-infiltrated ceramic-network (PICN). An intraoral scanner was used to scan all teeth including the post spaces. Computer-aided design and computer-aided manufacturing (CAD-CAM) was used to fabricate post and core restorations. Post and core restorations were cemented using self-adhesive resin cement. All specimens were subjected to fracture resistance testing using a universal testing machine. Failure mode analysis was assessed using a stereomicroscope and SEM. The data was statistically analyzed using One-Way ANOVA test followed by multiple pairwise comparisons using Bonferroni adjusted significance level. RESULTS: Custom PEEK post and core restorations displayed the least fracture load values at 286.16 ± 67.09 N. In contrast, FRC exhibited the highest average fracture load at 452.60 ± 105.90 N, closely followed by PICN at 426.76 ± 77.99 N. In terms of failure modes, 46.2% of specimens with PICN were deemed non-restorable, while for PEEK and FRC, these percentages were 58.8% and 61.5%, respectively. CONCLUSIONS: Within the limitation of this study, both FRC and PICN demonstrated good performance regarding fracture resistance, surpassing that of PEEK.


Assuntos
Resinas Compostas , Desenho Assistido por Computador , Falha de Restauração Dentária , Estética Dentária , Técnica para Retentor Intrarradicular , Humanos , Cerâmica , Análise do Estresse Dentário , Benzofenonas , Incisivo/lesões , Materiais Dentários/química , Polietilenoglicóis , Cetonas/química , Polímeros , Vidro , Teste de Materiais , Planejamento de Prótese Dentária
6.
J Contemp Dent Pract ; 25(3): 245-249, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690698

RESUMO

AIM: The aim of the study is to determine the difference in the shear bond strengths to dentin among dental composite (Filtek Z350®, 3M), compomer (Dyract Flow®, Dentsply) and Giomer (Beautifil®, Shofu) with 3MTM Single BondTM Universal Adhesive (SBU) (7th generation, self-etch, single solution adhesive) and AdperTM Single Bond 2 Adhesive (ASB) (5th generation, total-etch, two solution adhesive). MATERIALS AND METHODS: Sixty extracted human permanent teeth were collected, cleansed of debris, and placed in distilled water. The samples were segregated into two groups depicting the two bonding agents-AdperTM (ASB) and 3MTM Single Bond Universal (SBU) and sub-grouped into three groups depicting the three restorative materials (Composite, Giomer, and Compomer) used. Groups were respresented as follows: Group I-ASB + Composite; Group II-ASB + Giomer; Group III-ASB + Compomer; Group IV-SBU + Giomer; Group V-SBU + Compomer; Group VI-SBU + Composite. After applying the bonding agent as per the manufacturer's instructions, following which the restorative material was placed. A Universal Testing Machine (Instron 3366, UK) was employed to estimate the shear bond strength of the individual restorative material and shear bond strengths were calculated. RESULTS: Composite bonded with SBU (group VI) displayed the greatest shear strength (11.16 ± 4.22 MPa). Moreover, Giomers and flowable compomers displayed better bond strengths with ASB compared with their SBU-bonded counterparts. CONCLUSION: These results mark the importance of careful material selection in clinical practice and the bonding agent used to achieve optimal bond strength and enhance the clinical longevity and durability of dental restorations. CLINICAL SIGNIFICANCE: From a clinical perspective, to avoid a compressive or a shear failure, it would be preferrable to use a direct composite restorative material with SBU (Single bond universal adhesive, 7th generation) to achieve maximum bond strength. How to cite this article: Kuchibhotla N, Sathyamoorthy H, Balakrishnan S, et al. Effect of Bonding Agents on the Shear Bond Strength of Tooth-colored Restorative Materials to Dentin: An In Vitro Study. J Contemp Dent Pract 2024;25(3):245-249.


Assuntos
Compômeros , Resinas Compostas , Colagem Dentária , Análise do Estresse Dentário , Adesivos Dentinários , Dentina , Resistência ao Cisalhamento , Resinas Compostas/química , Humanos , Colagem Dentária/métodos , Adesivos Dentinários/química , Técnicas In Vitro , Compômeros/química , Bis-Fenol A-Glicidil Metacrilato , Restauração Dentária Permanente/métodos , Teste de Materiais , Cimentos de Ionômeros de Vidro/química , Materiais Dentários/química , Resinas Acrílicas/química
7.
J Contemp Dent Pract ; 25(3): 221-225, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690693

RESUMO

AIM: This study aimed to assess the color stability of bioactive restorative materials vs nanohybrid resin composites after 3 months of immersion in three frequently consumed beverages. MATERIALS AND METHODS: Thirty disk-shaped specimens of Giomer dental restorative material (Shofu, Japan) and nanohybrid resin composite (Tokuyama, Japan) were performed using a Teflon mold. Super-Snap system (Shofu, Japan) was utilized to finish and polish the specimens to be preserved for 24 hours in distilled water at 37°C. The samples had been divided into three subgroups (Coffee, tea, Pepsi) (n = 5). The initially displayed color measurements of the samples were performed using a spectrophotometer (VITA Easyshade® V). After 7 days, 30 days, and 90 days, color measurements were repeated, and the E of each sample was estimated. E of each sample was calculated. RESULTS: The Giomer group showed statistically significant higher E values than the nanohybrid resin composite where the p-value was ≤0.0001. Tea subgroup showed the highest statistically significant E values in both groups where the p-value was ≤ 0.0001. The highest statistically significant color change was recorded at 3 months. CONCLUSION: The color of bioactive restorative material is less stable if compared with nanohybrid resin composite. CLINICAL SIGNIFICANCE: As tea and coffee are popular beverages, particularly in Middle Eastern nations, dentists must advise patients about the color change of resin restorations. Patients are advised to brush their teeth immediately after consuming these beverages. How to cite this article: Saber EH, Abielhassan MH, Abed YA, et al. Color Stability of Bioactive Restorative Material vs Nanohybrid Resin Composite: An In Vitro Study. J Contemp Dent Pract 2024;25(3):221-225.


Assuntos
Cor , Resinas Compostas , Teste de Materiais , Chá , Resinas Compostas/química , Técnicas In Vitro , Café , Espectrofotometria , Restauração Dentária Permanente , Nanocompostos/química , Materiais Dentários/química , Humanos , Bebidas
8.
J Contemp Dent Pract ; 25(3): 241-244, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38690697

RESUMO

AIM: The current study was designed to assess the linear dimensional changes and adaptability of two heat-cured denture base resins using various cooling methods. MATERIALS AND METHODS: To prepare a total of 90 acrylic resin samples (45 acrylic resin samples for each material), four rectangular stainless-steel plates measuring 25 × 25 × 10 mm were fabricated. For both groups, the material was put into the mold at the dough stage. Group I - SR Triplex Hot Heat Cure acrylic; group II - DPI Heat Cure acrylic. Both groups used the same curing procedure. One of the following three techniques was used to cool the material (15 samples from each material) once the curing cycle was finished: (A) water bath, (b) quenching, and (C) air. A traveling microscope was used to measure the distance between the markings on the acrylic samples. The data was recorded and statistically analyzed. RESULTS: In SR Triplex Hot heat cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.242 ± 0.05), followed by the air technique (0.168 ± 0.11) and the least was found in the water bath technique (0.146 ± 0.01). In DPI Heat Cure acrylic material, the maximum linear dimensional changes were found in the quenching technique (0.284 ± 0.09), followed by the air technique (0.172 ± 0.18) and the least was found in the water bath technique (0.158 ± 0.10). There was a statistically significant difference found between these three cooling techniques. On comparison of adaptability, the water bath technique, the marginal gap SR Triplex Hot was 0.012 ± 0.02 and DPI Heat Cure was 0.013 ± 0.02. In the quenching technique, the marginal gap SR Triplex Hot was 0.019 ± 0.04 and DPI Heat Cure was 0.016 ± 0.04. In the air technique, the marginal gap SR Triplex Hot was 0.017 ± 0.01 and DPI Heat Cure was 0.019 ± 0.01. CONCLUSION: The present study concluded that among the different cooling methods, the water bath technique had the least linear dimensional change, followed by the air and quenching techniques. When comparing the materials, DPI Heat Cure acrylic resin showed a greater linear dimensional change than SR Triplex Hot heat cure acrylic resin. CLINICAL SIGNIFICANCE: During polymerization, heat-cured acrylic resins experience dimensional changes. Shrinkage and expansion are dimensional changes that occur in heat-cured acrylic resins and have an impact on the occlusal relationship and denture fit. However, the denture base's material qualities and the different temperature variations it experiences during production may have an impact on this. How to cite this article: Kannaiyan K, Rathod A, Bhushan P, et al. Assessment of Adaptability and Linear Dimensional Changes of Two Heat Cure Denture Base Resin with Different Cooling Techniques: An In Vitro Study. J Contemp Dent Pract 2024;25(3):241-244.


Assuntos
Resinas Acrílicas , Bases de Dentadura , Temperatura Alta , Teste de Materiais , Resinas Acrílicas/química , Técnicas In Vitro , Temperatura Baixa , Materiais Dentários/química
9.
J Dent ; 144: 104987, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580056

RESUMO

OBJECTIVES: To evaluate whether post-milling firing and material type affect the fabrication trueness and internal fit of lithium disilicate crowns. METHODS: A prefabricated cobalt chromium abutment was digitized to design a mandibular right first molar crown. This design file was used to fabricate crowns from different lithium disilicate ceramics (nano-lithium disilicate (AM), fully crystallized lithium disilicate (IN), advanced lithium disilicate (TS), and lithium disilicate (EX)) (n = 10). Crowns, the abutment, and the crowns when seated on the abutment were digitized by using an intraoral scanner. Fabrication trueness was assessed by using the root mean square method, while the internal fit was evaluated according to the triple scan method. These processes were repeated after the post-milling firing of AM, TS, and EX. Paired samples t-tests were used to analyze the effect of post-milling firing within AM, TS, and EX, while all materials were compared with 1-way analysis of variance and Tukey HSD tests (α = 0.05). RESULTS: Post-milling firing reduced the surface deviations and internal gap of AM and EX (P ≤ 0.014). AM mostly had higher deviations and internal gaps than other materials (P ≤ 0.030). CONCLUSIONS: Post-milling firing increased the trueness and internal fit of tested nano-lithium disilicate and lithium disilicate ceramics. Nano-lithium disilicate mostly had lower trueness and higher internal gap; however, the maximum meaningful differences among tested materials were small. Therefore, the adjustment duration and clinical fit of tested crowns may be similar. CLINICAL SIGNIFICANCE: Tested lithium disilicate ceramics may be suitable alternatives to one another in terms of fabrication trueness and internal fit, considering the small differences in measured deviations and internal gaps.


Assuntos
Desenho Assistido por Computador , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Teste de Materiais , Porcelana Dentária/química , Humanos , Dente Suporte , Cerâmica/química , Propriedades de Superfície , Materiais Dentários/química , Adaptação Marginal Dentária , Ligas de Cromo/química
10.
J Indian Prosthodont Soc ; 24(2): 186-195, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38650344

RESUMO

AIM: (1) To compare the temperature rise in the pulp chamber with different resin materials used for making provisional fixed partial dentures in anterior and posterior region while using Polyvinylsiloxane impression materials as matrix. (2) To identify a superior provisionalization material based on the amount of heat dissipated suitable for anterior and posterior provisional fixed partial denture fabrication. SETTINGS AND DESIGN: Temporary crowns and bridges are integral to Fixed Prosthodontics. It has been observed that conventional fixed prosthesis temporisation materials release heat due to the exothermic polymerisation reaction. When such a provisional material is directly let to set on a vital tooth, the heat transfer causes irreversible changes in the pulp tissue depending of the degree of change. Hence, this study observes amount of heat generation in various materials during temporisation procedure, by simulating similar conditions. MATERIALS AND METHODS: Two Models were fabricated, one simulating missing lateral incisor (Model A) and another simulating missing first molar (Model B). Intact maxillary central incisors and canine for Model A and intact mandibular Second Premolar and Second Molar were selected to act as abutments. These abutment teeth were fitted with the tip of a K-type Thermocouple inside their pulp chambers and these were connected to a digital thermometer. Five temporisation materials were chosen for fabrication of temporary crowns through Direct technique. (1) polymethy methacrylate (Self Cure acrylic), (2) bisacryl composite (Protemp 4), (3) visible light cure urethane dimethacrylate (Revotec LC), (4) barium glass and fumed silica infused methacrylate (Dentsply Integrity) and (5)nano-hybrid composite (VOCO Structur 3). Ten observations were made for each provisional material on each model. During each observation, temperature rise was recorded at 30s interval from the time of application, through the peak and till a decrease in temperature is observed. Polyvinyl siloxane was used as matrix for all except light cure resin, where polypropylene sheet was used. STATISTICAL ANALYSIS USED: Anova test used for statistical. RESULTS: ANOVA test revealed that there was a significant difference in the temperature changes associated with the provisional restorative materials used. Among the five, polymethy methacrylate (self cure resin) showed the maximum rise in temperature, followed by bisacryl composite (Protemp 4), visible light cure urethane dimethacrylate (Revotec LC), barium glass and fumed silica infused methacrylate (Dentsply Integrity) and nano-hybrid composite (VOCO Structur 3). There was no comparable difference between Model A and B but an overall reduction of temperature rise was observed in model B. CONCLUSION: VOCO Structur 3 showed the least temperature rise in the pulp chamber, and overall temperature rise was less for model B which can be attributed to the residual dentin thickness.


Assuntos
Polimerização , Humanos , Cavidade Pulpar , Siloxanas/química , Técnicas In Vitro , Teste de Materiais/métodos , Resinas Compostas/química , Restauração Dentária Temporária/métodos , Prótese Parcial Fixa , Temperatura , Materiais para Moldagem Odontológica/química , Materiais Dentários/química
11.
Eur J Oral Sci ; 132(3): e12987, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38616404

RESUMO

Resin-based three-dimensional (3D) printing finds extensive application in the field of dentistry. Although studies of cytotoxicity, mechanical and physical properties have been conducted for newly released 3D printing resins such as Crowntec (Saremco), Temporary Crown Resin (Formlabs) and Crown & Bridge (Nextdent), the resistance of these materials to esterases in saliva has not been demonstrated at the molecular level. Therefore, in this study, the binding affinities and stability of these new 3D printing resins to the catalytic sites of esterases were investigated using molecular docking and molecular mechanics with Poisson-Bolzmann and surface area solvation (MM/PBSA) methods after active pocket screening. Toxicity predictions of the materials were also performed using ProTox-II and Toxtree servers. The materials were analyzed for mutagenicity, cytotoxicity, and carcinogenicity, and LD50 values were predicted from their molecular structures. The results indicated that out of the three novel 3D printing materials, Nexdent exhibited reduced binding affinity to esterases, indicating enhanced resistance to enzymatic degradation and possessing a superior toxicity profile.


Assuntos
Simulação de Acoplamento Molecular , Impressão Tridimensional , Humanos , Esterases/metabolismo , Esterases/química , Animais , Teste de Materiais , Materiais Dentários/química
12.
Eur J Oral Sci ; 132(3): e12989, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38679835

RESUMO

This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.


Assuntos
Colagem Dentária , Porcelana Dentária , Análise do Estresse Dentário , Facetas Dentárias , Teste de Materiais , Microscopia Eletrônica de Varredura , Difração de Raios X , Zircônio , Zircônio/química , Porcelana Dentária/química , Propriedades de Superfície , Cerâmica/química , Materiais Dentários/química , Humanos
13.
Niger J Clin Pract ; 27(4): 496-503, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38679773

RESUMO

BACKGROUND: Monolithic zirconia restorations can be produced from self-colored or uncolored blocks. The coloring procedure of uncolored blocks and surface treatments may affect the appearance of the restoration. AIM: The purpose of this study is to evaluate the effect of liquid coloring and surface treatments on optical properties of translucent monolithic zirconia. METHODS: All specimens were cut from zirconia blocks with a thickness of 1 mm. Specimens were dipped in the coloring liquids for 3 min, 5 min, and 7 min and then divided into groups of 10 specimens for surface treatments. Glaze and mechanical polishing were applied, and the color of the specimens was measured under the D65 lighting condition with a spectrophotometer device. Color values obtained from the CIE Lab formula and the translucency parameter (TP), opalescence parameter (OP), and contrast ratio (CR) were calculated. The normality of the data was confirmed with the Shapiro-Wilk test. A three-way analysis of variance (ANOVA) was used to assess the effect of dipping time, liquid shade, and surface treatments. RESULTS: The effect of liquid shade and dipping time on the TP, OP, and CR parameters were statistically significant, and the TP values were reduced with the application of coloring liquid. Mechanical polishing groups had higher OP values and lower TP values than glazed groups. CONCLUSION: In cases where high translucency is required, it may be advisable to use self-colored blocks and apply glaze as a surface treatment to achieve the desired optical properties.


Assuntos
Propriedades de Superfície , Zircônio , Zircônio/química , Humanos , Teste de Materiais , Cor , Espectrofotometria , Materiais Dentários/química , Fatores de Tempo , Corantes , Polimento Dentário/métodos
14.
Int J Prosthodont ; 37(2): 173-180, 2024 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648165

RESUMO

PURPOSE: To evaluate the marginal integrity of three inlay-retained fixed dental prosthesis (IRFDP) designs fabricated using monolithic zirconia. MATERIALS AND METHODS: In total, 30 IRFDPs were fabricated using 4-YTZP monolithic zirconia and randomly divided into three groups according to the cavity design. Groups ID2 and ID1.5 received an inlay cavity preparation, which includes a proximal box and an occlusal extension with a depth of 2 mm or 1.5 mm, respectively. Group PB received a proximal box cavity preparation without an occlusal extension. The restorations were fabricated and cemented using a dual-cure resin cement (Panavia V5) and subjected to an equivalent of 5 years of aging. The specimens were evaluated under an SEM to measure marginal continuity before and after the aging process. RESULTS: During the whole 5-year aging process, no specimens showed signs of cracking, fracture, or loss of retention in any restorations. In the SEM analysis, most marginal defects observed in the restorations were areas of microgaps at the tooth/cement interface (TC) or zirconia/cement interface (ZC), resulting in loss of adaptation. There was a significant difference between the groups after the aging process at both the TC (F = 4.762, P < .05) and ZC (F = 6.975, P < .05), with Group ID2 presenting the best performance. There was a significant difference between TC and ZC in all groups (P < .05), with ZC presenting more gaps in all groups. CONCLUSIONS: Inlay cavity designs including a proximal box and an occlusal extension exhibited better marginal stability than a proximal box without occlusal extension.


Assuntos
Restaurações Intracoronárias , Zircônio , Zircônio/química , Humanos , Técnicas In Vitro , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Planejamento de Dentadura , Prótese Parcial Fixa , Materiais Dentários/química
15.
J Prosthet Dent ; 131(5): 933.e1-933.e7, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38429151

RESUMO

STATEMENT OF PROBLEM: The connector height and retainer occlusal thickness of fixed partial dentures (FPDs) may affect restoration longevity. PURPOSE: The purpose of this in vitro study was to determine and compare the fracture resistance of 4-unit monolithic 5% yttria tetragonal zirconia polycrystal (5Y-TZP) FPDs made with different connector heights and retainer occlusal thicknesses after thermomechanical aging. MATERIAL AND METHODS: Forty test metal dies were duplicated from a master metal die containing 2 anatomic abutment preparations of the mandibular right first premolar and second molar for a 4-unit FPD. The dies were divided into 2 groups of 20 each for the fabrication of 4-unit FPDs, with 2-mm and 4-mm uniform connector heights at all 3 connectors, resulting in 6.3-mm2 and 12.6-mm2 connector areas. Each of these groups was further divided into 2 subgroups based on the occlusal thickness of the 2 retainers of 1 mm and 2 mm (n=10). Polyvinyl siloxane impressions of the test metal dies were made and poured in Type V dental stone. Laboratory scans were performed on all the stone dies, and 40 5Y-TZP FPDs (Ceramill Zolid FX) were designed and fabricated. Subsequently, all the FPDs were luted on to the metal dies with a self-adhesive resin cement. The FPDs were preloaded (400 000 mechanical cycles; 4000 thermocycles) using a mastication simulator and tested for axial compressive strength. Two-way analysis of variance (ANOVA) was used to examine the effect of connector and occlusal thicknesses on the fracture load (α=.05). The data were further assessed using the post hoc Tukey HSD multiple comparison test (α=.05). RESULTS: The mean fracture load values were between 737 N and 1563 N. Significant differences in the mean fracture load were found between the connector heights (601 N; P<.001) and occlusal thicknesses (225 N; P=.002), but the interaction of the 2 factors was not significant (P=.132) The Tukey post hoc analysis showed significant differences between the connector thicknesses groups (P<.01), but the occlusal thicknesses were found to be similar for the same connector height (P=.609) CONCLUSIONS: Connector height and occlusal retainer thickness influenced the fracture load of 4-unit monolithic 5Y-TZP FPDs after thermomechanical aging.


Assuntos
Análise do Estresse Dentário , Planejamento de Dentadura , Prótese Parcial Fixa , Ítrio , Zircônio , Zircônio/química , Ítrio/química , Falha de Restauração Dentária , Humanos , Teste de Materiais , Técnicas In Vitro , Materiais Dentários/química , Dente Suporte
16.
J Prosthet Dent ; 131(5): 935.e1-935.e8, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38431509

RESUMO

STATEMENT OF PROBLEM: Computer-aided design and computer-aided manufacturing (CAD-CAM) materials have become popular for dental restorations; however, which materials should be preferred in terms of surface properties after biofilm formation is unclear. PURPOSE: The purpose of this in vitro study was to investigate the effect of biofilm formation on the discoloration properties of resin-infiltrated ceramic and glass-ceramic CAD-CAM materials and human teeth and to examine the effect of the brushing procedure on color change. MATERIAL AND METHODS: One hundred and six 2-mm-thick specimens were prepared from IPS e.max CAD and Cerasmart, and a total of 53 intact human teeth were used. Five specimens from each group were used to measure the amount of live biomass in the biofilm. The remaining 48 specimens in each group were divided into 4 subgroups: kept in distilled water without the formation of dental biofilm (DW), kept in tea without the formation of dental biofilm (T), kept in distilled water after the formation of dental biofilm (DWB), and kept in tea after the formation of dental biofilm (TB) (n=12). After finishing and polishing the materials, initial color measurements were made using a spectrophotometer, and surface roughness measurements were made using noncontact profilometer. After creating a biofilm layer in DWB and TB, all specimens were kept in their solutions at 37 °C for 24 hours, and the color measurements were repeated. After the biofilm layer had been removed by brushing, a third color measurement was made. The data were statistically analyzed with one-way analysis of variance (ANOVA) and two-way ANOVA (α=.05). RESULTS: The lowest roughness value was observed in Cerasmart. Tooth-IPS e.max CAD gave similar results. The Cerasmart material had the most viable biomass, whereas the IPS e.max CAD material had the least. TB had the highest ΔE1 value for all materials and DW had the lowest (P<.05). The brushing procedure caused the materials to return to their initial colors or reduce the color change in most groups. CONCLUSIONS: The presence of biofilm on CAD-CAM materials immersed in distilled water caused an unacceptable degree of discoloration (ΔE>1.8), and immersion in tea led to greater color change. The adhesion of biofilm to restorative dental materials plays an important role in the coloring of these dental materials.


Assuntos
Biofilmes , Cerâmica , Cor , Desenho Assistido por Computador , Porcelana Dentária , Propriedades de Superfície , Cerâmica/química , Humanos , Teste de Materiais , Técnicas In Vitro , Materiais Dentários/química , Escovação Dentária , Resinas Sintéticas
17.
J Prosthet Dent ; 131(5): 934.e1-934.e7, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38431508

RESUMO

STATEMENT OF PROBLEM: Zirconium dioxide (zirconia) cannot be etched in a clinical setting, but zirconia restorations with minimal to no micromechanical bonding are approved and widely used in contemporary dentistry. However, information on the shear bond strength of zirconia and adhesive cement, on the effect of an added proportion of yttria, and on the effect of aging is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the shear bond strength of cement luted to zirconia and the effect of aging. MATERIAL AND METHODS: A total of 131 test specimens were made from 4 zirconia materials with different amounts of yttria added to formulate yttria-partially stabilized zirconia (Y-PSZ); 3Y-PSZ (n=32), 4Y-PSZ (n=34), and 2 5Y-PSZs (n=32 and n=33). A dual-polymerizing cement and 10-methacryloyloxydecyl dihydrogen phosphate-containing primer were used. All specimens were stored in water at 37 °C, half of them for 24 hours and the other half for 6 months. After aging, the specimens were subjected to a shear bond strength test with a notched crosshead according to the International Organization for Standardization (ISO) 29022:2013 standard. The data were analyzed using the independent 2-sample t test, ANOVA, and the Levene test (α=.05). RESULTS: The 3Y-PSZ material had higher mean ±standard deviation shear bond strength (31.83 ±12.80 MPa) compared with 4Y-PSZ (23.34 ±7.66 MPa) after 24 hours of aging in water and higher (28.98 ±14.03 MPa) than 4Y-PSZ (14.35 ±9.62 MPa) and one of the 5Y-PSZ (16.05 ±11.34 MPa) after 6 months. Debonding before loading occurred in all groups except for one of the 5Y-PSZ groups. CONCLUSIONS: Zirconia without macromechanical retention, regardless of an added proportion of yttria, showed high shear bond strength, but the tested materials also had a high coefficient of variance, which, in practice, leads to the risk of the occasional debonding of zirconia restorations.


Assuntos
Colagem Dentária , Análise do Estresse Dentário , Resistência ao Cisalhamento , Ítrio , Zircônio , Zircônio/química , Ítrio/química , Colagem Dentária/métodos , Cimentos Dentários/química , Cimentos de Resina/química , Teste de Materiais , Humanos , Técnicas In Vitro , Materiais Dentários/química
18.
J Prosthet Dent ; 131(5): 969.e1-969.e7, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38443241

RESUMO

STATEMENT OF PROBLEM: Research on the color and translucency properties of 3-dimensionally (3D) printed definitive resins and the effect of coffee thermocycling on these properties is lacking. PURPOSE: The purpose of this in vitro study was to investigate the effect of coffee thermocycling on the color and translucency parameters of the milled and 3D printed materials used for definitive restorations. MATERIAL AND METHODS: Plate-shaped specimens (12×12×1 mm) of 3 milled (IPS e.max CAD (LDS), Vita Enamic (PICN), Cerasmart (RNC)) and two 3D printed (VarseoSmile Crownplus (VSP), Permanent Crown (PC)) were fabricated (n=12). The brightness (L*), red-green (a*), and yellow-blue (b*) parameters were measured with a spectrophotometer before and after 10 000 coffee thermocycles. The relative translucency parameters (RTP00) and color change were calculated using the CIEDE2000 formula. Stainability (ΔE00) and translucency differences (ΔRTP00) were evaluated. Data were analyzed with the Kruskal-Wallis, Mann-Whitney U, and Wilcoxon tests. The Spearman correlation test was used to analyze the ΔE00 and ΔRTP00 values (α=.05). RESULTS: The type of material and coffee thermocycling significantly affected the evaluated parameters at both measurement periods (P=.001). Coffee thermocycling decreased the L* and RTP00 values while increasing the a* and b* values (P=.001). The highest ΔE00 values were found in VSP and PC, which were statistically similar (P=.291), while the highest | ΔRTP00 | values were observed for VSP (P=.001). The lowest ΔE00 and | ΔRTP00 | values were found in LDS (P=.001). A positive relationship was found between the ΔE00 and | ΔRTP00| values (R=.590, P=.01). CONCLUSIONS: After coffee thermocycling, all tested materials exhibited a darkened, yellowish, and opaque appearance, although the alterations in color and translucency remained within clinically acceptable thresholds (AT00=1.81) for these materials.


Assuntos
Café , Cor , Impressão Tridimensional , Materiais Dentários/química , Humanos , Teste de Materiais , Coroas , Técnicas In Vitro , Espectrofotometria
19.
J Dent ; 144: 104941, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38490323

RESUMO

OBJECTIVES: To evaluate how restoration thickness (0.5 mm and 0.7 mm) affects the fabrication trueness of additively manufactured definitive resin-based laminate veneers, and to analyze the effect of restoration thickness and margin location on margin quality. METHODS: Two maxillary central incisors were prepared either for a 0.5 mm- or 0.7 mm-thick laminate veneer. After acquiring the partial-arch scans of each preparation, laminate veneers were designed and stored as reference data. By using these reference data, a total of 30 resin-based laminate veneers were additively manufactured (n = 15 per thickness). All veneers were digitized and stored as test data. The reference and test data were superimposed to calculate the root mean square values at overall, external, intaglio, and marginal surfaces. The margin quality at labial, incisal, mesial, and distal surfaces was evaluated. Fabrication trueness at each surface was analyzed with independent t-tests, while 2-way analysis of variance was used to analyze the effect of thickness and margin location on margin quality (α = 0.05). RESULTS: Regardless of the evaluated surface, 0.7 mm-thick veneers had lower deviations (P < 0.001). Only the margin location (P < 0.001) affected the margin quality as labial margins had the lowest quality (P < 0.001). CONCLUSION: Restoration thickness affected the fabrication trueness of resin-based laminate veneers as 0.7 mm-thick veneers had significantly higher trueness. However, restoration thickness did not affect the margin quality and labial margins had the lowest quality. CLINICAL SIGNIFICANCE: Laminate veneers fabricated by using tested urethane-based acrylic resin may require less adjustment when fabricated in 0.7 mm thickness. However, marginal integrity issues may be encountered at the labial surface.


Assuntos
Resinas Compostas , Adaptação Marginal Dentária , Materiais Dentários , Facetas Dentárias , Incisivo , Propriedades de Superfície , Humanos , Materiais Dentários/química , Resinas Compostas/química , Teste de Materiais , Planejamento de Prótese Dentária , Porcelana Dentária/química , Desenho Assistido por Computador , Cerâmica/química , Poliuretanos/química , Metacrilatos/química
20.
J Dent ; 144: 104936, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38492806

RESUMO

OBJECTIVE: To evaluate the three-dimensional (3D) stability and accuracy of additively manufactured surgical templates fabricated using two different 3D printers and materials. MATERIALS AND METHODS: Forty surgical templates were designed and printed using two different 3D printers: the resin group (n = 20) used a digital light processing (DLP) 3D printer with photopolymer resin, and the metal group (n = 20) employed a selective laser melting (SLM) 3D printer with titanium alloy. All surgical templates were scanned immediately after production and re-digitalized after one month of storage. Similarly, the implant simulations were performed twice. Three-dimensional congruency between the original design and the manufactured surgical templates was quantified using the root mean square (RMS), and the definitive and planned implant positions were determined and compared. RESULTS: At the postproduction stage, the metal templates exhibited higher accuracy than the resin templates (p < 0.001), and these differences persisted after one month of storage (p < 0.001). The resin templates demonstrated a significant decrease in three-dimensional stability after one month of storage (p < 0.001), whereas the metal templates were not affected (p > 0.05). No significant differences in implant accuracy were found between the two groups. However, the resin templates showed a significant increase in apical and angular deviations after one month of storage (p < 0.001), whereas the metal templates were not affected (p > 0.05). CONCLUSION: Printed metal templates showed higher fabrication accuracy than printed resin templates. The three-dimensional stability and implant accuracy of printed metal templates remained unaffected by one month of storage. CLINICAL SIGNIFICANCE: With superior three-dimensional stability and acceptable implant accuracy, printed metal templates can be considered a viable alternative technique for guided surgery.


Assuntos
Impressão Tridimensional , Titânio , Humanos , Titânio/química , Desenho Assistido por Computador , Lasers , Implantes Dentários , Ligas/química , Imageamento Tridimensional/métodos , Implantação Dentária Endóssea/instrumentação , Implantação Dentária Endóssea/métodos , Materiais Dentários/química , Ligas Dentárias/química , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA