Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.953
Filtrar
1.
Molecules ; 29(9)2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38731472

RESUMO

Alzheimer's disease (AD) is a progressive neurodegenerative disease characterized by the accumulation of amyloid beta (Aß) plaques in the brain. Aß1-42 is the main component of Aß plaque, which is toxic to neuronal cells. Si nanowires (Si NWs) have the advantages of small particle size, high specific surface area, and good biocompatibility, and have potential application prospects in suppressing Aß aggregation. In this study, we employed the vapor-liquid-solid (VLS) growth mechanism to grow Si NWs using Au nanoparticles as catalysts in a plasma-enhanced chemical vapor deposition (PECVD) system. Subsequently, these Si NWs were transferred to a phosphoric acid buffer solution (PBS). We found that Si NWs significantly reduced cell death in PC12 cells (rat adrenal pheochromocytoma cells) induced by Aß1-42 oligomers via double staining with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and fluorescein diacetate/propyl iodide (FDA/PI). Most importantly, pre-incubated Si NWs largely prevented Aß1-42 oligomer-induced PC12 cell death, suggesting that Si NWs exerts an anti-Aß neuroprotective effect by inhibiting Aß aggregation. The analysis of Fourier Transform Infrared (FTIR) results demonstrates that Si NWs reduce the toxicity of fibrils and oligomers by intervening in the formation of ß-sheet structures, thereby protecting the viability of nerve cells. Our findings suggest that Si NWs may be a potential therapeutic agent for AD by protecting neuronal cells from the toxicity of Aß1-42.


Assuntos
Peptídeos beta-Amiloides , Nanofios , Silício , Peptídeos beta-Amiloides/toxicidade , Peptídeos beta-Amiloides/metabolismo , Peptídeos beta-Amiloides/antagonistas & inibidores , Nanofios/química , Animais , Células PC12 , Ratos , Silício/química , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/toxicidade , Fragmentos de Peptídeos/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Fármacos Neuroprotetores/farmacologia , Fármacos Neuroprotetores/química , Agregados Proteicos/efeitos dos fármacos , Doença de Alzheimer/tratamento farmacológico , Doença de Alzheimer/metabolismo
2.
ACS Appl Mater Interfaces ; 16(19): 24410-24420, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38709954

RESUMO

Sonophotodynamic antimicrobial therapy (SPDAT) is recognized as a highly efficient biomedical treatment option, known for its versatility and remarkable healing outcomes. Nevertheless, there is a scarcity of sonophotosensitizers that demonstrate both low cytotoxicity and exceptional antibacterial effectiveness in clinical applications. In this paper, a novel ZnO nanowires (NWs)@TiO2-xNy core-sheath composite was developed, which integrates the piezoelectric effect and heterojunction to build dual built-in electric fields. Remarkably, it showed superb antibacterial effectiveness (achieving 95% within 60 min against S. aureus and ∼100% within 40 min against E. coli, respectively) when exposed to visible light and ultrasound. Due to the continuous interference caused by light and ultrasound, the material's electrostatic equilibrium gets disrupted. The modification in electrical properties facilitates the composite's ability to attract bacterial cells through electrostatic forces. Moreover, Zn-O-Ti and Zn-N-Ti bonds formed at the interface of ZnO NWs@TiO2-xNy, further enhancing the dual internal electric fields to accelerate the excited carrier separation to generate more reactive oxygen species (ROS), and thereby boosting the antimicrobial performance. In addition, the TiO2 layer limited Zn2+ dissolution into solution, leading to good biocompatibility and low cytotoxicity. Lastly, we suggest a mechanistic model to offer practical direction for the future development of antibacterial agents that are both low in toxicity and high in efficacy. In comparison to the traditional photodynamic therapy systems, ZnO NWs@TiO2-xNy composites exhibit super piezo-photocatalytic antibacterial activity with low toxicity, which shows great potential for clinical application as an antibacterial nanomaterial.


Assuntos
Antibacterianos , Escherichia coli , Nanofios , Staphylococcus aureus , Titânio , Óxido de Zinco , Titânio/química , Titânio/farmacologia , Titânio/efeitos da radiação , Óxido de Zinco/química , Óxido de Zinco/farmacologia , Antibacterianos/química , Antibacterianos/farmacologia , Escherichia coli/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Nanofios/química , Catálise , Espécies Reativas de Oxigênio/metabolismo , Testes de Sensibilidade Microbiana , Humanos , Luz , Camundongos , Animais
3.
Nat Commun ; 15(1): 3902, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724527

RESUMO

Radiation-induced in situ tumor vaccination alone is very weak and insufficient to elicit robust antitumor immune responses. In this work, we address this issue by developing chiral vidarabine monophosphate-gadolinium nanowires (aAGd-NWs) through coordination-driven self-assembly. We elucidate the mechanism of aAGd-NW assembly and characterize their distinct features, which include a negative surface charge, ultrafine topography, and right-handed chirality. Additionally, aAGd-NWs not only enhance X-ray deposition but also inhibit DNA repair, thereby enhancing radiation-induced in situ vaccination. Consequently, the in situ vaccination induced by aAGd-NWs sensitizes radiation enhances CD8+ T-cell-dependent antitumor immunity and synergistically potentiates the efficacy immune checkpoint blockade therapies against both primary and metastatic tumors. The well-established aAGd-NWs exhibit exceptional therapeutic capacity and biocompatibility, offering a promising avenue for the development of radioimmunotherapy approaches.


Assuntos
Nanofios , Polímeros , Nanofios/química , Animais , Camundongos , Polímeros/química , Linhagem Celular Tumoral , Gadolínio/química , Gadolínio/farmacologia , Camundongos Endogâmicos C57BL , Linfócitos T CD8-Positivos/imunologia , Linfócitos T CD8-Positivos/efeitos dos fármacos , Vacinas Anticâncer/imunologia , Feminino , Humanos , Vacinação/métodos , Neoplasias/imunologia
4.
Int J Mol Sci ; 25(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732092

RESUMO

In this work, we apply single-molecule fluorescence microscopy and spectroscopy to probe plasmon-enhanced fluorescence and Förster resonance energy transfer in a nanoscale assemblies. The structure where the interplay between these two processes was present consists of photoactive proteins conjugated with silver nanowires and deposited on a monolayer graphene. By comparing the results of continuous-wave and time-resolved fluorescence microscopy acquired for this structure with those obtained for the reference samples, where proteins were coupled with either a graphene monolayer or silver nanowires, we find clear indications of the interplay between plasmonic enhancement and the energy transfer to graphene. Namely, fluorescence intensities calculated for the structure, where proteins were coupled to graphene only, are less than for the structure playing the central role in this study, containing both silver nanowires and graphene. Conversely, decay times extracted for the latter are shorter compared to a protein-silver nanowire conjugate, pointing towards emergence of the energy transfer. Overall, the results show that monitoring the optical properties of single emitters in a precisely designed hybrid nanostructure provides an elegant way to probe even complex combination of interactions at the nanoscale.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Grafite , Nanofios , Prata , Prata/química , Nanofios/química , Grafite/química , Transferência Ressonante de Energia de Fluorescência/métodos , Corantes Fluorescentes/química , Proteínas/química , Microscopia de Fluorescência/métodos , Imagem Individual de Molécula/métodos
5.
Anal Chem ; 96(19): 7470-7478, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38696229

RESUMO

MicroRNAs (miRNAs) are endogenous and noncoding single-stranded RNA molecules with a length of approximately 18-25 nucleotides, which play an undeniable role in early cancer screening. Therefore, it is very important to develop an ultrasensitive and highly specific method for detecting miRNAs. Here, we present a bottom-up assembly approach for modifying glass microtubes with silica nanowires (SiNWs) and develop a label-free sensing platform for miRNA-21 detection. The three-dimensional (3D) networks formed by SiNWs make them abundant and highly accessible sites for binding with peptide nucleic acid (PNA). As a receptor, PNA has no phosphate groups and exhibits an overall electrically neutral state, resulting in a relatively small repulsion between PNA and RNA, which can improve the hybridization efficiency. The SiNWs-filled glass microtube (SiNWs@GMT) sensor enables ultrasensitive, label-free detection of miRNA-21 with a detection limit as low as 1 aM at a detection range of 1 aM-100 nM. Noteworthy, the sensor can still detect miRNA-21 in the range of 102-108 fM in complex solutions containing 1000-fold homologous interference of miRNAs. The high anti-interference performance of the sensor enables it to specifically recognize target miRNA-21 in the presence of other miRNAs and distinguish 1-, 3-mismatch nucleotide sequences. Significantly, the sensor platform is able to detect miRNA-21 in the lysate of breast cancer cell lines (e.g., MCF-7 cells and MDA-MB-231 cells), indicating that it has good potential in the screening of early breast cancers.


Assuntos
Vidro , MicroRNAs , Nanofios , Ácidos Nucleicos Peptídicos , Dióxido de Silício , MicroRNAs/análise , Ácidos Nucleicos Peptídicos/química , Dióxido de Silício/química , Humanos , Nanofios/química , Vidro/química , Técnicas Biossensoriais/métodos , Limite de Detecção
6.
ACS Appl Mater Interfaces ; 16(20): 26943-26953, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38718354

RESUMO

The continuous, noninvasive monitoring of human blood pressure (BP) through the accurate detection of pulse waves has extremely stringent requirements on the sensitivity and stability of flexible strain sensors. In this study, a new ultrasensitive flexible strain sensor based on the interlayer synergistic effect was fabricated through drop-casting and drying silver nanowires and graphene films on polydimethylsiloxane substrates and was further successfully applied for continuous monitoring of BP. This strain sensor exhibited ultrahigh sensitivity with a maximum gauge factor of 34357.2 (∼700% sensitivity enhancement over other major sensors), satisfactory response time (∼85 ms), wide strange range (12%), and excellent stability. An interlayer fracture mechanism was proposed to elucidate the working principle of the strain sensor. The real-time BP values can be obtained by analyzing the relationship between the BP and the pulse transit time. To verify our strain sensor for real-time BP monitoring, our strain sensor was compared with a conventional electrocardiogram-photoplethysmograph method and a commercial cuff-based device and showed similar measurement results to BP values from both methods, with only minor differences of 0.693, 0.073, and 0.566 mmHg in the systolic BP, diastolic BP, and mean arterial pressure, respectively. Furthermore, the reliability of the strain sensors was validated by testing 20 human subjects for more than 50 min. This ultrasensitive strain sensor provides a new pathway for continuous and noninvasive BP monitoring.


Assuntos
Nanofios , Prata , Humanos , Nanofios/química , Prata/química , Pressão Sanguínea/fisiologia , Grafite/química , Determinação da Pressão Arterial/instrumentação , Determinação da Pressão Arterial/métodos , Masculino , Dimetilpolisiloxanos/química , Nanoestruturas/química , Adulto
7.
J Environ Manage ; 359: 121045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38703653

RESUMO

A multifunctional Ag/AlOOH nanowires (ANW) composite substrate was constructed, which not only accomplishes highly sensitive detection of organic dye molecules, but also has excellent performance in the degradation of pollutants. The ANW in the Ag/ANW substrate possesses a high aspect ratio, which extends the distribution area of Ag and enables a large number of hot spots on the active substrate. Additionally, due to the abundant OH groups on the ANW, there is an increased number of anchor sites for adsorbed metal ions in the Ag/ANW compound, thus contributing to the enhancement and degradation of molecules. Moreover, the constructed multifunctional Ag/ANW nanocomplexes also show great promise for practical applications, providing a reference for the detection and degradation of contaminants.


Assuntos
Nanofios , Análise Espectral Raman , Nanofios/química , Prata/química , Compostos Orgânicos/química , Compostos Orgânicos/análise
8.
Anal Chim Acta ; 1306: 342613, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38692794

RESUMO

Glucose detection is of significant importance in providing information to the human health management. However, conventional enzymatic glucose sensors suffer from a limited long-term stability due to the losing activity of the enzymes. In this work, the AuNi bimetallic aerogel with a well-defined nanowire network is synthesized and applied as the sensing nanomaterial in the non-enzymatic glucose detection. The three-dimensional (3D) hierarchical porous structure of the AuNi bimetallic aerogel ensures the high sensitivity of the sensor (40.34 µA mM-1 cm-2). Theoretical investigation unveiled the mechanism of the boosting electrocatalytic activity of the AuNi bimetallic aerogel toward glucose. A better adhesion between the sensing nanomaterial and the screen-printing electrodes (SPEs) is obtained after the introduction of Ni. On the basis of a wide linearity in the range of 0.1-5 mM, an excellent selectivity, an outstanding long-term stability (90 days) as well as the help of the signal processing circuit and an M5stack development board, the as-prepared glucose sensor successfully realizes remote monitoring of the glucose concentration. We speculate that this work is favorable to motivating the technological innovations of the non-enzymatic glucose sensors and intelligent sensing devices.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Géis , Glucose , Ouro , Níquel , Técnicas Biossensoriais/métodos , Níquel/química , Géis/química , Ouro/química , Glucose/análise , Eletrodos , Nanofios/química , Humanos , Limite de Detecção
9.
ACS Appl Mater Interfaces ; 16(19): 24341-24350, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38687629

RESUMO

Magnetic micro/nanorobots are promising platforms for targeted drug delivery, and their construction with soft and flexible features has received extensive attention for practical applications. Despite significant efforts in this field, facile fabrication of magnetic microrobots with flexible structures and versatility in targeted therapy remains a big challenge. Herein, we proposed a novel universal strategy to fabricate a biohybrid flexible sperm-like microrobot (BFSM) based on a Chlorella (Ch.) cell and artificial flagella, which showed great potential for targeted chemo-photothermal therapy for the first time. In this approach, microspherical Ch. cells were utilized to construct the microrobotic heads, which were intracellularly deposited with core-shell Pd@Au, extracellularly magnetized with Fe3O4, and further loaded with anticancer drug. The magnetic heads with excellent photothermal and chemotherapeutic capability were further assembled with flexible polypyrrole nanowires via biotin-streptavidin bonding to construct the BFSMs. Based on the exquisite head-to-tail structures, the BFSMs could be effectively propelled under precessing magnetic fields and move back and forth without a U-turn. Moreover, in vitro chemo-photothermal tests were conducted to verify their performance of targeted drug delivery toward localized HeLa cells. Due to this superior versatility and facile fabrication, the BFSMs demonstrated great potential for targeted anticancer therapy.


Assuntos
Terapia Fototérmica , Humanos , Células HeLa , Robótica , Sistemas de Liberação de Medicamentos , Antineoplásicos/química , Antineoplásicos/farmacologia , Doxorrubicina/química , Doxorrubicina/farmacologia , Polímeros/química , Nanofios/química , Ouro/química
10.
Nanotechnology ; 35(32)2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38648780

RESUMO

Flexible piezoresistive pressure sensors are gaining significant attention, particularly in the realm of flexible wearable electronic skin. Here, a flexible piezoresistive pressure sensor was developed with a broad sensing range and high sensitivity. We achieved this by curing polydimethylsiloxane (PDMS) on sandpaper, creating a PDMS film as the template with a micro-protrusion structure. The core sensing layer was formed using a composite of silver nanowires (AgNWs) and waterborne polyurethane (WPU) with a similar micro-protrusion structure. The sensor stands out with its exceptional sensitivity, showing a value of 1.04 × 106kPa-1with a wide linear range from 0 to 27 kPa. It also boasts a swift response and recovery time of 160 ms, coupled with a low detection threshold of 17 Pa. Even after undergoing more than 1000 cycles, the sensor continues to deliver stable performance. The flexible piezoresistive pressure sensor based on AgNWs/WPU composite film (AWCF) can detect small pressure changes such as pulse, swallowing, etc, which indicates that the sensor has great application potential in monitoring human movement and flexible wearable electronic skin.


Assuntos
Dimetilpolisiloxanos , Nanofios , Poliuretanos , Pressão , Prata , Dispositivos Eletrônicos Vestíveis , Poliuretanos/química , Nanofios/química , Prata/química , Humanos , Dimetilpolisiloxanos/química , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento
11.
ACS Sens ; 9(4): 1896-1905, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38626402

RESUMO

With the escalating global awareness of air quality management, the need for continuous and reliable monitoring of toxic gases by using low-power operating systems has become increasingly important. One of which, semiconductor metal oxide gas sensors have received great attention due to their high/fast response and simple working mechanism. More specifically, self-heating metal oxide gas sensors, wherein direct thermal activation in the sensing material, have been sought for their low power-consuming characteristics. However, previous works have neglected to address the temperature distribution within the sensing material, resulting in inefficient gas response and prolonged response/recovery times, particularly due to the low-temperature regions. Here, we present a unique metal/metal oxide/metal (MMOM) nanowire architecture that conductively confines heat to the sensing material, achieving high uniformity in the temperature distribution. The proposed structure enables uniform thermal activation within the sensing material, allowing the sensor to efficiently react with the toxic gas. As a result, the proposed MMOM gas sensor showed significantly enhanced gas response (from 6.7 to 20.1% at 30 ppm), response time (from 195 to 17 s at 30 ppm), and limit of detection (∼1 ppm) when compared to those of conventional single-material structures upon exposure to carbon monoxide. Furthermore, the proposed work demonstrated low power consumption (2.36 mW) and high thermal durability (1500 on/off cycles), demonstrating its potential for practical applications in reliable and low-power operating gas sensor systems. These results propose a new paradigm for power-efficient and robust self-heating metal oxide gas sensors with potential implications for other fields requiring thermal engineering.


Assuntos
Gases , Nanofios , Óxidos , Nanofios/química , Gases/química , Gases/análise , Óxidos/química , Metais/química
12.
ACS Sens ; 9(4): 2050-2056, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38632929

RESUMO

DNA carries genetic information and can serve as an important biomarker for the early diagnosis and assessment of the disease prognosis. Here, we propose a bottom-up assembly method for a silica nanowire-filled glass microporous (SiNWs@GMP) sensor and develop a universal sensing platform for the ultrasensitive and specific detection of DNA. The three-dimensional network structure formed by SiNWs provides them with highly abundant and accessible binding sites, allowing for the immobilization of a large amount of capture probe DNA, thereby enabling more target DNA to hybridize with the capture probe DNA to improve detection performance. Therefore, the SiNWs@GMP sensor achieves ultrasensitive detection of target DNA. In the detection range of 1 aM to 100 fM, there is a good linear relationship between the decrease rate of current signal and the concentration of target DNA, and the detection limit is as low as 1 aM. The developed SiNWs@GMP sensor can distinguish target DNA sequences that are 1-, 3-, and 5-mismatched, and specifically recognize target DNA from complex mixed solution. Furthermore, based on this excellent selectivity and specificity, we validate the universality of this sensing strategy by detecting DNA (H1N1 and H5N1) sequences associated with the avian influenza virus. By replacing the types of nucleic acid aptamers, it is expected to achieve a wide range and low detection limit sensitive detection of various biological molecules. The results indicate that the developed universal sensing platform has ultrahigh sensitivity, excellent selectivity, stability, and acceptable reproducibility, demonstrating its potential application in DNA bioanalysis.


Assuntos
Técnicas Biossensoriais , Vidro , Limite de Detecção , Nanofios , Dióxido de Silício , Vidro/química , Dióxido de Silício/química , Nanofios/química , Técnicas Biossensoriais/métodos , DNA/química , Porosidade , Virus da Influenza A Subtipo H5N1 , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , DNA Viral/análise , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação
13.
Bioelectrochemistry ; 158: 108702, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38669976

RESUMO

The residue of lincomycin in water will not only aggravate the drug resistance of bacteria but also cause damage to the human body through biological accumulation. In this work, an electrochemiluminescence (ECL) aptasensor for the detection of lincomycin was constructed based on polydimethyldiallylammonium chloride (PDDA) functionalized Ce-doped TbPO4 nanowires (PDDA-TbPO4:Ce NWs) and silver nanoparticles (Ag NPs). TbPO4:Ce NWs were used as the luminophore, and PDDA was used to functionalize the luminophore to make the surface of the luminophore positively charged. The negatively charged silver nanoparticles were combined with PDDA-TbPO4:Ce NWs by electrostatic interaction. Ag NPs accelerated the electron transfer rate and promoted the ECL efficiency, which finally increased the ECL intensity of TbPO4:Ce NWs by about 4 times. Under the optimal conditions, the detection limit of the ECL sensor was as low as 4.37 × 10-16 M, and the linear range was 1 × 10 - 15 M to 1 × 10 - 5 M, with good selectivity, stability, and repeatability. The sensor can be applied to the detection of lincomycin in water, and the recovery rate is 97.7-103.4 %, which has broad application prospects.


Assuntos
Técnicas Eletroquímicas , Limite de Detecção , Lincomicina , Medições Luminescentes , Nanopartículas Metálicas , Prata , Lincomicina/análise , Prata/química , Medições Luminescentes/métodos , Nanopartículas Metálicas/química , Técnicas Eletroquímicas/métodos , Poluentes Químicos da Água/análise , Nanofios/química , Técnicas Biossensoriais/métodos , Compostos de Amônio Quaternário/química
14.
Int J Biol Macromol ; 266(Pt 2): 130977, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513893

RESUMO

Compared to conventional bandages, which do not meet all wound care requirements, nanofiber wound dressings could provide a potentially excellent environment for healing. In the present research, nanocomposite membrane based on starch (St) - polyvinyl alcohol (PVA) nanofibers containing ciprofloxacin antibiotic drug loaded on graphene oxide­silver nanowire (GO-AgNWs) hybrid nanoparticles is produced by electrospinning process. Morphological studies showed that the length and diameter of silver nanowires are 21 ± 9.17 µm and 82 ± 10.52 nm, respectively. The contact angle of 57.1° due to the hydrophilic nature of nanofibers, also the swelling degree of 679.51 % and, the water vapor permeability of 2627 ± 56 (g/m2.day) can be expressed as a confirmation of the ability of this wound dressing to manage secretions around the wound. In evaluating the antibacterial activity of these nanocomposite membranes against Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus bacteria, the most potent antibacterial effect is in the case of nanofibers containing a high percentage of starch and nanoparticles carrying ciprofloxacin; with non-growth halos of 47.58 mm and 22.06 mm was recorded. The release of ciprofloxacin drug in vitro was reported to be 61.69 % during 24 h, and the final release rate was 82.17 %. Despite the biocompatibility and cell viability of 97.74 % and the biodegradability rate of 28.51 %, the StP-GOAgNWCip nanocomposite membrane can be introduced as a suitable candidate for wound dressing.


Assuntos
Antibacterianos , Bandagens , Ciprofloxacina , Preparações de Ação Retardada , Grafite , Nanocompostos , Álcool de Polivinil , Prata , Amido , Ciprofloxacina/química , Ciprofloxacina/farmacologia , Ciprofloxacina/administração & dosagem , Nanocompostos/química , Amido/química , Álcool de Polivinil/química , Grafite/química , Prata/química , Antibacterianos/farmacologia , Antibacterianos/química , Liberação Controlada de Fármacos , Staphylococcus aureus/efeitos dos fármacos , Escherichia coli/efeitos dos fármacos , Nanofios/química , Cicatrização/efeitos dos fármacos , Nanofibras/química , Humanos , Testes de Sensibilidade Microbiana , Portadores de Fármacos/química
15.
Biosensors (Basel) ; 14(3)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38534249

RESUMO

Silicon nanowire field effect (SiNW-FET) biosensors have been successfully used in the detection of nucleic acids, proteins and other molecules owing to their advantages of ultra-high sensitivity, high specificity, and label-free and immediate response. However, the presence of the Debye shielding effect in semiconductor devices severely reduces their detection sensitivity. In this paper, a three-dimensional stacked silicon nanosheet FET (3D-SiNS-FET) biosensor was studied for the high-sensitivity detection of nucleic acids. Based on the mainstream Gate-All-Around (GAA) fenestration process, a three-dimensional stacked structure with an 8 nm cavity spacing was designed and prepared, allowing modification of probe molecules within the stacked cavities. Furthermore, the advantage of the three-dimensional space can realize the upper and lower complementary detection, which can overcome the Debye shielding effect and realize high-sensitivity Point of Care Testing (POCT) at high ionic strength. The experimental results show that the minimum detection limit for 12-base DNA (4 nM) at 1 × PBS is less than 10 zM, and at a high concentration of 1 µM DNA, the sensitivity of the 3D-SiNS-FET is approximately 10 times higher than that of the planar devices. This indicates that our device provides distinct advantages for detection, showing promise for future biosensor applications in clinical settings.


Assuntos
Técnicas Biossensoriais , Nanofios , Ácidos Nucleicos , Silício/química , Transistores Eletrônicos , DNA , Técnicas Biossensoriais/métodos , Nanofios/química
16.
Environ Res ; 249: 118410, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38342204

RESUMO

With widespread and excessive use of antibiotics in medicine, poultry farming, and aquaculture, antibiotic residues have become a significant threat to both eco-environment and human health. In this paper, using hydroxyapatite nanowires (HApNWs) as an ecologically compatible carrier, a novel nano-hammer shaped conjunction with HApNW conjugating CuO microspheres (CuO@HApNWs) was successfully synthesized by in-situ agglomeration method. The catalytic degradation performance of the nano-hammer shaped CuO@HApNWs with Fenton-like activation was investigated by using tetracycline (TC) as a representative antibiotic pollutant. Remarkably, it exhibited excellent catalytic activity, which the removal rate of TC got to 92.0% within 40 min, and the pseudo-second-order reaction kinetic constant was 18.33 × 10-3 L mg-1·min-1, which was 26 times and 5 times than that of HApNWs and CuO, respectively. Furthermore, after recycling 6 times, the degradation efficiency of TC still remained above 85 %. Based on radical scavenger tests and electron paramagnetic resonance (EPR) spectroscopy, it demonstrated that the excellent activity of CuO@HApNWs was mainly attributed to the fact that Fenton-like activation promotes the circulation of Cu2+ and Cu+, the generated main active oxygen species (•OH and O2-•) achieve efficient degradation of TC. In summary, the nano-hammer shaped CuO@HApNWs could be in-situ synthesed, and used as an eco-friendly Fenton-like catalyst for effectively catalytic degradation of organic pollutants, which has great potential for wastewater treatment.


Assuntos
Antibacterianos , Cobre , Nanofios , Tetraciclina , Poluentes Químicos da Água , Cobre/química , Tetraciclina/química , Catálise , Antibacterianos/química , Nanofios/química , Poluentes Químicos da Água/química , Durapatita/química
17.
Talanta ; 272: 125772, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38367400

RESUMO

Hydrogen peroxide (H2O2) is a biomarker relevant for oxidative stress monitoring. Most chronic airway diseases are characterized by increased oxidative stress. To date, the main methods for the detection of this analyte are expensive and time-consuming laboratory techniques such as fluorometric and colorimetric assays. There is a growing interest in the development of electrochemical sensors for H2O2 detection due to their low cost, ease of use, sensitivity and rapid response. In this work, an electrochemical sensor based on gold nanowire arrays has been developed. Thanks to the catalytic activity of gold against hydrogen peroxide reduction and the high surface area of nanowires, this sensor allows the quantification of this analyte in a fast, efficient and selective way. The sensor was obtained by template electrodeposition and consists of gold nanowires about 5 µm high and with an average diameter of about 200 nm. The high active surface area of this electrode, about 7 times larger than a planar gold electrode, ensured a high sensitivity of the sensor (0.98 µA µM-1cm-2). The sensor allows the quantification of hydrogen peroxide in the range from 10 µM to 10 mM with a limit of detection of 3.2 µM. The sensor has excellent properties in terms of reproducibility, repeatability and selectivity. The sensor was validated by quantifying the hydrogen peroxide released by human airways A549 cells exposed or not to the pro-oxidant compound rotenone. The obtained results were validated by comparing them with those obtained by flow cytometry after staining the cells with the fluorescent superoxide-sensitive Mitosox Red probe giving a very good concordance.


Assuntos
Peróxido de Hidrogênio , Nanofios , Humanos , Peróxido de Hidrogênio/química , Nanofios/química , Ouro/química , Reprodutibilidade dos Testes , Técnicas Eletroquímicas/métodos , Células Epiteliais , Eletrodos
18.
Bioelectrochemistry ; 157: 108664, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38330529

RESUMO

Metal doping plays a key role in overcoming inefficient extracellular electron transfer between electrode interface and electricity-producing microorganisms. However, it is unknown whether different metals play distinctive roles in the doping process. Herein, three different metal ions (Fe, Ni and Cu) are added to the spinning precursor to obtain the corresponding electrospinning metal doped carbon nanofibers. It is found that the maximum output power of iron doped carbon nanofiber anode is 641.96 mW m-2, which is better than that of nickel doped carbon nanofiber (411.26 mW m-2) and copper doped carbon nanofiber (336.01 mW m-2), as well as 7.62 times higher than that of CNF. The results proved that due to the various number and types of active sites formed, as well as the distinction in surface morphology and structure, the electronegativity of each material is different. The different bio-abiotic interface could affect the direct contact between the anode interface and the extracellular protein of electricity producing microorganisms, which leading to a significant gap in the improvement of bioelectrocatalytic performance of different metal anode materials. This work provides a synthetic idea for designing highly efficient anode materials with directional metal modification and interface regulation.


Assuntos
Nanofios , Nanofios/química , Carbono/química , Eletricidade , Cobre , Ferro
19.
ACS Sens ; 9(3): 1525-1532, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38377562

RESUMO

Peptides with distinct physiochemical properties and biocompatibility hold significant promise across diverse domains including antifouling biosensors. However, the stability of natural antifouling peptides in physiological conditions poses significant challenges to their viability for sustained practical applications. Herein, a unique antifouling peptide FFFGGGEKEKEKEK was designed and self-assembled to form peptide nanoparticles (PNPs), which possessed enhanced stability against enzymatic hydrolysis in biological fluids. The PNP-coated interfaces exhibited superior stability and antifouling properties in preventing adsorption of nonspecific materials, such as proteins and cells in biological samples. Moreover, a highly sensitive and ultralow fouling electrochemical biosensor was developed through the immobilization of the PNPs and specific aptamers onto the polyaniline nanowire-modified electrode, achieving the biomarker carcinoembryonic antigen detection in complex biofluids with reliable accuracy. This research not only addresses the challenge of the poor proteolytic resistance observed in natural peptides but also introduces a universal strategy for constructing ultralow fouling sensing devices.


Assuntos
Incrustação Biológica , Técnicas Biossensoriais , Nanopartículas , Nanofios , Incrustação Biológica/prevenção & controle , Peptídeos/química , Nanofios/química
20.
Biosensors (Basel) ; 14(2)2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38391984

RESUMO

Field-effect transistor (FET)-based biosensors are powerful analytical tools for detecting trace-specific biomolecules in diverse sample matrices, especially in the realms of pandemics and infectious diseases. The primary concern in applying these biosensors is their stability, a factor directly impacting the accuracy and reliability of sensing over extended durations. The risk of biosensor degradation is substantial, potentially jeopardizing the sensitivity and selectivity and leading to inaccurate readings, including the possibility of false positives or negatives. This paper delves into the documented degradation of silicon nanobelt FET (NBFET) biosensors induced by buffer solutions. The results highlight a positive correlation between immersion time and the threshold voltage of NBFET devices. Secondary ion mass spectrometry analysis demonstrates a gradual increase in sodium and potassium ion concentrations within the silicon as immersion days progress. This outcome is ascribed to the nanobelt's exposure to the buffer solution during the biosensing period, enabling ion penetration from the buffer into the silicon. This study emphasizes the critical need to address buffer-solution-induced degradation to ensure the long-term stability and performance of FET-based biosensors in practical applications.


Assuntos
Técnicas Biossensoriais , Nanofios , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Nanofios/química , Reprodutibilidade dos Testes , Silício/química , Transistores Eletrônicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA