Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30.371
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Luminescence ; 39(5): e4775, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38745525

RESUMO

A new smartphone-based chemiluminescence method has been introduced for the quantitative analysis of CL-20 (Hexanitroazaisowuertzitan) explosive. The solvent mixture, oxidizer agent, and concentration of the reactants were optimized using statistical procedures. CL-20 explosive showed a quenching effect on the chemiluminescence intensity of the luminol-NaClO reaction in the solvent mixture of DMSO/H2O. A smartphone was used as a detector to record the light intensity of chemiluminescence reaction as a video file. The recorded video file was converted to an analytical signal as intensity luminescence-time curve by a written code in MATLAB software. Dynamic range and limit of detection of the proposed method were obtained 2.0-240.0 and 1.1 mg⋅L-1, respectively, in optimized concentrations 1.5 × 10-3 mol⋅L-1 luminol and 1.0 × 10-2 mol⋅L-1 NaClO. Precursors TADB, HBIW, and TADNIW in CL-20 explosive synthesis did not show interference in measurement the CL-20 purity. The analysis of CL-20 spiked samples of soil and water indicated the satisfactory ability of the method in the analysis of real samples. The interaction of CL-20 molecules and OCl- ions is due to quench of chemiluminescence reaction of the luminol-NaClO.


Assuntos
Medições Luminescentes , Luminol , Smartphone , Medições Luminescentes/métodos , Medições Luminescentes/instrumentação , Luminol/química , Substâncias Explosivas/análise , Luminescência , Limite de Detecção
2.
Luminescence ; 39(5): e4750, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38733198

RESUMO

Ultra-high thermally stable Ca2MgWO6:xSm3+ (x = 0.5, 0.75, 1, 1.25, and 1.5 mol%) double perovskite phosphors were synthesized through solid-state reaction method. Product formation was confirmed by comparing the X-ray diffraction (XRD) patterns of the phosphors with the standard reference file. The structural, morphological, thermal, and optical properties of the prepared phosphor were examined in detail using XRD, Fourier transform infrared spectra, scanning electron microscopy, diffused reflectance spectra, thermogravimetric analysis (TGA), photoluminescence emission, and temperature-dependent PLE (TDPL). It was seen that the phosphor exhibited emission in the reddish region for the near-ultraviolet excitation with moderate Colour Rendering Index values and high colour purity. The optimized phosphor (x = 1.25 mol%) was found to possess a direct optical band gap of 3.31 eV. TGA studies showed the astonishing thermal stability of the optimized phosphor. Additionally, near-zero thermal quenching was seen in TDPL due to elevated phonon-assisted radiative transition. Furthermore, the anti-Stokes and Stokes emission peaks were found to be sensitive toward the temperature change and followed a Boltzmann-type distribution. All these marked properties will make the prepared phosphors a suitable candidate for multifield applications and a fascinating material for further development.


Assuntos
Luminescência , Substâncias Luminescentes , Samário , Temperatura , Compostos de Tungstênio , Compostos de Tungstênio/química , Substâncias Luminescentes/química , Substâncias Luminescentes/síntese química , Samário/química , Medições Luminescentes , Difração de Raios X , Compostos de Cálcio/química , Óxidos/química , Termogravimetria
3.
Anal Chem ; 96(19): 7516-7523, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38691765

RESUMO

Herein, single-atom iron doped carbon dots (SA Fe-CDs) were successfully prepared as novel electrochemiluminescence (ECL) emitters with high ECL efficiency, and a biosensor was constructed to ultrasensitively detect microRNA-222 (miRNA-222). Importantly, compared with the conventional without single-atom doped CDs with low ECL efficiency, SA Fe-CDs exhibited strong ECL efficiency, in which single-atom iron as an advanced coreactant accelerator could significantly enhance the generation of reactive oxygen species (ROS) from the coreactant S2O82- for improving the ECL efficiency. Moreover, a neoteric amplification strategy combining the improved strand displacement amplification with Nt.BbvCI enzyme-induced target amplification (ISDA-EITA) could produce 4 output DNAs in every cycle, which greatly improved the amplification efficiency. Thus, a useful ECL biosensor was built with a detection limit of 16.60 aM in the range of 100 aM to 1 nM for detecting traces of miRNA-222. In addition, miRNA-222 in cancer cell lysate (MHCC-97L) was successfully detected by using the ECL biosensor. Therefore, this strategy provides highly efficient single-atom doped ECL emitters for the construction of sensitive ECL biosensing platforms in the biological field and clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Carbono , Técnicas Eletroquímicas , Ferro , Medições Luminescentes , MicroRNAs , Pontos Quânticos , MicroRNAs/análise , Carbono/química , Ferro/química , Técnicas Eletroquímicas/métodos , Pontos Quânticos/química , Humanos , Técnicas Biossensoriais/métodos , Limite de Detecção
4.
Anal Chim Acta ; 1309: 342677, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38772666

RESUMO

BACKGROUND: Rapid and sensitive detection for acetamiprid, a kind of widely used neonicotinoid insecticide, is very meaningful for the development of modern agriculture and the protection of human health. Highly stable electrochemiluminescence (ECL) materials are one of the key factors in ECL sensing technology. ECL materials prepared by porous materials (e.g., MOFs) coated with chromophores have been used for ECL sensing detection, but these materials have poor stability because the chromophores escape when they are in aqueous solution. Therefore, the development of highly stable ECL materials is of great significance to improve the sensitivity of ECL sensing technology. RESULTS: In this work, by combining etched metal-organic frameworks (E-UIO-66-NH2) as carrier with Tris(4,4'-dicarboxylic acid-2,2'-bipyridine)Ru(II) chloride (Ru(dcbpy)32+) as signal probe via amide bonds, highly stable nanocomposites (E-UIO-66-NH2-Ru) with excellent ECL performance were firstly prepared. Then, using MoS2 loaded with AuNPs as substrate material and co-reactant promoter, a signal off-on-off ECL aptamer sensor was prepared for sensitive detection of acetamiprid. Due to the excellent catalytic activity of E-UIO-66-NH2-Ru and MoS2@Au towards K2S2O8, the ECL signals can be enhanced by multiple signal enhancement pathways, the prepared ECL aptamer sensor could achieve sensitive detection of acetamiprid in the linear range of 10-13 to10-7 mol L-1, with the limit of detection (LOD) of 2.78ⅹ10-15 mol L-1 (S/N = 3). After the evaluation of actual sample testing, this sensing platform was proven to be an effective method for the detection of acetamiprid in food and agricultural products. SIGNIFICANCE AND NOVELTY: The E-UIO-66-NH2-Ru prepared by linking Ru(dcbpy)32+ to E-UIO-66-NH2 via amide bonding has very high stability. The synergistic catalytic effect of MoS2 and AuNPs enhanced the ECL signal. By exploring the sensing mechanism and evaluating the actual sample tests, the proposed signal "on-off" ECL sensing strategy was proved to be an effective and excellent ECL sensing method for sensitive and stable detection of acetamiprid.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Eletroquímicas , Medições Luminescentes , Estruturas Metalorgânicas , Neonicotinoides , Neonicotinoides/análise , Técnicas Eletroquímicas/métodos , Aptâmeros de Nucleotídeos/química , Medições Luminescentes/métodos , Estruturas Metalorgânicas/química , Rutênio/química , Técnicas Biossensoriais/métodos , Limite de Detecção , Complexos de Coordenação/química , Inseticidas/análise
5.
Anal Chim Acta ; 1309: 342646, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38772670

RESUMO

BACKGROUND: Colorimetric lateral flow immunoassay (LFIA) is a widely used point-of-care testing (POCT) technology, while it has entered a bottleneck period because of low detection sensitivity, expensive preparation materials, and incapable quantitative detection. Therefore, it is necessary to develop a novel POCT method that is ultrasensitive, simple, portable, and capable of accurately detecting biomarkers in biofluids daily, particularly for pregnancy preparation and early screening of diseases. RESULT: In this work, a novel dry chemistry-based self-enhanced electrochemiluminescence (DC-SE-ECL) LFIA sensor is introduced for accurate POCT of luteinizing hormone (LH). The proposed DC-SE-ECL immunosensor significantly improves the detection sensitivity through the Poly-l-Lysine (PLL)-based SE-ECL probe and cathode modification of closed bipolar electrode (C-BPE). Additionally, a new type of C-BPE configuration is designed for easily performing the LFIA. And, two standalone absorbent pads are symmetrically arranged below the reporting channel of the electrode pad to decease useless residues on the detection pad, which further improves the detection performance. Under optimized conditions, the proposed LFIA sensor has a low limit of detection (9.274 µIU mL-1) and a wide linear dynamic range (0.01-100 mIU mL-1), together with good selectivity, repeatability and storage stability. SIGNIFICANCE: These results indicate that the proposed DC-SE-ECL method has the potential as a new tool for detecting biomarkers in clinical samples.


Assuntos
Técnicas Eletroquímicas , Medições Luminescentes , Hormônio Luteinizante , Hormônio Luteinizante/análise , Hormônio Luteinizante/sangue , Humanos , Imunoensaio/métodos , Técnicas Eletroquímicas/instrumentação , Limite de Detecção , Eletrodos , Técnicas Biossensoriais
6.
BMC Biotechnol ; 24(1): 30, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38720310

RESUMO

BACKGROUND: Venous thromboembolism (VTE), is a noteworthy complication in individuals with gastric cancer, but the current diagnosis and treatment methods lack accuracy. In this study, we developed a t-PAIC chemiluminescence kit and employed chemiluminescence to detect the tissue plasminogen activator inhibitor complex (t-PAIC), thrombin-antithrombin III complex (TAT), plasmin-α2-plasmin inhibitor complex (PIC) and thrombomodulin (TM), combined with D-dimer and fibrin degradation products (FDP), to investigate their diagnostic potential for venous thrombosis in gastric cancer patients. The study assessed variations in six indicators among gastric cancer patients at different stages. RESULTS: The t-PAIC reagent showed LOD is 1.2 ng/mL and a linear factor R greater than 0.99. The reagents demonstrated accurate results, with all accuracy deviations being within 5%. The intra-batch and inter-batch CVs for the t-PAIC reagent were both within 8%. The correlation coefficient R between this method and Sysmex was 0.979. Gastric cancer patients exhibited elevated levels of TAT, PIC, TM, D-D, FDP compared to the healthy population, while no significant difference was observed in t-PAIC. In the staging of gastric cancer, patients in III-IV stages exhibit higher levels of the six markers compared to those in I-II stages. The ROC curve indicates an enhancement in sensitivity and specificity of the combined diagnosis of four or six indicators. CONCLUSION: Our chemiluminescence assay performs comparably to Sysmex's method and at a reduced cost. The use of multiple markers, including t-PAIC, TM, TAT, PIC, D-D, and FDP, is superior to the use of single markers for diagnosing VTE in patients with malignant tumors. Gastric cancer patients should be screened for the six markers to facilitate proactive prophylaxis, determine the most appropriate treatment timing, ameliorate their prognosis, decrease the occurrence of venous thrombosis and mortality, and extend their survival.


Assuntos
Medições Luminescentes , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico , Masculino , Pessoa de Meia-Idade , Medições Luminescentes/métodos , Feminino , Idoso , Antitrombina III/metabolismo , Antitrombina III/análise , Trombomodulina/sangue , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , alfa 2-Antiplasmina/metabolismo , alfa 2-Antiplasmina/análise , Adulto , Fibrinolisina/metabolismo , Fibrinolisina/análise , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/sangue , Peptídeo Hidrolases
7.
ACS Chem Biol ; 19(5): 1035-1039, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38717306

RESUMO

Red-shifted bioluminescence is highly desirable for diagnostic and imaging applications. Herein, we report a semisynthetic NanoLuc (sNLuc) based on complementation of a split NLuc (LgBiT) with a synthetic peptide (SmBiT) functionalized with a fluorophore for BRET emission. We observed exceptional BRET ratios with diverse fluorophores, notably in the red (I674/I450 > 14), with a brightness that is sufficient for naked eye detection in blood or through tissues. To exemplify its utility, LgBiT was fused to a miniprotein that binds HER2 (affibody, ZHER2), and the selective detection of HER2+ SK-BR-3 cells over HER2- HeLa cells was demonstrated.


Assuntos
Medições Luminescentes , Humanos , Células HeLa , Medições Luminescentes/métodos , Luciferases/genética , Luciferases/metabolismo , Receptor ErbB-2/metabolismo , Linhagem Celular Tumoral , Corantes Fluorescentes/química
8.
Luminescence ; 39(5): e4776, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38769690

RESUMO

The purpose of the work was to find optimal conditions for bioluminescent enzymatic analysis of saliva (based on the use of NADH:FMN oxidoreductase + luciferase) and then to determine the biological effect of using bioluminescence assay of saliva to study the physiological state of the body under normal and pathological conditions. The saliva of snowboarders and students were studied in the "rest-training" model. The saliva of patients diagnosed with acute pharyngitis was examined in the "sick-healthy" model. Bioluminescence assay was performed with a lyophilized and immobilized bi-enzyme system using cuvette, plate, and portable luminometers. The concentrations of secretory immunoglobulin A (sIgA) and cortisol were determined by enzyme immunoassay, and the total protein content was measured by spectrophotometric method. The activity of the bioluminescent system enzymes increased as the amount and volume of saliva in the sample was decreased. The cuvette and plate luminometers were sensitive to changes in the luminescence intensity in saliva assay. Luminescence intensity correlated with the concentrations of sIgA and cortisol. The integrated bioluminescent index for saliva was reduced in the "rest-training" model and increased in the "sick-healthy" model. Thus, the non-invasive bioluminescent saliva analysis may be a promising tool for assessing the health of the population.


Assuntos
Medições Luminescentes , Saliva , Humanos , Saliva/enzimologia , Saliva/química , Medições Luminescentes/métodos , Bioensaio , Hidrocortisona/análise , Hidrocortisona/metabolismo , Luciferases/metabolismo , Luciferases/química , Imunoglobulina A Secretora/análise , Imunoglobulina A Secretora/metabolismo
9.
Anal Chim Acta ; 1307: 342641, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719418

RESUMO

The article details a groundbreaking platform for detecting microRNAs (miRNAs), crucial biomolecules involved in gene regulation and linked to various diseases. This innovative platform combines the CRISPR-Cas13a system's precise ability to specifically target and cleave RNA molecules with the amplification capabilities of the hybridization chain reaction (HCR). HCR aids in signal enhancement by creating branched DNA structures. Additionally, the platform employs electrochemiluminescence (ECL) for detection, noted for its high sensitivity and low background noise, making it particularly effective. A key application of this technology is in the detection of miR-17, a biomarker associated with multiple cancer types. It exhibits remarkable detection capabilities, characterized by low detection limits (14.38 aM) and high specificity. Furthermore, the platform's ability to distinguish between similar miRNA sequences and accurately quantify miR-17 in cell lysates underscores its significant potential in clinical and biomedical fields. This combination of precise targeting, signal amplification, and sensitive detection positions the platform as a powerful tool for miRNA analysis in medical diagnostics and research.


Assuntos
Sistemas CRISPR-Cas , Técnicas Eletroquímicas , Medições Luminescentes , MicroRNAs , Hibridização de Ácido Nucleico , MicroRNAs/análise , MicroRNAs/genética , Humanos , Sistemas CRISPR-Cas/genética , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Limite de Detecção
10.
Biosens Bioelectron ; 258: 116351, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38705074

RESUMO

Multifunctional single-atom catalysts (SACs) have been extensively investigated as outstanding signal amplifiers in bioanalysis field. Herein, a type of Fe single-atom catalysts with Fe-nitrogen coordination sites in nitrogen-doped carbon (Fe-N/C SACs) was synthesized and demonstrated to possess both catalase and peroxidase-like activity. Utilizing Fe-N/C SACs as dual signal amplifier, an efficient bipolar electrode (BPE)-based electrochemiluminescence (ECL) immunoassay was presented for determination of prostate-specific antigen (PSA). The cathode pole of the BPE-ECL platform modified with Fe-N/C SACs is served as the sensing side and luminol at the anode as signal output side. Fe-N/C SACs could catalyze decomposition of H2O2 via their high catalase-like activity and then increase the Faraday current, which can boost the ECL of luminol due to the electroneutrality in a closed BPE system. Meanwhile, in the presence of the target, glucose oxidase (GOx)-Au NPs-Ab2 was introduced through specific immunoreaction, which catalyzes the formation of H2O2. Subsequently, Fe-N/C SACs with peroxidase-like activity catalyze the reaction of H2O2 and 4-chloro-1-naphthol (4-CN) to generate insoluble precipitates, which hinders electron transfer and then inhibits the ECL at the anode. Thus, dual signal amplification of Fe-N/C SACs was achieved by increasing the initial ECL and inhibiting the ECL in the presence of target. The assay exhibits sensitive detection of PSA linearly from 1.0 pg/mL to 100 ng/mL with a detection limit of 0.62 pg/mL. The work demonstrated a new ECL enhancement strategy of SACs via BPE system and expands the application of SACs in bioanalysis field.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Eletrodos , Peróxido de Hidrogênio , Ferro , Limite de Detecção , Medições Luminescentes , Luminol , Antígeno Prostático Específico , Catálise , Medições Luminescentes/métodos , Técnicas Eletroquímicas/métodos , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Humanos , Luminol/química , Antígeno Prostático Específico/análise , Antígeno Prostático Específico/sangue , Ferro/química , Glucose Oxidase/química , Imunoensaio/métodos , Ouro/química , Peroxidase/química , Nanopartículas Metálicas/química , Nitrogênio/química , Carbono/química , Naftóis
11.
Biosens Bioelectron ; 258: 116356, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38705073

RESUMO

In this work, the dual-ligand lanthanide metal-organic framework (MOF)-based electrochemiluminescence (ECL) sensor was constructed for the detection of miRNA-128 in glioblastoma (GBM) diagnosis. The luminescent Eu-MOF (EuBBN) was synthesized with terephthalic acid (BDC) and 2-amino terephthalic acid (BDC-NH2) as dual-ligand. Due to the antenna effect, EuBBN with conjugated-π structure exhibited strong luminescent signal and high quantum efficiency, which can be employed as ECL nanoprobe. Furthermore, the novel plasmonic CuS@Au heterostructure array has been prepared. The localized surface plasmon resonance coupling effect of the CuS@Au heterostructure array can amplify the ECL signal of EuBBN significantly. The EuBBN/CuS@Au heterostructure array-based sensing system has been prepared for the detection of miRNA-128 with a wide linear range from 1 fM to 1 nM and a detection limit of 0.24 fM. Finally, miRNA-128 in the clinic GBM tissue sample has been analysis for the distinguish of tumor grade successfully. The results demonstrated that the dual-ligand MOF/CuS@Au heterostructure array-based ECL sensor can provide important support for the development of GBM diagnosis.


Assuntos
Técnicas Biossensoriais , Európio , Glioblastoma , Ouro , Estruturas Metalorgânicas , MicroRNAs , MicroRNAs/análise , Glioblastoma/diagnóstico , Humanos , Estruturas Metalorgânicas/química , Técnicas Biossensoriais/métodos , Ouro/química , Európio/química , Limite de Detecção , Medições Luminescentes/métodos , Ligantes , Técnicas Eletroquímicas/métodos , Neoplasias Encefálicas/diagnóstico , Ácidos Ftálicos/química , Nanopartículas Metálicas/química , Cobre/química
12.
Luminescence ; 39(5): e4762, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38698695

RESUMO

Broadband near-infrared (NIR) spectroscopy has gained significant attention due to its versatile application in various fields. In the realm of NIR phosphors, Fe3+ ion is an excellent activator known for its nontoxic and harmless nature. In this study, we prepared an Fe3+-activated SrGa12O19 (SGO) NIR phosphor and analyzed its phase and luminescence properties. Upon excitation at 326 nm, the SGO:Fe3+ phosphor exhibited a broadband emission in the range 700-1000 nm, peaking at 816 nm. The optical band gap of SGO:Fe3+ was evaluated. To enhance the long-lasting phosphorescence, an oxygen vacancy-rich SGO:Fe3+ (VO-SGO:Fe3+) sample was prepared for activation. Interestingly, the increase in the oxygen-vacancy concentration indeed contributed to the activation of persistent luminescence of Fe3+ ions. The VO-SGO:Fe3+ sample has a long duration and high charge storage capacity, allowing it to perform efficiently in various applications. This work provides the foundation for further design of Cr3+-free PersL phosphors with efficient NIR PersL.


Assuntos
Luminescência , Substâncias Luminescentes , Oxigênio , Oxigênio/química , Substâncias Luminescentes/química , Estrôncio/química , Medições Luminescentes , Compostos Férricos/química , Gálio/química , Ferro/química , Espectroscopia de Luz Próxima ao Infravermelho
13.
Anal Chim Acta ; 1306: 342585, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692786

RESUMO

Herein, we developed a convenient and versatile dual-mode electrochemiluminescence (ECL) and photoelectrochemistry (PEC) sensing radar for the detection of Prostate-specific antigen (PSA), which has important implications for detection of low-abundance disease-associated proteins. Cerium-based metal-organic framework (Ce-MOFs) were firstly modified on the electrode, showing well ECL and PEC property. In particular, a unique multifunctional Au@CdS quantum dots (QDs) probe loaded numerous QDs and antibody was fabricated, not only displaying strong ECL and PEC signals, but also having specific recognition to PSA. After the signal probe was linked to the electrode by immune reaction, much amplified signals of ECL and PEC were generated for double-mode detection of PSA. Therefore, this work proposed a multifunctional Au@CdS QDs signal probe with excellent ECL and PEC performance, and developed an ultrasensitive photoelectric biosensing platform for dual-mode detection, which provides an effective method for health monitoring of cancer patients.


Assuntos
Compostos de Cádmio , Técnicas Eletroquímicas , Estruturas Metalorgânicas , Antígeno Prostático Específico , Pontos Quânticos , Sulfetos , Pontos Quânticos/química , Compostos de Cádmio/química , Sulfetos/química , Humanos , Antígeno Prostático Específico/análise , Antígeno Prostático Específico/sangue , Estruturas Metalorgânicas/química , Ouro/química , Cério/química , Técnicas Biossensoriais , Processos Fotoquímicos , Limite de Detecção , Eletrodos , Medições Luminescentes
14.
Luminescence ; 39(5): e4759, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38693721

RESUMO

Colloidal semiconductor quantum dots have many potential optical applications, including quantum dot light-emitting diodes, single-photon sources, or biological luminescent markers. The optical properties of colloidal quantum dots can be affected by their dielectric environment. This study investigated the photoluminescence (PL) decay of thick-shell gradient-alloyed colloidal semiconductor quantum dots as a function of solvent refractive index. These measurements were conducted in a wide range of delay times to account for both the initial spontaneous decay of excitons and the delayed emission of excitons that has the form of a power law. It is shown that whereas the initial spontaneous PL decay is very sensitive to the refractive index of the solvent, the power-law delayed emission of excitons is not. Our results seem to exclude the possibility of carrier self-trapping in the considered solvents and suggest the existence of trap states inside the quantum dots. Finally, our data show that the average exciton lifetime significantly decreases as a function of the solvent refractive index. The change in exciton lifetime is qualitatively modeled and discussed.


Assuntos
Coloides , Luminescência , Pontos Quânticos , Solventes , Pontos Quânticos/química , Solventes/química , Coloides/química , Refratometria , Medições Luminescentes , Semicondutores , Fatores de Tempo
15.
Luminescence ; 39(5): e4757, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38712382

RESUMO

The orange luminescence of α-Al2O3 under UV excitation is characterized by a 2.07-eV orange broadband emission that has not yet been elucidated. This emission is present in natural and synthetic crystals and powders, as well as in Be-treated samples. All orange-luminescent materials have low Fe concentration (mostly <1000 ppm) with traces of divalent cations, mostly Mg, or Be in Be-diffused material (dozens of ppm). Mg2+, Mn2+, and Be2+ cations substitute for trivalent Al. To accommodate the charge deficit, several defects are created, including oxygen vacancies also called F centers. Indeed, our excitation spectra revealed the presence of several different F centers (F, F+, and clustered F2, F2 +, F2 2+) in those samples. However, the thermal stability and the measured luminescence lifetimes do not match with previously reported characteristics of isolated F centers. Based on our experiments, we suggest that a complex aggregate of two F centers (F2 2+) trapped at divalent cations is a major cause of this uncommon microsecond lifetime emission, even if a variety of other defects, including Cr3+, V3+, or interstitial Al3+, are present.


Assuntos
Óxido de Alumínio , Luminescência , Óxido de Alumínio/química , Cátions Bivalentes/química , Medições Luminescentes
16.
J Am Chem Soc ; 146(19): 13406-13416, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38698549

RESUMO

Bioluminescent indicators are power tools for studying dynamic biological processes. In this study, we present the generation of novel bioluminescent indicators by modifying the luciferin molecule with an analyte-binding moiety. Specifically, we have successfully developed the first bioluminescent indicator for potassium ions (K+), which are critical electrolytes in biological systems. Our approach involved the design and synthesis of a K+-binding luciferin named potassiorin. Additionally, we engineered a luciferase enzyme called BRIPO (bioluminescent red indicator for potassium) to work synergistically with potassiorin, resulting in optimized K+-dependent bioluminescence responses. Through extensive validation in cell lines, primary neurons, and live mice, we demonstrated the efficacy of this new tool for detecting K+. Our research demonstrates an innovative concept of incorporating sensory moieties into luciferins to modulate luciferase activity. This approach has great potential for developing a wide range of bioluminescent indicators, advancing bioluminescence imaging (BLI), and enabling the study of various analytes in biological systems.


Assuntos
Luciferases , Medições Luminescentes , Potássio , Potássio/metabolismo , Potássio/química , Animais , Medições Luminescentes/métodos , Camundongos , Luciferases/química , Luciferases/metabolismo , Humanos , Engenharia de Proteínas , Substâncias Luminescentes/química , Luciferina de Vaga-Lumes/química , Luciferina de Vaga-Lumes/metabolismo
17.
Anal Chem ; 96(19): 7763-7771, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38699865

RESUMO

Given its pivotal role in modulating various pathological processes, precise measurement of nitric oxide (●NO) levels in physiological solutions is imperative. The key techniques include the ozone-based chemiluminescence (CL) reactions, amperometric ●NO sensing, and Griess assay, each with its advantages and drawbacks. In this study, a hemin/H2O2/luminol CL reaction was employed for accurately detecting ●NO in diverse solutions. We investigated how the luminescence kinetics was influenced by ●NO from two donors, nitrite and peroxynitrite, while also assessing the impact of culture medium components and reactive species quenchers. Furthermore, we experimentally and theoretically explored the mechanism of hemin oxidation responsible for the initiation of light generation. Although both hemin and ●NO enhanced the H2O2/luminol-based luminescence reactions with distinct kinetics, hemin's interference with ●NO/peroxynitrite- modulated their individual effects. Leveraging the propagated signal due to hemin, the ●NO levels in solution were estimated, observing parallel changes to those detected via amperometric detection in response to varying concentrations of the ●NO-donor. The examined reactions aid in comprehending the mechanism of ●NO/hemin/H2O2/luminol interactions and how these can be used for detecting ●NO in solution with minimal sample size demands. Moreover, the selectivity across different solutions can be improved by incorporating certain quenchers for reactive species into the reaction.


Assuntos
Hemina , Peróxido de Hidrogênio , Óxido Nítrico , Hemina/química , Óxido Nítrico/análise , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Sondas Moleculares/química , Luminol/química , Soluções , Medições Luminescentes , Ácido Peroxinitroso/análise , Ácido Peroxinitroso/química , Cinética , Oxirredução
18.
Anal Chem ; 96(19): 7643-7650, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38708712

RESUMO

Chemiluminescence (CL), especially commercialized CL immunoassay (CLIA), is normally performed within the eye-visible region of the spectrum by exploiting the electronic-transition-related emission of the molecule luminophore. Herein, dual-stabilizers-capped CdTe nanocrystals (NCs) is employed as a model of nanoparticulated luminophore to finely tune the CL color with superior color purity. Initialized by oxidizing the CdTe NCs with potassium periodate (KIO4), intermediates of the reactive oxygen species (ROS) tend to charge CdTe NCs in both series-connection and parallel-connection routes and dominate the charge-transfer CL of CdTe NCs. The CdTe NCs/KIO4 system can exhibit color-tunable CL with the maximum emission wavelength shifted from 694 nm to 801 nm, and the red-shift span is over 100 nm. Both PL and CL of each of the CdTe NCs are bandgap-engineered; the change in the NCs surface state via CL reaction enables CL of each of the CdTe NCs to be red-shifted for ∼20 nm to PL, while the change in the NCs surface state via labeling CdTe NCs to secondary-antibody (Ab2) enables CL of the CdTe NCs-Ab2 conjugates to be red-shifted for another ∼20 nm to bare CdTe NCs. The CL of CdTe753-Ab2/KIO4 is ∼791 nm, which can perform near-infrared CL immunoassay and semi-automatically determined procalcitonin (PCT) on commercialized in vitro diagnosis (IVD) instruments.


Assuntos
Compostos de Cádmio , Medições Luminescentes , Nanopartículas , Telúrio , Telúrio/química , Imunoensaio/métodos , Compostos de Cádmio/química , Nanopartículas/química , Cor , Luminescência , Automação , Humanos
19.
Luminescence ; 39(5): e4755, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38689564

RESUMO

The ultimate goal of this work is the study of the effect of luminescence stimulations and signals reading modes combinations on the thermoluminescence intensity and glow curve behaviour for the same X-ray irradiation dose. Three interesting stimulating and reading modes are considered, namely, infrared stimulated luminescence (IRSL), blue light-emitting diode stimulated luminescence (BLSL) and thermally stimulated luminescence (TSL). The studied stimulation and reading modes combination protocols are (Protocol 1) IRSL-TSL, (Protocol 2) IRSL-BLSL-TSL and (Protocol 3) BLSL-IRSL-TSL. Experiments are performed on beryllium oxide (BeO) dosimeter. Results demonstrate well that the combination of reading modes have direct impact on the TL signal in terms of intensity and glow curve shape. It was also found that when reading modes are correctly combined, particularly when IRSL is applied first, then BLSL and TL, it is possible to collect two or more exploitable signals of different stimulation types for the same irradiation that can be used for different purposes and final applications.


Assuntos
Berílio , Dosimetria Termoluminescente , Berílio/química , Luminescência , Raios Infravermelhos , Medições Luminescentes , Temperatura
20.
Methods Mol Biol ; 2797: 125-143, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38570457

RESUMO

Various biochemical methods have been introduced to detect and characterize KRAS activity and interactions, from which the vast majority is based on luminescence detection in its varying forms. Among these methods, thermal stability assays, using luminophore-conjugated proteins or external environment sensing dyes, are widely used. In this chapter, we describe methods enabling KRAS stability monitoring in vitro, with an emphasis on ligand-induced stability. This chapter focuses mainly on luminescence-based techniques utilizing external dye molecules and fluorescence detection.


Assuntos
Luminescência , Proteínas Proto-Oncogênicas p21(ras) , Proteínas Proto-Oncogênicas p21(ras)/genética , Proteínas/química , Medições Luminescentes , Corantes Fluorescentes/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA